Product Bulletin
VeriSafe™ Absence of Voltage Tester
The Safe Way to Verify the
Absence of Voltage.
When servicing electrical equipment, workers must
comply with safety regulations that require a voltage
verification test to validate the absence of voltage.
This process includes a number of stages that can
be complex and time-consuming when using
hand-held portable test instruments.
The patent-pending VeriSafe™ Absence of Voltage
Tester from Panduit simplifies this process by
automating the voltage verification process.
Once installed, a simple push of a button enables qualified electrical workers to verify the absence of voltage
and see an active indication when the absence of voltage is confirmed. This provides a new and innovative way
to safely, reliably, and efficiently verify the absence of voltage before accessing potentially dangerous electrical
equipment.
By automating this process, the VeriSafe™ Absence of Voltage Tester
• Reduces the risk of exposure of electrical hazards for improved worker safety
• Reduces testing procedure time and complexity to improve productivity
• Supports compliance when used as part of the lockout/tagout process
described in NFPA 70E*
The VeriSafe™ Absence of Voltage Tester minimizes risk by verifying the absence of voltage before equipment
is accessed, making it easier for qualified electrical workers to determine an electrically safe environment in a
fraction of the time compared to hand-held portable test instruments.
K e y F e a t u r e s
Improved Safety & Risk Reduction
B e n e f i t s
Determine voltage status BEFORE equipment is accessed
Prevents direct exposure to electrical hazards
Easy to use, initiate test with the push of a button
No additional tools required
Increased Productivity
Provides visual alert to abnormal power conditions
Test sequence based on the steps in NFPA 70E for verification of an electrically safe
work condition
Simplified Process for Easier Compliance
Automated test helps reduce operator errors
Fail-safe design with active indications
Safety functions meet SIL 3 per IEC 61508-1
Reliable Results
Designed for testing three-phase circuits up to 600V
Install on line or load side of electrical disconnect
Detects absence of AC and DC voltage
Flexible Applications
*The VeriSafe Absence of Voltage Tester satisfies the requirements for permanently mounted test devices described in
NFPA 70E-2018 120.5 (7) Exception 1 when it is installed in accordance with the ratings and instructions in the VeriSafe
AVT Installation Manual.
VeriSafe™ Absence of Voltage Tester
E l e c t r i c a l S a f e t y
Prior to performing de-energized work on electrical
equipment, NFPA 70E requires that workers verify
equipment is in an electrically safe state. Until proven
otherwise, equipment must be treated as energized and
necessary precautions must be observed.
One of the steps in the process of verifying that equipment
is in an electrically safe state involves a test for the absence
of voltage.
V e r i f y i n g t h e A b s e n c e o f V o l t a g e
Before and after testing, the functionality of the tester must
be verified on a known source. When using a portable tester,
this is a time-consuming process and may involve exposure
to electrical hazards.
Using the VeriSafe™ Absence of Voltage Tester reduces risk
and ensures the entire process is performed in the proper
sequence – every time, every test.
C o m p a r i s o n o f T e s t i n g M e t h o d s
Test
the
Check
Retest
the
Perform
Work
Select
Tester
for
Tester
Voltage
Tester
Possible Exposure to Electrical Hazards
Open
Panel
™
Activate the VeriSafe AVT
Test
Check
for
Retest
Verify
Verify
the
the
Installation
Installation
Tester
Voltage
Tester
Automatically Performed in Sequence
No Exposure to Electrical Hazards
2
VeriSafe™ Absence of Voltage Tester
M o r e t h a n a V o l t a g e I n d i c a t o r
Voltage indicators warn of hazardous voltage, but cannot be used to confirm if equipment is de-energized. Absence
of voltage testers are permanently-mounted test devices designed to verify that a circuit is de-energized prior to
opening an electrical enclosure containing electrical conductors and circuit parts.
Pressing the "TEST" button initiates
the voltage test, indicated by the
flashing YELLOW caution indicator.
RED indicators illuminate
when hazardous AC voltage
is present.
When voltage is not detected,
indicators are not illuminated.
This does not guarantee the
absence of voltage.
GREEN indicator illuminates
only when the absence of
voltage has been verified.
Upstream Power: ON
Upstream Power: OFF
Upstream Power: OFF
Upstream Power: OFF
Absence of Voltage Testers are Fail-Safe and Reliable
• Test each phase conductor or circuit part phase-to-phase and phase-to-ground for absence of voltage
• Built-in test circuit verifies operation on a known voltage source before and after absence of voltage test
• Verifies installation of hardwired test leads before and after absence of voltage test
• Functional safety principles ensure hardware and firmware are designed to prevent and control dangerous
failures of safety functions
• Installed device ensures tester is rated for the application and is less susceptible to damage than
portable testers
• Automated test sequence helps reduces operator errors
3
VeriSafe™ Absence of Voltage Tester
S y s t e m C o m p o n e n t s
Indicator Module
1
• 30mm knockout, mount on exterior of enclosure
• Operate and maintain without exposure to electrical hazards
• Instruction label with operating instructions
2
AVT System Cable
• Connects Isolation Module to Indicator Module
• 600V cable available in multiple lengths for easy
installation
• Replaceable with connectors on each end
Isolation Module
3
4
• Prevents hazardous voltage from reaching door
• Universal mounting (DIN rail or surface tabs)
2
• Output contacts provide ability to create alarms or
communicate with other systems
Sensor Leads
• Can be installed on line or load side of electrical disconnect
• 2 leads per phase; must be physically separated from each other
Simple Battery Replacement
• Long-life industrial battery
• Replaceable from outside the enclosure
• Interior battery compartment is fingersafe (IP20)
• No tools required
4
VeriSafe™ Absence of Voltage Tester
1
3
4
1
Instruction Label
5
VeriSafe™ Absence of Voltage Tester
D i m e n s i o n s *
S c h e m a t i c s
Three-Phase Delta: 3 Wire + PE
Indicator Module
4.67
[119]
Ø 1.913
[48.6]
1.54
[39.1]
PANEL
KNOCKOUT
0.180
[4.6]
Three-Phase WYE: 3 Wire + Neutral and PE
0.080
[2.0]
Isolation Module
3.96
3.31
[100.6]
[84.1]
DC System: 2 Wire +
1.51
[38.4]
3.46
[87.9]
3.68
[93.5]
1.57
[39.8]
1.29
[32.9]
Warning: The AVT must be installed correctly and grounded as described in the installation instructions to provide proper indication of absence
of voltage. Sensor leads, including ground, must not be mechanically connected to each other in order for the device to verify connection to
the circuit.
*Dimensions in inches [millimeters].
6
VeriSafe™ Absence of Voltage Tester
Three-Phase WYE High Resistance
Ground: 3 Wire + Neutral and PE
Three-Phase WYE: 3 Wire + PE (No Neutral)
Single-Phase: 2 Wire + PE
Single-Phase: 3 Wire + PE
Corner Grounded DELTA: 3 Wire + PE
High-Leg DELTA: 3 Wire + Neutral + PE
7
V o l t a g e V e r i f i c a t i o n S y s t e m
Ordering Information
Part Number
Part Description
VeriSafe™ Absence of Voltage Testers
VeriSafe™ Absence of Voltage Tester with 2 ft. system cable, 3 ft. sensor leads.
VeriSafe™ Absence of Voltage Tester with 2 ft. system cable, 10 ft. sensor leads.
VeriSafe™ Absence of Voltage Tester with 8 ft. system cable, 10 ft. sensor leads.
VS-AVT-C02-L03
VS-AVT-C02-L10
VS-AVT-C08-L10
Accessories
VS-AVT-CABLE-02
VS-AVT-CABLE-08
VeriSafe™ Replacement Cable, 2 ft.
VeriSafe™ Replacement Cable, 8 ft.
Sensor Lead Connection Kits
VS-CKBB8-4
VS-CKBB6-2
VS-CKBB2-00
VeriSafe Connection Kit for Tapping 8 to 4 AWG conductors.
VeriSafe Connection Kit for Tapping 6 to 2 AWG conductors.
VeriSafe Connection Kit for Tapping 2 to 2/0 AWG conductors.
Equipment Retrofit Kits
VS-AVT-RKBB2
VS-AVT-RKBB3
VS-AVT-RKBB4
Complete kit to retrofit equipment with VeriSafe Absence of Voltage Tester. Includes AVT device with 10ft. sensor leads, 2ft. and 8ft. system
cable, Connection Kit 8-4AWG power connectors, (12) cable ties, (6) cable ties mounts, (1) wire markers.
Complete kit to retrofit equipment with VeriSafe Absence of Voltage Tester. Includes AVT device with 10ft. sensor leads, 2ft. and 8ft. system
cable, Connection Kit 6-2AWG power connectors, (12) cable ties, (6) cable ties mounts, (1) wire markers.
Complete kit to retrofit equipment with VeriSafe Absence of Voltage Tester. Includes AVT device with 10ft. sensor leads, 2ft. and 8ft. system
cable, Connection Kit 2-2/0AWG power connectors, (12) cable ties, (6) cable ties mounts, (1) wire markers.
Technical Specifications
Applications
Electrical System
For use in 1 and 3-phase AC systems
Voltage Detection Range
Absence of Voltage Threshold
Overvoltage Category
Degree of Protection*
Up to 600V AC (50/60Hz), 600V DC; Rated tolerance +10%
3 V
III (600 V)
Indicator Module: For Flat Surface Mounting in a TYPE (UL, NEMA and CSA) 1, 12, 4, 4X, or IP66 Enclosure
Isolation Module: Open Type, IP20
Environment
Operating Temperature
Storage Temperature
Humidity
0°C to + 60°C (32°F to 140°F)
-45°C to + 85°C (-49°F to +185°F)
5 to 90% non-condensing; Rated 80% at 40°C, decreasing linearly to 50% at 60°C
Pollution Degree
Altitude
3
Up to 2000 meters (1.24 miles)
Battery
Type
Industrial 3.6V Lithium AA, see table in Maintenance section of installation guide for compatible batteries.
Standards
UL 1436
Standard for outlet circuit testers and similar indicating devices
CAN/CSA-C22.2 No. 160
IEC / UL / CSA C22.2 No. 61010-1
IEC / UL / CSA C22.2 No. 61010-2-030
Voltage and Polarity Testers
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 1: General Requirements
Safety requirements for electrical equipment for measurement, control, and laboratory use – Part 2-030: Particular
requirements for testing and measuring circuits
UL 508 & CSA-C22.2 No. 14
Industrial control equipment
IEC 61508-1, -2, and -3 {SIL 3 Rating}
Safety of Electrical/Electronic/programmable Electronic safety-related security systems –
Part 1 General Requirements
Part 2 Requirements for Electrical / Electronic / Programmable safety related systems
Part 3 Software Requirements
FCC - CFR 47 Part 15 Subpart B
IEC 61326-1, -3-1, -3-1: corr 1
EN 61326-1, -3-1
Radio frequency devices
Electrical equipment for measurement, control and laboratory use-EMC requirements - Part 1
Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions
(functional safety) - General industrial applications including corrigendum 1
EN 55011, CISPR 11
Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC / EN61000-3-2
IEC / EN61000-3-3
Electromagnetic compatibility (EMC) - Part 3-2: Limits — Limits for harmonic current emissions (equipment input current ≤ 16 A
per phase)
EN 61000-6-2
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
AS/NZS CISPR 11
Australian / New Zealand Standard - Industrial, scientific and medical equipment—Radio-frequency disturbance characteristics—
Limits and methods of measurement
CAN - ICES-001
CE
Industrial, Scientific and Medical (ISM) radio frequency generators.
Conformity Marking for European Economic Area
Restriction of hazardous substances
RoHS
*Degree of protection specified is related to the Indicator Module only. To meet the TYPE (UL, NEMA and CSA) 1, 12, 4 or 4X requirements, mount on a flat surface of an enclosure meeting the
appropriate UL TYPE or NEMA rating. Verify that the seal and o-rings are clean to ensure proper sealing.
相关型号:
VS-AVT-CABLE-08
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-AVT-RKBB2
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-AVT-RKBB3
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-AVT-RKBB4
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-CKBB2-00
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-CKBB6-2
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
VS-CKBB8-4
VeriSafe⢠Absence of Voltage Tester The Safe Way to Verify the Absence of Voltage.
PANDUIT
©2020 ICPDF网 联系我们和版权申明