Compact size 2 Form A and
2 Form A 1 Form B 35A power
relays for energy management
and industrial equipment
HE-S RELAYS
TYPICAL APPLICATIONS
w
Ne
• Photovoltaic power generation systems (Solar inverter)
• Uninterruptible Power Supplies (UPS)
• Inverter
• Office air conditioner
• Industrial equipment
RoHS compliant
Protective construction: Flux-resistant type
FEATURES
1. High-capacity and long life 35A 277V AC 5×104 (long life
7. Contact gap (initial)
type)
• Form A contact: Min. 3.2 mm .126 inch/each contact
• Form B contact: Min. 0.7 mm .028 inch
Min. 0.5 mm .020 inch (When Form A contact
welded)
2. Electrical life (resistive load)
Form A contact
Standard type
Long life type
35A 277V AC
30A 220V AC
20A 277V AC
3×104
—
5×104
1×105
2×105
8. Mirror contact mechanisms (Compliant with EN60947-4-1
mirror contact)
1×105
3. Compact size and low operating power
W: 30 × L: 36 × H: 40 mm W: 1.181 × L: 1.417 × H: 1.575 inch
Operating power: 1,880 mW (holding power: 170 mW)
Detection of main contact welding makes it possible to
construct a safety circuit.
• Designed so that Form A contact and Form B contact will
4. Reduced coil holding voltage contributes to saving
energy of equipment
The coil holding voltage can be reduced up to 30%V of the
nominal coil voltage. This equals to operating power of
approximately 170 mW, which contributes equipment energy
savings.
not close at the same time.
• When Form A contact welded, Form B contact gap of at
least 0.5 mm .020 inch is maintained.
* Form B contact, when used to monitor the condition of Form A contact, can be
used exclusively as an auxiliary contact.
When Form A
contact welded
Normal operation
Non-excitation Excitation
Condi-
tions
* Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil
voltage.
Non-excitation
5. Contact gap: 3.2 mm .126 inch (VDE0126 compliant)
Compliant with European photovoltaic standard VDE0126
Compliant with EN61810-1 2.5 kV surge breakdown voltage
(between contacts)
Form A
contact
Form B
contact
Form A
contact
Form B
contact
Form A
contact
Form B
contact
Mirror
contact
mecha-
nisms
Welding
6. Insulation distance (initial)
• Between Form A contact and coil: Min. 11.0 mm .433 inch
(Clearance/Creepage)
• Between Form B contact and coil: Min. 3.2 mm .126 inch
(Clearance/Creepage)
• Between Form A contact sets: Min. 8.2 mm .323 inch
(Clearance/Creepage)
• Between Form A contact and Form B contact: Min. 12.8 mm
.504 inch (Clearance/Creepage)
ASCTB360E 201604-T
–1–
HE-S (AHES3, 4)
ORDERING INFORMATION
AHES
9
Contact arrangement / Operating function
3: 2 Form A Single side stable type
4: 2 Form A 1 Form B Single side stable type
Contact specifications
1: Standard type
2: Long life type
Terminals form
9: PC board terminal type
Nominal coil voltage (DC)
Part No.
0 1 2 3 5
Nominal coil voltage (V)
6 12 24 48 9
Note: Certified by UL/C-UL and VDE
TYPES
Part No.
Contact arrangement
Nominal coil voltage
Standard type
AHES3190
AHES3195
AHES3191
AHES3192
AHES3193
AHES4190
AHES4195
AHES4191
AHES4192
AHES4193
Long life type
AHES3290
AHES3295
AHES3291
AHES3292
AHES3293
AHES4290
AHES4295
AHES4291
AHES4292
AHES4293
6V DC
9V DC
2 Form A
12V DC
24V DC
48V DC
6V DC
9V DC
2 Form A 1 Form B
12V DC
24V DC
48V DC
Standard packing: Carton: 25 pcs.; Case: 100 pcs.
RATING
1. Coil data
Pick-up voltage
Drop-out voltage
(at 20°C 68°F)
(Initial)
Nominal operating
current
[ 10%] (at 20°C 68°F)
Nominal operating
power
(at 20°C 68°F)
Nominal coil
(at 20°C 68°F)
voltage
Coil resistance
[ 10%] (at 20°C 68°F)
Max. applied voltage
(at 55°C 131°F)
(Initial)
6V DC
9V DC
313mA
209mA
157mA
78mA
19.1Ω
43.1Ω
76.6Ω
306.4Ω
1,225.5Ω
110%V of nominal
coil voltage
75%V or less of
nominal voltage
5%V or more of
nominal voltage
ON: 1,880mW
12V DC
Holding: 170mW*1
150%V of nominal
coil voltage*2
24V DC
48V DC
39mA
Notes: *1. With 30%V coil holding voltage
*2. With no more than 24 hours per time with non-consecutive voltage application time.
ASCTB360E 201604-T
–2–
HE-S (AHES3, 4)
2. Specifications
Specifications
Characteristics
Item
Standard type
Long life type
Arrangement
2 Form A, 2 Form A 1 Form B
2 Form A, 2 Form A 1 Form B
Max. 100mΩ (By voltage drop 6V DC 1A),
Contact resistance (Initial)
Form A
contact
Max. 3mΩ (By voltage drop 6V DC 20A, Reference value)
Contact
Contact material
AgSnO2 type
Max. 100mΩ (By voltage drop 6V DC 1A)
Au flashed AgNi type
Contact resistance (Initial)
Contact material
Form B
contact*6
Nominal switching capacity
(Resistive load)
35A 277V AC
480V AC, 110V DC
9,695VA
Max. switching voltage
Form A
contact
Contact carring power
(Resistive load)
Max. switching current
35A
Min. switching capacity
(Reference value)*1
100mA 5V DC
Nominal switching capacity
(Resistive load)
1A 277V AC, 1A 30V DC
277V AC, 30V DC
277VA
Rating
Max. switching voltage
Form B
Contact carring power
(Resistive load)
contact*6
Max. switching current
1A
Min. switching capacity
(Reference value)*1
10mA 5V DC
1,880mW (after applying min.100ms coil nominal voltage)
170mW (30%V of coil holding voltage)
Nominal operating power
Insulation resistance (Initial)
Min. 1,000MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.
Max. 1,000A 1 ms, 3 times (Reference value)
Short current (A contact, Initial)
Between open Form A contacts
2,000 Vrms for 1 min. (Detection current: 10mA)
Between Form A contact and coil
Between Form A contact sets
Between open Form B contacts
Between Form B contact and coil
5,000 Vrms for 1 min. (Detection current: 10mA)
5,000 Vrms for 1 min. (Detection current: 10mA)
Breakdown
voltage
(Initial)
1,000 Vrms for 1 min. (Detection current: 10mA)
2,000 Vrms for 1 min. (Detection current: 10mA)
Electrical
characteristics
Between Form A contact and
Form B contact
5,000 Vrms for 1 min. (Detection current: 10mA)
Surge breakdown voltage*2
(Between contact and coil)
10,000V (Between Form A contact and coil) (Initial)
2,500V (Between Form B contact and coil) (Initial)
30 to 110%V (Form A contact carrying current: 35A, at –40 to +55°C –40 to +131°F)
30 to 60%V (Form A contact carrying current: 35A, at –40 to +85°C –40 to +185°F)
Max. 30 ms (at nominal coil voltage, excluding contact bounce time)
Max. 10 ms (at nominal coil voltage, excluding contact bounce time, without diode)
98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 μs)
980 m/s2 (Half-wave pulse of sine wave: 6 ms)
Coil holding voltage*3
Operate time (at 20°C 68°F) (Initial)
Release time (at 20°C 68°F)*4 (Initial)
Functional
Shock
resistance
Destructive
Functional
Destructive
Mechanical
characteristics
10 to 55 Hz at double amplitude of 1.0 mm .039 inch (Detection time: 10 μs)
10 to 55 Hz at double amplitude of 1.5 mm .059 inch
Vibration
resistance
Mechanical
Min. 5×106 (at 180 times/min.)
Min. 3×104 (35A 277V AC) (ON : OFF = 1s : 9s) Min. 5×104 (35A 277V AC) (ON : OFF = 1s : 9s)
Resistive load
—
Min. 1×105 (30A 220V AC) (ON : OFF = 1s : 9s)
Min. 1×105 (20A 277V AC) (ON : OFF = 1s : 9s) Min. 2×105 (20A 277V AC) (ON : OFF = 1s : 9s)
Electrical
(Form A
contact)
Expected life
Min. 3×104 (35A 250V AC) (cosφ = 0.8)
Min. 5×104 (35A 250V AC) (cosφ = 0.8)
Inductive load
Resistive load
(ON : OFF = 0.1s : 10s)
(ON : OFF = 0.1s : 10s)
Min. 1×105 (1A 277V AC) (ON : OFF = 1s : 9s)
Electrical
(Form B
Min. 1×105 (1A 30V DC) (ON : OFF = 1s : 9s)
contact)*6
Temperature: –40 to +55°C –40 to +131°F (Coil holding voltage 30 to 110%V)
Temperature: –40 to +85°C –40 to +185°F (Coil holding voltage 30 to 60%V or storage)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Air pressure: 86 to 106 kPa
Conditions
Unit weight
Conditions for operation, transport and storage*5
Approx. 64 g 2.26 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2×50μs according to JEC-212-1981
*3. Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage.
*4. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.
*5. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*6. Regarding Form B contact, only the 2 Form A 1 Form B type applies.
ASCTB360E 201604-T
–3–
HE-S (AHES3, 4)
REFERENCE DATA
1. Maximum switching power
2. Life curve
3. Coil temperature rise
Measured portion: Inside the coil
Ambient temperature: 25°C 77°F, 85°C 185°F
Contact current: 35 A/0 A
80
100
1,000
500
176
25°C 77°F 35A
50
30
70
158
AC resistive load
60
140
20
15
250 V AC resistive
Long life type
85°C 185°F 35A
DC resistive load
10
5
100
50
50
122
25°C 77°F 0A
85°C 185°F 0A
40
104
30
86
10
1
0.5
Standard type
20
68
5
10
50
0
32
1
1
30
100
480 500 1,000
0
5
10 15 20 25 30 35 40
Contact current, A
50
60
70
80
90
100 110
Coil applied voltage, %V
Contact voltage, V
4. Ambient temperature characteristics
Tested sample: AHES3191, 6 pcs.
30
20
10
-60 -40 -20
0
-76 -40 -4 32
0
20 40 60 80 100
68 104 140 176 212
Pick-up
voltage
-10
-20
-30
Drop-out
voltage
Ambient temperature, °C °F
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/
DIMENSIONS (mm inch)
1. 2 Form A type
CAD Data
Schematic (Bottom view)
30.0
1.181
36.0
1.417
4
5
(38.0)
40.0
2
1
7
8
(1.496)
1.575
2.4
.094
Recommended PC board pattern
(Bottom view)
2.0
.079
27.0
1.063
24.4
.961
29.4
1.157
4.0
.157
7.6
.299
7.6
.299
21.3
.839
21.3
.839
11.0
.433
4-0.8
4-.031
4-3.3
4-.130
11.0
.433
1.0
.039
19.0
.748
4.0
.157
General tolerance: 0.3 .012
19.0
.748
1.6
.063
Tolerance: 0.1 .004
ASCTB360E 201604-T
–4–
HE-S (AHES3, 4)
2. 2 Form A 1 Form B type
CAD Data
Schematic (Bottom view)
30.0
1.181
36.0
1.417
3
4
5
6
(38.0)
(1.496)
40.0
1.575
2
7
1
8
2.4
.094
Recommended PC board pattern
(Bottom view)
2.0
.079
27.0
1.063
22.9
24.4
.961
29.4
1.157
4.0
.157
2-1.2
2-.047
.902
7.6
.299
2-1.2
2-.047
22.9
.902
7.6
.299
21.3
.839
21.3
.839
11.0
.433
4-0.8
4-.031
11.0
.433
4-3.3
4-.130
1.0
.039
19.0
.748
4.0
.157
19.0
1.6
General tolerance: 0.3 .012
.748
.063
Tolerance: 0.1 .004
SAFETY STANDARDS
N.O. contact (Form A contact)
N.C. contact (Form B contact)
Item
Certification
File No.
E43149
Contact rating
Temp.
Cycles
Contact rating
Temp.
Cycles
—
35A, 277VAC, Resistive
20A, 277VAC, Resistive
15A, 480VAC, Resistive
TV-8
85°C 185°F
85°C 185°F
85°C 185°F
40°C 104°F
3×104
105
105
25×103
2 Form A
—
—
UL/C-UL
(Recognized)
1A, 30VDC, Resistive
1A, 277VAC, Resistive
85°C 185°F
85°C 185°F
105
105
2 Form A 1 Form B
2 Form A
Standard type
(AHES∗19∗)
—
AC-7a: 35A, 250VAC, cosφ = 0.8 85°C 185°F
40042442 AC-3: 12A, 230VAC, cosφ = 0.45 85°C 185°F
AC-3: 8A, 480VAC, cosφ = 0.45 85°C 185°F
3×104
3×104
3×104
—
—
VDE
(Certified)
2 Form A 1 Form B
DC-13: 1A, 24VDC, L/R = 48ms
85°C 185°F
8×104
N.O. contact (Form A contact)
N.C. contact (Form B contact)
Item
Certification
File No.
E43149
Contact rating
Temp.
Cycles
Contact rating
Temp.
Cycles
—
35A, 277VAC, Resistive
20A, 277VAC, Resistive
15A, 480VAC, Resistive
TV-10
85°C 185°F
85°C 185°F
85°C 185°F
40°C 104°F
5×104
2×105
105
25×103
2 Form A
2 Form A 1 Form B
2 Form A
—
—
UL/C-UL
(Recognized)
1A, 30VDC, Resistive
1A, 277VAC, Resistive
85°C 185°F
85°C 185°F
105
105
Long life type
(AHES∗29∗)
AC-7a: 35A, 250VAC, cosφ = 0.8 85°C 185°F
40042442 AC-3: 12A, 230VAC, cosφ = 0.45 85°C 185°F
AC-3: 8A, 480VAC, cosφ = 0.45 85°C 185°F
3×104
3×104
3×104
—
—
—
VDE
(Certified)
2 Form A 1 Form B
DC-13: 1A, 24VDC, L/R = 48ms
85°C 185°F
8×104
EN/IEC VDE Certified
INSULATION CHARACTERISTIC (IEC61810-1)
Item
Clearance/Creepage distance (IEC61810-1)
Category of protection (IEC61810-1)
Tracking resistance (IEC60112)
Insulation material group
Characteristic (Form A contact)
Min. 5.5mm .217inch/8.0mm .315inch
RT II
PTI 175
III a
Over voltage category
III
Rated voltage
250V
3
Pollution degree
Type of insulation (Between contact and coil)
Type of insulation (Between open contacts)
Reinforced insulation
Full disconnection
ASCTB360E 201604-T
–5–
HE-S (AHES3, 4)
NOTES
1. For cautions for use, please refer to our web site.
(https://www3.panasonic.biz/ac/e/control/relay/cautions_use/index.jsp)
2. When coil holding voltage controlled by PWM, check coil holding voltage and operation of relay under the actual
condition.
3. Usage, transport and storage conditions
1) Temperature:
–40 to +55°C –40 to +131°F (When applied coil holding voltage is 30% to 110%V of nominal coil voltage)
–40 to +85°C –40 to +185°F (When applied coil holding voltage is 30% to 60%V of nominal coil voltage or storage)
2) Humidity: 5 to 85% RH (Not freezing and condensing at low temperature)
In addition the humidity range depends on temperature. The allowable ranges are as follows;
3) Air pressure: 86 to 106 kPa
Allowable range of temperature and humidity for operation, transport and storage.
[Coil holding voltage: 30% to 110%V]
[Coil holding voltage: 30% to 60%V]
Humidity, %RH
Humidity, %RH
85
85
Tolerance range
Tolerance range
(Avoid freezing (Avoid
(Avoid freezing (Avoid
when used at
temperatures
lower than
condensation
when used at
temperatures
higher than
0°C 32°F)
when used at
temperatures
lower than
condensation
when used at
temperatures
higher than
0°C 32°F)
5
0°C 32°F)
0°C 32°F)
5
–40
–40
0
55
+131
–40
–40
0
85
+185
+32
Temperature, °C °F
+32
Temperature, °C °F
4. Solder and cleaning conditions
1) Please obey the following conditions when soldering automatically.
(1) Pre-heating: within 120°C 248°F (solder surface terminal portion) and within 120 seconds
(2) Soldering iron: 260°C 5°C 500°F 41°F (solder temperature) and within 10 seconds (soldering time)
2) In case of manual soldering, following conditions should be observed.
• Max. 270°C 518°F (solder temperature) within 10 seconds (soldering time)
• Max. 350°C 662°F (solder temperature) within 5 seconds (soldering time)
* Effects of soldering heat on the relays vary depending on the PC board. So please confirm actual soldering condition with the PC
board used for assembling.
3) Do not clean this relay by immersion, since the relay is not sealed.
Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay.
ASCTB360E 201604-T
–6–
相关型号:
©2020 ICPDF网 联系我们和版权申明