3209633 [PHOENIX]
Modular Terminal Block, 24A, 4mm2, 1 Row(s), 1 Deck(s),;型号: | 3209633 |
厂家: | PHOENIX CONTACT |
描述: | Modular Terminal Block, 24A, 4mm2, 1 Row(s), 1 Deck(s), 端子和端子排 |
文件: | 总6页 (文件大小:101K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Feed-through terminal block, nom. voltage: 500 V, nominal current: 24 A, connection method: Push-in / plug
connection, number of connections: 3, number of positions: 1, cross section:0.14 mm² - 4 mm², AWG: 26 - 12,
width: 5.2 mm, height: 35.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15
Why buy this product
The Push-in connection terminal blocks are characterized by the system features of the CLIPLINE complete system and by easy and tool-free
wiring of conductors with ferrules or solid conductors
The compact design and front connection enable wiring in a confined space
In addition to the testing facility in the double function shaft, all terminal blocks provide an additional test connection
Tested for railway applications
Key Commercial Data
Packing unit
50 STK
GTIN
GTIN
4046356333382
Technical data
General
Number of positions
Number of levels
1
1
Number of connections
Potentials
3
1
Nominal cross section
Color
2.5 mm²
gray
Insulating material
Flammability rating according to UL 94
Area of application
PA
V0
Railway industry
Machine building
Plant engineering
6 kV
Rated surge voltage
02/09/2018 Page 1 / 6
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Technical data
General
Degree of pollution
3
Overvoltage category
III
Insulating material group
I
Maximum power dissipation for nominal condition
Maximum load current
0.77 W
24 A (with 4 mm² conductor cross section)
Nominal current IN
24 A (observe derating)
Nominal voltage UN
500 V
Open side panel
Yes
Insertion/withdrawal cycles mechanical
Result of surge voltage test
Surge voltage test setpoint
Result of power-frequency withstand voltage test
Power frequency withstand voltage setpoint
Result of tight fit on support
Tight fit on carrier
100
Test passed
7.3 kV
Test passed
3.31 kV
Test passed
NS 35
Setpoint
1 N
Short circuit stability result
Test passed
Conductor cross section short circuit testing
Short-time current
2.5 mm²
0.3 kA
Conductor cross section short circuit testing
Short-time current
4 mm²
0.48 kA
Result of thermal test
Test passed
Proof of thermal characteristics (needle flame) effective duration
Oscillation, broadband noise test result
Test specification, oscillation, broadband noise
Test spectrum
30 s
Test passed
DIN EN 50155 (VDE 0115-200):2008-03
Service life test category 1, class B, body mounted
f1 = 5 Hz to f2 = 150 Hz
Test frequency
1.857 (m/s2)2/Hz
ASD level
Acceleration
0,8 g
Test duration per axis
Test directions
5 h
X-, Y- and Z-axis
Shock test result
Test passed
Test specification, shock test
Shock form
DIN EN 50155 (VDE 0115-200):2008-03
Half-sine
Acceleration
5 g
Shock duration
30 ms
Number of shocks per direction
Test directions
3
X-, Y- and Z-axis (pos. and neg.)
130 °C
Relative insulation material temperature index (Elec., UL 746 B)
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
125 °C
02/09/2018 Page 2 / 6
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Technical data
General
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
-60 °C
Test passed
V0
Oxygen index (DIN EN ISO 4589-2)
>32 %
NF F16-101, NF F10-102 Class I
2
NF F16-101, NF F10-102 Class F
2
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
passed
passed
passed
27,5 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
5.2 mm
2.2 mm
60.5 mm
35.2 mm
36.5 mm
44 mm
End cover width
Length
Height
Height NS 35/7,5
Height NS 35/15
Connection data
Connection method
Push-in / plug connection
Connection in acc. with standard
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section AWG min.
Conductor cross section AWG max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Min. AWG conductor cross section, flexible
Max. AWG conductor cross section, flexible
IEC 61984
0.14 mm²
4 mm²
26
12
0.14 mm²
2.5 mm²
26
14
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 2.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
0.14 mm²
2.5 mm²
2 conductors with same cross section, stranded, TWIN ferrules with
plastic sleeve, max.
0.5 mm²
Stripping length
8 mm ... 10 mm
A3
Internal cylindrical gage
02/09/2018 Page 3 / 6
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Technical data
Standards and Regulations
Connection in acc. with standard
CSA
IEC 61984
Flammability rating according to UL 94
V0
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
Diagram
30
25
20
15
10
5
!
= 5-pos.
= 5-pos.
= 10-pos.
= 15-pos.
!
0
0
20
40
60
80
100
Ambient temperature [°C]
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / RS / ABS / NK / BV / CSA / EAC / EAC / DNV GL / LR / cULus Recognized
Ex Approvals
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
FILE E 60425
B
mm²/AWG/kcmil
Nominal current IN
26-12
20 A
26-12
20 A
02/09/2018 Page 4 / 6
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Approvals
B
C
Nominal voltage UN
cUL Recognized
600 V
600 V
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
C
FILE E 60425
B
mm²/AWG/kcmil
26-12
20 A
26-12
20 A
Nominal current IN
Nominal voltage UN
600 V
600 V
RS
ABS
NK
http://www.rs-head.spb.ru/en/index.php
http://www.eagle.org/eagleExternalPortalWEB/
http://www.classnk.or.jp/hp/en/
11.04057.250
16-HG1591536-PDA
14ME0912
http://www.veristar.com/portal/veristarinfo/generalinfo/
approved/approvedProducts/equipmentAndMaterials
BV
25278/B0 BV
CSA
http://www.csagroup.org/services-industries/product-listing/
13631
B
C
mm²/AWG/kcmil
26-12
26-12
20 A
300 V
Nominal current IN
Nominal voltage UN
20 A
300 V
EAC
EAC
EAC-Zulassung
7500651.22.01.00246
02/09/2018 Page 5 / 6
https://www.phoenixcontact.com/pi/products/3209633
Feed-through terminal block - PT 2,5-TWIN/1P - 3209633
Approvals
DNV GL
LR
http://exchange.dnv.com/tari/
http://www.lr.org/en
TAE00000UD_01
10/20040
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
02/09/2018 Page 6 / 6