JJM1-12V [PANASONIC]

COMPACT SIZE AUTOMOTIVE RELAY; 紧凑的尺寸汽车继电器
JJM1-12V
型号: JJM1-12V
厂家: PANASONIC    PANASONIC
描述:

COMPACT SIZE AUTOMOTIVE RELAY
紧凑的尺寸汽车继电器

继电器 功率继电器 信号继电器 光电二极管 PC
文件: 总4页 (文件大小:96K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
COMPACT SIZE  
AUTOMOTIVE RELAY  
JJ-M RELAYS  
FEATURES  
Compact (half-size).  
Standard terminal pitch employed  
The terminal array used is identical to  
that used in small automotive relays.  
The base area is approximately half the  
size of conventional (JS-M) relays. The  
controller unit can be made more  
compact.  
12  
.472  
15.5  
.610  
Plastic sealed type.  
Plastically sealed for automatic cleaning.  
13.9  
.547  
Base area has been reduced by one half  
Line-up of 1 Form A and 1 Form C.  
16  
.630  
12  
.472  
TYPICAL APPLICATIONS  
Power windows  
mm inch  
22  
.866  
JSM  
15.5  
Auto door lock  
.610  
JJM  
Electrically powered sun roof  
Electrically powered mirror  
Cornerring lamp, etc.  
Perfect for automobile electrical  
systems.  
Over 2 × 105 openings possible with a 14  
V DC motor load, an inrush current of 25  
A, and steady state current of 5 A.  
(N.O. side)  
Compliance with RoHS Directive  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
1 Form A  
1 Form C  
Max. operating speed (at rated load)  
6 cpm  
Contact material  
Ag alloy (Cadmium free)  
Typ. 5 m  
20 A 14 V DC  
Min. 100 MΩ  
Initial insulation resistance*9  
(at 500 V DC)  
Initial contact resistance (Initial)  
(By voltage drop 6V DC 1A)  
Between open contacts  
Between contact and coil  
500 Vrms for 1min.  
500 Vrms for 1min.  
Initial breakdown  
voltage*10  
Nominal switching  
capacity  
(N.O.)  
10 A 14 V DC  
(N.C.)  
Max. 10 ms  
(at 20°C 68°F)  
Max. 10 ms  
(at 20°C 68°F)  
20 A 14 V DC  
Operate time*11 (at nominal voltage)  
Release time (without diode)*11  
(at nominal voltage) (Initial)  
Rating  
Min. switching  
(resistive  
capacity#1  
load)  
1 A 12 V DC  
Functional*12  
Min. 100 m/s2 {10 G}  
Destructive*13 Min. 1,000 m/s2 {100 G}  
N.O.: 35 A (12V, at 20°C 68°F for 2 minutes)  
25 A (12V, at 20°C 68°F for 1 hour)  
30 A (12V, at 85°C 185°F for 2 minutes)  
20 A (12V, at 85°C 185°F for 1 hour)  
Shock resistance  
Max. carrying  
current  
10 Hz to 100 Hz,  
Functional*14  
Min. 44.1 m/s2 {4.5 G}  
Vibration resistance  
Mechanical  
(at 120cpm)  
10 Hz to 500 Hz,  
Destructive  
107  
Min. 44.1 m/s2 {4.5 G}  
Expected  
Resistive  
105 (N.O.)*2  
105 *1  
Conditions in case of opera- Ambient  
tion, transport and storage*15 temp.  
(Not freezing and condens-  
40°C to +85°C  
40°F to +185°F  
life (min.  
Electrical  
105 (N.C.)*3  
operations)  
2×105 (N.O.)*6  
(at rated  
load)  
2×105 *4  
Humidity  
5% R.H. to 85% R.H.  
Approx. 5 g .176 oz  
Motor  
load  
ing at low temperature)  
5×104 (N.O.)*7  
5×104 *5  
2×105 (N.C.)*8  
Mass  
7
*
*
*
*
*
*
*
*
*
at 20 A 14 V DC (Motor lock)  
Coil  
8
at peak 20 A 14 V DC (Braking current) operating frequency: 0.5 s ON, 9.5 s OFF  
Measurement at same location as Initial break down voltagesection.  
Detection current: 10mA  
Excluding contact bounce time.  
Half-wave pulse of sine wave: 11 ms; detection time: 10 µs  
Half-wave pulse of sine wave: 6 ms  
Detection time: 10 µs  
Refer to Conditions for operation, transport and storage mentioned in AMBIENT  
ENVIRONMENT  
9
Nominal operating power  
640 mW  
10  
11  
12  
13  
14  
15  
#1 This value can change due to the switching frequency, environmental conditions,  
and desired reliability level, therefore it is recommended to check this with the  
actual load.  
Remarks  
1
*
*
*
*
*
*
at 20 A 14 V DC, at 20 cpm, operating frequency: 1s ON, 9s OFF  
at 20 A 14 V DC, operating frequency: 1s ON, 9s OFF  
at 10 A 14 V DC, at 20 cpm, operating frequency: 1s ON, 9s OFF  
at 5 A (steady), 25 A (inrush) 14 V DC  
at 20 A 14 V DC (Motor lock), operating frequency: 0.5 s ON, 9.5 s OFF  
at 5A (steady), 25 A (inrush) 14 V DC  
Please inquire if you will be using the relay in a high temperature atmosphere  
(110°C 230°F).  
2
3
4
5
6
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
JJ-M  
ORDERING INFORMATION  
Ex. JJM  
Contact arrangement  
Coil voltage(DC)  
12 V  
1a: 1 Form A  
1: 1 Form C  
(Note) Standard packing: Carton: 50 pcs.; Case: 1,000 pcs.  
TYPES AND COIL DATA (at 20°C 68°F)  
Nominal Pick-up voltage, Drop-out voltage,  
Contact  
Nominal  
Nominal  
Usable  
Coil resistance  
Part No.  
voltage,  
V DC  
V DC  
(Initial)  
V DC  
(Initial)  
operating current operating power voltagerange,  
arrangement  
mA  
mW  
640  
640  
V DC  
1 Form A  
1 Form C  
JJM1a-12 V  
JJM1-12 V  
12  
12  
Max. 7.2  
Max. 7.2  
Min. 1.0  
Min. 1.0  
225 10%  
225 10%  
53.3 10%  
53.3 10%  
10 to 16  
10 to 16  
* Other pick-up voltage types are also available. Please contact us for details.  
mm inch  
DIMENSIONS  
Schematic (Bottom view)  
1a  
PC board pattern (Bottom view)  
1a  
15.5  
.610  
12  
.472  
3-1.4 dia.  
3-.055 dia.  
NO  
COM  
13.9  
.547  
COIL  
10.0  
.394  
1.5 dia.  
.059 dia.  
0.4  
.016  
3.5  
.138  
2.5  
.098  
10.2  
.402  
A  
2-0.3  
2-.012  
2-0.4  
2-.016  
1c  
1c  
4-1.4 dia.  
4-.055 dia.  
10.0 1.2  
.394 .047  
NO  
COM  
COIL  
NC  
0.3  
.012  
2.5  
.098  
4-1.0  
10.0  
.394  
1.5 dia.  
.059 dia.  
4-.039  
0.3  
10.2  
.402  
1.6  
.012  
.063  
2.5  
.098  
10.2  
.402  
Note: Marked terminal is only for 1Form C type  
* Dimensions (thickness and width) of terminal specied in this catalog  
is measured before pre-soldering.  
Intervals between terminals is measured at A surface level.  
Tolerance: 0.1 .004  
Dimension:  
Max. 1mm .039 inch:  
General tolerance  
0.1 .004  
1 to 3mm .039 to .118 inch: 0.2 .008  
Min. 3mm .118 inch: 0.3 .012  
REFERENCE DATA  
1. Coil temperature rise  
2. Max. switching capability (Resistive load)  
3. Ambient temperature and operating voltage  
range  
Sample: JJM1-12V, 6pcs  
Point measured: Inside the coil  
Contact current: Now current through  
contact, 5A, 10A, 15A, 20A  
Resistance method, ambient temperature 85°C 185°F  
(N.O. side: room temperature)  
60  
120  
40  
35  
20A  
100  
80  
50  
40  
30  
25  
20  
15  
10  
15A  
10A  
5A  
60  
40  
20  
0
30  
20  
Non current  
through  
contact  
10  
0
5
Pick-up voltage  
(cold start)  
0
12  
14  
16  
0
10  
20  
30  
40  
50  
40 20  
0
20 40 60 8085 100 120  
Switching current, A  
Ambient temperature, °C  
Coil applied voltage, V  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
JJ-M  
4. Distribution of pick-up and drop-out voltage  
Sample: JJM1-12V, 100pcs  
5. Distribution of operate time  
Sample: JJM1-12V, 100pcs  
6. Distribution of release time  
Sample: JJM1-12V, 100pcs  
* With diode  
70  
60  
50  
40  
30  
20  
10  
0
70  
70  
60  
50  
40  
30  
20  
10  
0
Pick-up voltage  
Drop-out voltage  
60  
50  
40  
30  
20  
10  
0
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0  
Time, ms  
1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0  
0
0.5 1.01.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5  
Voltage, V  
Time, ms  
7-(1). Electrical life test (at rated load)  
Sample: JJM1-12V  
Quantity: n = 6 (NC = 3, NO = 3)  
Load:Resisitive load (NC side:10A 14V DC, NO side:  
20 A 14 V DC); Operating frequency: ON 1s, OFF 9s  
Ambient temperature: Room temperature  
7
Contact welding: 0 time  
Miscontact: 0 time  
Max.  
X
Min.  
6
5
4
Pick-up voltage  
3
Drop-out voltage  
Max.  
2
1
0
X
Min.  
0
5
10  
No. of operations, × 104  
7-(2). Electrical life test (Motor free)  
Sample: JJM1-12V, 6pcs.  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Load: 5A, Inrush 25A, Brake current 18A 14V DC,  
Power window motor load (Free condition).  
Operating frequency: (ON : OFF = 0.5s : 9.5s)  
Ambient temperature: Room temperature  
50  
40  
30  
8
Contact welding: 0 time  
N.C. side  
N.O. side  
Miscontact: 0 time  
7
Max.  
X
Min.  
6
Circuit :  
5
Pick-up voltage  
Tested sample  
4
20  
Max.  
Drop-out voltage  
3
2
1
0
Max.  
X
X(N.C.)  
Min.  
Min.  
Max.  
X(N.O.)  
10  
0
Min.  
M
0
10  
No. of operations, × 104  
20  
0
5
10  
No. of operations, × 104  
7-(3). Electrical life test (Motor lock)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: JJM1-12V, 6pcs.  
Load: 20A, 14VDC,  
Power window motor actual load (lock condition).  
Operating frequency: (ON : OFF = 1s : 5s)  
Ambient temperature: Room temperature  
50  
40  
30  
7
Contact welding: 0 time  
N.C. side  
N.O. side  
Miscontact: 0 time  
6
Max.  
X
Min.  
5
4
3
2
Pick-up voltage  
Drop-out voltage  
Circuit :  
Tested sample  
Max.  
X
20  
10  
0
Min.  
Max.  
Max.  
X(N.C.)  
X(N.O.)  
Min.  
1
0
M
0
2.5  
No. of operations, × 104  
5
0
2.5  
5
No. of operations, × 104  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  
JJ-M  
7-(4). Electrical life test (Lamp load)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
Sample: JJM1-12V, 6pcs.  
Load: 27W+21W, min. 4A (steady), Lamp actual load  
Operating frequency: ON 2s, OFF 13s  
Ambient temperature: Room temperature  
10  
9
50  
40  
N.C. side  
N.O. side  
8
Pick-up voltage  
Drop-out voltage  
7
6
Max.  
X
Circuit :  
30  
20  
Min.  
5
4
3
2
Max.  
Max.  
Max.  
X
Min.  
10  
0
X(N.O.)  
X(N.C)  
Min.  
1
0
Min.  
0
5
10  
0
5
10  
No. of operations, × 104  
No. of operations, × 104  
Inrush current: 42A, Steady current: 4.4A  
10A  
10ms  
For Cautions for Use, see Relay Technical Information .  
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.  

相关型号:

JJM1A-12V

COMPACT SIZE AUTOMOTIVE RELAY
PANASONIC

JJM2W-12V

DOUBLE MAKE CONTACT AUTOMOTIVE RELAY
NAIS

JJN-1

Fuse
ETC

JJN-10

T-Tron® Very Fast Acting Fuses
COOPER

JJN-100

Electric Fuse, Very Fast Blow, 100A, 300VAC, 160VDC, 200000A (IR), Inline/holder
COOPER

JJN-1000

Electric Fuse, Very Fast Blow, 1000A, 300VAC, 170VDC, 200000A (IR), Inline/holder
COOPER

JJN-110

Electric Fuse, Very Fast Blow, 110A, 300VAC, 160VDC, 200000A (IR), Inline/holder
COOPER

JJN-1200

Electric Fuse, Very Fast Blow, 1200A, 300VAC, 170VDC, 200000A (IR), Inline/holder
COOPER

JJN-125

Electric Fuse, Very Fast Blow, 125A, 300VAC, 160VDC, 200000A (IR), Inline/holder
COOPER

JJN-15

Electric Fuse, Very Fast Blow, 15A, 300VAC, 160VDC, 200000A (IR), Inline/holder
COOPER

JJN-150

Electric Fuse, Very Fast Blow, 150A, 300VAC, 160VDC, 200000A (IR), Inline/holder
COOPER

JJN-175

Electric Fuse, Very Fast Blow, 175A, 300VAC, 160VDC, 200000A (IR), T, Inline/holder,
COOPER