1407316 [PHOENIX]
SAC-4P-MR/10 0-28R SCO RAIL;型号: | 1407316 |
厂家: | PHOENIX CONTACT |
描述: | SAC-4P-MR/10 0-28R SCO RAIL 连接器 |
文件: | 总4页 (文件大小:107K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
https://www.phoenixcontact.com/pi/products/1407316
Sensor/actuator cable - SAC-4P-MR/10,0-28R SCO RAIL - 1407316
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
Sensor/actuator cable, 4-position, PE-X halogen-free, black, shielded, Plug angled M12 SPEEDCON, A-
coded, on free cable end, cable length: 10 m, For railway applications
Why buy this product
Easy and safe: 100% electrically tested plug-in components
Safety thanks to flame retardancy: PA 6.6 grip and radiation-cross-linked cables satisfy the most stringent requirements
Securely locked by special vibration brake
Resistant to temperature influences – tested for an extended temperature range and for resistance to temperature shocks
Reliable signal transmission – 360° shielding in environments with electromagnetic interference
Key Commercial Data
Packing unit
1 STK
GTIN
GTIN
4046356774321
Technical data
Dimensions
Length of cable
10 m
Ambient conditions
Ambient temperature (operation)
Degree of protection
-40 °C ... 85 °C (Plug / socket)
IP65
General
Further products with variable cable type and variable cable length can
be found in the accessories section
Note
Rated current at 40°C
Rated voltage
4 A
250 V AC
250 V DC
4
Number of positions
02/08/2018 Page 1 / 4
https://www.phoenixcontact.com/pi/products/1407316
Sensor/actuator cable - SAC-4P-MR/10,0-28R SCO RAIL - 1407316
Technical data
General
Insulation resistance
Coding
≥ 100 MΩ
A - standard
Standards/regulations
M12 connector IEC 61076-2-101
Shock, vibration EN 50155
Status display
No
Protective circuit/component
Overvoltage category
Degree of pollution
Insertion/withdrawal cycles
Torque
Unwired
II
3
≥ 100
0.4 Nm (M12 connector)
Material
Flammability rating according to UL 94
Contact material
V0
CuSn
Contact surface material
Contact carrier material
Material of grip body
Ni/Au
PA 6.6
PA 6.6
Material, knurls
Zinc die-cast, nickel-plated
PA 6.6: Fire protection in rail vehicles - requirement sets R22, R23, and
R24 acc. to DIN EN 45545-2 (Risk level HL1 - HL3)
Standards/regulations
Standards and Regulations
Standard designation
M12 connector
IEC 61076-2-101
Shock, vibration
EN 50155
Standards/regulations
Standard designation
Standards/regulations
Flammability rating according to UL 94
V0
Cable
Shielded black RADOX®
Cable type
Cable type (abbreviation)
Conductor cross section
AWG signal line
28R
4x 0.5 mm²
20
Conductor structure signal line
Core diameter including insulation
Wire colors
19x 0.18 mm
1.43 mm
White 1, white 2, white 3, white 4
Overall twist
4 wires, twisted
Shielding
Tinned copper braided shield
External sheath, color
External cable diameter D
Minimum bending radius, fixed installation
Minimum bending radius, flexible installation
black
5.4 mm ±0,3 mm
3 x D
4 x D
02/08/2018 Page 2 / 4
https://www.phoenixcontact.com/pi/products/1407316
Sensor/actuator cable - SAC-4P-MR/10,0-28R SCO RAIL - 1407316
Technical data
Cable
Cable weight
56 kg/km
Outer sheath, material
Material conductor insulation
Conductor material
PE-X
PE-X
Tin-plated Cu litz wires
≤ 40.1 Ω/km
Conductor resistance
Nominal voltage, cable
600 V AC (Core-ground, U0)
1000 V AC (Core-ground, U)
≤ 720 V AC (core-ground)
≤ 1200 V AC (Core-ground, Um)
≤ 900 V DC (Core-ground, V0)
≤ 1500 V DC (core-core)
3500 V AC (50 Hz, 5 min.)
8400 V DC (50 Hz, 5 min.)
BS 6853 (Category Ia, Ib, II)
GM/RT 2130 (Category Ia, Ib, II)
EN 45545 (Risk level HL1 - HL3)
DIN 5510 (Fire protection level 1, 2, 3, 4)
NF F16-101 (Category A1, A2, B)
NF F16-101 (Class C/F0)
NFPA 130
Test voltage, cable
Fire protection in rail vehicles
UNI CEI 11170 (Risk level LR1 - LR4)
EN 60332-1-2
Flame resistance
EN 50266
EN 50305, 9.1.2
NF C32-070, 2.1
NF C32-070, 2.2
UL 1685, 12 (FT4)
in accordance with ISO 6722-1 5.22 (UN ECE-R 118.01)
According to EN 50267-2-1
according to IRM 902, 72 h at 100 °C
Resistance to fuels according to IRM 903, 168 h at 70 °C
BS 6853 D.8.7
Halogen-free
Resistance to oil
Other resistance
Concentration of fumes
EN 61034-2
UL 1685, 12 (FT4)
Fume corrosiveness
Fume toxicity
EN 50267-2-2
BS 6853 B.1
EN 50305, 9.2
Ambient temperature (operation)
-50 °C ... 120 °C (cable, fixed installation)
-25 °C ... 90 °C (cable, flexible installation)
02/08/2018 Page 3 / 4
https://www.phoenixcontact.com/pi/products/1407316
Sensor/actuator cable - SAC-4P-MR/10,0-28R SCO RAIL - 1407316
Drawings
Schematic diagram
Cable cross section
4
3
1
2
Pin assignment M12 plug, 4-pos., A-coded, view plug side
Shielded black RADOX® [28R]
Dimensional drawing
Circuit diagram
Ø14,8
M12
1
2
4
3
WH 1
WH 4
WH 3
WH 2
Ø16
Plug M12 SPEEDCON, angled, shielded
Contact assignment of the M12 plug
Phoenix Contact 2018 © - all rights reserved
http://www.phoenixcontact.com
PHOENIX CONTACT GmbH & Co. KG
Flachsmarktstr. 8
32825 Blomberg
Germany
Tel. +49 5235 300
Fax +49 5235 3 41200
http://www.phoenixcontact.com
02/08/2018 Page 4 / 4
相关型号:
©2020 ICPDF网 联系我们和版权申明