Ideal for solar inverter compact size, 1a 35a/48a power relays; 非常适合太阳能逆变器体积小巧, 1A 35A / 48A功率继电器型号: | HE1AN-P-DC12V-Y5 |
厂家: | PANASONIC |
描述: | Ideal for solar inverter compact size, 1a 35a/48a power relays |
文件: | 总5页 (文件大小:92K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Automation Controls Catalog
VDE
Ideal for solar inverter
HE RELAYS
PV Type
compact size,
1a 35A/48A power relays
FEATURES
• 35A/48A current at 250 V AC
achieved in compact size (L: 33 × W:
38 × H: 36.3 mm L: 1.299 × W: 1.496 ×
H: 1.429 inch)
• High insulation and 10,000 V surge
breakdown voltage (between contacts
and coil) achieved.
• Conforms to various safety
standards
Due to improved conduction efficiency,
wide terminal blades are used. (for high
capacity type)
UL/C-UL and VDE
TYPICAL APPLICATIONS
• Photovoltaic power generation
systems (Solar inverter)
RoHS compliant
• Contact gap: 2.5 mm (VDE0126
compliant)
Compliant with European photovoltaic
standard VDE0126
Compliant with EN61810-1 2.5 kV surge
breakdown voltage (between contacts)
• Contributes to energy saving in
devices thanks to reduced coil hold
voltage
Coil hold voltage can be reduced down to
40% of the nominal coil voltage (ambient
temperature 20°C 68°F). This equals to
operating power of approximately 310
mW.
*Coil hold voltage is the coil voltage after
100 ms following application of the
nominal coil voltage.
ORDERING INFORMATION
HE 1a
N
P
DC
Contact arrangement
1a: 1 Form A (Single side stable type)
Pick-up voltage
N: 70% of nominal voltage
Terminals
P: PC board terminal type
Coil voltage (DC)
6, 9, 12, 24V
Type, contact material and switching capacity
Y5: PV type, AgNi type (1 Form A 48A high capacity)
H18: PV type, AgSnO2 type (1 Form A 35A standard)
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2013
ASCTB101E 201307-T
2013.07
–1–
HE PV Type
TYPES
Standard type*
Part No.
High capacity type
Part No.
Nominal coil
voltage
6V DC
9V DC
HE1aN-P-DC6V-H18
HE1aN-P-DC9V-H18
HE1aN-P-DC12V-H18
HE1aN-P-DC24V-H18
HE1aN-P-DC6V-Y5
HE1aN-P-DC9V-Y5
HE1aN-P-DC12V-Y5
HE1aN-P-DC24V-Y5
12V DC
24V DC
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
*Standard 6V, 12V and 24V DC type: Certified by UL/C-UL (Standard 9V type: Certified by UL/C-UL and VDE)
RATING
1. Coil data
Pick-up voltage
(at 20°C 68°F)
(Initial)
Drop-out voltage
(at 20°C 68°F)
(Initial)
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal coil
voltage
Coil resistance
[ 10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
6V DC
9V DC
320mA
213mA
160mA
80mA
18.8Ω
42.2Ω
75.0Ω
70%V or less of
nominal voltage
10%V or more of
nominal voltage
110%V of
nominal voltage
1,920mW
12V DC
24V DC
300.0Ω
2. Specifications
Specifications
Characteristics
Item
Standard type
High capacity type
Arrangement
1 Form A
Max. 100 mΩ (By voltage drop 6 V DC 1A)
AgSnO2 type AgNi type
Contact
Rating
Contact resistance (Initial)
Contact material
Nominal switching capacity
Contact carring power
Max. switching voltage
Max. switching current
Nominal operating power
35 A 250 V AC (Resistive load)
8,750 VA (Resistive load)
48 A 250 V AC (Resistive load)
12,000 VA (Resistive load)
250 V AC
35 A (AC)
48 A (AC)
1,920 mW
Min. switching capacity (Reference value)*1
100 mA 5 V DC
Insulation resistance (Initial)
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
2,000 Vrms for 1 min. (Detection current: 10 mA)
Between open contacts
Between contact and coil
Breakdown
voltage (Initial)
5,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown voltage*2
(Between contact and coil) (Initial)
10,000 V
Max. 60°C 140°F (By resistive method,
Max. 60°C 140°F (By resistive method,
contact carrying current: 35A, 100%V of nominal contact carrying current: 48A, 100%V of nominal
coil voltage at 55°C 131°F.)
coil voltage at 55°C 131°F.)
Temperature rise
Coil hold voltage*3
Max. 30°C 86°F (By resistive method, contact
carrying current: 35A, 60%V of nominal coil
voltage at 85°C 185°F.)
Max. 30°C 86°F (By resistive method, contact
carrying current: 48A, 60%V of nominal coil
voltage at 85°C 185°F.)
Electrical
characteristics
40 to 100%V (Contact carrying current:
35A, at 20°C 68°F),
40 to 100%V (Contact carrying current:
48A, at 20°C 68°F),
50 to 100%V (Contact carrying current:
35A, at 55°C 131°F),
50 to 100%V (Contact carrying current:
48A, at 55°C 131°F),
50 to 60%V (Contact carrying current:
35A, at 85°C 185°F)
50 to 60%V (Contact carrying current:
48A, at 85°C 185°F)
Operate time (at 20°C 68°F)
Release time (at 20°C 68°F)*5
Functional
Shock
Max. 30 ms (nominal coil voltage, excluding contact bounce time)
Max. 10 ms (nominal coil voltage, excluding contact bounce time) (without diode)
Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
resistance
Destructive
Functional
Destructive
Mechanical
characteristics
10 to 55 Hz at double amplitude of 1.0 mm (Detection time: 10 µs.)
10 to 55 Hz at double amplitude of 1.5 mm
Vibration
resistance
Mechanical
Min. 106 (at 180 times/min.)
Resistive load
Inductive load
Min. 3×104 (35 A 250 V AC) (ON : OFF = 1s : 9s) Min. 3×104 (48 A 250 V AC) (ON : OFF = 1s : 9s)
Endurance: 48 A 250 V AC (cosφ = 0.8),
Expected life
Min. 3×104 (ON : OFF = 0.1s : 10s)
Electrical
—
Overload: 72 A 250 V AC (cosφ = 0.8),
Min. 50 (ON : OFF = 0.1s : 10s)
Ambient temperature:
–50 to +55°C –58 to +131°F (When nominal coil voltage applied)
–50 to +85°C –58 to +185°F (When applied coil hold voltage is 50% to 60% of nominal coil voltage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature);
Atmospheric pressure: 86 to 106 kPa
Conditions for operation, transport and
storage*4
Conditions
Unit weight
Max. operating speed
6 times/min. (at nominal switching capacity ON : OFF = 1s : 9s)
Approx. 80 g 2.82 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2×50µs according to JEC-212-1981
*3. Coil hold voltage is the coil voltage after 100 ms following application of the nominal coil voltage.
*4. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*5. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2013
ASCTB101E 201307-T
–2–
HE PV Type
REFERENCE DATA
1.-(1) Coil temperature rise
(Standard type)
1.-(2) Coil temperature rise
(High capacity type)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Point measured: coil inside
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Point measured: coil inside
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
Ambient temperature: 25°C 77°F, 60°C 140°F, 85°C
185°F
185°F
Contact carrying current: 35A
Contact carrying current: 48A
70
70
60
60
25°C
25°C
50
40
30
20
10
0
50
60°C
85°C
60°C
40
30
20
10
0
85°C
50
60
70
80
90
100
50
60
70
80
90
100
Coil applied voltage, %V
Coil applied voltage, %V
2.-(1) Electrical life test (Standard type, Resistive load 250V AC, 35A at 85°C 185°F)
Sample: HE1aN-P-DC9V-H18, 6 pcs.
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Change of pick-up and drop-out voltage
Change of contact resistance
9
8
7
6
100
90
80
70
60
50
40
30
20
Circuit:
Contact
Pick-up voltage
5
Max.
x
welding
detection
and Mis-
contacting
detection
circuit
Min.
250V AC
4
3
9V DC
Drop-out voltage
Max.
x
2
Min.
Max.
x
1
10
0
Min.
0
0
3
0
3
No. of operations, ×104
No. of operations, ×104
2.-(2) Electrical life test (High capacity type, Resistive load 250V AC, 48A at 85°C 185°F)
Sample: HE1aN-P-DC9V-Y5, 6 pcs.
Operation frequency: 6 times/min.
(ON/OFF = 1.0s : 9.0s)
Change of pick-up and drop-out voltage
Change of contact resistance
9
8
7
6
100
90
80
70
60
50
40
30
20
10
Circuit:
Contact
welding
detection
and Mis-
contacting
detection
circuit
Pick-up voltage
5
Max.
x
Min.
250V AC
4
3
9V DC
Drop-out voltage
Max.
x
2
Min.
Max.
x
1
Min.
0
0
0
0
3
3
No. of operations, ×104
No. of operations, ×104
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2013
ASCTB101E 201307-T
–3–
HE PV Type
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
CAD Data
Standard type
External dimensions
Schematic (Bottom view)
Single side stable type
PC board pattern (Bottom view)
38.0
1.496
33
1.299
24
.945
4.7
.185
1
4
8.4
.331
36.3
1.429
0.5
18.6
.732
6-2 dia. hole
6-.079 dia. hole
6
5
.020
4
32
1.260
.157
4.7
1.6
1.6
.063
0.8
.031
.063
.185
0.8
.031
General tolerance: 0.3 .012
Tolerance: 0.1 .004
High capacity type
External dimensions
Schematic (Bottom view)
Single side stable type
PC board pattern (Bottom view)
24
38.0
1.496
33
1.299
.945
6.5
.256
1
4
8.4
.331
36.3
1.429
18.6
.732
6
5
1.3
.051
0.5
.020
2-2 dia. hole
2-.079 dia. hole
4
.157
32
1.260
0.8
.031
6.3
.248
1.6
.063
0.8
.031
General tolerance: 0.3 .012
Tolerance: 0.1 .004
SAFETY STANDARDS
Certification body
Contact rating
48A 277V AC (at 85°C 185°F)
*60A 277V AC (general use, at 60°C 140°F, 10k cycle), in use at 60% of rated coil voltage
C-UL
48A 250V AC cosφ = 0.8 (at 85°C 185°F)
*72A 250V AC (cosφ = 0.8 at 85°C 185°F, 50 cycle)
*60A 250V AC (cosφ = 0.8 at 85°C 185°F, 10k cycle)
*50A 20V DC (0ms, at 85°C 185°F, 30k cycle)
High capacity type
VDE (VDE0435)
UL/CSA
Standard type
35A 277V AC (at 25°C 77°F)
35A 250V AC cosφ = 1 (at 80°C 176°F)
VDE (VDE0435)**
* Under development. Please contact us.
** Only 9V DC type is Certified by VDE
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2013
ASCTB101E 201307-T
–4–
HE PV Type
NOTES
ꢀ Usage, transport and storage
conditions
Temperature and humidity range for
usage, transport, and storage
ꢀ Certification
This relay is UL/C-UL certified.
48 A 277 V AC (High capacity type)
35 A 277 V AC (Standard type)
This relay is certified by VDE
48 A 250 V AC cosφ = 0.8
(High capacity type)
1) Temperature:
Humidity, %RH
–50 to +55°C –58 to +131°F
–50 to +85°C –58 to +185°F (When
applied coil hold voltage is 50% to 60% of
nominal coil voltage)
85
Tolerance range
(Avoid freezing (Avoid
when used at condensation
2) Humidity: 5 to 85% RH
35 A 250 V AC cosφ = 1
(Standard type)
temperatures
lower than
0°C 32°F)
when used at
temperatures
higher than
0°C 32°F)
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
3) Atmospheric pressure: 86 to 106 kPa
5
–50
–58
0
+32
55
+131
Temperature, °C °F
Humidity, %RH
85
Tolerance range
(Avoid freezing (Avoid
when used at condensation
temperatures
lower than
0°C 32°F)
when used at
temperatures
higher than
0°C 32°F)
5
–50
–58
0
+32
85
+185
Temperature, °C °F
∗ –50 to +85°C –58 to +185°F (When applied
coil hold voltage is 50% to 60% of nominal
coil voltage)
Panasonic Corporation Automation Controls Buisiness Division
industrial.panasonic.com/ac/e/
© Panasonic Corporation 2013
ASCTB101E 201307-T
–5–
相关型号:
HE1AN-Q-AC120V
Power/Signal Relay, SPST, Momentary, 2700mW (Coil), 30A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Panel Mount, ROHS COMPLIANT
PANASONIC
©2020 ICPDF网 联系我们和版权申明