16 A Type Power Rocker
Switches with a 3 mm
Contact gap Secured
AJ8 (J8)
SWITCHES
FEATURES
• Power rocker switches for safety requirements.
• High inrush current resistance is ideal for Power switch of
office automation equipment.
• A broad product line (TV-8 rating type added to lineup)
Standard actuator
Wide actuator
ORDERING INFORMATION
AJ 8
F
Actuator indication
0: No indication
Number of poles and Operation
1: 1-pole, single throw (ON-OFF)
2: 2-pole, single throw (ON-OFF)
Flange color
F: Cadmium-free product
Nil: Black (standard color)
(Custom ordered color:
W: White, H: Light gray) Note 1)
1:
2:
indication (Indication on top)
indication (Indication on top)
Actuator
Terminal shape
Actuator color
Insulation guard
Nil: Standard actuator
W: Wide actuator
0: .250 Quick-connect terminal
1: Soldering terminal
2: PC board terminal
W: White B: Black R: Red
Nil: Short guard type
T: Long guard type (.250 Quick-connect terminal and
soldering terminal of standard actuator only)
3: PC board right angle terminal (for standard actuator only)
4: PC board left angle terminal (for standard actuator only)
Notes: 1. Please consult us for details concerning different flange colors.
2. “ ” is engraved on all flanges.
3. The color of indication on the actuator:
• White actuator: black
• Others: white
4. They come with a stamp indicating safety standards.
■ TV rating type
AJ 8 2
B TV F
Number of poles and Operation
2: 2-pole, single throw (ON-OFF) 0: .250 Quick-connect
Terminal shape
Actuator indication
0: No indication
Actuator color
B: Black
Rating
TV: TV rating
F: Cadmium-free product
terminal
1: Soldering terminal
2:
indication
ビパヒペ
AECTB4E ビパヒペパペ
ビパヒペハパペ
ー 1 ー
AJ8 (J8) Switches
PRODUCT TYPES
■ Standard actuator type
1) Without indication on actuators
Part No.
Without indication
AJ8100∗F
AJ8200∗F
AJ8110∗F
AJ8210∗F
AJ8120∗F
AJ8220∗F
AJ8130∗F
AJ8230∗F
AJ8140∗F
AJ8240∗F
Terminal shape
.250 Quick-connect terminal
Soldering terminal
Poles
Operating types
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
PC board terminal
ON-OFF
PC board right angle terminal
PC board left angle terminal
(Standard flange color is black.)
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type. When ordering, please add a “T” before the “F” at the end of the part
number.
3. The color of indication on the actuator:
• For white actuator: black
• For others: white
4. They come with a stamp indicating safety standards.
5. Note that the position of the I mark on the flange is used as a reference for left angle and right angle terminals as shown in the diagram below.
I mark
I mark
Right angle terminal
Left angle terminal
2) With indication on actuators
Part No.
Terminal shape
Poles
Operating types
With
indication
With
indication
AJ8102∗F
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
AJ8101∗F
.250 Quick-connect terminal
Soldering terminal
AJ8201∗F
AJ8111∗F
AJ8211∗F
AJ8121∗F
AJ8221∗F
AJ8131∗F
AJ8231∗F
AJ8141∗F
AJ8241∗F
AJ8202∗F
AJ8112∗F
AJ8212∗F
AJ8122∗F
AJ8222∗F
AJ8132∗F
AJ8232∗F
AJ8142∗F
AJ8242∗F
PC board terminal
ON-OFF
PC board right angle terminal
PC board left angle terminal
(Standard flange color is black.)
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.
2. Long guard type is available for .250 Quick-connect terminal and soldering terminal type. When ordering, please add a “T” before the “F” at the end of the part
number.
3. The color of indication on the actuator:
• For white actuator: black
• For others: white
4. They come with a stamp indicating safety standards.
5. Note that the position of the I mark on the flange is used as a reference for left angle and right angle terminals as shown in the diagram below.
I mark
I mark
Right angle terminal
Left angle terminal
ビパヒペ
AECTB4E ビパヒペパペ
ー 2 ー
AJ8 (J8) Switches
■ Wide actuator type
1) Without indication on actuators
Part No.
Terminal shape
.250 Quick-connect terminal
Soldering terminal
Poles
Operating types
ON-OFF
Without indication
AJ8W100∗F
AJ8W200∗F
AJ8W110∗F
AJ8W210∗F
AJ8W120∗F
AJ8W220∗F
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
PC board terminal
2) With indication on actuators
Part No.
Terminal shape
Poles
Operating types
ON-OFF
With
indication
With
indication
1-pole
2-pole
1-pole
2-pole
1-pole
2-pole
AJ8W101∗F
AJ8W102∗F
.250 Quick-connect terminal
Soldering terminal
AJ8W201∗F
AJ8W111∗F
AJ8W211∗F
AJ8W121∗F
AJ8W221∗F
AJ8W202∗F
AJ8W112∗F
AJ8W212∗F
AJ8W122∗F
AJ8W222∗F
PC board terminal
(Standard flange color is black.)
Notes: 1. A letter indicating the actuator color is entered in place of asterisk. (W: White, B: Black, R: Red)
For other flange colors type, black is the standard. For requests of other flange color, please refer to ORDERING INFORMATION.
2. The color of indication on the actuator:
• For white actuator: black
• For others: white
3. They come with a stamp indicating safety standards.
■ TV rating type
Part No.
Terminal shape
.250 Quick-connect terminal
Soldering terminal
Poles
Operating types
ON-OFF
Without indication
AJ8200BTVF
—
With
indication
—
AJ8202BTVF
—
2-pole
AJ8210BTVF
—
AJ8212BTVF
SPECIFICATIONS
■ Contact rating
Resistive load
(Power factor = 1)
Motor load* (EN61058-1)
(Power factor = 0.6)
Voltage
Inrush load
250V AC
16A
4A
160A (8.3ms)
Note: * The motor load is in accordance with EN61058-1. Inrush current can be switched up to the value of 6 times the indicated rating.
■ TV rating
Resistive load
Motor load (EN61058-1)
Capacitor load (EN61058-1)
Lamp load (UL61058-1)
Expected electrical life
(at 7 cpm)
Contact voltage
(Power factor = 1)
(Power factor = 0.6)
(Inrush load)
—
(TV-8)
8/117A
—
120V AC
250V AC
—
—
Min. 2.5 × 104
Min. 104
16A
4A
160A (8.3ms)
■ Characteristics
Item
Specifications
Mechanical
Electrical (at rated load)*
Min. 5 × 104 (at 20 cpm.)
Min. 104 (at 7 cpm.)
Expected life
Insulation resistance
Dielectric strength
Contact resistance
Min. 100 MΩ (at 500V DC measured by insulation resistive meter) Between terminals
Initial, 2,000 Vrms (detection current: 10 mA) Between terminals
Initial, Max. 100mΩ (by voltage drop at 1A, 2 to 4V DC)
Temperature rise (at terminal section)
Vibration resistance
Max. 30°C at 6 × 103 ope. or less (UL61058-1), Max. 55°C from 6 × 103 ope. to 104 (EN61058-1)
10 to 55 Hz at double amplitude of 1.5mm (Contact opening Max. 1 msec.)
Shock resistance
Min. 980m/s2
Actuator strength
40 N for 1 minute (operating direction)
Terminal strength (.250 Quick-connect terminal)
Ambient temperature
100 N for 1 minute or more (Pull & push direction)
–25°C to +85°C (no freezing and condensing)
Flame retardancy
UL94V-0
Tracking resistance
Min. 175
1-pole
2-pole
2.45 1.47N
4.5 2.5N
AgSnO2 alloy
Operating force
(reference characteristics)
Contact material
Note: Test conditions and judgment are complying with JIS C 6571, EN61058-1 and UL61058-1.
* Except TV rating type
ビパヒペ
AECTB4E ビパヒペパペ
ー 3 ー
AJ8 (J8) Switches
DIMENSIONS
(Unit: mm) General tolerance: 0.5
Diagram of recommended
CAD Data The CAD data of the products with a “CAD Data” mark can be downloaded from our Website.
■ .250 Quick-connect terminal/Short guard type
External dimensions
Long guard type
.250 Quick-connect terminal
CAD Data
panel mounting holes
X
ON
OFF
2-pole
1-pole
12.9+0.1
0
15
12.8
10
30
11
32° 4
7.7
16
ON
OFF
2
19.5
4.4
10.6
Panel thickness
0.75 to less than 1.25
X
1.75 dia.
0
28.2−0.1
0.8
6.35
4.375
0
15
28
8.75
12.5
1.25 or more to less than 2
2 or more to 3
28.4−0.1
0
28.8−0.1
■ Soldering terminal
External dimensions
Long guard type
Soldering terminal
Diagram of recommended
panel mounting holes
CAD Data
X
ON
OFF
2-pole
1-pole
12.9+0.1
0
15
12.8
10
30
32° 4
11
7.7
16
ON
OFF
2
19.5
10.6
Panel thickness
X
0.8
0
3.5
2.5
0.75 to less than 1.25
1.25 or more to less than 2
2 or more to 3
28.2−0.1
4.375
8.75
12.5
0
15
28
28.4−0.1
0
28.8−0.1
■ PC board terminal
External dimensions
PC board pattern
Diagram of recommended
panel mounting holes
CAD Data
2-pole
1-pole
0.1
15
3
X
0.2
0.1
0.1
1.2
15
3
0.2
0.1
1.2
0.1
12.9+0.1
8.75
0
0.1
4.375
2-pole
1-pole
15
12.8
10
30
32° 4
7.7
ON
OFF
2
16
19.5
(7.5)
Panel thickness
X
0
4
0.75 to less than 1.25
28.2−0.1
2
4.375
0.8
0
1.25 or more to less than 2
2 or more to 3
28.4−0.1
15
28
8.75
12.5
0
28.8−0.1
ビパヒペ
AECTB4E ビパヒペパペ
ー 4 ー
AJ8 (J8) Switches
■ PC board right angle terminal
External dimensions
PC board pattern
Diagram of recommended
panel mounting holes
CAD Data
2-pole
1-pole
0.1
15
3
X
0.2
0.1
0.1
1.2
8
15
3
12.9+0.1
0.2
0.1
0
0.3
1.2
17.5
0.1
0.1
4.375
0.3
Terminal side
21.0
2-pole
1-pole
15
12.8
10
30
32° 4
7.7
16
ON
OFF
2
19.5
2
Panel thickness
X
0
0.75 to less than 1.25
28.2−0.1
0.8
0
8
1.25 or more to less than 2
2 or more to 3
28.4−0.1
0
28.8−0.1
28
4
12.5
Note: Left angle terminal type is also available.
■ Wide actuator type
External dimensions
Diagram of recommended
panel mounting holes
CAD Data
22.0+0.1
0
X
2-pole
1-pole
25
21.8
19
32
32° 4
7.7
ON
OFF
2
16
Panel thickness
1 to less than 1.8
1.8 or more to 2.3
X
19.5
0
30.0−0.1
0
30.7−0.1
4.4
10.6
Note: Dimensions for the terminals of soldering
1.75 dia.
0.8
terminal type and PC board terminal type are
the same as those of standard actuator type.
6.35
8.75
21
4.375
15
29.4
■ Terminal circuit diagram (common)
Terminal number marking
Terminal circuit diagram
Terminal shape
1-pole
2-pole
PC board right angle terminal
(3)
(1)
(4)
(2)
(3)
(1)
(4)
(2)
250 Quick-connect terminal
Soldering terminal
PC board terminal
PC board left angle terminal
ビパヒペ
AECTB4E ビパヒペパペ
ー 5 ー
AJ8 (J8) Switches
CAUTIONS FOR USE
■ Switch mounting
Avoid touching the switch with soldering
iron.
■ Resistance to chemicals
To clean the switch unit, use a neutral
detergent diluted with water.
Do not use acidic or alkaline solvents as
they may damage the switch.
Furthermore, be careful not to get any of
the detergent solution inside of the switch
while cleaning it.
Mount the switch with the hole cutting
dimensions shown in the dimensions.
Please contact us if you are considering
using a panel of other than the
recommended size and shape.
■ Regarding fastening lead wires to
terminals
Soldering position
When wrapping or soldering a wire
around a terminal, do so in the shaded
area indicated in the diagram at left.
Contact terminal and common terminal
1) When connecting the tab terminals,
use a .250 Quick-connect and insert the
terminals straight in. If they are skewed,
the terminals will require excessive
insertion force.
In addition, there is some variation in the
insertion force required for different
receptacles from different manufacturers,
so confirm how much force is needed
under actual conditions.
Do not solder wires onto tab terminals.
2) With manual soldering: Complete the
soldering connection work within 3
seconds with the tip of the soldering iron
at a temperature of 420°C or lower, and
take care not to apply any force to the
terminal area.
■ Environment
Refer to the diagram above, “soldering
position,” for details on the position where
a wire should be soldered to a terminal.
When soldering PC board terminals,
keep soldering time to within 5 seconds
at 270°C soldering bath or within 3
seconds at 350°C soldering bath.
3) The terminals should be connected in
such a way that they are not under
constant stress from the connecting
wires.
Avoid using and storing these switches in
a location where they will be exposed to
corrosive gases, silicon, or high dust
levels, all of which can have an adverse
effect on the contacts.
■ Take care not to drop the product as
it may impair perfomance.
4) Terminal material is copper alloy which
may discolor due to finger’s oil or after a
long time. But that discoloration does not
effect actual performance.
INTRODUCTION TO 4P CONNECTORS FOR THE AJ8 (J8) SWITCH
(produced by Nippon Tanshi Co., Ltd)
Suitable switches: AJ8 (J8) switch, .250 Quick-connect terminal
(Note: Terminal guard long type switches are not suitable for this connector.)
• Housing
Product number: N1620-4Ⅺ04
Connectors for
AJ8 (J8) switch
• Receptacle
Product number: 17168-2 (post-plated product for fine wires)
17168-M2 (material plated product for fine wires)
172131-M2 (for thick wires)
• If you have any questions, please directly contact:
Nippon Tanshi Co., Ltd.
Note: This connector for AJ8 (J8) switches is not
available from Panasonic.
ビパヒペ
AECTB4E ビパヒペパペ
ー 6 ー
TechnicalTerminology & Cautions for Use
(Operation Switches)
TECHNICAL TERMINOLOGY
■ Rated values
■ Shock resistance
Values indicating the characteristics and performance guarantee
standards of the switches. The rated current and rated voltage,
for instance, assume specific conditions.
Max. shock value where a closed contact does not open for
longer than a specified time due to shocks during use of the
switches.
■ Electrical life
■ Allowable switching frequency
The service life when the rated load is connected to the contact
This is the maximum switching frequency required to reach the
and switching operations are performed.
end of mechanical life (or electrical life).
■ Mechanical life
■ Temperature rise value
The service life when operated at a preset operating frequency
without passing electricity through the contacts.
This is the maximum temperature rise value that heats the
terminal portion when the rated current is flowing through the
contacts.
■ Dielectric strength
Threshold limit value that a high voltage can be applied to a
predetermined measuring location for one minute without
causing damage to the insulation.
■ Actuator strength
When applying a static load for a certain period on the actuator
in the operation direction, this is the maximum load it can
withstand before the switch loses functionality.
■ Insulation resistance
This is the resistance value at the same place the dielectric
■ Terminal strength
strength is measured.
When applying a static load for a certain period (in all directions
if not stipulated) on a terminal, this is the maximum load it can
withstand before the terminal loses functionality (except when
the terminal is deformed).
■ Contact resistance
This indicates the electrical resistance at the contact part.
Generally, this resistance includes the conductor resistance of
the spring and terminal portions.
■ Vibration resistance
Vibration range where a closed contact does not open for longer
than a specified time due to vibrations during use of the snap-
action switches.
AECTB38E 201811-T
ー 7 ー
Technical Terminology & Cautions for Use
TYPES OF LOAD
■ Resistance load
■ Motor load
Resistance load is a power factor of 1 (cosφ = 1) where the load
is only for the resistance portion. The displayed switch rating
indicates the current capacity when using AC current.
Contacts may adhere due to the starting current at the start of
motor operation which is three to eight times the steady-state
current. Although it differs depending on the motor, since a
current flows that is several times that of the nominal current,
please select a switch taking into consideration the values in the
table below. To make the motor rotate in reverse, use an ON-
OFF-ON switch and take measures to prevent a multiplier
current (starting current + reverse current) from flowing.
■ DC load
Differing from AC, since the direction of current is fixed for DC,
the continuous arc time lengthens when the same voltage is
applied.
Motor type
Type
Starting current
■ Incandescent lamp load
Three-phase
induction motor
Approx. 5 to 8 times current listed on
nameplate
Squirrel-cage
Since an inrush current of 10 to 15 times the rated current flows
for an instant when the switch is turned on for the lamp,
adhesion of the contacts may occur. Therefore, please take into
consideration this transient current when selecting a switch.
Approx. 6 times current listed on
nameplate
Split-phase-start
Capacitor-start
Repulsion-start
Single-phase
induction motor
Approx. 4 to 5 times current listed on
nameplate
Approx. 3 times current listed on
nameplate
■ Induction load
Since arc generation due to reverse voltage can cause contact
failure to occur when there is an induction load (in relays,
solenoids and buzzers, etc.), we recommend you insert a
suitable spark quenching circuit (see figure below).
A current that is approximately two times that of the starting
current will flow when reverse rotation is caused during
operation. Also, when using for a load that will cause transient
phenomena such as when operating the motor in reverse
rotation or switching the poles, an arc short (circuit short) may
occur due to the time lag between poles when switching. Please
be careful.
Circuit example
Notes
Switch contact
(1) r = more than 10 Ω
(2) In an AC circuit,
Example of 1-pole motor reverse rotation circuit
r
c
R
R
R
impedance of R is to be slightly smaller
than impedance of r and c.
Power
supply
M
M
Switch contact
Power
supply
Can be used for both AC and DC circuits.
r = R
C: 0.1 μF
r
c
Good wiring
Bad wiring
Example of single-phase induction motor
(capacitor) strong-weak switching circuit
Switch contact
diode
Strong
Strong
Weak
Strong
M
For DC circuits only.
Weak
M
Weak
Strong
Power
supply
Switch contact
Good wiring
Bad wiring
Example of three-phase motor
ZNR
Varistor
Can be used for both AC and DC circuits.
reverse rotation circuit
Power
supply
M
Power
supply
M
Good wiring
Bad wiring
■ Capacitor load
In the case of mercury lamps, florescent lamps and the
capacitor loads of capacitor circuits, since an extremely large
inrush current flows when the switch is turned on, please
measure that transient value with the actual load and then either
use the product keeping within the range of the rated current or
after verifying the actual load.
AECTB38E 201811-T
ー 8 ー
Technical Terminology & Cautions for Use
CAUTIONS FOR USE
■ Environment of use
■ Wiring
1) Please consult us when using under the following conditions:
• Environments where hydrogen sulfide or other corrosive gases
are present.
1) When using a PC board terminal switch as soldering
terminals, use thin lead wires and be sure to wind them on the
terminals before soldering.
• Environments where gasoline, thinner or other flammable,
explosive gases are present.
• Dusty environments (for non-seal type snap action switches).
• Use in environments not in the prescribed temperature or
humidity range.
2) Cautions when soldering
Perform soldering quickly in accordance with the specified
conditions. Be careful not to let flux flow into the product. When
no instruction is specified, use a soldering iron with a tip
temperature of 350°C or lower and complete soldering within
five seconds. Do not pull on the lead wires immediately after
soldering. Wait some time before verifying.
• Places with low air pressure.
2) Unless specified the product will not be constructed to
withstand water, oil or explosions. Please inquire if you intend to
use the product in special applications.
■ Others
■ Usage, storage, and transport conditions
1) During usage, storage, or transportation, avoid locations
subject to direct sunlight and maintain normal temperature,
humidity, and pressure conditions.
2) The allowable specifications for environments suitable for
usage, storage, and transportation are given below.
(1) Temperature: The allowable temperature range differs for
each switch, so refer to the switch’s individual specifications.
(2) Humidity: 5 to 85% R.H.
1) Failure modes of switches include short-circuiting, open-
circuiting and temperature rises. If this switch is to be used in
equipment where safety is a prime consideration, examine the
possible effects of these failures on the equipment concerned,
and ensure safety by providing protection circuits or protection
devices. In terms of the systems involved, make provision for
redundancy in the design and take steps to achieve safety
design.
2) The ambient operating temperature (and humidity) range
quoted is the range in which the switch can be operated on a
continuous basis: it does not mean that using the switch within
the rating guarantees the durability performance and
environment withstanding performance of the switch. For details
on the performance guarantee, check the specifications of each
product concerned.
(3) Pressure: 86 to 106 kPa
The humidity range varies with the temperature. Use within the
range indicated in the graph below.
(The allowable temperature depends on the switch.)
Humidity, %R.H.
3) Even if 2-pole, 3-pole or 4-pole switches are used as single-
pole switches in order to increase contact reliability, please keep
the maximum current no higher than the rated value.
4) If there is the possibility of a short between poles, please use
an in-phase circuit as shown below or provide a spare pole.
85
Tolerance range
(Avoid freezing when
used at temperatures
lower than 0°C 32°F)
(Avoid
condensation when
used at temperatures
higher than 0°C 32°F)
Bad example
Load 1
5
–40
0
+85
–40
+32
+185
Load 2
Temperature, °C °F
Heteropolar circuit
• Condensation will occur inside the switch if there is a sudden
change in ambient temperature when used in an atmosphere of
high temperature and high humidity. This is particularly likely to
happen when being transported by ship, so please be careful of
the atmosphere when shipping. Condensation is the
phenomenon whereby steam condenses to cause water
droplets that adhere to the switch when an atmosphere of high
temperature and humidity rapidly changes from a high to low
temperature or when the switch is quickly moved from a low
humidity location to one of high temperature and humidity.
Please be careful because condensation can cause adverse
conditions such as deterioration of insulation, coil cutoff, and
rust.
Good example (1)
Load 1
Load 2
In-phase circuit
Good example (2)
Load 1
Spare pole
Load 2
• Condensation or other moisture may freeze on the switch when
the temperatures is lower than 0°C 32°F. This causes problems
such as sticking of movable parts or operational time lags.
• The plastic becomes brittle if the switch is exposed to a low
temperature, low humidity environment for long periods of time.
• Storage for extended periods of time (including transportation
periods) at high temperatures or high humidity levels or in
atmospheres with organic gases or sulfide gases may cause a
sulfide film or oxide film to form on the surfaces of the contacts
and/or it may interfere with the functions. Check out the
atmosphere in which the units are to be stored and transported.
• In terms of the packing format used, make every effort to keep
the effects of moisture, organic gases and sulfide gases to the
absolute minimum.
5) Be careful not to drop the product as this may cause loss of
functionality.
6) Do not apply an unreasonable vertical force against the
direction of operation of the product.
7) Use your hand to operate the actuator.
(Operation using a tool such as a screwdriver or hammer can
cause breakdown.)
AECTB38E 201811-T
ー 9 ー
Please contact ..........
Electromechanical Control Business Division
1006, Oaza Kadoma, Kadoma-shi, Osaka 571-8506, Japan
industral.panasonic.com/ac/e/
©Panasonic Corporation 2019
Specifications are subject to change without notice.
AECTB4E 201909
相关型号:
AJ8132L
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8132R
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8132W
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8132Y
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8132Z
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8140B
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8140BF
Rocker Switch, SPST, Latched, Solder Terminal, Standard Rocker Type Actuator, Through Hole-right Angle, ROHS COMPLIANT
PANASONIC
AJ8140G
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8140H
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
AJ8140L
Rocker Switch, SPST, Off-on, 2 PCB Hole Cnt, Solder Terminal, Rocker Actuator, Through Hole-right Angle
PANASONIC
©2020 ICPDF网 联系我们和版权申明