●Confirm from the confirmation window, shown in the figure below,
that the wires have been inserted to a position at which they are
visible.
INSTRUCTION MANUAL
Confirmation window
Connector
CN-14, CN-14H, CN-14H-2
MJEC-CN14H No.0054-49V
Thank you very much for parchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the
correct and optimum use of this product.
③
Insert the connector
in the guide of the
exclusive hook-up
CN-HP
Guide
Kindly keep this manual in a convenient place for quick reference.
CN-14H or
pliers
CN-HP
CN-14H-2
Do not plug in / pull out the connector more than 10 times,
since it can cause contact-failure. Furthemode, take care not
to apply any force to the terminal of the connector CN-14.
(optional) in the
direction shown in
the figure right. (Do
not mistake the
connector direction.)
1
OUTLINE
●This is a connector for connection to PM-□54(P) (connector type).
●The hook-up connector CN-14H and CN-14H-2 can be hooked-up
to the cable in a single operation, by using the exclusive hook-up
pliers CN-HP (optional).
④ Set the connec-
tor correctly.
2
●
SUITABLE CABLE
The cable suitable for the hook-up
connector CN-14H or CN-14H-2
is given in the table below.
Further, the wire insulation
material should be vinyl chloride
or soft polyethylene.
Cable diameter
Wire diameter
Conductor
cross-section area
Suitable cable
<Good>
⑤ Squeeze the pliers while
pushing in the wires so
that they do not come
out.
<Not good>
Model No.
CN-14H
CN-14H-2
Conductor cross-section area
0.08 to 0.2mm2 (AWG28 to AWG24) ø0.7 to ø1.2mm
0.18 to 0.22mm2 (AWG25 to AWG24)
1.2 to ø1.52mm
Wire diameter Rated current Rated voltage
Hook-up by squeezing
till the blades touch.
1A
50V DC
ø
3
CAUTIONS
●Make sure to use the exclusive hook-up pliers CN-HP to hook-up
the connectors CN-14H and CN-14H-2. Commercially available
pliers cannot be used for its hook-up.
●
●
Never reuse a hook-up connector. Its performance cannot be guaranteed.
When the connector is inserted into the PM-□54(P), insert it straight till the
hook of the connector si fitted to the hook of the sensor. In order to pull the
connector out, hold the connector body and then apply a force to the extent
that the hook of the connector comes off from the hook of t he sensor.
●Always connect or disconnect the cable attached connector by
holding the connector. Never pull the cable, since it may cause a
cable break.
4
SOLDERING (CN-14)
●If soldering is done directly on the terminals of the connector
CN-14 strictly adhere to the conditions given below.
Soldering temperature
Soldering time
260°C or less
3 sec. or less
1.5mm
0V
2
1
+V
Soldering position
Refer to the figure right
Soldering
position
5
HOOK-UP PROCEDURE (CN-14H, CN-14H-2)
① Strip the cable sheath.
● Do not strip the wire insulation.
Wire
Sheath
15mm or more
②
Insert the wires into the wire insertion
holes of the connector till the wire tips
touch the hole ends.
● Arrangement of CN-14H and CN-14H-2.
+V:+V
1:Output 1 (Light-ON)
Power
supply
+V
1
2
0V
(Note)
2:Output 1 (Dark-ON)
0V:0V
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
Note: Wire terminal Nos. 1 and 2 as per requirement.