Multi-Output HP6 Front End  
and RACK-HP600 Data Sheet  
HP6 and RACK-HP600 Features  
Compact 1U design  
N+1 redundancy with hot plug capability  
Up to four individually regulated outputs  
I2C interface with interrupt capability  
Hot swap with low insertion/extraction force connector  
Power factor corrected  
No minimum load required  
5 V @ 1 A standby output  
Single-wire current sharing  
Self-contained ORing Diodes  
Current limit and over-voltage protection  
Full power up to 50º C  
TUV, cTUVus & CB report  
600 watts per module  
HP6 Multi-Output AC-DC Front End  
Ac input with PFC  
RACK-HP600  
Description  
The HP6 provides up to 600 Watts total output power with one to four outputs ranging from 0.8 to 12 Volts. HP600  
RACKS offer hot-plug capability for up to 1200 Watts total at low line (2 +1) or 1800 Watts total at high line. Three  
separate multi output power supplies are internally paralleled and will automatically current share for load  
distribution. Hot-swap modules can be replaced with no system downtime.  
V1  
V2  
V3  
V4  
HP6 Front End Models  
HP6-X8X8D2D-O  
HP6-X4X8D4D-O  
HP6-X8X4D4D-O  
HP6-X8X4D2D-O  
HP6-X4X8D2D-O  
HP6-X4X4D4D-O  
Volts Amps Volts Amps Volts Amps Volts Amps  
X
X
X
X
X
X
80  
40  
80  
80  
40  
40  
X
X
X
X
X
X
80  
80  
40  
40  
80  
40  
12  
12  
12  
12  
12  
12  
20  
40  
40  
20  
20  
40  
-12  
-12  
-12  
-12  
-12  
-12  
3
3
3
3
3
3
RACK-HP600 Designations  
RACK-HP600  
X
240  
X
120  
12  
120  
-12  
9
Output Voltage X = A (2.0V); B (3.3V); C (5V); T (2.5V); V (1.8V); W (1.5V); X (1.2V); Y (1V); Z (0.8V)  
Options O = B (I2C); M (Output power good – TTL high); N (Power fail – TTL high); R (Reverse airflow)  
Please contact Power-One for additional model combinations.  
Nov 7, 2006  
Page 1 of 4  
www.power-one.com  
Multi-Output HP6 Front End  
and RACK-HP600 Data Sheet  
Input Specifications  
Signals and Controls  
LED Output Good Indicator: Front panel green LED indicates  
power supply is good; amber indicates fault.  
Input voltage range: 85 to 264 Vac, 47 to 63 Hz  
Power Factor: 0.99 at full load and nominal line  
Inrush Current: 40 A peak hot and cold start  
Input Protection: Internal 15 A line fuse  
LED AC Good Indicator: Front panel green LED indicates  
Ac input voltage is present and above minimum level.  
Output Good Signal*: TTL compatible signal, normally high.  
Goes low when power supply is out of specified range.  
Power Fail Signal*: TTL compatible signal, normally high  
(indicating Vin is present and above minimum level).  
Enable*: Normally TTL High, drive low to enable.  
*All interface signals are TTL compatible  
Output Specifications  
Output Power: 600 W maximum  
Overshoot/Undershoot: Less than 1% at turn-on or turn-  
off. Less than 3% for 50% to 100% load step.  
Start-Up Time: Less than 2 seconds  
Efficiency: 78% typical measured at full load, nominal input  
Hold-up Time: 20 ms minimum at full load and low line  
Single Wire Current Share (V1, V2 and +12V): 10% full  
load rating.  
Load Regulation: 0.5% with remote sense, 2% without  
Line Regulation: 0.1% over entire operating range  
Cross Regulation: Less than 0.5%  
Minimum Load: No minimum load required  
Overcurrent Protection: All outputs set to 115-135% of full  
rated load with automatic recovery  
Overtemperature Protection: Automatic shutdown with  
auto recovery.  
Remote Sense: Compensates for voltage drop of up to 0.5  
V to the load (V1, V2, and +12V). Shorted sense lead  
protection.  
Overvoltage Protection: All outputs set at 115%-135% of  
nominal. Reset by cycling input power.  
I2C Interface  
Event Driven Messages:  
• Notification of fan speed abnormality  
• Output voltage under specified ‘good’ range  
• Output voltage over specified ‘good’ range (software OVP)  
• Temperature abnormalities  
Sensor Device Commands:  
• Get voltage readings  
• Get temperature readings  
• Get fan speed readings  
FRU (Field Replaceable Unit) Information Storage:  
• Manufacturer’s name  
• Product name  
• Product part/model number  
• Product version/revision  
• Product serial number  
Output Noise and Ripple: PARD: 1% or 50 mV p-p,  
whichever is greater, measured at 20 Mhz bandwidth.  
Safety & Environmental  
Operating Temperature: 0 to 50°C  
Storage Temperature: -40°C to +85°C  
Operating Humidity: Maximum 95% RH non-condensing  
Operating Altitude: 10,000 feet  
Non-operating Altitude: 40,000 feet  
Temperature Coefficient: 0.02% per °C within rated load  
Safety Agency Compliance: TUV, cTUVus & CB report  
EMI: Meets EN55022, Class B  
Mechanical Specifications  
Size: 1.6” H x 5” W x 11.5” D  
Input Connector: Front panel IEC  
Output Connector: FCI power blade  
MTBF: 250,000 hours calculated at 25 °C, Bellcore  
Standard  
Warranty: Two years from date of shipment, standard  
product only.  
Harmonic Suppression: Meets EN6100-3-2  
Input Transient Protection:  
Electrostatic Discharge: EN61000-4-2, Criteria B  
Radiated, Radio-Frequency, Electromagnetic Field:  
EN61000-4-3, Criteria A  
Specifications are subject to change without prior notice.  
Electrical Fast Transients/Burst: EN61000-4-4, Criteria B  
Voltage Fluctuations and Flickers: EN61000-3-3, Criteria B  
Surge Test: EN61000-4-5, Criteria B  
Conducted Immunity: EN61000-4-6, Criteria A  
Dielectric Withstand:  
Input-to-ground: 2200 Vdc  
Input-to-output: 4300 Vdc  
Output-to-case: 25 Vdc  
Ac Leakage Current: 1.2mA maximum at 240 Vac, 50 Hz  
Nov 7, 2006  
Page 2 of 4  
www.power-one.com  
Multi-Output HP6 Front End  
and RACK-HP600 Data Sheet  
HP6 Outline Drawings and Dimensions  
HP6 Connector Pin Descriptions  
HP6 PIN Numbers and Signal Names  
HP6 J5 Connector Detail  
1 Ground  
2 Ground  
3 V2 Output  
4 V2 Output  
5 V2 Output  
6 Ground  
18 Share V2  
19 +Sense V2  
20 SDA  
21 SCL  
22 Share V3  
23 Power Fail OK  
24 5V Standby  
25 5V Standby  
26 +Sense V3  
27 Power OK  
28 Present  
7 Ground  
8 Ground  
9 V1 Output  
10 V1 Output  
11 V1 Output  
12 Dc Enable  
13 A1  
29 A0  
30 Interrupt  
14 -Sense  
31 Share V1  
32 Ground  
33 V3 Output (+12V)  
34 V3 Output (+12V)  
15 +Sense V1  
16 V4 Output (-12V)  
17 V4 Output (-12V)  
Nov 7, 2006  
Page 3 of 4  
www.power-one.com  
Multi-Output HP6 Front End  
and RACK-HP600 Data Sheet  
RACK-HP600 Outline Drawings and Dimensions  
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical  
components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written  
consent of the respective divisional president of Power-One, Inc.  
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on  
the date manufactured. Specifications are subject to change without notice.  
Nov 7, 2006  
Page 4 of 4  
www.power-one.com  

相关型号:

HP6-X4X8D4D-O

Multi-Output AC-DC Front End
POWER-ONE

HP6-X8X4D2D-O

Multi-Output AC-DC Front End
POWER-ONE

HP6-X8X4D4D-O

Multi-Output AC-DC Front End
POWER-ONE

HP600

Multi-Output HP600 AC-DC Front End Data Sheet
POWER-ONE

HP601

Optoelectronic Device,
KODENSHI

HP6800M100-3560

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 100V, 20% +Tol, 20% -Tol, 6800uF
YSTONE

HP6800M50-2550

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 50V, 20% +Tol, 20% -Tol, 6800uF
YSTONE

HP680M200-3030

Aluminum Electrolytic Capacitor, Polarized, Aluminum, 200V, 20% +Tol, 20% -Tol, 680uF
YSTONE

HP6B-SERIES

Analog IC
ETC

HP6T-SERIES

Analog IC
ETC

HP7-189S-1.27DS

Board Connector, 96 Contact(s), 3 Row(s), Female, Right Angle, Solder Terminal, Socket,
HRS

HP75

DATA SUBJECT TO CHANGE WITHOUT NOTLCE
HAMMOND