MC33348 [ONSEMI]

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS; 锂电池保护电路是否一个单元格智能电池组
MC33348
型号: MC33348
厂家: ONSEMI    ONSEMI
描述:

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
锂电池保护电路是否一个单元格智能电池组

电池
文件: 总12页 (文件大小:186K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Order this document by MC33348/D  
LITHIUM BATTERY  
PROTECTION CIRCUIT  
FOR  
ONE CELL  
SMART BATTERY PACKS  
The MC33348 is a monolithic lithium battery protection circuit that is  
designed to enhance the useful operating life of a one cell rechargeable  
battery pack. Cell protection features consist of internally trimmed charge  
and discharge voltage limits, discharge current limit detection with a  
delayed shutdown, and a virtually zero current sleepmode state when the  
cell is discharged. An additional feature includes an on–chip charge pump  
for reduced MOSFET losses while charging or discharging a low cell  
voltage battery pack. This protection circuit requires a minimum number of  
external components and is targeted for inclusion within the battery pack.  
This MC33348 is available in standard SOIC 8 lead surface mount  
package.  
SEMICONDUCTOR  
TECHNICAL DATA  
Internally Trimmed Charge and Discharge Voltage Limits  
Discharge Current Limit Detection with Delayed Shutdown  
Virtually Zero Current Sleepmode State when Cells are Discharged  
Charge Pump for Reduced Losses with a Low Cell Voltage Battery Pack  
Dedicated for One Cell Applications  
Minimum Components for Inclusion within the Battery Pack  
Available in a Low Profile Surface Mount Package  
8
1
Ordering Information shown on following page.  
D SUFFIX  
PLASTIC PACKAGE  
CASE 751  
(SO–8)  
Typical One Cell Smart Battery Pack  
V
CC  
7
Cell  
Voltage  
1
PIN CONNECTIONS  
Charge Pump  
Output  
1
2
3
4
8
7
6
5
Cell Voltage  
Test  
MC33348  
Ground  
V
CC  
3
Charge Gate  
Drive Output  
Ground  
Test  
2
Charge Pump  
Output  
Charge Gate Drive  
Common/Discharge  
Current Limit  
Discharge Gate  
Drive Output  
8
Discharge  
Gate Drive  
4
Charge  
Gate Drive  
6
5
Charge  
Gate Drive  
Common/  
Discharge  
Current Limit  
Output  
Output  
(Top View)  
This device contains 1170 active transistors.  
Motorola, Inc. 1999  
Rev 2  
MC33348  
ORDERING INFORMATION  
Charge  
Overvoltage  
Threshold (V) Hysteresis (mV)  
Charge  
Overvoltage  
Discharge  
Undervoltage  
Threshold (V)  
Discharge  
Current Limit  
Threshold (mV)  
Operating  
Temperature Range  
Device  
Package  
MC33348D–1  
MC33348D–2  
MC33348D–3  
MC33348D–4  
MC33348D–5  
MC33348D–6  
400  
200  
400  
200  
400  
200  
4.20  
2.25  
2.28  
2.30  
4.25  
4.35  
300  
T
A
= –25° to +85°C  
SO–8  
NOTE: Additional threshold limit options can be made available. Consult factory for information.  
MAXIMUM RATINGS  
Ratings  
Symbol  
Value  
Unit  
Input Voltage (Measured with Respect to Ground, Pin 3)  
Cell Voltage (Pin 1)  
Test (Pin 2)  
Discharge Gate Drive Output (Pin 4)  
Charge Gate Drive Common/Discharge Current Limit (Pin 5)  
Charge Gate Drive Output (Pin 6)  
V
IR  
V
7.5  
7.5  
18  
±11  
±11  
7.5  
10  
V
CC  
(Pin 7)  
Charge Pump Output (Pin 8)  
Thermal Resistance, Junction–to–Air  
R
°C/W  
θJA  
D Suffix, SO–8 Plastic Package, Case 751  
178  
Operating Junction Temperature (Note 1)  
Storage Temperature  
T
–40 to +150  
–55 to +150  
°C  
°C  
J
T
stg  
NOTES: 1. Tested ambient temperature range for the MC33348:  
T
= –25°C  
T
= +85°C  
low  
2. ESD data available upon request.  
high  
2
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
ELECTRICAL CHARACTERISTICS (V  
that applies (Note 1), unless otherwise noted.)  
= 4.0 V, T = 25°C, for min/max values T is the operating junction temperature range  
A A  
CC  
Characteristic  
Symbol  
Min  
Typ  
Max  
Unit  
VOLTAGE SENSING  
Cell Charging Cutoff (Pin 1 to Pin 3)  
Overvoltage Threshold, V  
–1 Suffix  
–2 Suffix  
–3 Suffix  
–4 Suffix  
Increasing, T = 25°C  
V
th(OV)  
V
Cell  
A
4.158  
4.158  
4.208  
4.208  
4.306  
4.306  
4.20  
4.20  
4.25  
4.25  
4.35  
4.35  
4.242  
4.242  
4.293  
4.293  
4.394  
4.394  
–5 Suffix  
–6 Suffix  
Overvoltage Hysteresis V  
–1 Suffix  
–2 Suffix  
–3 Suffix  
–4 Suffix  
Decreasing  
V
H
mV  
Cell  
300  
300  
300  
300  
300  
300  
–5 Suffix  
–6 Suffix  
Cell Discharging Cutoff (Pin 1 to Pin 3, T = 25°C)  
A
Undervoltage Threshold, V  
–1 Suffix  
–2 Suffix  
–3 Suffix  
–4 Suffix  
Decreasing  
V
th(UV)  
V
Cell  
2.205  
2.205  
2.234  
2.234  
2.254  
2.254  
2.25  
2.25  
2.28  
2.28  
2.30  
2.30  
2.295  
2.295  
2.326  
2.326  
2.346  
2.346  
–5 Suffix  
–6 Suffix  
Input Bias Current During Cell Voltage Sample (Pin 1)  
Cell Voltage Sampling Rate  
I
28  
µA  
IB  
t
1.0  
s
(smpl)  
CURRENT SENSING  
Discharge Current Limit (Pin 3 to Pin 5, T = 25°C)  
A
Threshold Voltage  
–1 Suffix  
–2 Suffix  
–3 Suffix  
–4 Suffix  
–5 Suffix  
–6 Suffix  
Delay  
V
mV  
th(dschg)  
360  
180  
360  
180  
360  
180  
1.0  
400  
200  
400  
200  
400  
200  
2.3  
440  
220  
440  
220  
440  
220  
4.0  
I
ms  
V
dly(dschg)  
CHARGE PUMP  
10  
Output Voltage (Pin 8, R 10 , T = 25°C)  
V
O
8.0  
10.2  
12  
L
A
TOTAL DEVICE  
Average Cell Current (T = 25°C, Battery Pack Unloaded and without  
Current Limit Fault)  
I
CC  
A
Operating (V  
= 4.0 V)  
17  
2.0  
20  
µA  
nA  
CC  
Sleepmode (V  
= 2.0 V)  
CC  
Minimum Operating Cell Voltage for Logic and Gate Drivers  
V
CC  
1.5  
V
NOTE: 1. Tested ambient temperature range for the MC33348:  
T
= –25°C  
T
= +85°C  
low  
high  
3
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
Figure 2. Discharge Current Limit  
Figure 1. Charge and Discharge  
Threshold Voltage Change versus Temperature  
Threshold Voltage Change versus Temperature  
1.2  
16  
8.0  
0
V
= 4.0 V  
CC  
0.8  
0.4  
Maximum Threshold  
Charge Limits  
0
–0.4  
–0.8  
–1.2  
Typical Threshold Change  
Typical Threshold Change  
–8.0  
–16  
–40  
–20  
0
20  
40  
60  
C)  
80  
100  
–40  
–20  
0
20  
40  
60  
C)  
80  
100  
T , AMBIENT TEMPERATURE (  
°
T , AMBIENT TEMPERATURE (  
°
A
A
Figure 3. Gate Drive Output Voltage  
versus Load Current  
Figure 4. Gate Drive Output Voltage  
versus Supply Voltage  
12  
10  
12  
10  
C
= 10 nF  
C
T
= 10 nF  
= 25°C  
O
O
Pin 2 = Gnd  
A
10  
R
T
10  
L
= 25°C  
A
8.0  
6.0  
4.0  
8.0  
6.0  
4.0  
V
= 4.15 V  
CC  
V
= 3.25 V  
0.6  
CC  
V
= 2.35 V  
0.4  
CC  
0
0.2  
0.8  
1.0  
0
1.0  
2.0  
3.0  
4.0  
5.0  
I , OUTPUT LOAD CURRENT (  
µA)  
V , SUPPLY VOLTAGE (V)  
CC  
L
Figure 5. Charge Pump Output Voltage  
versus Temperature  
Figure 6. Supply Current  
versus Supply Voltage  
2
1
0
12  
10  
10  
10  
Battery Pack Sleepmode Range  
C
R
= 10 nF  
O
L
10  
10  
11  
10  
Battery Pack Operating Range  
V
= 4.15 V  
CC  
In Regulation  
3
2
1
T = 25°C  
A
–1  
10  
1 – Battery pack unloaded without  
discharge current limit fault.  
2 – Battery pack loaded without  
discharge current limit fault.  
3 – Battery pack loaded or unloaded  
with discharge current limit fault.  
–2  
10  
10  
V
= 2.35 V  
CC  
Out of Regulation  
9.0  
–3  
–4  
8.0  
–40  
10  
–20  
0
20  
40  
60  
C)  
80  
100  
0
1.0  
2.0  
3.0  
4.0  
5.0  
T , AMBIENT TEMPERATURE (  
°
V , SUPPLY VOLTAGE (V)  
CC  
A
4
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
PROTECTION CIRCUIT OPERATING MODE TABLE  
Outputs  
MOSFET Switches  
Function  
Input Conditions  
Cell Status  
Circuit Operation  
Battery Pack Status  
Charge  
Q1  
Discharge  
Q2  
Charge  
Pump  
CELL CHARGING/DISCHARGING  
Storage or Nominal Operation:  
No current or voltage faults  
Both Charge MOSFET Q1 and Discharge MOSFET Q2 are on.  
The battery pack is available for charging or discharging.  
On  
On  
On  
Active  
Active  
CELL CHARGING FAULT/RESET  
Charge Voltage Limit Fault:  
Charge MOSFET Q1 is latched off and the cell is disconnected  
from the charging source. An internal current source pull–up is  
applied to divider resistors R1 and R2 creating a hysteresis  
On to Off  
V
Pin 1  
V  
for 1.0 s  
th(OV)  
voltage of V . The battery pack is available for discharging.  
H
Discharge current limit protection is disabled.  
Charge Voltage Limit Reset:  
< (V – V )  
Charge MOSFET Q1 will turn on when the voltage across the cell Off to On  
On  
Active  
V
falls sufficiently to overcome hysteresis voltage V . This can be  
Pin 1  
for 1.0 s  
th(OV)  
H
H
accomplished by applying a load to the battery pack. Discharge  
current limit protection is enabled.  
CELL DISCHARGING FAULT/RESET  
Discharge Current Limit Fault: Discharge MOSFET Q2 is latched off and the cell is  
(V + V disconnected from the load. Q2 will remain in the off state as long  
On  
On  
On to Off  
Off to On  
Active  
Active  
V
Pin 5  
)
Pin 3 th(dschg)  
for 3.0 ms and as V exceeds V by V . The battery pack is  
Pin 5  
Pin 3  
th(dschg)  
V
< (V  
– V )  
available for charging.  
Pin 1  
for 1.0 ms  
th(OV)  
H
Discharge Current Limit Reset:  
– V < V  
The Sense Enable circuit will reset and turn on discharge  
MOSFET Q2 when V no longer exceeds V by  
V
Pin 5  
Pin 3  
th(dschg)  
Pin 3  
Pin 5  
V . This can be accomplished by either disconnecting  
th(dschg)  
the load from the battery pack, or by connecting the battery pack  
to the charger.  
Discharge Voltage Limit Fault:  
V for three  
consecutive 1.0 s samples  
Discharge MOSFET Q2 is latched off, the cells are disconnected  
from the load, and the protection circuit enters a low current  
sleepmode state. The battery pack is available for charging.  
On  
On  
On to Off  
Off to On  
Disabled  
Active  
V
Pin 1  
th(UV)  
Discharge Voltage Limit Reset:  
The Sense Enable circuit will reset and turn on discharge  
V
Pin 3  
> (V  
+ 0.6 V)  
MOSFET Q2 when V  
accomplished by connecting the battery pack to the charger.  
exceeds V  
by 0.6 V. This can be  
Pin 5  
Pin 3  
Pin 5  
FAULTY CELL  
Discharge Voltage Limit Fault:  
1.5 V  
This condition can happen if the cell is defective (<1.5 V). The  
protection circuit logic will not function and the battery pack  
cannot be charged.  
Disabled  
Disabled  
Disabled  
V
Pin 1  
5
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
Figure 7. One Cell Smart Battery Pack  
5.1 k  
10  
C
I
0.1  
V
MC33348  
7
CC  
Cell  
Voltage  
1
R1  
Cell Voltage  
Sample  
Switch  
Over/Under  
Cell Voltage  
Detector  
&
R2  
Cell  
Reference  
R3  
Ground  
3
Test  
2
2.0 k  
Discharge  
Overcurrent  
Detector  
Over/Under  
Data Latch  
&
Ck  
Ck  
Oscillator  
En  
Control Logic  
Sense  
Enable  
Charge/Discharge  
Gate Drivers  
Charge Pump  
Charge Pump  
Output  
8
Discharge  
Gate Drive  
Output  
4
Charge  
Gate Drive  
Output  
6
5
Charge  
Gate Drive  
Common/  
Discharge  
Current Limit  
Charge  
Switch  
Q1  
C
O
Discharge  
Switch Q2  
0.01  
1.0 M  
Components C is mandatory. Refer to the Battery Pack Application text.  
I
PIN FUNCTION DESCRIPTION  
Description  
Pin  
Symbol  
Cell Voltage  
1
This input is connected to the positive terminal of the cell for voltage monitoring. Internally, the Cell  
Voltage Sample Switch applies this voltage to a resistor divider where it is compared by the Cell Voltage  
Detector to an internal reference.  
2
Test  
This pin is normally not connected and is used in testing the protection IC. An active low at this input  
resets the internal logic and turns on both MOSFET switches. Upon release, the logic becomes active and  
the cell voltage is sampled within 1.0 ms.  
3
4
Ground  
This is the protection IC ground and all voltage ratings are with respect to this pin.  
Discharge Gate Drive  
Output  
This output connects to the gate of discharge switch Q2 allowing it to enable or disable battery pack  
discharging.  
5
Charge Gate Drive  
Common/Discharge  
Current Limit  
This is a multifunction pin that is used to monitor cell discharge current and to provide a gate turn–off  
path for charge switch Q1. A discharge current limit fault is set when the battery pack load causes the  
combined voltage drop of charge switch Q1 and discharge switch Q2 to exceed the discharge current limit  
threshold voltage, V  
, with respect to Pin 3.  
th(dschg)  
6
Charge Gate Drive  
Output  
This output connects to the gate of charge switch Q1 allowing it to enable or disable battery pack  
charging.  
7
8
V
This pin is the positive supply voltage for the protection IC.  
CC  
Charge Pump Output  
This is the charge pump output. A reservoir capacitor is connected from this pin to ground.  
6
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
INTRODUCTION  
A functional description of the protection circuit blocks  
follows. Refer to the detailed block diagram shown in  
Figure 7.  
The insatiable demand for smaller lightweight portable  
electronic equipment has dramatically increased the  
requirements of battery performance. Batteries are expected  
to have higher energy densities, superior cycle life, be safe in  
operation and environmentally friendly. To address these  
high expectations, battery manufacturers have invested  
heavily in developing rechargeable lithium–based cells.  
Today’s most attractive chemistries include lithium–polymer,  
lithium–ion, and lithium–metal. Each of these chemistries  
require electronic protection in order to constrain cell  
operation to within the manufacturers limits.  
Rechargeable lithium–based cells require precise charge  
and discharge termination limits for both voltage and current  
in order to maximize cell capacity, cycle life, and to protect  
the end user from a catastrophic event. The termination limits  
are not as well defined as with older non–lithium chemistries.  
These limits are dependent upon a manufacturer’s particular  
lithium chemistry, construction technique, and intended  
application. Battery pack assemblers may also choose to  
enhance cell capacity at the expense of cycle life. In order to  
address these requirements, six versions of the MC33348  
protection circuit were developed. These devices feature  
charge overvoltage protection, discharge current limit  
protection with delayed shutdown, low operating current, a  
virtually zero current sleepmode state, and requires few  
external components to implement a complete one cell smart  
battery pack.  
Voltage Sensing  
Voltage sensing is accomplished by the use of the Cell  
Voltage Sample Switch in conjunction with the Over/Under  
Voltage Detector and Reference block. The Sample Switch  
applies the cell voltage to the top resistor of an internal  
divider string. The voltage at each of the tap points is  
sequentially polled and compared to an internal reference. If  
a limit has been exceeded, the result is stored in the  
Over/Under Data Latch and Control Logic block. The Cell  
Voltage Sample Switch is gated on for a 1.0 ms period at a  
one second repetition rate. This low duty cycle sampling  
technique reduces the average load current that the divider  
presents across the cell, thus extending the useful battery  
pack capacity. The cell voltage limits are tested in the  
following sequence:  
Figure 9. Cell Sensing Sequence  
Polling  
Sequence  
Time  
(ms)  
Tested  
Limit  
1
2
0.5  
0.5  
Overvoltage  
Undervoltage  
By incorporating this polling technique with a single  
comparator and voltage divider, a significant reduction of  
circuitry and trim elements is achieved. This results in a  
smaller die size, lower cost, and reduced operating current.  
Operating Description  
The MC33348 is specifically designed to be placed in the  
battery pack where it is continuously powered from a single  
lithium cell. In order to maintain cell operation within specified  
limits, the protection circuit senses both cell voltage and  
discharge current, and correspondingly controls the state of  
two N–channel MOSFET switches. These switches, Q1 and  
Q2, are placed in series with the negative terminal of the Cell  
and the negative terminal of the battery pack. This  
configuration allows the protection circuit to interrupt the  
appropriate charge or discharge path FET in the event that  
either a voltage threshold or the discharge current limit for the  
cell has been exceeded.  
Figure 10. Cell Voltage Limit Sampling  
From  
Cell Voltage  
Cell Voltage  
Sample Switch  
R1  
Discharge Voltage  
Threshold  
+
Over/Under  
Cell Voltage  
Detector  
&
Cell  
Voltage  
R2  
R3  
Charge Voltage  
Threshold  
Reference  
Cell Voltage  
Return  
To  
Cell Negative  
Terminal  
Figure 8. One Cell Smart Battery Pack  
The cell charge and discharge voltage limits are controlled  
by the values selected for the internal resistor divider string  
and the comparator input threshold. As the battery pack  
reaches full charge, the Cell Voltage Detector will sense an  
overvoltage fault condition when the cell exceeds the  
designed overvoltage limit. The fault information is stored in  
a data latch and charge MOSFET Q1 is turned off,  
disconnecting the battery pack from the charging source. An  
internal current source pull–up is then applied to lower tap of  
the divider, creating a hysteresis voltage. As a result of an  
overvoltage fault, the battery pack is available for  
discharging only.  
7
1
Cell  
MC33348  
3
8
4
6
5
The overvoltage fault is reset by applying a load to the  
battery pack. As the voltage across the cell falls below the  
hysteresis level, charge MOSFET Q1 will turn on and the  
current source pull–up will turn off. The battery pack will now  
be available for charging or discharging.  
Discharge  
MOSFET Q2  
Charge  
MOSFET Q1  
7
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
As the load eventually depletes the battery pack charge,  
Current Sensing  
the Cell Voltage Detector will sense an undervoltage fault  
condition when the cell falls below the designed undervoltage  
limit. After three consecutive faults are detected, discharge  
MOSFET Q2 is turned off, disconnecting the battery pack  
from the load. The protection circuit will now enter a low  
current sleepmode state. Refer to Figure 6. As a result of the  
undervoltage fault, the battery pack is available for charging  
only. The typical cutoff thresholds and hysteresis voltage are  
shown in Figure 11.  
Discharge current limit protection is internally provided by  
the MC33348. As the battery pack discharges, Pins 5 and 3  
sense the voltage drop across MOSFETs Q1 and Q2. A  
discharge current limit fault is detected if the voltage at Pin 5  
is greater than Pin 3 by 400 mV for –1, –3 and –5 suffix  
devices, or 200 mV for –2, –4 and –6 suffix devices. The fault  
information is stored in a data latch and discharge MOSFET  
Q2 is turned off, disconnecting the battery pack from the load.  
As a result of the discharge current fault, the battery pack is  
available for charging only. The discharge current limit is  
given by:  
Figure 11. Cutoff and Hysteresis Limits  
Charging  
Cutoff  
(V)  
Disharging  
Cutoff  
(V)  
V
V
th(dschg)  
th(dschg)  
R
Device  
Suffix  
Hysteresis  
(mV)  
I
Lim(dschg)  
R
R
Lim(dschg)  
DS(on)Q1  
DS(on)Q2  
–1, –2  
–3, –4  
–5, –6  
4.20  
4.25  
4.35  
300  
300  
300  
2.25  
2.28  
2.30  
The discharge current fault is reset by either disconnecting  
the load from the battery pack, or by connecting the battery  
pack to the charger. When the voltage on Pin 5 no longer  
exceeds Pin 3 byapproximatelyV  
circuit will turn on discharge MOSFET Q2.  
,theSenseEnable  
th(dschg)  
The undervoltage logic is designed to automatically reset  
if less than three consecutive faults appear. This helps to  
prevent a premature disconnection of the load during high  
current pulses when the battery pack charge is close to  
being depleted.  
The undervoltage fault is reset by applying charge current  
to the battery pack. When the voltage on Pin 3 exceeds Pin 5  
by 0.6 V, discharge MOSFET Q2 will turn on. The battery  
pack will now be available for charging or discharging.  
Figure 13. Power Supply Decoupling  
C
10  
R
5.1 k  
7
1
Cell  
Figure 12. Additional Discharge Current Limit Delay  
MC33348  
MC33348  
3
3
In order to guarantee proper discharge current limit  
operation when the battery pack output is shorted, power  
must be made available to the MC33348. This can be  
8
4
6
5
C
accomplished by decoupling the V  
input with the R/C  
dly  
R
CC  
dly  
component values shown above. The capacitor value must  
be increased to 100 µF if the discharge current limit  
shutdown delay time is extended to 40 ms as shown in  
Figure 12. A small signal schottky diode can be used in place  
of R for enhanced short circuit operation. The diode cathode  
is connected to Pin 7 and C, and the anode is connected to  
the positive terminal of the cell. The schottky diode solution  
may be a better choice in applications that have a charger  
with a relatively high open circuit voltage. These components  
can be deleted if operation of the discharge current limit is not  
required when the battery pack output is shorted.  
The discharge current limit shutdown delay time is typically  
3.0 ms. This time can be extended with the addition of  
components R and C . With an R of 5.1 k and C of 10  
dly dly dly dly  
µF, the current limit shutdown time is extended to 40 ms.  
The additional discharge current limit delay circuitry must  
not be used if the anticipated open–circuit charger voltage  
will exceed 6.0 V. When the charger causes the battery pack  
input to exceed 6.0 V, additional current will flow out of Pin 5,  
creating a voltage drop across resistor R . This voltage drop  
dly  
causes the source of MOSFET Q1 to fall below it’s gate,  
allowing it to unexpectedly turn back on.  
8
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
As previously stated in the voltage sensing operating  
low threshold MOSFETs, it may be desirable to disable the  
Charge Pump so that the maximum gate to source voltage is  
not exceeded. This can be accomplished by connecting Pin 6  
to Pin 5, and will result in an additional cell drain current of  
approximately 8.0 µA.  
description, charge MOSFET Q1 is held off during an  
overvoltage fault condition. When this condition is present,  
the discharge current limit protection function is internally  
disabled. This is required, since the voltage across Q1, in the  
off state, would exceed the current sense threshold. This  
would cause Q2 to turn off as well, preventing both charging  
and discharging of the cell. Discharge current limit protection  
is enabled whenever an overvoltage fault is not present.  
The discharge current protection circuit contains a built in  
response delay of 3.0 ms. This helps to prevent fault  
activation when the battery pack is subjected to pulsed  
currents during discharging. An additional current sense  
delay can be added as shown in Figure 12. If the battery pack  
is subjected to extremely high discharge current pulses or is  
Testing  
A test pin is provided in order to speed up device and  
battery pack testing. By grounding Pin 2, the internal logic is  
held in a reset state and both MOSFET switches are turned  
on. Upon release, the logic becomes active and the cell  
voltage is polled within 1.0 ms.  
Battery Pack Application  
The one cell smart battery pack application shown in  
Figure 7 contains a capacitor labeled C that connects  
I
shorted, the V  
pin must be decoupled from the cell. This is  
CC  
directly across the battery pack terminals. This component  
prevents excessive currents from flowing into the MC33348  
when the battery pack terminals are shorted or arced, and is  
required so that the protection circuit will have sufficient  
operating voltage during the load transient, to ensure turn off  
of discharge MOSFET Q2. Figure 13 shows the placement of  
decoupling components.  
mandatory. Capacitor C is a 100 nF ±20% ceramic leaded  
I
or surface mount type. It must be placed directly across the  
battery pack plus and minus terminals with extremely short  
lead lengths (1/16).  
Charge Pump and MOSFET Switches  
The MC33348 contains an on chip Charge Pump to  
ensure that the MOSFET switches are fully enhanced for  
reduced power losses. An external reservoir capacitor  
normally connects from the Charge Pump output to ground,  
Pins 8 and 3. The capacitor value is not critical and is usually  
within the range of 10 nF to 100 nF. The Charge Pump output  
is regulated at 10.2 V allowing the use of the more  
economical logic level MOSFETs. The main requirement in  
selecting a particular type of MOSFET switch is to consider  
the desired on–resistance at the lowest anticipated operating  
voltage of the battery pack. A table of small outline surface  
mount devices is given in Figure 14. When using extremely  
In applications where inordinately low leakage MOSFETs  
are used, the protection circuit may take a considerable  
amount of time to reset from an overcurrent fault after the  
load is removed. This situation can be remedied by providing  
a small leakage path for charging C , thus allowing Pin 5 to  
I
rapidly fall below the discharge current limit threshold. A  
1.0 megohm resistor placed across the MOSFET switches  
accomplishes this task with a minimum increase in cell  
discharge current when the battery pack is connected to a  
load.  
Figure 14. Small Outline Surface Mount MOSFET Switches  
On–Resistance () versus Gate to Source Voltage (V)  
Device  
Type  
2.5 V  
3.0 V  
4.0 V  
5.0 V  
6.0 V  
7.5 V  
9.0 V  
MMFT3055VL  
MMDF3N03HD  
MMDF4N01HD  
MMSF5N02HD  
MMDF6N02HD  
0.120 Ω  
0.065 Ω  
0.035 Ω  
0.021 Ω  
0.028 Ω  
0.115 Ω  
0.063 Ω  
0.034 Ω  
0.020 Ω  
0.026 Ω  
0.108 Ω  
0.062 Ω  
0.033 Ω  
0.018 Ω  
0.025 Ω  
0.100 Ω  
0.060 Ω  
0.033 Ω  
0.018 Ω  
0.023 Ω  
0.525 Ω  
0.042 Ω  
0.065 Ω  
0.035 Ω  
0.080 Ω  
0.037 Ω  
0.023 Ω  
0.029 Ω  
0.047 Ω  
0.043 Ω  
9
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
OUTLINE DIMENSIONS  
D SUFFIX  
PLASTIC PACKAGE  
CASE 751–05  
(SO–8)  
ISSUE S  
NOTES:  
D
A
1. DIMENSIONING AND TOLERANCING PER ASME  
Y14.5M, 1994.  
C
2. DIMENSIONS ARE IN MILLIMETERS.  
3. DIMENSION D AND E DO NOT INCLUDE MOLD  
PROTRUSION.  
4. MAXIMUM MOLD PROTRUSION 0.15 PER SIDE.  
5. DIMENSION B DOES NOT INCLUDE MOLD  
PROTRUSION. ALLOWABLE DAMBAR  
PROTRUSION SHALL BE 0.127 TOTAL IN EXCESS  
OF THE B DIMENSION AT MAXIMUM MATERIAL  
CONDITION.  
8
1
5
4
M
M
0.25  
B
H
E
h X 45  
MILLIMETERS  
B
e
DIM  
A
A1  
B
C
D
E
e
H
h
MIN  
1.35  
0.10  
0.35  
0.18  
4.80  
3.80  
MAX  
1.75  
0.25  
0.49  
0.25  
5.00  
4.00  
A
C
SEATING  
PLANE  
L
1.27 BSC  
0.10  
5.80  
0.25  
0.40  
0
6.20  
0.50  
1.25  
7
A1  
B
L
M
S
S
0.25  
C
B
A
10  
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
Motorola reserves the right to make changes without further notice to any products herein. Motorola makes no warranty, representation or guarantee regarding  
the suitability of its products for any particular purpose, nor does Motorola assume any liability arising out of the application or use of any product or circuit, and  
specificallydisclaims any and all liability, including without limitation consequential or incidental damages. “Typical” parameters which may be provided in Motorola  
datasheetsand/orspecificationscananddovaryindifferentapplicationsandactualperformancemayvaryovertime. Alloperatingparameters,includingTypicals”  
must be validated for each customer application by customer’s technical experts. Motorola does not convey any license under its patent rights nor the rights of  
others. Motorola products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other  
applicationsintended to support or sustain life, or for any other application in which the failure of the Motorola product could create a situation where personal injury  
ordeathmayoccur. ShouldBuyerpurchaseoruseMotorolaproductsforanysuchunintendedorunauthorizedapplication,BuyershallindemnifyandholdMotorola  
and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees  
arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that  
Motorola was negligent regarding the design or manufacture of the part. Motorola and  
Opportunity/Affirmative Action Employer.  
are registered trademarks of Motorola, Inc. Motorola, Inc. is an Equal  
11  
MOTOROLA ANALOG IC DEVICE DATA  
MC33348  
Mfax is a trademark of Motorola, Inc.  
JAPAN: Motorola Japan Ltd.; SPD, Strategic Planning Office, 141,  
How to reach us:  
USA/EUROPE/Locations Not Listed: Motorola Literature Distribution;  
P.O. Box 5405, Denver, Colorado 80217. 1–303–675–2140 or 1–800–441–2447 4–32–1 Nishi–Gotanda, Shinagawa–ku, Tokyo, Japan. 81–3–5487–8488  
Customer Focus Center: 1–800–521–6274  
Mfax : RMFAX0@email.sps.mot.com – TOUCHTONE 1–602–244–6609  
ASIA/PACIFIC: Motorola Semiconductors H.K. Ltd.; Silicon Harbour Centre,  
Motorola Fax Back System  
– US & Canada ONLY 1–800–774–1848 2, Dai King Street, Tai Po Industrial Estate, Tai Po, N.T., Hong Kong.  
– http://sps.motorola.com/mfax/  
852–26629298  
HOME PAGE: http://motorola.com/sps/  
MC33348/D  

相关型号:

MC33348D-1

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
MOTOROLA

MC33348D-1

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
ONSEMI

MC33348D-1R2

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO8, PLASTIC, SO-8
MOTOROLA

MC33348D-2

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
MOTOROLA

MC33348D-2

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
ONSEMI

MC33348D-2R2

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO8, PLASTIC, SOP-8
ONSEMI

MC33348D-2R2

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO8, PLASTIC, SO-8
MOTOROLA

MC33348D-2R2

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO8, PLASTIC, SOP-8
ROCHESTER

MC33348D-3

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
MOTOROLA

MC33348D-3

LITHIUM BATTERY PROTECTION CIRCUIT FOR ONE CELL SMART BATTERY PACKS
ONSEMI

MC33348D-3R2

1-CHANNEL POWER SUPPLY SUPPORT CKT, PDSO8, PLASTIC, SOP-8
ONSEMI

MC33348D-3R2

Power Supply Support Circuit, Fixed, 1 Channel, PDSO8, PLASTIC, SO-8
MOTOROLA