Amplifier Built-in  
Convergent Reflective Photoelectric Sensor  
313  
EX-40 SERIES  
General terms and conditions............. F-3  
Glossary of terms / General precautions .....P.1549~ / P.1552~  
Selection guide............................. P.231~  
Korea’s S-mark............................. P.1602  
FIBER  
SENSORS  
Related Information  
LASER  
SENSORS  
PHOTOELECTRIC  
SENSORS  
Certified  
(Excluding 5 m cable length type)  
MICRO  
PHOTOELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS /  
SAFETY COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE SENSORS  
SENSOR  
OPTIONS  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
MEASUREMENT  
SENSORS  
panasonic.net/id/pidsx/global  
Timer  
STATIC  
CONTROL  
DEVICES  
LASER  
MARKERS  
Reliable object detection in limited area  
PLC  
HUMAN MACHINE  
INTERFACES  
Stable convergent distance sensing  
ENERGY  
MANAGEMENT  
SOLUTIONS  
The sensor does not detect even a  
specular object 100 mm 3.937 in, or  
more, away from the sensing surface.  
(with EX-43)  
EX-43: Correlation between material  
and sensing range  
Due to convergent  
distance sensing, the  
FA COMPONENTS  
Background  
color or material of  
the object has almost  
no effect. Further, the  
background also has  
very little effect, enabling  
stable sensing.  
100  
3.937  
MACHINE VISION  
SYSTEMS  
However, the specular  
background should be a plane  
surface, directly facing the  
sensor. A spherical or curved  
background may be detected.  
UV CURING  
SYSTEMS  
50  
1.969  
30  
1.181  
0
A
B
C
D
E
F
G
H
A
B
Aluminum-evaporated mirror  
D
E
F
G
H
White non-glossy paper  
White ceramic circuit board  
Cardboard  
Selection  
Guide  
Amplifier  
Built-in  
Stainless steel plate  
Aluminum plate  
C
Glass epoxy printed circuit board  
(Green masked surface)  
Black rubber sheet  
Black substrate  
Power Supply  
Built-in  
Amplifier-  
separated  
FUNCTIONS  
MOUNTING / SIZE  
Compact size (W10 × H30 × D18 mm W0.394 × H1.181 × D0.709 in)  
EX-43T  
EX-Z  
CX-400  
CY-100  
EX-10  
Variable OFF-delay timer  
The spot-beam type EX-43T  
is incorporated with an OFF-  
delay timer. The variable  
OFF-delay timer is useful  
for detecting a printed circuit  
board regardless of small  
holes, cutouts, or electronic  
parts on it.  
It can be installed in a limited space.  
VARIETIES  
EX-20  
Various applications  
EX-30  
EX-40  
Diffused beam type  
Spot-beam type  
CX-440  
EQ-30  
Sensing area  
Sensing point  
Time Chart  
EQ-500  
MQ-W  
Light  
Dark  
Sensing condition  
RX-LS200  
RX  
ON  
• Visible red spot beam allows  
easy targetting.  
• It is suitable for positioning  
because of its 0.05 mm 0.002  
in repeatability.  
Even in a limited sensing  
area, the sensor is not  
affected by small perforations  
or unevenness. It is suitable  
for presence detection.  
Output operation  
(Light-ON)  
T
OFF  
Timer period: T = 0.1 to 1 sec. approx.  
RT-610  
Convergent Reflective Photoelectric Sensor EX-40 SERIES  
314  
APPLICATIONS  
FIBER  
SENSORS  
LASER  
Positioning of a PCB  
Sensing parts in feeder  
Positioning of trays  
SENSORS  
PHOTO-  
ELECTRIC  
SENSORS  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
AREA  
SENSORS  
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
COMPONENTS  
PRESSURE /  
FLOW  
SENSORS  
INDUCTIVE  
PROXIMITY  
SENSORS  
PARTICULAR  
USE  
ORDER GUIDE  
SENSORS  
SENSOR  
OPTIONS  
Sensitivity  
adjuster  
Timer  
function  
Emitting  
element  
Type  
Appearance  
Sensing range (Note 1)  
Model No.  
Output  
SIMPLE  
WIRE-SAVING  
UNITS  
5 to 38 mm 0.197 to 1.496 in  
(Convergent point: 20 mm 0.787 in)  
WIRE-SAVING  
SYSTEMS  
EX-42  
Infrared  
LED  
MEASURE-  
MENT  
10 to 70 mm  
0.394 to 2.756 in  
(Convergent point: 40 mm 1.575 in)  
SENSORS  
EX-44  
NPN  
STATIC  
CONTROL  
DEVICES  
open-collector Incorporated  
transistor  
EX-43  
LASER  
MARKERS  
20 to 35 mm 0.787 to 1.378 in  
(Convergent point: 30 mm 1.181 in)  
Red LED  
PLC  
Incorporated  
EX-43T  
HUMAN  
MACHINE  
INTERFACES  
NOTE: Mounting bracket is not supplied with the sensor. Please select from the range of optional sensor mounting brackets  
ENERGY  
(two types).  
MANAGEMENT  
SOLUTIONS  
Note: The sensor does not detect even a specular background if it is separated by the distance specified below.  
FA  
EX-42...150 mm 5.906 in or more, EX-44...300 mm 11.811 in or more, EX-43 and EX-43T...100 mm 3.937 in or more  
COMPONENTS  
These are typical values. However, the specular background should be a plane surface, directly facing the sensor.  
A spherical or curved background may be detected.  
MACHINE  
VISION  
SYSTEMS  
UV  
5 m 16.404 ft cable length type  
CURING  
SYSTEMS  
5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available.  
When ordering this type, suffix “-C5” to the model No.  
(e.g.) 5 m 16.404 ft cable length type of EX-42 is “EX-42-C5”.  
Selection  
Guide  
OPTIONS  
Amplifier  
Built-in  
Sensor mounting bracket  
Power Supply  
Built-in  
Designation  
Model No.  
Description  
• MS-EX40-1  
• MS-EX40-2  
Amplifier-  
separated  
Rear mounting bracket  
Bottom mounting bracket  
Horizontal mounting type  
Vertical mounting type  
Horizontal mounting type  
Vertical mounting type  
MS-EX40-1  
MS-EX40-2  
MS-AJ1  
Sensor mounting  
bracket  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
Basic assembly  
Universal  
sensor  
mounting stand  
(Note)  
MS-AJ2  
Two M3 (length  
16 mm 0.630 in) screws  
with washers are  
attached.  
Two M3 (length 16 mm  
0.630 in) screws with  
washers are attached.  
MS-AJ1-A  
MS-AJ2-A  
Lateral arm assembly  
Note: Refer to p.953~ for the universal sensor mounting stand MS-AJ.  
Universal sensor mounting stand  
• MS-AJ1  
• MS-AJ1-A  
With the lateral arm, the  
sensor can sense from  
above a production line.  
• MS-AJ2  
• MS-AJ2-A  
Swivel:  
360° rotation  
Swivel:  
With the lateral arm, the  
sensor can sense from  
above a production line.  
Swivel:  
Swivel:  
360° rotation  
360° rotation  
360° rotation  
Height  
Forward / back  
Height  
45°  
45°  
45°  
45°  
Forward / back  
Height  
adjustment:  
150 mm  
5.906 in  
approx.  
Height  
adjustment:130 mm 5.118 in  
adjustment:  
150 mm  
5.906 in  
approx.  
adjustment:130 mm 5.118 in  
adjustment:  
150 mm  
5.906 in  
approx.  
adjustment:  
150 mm  
5.906 in  
approx.  
Elevation  
Elevation  
angle: 45°  
angle: 45°  
360°  
360  
°
rotation  
RT-610  
45°  
rotation  
Mounting hole for  
M6 screw  
45°  
Mounting hole for  
M6 screw  
Mounting hole for  
M6 screw  
45°  
Mounting hole for  
M6 screw  
Angle  
45°  
Angle  
adjustment: 45°  
adjustment: 45°  
Convergent Reflective Photoelectric Sensor EX-40SERIES  
315  
FIBER  
SPECIFICATIONS  
SENSORS  
LASER  
SENSORS  
Diffused beam type  
Type  
Spot-beam type  
PHOTO-  
ELECTRIC  
SENSORS  
Long sensing range  
With timer  
Item  
Model No.  
EX-42  
EX-44  
EX-43  
EX-43T  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
CE marking directive compliance  
EMC Directive, RoHS Directive  
AREA  
5 to 38 mm 0.197 to 1.496 in (Conv. point: 20 mm 0.787 in)  
with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
10 to 70 mm 0.394 to 2.756 in (Conv. point: 40 mm 1.575 in)  
with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
20 to 35 mm 0.787 to 1.378 in (Conv. point: 30 mm 1.181 in)  
with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
Sensing range  
SENSORS  
SAFETY LIGHT  
CURTAINS  
/
ø0.2 mm ø0.008 in copper wire  
(Setting distance: 20 mm 0.787 in)  
ø0.2 mm ø0.008 in copper wire  
(Setting distance: 40 mm 1.575 in)  
SAFETY  
Min. sensing object  
ø0.03 mm ø0.001 in gold wire (Setting distance: 30 mm 1.181 in)  
COMPONENTS  
PRESSURE /  
FLOW  
Hysteresis  
15 % or less of operation distance with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in) 10 % or less of operation distance with white non-glossy paper (50 × 50 mm 1.969 × 1.969 in)  
SENSORS  
Repeatability  
0.1 mm 0.004 in or less  
0.2 mm 0.008 in or less  
INDUCTIVE  
PROXIMITY  
SENSORS  
0.05 mm 0.002 in or less (Setting distance: 30 mm 1.181 in)  
(perpendicular to sensing axis) (Setting distance: 20 mm 0.787 in) (Setting distance: 40 mm 1.575 in)  
Supply voltage  
12 to 24 V DC ±10 % Ripple P-P 10 % or less  
35 mA or less  
PARTICULAR  
USE  
SENSORS  
Current consumption  
SENSOR  
OPTIONS  
NPN open-collector transistor  
• Maximum sink current: 100 mA  
Output  
• Applied voltage: 30 V DC or less (between output and 0 V)  
• Residual voltage: 1.5 V or less (at 100 mA sink current)  
0.4 V or less (at 16 mA sink current)  
SIMPLE  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
Utilization category  
Output operation  
DC-12 or DC-13  
Light-ON  
Incorporated  
MEASURE-  
MENT  
SENSORS  
Short-circuit protection  
Response time  
STATIC  
CONTROL  
DEVICES  
0.5 ms or less  
Operation indicator  
Stability indicator  
Red LED (lights up when the output is ON)  
Green LED (lights up under stable light received condition or stable dark condition)  
Continuously variable adjuster  
LASER  
MARKERS  
Sensitivity adjuster  
PLC  
Variable OFF-delay timer  
(0.1 to 1 sec. approx.) (Note 2)  
Timer function  
HUMAN  
MACHINE  
INTERFACES  
Pollution degree  
Protection  
3 (Industrial environment)  
ENERGY  
MANAGEMENT  
SOLUTIONS  
IP67 (IEC)  
Ambient temperature  
Ambient humidity  
Ambient illuminance  
Voltage withstandability  
Insulation resistance  
Vibration resistance  
Shock resistance  
Emitting element  
Material  
–25 to +55 °C –13 to +131 °F (No dew condensation or icing allowed), Storage: –30 to +70 °C –22 to +158 °F  
35 to 85 % RH, Storage: 35 to 85 % RH  
FA  
COMPONENTS  
MACHINE  
VISION  
Incandescent light: 3,000 ℓx or less at the light-receiving face  
SYSTEMS  
1,000 V AC for one min. between all supply terminals connected together and enclosure  
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure  
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude (20 G max.) in X, Y and Z directions for two hours each  
500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each  
Infrared LED (Peak emission wavelength: 880 nm 0.035 mil, modulated) Red LED (Peak emission wavelength: 680 nm 0.027 mil, modulated)  
Polyalylate  
UV  
CURING  
SYSTEMS  
Selection  
Guide  
Cable  
0.2 mm2 3-core cabtyre cable, 2 m 6.562 ft long  
Amplifier  
Built-in  
Cable extension  
Weight  
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.  
Net weight: 45 g approx., Gross weight: 70 g approx.  
Power Supply  
Built-in  
Amplifier-  
separated  
Accessory  
Adjusting screwdriver: 1 pc.  
Notes: 1) Where measurement conditions heve not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
2) The timer is always effective.  
I/O CIRCUIT AND WIRING DIAGRAMS  
I/O circuit diagram  
Wiring diagram  
Color code  
D
(Brown) +V  
Load  
Brown  
+
(Black) Output  
100 mA max.  
(Blue) 0 V  
12 to 24 V DC  
10 %  
Load  
Tr  
+
ZD  
Black  
Blue  
12 to 24 V DC  
1ꢀ %  
Internal circuit  
Users’ circuit  
Symbols … D : Reverse supply polarity protection diode  
ZD: Surge absorption zener diode  
RT-610  
Tr : NPN output transistor  
Convergent Reflective Photoelectric Sensor EX-40 SERIES  
316  
SENSING CHARACTERISTICS (TYPICAL)  
FIBER  
SENSORS  
LASER  
EX-42  
SENSORS  
Sensing field  
Correlation between sensing object size and sensing range  
PHOTO-  
ELECTRIC  
SENSORS  
As the sensing object size becomes smaller  
than the standard size (white non-glossy paper  
50 × 50 mm 1.969 × 1.969 in), the sensing  
range shortens, as shown in the left graph.  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
40  
40  
1.575  
1.575  
AREA  
SENSORS  
a × a mm a × a in  
For plotting the left graph, a sensor having  
a sensitivity such that it can just detect a 50  
× 50 mm 1.969 × 1.969 in white non-glossy  
paper at a distance of 38 mm 1.496 in has  
been used.  
SAFETY LIGHT  
White non-glossy paper  
CURTAINS  
SAFETY  
/
50 × 50 mm 1.969 × 1.969 in  
White non-glossy paper  
20  
20  
COMPONENTS  
0.787  
0.787  
L
PRESSURE /  
FLOW  
L
SENSORS  
Sensor  
Sensor  
0
INDUCTIVE  
PROXIMITY  
SENSORS  
0
0
20  
40  
1.575  
60  
80  
3.150  
4
2
2
4
0.787  
2.362  
0.157  
(Down) Left  
0.079  
0.079  
0.157  
PARTICULAR  
USE  
Center  
Operating point ℓ (mm in)  
Right (Up)  
White non-glossy paper  
side length a (mm in)  
SENSORS  
SENSOR  
OPTIONS  
Correlation between lightness and sensing range  
Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range  
SIMPLE  
The sensing region (typical) is  
The bars in the graph indicate  
the sensing range (typical)  
for the respective material.  
WIRE-SAVING  
UNITS  
represented by oblique lines  
in the left figure. However, the  
sensitivity should be set with  
enough margin because of  
slight variation in products.  
100  
40  
3.937  
1.575  
WIRE-SAVING  
SYSTEMS  
However, there is a slight  
variation in the sensing range  
depending on the product.  
Further, if there is a reflective  
object (conveyor, etc.) in the  
background of the sensing  
object, since it affects the  
sensing, separate it by more  
than twice the sensing range  
shown in the left graph.  
Sensing region  
MEASURE-  
MENT  
SENSORS  
50  
20  
1.969  
0.787  
STATIC  
CONTROL  
DEVICES  
20  
0.787  
LASER  
MARKERS  
0
0
N2  
N4  
N6  
N8  
Lightness shown on the  
left may differ slightly  
from the actual object  
condition.  
Dark  
Lightness  
Light  
PLC  
N1 N2 N3 N4 N5 N6 N7 N8 N9  
HUMAN  
MACHINE  
INTERFACES  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
EX-44  
COMPONENTS  
MACHINE  
VISION  
Sensing field  
Correlation between sensing object size and sensing range  
As the sensing object size becomes smaller  
SYSTEMS  
UV  
CURING  
SYSTEMS  
than the standard size (white non-glossy paper  
50 × 50 mm 1.969 × 1.969 in), the sensing  
range shortens, as shown in the left graph.  
100  
100  
3.937  
3.937  
a × a mm a × a in  
For plotting the left graph, the sensitivity has  
been set such  
that a 50 × 50 mm 1.969 × 1.969 in white  
non-glossy paper is just detectable at a  
distance of 70 mm 2.756 in.  
White non-glossy paper  
50  
1.969  
50  
50 × 50 mm 1.969 × 1.969 in  
White non-glossy paper  
Selection  
Guide  
1.969  
40  
L
1.575  
Amplifier  
Built-in  
L
Sensor  
Power Supply  
Built-in  
Sensor  
0
0
Amplifier-  
separated  
20  
40  
1.575  
60  
80  
3.150  
0
4
2
2
4
0.787  
2.362  
0.157  
(Down) Left  
0.079  
0.079  
0.157  
Center  
Operating point ℓ (mm in)  
Right (Up)  
White non-glossy paper  
side length a (mm in)  
EX-Z  
Correlation between lightness and sensing range  
Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
The sensing region (typical) is  
The bars in the graph indicate  
the sensing range (typical)  
for the respective material.  
However, there is a slight  
variation in the sensing range  
depending on the product.  
represented by oblique lines  
in the left figure. However, the  
sensitivity should be set with  
enough margin because of  
slight variation in products.  
100  
200  
3.937  
7.874  
Sensing region  
50  
Further, if there is a reflective  
object (conveyor, etc.) in the  
background of the sensing  
object, since it affects the  
sensing, separate it by more  
than twice the sensing range  
shown in the left graph, or  
adjust the sensitivity adjuster.  
100  
1.969  
The graph is drawn for the  
maximum sensitivity setting.  
3.937  
40  
1.575  
40  
1.575  
0
0
0
N2  
N4  
N6  
N8  
Dark  
Lightness  
Light  
Lightness shown on the left  
may differ slightly from the  
actual object condition.  
N1 N2 N3 N4 N5 N6 N7 N8 N9  
The graph is drawn for the  
maximum sensitivity setting.  
RT-610  
Convergent Reflective Photoelectric Sensor EX-40SERIES  
317  
FIBER  
SENSING CHARACTERISTICS (TYPICAL)  
SENSORS  
LASER  
SENSORS  
EX-43 EX-43T  
PHOTO-  
ELECTRIC  
SENSORS  
Sensing field  
Correlation between lightness and sensing range  
The sensing region (typical) is  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
represented by oblique lines  
in the left figure. However, the  
sensitivity should be set with  
enough margin because of  
slight variation in products.  
40  
40  
AREA  
1.575  
1.575  
SENSORS  
50 × 50 mm  
30  
30  
Sensing region  
SAFETY LIGHT  
1.969 × 1.969 in  
1.181  
1.181  
CURTAINS  
/
White non-glossy  
SAFETY  
paper  
COMPONENTS  
20  
20  
The graph is drawn for  
the maximum sensitivity  
setting. However, EX-43T  
does not incorporate the  
sensitivity adjuster.  
0.787  
PRESSURE /  
FLOW  
0.787  
L
SENSORS  
Sensor  
INDUCTIVE  
PROXIMITY  
SENSORS  
0
0
4
2
0
2
4
N2  
N4  
N6  
N8  
Lightness shown on the  
left may differ slightly  
from the actual object  
condition.  
PARTICULAR  
USE  
0.157  
(Down) Left  
0.079  
0.079  
0.157  
Dark  
Lightness  
Light  
Center  
Right (Up)  
SENSORS  
Operating point ℓ (mm in)  
N1 N2 N3 N4 N5 N6 N7 N8 N9  
SENSOR  
OPTIONS  
Correlation between material (50 × 50 mm 1.969 × 1.969 in) and sensing range  
SIMPLE  
WIRE-SAVING  
UNITS  
The bars in the graph indicate  
the sensing range (typical)  
for the respective material.  
However, there is a slight  
variation in the sensing range  
depending on the product.  
WIRE-SAVING  
SYSTEMS  
100  
3.937  
MEASURE-  
MENT  
SENSORS  
STATIC  
CONTROL  
DEVICES  
Further, if there is a reflective  
object (conveyor, etc.) in the  
background of the sensing  
object, since it affects the  
50  
1.969  
30  
LASER  
1.181  
MARKERS  
sensing, separate it by more  
than twice the sensing range  
0
PLC  
shown in the left graph, or  
adjust the sensitivity adjuster.  
HUMAN  
MACHINE  
INTERFACES  
The graph is drawn for  
the maximum sensitivity  
setting. However, EX-43T  
does not incorporate the  
sensitivity adjuster.  
ENERGY  
MANAGEMENT  
SOLUTIONS  
FA  
COMPONENTS  
MACHINE  
VISION  
SYSTEMS  
PRECAUTIONS FOR PROPER USE  
Refer to p.1552~ for general precautions.  
UV  
CURING  
SYSTEMS  
Timer function (Only for EX-43T)  
Never use this product as a sensing device  
• The variable OFF-delay timer prolongs the output for a  
certain period (0.1 to 1 sec. approx.).  
It is useful when the connected device has a slow  
response time or when small objects are sensed and the  
signal width is small.  
for personnel protection.  
• In case of using sensing devices for  
personnel protection, use products which  
meet laws and standards, such as OSHA,  
ANSI or IEC etc., for personnel protection  
applicable in each region or country.  
Selection  
Guide  
Amplifier  
Built-in  
Power Supply  
Built-in  
(The timer is always effective.)  
Amplifier-  
separated  
Mounting  
Adjusters  
EX-Z  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
• With the optional sensor mounting bracket, the tightening  
torque should be 0.5 N·m or less.  
Timer adjuster  
OFF-delay time becomes longer  
(
)
if it is turned clockwise.  
Stability indicator (Green)  
Lights up under stable light received  
condition or stable dark condition.  
Operation indicator (Red)  
Lights up when the output  
Sensor mounting bracket  
MS-EX40-1  
(Optional)  
(
)
(
)
is ON.  
Time chart  
M3 (length 16 mm 0.630 in) screw with washers  
Light  
Dark  
Sensing  
condition  
Others  
ON  
Output  
T
T
T
• Do not use during the initial transient time (50 ms) after  
the power supply is switched on.  
operation  
OFF  
RT-610  
Timer period: T = 0.1 to 1 sec. approx.  
Convergent Reflective Photoelectric Sensor EX-40 SERIES  
318  
DIMENSIONS (Unit: mm in)  
FIBER  
The CAD data can be downloaded from our website.  
SENSORS  
LASER  
SENSORS  
Sensor  
EX-42 EX-44 EX-43 EX-43T  
PHOTO-  
Stability indicator  
(Green)  
ELECTRIC  
SENSORS  
Sensitivity adjuster (Note)  
MICRO  
PHOTO-  
ELECTRIC  
SENSORS  
Operation indicator  
(Red)  
AREA  
SENSORS  
18  
0.709  
1
SAFETY LIGHT  
CURTAINS  
SAFETY  
/
10  
3
0.039  
Beam-  
receiving  
part  
0.394  
0.118  
COMPONENTS  
8
Center of  
sensing  
PRESSURE /  
FLOW  
0.315  
13.1081  
SENSORS  
01.7948  
INDUCTIVE  
PROXIMITY  
SENSORS  
Beam-  
emitting  
part  
12.5  
0.492  
6 0.236  
PARTICULAR  
USE  
SENSORS  
ø3.7 ø0.146 cable,  
2 m 6.562 ft long  
2-ø3.2 ø0.126 mounting holes  
SENSOR  
OPTIONS  
Note: EX-42 does not incorporate it.  
SIMPLE  
In EX-43T, it is the timer adjuster.  
WIRE-SAVING  
UNITS  
WIRE-SAVING  
SYSTEMS  
Sensor mounting bracket (Optional)  
MS-EX40-1  
MEASURE-  
MENT  
Assembly dimensions  
SENSORS  
1
0.5  
18  
STATIC  
0.020  
0.709  
CONTROL  
DEVICES  
14  
t 1.2  
0.551  
t 0.047  
8
LASER  
25 0.984  
0.315  
MARKERS  
3.5  
3.4  
14 0.551  
3.2  
6
0.138  
0.134  
(27.2)  
10°  
0.126  
0.236  
(1.071)  
PLC  
8
8.5  
25 0.984  
14  
01.5312  
0.315  
0.335  
3.5  
t 1.2  
0.551  
10°  
0.138  
6
10  
HUMAN  
t 0.047  
R19 R0.748  
R19 R0.748  
18  
0.236  
13.3578 01.7948  
MACHINE  
INTERFACES  
0.394  
0.709  
8.5  
8
0.315  
0.335  
Center of  
sensing  
ENERGY  
MANAGEMENT  
SOLUTIONS  
30  
1.181  
18  
19  
35  
6
0.709 0.748  
1.378  
3.2  
0.126  
0.236  
10°  
FA  
t 1.5  
2
COMPONENTS  
t 0.059  
6
MACHINE  
VISION  
0.236  
24 0.945  
19 0.748  
3.4 0.134  
SYSTEMS  
8 0.315  
10°  
Material: Stainless steel (SUS304)  
14  
0.551  
UV  
5 0.197  
CURING  
SYSTEMS  
Two M3 (length 16 mm 0.630 in) screws  
with washers are attached.  
2-M3 × 0.5 0.020  
Sensor mounting bracket (Optional)  
MS-EX40-2  
Assembly dimensions  
Selection  
Guide  
1
15  
Amplifier  
Built-in  
15  
0.591  
0.591  
Power Supply  
Built-in  
t 1.5  
Amplifier-  
separated  
t 0.059  
18  
0.5  
0.709  
0.020  
02.9584 01.7948  
20  
45  
R25 R0.984  
02.7087 13.4757  
EX-Z  
0.787  
(12.9)  
1.772  
R19 R0.748  
18.9  
01.7948  
(0.508)  
0.744  
3.5  
CX-400  
CY-100  
EX-10  
EX-20  
EX-30  
EX-40  
CX-440  
EQ-30  
EQ-500  
MQ-W  
RX-LS200  
RX  
10  
6.5  
0.138  
5
8
0.394  
1.5  
7°  
0.256  
0.197  
0.315  
3.2  
0.059  
7 0.276  
0.126  
4
0.157  
5 6.5  
2
7°  
7
12  
3.2  
0.197  
18.90.256  
0.079  
7.9  
0.276  
0.472  
0.126  
3.5  
21.5  
0.311  
2
13.4757  
0.846  
0.744  
45  
0.138  
13.1081  
1.772  
02.7087  
19  
0.748  
t 1.5  
t 0.059  
2400.7.94485  
19  
Center of sensing  
Material: Stainless steel (SUS304)  
5 0.197  
Two M3 (length 16 mm 0.630 in) screws with  
washers are attached.  
7°  
2-M3 × 0.5 0.020  
RT-610  

相关型号:

EX-43T

Convergent Reflective Photoelectric Sensor
PANASONIC

EX-4500

EXTIRUDED ALUMINUM BOX
ETC

EX-4501

EXTIRUDED ALUMINUM BOX
ETC

EX-4502

EXTIRUDED ALUMINUM BOX
ETC

EX-620

Evacuated Miniature Crystal Oscillator
VECTRON

EX-620-CAC-508A-20.0000MHZ

HCMOS Output Clock Oscillator, 20MHz Nom, HERMETIC SEALED, DIP-4
MICROSEMI

EX-620-CAC-508F-11.6800MHZ

HCMOS Output Clock Oscillator, 11.68MHz Nom, HERMETIC SEALED, MINIATURE, DIP-4
MICROSEMI

EX-620-CAC-508F-12.8000MHZ

HCMOS Output Clock Oscillator, 12.8MHz Nom, HERMETIC SEALED, MINIATURE, DIP-4
MICROSEMI

EX-620-CAC-508F-16.3840MHZ

HCMOS Output Clock Oscillator, 16.384MHz Nom, HERMETIC SEALED, MINIATURE, DIP-4
MICROSEMI

EX-620-CAD-758A-12.8000

Evacuated Miniature Crystal Oscillator
VECTRON

EX-620-CAD-758F-10.0000MHZ

HCMOS Output Clock Oscillator, 10MHz Nom, HERMETIC SEALED, MINIATURE, DIP-4
MICROSEMI

EX-620-CAD-758F-11.6800MHZ

HCMOS Output Clock Oscillator, 11.68MHz Nom, HERMETIC SEALED, MINIATURE, DIP-4
MICROSEMI