TXD2-L-9V-1 [PANASONIC]
Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;型号: | TXD2-L-9V-1 |
厂家: | PANASONIC |
描述: | Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总12页 (文件大小:228K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Partly Order Discontinued as of August 31, 2011
TESTING
High breakdown voltage type
is available (1.5 kV between
open contacts)
TX-D RELAYS
2. Approved to the supplementary
insulation class in the EN standards
(EN60950).
The insulation distance between the
contact and coil meet the
7. Outstanding vibration and shock
resistance.
Functional shock resistance: 750 m/s2
Destructive shock resistance:
1,000 m/s2
w
Ne
supplementary insulation class of the
EN60950 standards as required for
equipment connected to the telephone
lines in Europe.
Satisfies the following conditions:
• Clearances: 2.0 mm .079 inch or
more
Functional vibration resistance:
10 to 55 Hz (at double amplitude of
3.3 mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of
5 mm .197 inch)
• Creepage distance: 2.5 mm .098 inch
or more
8. Sealed construction allows
automatic washing.
3. 3,000 V breakdown voltage between
contact and coil. (Surge breakdown
voltage 6,000 V type)
The body block construction of the coil
that is sealed formation offers a high
breakdown voltage of 3,000 V between
contact and coil.
9. A range of surface-mount types is
also available.
SA: Low-profile surface-mount
terminal type
SL: High connection reliability surface-
mount terminal type
SS: Space saving surface-mount
terminal type
Compliance with RoHS Directive
4. Nominal operating power:
High sensitivity of 200mW
By using the highly efficient polar
magnetic circuit “seesaw balance
mechanism”, a nominal operating
power of 200 mW has been achieved.
10. M.B.B. type available (Surge
breakdown voltage 2,500 V type
only)
TYPICAL APPLICATIONS
5. High contact capacity: 2 A 30 V DC
1. Facsimile
FEATURES
6. High contact reliability achieved
with gold-clad crossbar twin
contacts and the use of gas
expelling materials during
formation.
*We also offer a range of products with
AgPd contacts suitable for use in low
level load analog circuits (Max. 10V
DC 10 mA).
2. Modem
1. Lineup now includes high
breakdown voltage type that
achieves breakdown voltage
between open contacts of 1,500 V
AC.
3. Communications (xDSL)
4. Medical equipment
5. Automotive equipment
6. Security
Surge breakdown voltage between
open contacts:
1,500 V 10 × 160 µsec. (FCC part 68)
Surge breakdown voltage between
contact and coil:
6,000 V 1.2 × 50 µsec. (EN60950)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
ORDERING INFORMATION
TXD 2
Contact arrangement
2: 2 Form C
Surface-mount availability
Nil: Standard PC board terminal or self-clinching terminal
SA: SA type
SL: SL type
SS: SS type
Operating function
Nil: Single side stable
L: 1 coil latching
Type of operation
Nil: Standard type
2M: M.B.B. type (Surge breakdown voltage 2,500 V and Single side stable type only)
Terminal shape
Nil: Standard PC board terminal or surface-mount terminal
H: Self-clinching terminal
Nominal coil voltage (DC)
1.5, 3, 4.5, 5, 6, 9, 12, 24V
Contact material/Surge breakdown voltage (between contact and coil)/Breakdown (between open contacts)
Nil: Standard contact (Ag+Au clad), 2,500 V/1,000 V
1: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 2,500 V/1,000 V
3: Standard contact (Ag+Au clad), 6,000 V/1,500 V
4: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 6,000 V/1,500 V
6: Standard contact (Ag+Au clad ), 6,000 V/1,000 V
7: AgPd contact (low level load); AgPd+Au clad (stationary), AgPd (movable), 6,000 V/1,000 V
Packing style
Nil: Tube packing
X: Tape and reel (picked from 1/3/4/5-pin side)
Z: Tape and reel packing (Picked from the 8/9/10/12-pin side)
Note: In case of 5 V transistor drive circuit, it is recommended to use 4.5 V type relay.
TYPES
1. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2-1.5V
TXD2-3V
TXD2-L-1.5V
TXD2-L-3V
TXD2-L-4.5V
TXD2-L-5V
TXD2-L-6V
TXD2-L-9V
TXD2-L-12V
TXD2-L-24V
4.5V DC
5V DC
TXD2-4.5V
TXD2-5V
2 Form C
6V DC
TXD2-6V
9V DC
TXD2-9V
12V DC
24V DC
TXD2-12V
TXD2-24V
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
2) Self-clinching terminal
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2-H-1.5V
TXD2-H-3V
TXD2-H-4.5V
TXD2-H-5V
TXD2-H-6V
TXD2-H-9V
TXD2-H-12V
TXD2-H-24V
TXD2-L-H-1.5V
TXD2-L-H-3V
TXD2-L-H-4.5V
TXD2-L-H-5V
TXD2-L-H-6V
TXD2-L-H-9V
TXD2-L-H-12V
TXD2-L-H-24V
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
3) Surface-mount terminal
(1) Tube packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2Sꢀ-1.5V
TXD2Sꢀ-3V
TXD2Sꢀ-4.5V
TXD2Sꢀ-5V
TXD2Sꢀ-6V
TXD2Sꢀ-9V
TXD2Sꢀ-12V
TXD2Sꢀ-24V
TXD2Sꢀ-L-1.5V
TXD2Sꢀ-L-3V
TXD2Sꢀ-L-4.5V
TXD2Sꢀ-L-5V
TXD2Sꢀ-L-6V
TXD2Sꢀ-L-9V
TXD2Sꢀ-L-12V
TXD2Sꢀ-L-24V
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-1” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2Sꢀ-1.5V-Z
TXD2Sꢀ-3V-Z
TXD2Sꢀ-4.5V-Z
TXD2Sꢀ-5V-Z
TXD2Sꢀ-6V-Z
TXD2Sꢀ-9V-Z
TXD2Sꢀ-12V-Z
TXD2Sꢀ-24V-Z
TXD2Sꢀ-L-1.5V-Z
TXD2Sꢀ-L-3V-Z
TXD2Sꢀ-L-4.5V-Z
TXD2Sꢀ-L-5V-Z
TXD2Sꢀ-L-6V-Z
TXD2Sꢀ-L-9V-Z
TXD2Sꢀ-L-12V-Z
TXD2Sꢀ-L-24V-Z
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-1” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-1-Z)
2. M.B.B type/Surge breakdown voltage (between contact and coil) 2,500 V/ Breakdown voltage (between open contacts)
1,000 V
1) Standard PC board terminal
Single side stable
Contact arrangement
Nominal coil voltage
Part No.
1.5V DC
3V DC
TXD2-2M-1.5V
TXD2-2M-3V
TXD2-2M-4.5V
TXD2-2M-5V
TXD2-2M-6V
TXD2-2M-9V
TXD2-2M-12V
TXD2-2M-24V
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
2) Self-clinching terminal
Single side stable
Part No.
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
TXD2-2M-H-1.5V
TXD2-2M-H-3V
TXD2-2M-H-4.5V
TXD2-2M-H-5V
TXD2-2M-H-6V
TXD2-2M-H-9V
TXD2-2M-H-12V
TXD2-2M-H-24V
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
3) Surface-mount terminal
(1) Tube packing
Single side stable
Part No.
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
TXD2Sꢀ-2M-1.5V
TXD2Sꢀ-2M-3V
TXD2Sꢀ-2M-4.5V
TXD2Sꢀ-2M-5V
TXD2Sꢀ-2M-6V
TXD2Sꢀ-2M-9V
TXD2Sꢀ-2M-12V
TXD2Sꢀ-2M-24V
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
(2) Tape and reel packing
Single side stable
Part No.
Contact arrangement
Nominal coil voltage
1.5V DC
3V DC
TXD2Sꢀ-2M-1.5V-Z
TXD2Sꢀ-2M-3V-Z
TXD2Sꢀ-2M-4.5V-Z
TXD2Sꢀ-2M-5V-Z
TXD2Sꢀ-2M-6V-Z
TXD2Sꢀ-2M-9V-Z
TXD2Sꢀ-2M-12V-Z
TXD2Sꢀ-2M-24V-Z
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Types designed to withstand strong vibration caused, for example, by the use of terminal cutters, can also be ordered.
However, please contact us if you need parts for use in low level load. (Ex. TXD2SA-2M-1.5V-1-Z)
2. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
3. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,000 V
1) Standard PC board terminal
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2-1.5V-6
TXD2-3V-6
TXD2-4.5V-6
TXD2-5V-6
TXD2-6V-6
TXD2-9V-6
TXD2-12V-6
TXD2-24V-6
TXD2-L-1.5V-6
TXD2-L-3V-6
TXD2-L-4.5V-6
TXD2-L-5V-6
TXD2-L-6V-6
TXD2-L-9V-6
TXD2-L-12V-6
TXD2-L-24V-6
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
2) Self-clinching terminal
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2-H-1.5V-6
TXD2-H-3V-6
TXD2-H-4.5V-6
TXD2-H-5V-6
TXD2-H-6V-6
TXD2-H-9V-6
TXD2-H-12V-6
TXD2-H-24V-6
TXD2-L-H-1.5V-6
TXD2-L-H-3V-6
TXD2-L-H-4.5V-6
TXD2-L-H-5V-6
TXD2-L-H-6V-6
TXD2-L-H-9V-6
TXD2-L-H-12V-6
TXD2-L-H-24V-6
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
3) Surface-mount terminal
(1) Tube packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2Sꢀ-1.5V-6
TXD2Sꢀ-3V-6
TXD2Sꢀ-4.5V-6
TXD2Sꢀ-5V-6
TXD2Sꢀ-6V-6
TXD2Sꢀ-9V-6
TXD2Sꢀ-12V-6
TXD2Sꢀ-24V-6
TXD2Sꢀ-L-1.5V-6
TXD2Sꢀ-L-3V-6
TXD2Sꢀ-L-4.5V-6
TXD2Sꢀ-L-5V-6
TXD2Sꢀ-L-6V-6
TXD2Sꢀ-L-9V-6
TXD2Sꢀ-L-12V-6
TXD2Sꢀ-L-24V-6
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 1,000 pcs.
Note: Please add “-7” to the end of the part number for AgPd contacts (low level load).
(2) Tape and reel packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2Sꢀ-1.5V-6-Z
TXD2Sꢀ-3V-6-Z
TXD2Sꢀ-4.5V-6-Z
TXD2Sꢀ-5V-6-Z
TXD2Sꢀ-6V-6-Z
TXD2Sꢀ-9V-6-Z
TXD2Sꢀ-12V-6-Z
TXD2Sꢀ-24V-6-Z
TXD2Sꢀ-L-1.5V-6-Z
TXD2Sꢀ-L-3V-6-Z
TXD2Sꢀ-L-4.5V-6-Z
TXD2Sꢀ-L-5V-6-Z
TXD2Sꢀ-L-6V-6-Z
TXD2Sꢀ-L-9V-6-Z
TXD2Sꢀ-L-12V-6-Z
TXD2Sꢀ-L-24V-6-Z
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-7” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-7-Z)
4. Standard (B.B.M.) type/Surge breakdown voltage (between contact and coil) 6,000 V/ Breakdown voltage (between open
contacts) 1,500 V (High breakdown voltage type)
1) Standard PC board terminal
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2-1.5V-3
TXD2-3V-3
TXD2-4.5V-3
TXD2-5V-3
TXD2-6V-3
TXD2-9V-3
TXD2-12V-3
TXD2-24V-3
TXD2-L-1.5V-3
TXD2-L-3V-3
TXD2-L-4.5V-3
TXD2-L-5V-3
TXD2-L-6V-3
TXD2-L-9V-3
TXD2-L-12V-3
TXD2-L-24V-3
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
2) Surface-mount terminal
(1) Tube packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2Sꢀ-1.5V-3
TXD2Sꢀ-3V-3
TXD2Sꢀ-4.5V-3
TXD2Sꢀ-5V-3
TXD2Sꢀ-6V-3
TXD2Sꢀ-9V-3
TXD2Sꢀ-12V-3
TXD2Sꢀ-24V-3
TXD2Sꢀ-L-1.5V-3
TXD2Sꢀ-L-3V-3
TXD2Sꢀ-L-4.5V-3
TXD2Sꢀ-L-5V-3
TXD2Sꢀ-L-6V-3
TXD2Sꢀ-L-9V-3
TXD2Sꢀ-L-12V-3
TXD2Sꢀ-L-24V-3
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
ꢀ: For each surface-mount terminal identification, input the following letter. SA type: A, SL type: L, SS type: S
Standard packing: Tube: 40 pcs.; Case: 800 pcs.
Note: Please add “-4” to the end of the part number for AgPd contacts (low level load).
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
(2) Tape and reel packing
Single side stable
Part No.
1 coil latching
Part No.
Contact
arrangement
Nominal coil
voltage
1.5V DC
3V DC
TXD2SA-1.5V-3-Z
TXD2SA-3V-3-Z
TXD2SA-4.5V-3-Z
TXD2SA-5V-3-Z
TXD2SA-6V-3-Z
TXD2SA-9V-3-Z
TXD2SA-12V-3-Z
TXD2SA-24V-3-Z
TXD2SA-L-1.5V-3-Z
TXD2SA-L-3V-3-Z
TXD2SA-L-4.5V-3-Z
TXD2SA-L-5V-3-Z
TXD2SA-L-6V-3-Z
TXD2SA-L-9V-3-Z
TXD2SA-L-12V-3-Z
TXD2SA-L-24V-3-Z
4.5V DC
5V DC
2 Form C
6V DC
9V DC
12V DC
24V DC
*Only for SA type.
Standard packing: Tape and reel: 500 pcs.; Case: 1,000 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/3/4/5-pin side) is also available.
2. Please add “-4” to the part number for AgPd contacts (low level load). (Ex. TXD2SA-1.5V-4-Z)
RATING
1. Coil data
[Standard (B.B.M.) type]
1) Single side stable
Nominal operating current
[ 10%] (at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating power
Surge
Surge
Surge
Pick-up
voltage
Drop-out
voltage
Max. applied
voltage
(at 20°C 68°F)
Nominal coil
voltage
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
(at 20°C 68°F) (at 20°C 68°F)
2,500V/6,000 V
2,500V/6,000 V
2,500V/6,000 V
1.5V DC
3V DC
132.7mA
66.7mA
44.4mA
40.0mA
33.3mA
22.2mA
16.7mA
9.6mA
187.5mA
93.5mA
62.5mA
56.2mA
46.5mA
31.1mA
23.3mA
12.9mA
11Ω
45Ω
8Ω
32Ω
72Ω
4.5V DC
5V DC
101Ω
125Ω
180Ω
405Ω
720Ω
2,504Ω
75%V or less 10%V or more
120%V of
nominal
voltage
89Ω
200mW
230mW
280mW
310mW
of nominal
voltage*
(Initial)
of nominal
voltage*
(Initial)
6V DC
129Ω
289Ω
514Ω
1,858Ω
9V DC
12V DC
24V DC
2) 1 coil latching
Nominal operating current
[ 10%] (at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating power
Surge
Surge
Surge
Max. applied
voltage
(at 20°C 68°F)
Nominal coil
voltage
Set voltage
(at 20°C 68°F) (at 20°C 68°F)
Reset voltage
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
Surge
breakdown
voltage:
breakdown
voltage:
6,000 V (High
breakdown
voltage)
2,500V/6,000 V
2,500V/6,000 V
2,500V/6,000 V
1.5V DC
3V DC
100.0mA
50.0mA
33.3mA
30.0mA
25.0mA
16.7mA
12.5mA
7.1mA
153.1mA
76.9mA
51.1mA
46.3mA
38.5mA
25.6mA
19.2mA
10.4mA
15Ω
60Ω
10Ω
39Ω
88Ω
109Ω
156Ω
352Ω
626Ω
2,304Ω
4.5V DC
5V DC
135Ω
166Ω
240Ω
540Ω
960Ω
3,388Ω
75%V or less 75%V or less
120%V of
nominal
voltage
150mW
170mW
230mW
250mW
of nominal
voltage*
(Initial)
of nominal
voltage*
(Initial)
6V DC
9V DC
12V DC
24V DC
[M.B.B. type]
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal coil
voltage
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
1.5V DC
3V DC
166.7mA
83.3mA
55.6mA
50.0mA
41.7mA
27.8mA
20.8mA
11.3mA
9Ω
36Ω
81Ω
100Ω
144Ω
324Ω
576Ω
2,133Ω
4.5V DC
5V DC
75%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
250mW
270mW
120%V of
nominal voltage
6V DC
9V DC
12V DC
24V DC
*Pulse drive (JIS C 5442-1986)
*Only for surge breakdown voltage of 2,500 V.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
2. Specifications
TX-D
Characteristics
Item
Specifications
Arrangement
2 Form C
2 Form D (M.B.B.type)*1
Contact resistance (Initial)
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Standard contact: Ag+Au clad,
AgPd contact (low level load): AgPd+Au clad (stationary), AgPd (movable)
Contact
Contact material
Standard contact: 2 A 30 V DC,
1 A 30 V DC (resistive load)
Nominal switching capacity
Max. switching power
AgPd contact: 1 A 30 V DC (resistive load)
Standard contact: 60 W (DC),
30 W (DC) (resistive load)
AgPd contact: 30 W (DC) (resistive load)
Max. switching voltage
220 V DC
110 V DC
1 A
Max. switching current
Standard contact: 2 A, AgPd contact: 1 A
Min. switching capacity (Reference value)*2
10µA10mV DC
Surge breakdown voltage
2,500 V and 6,000 V types:
200mW (1.5 to 12 V DC), 230mW (24 V DC)
Surge breakdown voltage
Rating
Single side stable
250mW (1.5 to 12 V DC), 270mW (24 V DC)
6,000 V (High breakdown voltage) type:
280mW (1.5 to 12 V DC), 310mW (24 V DC)
Nominaloperating
power
Surge breakdown voltage
2,500 V and 6,000 V types:
150mW (1.5 to 12 V DC), 170mW (24 V DC)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
230mW (1.5 to 12 V DC), 250mW (24 V DC)
1 coil latching
Insulation resistance (Initial)
Between open contacts
—
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Initial breakdown voltage” section.
Surge breakdown voltage
2,500 V and 6,000 V types:
1,000 Vrms for 1min. (Detection current: 10mA)
500 Vrms for 1min. (Detection current: 10mA)
Surge breakdown voltage
6,000 V (High breakdown voltage) type:
1,500 Vrms for 1min. (Detection current: 10mA)
Breakdown
voltage (Initial)
Surge breakdown voltage 2,500 V type:
2,000 Vrms for 1min. (Detection current: 10mA)
Between contact and coil
Surge breakdown voltage 6,000 V and
6,000 V (High breakdown voltage) types:
3,000 Vrms for 1min. (Detection current: 10mA)
2,000 Vrms for 1min. (Detection current: 10mA)
Electrical
characteristics
Between contact sets
Between open contacts
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160µs) (FCC Part 68)
—
Surge breakdown voltage 2,500 V type:
2,500 V, 2 × 10µs (Telcordia)
Surge breakdown voltage 6,000 V and 6,000 V
(High breakdown voltage) types:
6,000 V, 1.2 × 50µs
Surge breakdown
Between contacts and
voltage (Initial)
2,500 V, 2 × 10µs (Telcordia)
coil*1
Max. 50°C 122°F
(By resistive method, nominal coil voltage applied to the coil;
contact carrying current: 2A [1A: M.B.B.].)
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2
Min. 500 m/s2
Functional
(Half-wave pulse of sine wave: 6 ms;
detection time: 10µs.)
(Half-wave pulse of sine wave: 11 ms;
detection time: 10µs.)
Shock
resistance
Mechanical
characteristics
Destructive
Functional
Destructive
Min. 1,000 m/s2 {100G} (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10µs.)
Vibration
resistance
10 to 55 Hz at double amplitude of 5 mm
Mechanical
Electrical
Min. 108 (at 180 cpm)
Min. 105 (2 A 30 V DC resistive),
Min. 5×105 (1 A 30 V DC resistive) (at 20 cpm)
Min. 107 (at 180 cpm)
Expected life
Min. 105 (1 A 30 V DC resistive) (at 20 cpm)
Conditions for operation, transport and
storage*3
Ambient temperature: –40°C to +85°C –40°F to +185°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Unit weight
Max. operating speed (at rated load)
20 cpm
Approx. 2 g .071 oz
Notes: *1 M.B.B. type models are only available in 2,500 V surge breakdown voltage type.
*2 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load. (AgPd contact type is available for low level load switching [10V DC, 10mA max. level])
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.Refer to [6] AMBIENT ENVIRONMENT
in GENERAL APPLICATION GUIDELINES.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
REFERENCE DATA
1. Maximum switching capacity
2. Life curve
3. Mechanical life
Tested sample: TXD2-5V, 10 pcs.
Operating speed: 180 cpm
100
90
3.0
2.0
100
50
Pick-up voltage
Drop-out voltage
80
70
60
50
40
30
20
10
0
Max.
Min.
DC resistive load
1.0
30
20
30V DC
0.5
0.4
resistive load
Max.
Min.
0.3
10
0
0.2
0
10
100
1000
10000
0
20 30 50
100
200 300
1.0
2.0
No. of operations, ×104
Contact voltage, V
Switching current, A
4. Electrical life (2 A 30 V DC resistive load)
5-(1). Coil temperature rise
Tested sample: TXD2-5V, 6 pcs.
Operating speed: 20 cpm
Tested sample: TXD2-5V, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 25°C 77°F, 70°C 158°F
Change of pick-up and drop-out voltage
Change of contact resistance
100
90
100
90
80
70
60
50
40
30
20
10
0
70
+25°C +77°F
+70°C +158°F
60
50
40
30
20
10
0
Pick-up voltage
Drop-out voltage
80
70
60
50
40
30
20
10
0
Max.
Min.
Max.
Min.
2A
2A
Max.
Min.
0A
0A
0
2
4
6
8
10
0
2
4
6
8
10
100
110
120
No. of operations, ×104
No. of operations, ×104
Coil applied voltage, %V
5-(2). Coil temperature rise
Tested sample: TXD2-24V, 6 pcs.
Measured portion: Inside the coil
6-(1). Operate/release time characteristics
(with diode)
Tested sample: TXD2-5V, 10 pcs.
6-(2). Operate/release time characteristics
(without diode)
Tested sample: TXD2-5V, 10 pcs.
Ambient temperature: 25°C 77°F, 70°C 158°F
5
5
70
+25°C +77°F
+70°C +158°F
Operate time
Release time
Operate time
Release time
60
50
40
30
20
10
0
4
4
Max.
Max.
Min.
3
Min.
3
2A
2A
Max.
2
2
0A
0A
Min.
Max.
Min.
1
1
0
0
100
110
120
70
80
90
100 110 120
70
80
90
100 110 120
Coil applied voltage, %V
Coil applied voltage, %V
Coil applied voltage, %V
7. Ambient temperature characteristics
Tested sample: TXD2-5V, 5 pcs.
8. High-frequency characteristics
(Isolation)
9. High-frequency characteristics
(Insertion loss)
Tested sample: TXD2-12V, 2 pcs.
Tested sample: TXD2-12V, 2 pcs.
40
x
20
100
50
Drop-out voltage
x
1.0
0.8
0.6
0.4
0.2
Pick-up voltage
–40 –20
0
20 40 60 80
Ambient temperature, °C
–20
–40
0
10
100
1,000
0
10
100
1,000
Frequency, MHz
Frequency, MHz
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
10. Malfunctional shock (single side stable)
Tested sample: TXD2-5V, 6 pcs
11-(1). Influence of adjacent mounting
Tested sample: TXD2-12V, 6 pcs.
11-(2). Influence of adjacent mounting
Tested sample: TXD2-12V, 6 pcs.
Deenergized
X
Z
X'
ON
ON
Y
condition
Z'
5
5
ON ON
Y
2
Energized condition
1000m/s
Pick-up voltage
Y'
0
0
X
Z
Pick-up voltage
2
2
1000m/s
1000m/s
–5
–5
5
ON
ON
OFF
OFF OFF
5
2
2
1000m/s
Z'
1000m/s
X'
Drop-out voltage
0
0
Drop-out voltage
2
OFF
1000m/s
Y'
–5
OFF
–5
OFF
0
2
4
6
8
10
0
2
4
6
8
10
.079.157.236.315.394
Inter-relay distance , mm inch
.079.157.236.315.394
Inter-relay distance , mm inch
12.Actual load test (35 mA 48V DC wire spring
relay load)
Tested sample: TXD2-5V, 6 pcs.
Change of pick-up and drop-out voltage
Change of contact resistance
100
90
100
90
80
70
60
50
40
30
20
10
0
80
Circuit
Pick-up voltage
Max.
Min.
70
60
50
458 Ω
+
0.08
µF
0.08
µF
4
3
48 V DC
TXD
Drop-out voltage
40
Max.
Min.
30
20
10
0
–
Max.
Min.
458 Ω
Wire spring relay
0
10
20
30
40
50
0
10
20
30
40
50
No. of operation, ×104
No. of operation, ×104
13-(1). Distribution of M.B.B. time
Tested sample: TXD2-2M-5V, 50 pcs.
Terminal No. 3-4-5: ON
Terminal No. 3-4-5: OFF
60
60
x:
300.5 µs
x:
298.8 µs
σn-1: 55.3 µs
Min.: 165 µs
Max.: 415 µs
σn-1: 51.8 µs
Min.: 205 µs
Max.: 432 µs
50
40
30
20
50
40
30
20
10
0
22
16
13
12
12
10
8
7
6
2
1
1
0
100 150 200 250 300 350 400 µs min.
150 200 250 300 350 400 450 µs max.
100 150 200 250 300 350 400 µs min.
150 200 250 300 350 400 450 µs max.
13-(2). Distribution of M.B.B. time
Tested sample: TXD2-2M-5V, 50 pcs.
Terminal No. 8-9-10: ON
14. Surge breakdown voltage test
Tested sample: TXD2-3V-6, 30 pcs.
Terminal No. 8-9-10: OFF
14
12
10
8
60
60
50
40
30
20
10
0
x:
293.4 µs
x:
281.4 µs
σn-1: 60.4 µs
Min.: 155 µs
Max.: 445 µs
σn-1: 58.3 µs
Min.: 120 µs
Max.: 421 µs
50
40
30
20
10
0
6
19
18
15
4
10
10
2
0
6
5
4
4
4
3
1
1
100 150 200 250 300 350 400 µs min.
150 200 250 300 350 400 450 µs max.
100 150 200 250 300 350 400 µs min.
150 200 250 300 350 400 450 µs max.
7000 7200 7400 7600 7800 8000 8200 8400 8600
Surge breakdown voltage, V
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
The CAD data of the products with a CAD Data mark can be downloaded from: http://panasonic-electric-works.net/ac
DIMENSIONS (mm inch)
1. Surge breakdown voltage 2,500 V and 6,000 V types
1) Standard PC board terminal and self-clinching terminal
External dimensions
Standard PC board terminal
PC board pattern
(Bottom view)
Schematic (Bottom view)
CAD Data
Single side stable
1 coil latching
1
3
4
5
1
3
4
5
8
15.00
.591
7.40
.291
10.16
.400
2.54
+
−
+
.100
0.65
8.20
.026
.323
5.08
.200
−
12
10
9
8
12
10
9
0.50
.020
0.25
.010
Direction indication
Direction indication
8-1.0 dia.
8-.039 dia.
5.08
.200
1.15 5.08
.045 .200
2.54
.100
3.50
.138
2,500 V type
(Deenergized condition)
(Reset condition)
Tolerance: 0.1 .004
Self clinching terminal
15.00
.591
7.40
.291
0.65
8.20
.026
.323
0.50
.020
0.25
.010
2.54
.100
5.08
.200
1.15 5.08
.045 .200
3.50
.138
6,000 V type
General tolerance: 0.3 .012
2) Surface-mount terminal
CAD Data
External dimensions (General tolerance: 0.3 .012)
Single side stable and 1 coil latching
Suggested mounting pad (Top view) (Tolerance: 0.1 .004)
Single side stable and 1 coil latching
Type
15
.591
7.4
5.08 2.54
.100
.291
.200
1
.039
3.16
.124
8.2
.323
8.4
.331
0.25
.010
SA type
7.24
.285
0.65
.026
5.08
.200
9.4 0.5
0.5
5.08
.200
.020
2.54
.100
.370 .020
15
.591
7.4
5.08 2.54
.291
.100
.200
1
.039
3.16
.124
8.2
.323
Max.10
.394
SL type
0.25
.010
0.65
.026
7.24
.285
5.08
.200
9.4 0.5
0.5
5.08
.200
.020
2.54
.100
.370 .020
15
.591
7.4
5.08 2.54
.291
.100
.200
1
.039
2.16
.085
8.2
.323
Max.10
.394
SS type
0.25
.010
6.24
.246
0.65
.026
5.08
.200
7.4 0.5
0.5
.020
5.08
.200
2.54
.100
.291 .020
Schematic (Top view)
Single side stable
1 coil latching
12
10
9
8
12
10
9
8
5
−
+
−
+
1
3
4
5
1
3
4
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
2. Surge breakdown voltage 6,000 V (High breakdown voltage type)
1) Standard PC board terminal
External dimensions
Standard PC board terminal
PC board pattern
(Bottom view)
Schematic (Bottom view)
CAD Data
Single side stable
1 coil latching
1
3
4
5
1
3
4
5
8
10.16
7.40
.291
.400
2.54
+
−
+
.100
15.00
.591
5.08
.200
−
12
10
9
8
12
10 9
0.65
9.45
Direction indication
Direction indication
.026
.372
8-1.0 dia.
8-.039 dia.
(Deenergized condition)
(Reset condition)
0.50
Tolerance: 0.1 .004
.020
0.25
.010
1.15 5.08
.045 .200
2.54
.100
3.50
.138
5.08
.200
General tolerance: 0.3 .012
2) Surface-mount terminal
CAD Data
External dimensions (General tolerance: 0.3 .012)
Single side stable and 1 coil latching
Suggested mounting pad (Top view) (Tolerance: 0.1 .004)
Single side stable and 1 coil latching
Type
7.40
.291
5.08 2.54
.100
.200
1
.039
15.00
.591
3.16
.124
0.25
SA type
9.45
.372
9.65
.380
.010
7.24
.285
0.65
.026
5.08
.200
0.50
.020
1.15
.045
5.08
.200
2.54
.100
9.40 0.5
.370 .020
7.40
.291
5.08 2.54
.100
.200
15.00
.591
1
.039
3.16
.124
9.45
SL type
0.25
Max. 11.25
.443
.372
.010
7.24
.285
0.65
.026
5.08
.200
0.50
.020
5.08
.200
1.15
2.54
.100
9.40 0.5
.045
.370 .020
7.40
.291
5.08 2.54
15.00
.591
.100
.200
1
.039
2.16
.085
9.45
0.25
Max. 11.25
.443
SS type
.372
.010
6.24
.246
0.65
5.08
.200
0.50
.020
.026
5.08
.200
1.15
2.54
.100
.045
7.40 0.5
.291 .020
Schematic (Top view)
Single side stable
1 coil latching
12
10
9
8
12
10
9
8
5
−
+
−
+
1
3
4
5
1
3
4
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
Partly Order Discontinued as of August 31, 2011
TX-D
NOTES
1. Packing style
(2) Dimensions of plastic reel
3. M.B.B. type
mm inch
1) Tube packing
A small OFF time may be generated by
the contact bounce during contact
switching. Check the actual circuit
carefully.
If the relay is dropped accidentally, check
the appearance and characteristics
including M.B.B. time before use.
The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
21 0.6 dia.
.827 .024 dia.
0.5
2.0
.020
.079
Orientation (indicates PIN No.1) stripe
80 1 dia.
3.150 .039 dia.
380 2 dia.
14.961 .079 dia.
Min. 10µs
13 0.5 dia.
Stopper (gray)
Stopper (green)
.512 .020 dia.
24.4+02
2.0 0.2
.961+0.079
2) Tape and reel packing (surface-mount
terminal type)
(1) Tape dimensions
(i) SA type
.079 .008
3) Ambient temperature when
transporting and during storage with the
product in its original packaging:
–40 to +70°C –40 to +158°F
500Ω
mm inch
5V DC
1.5+0.1 dia.
0
.059+.004 dia.
Relay polarity bar
(Z type)
2. Automatic insertion
1.75
.069
0
0.4
.016
2.0
4.0
.079 .157
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Measuring condition of M.B.B. time
C
A
B
11.5
.453
15.5
.610
10.0 .D394
16.0
.630
0.3
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
24.0
.945
9.2 0.2
TX-D relays
.012
C
.362 .008
B
A
Tape coming out direction
(ii) SL type
mm inch
1.5+0.1 dia.
0
Relay polarity bar
(Z type)
.059+.004 dia.
1.75
.069
0
0.4
.016
2.0
4.0
.079 .157
Chucking pressure in the direction A:
4.9 N {500gf} or less
Chucking pressure in the direction B:
9.8 N {1 kgf} or less
Chucking pressure in the direction C:
9.8 N {1 kgf} or less
11.5
.453
15.5
.610
0.3
16.0
.630
24.0
.945
.012
TX-D relays
10.0
.394
10.8 0.2
.425 .008
Tape coming out direction
(iii) SS type
Please chuck the
portion.
mm inch
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be
avoided.
1.5+0.1 dia.
0
.059+.004 dia.
Relay polarity bar
(Z type)
2.0
4.0
1.75
.069
0
0.4
.016
.079 .157
11.5
.453
15.5
.610
0.3
16.0
.630
8.0 24.0
.01210.8 0.2
.425 .008
TX-D relays
.945
.315
Tape coming out direction
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.
相关型号:
TXD2-L-9V-1-X
Electromechanical Relay, DPDT, 10.8VDC (Coil), 1A (Contact), 220VDC (Contact), Random, DC Output,
PANASONIC
TXD2-L-9V-1-Z
Electromechanical Relay, DPDT, 10.8VDC (Coil), 1A (Contact), 220VDC (Contact), Random, DC Output,
PANASONIC
TXD2-L-9V-3
Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-9V-4
Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-9V-6
Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-9V-7
Power/Signal Relay, DPDT, Latched, 0.026A (Coil), 9VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-9V-X
Electromechanical Relay, DPDT, 10.8VDC (Coil), 2A (Contact), 220VDC (Contact), Random, DC Output,
PANASONIC
TXD2-L-H-1.5V
Power/Signal Relay, DPDT, Latched, 0.153A (Coil), 1.5VDC (Coil), 230mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-H-1.5V-6
Power/Signal Relay, DPDT, Latched, 0.153A (Coil), 1.5VDC (Coil), 230mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-H-1.5V-7
Power/Signal Relay, DPDT, Latched, 0.153A (Coil), 1.5VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-H-12V-1
Power/Signal Relay, DPDT, Latched, 0.019A (Coil), 12VDC (Coil), 230mW (Coil), 1A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
TXD2-L-H-12V-6
Power/Signal Relay, DPDT, Latched, 0.019A (Coil), 12VDC (Coil), 230mW (Coil), 2A (Contact), 220VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明