3029813 [PHOENIX]
Modular Terminal Block, 24A, 2.5mm2,;型号: | 3029813 |
厂家: | PHOENIX CONTACT |
描述: | Modular Terminal Block, 24A, 2.5mm2, 端子和端子排 |
文件: | 总4页 (文件大小:66K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/3029813
Mini feed-through terminal block - MZFKK 1,5 - 3029813
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Mini feed-through terminal block, connection method: Spring-cage connection, cross section: 0.14 mm² - 2.5
mm², AWG: 26 - 14, width: 5.2 mm, color: gray, mounting type: NS 35/7,5, NS 35/15, NS 15
Why buy this product
Each terminal point can be labeled
Space saving thanks to compact design and mounting option on a 15 mm DIN rail
Clear arrangement thanks to marking of all terminal points
Easy potential distribution thanks to standardized plug-in bridges
Key Commercial Data
Packing unit
50 STK
GTIN
GTIN
4017918187149
Technical data
General
Number of levels
2
Number of connections
Nominal cross section
4
1.5 mm²
Color
gray
Insulating material
PA
Flammability rating according to UL 94
Rated surge voltage
V0
6 kV
Degree of pollution
3
Overvoltage category
III
Insulating material group
Maximum power dissipation for nominal condition
Connection in acc. with standard
I
0.56 W (the value is multiplied when connecting multiple levels)
IEC 60947-7-1
02/09/2018 Page 1 / 4
https://www.phoenixcontact.com/pi/products/3029813
Mini feed-through terminal block - MZFKK 1,5 - 3029813
Technical data
General
Nominal current IN
17.5 A
Maximum load current
24 A (with a 2.5 mm² conductor cross section)
Nominal voltage UN
500 V
Yes
Open side panel
Relative insulation material temperature index (Elec.; UL 746 B)
130 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE
0304-21))
130 °C
Static insulating material application in cold
Behavior in fire for rail vehicles (DIN 5510-2)
Flame test method (DIN EN 60695-11-10)
-60 °C
Test passed
V0
Oxygen index (DIN EN ISO 4589-2)
>32 %
NF F16-101, NF F10-102 Class I
2
NF F16-101, NF F10-102 Class F
2
Surface flammability NFPA 130 (ASTM E 162)
Specific optical density of smoke NFPA 130 (ASTM E 662)
Smoke gas toxicity NFPA 130 (SMP 800C)
Calorimetric heat release NFPA 130 (ASTM E 1354)
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
passed
passed
passed
28 MJ/kg
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
HL 1 - HL 3
Dimensions
Width
5.2 mm
67.5 mm
42 mm
Length
Height NS 15
Height NS 35/7,5
Height NS 35/15
42.5 mm
50 mm
Connection data
Connection method
Spring-cage connection
Conductor cross section solid min.
Conductor cross section solid max.
Conductor cross section flexible min.
Conductor cross section flexible max.
Conductor cross section AWG min.
Conductor cross section AWG max.
0.14 mm²
2.5 mm²
0.14 mm²
1.5 mm²
26
14
Conductor cross section flexible, with ferrule without plastic sleeve min. 0.14 mm²
Conductor cross section flexible, with ferrule without plastic sleeve max. 1.5 mm²
Conductor cross section flexible, with ferrule with plastic sleeve min.
Conductor cross section flexible, with ferrule with plastic sleeve max.
Stripping length
0.14 mm²
1.5 mm²
9 mm
02/09/2018 Page 2 / 4
https://www.phoenixcontact.com/pi/products/3029813
Mini feed-through terminal block - MZFKK 1,5 - 3029813
Technical data
Standards and Regulations
Connection in acc. with standard
CUL
IEC 60947-7-1
Flammability rating according to UL 94
V0
Fire protection for rail vehicles (DIN EN 45545-2) R22
Fire protection for rail vehicles (DIN EN 45545-2) R23
Fire protection for rail vehicles (DIN EN 45545-2) R24
Fire protection for rail vehicles (DIN EN 45545-2) R26
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3 HL 1 - HL 3
Environmental Product Compliance
China RoHS
Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
Circuit diagram
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals
Approval details
UL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 60425
mm²/AWG/kcmil
26-14
15 A
Nominal current IN
Nominal voltage UN
600 V
02/09/2018 Page 3 / 4
https://www.phoenixcontact.com/pi/products/3029813
Mini feed-through terminal block - MZFKK 1,5 - 3029813
Approvals
cUL Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
FILE E 60425
mm²/AWG/kcmil
26-14
15 A
Nominal current IN
Nominal voltage UN
600 V
EAC
7500651.22.01.00246
cULus Recognized
http://database.ul.com/cgi-bin/XYV/template/LISEXT/1FRAME/index.htm
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
02/09/2018 Page 4 / 4
相关型号:
302993
Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools
TE
302994
Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools
TE
302994-1
Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools
TE
©2020 ICPDF网 联系我们和版权申明