HRS-1215 [POWER-SYSTEMS]

DC-DC Converter UNIT 1.8 W REGULATED DC-DC CONVERTER; DC-DC转换器单元1.8 W¯¯调节的DC- DC转换器
HRS-1215
型号: HRS-1215
厂家: POWER SYSTEMS GMBH+CO.KG    POWER SYSTEMS GMBH+CO.KG
描述:

DC-DC Converter UNIT 1.8 W REGULATED DC-DC CONVERTER
DC-DC转换器单元1.8 W¯¯调节的DC- DC转换器

转换器 DC-DC转换器
文件: 总5页 (文件大小:225K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DC-DC Converter UNIT  
HR Series ( 1.8 W REGULATED DC-DC CONVERTER )  
FEATURES  
z 1000VDC ISOLATION  
z HIGH EFFICIENCY  
z INTERNAL FILTERING  
z LOW COST  
z NO EXTERNAL COMPONENTS  
REQUIRED  
z UP TO 1.8W REGULATED OUTPUT  
POWER  
z DUAL IN LINE PACKAGE  
z 100% BURNED IN  
z LOW NOISE  
z MTBF > 850,000 HOURS  
z
OUTPUT SPECIFICATIONS  
z
INPUT SPECIFICATIONS  
Voltage Setpoint Accuracy  
+/-2% max Input Voltage Range  
+/-10% max  
O
Temperature Coefficient  
+/-0.03%/ C Input Filter  
Capacitor Type  
Ripple  
BW)  
&
Noise (20MHz  
100mVp-p max  
Line Regulation1  
+/-0.5% max  
Load Regulation2  
+/-0.5% max  
z
GENERAL SPECIFICATIONS  
Short Circuit Protection  
Current Limit Efficiency  
50% min  
Protection  
Short Circuit Restart  
Automatic Isolation Voltage3  
1000 VDC min  
9
z
ENVIRONMENTAL SPECIFICATIONS  
Isolation Resistance  
10 ohms min  
O
O
Operating Temperature  
Storage Temperature  
Cooling  
-25 C to +71 C Switching Frequency  
25 KHz min  
80pF max  
O
O
-55 C to +125 C Isolation Capacitance  
Free-Air Convection MTBF  
Weight  
850,000 Hours  
10.1g Typ  
ALL SPECIFICATIONS TYPICAL AT NOMINAL Case Material  
Non-Conductive Plastic  
32.5mm*17mm*10.2mm  
O
LINE, FULL LOAD  
OTHERWISE NOTED.  
,
AND 25  
C
UNLESS  
Case Size  
1
High Line to Low Line.  
2
3
Load Regulation is for output load current change from 0% to 100%.  
For 60 seconds  
www.Power-Systems.de  
Page: 1 / 5  
Version: 4-Oct-02  
DC-DC Converter UNIT  
HR Series ( 1.8 W REGULATED DC-DC CONVERTER )  
z SELECTION GUIDE  
1.8W OUTPUT  
INPUT  
INPUT  
OUTPUT OUTPUT  
MODEL  
CURRENT(mA)  
EFF  
(%)  
ISOLATION  
(VDC)  
VOLTAGE VOLTAGE CURRENT  
NUMBER  
FULL  
LOAD  
NO  
(VDC)  
(VDC)  
(mA)  
LOAD  
HRS-0505  
HRS-05094  
HRS-0512  
HRS-0515  
HRS-1205  
HRS-12095  
HRS-1212  
HRS-1215  
HRS-2405  
HRS-2409  
HRS-2412  
HRS-2415  
HRS-4805  
HRS-4809  
HRS-4812  
HRS-4815  
4.5-5.5  
4.5-5.5  
5
9
360  
200  
150  
120  
360  
200  
150  
120  
360  
200  
150  
120  
360  
200  
150  
120  
680  
620  
620  
600  
267  
250  
250  
241  
129  
121  
121  
117  
66  
40  
40  
38  
38  
18  
18  
16  
16  
9
53  
58  
58  
60  
56  
60  
60  
62  
58  
62  
62  
64  
57  
59  
60  
60  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
1000  
4.5-5.5  
12  
15  
5
4.5-5.5  
10.8-13.2  
10.8-13.2  
10.8-13.2  
10.8-13.2  
21.6-26.4  
21.6-26.4  
21.6-26.4  
21.6-26.4  
43.2-52.8  
43.2-52.8  
43.2-52.8  
43.2-52.8  
9
12  
15  
5
9
9
12  
15  
5
9
8
5
9
64  
5
12  
15  
63  
5
63  
5
Note: Other input to output voltages may be available. Please contact factory.  
4FOR LAN DC-DC CONVERTER  
5FOR LAN DC-DC CONVERTER  
www.Power-Systems.de  
Page: 2 / 5  
Version: 4-Oct-02  
DC-DC Converter UNIT  
HR Series ( 1.8 W REGULATED DC-DC CONVERTER )  
z MECHANICAL DIMENSIONS &  
RECOMMENDED FOOTPRINT DETAILS  
SINGLE  
+Vin  
PIN  
1&24  
2&23  
NC  
10&15  
11&14  
12&13  
-Vout  
+Vout  
-Vin  
www.Power-Systems.de  
Page: 3 / 5  
Version: 4-Oct-02  
DC-DC Converter UNIT  
HR Series ( 1.8 W REGULATED DC-DC CONVERTER )  
z SIMPLIFIED SCHEMATIC  
z TYPICAL  
APPLICATIONS  
INPUT  
OUTPUT  
REGULATOR  
+Vin  
+Vout  
+Vin  
+Vout  
OSCILLATOR  
DRIVER  
LOAD  
DC-DC  
-Vout  
CONVERTER  
-Vin  
-Vin  
-Vout  
z TYPICAL PERFORMANCE CUREVES  
EFFICIENCY VS LOAD  
DERATING CURVE  
SAFE  
2.0  
1.6  
1.2  
0.8  
0.4  
0.0  
80.0  
60.0  
40.0  
20.0  
0.0  
OPERATING  
AREA  
-25  
0
25  
50  
70  
100  
0
20  
40  
60  
80  
100  
TA(degree C)  
% OF RATED LOAD(%)  
HR SERIES APPLICATION NOTES:  
EXTERNAL CAPACITANCE REQUIREMENTS:  
No external capacitance is required for operation of the HR series.  
To meet the reflected ripple requirements of the converter, an input impedance of less than 0.5 ohm  
from DC to 100KHz is required.  
External output capacitance is not required for operation, however it is recommended that 10uF  
tantalum and 0.1uF ceramic capacitance be selected for reduced system noise.  
Additional output capacitance may be added for increased filtering, but should not exceed 220uF.  
www.Power-Systems.de  
Page: 4 / 5  
Version: 4-Oct-02  
DC-DC Converter UNIT  
HR Series ( 1.8 W REGULATED DC-DC CONVERTER )  
Negative Outputs:  
A negative output voltage may be obtained by connecting the +OUT to circuit ground and  
connecting –OUT as the negative output.  
FOR MORE INFORMATION CALL:  
Power Systems – The Power Solution  
Ilsfeld-Auenstein ( Germany ) Dörnet 8  
Tel: + 49 / 70 62 / 67 59 – 6  
Fax: + 49 / 70 62 / 67 59 -80  
E-mail: Info@Power-Systems.de  
Home Page: www.Power-Systems.de  
www.Power-Systems.de  
Page: 5 / 5  
Version: 4-Oct-02  

相关型号:

HRS-13-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-13-R/BL

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-13-R/K

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-13-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-14-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-14-R/BL

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-14-R/K

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-14-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-15-R

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-15-R/BL

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-15-R/K

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM

HRS-15-R/Q

Space-saving Plug-in Signal Conditioners H-UNIT
MSYSTEM