FEATURES  
• 35A/48A current at 250 V AC  
achieved in compact size (L: 33 × W:  
38 × H: 36.3 mm L: 1.299 × W: 1.496 ×  
H: 1.429 inch)  
• High insulation and 10,000 V surge  
breakdown voltage (between contacts  
and coil) achieved.  
• Conforms to various safety  
standards  
Due to improved conduction efficiency,  
wide terminal blades are used. (for high  
capacity type)  
UL/C-UL and VDE  
TYPICAL APPLICATIONS  
• Photovoltaic power generation  
systems (Solar inverter)  
RoHS compliant  
• Contact gap: 2.5 mm (VDE0126  
compliant)  
Compliant with European photovoltaic  
standard VDE0126  
Compliant with EN61810-1 2.5 kV surge  
breakdown voltage (between contacts)  
• Contributes to energy saving in  
devices thanks to reduced coil hold  
voltage  
Coil hold voltage can be reduced down to  
40% of the nominal coil voltage (ambient  
temperature 20°C 68°F). This equals to  
operating power of approximately 310  
mW.  
*Coil hold voltage is the coil voltage after  
100 ms following application of the  
nominal coil voltage.  
ORDERING INFORMATION  
HE 1a  
N
P
DC  
Contact arrangement  
1a: 1 Form A (Single side stable type)  
Pick-up voltage  
N: 70% of nominal voltage  
Terminals  
P: PC board terminal type  
Coil voltage (DC)  
6, 9, 12, 24V  
Type, contact material and switching capacity  
Y5: PV type, AgNi type (1 Form A 48A high capacity)  
H18: PV type, AgSnO2 type (1 Form A 35A standard)  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2013  
ASCTB101E 201307-T  
2013.07  
–1–  
HE PV Type  
TYPES  
Standard type*  
Part No.  
High capacity type  
Part No.  
Nominal coil  
voltage  
6V DC  
9V DC  
HE1aN-P-DC6V-H18  
HE1aN-P-DC9V-H18  
HE1aN-P-DC12V-H18  
HE1aN-P-DC24V-H18  
HE1aN-P-DC6V-Y5  
HE1aN-P-DC9V-Y5  
HE1aN-P-DC12V-Y5  
HE1aN-P-DC24V-Y5  
12V DC  
24V DC  
Standard packing: Carton: 20 pcs.; Case: 100 pcs.  
*Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE)  
RATING  
1. Coil data  
Pick-up voltage  
(at 20°C 68°F)  
(Initial)  
Drop-out voltage  
(at 20°C 68°F)  
(Initial)  
Nominal operating  
current  
[ 10%] (at 20°C 68°F)  
Nominal coil  
voltage  
Coil resistance  
[ 10%] (at 20°C 68°F)  
Nominal operating  
power  
Max. applied voltage  
(at 20°C 68°F)  
6V DC  
9V DC  
320mA  
213mA  
160mA  
80mA  
18.8Ω  
42.2Ω  
75.0Ω  
70%V or less of  
nominal voltage  
10%V or more of  
nominal voltage  
110%V of  
nominal voltage  
1,920mW  
12V DC  
24V DC  
300.0Ω  
2. Specifications  
Specifications  
Characteristics  
Item  
Standard type  
High capacity type  
Arrangement  
1 Form A  
Max. 100 m(By voltage drop 6 V DC 1A)  
AgSnO2 type AgNi type  
Contact  
Rating  
Contact resistance (Initial)  
Contact material  
Nominal switching capacity  
Contact carring power  
Max. switching voltage  
Max. switching current  
Nominal operating power  
35 A 250 V AC (Resistive load)  
8,750 VA (Resistive load)  
48 A 250 V AC (Resistive load)  
12,000 VA (Resistive load)  
250 V AC  
35 A (AC)  
48 A (AC)  
1,920 mW  
Min. switching capacity (Reference value)*1  
100 mA 5 V DC  
Insulation resistance (Initial)  
Min. 1,000M(at 500V DC) Measurement at same location as “Breakdown voltage” section.  
2,000 Vrms for 1 min. (Detection current: 10 mA)  
Between open contacts  
Between contact and coil  
Breakdown  
voltage (Initial)  
5,000 Vrms for 1 min. (Detection current: 10 mA)  
Surge breakdown voltage*2  
(Between contact and coil) (Initial)  
10,000 V  
Max. 60°C 140°F (By resistive method,  
Max. 60°C 140°F (By resistive method,  
contact carrying current: 35A, 100%V of nominal contact carrying current: 48A, 100%V of nominal  
coil voltage at 55°C 131°F.)  
coil voltage at 55°C 131°F.)  
Temperature rise  
Coil hold voltage*3  
Max. 30°C 86°F (By resistive method, contact  
carrying current: 35A, 60%V of nominal coil  
voltage at 85°C 185°F.)  
Max. 30°C 86°F (By resistive method, contact  
carrying current: 48A, 60%V of nominal coil  
voltage at 85°C 185°F.)  
Electrical  
characteristics  
40 to 100%V (Contact carrying current:  
35A, at 20°C 68°F),  
40 to 100%V (Contact carrying current:  
48A, at 20°C 68°F),  
50 to 100%V (Contact carrying current:  
35A, at 55°C 131°F),  
50 to 100%V (Contact carrying current:  
48A, at 55°C 131°F),  
50 to 60%V (Contact carrying current:  
35A, at 85°C 185°F)  
50 to 60%V (Contact carrying current:  
48A, at 85°C 185°F)  
Operate time (at 20°C 68°F)  
Release time (at 20°C 68°F)*5  
Functional  
Shock  
Max. 30 ms (nominal coil voltage, excluding contact bounce time)  
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)  
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.)  
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)  
resistance  
Destructive  
Functional  
Destructive  
Mechanical  
characteristics  
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs.)  
10 to 55 Hz at double amplitude of 1.5 mm  
Vibration  
resistance  
Mechanical  
Min. 106 (at 180 times/min.)  
Resistive load  
Inductive load  
Min. 3×104 (35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×104 (48 A 250 V AC) (ON : OFF = 1s : 9s)  
Endurance: 48 A 250 V AC (cosφ = 0.8),  
Expected life  
Min. 3×104 (ON : OFF = 0.1s : 10s)  
Electrical  
Overload: 72 A 250 V AC (cosφ = 0.8),  
Min. 50 (ON : OFF = 0.1s : 10s)  
Ambient temperature:  
–50 to +55°C –58 to +131°F (When nominal coil voltage applied)  
–50 to +85°C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);  
Atmospheric pressure: 86 to 106 kPa  
Conditions for operation, transport and  
storage*4  
Conditions  
Unit weight  
Max. operating speed  
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)  
Approx. 80 g 2.82 oz  
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981  
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.  
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage  
conditions in NOTES.  
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.  
Panasonic Corporation Automation Controls Buisiness Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2013  
ASCTB101E 201307-T  
–2–  
HE PV Type  
REFERENCE DATA  
1.-(1) Coil temperature rise  
(Standard type)  
1.-(2) Coil temperature rise  
(High capacity type)  
Sample: HE1aN-P-DC9V-H18, 6 pcs.  
Point measured: coil inside  
Sample: HE1aN-P-DC9V-Y5, 6 pcs.  
Point measured: coil inside  
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C  
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C  
185°F  
185°F  
Contact carrying current: 35A  
Contact carrying current: 48A  
70  
70  
60  
60  
25°C  
25°C  
50  
40  
30  
20  
10  
0
50  
60°C  
85°C  
60°C  
40  
30  
20  
10  
0
85°C  
50  
60  
70  
80  
90  
100  
50  
60  
70  
80  
90  
100  
Coil applied voltage, %V  
Coil applied voltage, %V  
2.-(1) Electrical life test (Standard type, Resistive load 250V AC, 35A at 85°C 185°F)  
Sample: HE1aN-P-DC9V-H18, 6 pcs.  
Operation frequency: 6 times/min.  
(ON/OFF = 1.0s : 9.0s)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
9
8
7
6
100  
90  
80  
70  
60  
50  
40  
30  
20  
Circuit:  
Contact  
Pick-up voltage  
5
Max.  
x
welding  
detection  
and Mis-  
contacting  
detection  
circuit  
Min.  
250V AC  
4
3
9V DC  
Drop-out voltage  
Max.  
x
2
Min.  
Max.  
x
1
10  
0
Min.  
0
0
3
0
3
No. of operations, ×104  
No. of operations, ×104  
2.-(2) Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85°C 185°F)  
Sample: HE1aN-P-DC9V-Y5, 6 pcs.  
Operation frequency: 6 times/min.  
(ON/OFF = 1.0s : 9.0s)  
Change of pick-up and drop-out voltage  
Change of contact resistance  
9
8
7
6
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
Circuit:  
Contact  
welding  
detection  
and Mis-  
contacting  
detection  
circuit  
Pick-up voltage  
5
Max.  
x
Min.  
250V AC  
4
3
9V DC  
Drop-out voltage  
Max.  
x
2
Min.  
Max.  
x
1
Min.  
0
0
0
0
3
3
No. of operations, ×104  
No. of operations, ×104  
Panasonic Corporation Automation Controls Buisiness Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2013  
ASCTB101E 201307-T  
–3–  
HE PV Type  
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/  
DIMENSIONS (mm inch)  
CAD Data  
Standard type  
External dimensions  
Schematic (Bottom view)  
Single side stable type  
PC board pattern (Bottom view)  
38.0  
1.496  
33  
1.299  
24  
.945  
4.7  
.185  
1
4
8.4  
.331  
36.3  
1.429  
0.5  
18.6  
.732  
6-2 dia. hole  
6-.079 dia. hole  
6
5
.020  
4
32  
1.260  
.157  
4.7  
1.6  
1.6  
.063  
0.8  
.031  
.063  
.185  
0.8  
.031  
General tolerance: 0.3 .012  
Tolerance: 0.1 .004  
High capacity type  
External dimensions  
Schematic (Bottom view)  
Single side stable type  
PC board pattern (Bottom view)  
24  
38.0  
1.496  
33  
1.299  
.945  
6.5  
.256  
1
4
8.4  
.331  
36.3  
1.429  
18.6  
.732  
6
5
1.3  
.051  
0.5  
.020  
2-2 dia. hole  
2-.079 dia. hole  
4
.157  
32  
1.260  
0.8  
.031  
6.3  
.248  
1.6  
.063  
0.8  
.031  
General tolerance: 0.3 .012  
Tolerance: 0.1 .004  
SAFETY STANDARDS  
Certification body  
Contact rating  
48A 277V AC (at 85°C 185°F)  
*60A 277V AC (general use, at 60°C 140°F, 10k cycle), in use at 60% of rated coil voltage  
C-UL  
48A 250V AC cosφ = 0.8 (at 85°C 185°F)  
*72A 250V AC (cosφ = 0.8 at 85°C 185°F, 50 cycle)  
*60A 250V AC (cosφ = 0.8 at 85°C 185°F, 10k cycle)  
*50A 20V DC (0ms, at 85°C 185°F, 30k cycle)  
High capacity type  
VDE (VDE0435)  
UL/CSA  
Standard type  
35A 277V AC (at 25°C 77°F)  
35A 250V AC cosφ = 1 (at 80°C 176°F)  
VDE (VDE0435)**  
* Under development. Please contact us.  
** Only 9V DC type is Certified by VDE  
Panasonic Corporation Automation Controls Buisiness Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2013  
ASCTB101E 201307-T  
–4–  
HE PV Type  
NOTES  
Usage, transport and storage  
conditions  
Temperature and humidity range for  
usage, transport, and storage  
Certification  
This relay is UL/C-UL certified.  
48 A 277 V AC (High capacity type)  
35 A 277 V AC (Standard type)  
This relay is certified by VDE  
48 A 250 V AC cosφ = 0.8  
(High capacity type)  
1) Temperature:  
Humidity, %RH  
–50 to +55°C –58 to +131°F  
–50 to +85°C –58 to +185°F (When  
applied coil hold voltage is 50% to 60% of  
nominal coil voltage)  
85  
Tolerance range  
(Avoid freezing (Avoid  
when used at condensation  
2) Humidity: 5 to 85% RH  
35 A 250 V AC cosφ = 1  
(Standard type)  
temperatures  
lower than  
0°C 32°F)  
when used at  
temperatures  
higher than  
0°C 32°F)  
(Avoid freezing and condensation.)  
The humidity range varies with the  
temperature. Use within the range  
indicated in the graph below.  
3) Atmospheric pressure: 86 to 106 kPa  
5
–50  
–58  
0
+32  
55  
+131  
Temperature, °C °F  
Humidity, %RH  
85  
Tolerance range  
(Avoid freezing (Avoid  
when used at condensation  
temperatures  
lower than  
0°C 32°F)  
when used at  
temperatures  
higher than  
0°C 32°F)  
5
–50  
–58  
0
+32  
85  
+185  
Temperature, °C °F  
–50 to +85°C –58 to +185°F (When applied  
coil hold voltage is 50% to 60% of nominal  
coil voltage)  
Panasonic Corporation Automation Controls Buisiness Division  
industrial.panasonic.com/ac/e/  
© Panasonic Corporation 2013  
ASCTB101E 201307-T  
–5–  

相关型号:

HE1AN-P-DC24V

TV-15, 30 AMP (1 Form A) Power Relay
NAIS

HE1AN-P-DC24V

TV-10/TV-15 rated 1a 30A, 2a 20A power relays High-capacity and long life
PANASONIC

HE1AN-P-DC24V-H18

Ideal for solar inverter compact size, 1a 35a/48a power relays
PANASONIC

HE1AN-P-DC48V

TV-15, 30 AMP (1 Form A) Power Relay
NAIS

HE1AN-P-DC48V

TV-10/TV-15 rated 1a 30A, 2a 20A power relays High-capacity and long life
PANASONIC

HE1AN-P-DC6V

TV-15, 30 AMP (1 Form A) Power Relay
NAIS

HE1AN-P-DC6V

TV-10/TV-15 rated 1a 30A, 2a 20A power relays High-capacity and long life
PANASONIC

HE1AN-P-DC6V-H18

Ideal for solar inverter compact size, 1a 35a/48a power relays
PANASONIC

HE1AN-P-DC9V-H18

Ideal for solar inverter compact size, 1a 35a/48a power relays
PANASONIC

HE1AN-Q-AC100V

TV-10/TV-15 rated 1a 30A, 2a 20A power relays High-capacity and long life
PANASONIC

HE1AN-Q-AC120V

TV-15, 30 AMP (1 Form A) Power Relay
NAIS

HE1AN-Q-AC120V

Power/Signal Relay, SPST, Momentary, 2700mW (Coil), 30A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Panel Mount, ROHS COMPLIANT
PANASONIC