Compact size 2 Form A and  
2 Form A 1 Form B 35A power  
relays for energy management  
and industrial equipment  
HE-S RELAYS  
TYPICAL APPLICATIONS  
w
Ne  
• Photovoltaic power generation systems (Solar inverter)  
• Uninterruptible Power Supplies (UPS)  
• Inverter  
• Office air conditioner  
• Industrial equipment  
RoHS compliant  
Protective construction: Flux-resistant type  
FEATURES  
1. High-capacity and long life 35A 277V AC 5×104 (long life  
7. Contact gap (initial)  
type)  
• Form A contact: Min. 3.2 mm .126 inch/each contact  
• Form B contact: Min. 0.7 mm .028 inch  
Min. 0.5 mm .020 inch (When Form A contact  
welded)  
2. Electrical life (resistive load)  
Form A contact  
Standard type  
Long life type  
35A 277V AC  
30A 220V AC  
20A 277V AC  
3×104  
5×104  
1×105  
2×105  
8. Mirror contact mechanisms (Compliant with EN60947-4-1  
mirror contact)  
1×105  
3. Compact size and low operating power  
W: 30 × L: 36 × H: 40 mm W: 1.181 × L: 1.417 × H: 1.575 inch  
Operating power: 1,880 mW (holding power: 170 mW)  
Detection of main contact welding makes it possible to  
construct a safety circuit.  
• Designed so that Form A contact and Form B contact will  
4. Reduced coil holding voltage contributes to saving  
energy of equipment  
The coil holding voltage can be reduced up to 30%V of the  
nominal coil voltage. This equals to operating power of  
approximately 170 mW, which contributes equipment energy  
savings.  
not close at the same time.  
• When Form A contact welded, Form B contact gap of at  
least 0.5 mm .020 inch is maintained.  
* Form B contact, when used to monitor the condition of Form A contact, can be  
used exclusively as an auxiliary contact.  
When Form A  
contact welded  
Normal operation  
Non-excitation Excitation  
Condi-  
tions  
* Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil  
voltage.  
Non-excitation  
5. Contact gap: 3.2 mm .126 inch (VDE0126 compliant)  
Compliant with European photovoltaic standard VDE0126  
Compliant with EN61810-1 2.5 kV surge breakdown voltage  
(between contacts)  
Form A  
contact  
Form B  
contact  
Form A  
contact  
Form B  
contact  
Form A  
contact  
Form B  
contact  
Mirror  
contact  
mecha-  
nisms  
Welding  
6. Insulation distance (initial)  
• Between Form A contact and coil: Min. 11.0 mm .433 inch  
(Clearance/Creepage)  
• Between Form B contact and coil: Min. 3.2 mm .126 inch  
(Clearance/Creepage)  
• Between Form A contact sets: Min. 8.2 mm .323 inch  
(Clearance/Creepage)  
• Between Form A contact and Form B contact: Min. 12.8 mm  
.504 inch (Clearance/Creepage)  
ASCTB360E 201604-T  
–1–  
HE-S (AHES3, 4)  
ORDERING INFORMATION  
AHES  
9
Contact arrangement / Operating function  
3: 2 Form A Single side stable type  
4: 2 Form A 1 Form B Single side stable type  
Contact specifications  
1: Standard type  
2: Long life type  
Terminals form  
9: PC board terminal type  
Nominal coil voltage (DC)  
Part No.  
0 1 2 3 5  
Nominal coil voltage (V)  
6 12 24 48 9  
Note: Certified by UL/C-UL and VDE  
TYPES  
Part No.  
Contact arrangement  
Nominal coil voltage  
Standard type  
AHES3190  
AHES3195  
AHES3191  
AHES3192  
AHES3193  
AHES4190  
AHES4195  
AHES4191  
AHES4192  
AHES4193  
Long life type  
AHES3290  
AHES3295  
AHES3291  
AHES3292  
AHES3293  
AHES4290  
AHES4295  
AHES4291  
AHES4292  
AHES4293  
6V DC  
9V DC  
2 Form A  
12V DC  
24V DC  
48V DC  
6V DC  
9V DC  
2 Form A 1 Form B  
12V DC  
24V DC  
48V DC  
Standard packing: Carton: 25 pcs.; Case: 100 pcs.  
RATING  
1. Coil data  
Pick-up voltage  
Drop-out voltage  
(at 20°C 68°F)  
(Initial)  
Nominal operating  
current  
[ 10%] (at 20°C 68°F)  
Nominal operating  
power  
(at 20°C 68°F)  
Nominal coil  
(at 20°C 68°F)  
voltage  
Coil resistance  
[ 10%] (at 20°C 68°F)  
Max. applied voltage  
(at 55°C 131°F)  
(Initial)  
6V DC  
9V DC  
313mA  
209mA  
157mA  
78mA  
19.1Ω  
43.1Ω  
76.6Ω  
306.4Ω  
1,225.5Ω  
110%V of nominal  
coil voltage  
75%V or less of  
nominal voltage  
5%V or more of  
nominal voltage  
ON: 1,880mW  
12V DC  
Holding: 170mW*1  
150%V of nominal  
coil voltage*2  
24V DC  
48V DC  
39mA  
Notes: *1. With 30%V coil holding voltage  
*2. With no more than 24 hours per time with non-consecutive voltage application time.  
ASCTB360E 201604-T  
–2–  
HE-S (AHES3, 4)  
2. Specifications  
Specifications  
Characteristics  
Item  
Standard type  
Long life type  
Arrangement  
2 Form A, 2 Form A 1 Form B  
2 Form A, 2 Form A 1 Form B  
Max. 100mΩ (By voltage drop 6V DC 1A),  
Contact resistance (Initial)  
Form A  
contact  
Max. 3mΩ (By voltage drop 6V DC 20A, Reference value)  
Contact  
Contact material  
AgSnO2 type  
Max. 100mΩ (By voltage drop 6V DC 1A)  
Au flashed AgNi type  
Contact resistance (Initial)  
Contact material  
Form B  
contact*6  
Nominal switching capacity  
(Resistive load)  
35A 277V AC  
480V AC, 110V DC  
9,695VA  
Max. switching voltage  
Form A  
contact  
Contact carring power  
(Resistive load)  
Max. switching current  
35A  
Min. switching capacity  
(Reference value)*1  
100mA 5V DC  
Nominal switching capacity  
(Resistive load)  
1A 277V AC, 1A 30V DC  
277V AC, 30V DC  
277VA  
Rating  
Max. switching voltage  
Form B  
Contact carring power  
(Resistive load)  
contact*6  
Max. switching current  
1A  
Min. switching capacity  
(Reference value)*1  
10mA 5V DC  
1,880mW (after applying min.100ms coil nominal voltage)  
170mW (30%V of coil holding voltage)  
Nominal operating power  
Insulation resistance (Initial)  
Min. 1,000MΩ (at 500 V DC) Measurement at same location as “Breakdown voltage” section.  
Max. 1,000A 1 ms, 3 times (Reference value)  
Short current (A contact, Initial)  
Between open Form A contacts  
2,000 Vrms for 1 min. (Detection current: 10mA)  
Between Form A contact and coil  
Between Form A contact sets  
Between open Form B contacts  
Between Form B contact and coil  
5,000 Vrms for 1 min. (Detection current: 10mA)  
5,000 Vrms for 1 min. (Detection current: 10mA)  
Breakdown  
voltage  
(Initial)  
1,000 Vrms for 1 min. (Detection current: 10mA)  
2,000 Vrms for 1 min. (Detection current: 10mA)  
Electrical  
characteristics  
Between Form A contact and  
Form B contact  
5,000 Vrms for 1 min. (Detection current: 10mA)  
Surge breakdown voltage*2  
(Between contact and coil)  
10,000V (Between Form A contact and coil) (Initial)  
2,500V (Between Form B contact and coil) (Initial)  
30 to 110%V (Form A contact carrying current: 35A, at –40 to +55°C –40 to +131°F)  
30 to 60%V (Form A contact carrying current: 35A, at –40 to +85°C –40 to +185°F)  
Max. 30 ms (at nominal coil voltage, excluding contact bounce time)  
Max. 10 ms (at nominal coil voltage, excluding contact bounce time, without diode)  
98 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10 μs)  
980 m/s2 (Half-wave pulse of sine wave: 6 ms)  
Coil holding voltage*3  
Operate time (at 20°C 68°F) (Initial)  
Release time (at 20°C 68°F)*4 (Initial)  
Functional  
Shock  
resistance  
Destructive  
Functional  
Destructive  
Mechanical  
characteristics  
10 to 55 Hz at double amplitude of 1.0 mm .039 inch (Detection time: 10 μs)  
10 to 55 Hz at double amplitude of 1.5 mm .059 inch  
Vibration  
resistance  
Mechanical  
Min. 5×106 (at 180 times/min.)  
Min. 3×104 (35A 277V AC) (ON : OFF = 1s : 9s) Min. 5×104 (35A 277V AC) (ON : OFF = 1s : 9s)  
Resistive load  
Min. 1×105 (30A 220V AC) (ON : OFF = 1s : 9s)  
Min. 1×105 (20A 277V AC) (ON : OFF = 1s : 9s) Min. 2×105 (20A 277V AC) (ON : OFF = 1s : 9s)  
Electrical  
(Form A  
contact)  
Expected life  
Min. 3×104 (35A 250V AC) (cosφ = 0.8)  
Min. 5×104 (35A 250V AC) (cosφ = 0.8)  
Inductive load  
Resistive load  
(ON : OFF = 0.1s : 10s)  
(ON : OFF = 0.1s : 10s)  
Min. 1×105 (1A 277V AC) (ON : OFF = 1s : 9s)  
Electrical  
(Form B  
Min. 1×105 (1A 30V DC) (ON : OFF = 1s : 9s)  
contact)*6  
Temperature: –40 to +55°C –40 to +131°F (Coil holding voltage 30 to 110%V)  
Temperature: –40 to +85°C –40 to +185°F (Coil holding voltage 30 to 60%V or storage)  
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)  
Air pressure: 86 to 106 kPa  
Conditions  
Unit weight  
Conditions for operation, transport and storage*5  
Approx. 64 g 2.26 oz  
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the  
actual load.  
*2. Wave is standard shock voltage of 1.2×50μs according to JEC-212-1981  
*3. Coil holding voltage is the coil voltage after 100 ms from the applied nominal coil voltage.  
*4. Release time will lengthen if a diode, etc., is connected in parallel to the coil. Be sure to verify operation under actual conditions.  
*5. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage  
conditions in NOTES.  
*6. Regarding Form B contact, only the 2 Form A 1 Form B type applies.  
ASCTB360E 201604-T  
–3–  
HE-S (AHES3, 4)  
REFERENCE DATA  
1. Maximum switching power  
2. Life curve  
3. Coil temperature rise  
Measured portion: Inside the coil  
Ambient temperature: 25°C 77°F, 85°C 185°F  
Contact current: 35 A/0 A  
80  
100  
1,000  
500  
176  
25°C 77°F 35A  
50  
30  
70  
158  
AC resistive load  
60  
140  
20  
15  
250 V AC resistive  
Long life type  
85°C 185°F 35A  
DC resistive load  
10  
5
100  
50  
50  
122  
25°C 77°F 0A  
85°C 185°F 0A  
40  
104  
30  
86  
10  
1
0.5  
Standard type  
20  
68  
5
10  
50  
0
32  
1
1
30  
100  
480 500 1,000  
0
5
10 15 20 25 30 35 40  
Contact current, A  
50  
60  
70  
80  
90  
100 110  
Coil applied voltage, %V  
Contact voltage, V  
4. Ambient temperature characteristics  
Tested sample: AHES3191, 6 pcs.  
30  
20  
10  
-60 -40 -20  
0
-76 -40 -4 32  
0
20 40 60 80 100  
68 104 140 176 212  
Pick-up  
voltage  
-10  
-20  
-30  
Drop-out  
voltage  
Ambient temperature, °C °F  
The CAD data of the products with a CAD Data mark can be downloaded from: http://industrial.panasonic.com/ac/e/  
DIMENSIONS (mm inch)  
1. 2 Form A type  
CAD Data  
Schematic (Bottom view)  
30.0  
1.181  
36.0  
1.417  
4
5
(38.0)  
40.0  
2
1
7
8
(1.496)  
1.575  
2.4  
.094  
Recommended PC board pattern  
(Bottom view)  
2.0  
.079  
27.0  
1.063  
24.4  
.961  
29.4  
1.157  
4.0  
.157  
7.6  
.299  
7.6  
.299  
21.3  
.839  
21.3  
.839  
11.0  
.433  
4-0.8  
4-.031  
4-3.3  
4-.130  
11.0  
.433  
1.0  
.039  
19.0  
.748  
4.0  
.157  
General tolerance: 0.3 .012  
19.0  
.748  
1.6  
.063  
Tolerance: 0.1 .004  
ASCTB360E 201604-T  
–4–  
HE-S (AHES3, 4)  
2. 2 Form A 1 Form B type  
CAD Data  
Schematic (Bottom view)  
30.0  
1.181  
36.0  
1.417  
3
4
5
6
(38.0)  
(1.496)  
40.0  
1.575  
2
7
1
8
2.4  
.094  
Recommended PC board pattern  
(Bottom view)  
2.0  
.079  
27.0  
1.063  
22.9  
24.4  
.961  
29.4  
1.157  
4.0  
.157  
2-1.2  
2-.047  
.902  
7.6  
.299  
2-1.2  
2-.047  
22.9  
.902  
7.6  
.299  
21.3  
.839  
21.3  
.839  
11.0  
.433  
4-0.8  
4-.031  
11.0  
.433  
4-3.3  
4-.130  
1.0  
.039  
19.0  
.748  
4.0  
.157  
19.0  
1.6  
General tolerance: 0.3 .012  
.748  
.063  
Tolerance: 0.1 .004  
SAFETY STANDARDS  
N.O. contact (Form A contact)  
N.C. contact (Form B contact)  
Item  
Certification  
File No.  
E43149  
Contact rating  
Temp.  
Cycles  
Contact rating  
Temp.  
Cycles  
35A, 277VAC, Resistive  
20A, 277VAC, Resistive  
15A, 480VAC, Resistive  
TV-8  
85°C 185°F  
85°C 185°F  
85°C 185°F  
40°C 104°F  
3×104  
105  
105  
25×103  
2 Form A  
UL/C-UL  
(Recognized)  
1A, 30VDC, Resistive  
1A, 277VAC, Resistive  
85°C 185°F  
85°C 185°F  
105  
105  
2 Form A 1 Form B  
2 Form A  
Standard type  
(AHES19)  
AC-7a: 35A, 250VAC, cosφ = 0.8 85°C 185°F  
40042442 AC-3: 12A, 230VAC, cosφ = 0.45 85°C 185°F  
AC-3: 8A, 480VAC, cosφ = 0.45 85°C 185°F  
3×104  
3×104  
3×104  
VDE  
(Certified)  
2 Form A 1 Form B  
DC-13: 1A, 24VDC, L/R = 48ms  
85°C 185°F  
8×104  
N.O. contact (Form A contact)  
N.C. contact (Form B contact)  
Item  
Certification  
File No.  
E43149  
Contact rating  
Temp.  
Cycles  
Contact rating  
Temp.  
Cycles  
35A, 277VAC, Resistive  
20A, 277VAC, Resistive  
15A, 480VAC, Resistive  
TV-10  
85°C 185°F  
85°C 185°F  
85°C 185°F  
40°C 104°F  
5×104  
2×105  
105  
25×103  
2 Form A  
2 Form A 1 Form B  
2 Form A  
UL/C-UL  
(Recognized)  
1A, 30VDC, Resistive  
1A, 277VAC, Resistive  
85°C 185°F  
85°C 185°F  
105  
105  
Long life type  
(AHES29)  
AC-7a: 35A, 250VAC, cosφ = 0.8 85°C 185°F  
40042442 AC-3: 12A, 230VAC, cosφ = 0.45 85°C 185°F  
AC-3: 8A, 480VAC, cosφ = 0.45 85°C 185°F  
3×104  
3×104  
3×104  
VDE  
(Certified)  
2 Form A 1 Form B  
DC-13: 1A, 24VDC, L/R = 48ms  
85°C 185°F  
8×104  
EN/IEC VDE Certified  
INSULATION CHARACTERISTIC (IEC61810-1)  
Item  
Clearance/Creepage distance (IEC61810-1)  
Category of protection (IEC61810-1)  
Tracking resistance (IEC60112)  
Insulation material group  
Characteristic (Form A contact)  
Min. 5.5mm .217inch/8.0mm .315inch  
RT II  
PTI 175  
III a  
Over voltage category  
III  
Rated voltage  
250V  
3
Pollution degree  
Type of insulation (Between contact and coil)  
Type of insulation (Between open contacts)  
Reinforced insulation  
Full disconnection  
ASCTB360E 201604-T  
–5–  
HE-S (AHES3, 4)  
NOTES  
1. For cautions for use, please refer to our web site.  
(https://www3.panasonic.biz/ac/e/control/relay/cautions_use/index.jsp)  
2. When coil holding voltage controlled by PWM, check coil holding voltage and operation of relay under the actual  
condition.  
3. Usage, transport and storage conditions  
1) Temperature:  
–40 to +55°C –40 to +131°F (When applied coil holding voltage is 30% to 110%V of nominal coil voltage)  
–40 to +85°C –40 to +185°F (When applied coil holding voltage is 30% to 60%V of nominal coil voltage or storage)  
2) Humidity: 5 to 85% RH (Not freezing and condensing at low temperature)  
In addition the humidity range depends on temperature. The allowable ranges are as follows;  
3) Air pressure: 86 to 106 kPa  
Allowable range of temperature and humidity for operation, transport and storage.  
[Coil holding voltage: 30% to 110%V]  
[Coil holding voltage: 30% to 60%V]  
Humidity, %RH  
Humidity, %RH  
85  
85  
Tolerance range  
Tolerance range  
(Avoid freezing (Avoid  
(Avoid freezing (Avoid  
when used at  
temperatures  
lower than  
condensation  
when used at  
temperatures  
higher than  
0°C 32°F)  
when used at  
temperatures  
lower than  
condensation  
when used at  
temperatures  
higher than  
0°C 32°F)  
5
0°C 32°F)  
0°C 32°F)  
5
–40  
–40  
0
55  
+131  
–40  
–40  
0
85  
+185  
+32  
Temperature, °C °F  
+32  
Temperature, °C °F  
4. Solder and cleaning conditions  
1) Please obey the following conditions when soldering automatically.  
(1) Pre-heating: within 120°C 248°F (solder surface terminal portion) and within 120 seconds  
(2) Soldering iron: 260°C 5°C 500°F 41°F (solder temperature) and within 10 seconds (soldering time)  
2) In case of manual soldering, following conditions should be observed.  
• Max. 270°C 518°F (solder temperature) within 10 seconds (soldering time)  
• Max. 350°C 662°F (solder temperature) within 5 seconds (soldering time)  
* Effects of soldering heat on the relays vary depending on the PC board. So please confirm actual soldering condition with the PC  
board used for assembling.  
3) Do not clean this relay by immersion, since the relay is not sealed.  
Also, be careful not to allow flux to overflow above the PC board or enter the inside of the relay.  
ASCTB360E 201604-T  
–6–  

相关型号:

AHES4192

Power/Signal Relay,
PANASONIC

AHES4195

Power/Signal Relay
PANASONIC

AHES4292

Power/Signal Relay,
PANASONIC

AHES4293

Power/Signal Relay
PANASONIC

AHF-10

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10D12

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10D15

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10S03

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10S05

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10S12

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10S15

10 Watts Universal Input Range AC/DC Power Modules
MINMAX

AHF-10S24

10 Watts Universal Input Range AC/DC Power Modules
MINMAX