DCS Series
1000-3000 WATTS PROGRAMMABLE DC SUPPLY
Features
•
•
•
•
High power density
Remote voltage sense & remote programming
Wide range of output voltages
High programming resolution with ethernet
interface
•
Remote control
Specifications
INPUT
Input voltage
OPERATING
Efficiency
See table
1KW: 200-250VAC, single phase; 100-132VAC
single phase, internal jumper selectable (see M1
option) 1.2KW: 200-250VAC, single phase; 100-
132VAC single phase, internal jumper selectable
(see M1 option) 3KW: 190-250VAC, three phase;
200-250VAC, single phase (Note: Max.power
output of 3KW supplies must be limited to 2.5KW
for single phase input)
Remote sense
The maximum allowed sense line drop is 4V per line
(2V on the DCS 8 and 10V 1KW and 1.2KW models
and 1V/ line for all 3KW models)
Remote programming
Overvoltage protection
External jumper via rear panel connectors J3.
Crowbar type adjustable from 5-110% Protection
rated output using front panel control (local or
remote program selectable via J3 jumper)
Frequency
Current
47-63Hz for both single and three phase input
Remote analog
programming
Linearity: +/-1%
Accuracy: +/-5%
1KW: 15A typ at 115VAC, 8A typ at 230VAC,
1.2KW: 18A typ at 115VAC, 9A typ at 230VAC,
3KW: 20A typ at 230VAC single phase, 14A typ at
230VAC three phase
Software
LabVIEW® driver for M9C/M85 (Contact Powerbox)
Regulatory compliance
CE Mark on all models, FCC Part 15 Class A UL1012
and CSA 22.2 #220 (1 and 1.2 KW only)
Soft start
Line current is lower than full load peak value
during turn-on or power application after restart
ENVIRONMENTAL
Operating temperature
Storage temperature
Humidity range
Options and Accessories
0°C to 50° (No De-rating)
-40°C to 85°C
INPUT VOLTAGE OPTIONS
M1
Factory configured for 115VAC input (1 and 1.2kW only)
0-80% RH, non condensing
Internal fan with over-temperature protection
REMOTE INTERFACE OPTIONS
Cooling
M9C
M13
M32
Internal IEEE-488/RS 232 interface
Locking shafts (front panel potentiometers)
Master/slave cable configured for two or more units
Replace input connector with terminal block (3kW only)
OUTPUT
Voltage adjustment
Current adjustment
Ripple & Noise
Zero to rated output
Zero to rated output
See table
M33
M51A
Isolated analog programming control of
V/I/OVP and isolated V/I monitor outputs up to
500V relative to the supply’s return line
Regulation (Line or Load) Voltage: 0.1% Current: 0.1%
M85
Multichannel slave interface
M102
Front panel binding posts for 1kw or 1.2
kW, Models ꢁ30A, ꢁ100V. Not compatible with
M9C, M85, M130, M131, M133, M135, M136
LXI compliant 10/100 Base T Ethernet
remote control master interface; includes web
server for direct control of power supply via web
browser (MS Internet Explorer 6.0 or later)
Transient response
Stability
Typically recovers in < 1ms to 1% of steady-state
output voltage (within 1% of Vmax) for 70-100%
or 100-70% load change. 500ꢀs typical
M130
+/-0.05% of maximum voltage or current over 8
hours after 30 minute warm-up time at fixed line,
load and temperature
Temperature Coefficient
0.02%/°C of maximum output voltage 0.03%/°C of
maximum output current
M131
M133
16-bit slave interface option for use with a
M130 master (3 ft. control cable included)
Output disconnect and polarity reversal
controlled via SCPI commands. Limited to 1k or
1.2 kW, ꢁ 300V, ꢁ 60A
M135
M130 & M133 combination
M131 & M133 combination
Rack slide kit (3kW)
M136
105-330-26
484
DCS Series
1000-3000 WATTS PROGRAMMABLE DC SUPPLY
PROGRAMMING
CONSTANTS CURRENT
MODE
TEMP.
INPUT CURRENT, A
NORMAL
CONSTANT CURRENT MODE*
CASE
VOLTAGE
DRIFT % %
COEFF.
VOLTAGE
%/°C
EFFICIENCY
% (TYP)
MODEL
I
MAX
COMBINED
RIPPLE
230V
SINGLE
PHASE
208V
THREE
PHASE
O
REGULATION LINE
OHMS/A
V/A
(TYP)
(RMS)
(TYP)
AND LOAD %
DCS 8-140E
DCS 10-120E
DCS 20-60E
DCS 33-36E
DCS 40-30E
DCS 50-24E
DCS 60-20E
DCS 80-15E
DCS 100-12E
DCS 150-8E
DCS 300-4E
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
180
153
30
11
9
8.5
6.6
6
3.6
2.3
1.2
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
35.7
41.7
83.3
138.9
166.7
208.3
250
333.3
416.7
625
9
9
9
9
9
9
9
9
9
9
9
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
82
82
82
84
84
84
85
85
85
85
85
I
I
I
I
I
I
I
I
I
I
I
0-10V= 0-100%
I
or
o
0-5V= 0-100%
I
o
1250
* Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory
Dimension: 1RU or 44mm (H) x 482mm (W) x 444mm (D) ; Weight: 8.6kg86
DSC 3kW Series
PROGRAMMING CONSTANTS
VOLTAGE MODES
TEMP.
OUTPUT POWER
CONSTANT VOLTAGE MODE*
COMBINED
REGULATION
LINE AND
VOLTAGE
DRIFT %
VMAX
(TYP)
COEFF.
RIPPLE NOISE TRANSIENT VOLTAGE
MODEL
CURRENT
VOLTAGE
ADC @
(RMS)**
(TYP.)
(P-P) RESPONSE
(TYP) TIME (TYP)
%/°C
(TYP)
OHMS/V
V/V
LOAD %
VDC
50°C
DCS 8-350E
DCS 12-250E
DCS 20-150E
DCS 40-75E
DCS 55-55E
DCS 60-50E
DCS 80-37E
DCS 150-20E
0-8
0-12
0-20
0-40
0-55
0-60
0-80
0-150
0-350
0-250
0-150
0-75
0-55
0-50
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
15mV
10mV
10mV
20mV
20mV
20mV
20mV
30mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
200mV
1000s
1000s
1000s
1000s
1000s
1000s
1000s
1000s
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
625
416.7
250
125
90.9
83
0-10V = 0-100% V
or
o
0-5V = 0-100% V
o
0-37
0-20
62.5
33.3
PROGRAMMING
CONSTANTS CURRENT
MODE
TEMP.
INPUT CURRENT, A
NORMAL
CONSTANT CURRENT MODE*
CASE
VOLTAGE
COEFF.
VOLTAGE
%/°C
DRIFT % %
MAX
EFFICIENCY
% (TYP)
MODEL
I
COMBINED
RIPPLE
230V
SINGLE
PHASE
208V
THREE
PHASE
O
REGULATION LINE
AND LOAD %
OHMS/A
V/A
(TYP)
(RMS)
(TYP)
DCS 8-350E
DCS 12-250E
DCS 20-150E
DCS 40-75E
DCS 55-55E
DCS 60-50E
DCS 80-37E
DCS 150-20E
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
870
400
100
75
40
33
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
14.7
20
24
26
26
26
26
26
26
26
13
14
14
14
14
14
14
14
82
82
82
86
82
86
86
86
II
II
II
II
II
II
II
II
33.3
66.7
90.9
100
135
250
0-10V= 0-100% I0
or
0-5V= 0-100% I0
20
10
* Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory
Dimension: 2RU or 88mm (H) x 482mm (W) x 444mm (D) ; Weight: 15kg
486
DCS Series
1000-3000 WATTS PROGRAMMABLE DC SUPPLY
DSC 1kW Series
PROGRAMMING CONSTANTS
VOLTAGE MODES
TEMP.
COEFF.
OUTPUT POWER
CONSTANT VOLTAGE MODE*
COMBINED
REGULATION
LINE AND
VOLTAGE
DRIFT %
VMAX
MODEL
CURRENT
NOISE TRANSIENT VOLTAGE
VOLTAGE
ADC @
VDC
RIPPLE
(P-P) RESPONSE
(TYP) TIME (TYP)
%/°C
(TYP)
OHMS/V
V/V
LOAD %
(TYP)
(RMS)** (TYP.)
50°C
DCS 8-125E
DCS 10-100E
DCS 20-50E
DCS 33-33E
DCS 40-25E
DCS 50-20E
DCS 60-18E
DCS 80-13E
DCS 100-10E
DCS 150-7E
DCS 300-3.5E
DCS 600-1.7E
0-8
0-10
0-20
0-33
0-40
0-50
0-60
0-80
0-100
0-150
0-300
0-600
0-125
0-100
0-50
0-33
0-25
0-20
0-18
0-13
0-10
0-7
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
4mV
4mV
4mV
4mV
4mV
4mV
4mV
4mV
6mV
12mV
20mV
50mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
160mV
200mV
300mV
500s
500s
500s
500s
500s
500s
500s
500s
500s
500s
500s
500s
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
625
500
250
151.5
125
100
83
62.5
50
33.3
16.67
8.33
0-10V = 0-100%
V
or
o
0-5V = 0-100% V
o
0-3.5
0-1.7
PROGRAMMING
CONSTANTS CURRENT
MODE
TEMP.
INPUT CURRENT, A
NORMAL
CONSTANT CURRENT MODE*
CASE
VOLTAGE
DRIFT % %
COEFF.
VOLTAGE
%/°C
EFFICIENCY
% (TYP)
MODEL
I
MAX
COMBINED
RIPPLE
230V
SINGLE
PHASE
208V
THREE
PHASE
O
REGULATION LINE
OHMS/A
V/A
(TYP)
(RMS)
(TYP)
AND LOAD %
DCS 8-125E
DCS 10-100E
DCS 20-50E
DCS 33-33E
DCS 40-25E
DCS 50-20E
DCS 60-18E
DCS 80-13E
DCS 100-10E
DCS 150-7E
DCS 300-3.5E
DCS 600-1.7E
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
160
128
25
10
7
7
6
4
3
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.03
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
40
50
100
151.5
200
250
277.8
384.6
500
714.3
1428.6
2941.2
8
8
8
8
8
8
8
8
8
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
82
82
82
84
84
84
86
86
86
86
86
86
I
I
I
I
I
I
I
I
0-10V= 0-100%
I
or
o
0-5V= 0-100% I
o
I
I
I
2
1
1
8
8
9.5
***
* Typical resolution is 0.02% **RMS ripple from 20Hz to 300kHz ***Consult factory
Dimension: 1RU or 44mm (H) x 482mm (W) x 444mm (D) ; Weight: 8.6kg
DSC 1.2kW Series
TEMP.
COEFF.
VOLTAGE
%/°C
(TYP)
PROGRAMMING CONSTANTS
VOLTAGE MODES
OUTPUT POWER
CONSTANT VOLTAGE MODE*
COMBINED
REGULATION
LINE AND
VOLTAGE
DRIFT %
VMAX
MODEL
RIPPLE
(RMS)**
(TYP.)
NOISE TRANSIENT
VOLTAGE CURRENT
LOAD %
(TYP)
(P-P)
(TYP)
RESPONSE
TIME (TYP)
OHMS/V
V/V
VDC
ADC @ 50°C
DCS 8-140E
DCS 10-120E
DCS 20-60E
DCS 33-36E
DCS 40-30E
DCS 50-24E
DCS 60-20E
DCS 80-15E
DCS 100-12E
DCS 150-8E
DCS 300-4E
0-8
0-10
0-20
0-33
0-40
0-50
0-60
0-80
0-100
0-150
0-300
0-140
0-120
0-60
0-36
0-30
0-24
0-20
0-15
0-12
0-8
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
5mV
5mV
5mV
5mV
5mV
5mV
5mV
5mV
10mV
15mV
25mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
60mV
160mV
200mV
500s
500s
500s
500s
500s
500s
500s
500s
500s
500s
500s
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.02
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
0.05
625
500
250
151.5
125
100
83
62.5
50
33.3
16.67
0-10V = 0-100% V
or
o
0-5V = 0-100% V
o
0-4
485
Your dependable power partner – www.powerbox.com.au
DCS Series
1000-3000 WATTS PROGRAMMABLE DC SUPPLY
Options & Accesssories
INPUT VOLTAGE OPTIONS
J3 PROGRAM AND SENSE
M1
Factory configured for 115 VAC input (1 and 1.2 kW only)
REMOTE INTERFACE OPTIONS
Internal IEEE-488/RS 232 interface (Supports only 12-bit slaves)
Locking shafts (front panel potentiometers)
Master/slave cable configured for two or more units
Replace input connector with terminal block(3 kW only)
Isolated analog programming control
1
2
3
4
5
6
7
8
9
90-250 VAC Remote Shutdown 14 TTL Shutdown
Shutdown Return
OVP Program
15 +12 VDC
M9C
16 1 mACurrent Source (OVP)
M13
Remote/Local Status Indicator 17 OVP Indicator
M32
M33
Mode Status Indicator
Ground
18 Thermal S/DN Status
M51A
M102
M85
19 0-5V Voltage Monitor
20 Remote Voltage Select
21 1 mA Current Source (V)
22 1 mA Current Source (I)
23 Remote Current Select
24 Return
Front Panel Binding Posts (1 kW and 1.2 kW only?30A)
12-bit slave interface
0-5V Current Monitor
Voltage Control
M130
M131
M133
M135
M136
Ethernet/RS232 Interface (Supports both 12- & 16-bit slaves)
16-bit slave interface
Voltage Program Input
Output disconnect and polarity reversal relays*
Output disconnect and polarity reversal relays**
Output disconnect and polarity reversal relays***
10 Current Program Unit
11 Current Control
12 Return Sense
25 POS Output (8-100V Models Only)
105-330-26 Rack slide kit (3 kW only)
13 POS Sense (8-100V Models Only
* Requires M9C ** Includes option M130 ***Includes option M131
Technical Illustrations
1KW AND 1.2KW
3KW
487
Your dependable power partner – www.powerbox.com.au
相关型号:
©2020 ICPDF网 联系我们和版权申明