2941154 [PHOENIX]

INTERFACE Relay -INTERFACE Cabling;
2941154
型号: 2941154
厂家: PHOENIX CONTACT    PHOENIX CONTACT
描述:

INTERFACE Relay -INTERFACE Cabling

文件: 总3页 (文件大小:114K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
INTERFACE Relay -  
INTERFACE Cabling  
Installation guidelines for the product groups:  
INTERFACE Relay  
INTERFACE Cabling  
Application note  
104155_en_02  
© PHOENIX CONTACT 2017-09-18  
1
General notes  
1.1  
Scope of validity of this application note  
INTERFACE Cabling – I/O wiring between the field and  
automation level  
This application note is only valid for INTERFACE Relay  
(excluding CONTACTRON) and INTERFACE Cabling  
products.  
Wiring interface – Contact individual wires with  
high-pos. connectors (VIP, UMK, etc.)  
System cabling – Plug and play control cabinet wiring  
(FLK, FLKM, etc.)  
Cables – Pre-assembled cables with D-SUB or FLK  
strip  
INTERFACE Relay – Optocouplers and relays  
RIFLINE complete series - Pluggable relays and  
optocouplers with pluggable input/interference  
suppression modules  
PLC series – 6.2/14 mm wide with plug-in relays and  
optocouplers  
PLC-V8C/... products  
PR series – Plug-in relays and optocouplers with  
plug-in input/interference suppression modules  
DEK series – Relay modules with modular terminal  
block design  
EMG series – Modular relays and optocouplers  
ST series – Relays and optocouplers that can be  
plugged into modular terminal blocks  
1.2  
Intended use  
INTERFACE Relay and INTERFACE Cabling products  
should only be used according to the instructions in the  
product-specific documentation and in this application note.  
Phoenix Contact accepts no liability if the products are used  
for anything other than their designated use.  
1.3  
Voltage classes  
The voltage classes meet the requirements of EN 61140.  
Special relay and solid-state relay modules  
Does not apply to CONTACTRON  
Make sure you always use the latest documentation.  
It can be downloaded at phoenixcontact.net/products.  
INTERFACE Relay - INTERFACE Cabling  
2
Safety notes for use in the low voltage area  
2.1  
Notes for personnel  
Phoenix Contact cannot guarantee the suitability of the  
procedures or the circuit suggestions described for the  
relevant application.  
The products are to be classified as "not short-circuit-proof"  
in case "short-circuit-proof" or "conditionally short-circuit-  
proof" are not specified in the product description. For the  
dimensioning of the overload protection devices take into  
account the connection cross-sections and the documented  
maximal continuous current (limiting continuous current).  
WARNING: INTERFACE Relay and  
INTERFACE Cabling products must only be used  
by qualified personnel (qualified electricians or  
persons instructed in electrical engineering).  
An electrically skilled person who because of their  
training, experience and instruction, and knowledge of  
relevant standards, can assess any required operations  
and recognize any possible dangers. (Definition  
according to DIN VDE 1000-10)  
An electrically instructed person is someone who has  
been instructed and, if necessary, trained by an  
electrically skilled person in their required tasks and the  
possible dangers caused by incorrect handling and  
who has also been informed of the necessary safety  
equipment, personal safety equipment and safety  
measures. (Definition according to DIN VDE 1000-10)  
2.3  
Removing or replacing components  
WARNING: Dangerous contact voltage  
If live parts become freely accessible due to the  
removal, replacement or absence of components  
(e.g., fuses, connectors, etc.), if voltage is  
present (SELV/25 V AC; 60 V DC) it should  
be assumed that dangerous contact voltage is  
present.  
2.2  
Installation and startup  
WARNING: Before removing, replacing or fitting  
components, disconnect the power to the  
application and ensure that it cannot be switched  
on again.  
WARNING: The power supply must be  
disconnected when carrying out any work  
(installation, maintenance, cleaning, etc.).  
Observe the national regulations and standards.  
WARNING: Make sure the entire application is  
reassembled before switching the power back on.  
If these instructions are not followed, there is a  
danger of damage to health or even of a  
life-threatening injury.  
WARNING: During operation, this equipment  
may have dangerous, live parts.  
They can therefore cause considerable damage  
to health or equipment, e.g., due to the  
unauthorized removal of protective covers or  
inadequate maintenance.  
Observe the notes in the product-specific  
documentation.  
Observe the notes in the product-specific  
documentation.  
2.4  
Electrostatic discharge  
All items to be protected against ESD are supplied in an  
ESD bag.  
It is prohibited for unqualified personnel to work on the  
products, on the machine or in their vicinity.  
Only qualified personnel should pack, unpack, mount, and  
remove an item while observing the ESD regulations.  
When working on the products and the system, you must  
always keep the operating instructions and other items of  
product documentation to hand and observe the information  
therein.  
NOTE: Electrostatic discharge  
The device contains components that can be  
damaged or destroyed by electrostatic discharge.  
When handling the device, observe the  
necessary safety precautions against  
electrostatic discharge (ESD), according to  
EN 61340-5-1 and  
The application notes and the circuit details presented in the  
product-specific documentation should be understood in a  
general sense and the relevant application should be tested  
to see if they apply.  
DIN IEC/TR 61340-5-1 VDE 300-5-2.  
104155_en_02  
PHOENIX CONTACT  
2 / 3  
INTERFACE Relay - INTERFACE Cabling  
2.5  
Installation  
2.7  
Overheating  
WARNING: Shock protection  
WARNING: Overheating can cause burns and  
can damage the device.  
Products with IP00 and IP20 protection  
(25 V AC/60 V DC) are designed for use in a  
closed control cabinet or control box  
During installation, observe any product-specific  
special requirements, such as derating and mounting  
positions.  
(terminal box) with IP54 protection or higher.  
Provide a fuse depending on the load.  
Protection in case of indirect contact  
If no secure separation or reinforced insulation is  
available between voltages dangerous to the touch and  
safety extra-low voltages you must handle the safety  
extra-low voltage like a voltage dangerous to the touch.  
During installation, observe any product-specific  
special requirements such as the use of insulating  
plates for certain voltage ranges, derating, mounting  
positions, the minimum bending radius of cables, and  
electrical safety, etc.  
Against adjacent modules in the support rail direction at  
least one functional insulation is complied with. If the  
application has higher requirements of the insulation  
(base or reinforced insulation), then you have to realize  
these by means of suitable measures (e.g. separator  
plates).  
Observe the notes in the product-specific  
documentation.  
2.8  
Grounding  
A distinction is made between functional earth ground (FE)  
and protective earth ground (PE). Functional earth ground is  
only used to increase interference resistance. It does not  
provide shock protection for people.  
Protective earth ground is a low-impedance current path  
that minimizes the risk to the operator in the event of an  
error. Errors include high-voltage errors and/or current  
errors between an electrical circuit and ground. Protective  
earth ground is largely used outside the SELV area.  
Observe the applicable directives and regulations  
Protective earth grounding (PE)  
inside the control cabinet.  
Protective earth grounding protects people and machines  
against hazardous voltages.  
To avoid these dangers, correct installation, taking the local  
conditions into account, is vital.  
Observe the ambient temperatures and any other  
special requirements (such as derating) specified in the  
data sheets and package slips.  
Observe the notes in the product-specific  
documentation.  
WARNING: If a product has a PE connection  
terminal block, this must be connected.  
2.6  
Device replacement  
Observe the notes in the product-specific  
documentation.  
WARNING: Do not replace devices while the  
power is connected.  
Functional earth grounding (FE)  
Before removing an item from or inserting an item in the  
application, disconnect the power to the entire  
application.  
Make sure the entire application is reassembled before  
switching the power back on.  
Function earth grounding is used to increase resistance to  
interference. Functional earth ground (FE) is only used to  
discharge interference. It does not provide shock protection  
for people.  
For additional notes, please refer to the product-  
specific data sheets and package slips.  
2.9  
Demands on the power supply  
WARNING: Dangerous contact voltage  
Only use power supply units that ensure safe  
isolation between the primary and secondary  
circuits according to EN 50178.  
PHOENIX CONTACT GmbH & Co. KG • Flachsmarktstraße 8 • 32825 Blomberg • Germany  
phoenixcontact.com  
104155_en_02  
3 / 3  

相关型号:

294120B822GO2

Mica Capacitor, Mica, 12000V, 0.0082uF
CDE

294120D802GO1

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.008uF
CDE

294120D802JO1

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.008uF
CDE

294120D802JO2

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.008uF
CDE

294120D822GO1

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.0082uF
CDE

294120D822JO1

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.0082uF
CDE

294120D822JO2

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.0082uF
CDE

294120D912GO1

Mica Capacitor, Mica, 12000V, -/+100ppm/Cel TC, 0.0091uF
CDE

2941361

Relays/Accessories,
PHOENIX

2941374

Relays/Accessories,
PHOENIX

2941439

Relays/Accessories,
PHOENIX

294150B432GO1

Mica Capacitor, Mica, 15000V, 0.0043uF
CDE