DMF-6104NB-FW [OPTREX]

LCD Module Specification; 液晶显示模块规格
DMF-6104NB-FW
型号: DMF-6104NB-FW
厂家: OPTREX CORPORATION    OPTREX CORPORATION
描述:

LCD Module Specification
液晶显示模块规格

CD
文件: 总17页 (文件大小:186K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Approved by  
Checked by  
Checked by  
Prepared by  
Production Div.  
Quality Assurance Div.  
Design Engineering Div.  
Production Div.  
First Edition  
June 2, 1997  
Final Revision  
*******  
LCD Module Specification  
Type No.  
DMF6104NB-FW  
Table of Contents  
1. General Specifications .............................................................................2  
2. Electrical Specifications...........................................................................3  
3. Optical Specifications ..............................................................................8  
4. I/O Terminal...........................................................................................10  
5. Test..........................................................................................................12  
6. Appearance Standards............................................................................13  
7. Code System of Production Lot ..........................................................16  
8. Type Number .........................................................................................16  
9. Applying Precautions.............................................................................16  
10. Handling Precautions.............................................................................17  
Revision History  
Rev.  
Date  
Page  
Comment  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 1/17  
OPTREX  
1.General Specifications  
Operating Temp.  
Storage Temp.  
Dot Pixels  
min. 10℃ ~ max. 40℃  
min. -20℃ ~ max. 60℃  
256 (W) × 128 (H) dots  
0.43 (W) × 0.43 (H) mm  
0.47 (W) × 0.47 (H) mm  
127.0 (W) × 70.0 (H) mm  
167.0 (W) × 116.0 (H) × 24.0 (D) mm  
250g max.  
Dot Size  
Dot Pitch  
Viewing Area  
Outline Dimensions  
Weight  
LCD Type  
NSD-7451  
( STN / Blue-mode / Transflective )  
Viewing Angle  
Data Transfer  
Backlight  
6:00  
4-bit parallel data transfer  
Cold Cathode Fluorescent Lamp (CFL) × 1  
Drawings  
Dimensional Outline  
UE-32050B  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 2/17  
OPTREX  
2.Electrical Specifications  
2.1.Absolute Maximum Ratings  
VSS=0V  
Units  
V
Parameter  
Supply Voltage  
(Logic)  
Symbol  
Conditions  
Min.  
-0.3  
Max.  
6.0  
VCC-VSS  
Supply Voltage  
(LCD Drive)  
Input Voltage  
VCC-VEE  
0
30.0  
V
V
VI  
-0.3  
VCC+0.3  
2.2.DC Characteristics  
Ta=25, VSS=0V  
Parameter  
Supply Voltage  
(Logic)  
Symbol  
Conditions  
Min.  
4.5  
Typ.  
Max.  
5.5  
Units  
V
VCC-VSS  
Supply Voltage  
(LCD Drive)  
High Level  
VCC-VEE  
Shown in 3.1  
V
V
VIH  
VCC=5.0V±10%  
VCC=5.0V±10%  
IOH=-0.2mA  
0.8×VCC  
VCC  
0.2×VCC  
VCC  
Input Voltage  
Low Level  
VIL  
0
VCC-0.4  
0
V
Input Voltage  
High Level  
VOH  
VOL  
ICC  
V
Output Voltage  
Low Level  
IOL=0.2mA  
0.4  
V
Output Voltage  
VCC-VSS=5.0V  
VCC-VEE=13.8V  
5.0  
4.7  
20.0  
mA  
mA  
Supply Current  
IEE  
15.0  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 3/17  
OPTREX  
2.3.AC Characteristics  
V
CC=5.0V±10%  
Parameter  
Clock Pulse Width  
Symbol  
tWC  
Min.  
100  
125  
Max.  
Units  
ns  
50  
tWL  
Latch Pulse High Level Width  
Clock Pulse Rise/Fall Time  
CPLP Rise Time  
ns  
tr, tf  
tCL  
ns  
63  
ns  
tLSU2  
tLSU1  
tLC  
CPLP Fall Time  
90  
ns  
LPCP Rise Time  
90  
ns  
LPCP Fall Time  
63  
ns  
tDSU  
tDHD  
tSETUP  
tHOLD  
Data Setup Time  
50  
ns  
Data Hold Time  
80  
ns  
FLM Data Setup Time  
FLM Data Hold Time  
100  
100  
ns  
ns  
tWL  
LP  
tLSU2  
tLSU1  
tWC  
tCL  
tWC  
tLC  
CP  
tr  
tf  
tDSU  
tDHD  
D0 D3  
tSETUP  
tHOLD  
FLM  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 4/17  
OPTREX  
2.4.Timing Chart  
T=0.223ms typ.  
LP  
CP  
D0  
SEG  
SEG  
SEG  
SEG  
SEG  
SEG  
SEG  
SEG  
505  
509  
1
5
#1 + #65 DATA  
505  
509  
1
5
D3  
FLM  
LP  
508  
512  
4
8
508  
512  
4
8
(Reduction)  
×
64  
T
FLM  
(Reduction)  
2.5.Comparison of Display and Data  
SEG1  
SEG256  
D1 D0  
#1  
D3  
D2  
D1  
D0  
D0 D3  
#64  
#65  
D3  
D2  
D1  
D0  
D1  
D0  
D0 D3  
#128  
SEG257  
SEG512  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 5/17  
OPTREX  
2.6.Power Supply ON/OFF Sequence  
2.6.1.ON Sequence  
SIGNAL  
LEVEL  
VCC  
VCC  
VSS  
VCC  
VSS  
VCC  
VSS  
VEE  
VCC  
VSS  
0
t
SIGNAL  
VEE  
0
t
0
t
DISPOFF  
2.6.2.OFF Sequence  
LEVEL  
VCC  
SIGNAL  
VCC  
VSS  
VCC  
VSS  
VCC  
VSS  
VEE  
VCC  
VSS  
0
t
SIGNAL  
VEE  
0
t
0
t
DISPOFF  
Please maintain the above sequence when turning on and off the power supply of the module.  
If DISPOFF is supplied to the module while alternate signal for LCD driving (M) is unstable,  
DC component will be supplied to the LCD panel. This may cause damage the LCD module.  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 6/17  
OPTREX  
2.7.Lighting Specifications  
Ta=25℃  
Parameter  
Lamp Voltage  
Symbol  
VL  
Conditions  
Min.  
Typ.  
250  
5.0  
Max.  
Units Notes  
Vrms  
mArms  
Vrms  
cd/㎡  
hrs  
1
2
3
4
5
Lamp Current  
Starting Voltage  
Surface Luminance  
Average Life  
IL  
4.0  
600  
50  
6.0  
VS  
L
IL=5.0mA  
IL=5.0mA  
TAL  
20000  
Note 1 : The voltage ( r.m.s. ) to maintain the electric discharge of the lamp. It is measured after lighting for  
3 minutes .  
Note 2 : The current ( r.m.s. ) to flow through the lamp with the electric discharge. It is measured after  
lighting for 3 minutes.  
Note 3 : The voltage at starting the electric discharge when the voltage is increased gradually from 0V.  
Note 4 : Surface Luminance is specified by the initial data of luminance measured at the center of display  
surface after 20 minutes power on. ( All ON pattern )  
Note 5 : CFL life is defined as the time for which the initial luminance is attenuated by 50% of the  
luminance value. Average Life representes the time elapsed at the point of time when the residual  
ratio becomes below 50% when plural lamps are lighted in comparison with the definition of life  
mentioned above.  
I
C
F
L
N
V
VS  
VL  
IL  
CFL Testing Circuit  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 7/17  
OPTREX  
3.Optical Specifications  
3.1.LCD Driving Voltage  
Parameter  
Recommended  
LCD Driving Voltage  
Note 1  
Symbol  
Conditions  
Ta=10℃  
Ta=25℃  
Ta=40℃  
Min.  
Typ.  
Max.  
16.3  
14.8  
Units  
V
VCC-VEE  
12.8  
11.5  
13.8  
V
V
Note 1 :  
Voltage (Applied actual waveform to LCD Module) for the best contrast. The range of  
minimum and maximum shows tolerance of the operating voltage. The specified contrast ratio and  
response time are not guaranteed over the entire range.  
3.2.Optical Characteristics  
Ta=25, 1/64 Duty, 1/9 Bias, VD=13.8V (Note 4), θ= 0, φ=-゚  
Parameter  
Symbol  
CR  
Conditions  
Min.  
Typ.  
4.5  
Max.  
Units  
Contrast Ratio  
Viewing Angle  
Note 1  
θ= 0, φ=-゚  
Shown in 3.3  
Response  
Time  
Rise Note 2  
Decay Note 3  
TON  
60  
250  
120  
380  
ms  
ms  
TOFF  
Note 1 : Contrast ratio is definded as follows.  
CR = LON / LOFF  
LON : Luminance of the ON segments  
OFF : Luminance of the OFF segments  
L
Note 2 : The time that the luminance level reaches 90% of the saturation level from 0% when ON  
signal is applied.  
Note 3 : The time that the luminance level reaches 10% of the saturation level from 100% when OFF  
signal is applied.  
Note 4 : Definition of Driving Voltage VD  
Assuming that the typical driving waveforms shown below are applied to the LCD Panel at  
1/A Duty - 1/B Bias ( A : Duty Number, B : Bias Number ). Driving voltage VD is definded  
as the voltage VO-P when the contrast ratio (CR=LON / LOFF) is at its maximum.  
VO-P  
×
( B-2 ) VO-P / B  
×
1 / ( fF A )  
1 / fF  
ON SIGNAL  
OFF SIGNAL  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 8/17  
OPTREX  
3.3.Definition of Viewing Angle and Optimum Viewing Area  
Point shows the point where contrast ratio is measured. : θ= 0, φ=-゚  
f
Driving condition : 1/64 Duty, 1/9 Bias, VD=13.8V, F=70Hz  
90  
45  
135  
θ
90  
φ
φ
゚)  
180  
10 20 30 40 50  
θ
(
= 0  
φ
0
180  
225  
315  
270  
270  
Area  
shows typ. CR2  
3.4.System Block Diagram  
Temperature Chamber  
Rotation Table (  
θ φ  
,
)
Photometer  
#1980A WB  
LCD  
φ
Optical Fiber  
θ
Control Unit &  
Computer  
Waveform Generator  
Halogen bulb  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 9/17  
OPTREX  
4.I/O Terminal  
4.1.Pin Assignment  
No.  
1
Symbol  
VCC  
VSS  
Level  
Function  
Power Supply for Logic  
Power Supply (0V, GND)  
2
VEE  
Power Supply for LCD Drive  
Data Latch Signal  
3
LP  
HL  
H / L  
H / L  
4
M
Alternate Signal for LCD Drive  
Display Control Signal H : Display on L : Display off  
Non-connection  
5
DISPOFF  
NC  
6
7
FLM  
CP  
H / L  
HL  
First Line Marker  
8
Clock Signal for Shifting Data  
Non-connection  
9
NC  
10  
11  
12  
13  
14  
15  
16  
D0  
H / L  
H / L  
H / L  
H / L  
Display Data  
D1  
Display Data  
D2  
Display Data  
D3  
Display Data  
FL  
Power Supply for CFL (HOT)  
Power Supply for CFL (GND)  
FL (GND)  
4.2.Example of Power Supply  
It is recommended to apply a potentiometer for the contrast adjust due to the tolerance  
of the driving voltage and its temperature dependence.  
VCC  
VEE  
VCC (+Voltage)  
R1  
VR  
R2  
Tr  
MODULE  
VEE (-Voltage)  
VSS (0V)  
VSS  
Ω
R1+R2+VR=10 20K  
Tr=2SA1202 or equivalent  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 10/17  
OPTREX  
4.3.Block Diagram  
4
D0 D3  
CP  
DISPOFF  
LP  
Column Driver  
×
MSM5299  
3
or equivalent  
M
FLM  
240  
64  
64  
Row Driver  
L C D P  
×
16  
MSM5298  
1
×
or equivalent  
256  
128 dots  
256  
4
Column Driver  
×
MSM5299  
or equivalent  
4
VCC  
VSS  
Bias Circuit  
To LSI  
VEE  
FL  
CFL Backlight  
FL (GND)  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 11/17  
OPTREX  
5.Test  
No change on display and in operation under the following test condition.  
No.  
1
Parameter  
Conditions  
40℃±2, 96hrs (operation state)  
10℃±2, 96hrs (operation state)  
60℃±2, 96hrs  
Notes  
High Temperature Operating  
Low Temperature Operating  
High Temperature Storage  
Low Temperature Storage  
Damp Proof Test  
2
3
4
3
4
-20℃±2, 96hrs  
3, 4  
3, 4  
5
5
40℃±2, 9095%RH, 96hrs  
Total fixed amplitude : 1.5mm  
Vibration Frequency : 1055Hz  
One cycle 60 seconds to 3 directions of X, Y, Z for  
each 15 minutes  
6
Vibration Test  
7
Shock Test  
To be measured after dropping from 60cm high on  
the concrete surface in packing state.  
Dropping method corner dropping  
F
A corner : once  
E
Edge dropping  
B,C,D edge : once  
D
A
G
C
B
Face dropping  
E,F,G face : once  
60cm  
Concrete Surface  
Note 1 : Unless otherwise specified, tests will be conducted under the following condition.  
Temperature : 20±5℃  
Humidity  
: 65±5%  
Note 2 : Unless otherwise specified, tests will be not conducted under functioning state.  
Note 3 : No dew condensation to be observed.  
Note 4 : The function test shall be conducted after 4 hours storage at the normal temperature and humidity  
after removed from the test chamber.  
Note 5 : Vibration test will be conducted to the product itself without putting it in a container.  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 12/17  
OPTREX  
6.Appearance Standards  
6.1.Inspection conditions  
The LCD shall be inspected under 40W white fluorescent light.  
The distance between the eyes and the sample shall be more than 30cm.  
All directions for inspecting the sample should be within 45against perpendicular line.  
45  
6.2.Definition of applicable Zones  
A Zone  
B Zone  
C Zone  
Bezel Flame  
A Zone : Active display area  
B Zone : Area from outside of "A Zone" to validity viewing area  
C Zone : Rest parts  
A Zone + B Zone = Validity viewing area  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 13/17  
OPTREX  
6.3.Standards  
No.  
1
Parameter  
Black and  
White Spots,  
Criteria  
(1) Round Shape  
Dimension (mm)  
Zone  
Acceptable Number  
Foreign Substances  
A
*
3
2
0
0
B
*
5
3
1
0
C
*
*
*
*
*
D 0.1  
0.1 D 0.2  
0.2 D 0.25  
0.25D 0.3  
0.3 D  
D = ( Long + Short ) / 2  
(2) Line Shape  
Zone  
* : Disregard  
Acceptable Number  
X (mm)  
Y (mm)  
0.03W  
A
*
B
C
*
*
*
*
2.0L  
0.05W  
0.1 W  
0.1 W  
3
3
1.0L  
3
3
In the same way (1)  
X : Length Y : Width  
* : Disregard  
Total defects shall not exceed 5.  
2
Air Bubbles  
(between glass  
& polarizer)  
Zone  
Dimension (mm)  
D 0.3  
Acceptable Number  
A
*
3
2
0
B
*
*
3
0
C
*
*
*
*
0.3 D 0.4  
0.4 D 0.6  
0.6 D  
* : Disregard  
Total defects shall not exceed 3.  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 14/17  
OPTREX  
No.  
3
Parameter  
Criteria  
The Shape of Dot  
(1) Dot Shape (with Dent)  
0.15  
As per the sketch of left hand.  
(2) Dot Shape (with Projection)  
Should not be connected to next dot.  
(3) Pin Hole  
X
(X+Y) / 20.2mm  
Y
(Less than 0.1mm is no counted.)  
(4) Deformation  
(X+Y) / 20.2mm  
Y
X
Total acceptable number : 1/dot, 5/cell  
(Defect number of (4) : 1pc.)  
4
5
Polarizer Scratches  
Polarizer Dirts  
Not to be conspicuous defects.  
If the stains are removed easily from LCDP surface, the module is not  
defective.  
6
7
Complex Foreign  
Substance Defects  
Distance between  
Different Foreign  
Substance Defects  
Black spots, line shaped foreign substances or air bubbles between  
glass & polarizer should be 5pcs maximum in total.  
D0.2 : 20mm or more  
0.2D : 40mm or more  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 15/17  
OPTREX  
7.Code System of Production Lot  
The production lot of module is specified as follows :  
Factory Number  
Factory Code (Alphabet)  
Production Week (15)  
Production Month (19, X, Y, Z)  
Production Year (Lower 2 digits)  
8.Type Number  
The type number of module is specified on the back of module as follows :  
DMF6104N B-FW  
Stamp  
Etching or Printing  
9.Applying Precautions  
Please contact us when questions and/or new problems not specified in this specifications arise.  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 16/17  
OPTREX  
10.Handling Precautions  
Operex Products are designed for use in ordinary electronic devices such as business machines,  
telecommunications equipment, measurement devices and etc..  
Optrex Products are not designed, intended, or authorized for use in any application in which the failure of  
the product could result in a situation where personal injury or death may occur. These applications  
include, but are not limited to, life-sustaining equipment, nuclear control devices, aerospace equipment,  
devices related to hazardous or flammable materials, etc. (If Buyer intends to purchase or use the Optrex  
Products for such unintended or unauthorized applications, Buyer must secure prior written consent to  
such use by a responsible officer of Optrex Corporation.) Should Buyer purchase or use Optrex Products  
for any such unintended or unauthorized application (without such consent), Buyer shall indemnify and  
hold Optrex and its officers, employees, subsidiaries, affiliates and distributors harmless against all claims,  
costs, damages and expenses, and reasonable attorney's fees, arising out of, directly or indirectly, any  
claim of personal injury or death associated with such unintended or unauthorized use, even if such claim  
alleges that Optrex was negligent regarding the design or manufacture of the part.  
1) LCD may be broken because it is made of glass.  
2) Polarizer is a soft material and can easily be scratched.  
3) Please avoid static electricity.  
Please be sure to ground human body and electric appliances during work.  
It is preferable to use conductive mat on table and wear cotton clothes or conduction processed fiber.  
Synthetic fiber is not recommended.  
Please slowly peel off protective film, because static electricity may be charged.  
4) If it is necessary to store LCD modules for a long time, please comply with the following procedures.  
If storage condition is not satisfactory, display (especially polarizer) may be deteriorated or soldering  
I/O terminals may become difficult (some oxide is generated at I/O terminals plating).  
Store as delivered by Optrex  
If you store as unpacked, put in anti-static bag, seal its opening and store where it is not subjected to  
direct sunshine nor fluorescent lamp.  
Store at temperature 0 to +35and at low humidity. Please refer to our specification sheets for  
storage temperature range and humidity condition.  
5) The module does not contain excess current limiter.  
Please design the limiter to cut excess current in your power supply circuit.  
6) Liquid crystal may be leaked when display is broken. Never taste it. If your hands or clothes touch it,  
please immediately wash using soap.  
7) The connection between the bezel and VSS (GND) is not specified in the module.  
(Some module do not maintain connection between them.)  
Please consult OPTREX to specify the connection.  
8) A high voltage over 1000V is applied at the connector of CFL cable when the CFL inverter is  
connected and energized. Please do not touch there incidentally or accidentally to avoid a skin burn.  
And please set the cable properly in the housing to avoid a worn-out of isolated cover of cable wire.  
Optrex shall not be responsible for any infringement of industrial property rights of third parties in any  
country arising out of the application or use of Optrex Products, except which directly concern the  
structure or production of such products.  
DMF6104NB-FW (AA) No.97-0138  
OPTREX CORPORATION  
Page 17/17  
OPTREX  

相关型号:

DMF-6A-1500

DOUBLE BALANCED MIXER
MERRIMAC

DMF-8A-1700

DOUBLE BALANCED MIXERS
MERRIMAC

DMF-8A-1700

500MHz - 2000MHz RF/MICROWAVE DOUBLE BALANCED MIXER, 8dB CONVERSION LOSS-MAX, 8 PIN
CRANE

DMF-8A-250

DOUBLE BALANCED MIXERS
MERRIMAC

DMF-8A-250

0.5MHz - 500MHz RF/MICROWAVE DOUBLE BALANCED MIXER, 8dB CONVERSION LOSS-MAX, 8 PIN
CRANE

DMF-8A-500

DOUBLE BALANCED MIXERS
MERRIMAC

DMF-8A-500

10MHz - 1000MHz RF/MICROWAVE DOUBLE BALANCED MIXER, 8.5dB CONVERSION LOSS-MAX, 8 PIN
CRANE

DMF-8A-700

DOUBLE BALANCED MIXERS
MERRIMAC

DMF-8A-700

10MHz - 1500MHz RF/MICROWAVE DOUBLE BALANCED MIXER, 9.5dB CONVERSION LOSS-MAX, 8 PIN
CRANE

DMF02R

WIRE TO BOARD CONNECTORS .165 [4.20] CENTERLINES
ADAM-TECH

DMF02RF

WIRE TO BOARD CONNECTORS .165 [4.20] CENTERLINES
ADAM-TECH

DMF02RN

WIRE TO BOARD CONNECTORS .165 [4.20] CENTERLINES
ADAM-TECH