ZX-XF22 [OMRON]

Smart Sensors (Laser Type) ZX Series (ZX-L-N); 智能传感器(激光型) ZX系列( ZX - L-N )
ZX-XF22
型号: ZX-XF22
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Smart Sensors (Laser Type) ZX Series (ZX-L-N)
智能传感器(激光型) ZX系列( ZX - L-N )

传感器
文件: 总29页 (文件大小:899K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Smart Sensors (Laser Type)  
ZX Series (ZX-L-N)  
.
Ordering Information  
Sensors  
Sensor Heads (Reflective)  
Optical system  
Beam shape  
Sensing distance  
40 10 mm  
Resolution*1  
Model  
Diffuse reflective  
Spot beam  
2 µm  
ZX-LD40  
100 40 mm  
300 200 mm  
40 10 mm  
100 40 mm  
300 200 mm  
30 2 mm  
16 µm  
300 µm  
2 µm  
16 µm  
300 µm  
0.25 µm  
ZX-LD100  
ZX-LD300  
ZX-LD40L  
Line beam  
ZX-LD100L  
ZX-LD300L  
ZX-LD30V  
ZX-LD30VL  
Regular reflective  
Spot beam  
Line beam  
*1. For an average count of 4,096.  
Sensor Heads (Through-beam)  
Optical system  
Measuring width  
Sensing distance  
Resolution*1  
Model  
Through-beam  
1-mm dia.  
0 to 2000 mm  
0 to 500 mm  
4 µm  
ZX-LT001  
ZX-LT005  
ZX-LT010  
ZX-LT030  
5 mm  
10 mm  
30 mm  
12 µm  
*1. For an average count of 64.  
Amplifier Units  
Appearance  
Power supply  
Output type  
Model  
DC  
NPN  
PNP  
ZX-LDA11-N  
ZX-LDA41-N  
Note: Compatible connection with the Sensor Head.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
1
Accessories (Order Separately)  
Calculating Unit  
Setup Tool for Personal Computer  
Appearance  
Model  
Appearance  
Name  
Model  
ZX-CAL2  
Communications Interface  
Unit (RS-232C) + Smart  
Monitor Basic*2 (Function  
Setting Software)  
ZX-SFW11EV3  
(See note 1.)  
+
Note 1. The ZX-SFW11EV3 or ZX-SW11EV3 is required to use the  
Smart Monitor with the ZX-LDA11-N/41-N. Earlier versions  
cannot be used.  
Side-view Attachments  
2. The Smart Monitor Basic does not have a logging function.  
Other than the logging function, the Smart Monitor Basic sup-  
ports the same functions as the Smart Monitor.  
Appearance  
Applicable  
Sensor Head  
Model  
Quantity  
ZX-LT1001/  
LT005  
ZX-XF12  
ZX-XF22  
1
Cables with Connectors on Both Ends (for  
Extension)*1  
ZX-LT010  
Cable length  
Model  
Quantity  
1 m  
4 m  
8 m  
ZX-XC1A  
1
ZX-XC4A  
ZX-XC8A  
ZX-XC9A  
Logging Tool for Personal Computers  
Appearance  
Name  
Model  
9 m *2  
Communica-  
tions Interface  
Unit  
RS-232C  
USB  
ZX-SF11  
*1. Robot Cable models are also available. The model numbers are ZX-XC@R.  
*2. For use only with Reflective Sensors.  
ZX-SF21  
Smart Monitor (Logging Soft- ZX-SW11EV3  
ware + Function Setting Soft- (See note 1.)  
ware)  
2
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Specifications  
Sensor Heads (Reflective)  
Item  
Model ZX-LD40  
ZX-LD100  
ZX-LD300  
ZX-LD30V  
ZX-LD40L ZX-LD100L ZX-LD300L Z3X-LD30VL  
Optical system  
Diffuse reflective  
Regular re- Diffuse reflective  
flective  
Regular reflec-  
tive  
Light source (wave  
length)  
Visible-light semiconductor laser with a wavelength of 650 nm and an output of 1 mW max.  
EN class 2, FDA class II  
Measurement point  
Measurement range  
Beam shape  
40 mm  
10 mm  
Spot  
100 mm  
40 mm  
300 mm  
200 mm  
30 mm  
2 mm  
40 mm  
10 mm  
Line  
100 mm  
40 mm  
300 mm  
200 mm  
30 mm  
2 mm  
Beam size*1  
50-µm dia.  
100-µm dia. 300-µm dia. 75-µm dia.  
75 µm x 2  
150 µm x 2 450 µm x 2 100 µm x 1.8  
mm  
mm  
mm  
mm  
Resolution*2  
Linearity*3  
2 µm  
0.2% FS  
(entire  
range)  
16 µm  
0.2% FS  
(80 to 120  
mm)  
300 µm  
2% FS  
0.25 µm  
0.2% FS  
2 µm  
0.2% FS  
(32 to 48  
mm)  
16 µm  
0.2% FS  
(80 to 120  
mm)  
300 µm  
2% FS  
0.25 µm  
0.2% FS  
(200 to 400 (entire  
(200 to 400 (entire range)  
mm)  
mm)  
range)  
Temperature  
characteristic*4  
0.03% FS/°C (Except for ZX-LD300 and ZX-LD300L, which are 0.1% FS/°C.)  
Ambient illumination  
Ambient temperature  
Ambient humidity  
Incandescent lamp: 3,000 l× max. (on light receiving side)  
Operating: 0 to 50°C, Storage: 15 to 60°C (with no icing or condensation)  
Operating and storage: 35% to 85% (with no condensation)  
20 Mmin. at 500 VDC  
Insulation resistance  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 min  
Vibration resistance  
(destruction)  
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions  
Shock resistance  
(destruction)  
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)  
Degree of protection  
IEC60529, IP50  
IEC60529,  
IP40  
IEC60529, IP50  
IEC60529,  
IP40  
Connection method  
Weight (packed state)  
Connector relay (standard cable length: 500 mm)  
Approx. 150 g  
Approx. 250 Approx. 150 g  
g
Approx. 250 g  
Materials  
Case: PBT (polybutylene terephthalate), Case and  
Case: PBT (polybutylene terephthalate), Case and cov-  
Cover: Aluminum, Lens: Glass  
cover: Alumi- Cover: Aluminum, Lens: Glass  
er: Aluminum,  
Lens: Glass  
num, Lens:  
Glass  
Accessories  
Instruction sheet, Laser warning label (English)  
*1. Beam size: The beam size is defined by 1/e2 (13.5%) of the strength of the beam at the beam center (measured value). Incorrect detection may  
occur if there is light leakage outside the defined spot and the material around the sensing object is more reflective than the sensing object.  
*2. Resolution: The resolution is the deviation ( 3σ) in the linear output when connected to the ZX-LDA Amplifier Unit. (The resolution is measured  
with the standard reference object (white ceramic), at the measurement point with the ZX-LDA set for an average count of 4,096 per period.)  
The resolution is given at the repeat accuracy for a stationary workpiece, and is not an indication of the distance accuracy. The resolution may  
be adversely affected under strong electromagnetic fields.  
*3. Linearity: The linearity is given as the error in an ideal straight line displacement output when measuring the standard reference object. The  
linearity and measurement values vary with the object being measured.  
*4. Temperature characteristic: The temperature characteristic is measured at the measurement point with the Sensor and reference object  
(OMRON’s standard reference object) secured with an aluminum jig.  
Note: Highly reflective objects can result in incorrect detection by causing out-of-range measurements.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
3
Sensor Heads (Through-beam)  
Item  
Model  
ZX-LT001  
Through-beam  
ZX-LT005  
ZX-LT010  
ZX-LT030  
Optical system  
Light source  
(wave length)  
Visible-light semiconductor laser with a wavelength of 650 nm  
EN class 1, FDA class II  
Maximum output  
0.2 mW max.  
1-mm dia.  
0.35 mW max.  
1- to 2.5-mm dia. 5 mm  
0.2 mW max.  
Measurement width  
10 mm  
30 mm  
Measurement  
distance  
0 to 500 mm  
500 to 2,000 mm 0 to 500 mm  
Minimum sensing  
object  
8-µm dia.  
(opaque)  
8- to 50-µm dia. 0.05-mm dia. (opaque)  
(opaque)  
0.1-mm dia. (opaque)  
0.3-mm dia. (opaque)  
Resolution*1  
4 µm *2  
---  
4 µm *3  
12 µm *4  
Temperature  
characteristic  
0.2% FS/°C  
0.3% FS/°C  
Ambient illumination Incandescent lamp: 10,000 l× max. (on light-receiving side)  
Ambient temperature Operating: 0 to 50°C, Storage: 25 to 70°C (with no icing or condensation)  
Ambient humidity Operating: 35% to 85% (with no condensation)  
Degree of protection IEC60529, IP40  
Connection method  
Connector relay (standard cable length: 500 mm)  
Weight (packed state) Approx. 220 g  
Approx. 450 g  
Zinc die-cast  
Cable length  
Materials Case  
Cover  
Extendable up to 10 m with special extension cable.  
Polyetherimide  
Polycarbonate  
Front filter Glass  
Tightening torque  
Accessories  
0.3 Nm max.  
Instruction sheet, Sensor Head-Amplifier Connection Cable  
Optical axis adjustment seal  
Mounting Bracket  
*1. This value is obtained by converting the deviation ( 3σ) in the linear output that results when the sensor head is connected to the amplifier unit,  
into the measurement width.  
*2. For an average count of 64. The value is 5 µm for an average count of 32.  
This is the value that results when a minimum sensing object blocks the light near the center of the 1-mm measurement width.  
*3. For an average count of 64. The value is 5 µm for an average count of 32.  
*4. For an average count of 64. The value is 15 µm for an average count of 32.  
4
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Amplifier Units  
Item  
Model  
ZX-LDA11-N  
ZX-LDA41-N  
Measurement period  
150 µs  
Possible average count settings*1 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096  
Temperature characteristic  
When connected to a Reflective Sensor Head: 0.01% FS/°C, When connected to a Through-beam Sensor  
Head: 0.1% FS/°C  
Linear output*2  
4 to 20 mA/FS, Max. load resistance: 300 Ω, 4 V ( 5 V, 1 to 5 V *3), Output impedance: 100 Ω  
Judgement outputs  
(3 outputs: HIGH/PASS/LOW)*1  
NPN open-collector outputs, 30 VDC, 50 mA max. PNP open-collector outputs, 30 VDC, 50 mA max.  
Residual voltage: 1.2 V max.  
Residual voltage: 2 V max.  
Laser OFF input, zero reset input, ON: Short-circuited with 0-V terminal or 1.5 V or less ON: Supply voltage short-circuited or supply voltage  
timing input, reset input  
OFF: Open (leakage current: 0.1 mA max.)  
within 1.5 V  
OFF: Open (leakage current: 0.1 mA max.)  
Functions  
Measurement value display, present value/set value/light level/resolution display, scaling, display reverse,  
display OFF mode, ECO mode, number of display digit changes, sample hold, peak hold, bottom hold,  
peak-to-peak hold, self-peak hold, self-bottom hold, average hold, delay hold, intensity mode, zero reset,  
initial reset, ON-delay timer, OFF-delay timer, one-shot timer, deviation, previous value comparison,  
sensitivity adjustment, keep/clamp switch, direct threshold value setting, position teaching, 2-point  
teaching, automatic teaching, hysteresis width setting, timing inputs, reset input, monitor focus, linear  
output compensation, (A-B) calculations*4, (A+B) calculations*4, mutual interference*4, laser  
deterioration detection, zero reset memory, zero reset display, key lock  
Indications  
Operation indicators: High (orange), pass (green), low (yellow), 7-segment main display (red), 7-segment  
subdisplay (yellow), laser ON (green), zero reset (green), enable (green)  
Power supply voltage  
Current consumption  
Ambient temperature  
Ambient humidity  
12 to 24 VDC 10%, Ripple (p-p): 10% max.  
140 mA max. with power supply voltage of 24 VDC (with Sensor connected)  
Operating: 0 to 50°C, Storage: 15 to 60°C (with no icing or condensation)  
Operating and storage: 35% to 85% (with no condensation)  
20 Mmin. at 500 VDC  
Insulation resistance  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 min  
Vibration resistance  
(destruction)  
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions  
Shock resistance  
(destruction)  
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)  
Connection method  
Weight (packed state)  
Materials  
Prewired (standard cable length: 2 m)  
Approx. 350 g  
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate  
Instruction sheet  
Accessories  
*1. The response speed of the linear output is calculated as the measurement period × (average count setting + 1) (with fixed sensitivity).  
The response speed of the judgement outputs is calculated as the measurement period × (average count setting + 1) (with fixed sensitivity).  
*2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit.  
*3. Setting is possible via the monitor focus function.  
*4. A Calculating Unit (ZX-CAL2) is required.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
5
Calculating Unit  
Item  
Applicable Amplifier Units  
Current consumption  
Ambient temperature  
Ambient humidity  
ZX-CAL2  
ZX-LDA11-N/41-N/ZX-EDA11/41/ZX-TDA11/41  
12 mA max. (supplied from the Smart Sensor Amplifier Unit)  
Operating: 0 to 50°C, Storage: 15 to 60°C (with no icing or condensation)  
Operating and storage: 35% to 85% (with no condensation)  
Connector  
Connection method  
Dielectric strength  
1,000 VAC, 50/60 Hz for 1 min  
Insulation resistance  
Vibration resistance (destructive)  
Shock resistance (destructive)  
Materials  
100 M(at 500 VDC)  
10 to 150 Hz, 0.7-mm double amplitude 80 min each in X, Y, and Z directions  
300 m/s2 3 times each in six directions (up/down, left/right, forward/backward)  
Display: Acrylic, Case: ABS resin  
Weight (packed state)  
Approx. 50 g  
ZX-series Communications Interface Unit  
Item  
ZX-SF11  
Current consumption  
60 mA max. (supplied by the Amplifier Unit)  
ZX Series  
Applicable Amplifier Units  
Applicable Amplifier Unit versions  
ZX-LDA@1-N Ver. 1.000 or higher  
ZX-EDA@1 Ver. 1.100 or higher  
ZX-TDA@1 Ver. 1.000 or higher  
Max. No. of Amplifier Units  
5
Communications  
functions  
Communications  
port  
RS-232C port (9-pin D-Sub Connector)  
Communications  
protocol  
CompoWay/F*  
38,400 bps  
Baud rate  
Data configuration Data bits: 8, Parity: none, Start bits: 1, Stop bits: 1, Flow control: none  
Indicators  
Power supply: green, Sensor communications: green, Sensor communications error: red, External  
terminal communications: green, External terminal communications error: red  
Protective circuits  
Ambient temperature  
Ambient humidity  
Insulation resistance  
Dielectric strength  
Materials  
Reverse polarity protection  
Operating: 0 to 50°C, storage: 15 to 60°C (with no icing or condensation)  
Operating and storage: 35% to 85% (with no condensation)  
20 Mmin. (at 500 VDC)  
1,000 VAC, 50/60 Hz for 1 min, Leakage current: 10 mA max.  
Case: PBT (polybutylene terephthalate), Cover: Polycarbonate  
Instruction sheet, 2 clamps  
Accessories  
* Contact your OMRON representative for CompoWay/F communications specifications.  
6
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Engineering Data (Typical)  
Angle Characteristic (Reflective Sensors)  
The angle characteristic plots the relation between the inclination of the measurement object and the error in the linear output at the measure-  
ment point.  
Note: SUS304 = Stainless steel SUS304  
ZX-LD100  
Side-to-side Inclination  
4
ZX-LD300  
Side-to-side Inclination  
20  
ZX-LD40  
Side-to-side Inclination  
4
White ceramic  
SUS304  
Black  
paper  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
2
15  
10  
5
3
2
+ inclination  
+ inclination  
inclination  
inclination  
1
1
0
0
0
1  
2  
5  
10  
1  
2  
+ inclination  
inclination  
3  
4  
15  
20  
3  
4  
Angle of inclination (°) 10  
10 8 6 4 2  
0
2
4
6
8
10 8 6 4 2  
0
2
4
6
8
Angle of inclination (°1)0  
10 8 6 4 2  
0
2
4
6
8
10  
Angle of inclination (°)  
Front-to-back Inclination  
Front-to-back Inclination  
Front-to-back Inclination  
4
20  
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
2
15  
10  
5
3
2
+ inclination  
inclination  
1
1
0
0
0
1  
2  
5  
10  
1  
2  
+ inclination  
+ inclination  
3  
4  
15  
20  
3  
4  
inclination  
inclination  
10 8 6 4 2  
0
2
4
6
8
10  
10 8 6 4 2  
0
2
4
6
8
10  
10 8 6 4 2  
0
2
4
6
8
10  
Angle of inclination (°)  
Angle of inclination (°)  
Angle of inclination (°)  
ZX-LD100L  
Side-to-side Inclination  
ZX-LD300L  
Side-to-side Inclination  
ZX-LD40L  
Side-to-side Inclination  
4
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
2
3
2
3
2
+ inclination  
+ inclination  
inclination  
inclination  
1
1
1
0
0
0
1  
2  
1  
2  
1  
2  
+ inclination  
3  
4  
3  
4  
3  
4  
inclination  
10 8 6 4 2  
0
2
4
6
8
10  
10 8 6 4 2  
0
2
4
6
8
10  
10 8 6 4 2  
0
2
6
8
10  
Angle of 4inclination (°)  
Angle of inclination (°)  
Angle of inclination (°)  
Front-to-back Inclination  
Front-to-back Inclination  
Front-to-back Inclination  
20  
4
White ceramic  
SUS304  
Black paper  
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
15  
3
2
3
2
+ inclination  
10  
5
inclination  
1
1
0
0
0
5  
10  
1  
2  
1  
2  
+ inclination  
inclination  
10  
15  
20  
+ inclination  
3  
4  
3  
4  
inclination  
10 8 6 4 2  
0
2
4
6
8
10 8 6 4 2  
0
2
4
6
8
10  
10 8 6 4 2  
0
2
4
6
8
10  
Angle of inclination (°)  
Angle of inclination (°)  
Angle of inclination (°)  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
7
ZX-LD30VL  
Side-to-side Inclination  
ZX-LD30V  
Side-to-side Inclination  
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
3
+ inclination  
2
+ inclination  
2
inclination  
inclination  
1
1
0
1  
2  
0
−1  
−2  
3
−3  
4  
10 8 6 4 2  
4  
0
4
6
8
10  
Angle2of inclination (°)  
10 8 6 4 2  
0
2
4
6
8
10  
Angle of inclination (°)  
Front-to-back Inclination  
Front-to-back Inclination  
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
3
+ inclination  
2
1
2
1
inclination  
0
0
1  
2  
1  
2  
3  
4  
+ inclination  
3  
4  
inclination  
10 8 6 4 2  
10 8 6 4 2  
0
4
6
8
Angle2of inclination (°1)0  
0
2
4
6
8
10  
Angle of inclination (°)  
8
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Linearity Characteristic for Different Materials (Reflective Sensors)  
ZX-LD40  
0° Inclination  
10° Inclination  
4
10° Inclination Front-to-back  
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
3
2
3
2
3
Black paper  
2
0° inclination  
10° inclination  
1
1
1
0
0
1  
2  
0
1  
2  
1  
2  
3  
4  
3  
4  
3  
4 10° inclination  
30 32 34 36 38 40 42 44 46 48 50  
Distance (mm)  
30 32 34 36 38 40 42 44 46 48 50  
Distance (mm)  
30 32 34 36 38 40 42 44 46 48 50  
Distance (mm)  
ZX-LD100  
0° Inclination  
10° Inclination Front-to-back  
10° Inclination  
4
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
3
2
3
2
3
2
10° inclination  
0° inclination  
10° inclination  
1
1
1
0
1  
2  
3  
0
1  
2  
3  
0
1  
2  
3  
4  
4  
4  
60 68 76 84 92 100 108 116 124 132 140  
60 68 76 84 92 100 108 116 124 132 140  
60 68 76 84 92 100 108 116 124 132 140  
Distance (mm)  
Distance (mm)  
Distance (mm)  
ZX-LD300  
0° Inclination  
10° Inclination  
10° Inclination Front-to-back  
5
5
5
White ceramic  
White ceramic  
SUS304  
Black paper  
4
4
3
SUS304  
Black paper  
4
3
3
2
2
2
1
1
1
0
0
0
1  
2  
1  
2  
3  
1  
2  
3  
3  
White ceramic  
SUS304  
Black paper  
4  
5  
4  
5  
4  
5  
10° inclination  
10° inclination  
0° inclination  
100 140 180 220 260 300 340 380 420 460 500  
Distance (mm)  
100 140 180 220 260 300 340  
420 460 500  
Di3s8t0ance (mm)  
100 140 180 220 260 300 340 380 420 460 500  
Distance (mm)  
ZX-LD40L  
0° Inclination  
10° Inclination  
4
10° Inclination Front-to-back  
4
4
White ceramic  
White ceramic  
SUS304  
Black paper  
White ceramic  
SUS304  
Black paper  
SUS304  
Black  
paper  
3
2
3
2
3
2
10° inclination  
0° inclination  
1
1
1
0
0
1  
2  
3  
0
1  
2  
3  
1  
2  
3  
10° inclination  
4  
4  
4  
30 32 34 36 38 40 42 44 46 48 50  
30 32 34 36 38 40 42 44 46 48 50  
30 32 34 36 38 40 42 44 46 48 50  
Distance (mm)  
Distance (mm)  
Distance (mm)  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
9
ZX-LD100L  
0° Inclination  
4
10° Inclination Front-to-back  
10° Inclination  
4
4
White ceramic  
SUS304  
Black paper  
White ceramic  
White ceramic  
SUS304  
Black paper  
SUS304  
Black paper  
3
2
3
2
3
2
0° inclination  
10° inclination  
1
1
10° inclination  
1
0
1  
2  
0
1  
2  
3  
0
1  
2  
3  
4  
3  
4  
4  
60 68 76 84 92 100 108 116 124 132 140  
Distance (mm)  
60 68 76 84 92 100 108 116 124 132 140  
60 68 76 84 92 100 108 116 124 132 140  
Distance (mm)  
Distance (mm)  
ZX-LD300L  
0° Inclination  
10° Inclination  
4
10° Inclination Front-to-back  
4
4
White ceramic  
White ceramic  
SUS304  
Black paper  
3
2
3
2
SUS304  
Black paper  
3
2
10° inclination  
10° inclination  
0° inclination  
1
1
1
0
0
1  
2  
3  
0
1  
2  
3  
1  
2  
White ceramic  
SUS304  
Black paper  
3  
4  
4  
4  
100 140 180 220 260 300 340 380 420 460 500  
100 140 180 220 260 300 340 380 420 460 500  
100 140 180 220 260 300 340 380 420 460 500  
Distance (mm)  
Distance (mm)  
Distance (mm)  
ZX-LD30V  
0° Inclination  
1.0  
10° Inclination  
10° Inclination Front-to-back  
1.0  
1.0  
White ceramic  
White ceramic  
White ceramic  
SUS304  
Black paper  
0.8  
0.6  
SUS304  
Black paper  
0.8  
0.6  
SUS304  
Black paper  
0.8  
0.6  
0.4  
0.4  
0.4  
10° inclination  
10° inclination  
0.2  
0.2  
0.2  
0
0
0
0.2  
0.4  
0.6  
0.2  
0.4  
0.6  
0.2  
0.4  
0.6  
0.8  
1.0  
0.8  
1.0  
0.8  
1.0  
0° inclination  
28.0 28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
28.0 28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
28.0 28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
Distance (mm)  
Distance (mm)  
Distance (mm)  
ZX-LD30VL  
0° Inclination  
10° Inclination  
10° Inclination Front-to-back  
1.0  
1.0  
1.0  
White ceramic  
SUS304  
Black paper  
White ceramic  
White ceramic  
0.8  
0.6  
0.8  
0.6  
SUS304  
Black paper  
0.8  
0.6  
SUS304  
Black paper  
0.4  
0.4  
0.4  
10° inclination  
10° inclination  
0.2  
0.2  
0.2  
0
0
0
0.2  
0.4  
0.6  
0.2  
0.4  
0.6  
0.2  
0.4  
0.6  
0.8  
1.0  
0.8  
1.0  
0.8  
1.0  
0° inclination  
28.0 28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
Distance (mm)  
28.0  
28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
28.0 28.4 28.8 29.2 29.6 30.0 30.4 30.8 31.2 31.6 32.0  
Distance (mm)  
Distance (mm)  
10  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Beam Size  
(Reflective Sensors)  
Spot Beams  
L
Spot Beams  
L
Beam cross-section  
Y
Beam cross-section  
Y
X
X
ZX-LD30V  
L
X
Y
28 mm  
30 mm  
32 mm  
120 µm  
90.0 µm  
ZX-LD40  
60.0 µm  
50.0 µm  
30.0 µm  
40.0 µm  
L
X
Y
30 mm  
240 µm  
350 µm  
40 mm  
50 mm  
250 µm  
370 µm  
40.0 µm  
30.0 µm  
Line Beams  
ZX-LD100  
L
L
60 mm  
100 mm  
140 mm  
X
Y
390 µm  
620 µm  
100 µm  
65.0 µm  
430 µm  
650 µm  
Beam cross-section  
ZX-LD300  
L
Y
100 mm  
300 mm  
500 mm  
X
Y
1,050 µm  
450 µm  
180 µm  
300 µm  
1,100 µm  
850 µm  
X
ZX-LD30VL  
L
X
Y
28 mm  
30 mm  
32 mm  
1,800 µm  
90.0 µm  
1,800 µm  
60.0 µm  
1,800 µm  
110 µm  
Line Beams  
L
Beam cross-section  
Y
X
ZX-LD40L  
L
X
Y
30 mm  
40 mm  
50 mm  
2,000 µm  
240 µm  
2,000 µm  
50.0 µm  
2,000 µm  
250 µm  
ZX-LD100L  
L
60 mm  
100 mm  
140 mm  
X
Y
2,000 µm  
410 µm  
2,000 µm  
100 µm  
2,000 µm  
430 µm  
ZX-LD300L  
L
100 mm  
300 mm  
500 mm  
X
Y
2,000 µm  
750 µm  
2,000 µm  
300 µm  
2,500 µm  
650 µm  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
11  
Sensing Object Characteristics (Through-beam Sensors)  
ZX-LT001  
ZX-LT001  
(For 0.05-mm-dia. pin gauge)  
ZX-LT005  
(For 0.05-mm-dia. pin gauge)  
(For 0.02-mm-dia. pin gauge)  
2
2
1
WD=50 mm  
0
2  
4  
6  
WD=250 mm  
WD=450 mm  
Sensing distance: 500 mm  
Sensing object: 0.05-mm dia.  
0
0.5  
0
2  
4  
6  
0.5  
1  
8  
10  
12  
14  
WD=50 mm  
WD=250 mm  
WD=200 mm  
WD=500 mm  
WD=1,000 mm  
WD=1,500 mm  
8  
WD=450 mm  
10  
Sensing distance: 500 mm  
1.5  
2  
Sensing object: 0.02-mm dia.  
WD=1,800 mm  
12  
Sensing distance: 2 m  
Sensing object: 0.05-mm dia.  
Pin gauge  
Y
Pin gauge  
14  
Y
Pin gauge Y  
16  
18  
2.5  
16  
Emitter side WD  
Receiver side  
1.5 2.5  
Emitter  
Receiver side  
Receiver side  
2.5 5  
WD  
WD  
Emitter side  
2.5  
side  
18  
0
2.5  
1.5  
0.5  
0.5  
3
0
2.5  
1.5  
0.5  
0.5  
1.5  
2.5  
5  
0
Light axis center  
Detection position Y (mm)  
Light axis center  
Detection position Y (mm)  
Light axis center  
Detection position Y (mm)  
ZX-LT010  
(For 0.1-mm-dia. pin gauge)  
1
WD = 50 mm  
WD = 250 mm  
WD = 450 mm  
Sensing distance: 500 mm  
Sensing object: 0.1-mm dia.  
0.5  
0
0.5  
1
1.5  
2
Pin gauge  
WD  
Y
2.5  
3
Receiver  
side  
Emitter side  
8
4
0
4
8
Light axis center  
Detection position Y (mm)  
Linearity Characteristics  
ZX-LT005  
ZX-LT010  
4
4
WD=50 mm  
WD = 50 mm  
WD = 250 mm  
WD = 450 mm  
WD=250 mm  
WD=450 mm  
Sensing distance: 500 mm  
3
3
Sensing distance: 500 mm  
2
2
1
0
1
2
1
0
1  
2  
Emitter  
side  
Receiver  
side  
Receiver  
side  
Emitter side  
WD  
3
4
3  
4  
WD  
0
1
2
3
4
5
0
1
2
3
4
5
Light interruption (mm)  
Light interruption (mm)  
12  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Linear Output vs. Sensing Distance  
The output can be switched between a current output and a voltage output using a switch on the Amplifier Unit.  
ZX-LD40/LD40L  
Current Output  
Voltage Output  
Linear output (V)  
6
Linear output (mA)  
24  
4
20  
2
0
16  
12  
25 30  
35  
40 45  
100 120  
300 400  
50 55  
Distance (mm)  
25 30  
35  
40 45  
50 55  
Distance (mm)  
2  
4  
8
4
6  
0
ZX-LD100/LD100L  
Current Output  
Voltage Output  
Linear output (V)  
6
Linear output (mA)  
24  
4
20  
2
0
16  
12  
40 60  
80  
140 160  
Distance (mm)  
40 60  
80  
100 120  
140 160  
Distance (mm)  
2  
4  
8
4
6  
0
ZX-LD300/LD300L  
Current Output  
Voltage Output  
Linear output (V)  
6
24  
Linear output (mA)  
4
20  
2
0
16  
12  
0
100  
200  
500 600  
Distance (mm)  
0
100  
200  
300 400  
500 600  
Distance (mm)  
2  
4  
8
4
6  
0
ZX-LD30V/LD30VL  
Current Output  
Voltage Output  
Measurement range  
Measurement range  
(4 mm)  
(4 mm)  
6
24  
4
20  
2
0
16  
12  
27  
28  
29  
30 31  
32  
33  
27  
28  
29  
30 31  
32  
33  
Distance (mm)  
Distance (mm)  
2  
4  
8
4
6  
0
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
13  
I/O Circuit Diagrams  
PNP Amplifier Unit: ZX-LDA41-N  
NPN Amplifier Unit: ZX-LDA11-N  
Brown: 12 to 24 VDC  
Brown: 12 to 24 VDC  
White: HIGH  
output  
White: HIGH output  
Green: PASS output  
Gray: LOW output  
Green: PASS output  
Gray: LOW output  
12 to  
24 VDC  
12 to  
24 VDC  
Blue: GND (0V)  
Blue: GND (0V)  
Pink: Laser OFF input  
Purple: Timing input  
Pink: Laser OFF input  
Purple: Timing input  
Orange: Zero reset input  
Red: Reset input  
Orange: Zero reset input  
Red: Reset input  
Current output  
4 to 20 mA  
Current/voltage  
Black: Linear output  
switch  
Current output  
4 to 20 mA  
Voltage output  
4V  
Black: Linear output  
Shield: Linear GND  
Current output: 300 max.  
Voltage output: 10 kmin.  
Current/voltage  
switch  
Current output: 300 max.  
Voltage output: 10 kmin.  
Voltage output  
4V  
Shield: Linear GND  
100 Ω  
100 Ω  
Connections: Amplifier Unit  
Brown:  
12 to 24 VDC  
Blue:  
GND (0V)  
White:  
HIGH output  
Green:  
PASS output  
Gray:  
LOW output  
Black:  
Linear output  
Shield:  
Linear output GND  
Pink:  
Laser OFF input  
Orange:  
Zero reset input  
Purple:  
Timing input  
Red:  
Reset input  
Note 1. Use a separate stabilized power supply for the Amplifier Unit,  
particularly when high resolution is required.  
2. Wire the Unit correctly. Incorrect wiring may result in damage to  
the Unit. (Do not allow wiring, particularly the linear output, to  
come into contact with other lines.)  
3. Use the 0-V line (blue) for the power supply and use the shield  
wire (linear output ground) together with the linear output (black  
line) for linear output. Each of these grounds must be used for  
the designed purpose. When not using the linear output, con-  
nect the linear ground (shield) to the 0-V ground.  
14  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Part Names  
Sensor Heads (Reflective)  
ZX-LD40  
Amplifier Units  
ZX-LDA11-N  
ZX-LDA41-N  
ZX-LD100  
Controls  
ZX-LD300  
ZX-LD40L  
Display area  
ZX-LD100L  
ZX-LD300L  
ZX-LD30V*  
Display area  
Input cable (with connector)  
ZX-LD30VL*  
Receiver  
(Optical filter)  
Output cable  
Connector  
(Cover opens and closes.)  
Output cable (with connector)  
*The dimensions for these models are slightly different. Refer to page 23 for details.  
Sensor Heads (Through-beam)  
ZX-LT001  
Calculating Unit  
ZX-CAL2  
ZX-LT005  
ZX-LT010  
ZX-LT030  
Display area  
Emitter  
Laser ON  
indicator (green)  
Light emitter  
Lit when light is  
emitted.  
Emitter side  
sensor head  
connector  
Emitter  
Connector  
Receiver side  
(Optical filter)  
Receiver side sensor  
head connector  
Receiver  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
15  
Precautions  
Design Precautions  
Other Precautions  
Ratings and Performance  
Environment  
• Conform to the specified ratings and performance. Refer to Speci-  
fications for details.  
1. Do not use the Sensor in strong electromagnetic fields or in an  
environment where the operation of the Sensor is subject to  
the reflection of intense light (such as other laser beams or  
electric arc-welding machines.)  
1. Do not impose voltage exceeding the rated voltage, otherwise  
the Sensor may be damaged.  
2. When supplying power to the Sensor, make sure that the  
polarity of the power is correct, otherwise, the Sensor may be  
damaged. Do not connect to an AC power supply.  
3. Do not short-circuit the load for the open collector output, oth-  
erwise the Sensor may be damaged.  
2. Do not operate the Sensor in the following locations:  
• Locations subject to strong vibration.  
• Locations subject to direct sunlight or near heating equip-  
ment.  
• Locations subject to high humidity.  
• Do not disconnect the connector connecting the Sensor Head and  
the controller while power is being supplied, otherwise the Sensor  
may be damaged.  
• Allow a warm-up period of approximately 10 minutes after turning  
ON the power supply.  
• Locations where the Sensor would accumulate dust, dirt, me-  
tallic powder, etc.  
• Locations subject to corrosive or flammable gases.  
• Locations subject to exposure to organic solvents, water, oil,  
etc.  
• Objects of certain materials or shapes may not be detectable, or the  
detection accuracy may not be sufficiently high. These include ma-  
terials that are transparent or have extremely low reflectivity, and  
objects that are smaller than the Sensor’s spot diameter or have ex-  
treme curvature or inclination.  
• Locations subject to strong electromagnetic or electrical  
fields.  
• Locations subject to rapid changes in temperature.  
• Locations subject to freezing.  
Power Supply and Wiring  
• Prior to turning ON the power supply after wiring is completed,  
check to make sure that the power supply is correct, that there are  
no mistaken connections, e.g., connections that would short-circuit  
the load, and that the load current is appropriate. Incorrect wiring  
may result in damage to the Sensor or Unit.  
• The total length of the Sensor cable or Amplifier cable must be 10 m  
or less. Use an ZX-XC@A Extension Cable (order separately) if re-  
quired to extend the cable from the Sensor. Use a shielded cable to  
extend the Amplifier cable. The shielded cable must be the same as  
that of the Amplifier cable.  
• Do not lay a power supply cable for the ZX together with high-volt-  
age lines or power lines to prevent interference, damage, and mal-  
function.  
• When using a commercially available switching regulator, ground  
the FG (frame ground) terminal.  
• If the power supply line is subject to surges, connect a surge ab-  
sorber that meets the conditions of the usage environment.  
• When using a Calculating Unit, connect the corresponding linear  
ground of the Amplifier Unit.  
Compatibility  
• All Sensor Heads and Amplifier Units are compatible. Different Sen-  
sor Heads may be purchased at a later date and used with existing  
Amplifier Units.  
Mutual Interference  
• Two Sensor Heads can be used together, without danger of mutual  
interference, by connecting the ZX-CAL 2 Calculating Unit between  
two Amplifier Units.  
Maintenance  
• Always turn OFF the power supply before adjusting or removing the  
Sensor Head.  
• Cleaning  
Do not use thinners, benzine, acetone, or kerosene for cleaning.  
If dust or oil adheres to the filter on the front of the Sensor Head,  
use the following procedure to clean.  
1. Use a blower brush (used to clean camera lenses) to blow  
large dust particles from the surface. Do not blow the dust  
away with your mouth.  
2. Use a soft cloth (for lenses) with a small amount of alcohol to  
remove the remaining dust. Do not use a scrubbing action  
when cleaning because scratches on the filter could result in  
Sensor inaccuracy.  
16  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Laser Safety  
The ZX-LD-Series Sensor Heads are FDA Class II and EN Class 2 Laser Products. The ZX-LT-Series Sensor Heads are FDA Class II and EN  
Class 1 Laser Products. The ZX Series is meant to be built into final system equipment. Pay special attention to the following precautions for the  
safe use of the product:  
Note: Europe: Class 1 and Class 2 of EN60825-1: 1994 = IEC825-1: 1993  
U.S.A.: Class I and Class II of FDA (21 CFR1040.10)  
1. Use this product as specified in this instruction manual. Otherwise, you may be exposed to hazardous laser radiation.  
2. The ZX-series Smart Sensors radiate laser beams in the visible light range. Do not expose your eyes directly to the laser radiation. Ensure  
that the laser beam path is terminated during use. If a mirror or shiny surface is positioned in the laser beam path, ensure that the reflected  
beam path is also terminated. If the Unit must be used without terminating the laser beam path, position the laser beam path so that it is not  
at eye level.  
3. To avoid exposure to hazardous laser radiation, do not displace nor remove the protective housing during operation, maintenance, and any  
other servicing.  
4. The user should return the product to OMRON for all repair and servicing.  
5. As for other countries, observe the regulations and standards specified by each country.  
Requirements from Regulations and Standards  
EN60825-1 “Safety of Laser Products, Equipment Classification, Requirements and User’s  
Guide”  
Summary of Manufacturer’s Requirements  
Requirements;  
Sub-clause  
Classification  
Class 3A  
Class 1  
Class 2  
Class 3B*  
Class 4  
Description of hazard  
class  
Safe under reason-  
ably foreseeable con- tection normally af-  
ditions  
Low power; eye pro- Same as Class 2. Di- Direct intrabeam view- High power; diffused  
rect intrabeam view- ing may be hazardous reflection may be haz-  
forded by aversion  
responses  
ing with optical aids  
may be hazardous  
ardous  
Protective housing  
Required for each laser product; limits access necessary for performance of functions of the products  
Safety interlock in pro-  
tective housing  
Designed to prevent removal of the panel until accessible emission values are below the AEL (see note 2) for the class  
assigned  
Remote control  
Not required  
Permits easy addition of external interlock in la-  
ser installation  
Key control  
Not required  
Not required  
Laser inoperative when key is removed  
Emission warning de-  
vice  
Gives audible or visible warning when laser is  
switched on or if capacitor bank of pulsed laser  
is being charged  
Attenuator  
Not required  
Not required  
Gives means beside ON/OFF switch to tempo-  
rarily block beam  
Location controls  
Controls so located that there is no danger of exposure to AEL above  
Classes 1 or 2 when adjustments are made.  
Viewing optics  
Scanning  
Emission from all viewing systems must be below Class 1 AEL’s as applicable  
Scan failure shall not cause product to exceed its classification  
Class label  
Required wording  
Not required  
Figures A and B and specified wording  
Aperture label  
Service entry label  
Specified wording required  
Required as appropriate to the class of accessible radiation  
Override interlock label Required under certain conditions as appropriate to the class of laser used  
User information Operation manuals must contain instructions for safe use  
Purchasing and service Promotion brochures must reproduce classification labels; service manuals must contain safety information  
information  
Medical products  
Special calibration instructions required  
Special calibration instructions, means for  
measurement and target-indicator required  
Fibre optic  
Cable service connections require tool to disconnect if disconnection breaks protective housing and permits access  
above Class 1  
*With respect to the requirements of remote interlock connector, key control, emission warning and attenuator, Class 3B laser products not  
exceeding five times the AEL of Class 2 in the wavelength range of 400 nm to 700 nm are to be treated as Class 3A laser products.  
Note 1. This table is intended to provide a convenient summary of requirements. See text of this standard for complete requirements.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
17  
2. AEL: Accessible Emission Limit  
The maximum accessible emission level permitted within a particular class.  
For your reference, see ANSI Z136.1-1993, Section 2.  
Symbol and border: black  
Background: yellow  
Figure A Warning label - Hazard symbol  
Legend and border: black  
Background: yellow  
Figure B Explanatory label  
18  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
FDA (Compliance Guide for Laser Products, 1985, according to 21 CFR1040.10)  
Requirements  
Class (see note 1)  
II IIIa  
I
IIa  
IIIb  
IV  
Performance (all laser products)  
Protective housing  
R
R
R
R
R
R
(see note 2)  
(see note 2)  
(see note 2)  
(see note 2)  
(see note 2)  
(see note 2)  
Safety interlock  
R (see notes 3, 4) R (see notes 3, 4) R (see notes 3, 4) R (see notes 3, 4) R (see notes 3, 4) R (see notes 3, 4)  
Location of controls  
Viewing optics  
N/A  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Scanning safeguard  
R
Performance (laser systems)  
Remote control connector N/A  
N/A  
N/A  
N/A  
N/A  
N/A  
R
N/A  
N/A  
R
R
R
R
R
Key control  
N/A  
N/A  
Emission indicator  
R
R
(see note 10)  
(see note 10)  
Beam attenuator  
Reset  
N/A  
N/A  
N/A  
N/A  
R
R
R
R
N/A  
N/A  
N/A  
R
(see note 13)  
Performance (specific purpose products)  
Medical  
S
S
S
S
S
S
S
S
S
S
S
S
(see note 8)  
(see note 8)  
(see note 8)  
Surveying, leveling, align-  
ment  
S
NP  
NP  
Demonstration  
S
S
S
(see note 11)  
(see note 11)  
Labeling (all laser products)  
Certification & identifica-  
tion  
R
R
R
R
R
R
Protective housing  
D
D
D
D
D
D
(see note 5)  
(see note 5)  
(see note 5)  
(see note 5)  
(see note 5)  
(see note 5)  
Aperture  
N/A  
N/A  
N/A  
R
R
R
R
Class warning  
R
R
R
R
R
(see note 6)  
(see note 7)  
(see note 9)  
(see note 12)  
(see note 12)  
Information (all laser products)  
User information  
Product literature  
Service information  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
N/A  
R
Abbreviations:  
R: Required.  
N/A: Not applicable.  
S: Requirements: Same as for other products of that Class.  
Also see footnotes.  
NP: Not permitted.  
D: Depends on level of interior radiation.  
Footnotes:  
1. Based on highest level accessible during operation.  
2. Required wherever & whenever human access to laser radiation above Class I limits is not needed for product to perform its function.  
3. Required for protective housings opened during operation or maintenance, if human access thus gained is not always necessary when  
housing is open.  
4. Interlock requirements vary according to Class of internal radiation.  
5. Wording depends on level & wavelength of laser radiation within protective housing.  
6. Warning statement label.  
7. CAUTION logotype.  
8. Requires means to measure level of laser radiation intended to irradiate the body.  
9. CAUTION if 2.5 mW cm2 or less, DANGER if greater than 2.5 mW cm2.  
10.Delay required between indication & emission.  
11.Variance required for Class IIb or iV demonstration laser products and light shows.  
12.DANGER logotype.  
13.Required after August 20, 1986.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
19  
Use Precautions  
EN60825-1  
Requirements;  
Sub-clause  
Classification  
Class 3A  
Class 1  
Not required  
Class 2  
Class 3B*  
Class 4  
Remote interlock  
Key control  
Connect to room or door circuits  
Remove key when not in use  
Not required  
Not required  
Beam attenuator  
When in use prevents inadvertent exposure  
Indicates laser is energized  
Emission indicator de- Not required  
vice  
Warning signs  
Beam path  
Not required  
Follow precautions on warning signs  
Not required  
Terminate beam at end of useful length  
Specular reflection  
Eye protection  
No requirements  
No requirements  
Prevent unintentional reflections  
Required if engineering and administrative procedures not practicable  
and MPE exceeded  
Protective clothing  
Training  
No requirements  
No requirements  
Sometimes required  
Specific requirements  
Required for all operator and maintenance personnel  
*With respect to the requirements of remote interlock connector, key control, beam attenuator, and emission indicator, Class 3B laser products not  
exceeding five times the AEL of Class 2 in the wavelength range of 400 nm to 700 nm are to be treated as Class 3A laser products.  
Note: This table is intended to provide a convenient summary of requirements. See text of this standard for complete precautions.  
ANSI Z136.1:1993 “American National Standard for the Safe Use of Lasers”  
Control Measures for the Four Laser Classes  
Control measures  
Engineering Controls  
Classification  
1
2a  
X
2
3a  
X
3b  
X
4
Protective Housing (4.3.1)  
X
X
X
Without Protective Housing (4.3.1.1)  
Interlocks on Protective Housing (4.3.2)  
Service Access Panel (4.3.3)  
Key Control (4.3.4)  
LSO (see note 2) shall establish Alternate Controls  
X
X
X
X
---  
---  
---  
---  
X
Viewing Portals (4.3.5.1)  
---  
---  
MPE  
MPE  
---  
MPE  
MPE  
---  
MPE  
MPE  
MPE  
MPE  
Collecting Optics (4.3.5.2)  
MPE  
---  
MPE  
---  
Totally Open Beam Path (4.3.6.1)  
X
X
NHZ  
NHZ  
Limited Open Beam Path (4.3.6.2)  
---  
---  
---  
---  
X
NHZ  
X
NHZ  
Enclosed Beam Path (4.3.6.3)  
Remote Interlock Connector (4.3.7)  
Beam Stop or Attenuator (4.3.8)  
Activation Warning Systems (4.3.9)  
Emission Delay (4.3.9.1)  
None is required if 4.3.1 and 4.3.2 fulfilled  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
X
X
X
X
---  
Indoor Laser Controlled Area (4.3.10)  
X
X
NHZ  
NHZ  
Class 3b Laser Controlled Area (4.3.10.1)  
Class 4 Laser Controlled Area (4.3.10.2)  
Laser Outdoor Controls (4.3.11)  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
---  
X
---  
X
---  
X
NHZ  
X
NHZ  
Laser in Navigable Airspace (4.3.11.2)  
Temporary Laser Controlled Area (4.3.12)  
---  
---  
---  
MPE  
MPE  
MPE  
MPE  
---  
---  
Remote Firing & Monitoring (4.3.13)  
Labels (4.3.14 and 4.7)  
---  
X
---  
X
---  
X
---  
X
---  
X
X
Area Posting (4.3.15)  
---  
---  
---  
X
X
NHZ  
NHZ  
Administrative & Procedural Controls  
Standard Operating Procedures (4.4.1)  
Output Emission Limitations (4.4.2)  
Education and Training (4.4.3)  
Authorized Personnel (4.4.4)  
1
2a  
---  
---  
---  
---  
---  
2
3a  
---  
3b  
4
---  
---  
---  
---  
---  
---  
---  
X
LSO Determination  
X
X
X
X
X
X
---  
X
---  
X
Alignment Procedures (4.4.5)  
20  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Control measures  
Protective Equipment (4.4.6)  
Classification  
---  
---  
---  
---  
---  
---  
---  
---  
X
X
X
Spectator (4.4.7)  
Service Personnel (4.4.8)  
X
MPE  
MPE  
MPE  
MPE  
Demonstration with General Public (4.5.1)  
Laser Optical Fiber Systems (4.5.2)  
Laser Robotic Installations (4.5.3)  
MPE  
MPE  
---  
---  
X
X
X
X
X
X
MPE  
---  
MPE  
---  
MPE  
---  
X
NHZ  
X
NHZ  
Eye Protection (4.6.2)  
---  
---  
---  
---  
---  
---  
---  
---  
X
MPE  
MPE  
Protective Windows (4.6.3)  
X
X
NHZ  
NHZ  
Protective Barriers and Curtains (4.6.4)  
Skin Protection (4.6.5)  
---  
---  
---  
---  
---  
---  
---  
---  
X
MPE  
X
MPE  
Other Protective Equipment (4.6.5)  
Use may be required  
---  
Warning Signs and Labels (4.7) (Design Requirements) ---  
X
NHZ  
X
NHZ  
Service and Repairs (4.8)  
LSO Determination  
LSO Determination  
Modification of Laser Systems (4.9)  
Note 1. LEGEND  
X:  
•:  
---:  
:  
Shall  
Should  
No requirement  
Shall if enclosed Class 3b or Class 4  
MPE: Shall if MPE is exceeded  
NHZ: Nominal Hazard Zone analysis required  
:  
Applicable only to UV and IR Lasers (4.5.1.2)  
2. LSO: Laser Safety Officer  
An individual shall be designated the Laser Safety Officer with the authority and responsibility to monitor and enforce the control of laser  
hazards, and to effect the knowledgeable evaluation and control of laser hazards.  
For your reference, see ANSI Z136.1-1993, Section 1.3.  
Laser Product Classifications  
EN  
Class  
Description  
Class 1  
Class 2  
Lasers which are safe under reasonably foreseeable conditions of operation.  
Lasers emitting visible radiation in the wavelength range from 400 nm to 700 nm. Eye protection is normally afforded by  
aversion responses including the blink reflex.  
Class 3A  
Lasers which are safe for viewing with the unaided eye. For laser emitting in the wavelength range from 400 nm to 700 nm,  
protection is afforded by aversion responses including the blink reflex. For other wavelengths the hazard to the unaided  
eye is no greater than for Class 1. Direct intrabeam viewing of Class 3A lasers with optical aides (e.g., binoculars, tele-  
scopes, microscopes) may be hazardous.  
Class 3B  
Class 4  
Direct intrabeam viewing of these lasers is always hazardous. Viewing diffuse reflections is normally safe (see note).  
Lasers which are also capable of producing hazardous diffuse reflections. They may cause skin injuries and could also  
constitute a fire hazard. Their use requires extreme caution.  
Note: Conditions for safe viewing of diffuse reflections for Class 3B visible lasers are: minimum viewing distance of 13 cm between screen and  
cornea and a maximum viewing time of 10 s. Other viewing conditions require a comparison of the diffuse reflection exposure with the MPE.  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
21  
Comparison of Classifications between FDA and ANSI  
Class  
Class I/1  
FDA definition  
ANSI description  
Limits applicable to devices that have emissions in the ultraviolet, visi- A Class 1 laser is considered to be incapable of pro-  
ble, and infrared spectra, and limits below which biological hazards  
have not been established.  
ducing damaging radiation levels during operation and  
maintenance and is, therefore, exempt from any con-  
trol measures or other forms of surveillance.  
Class IIa/2a  
Class II/2  
Limits applicable to products whose visible emission does not exceed Class 2 lasers are divided into two subclasses, 2 and  
Class I limits for emission durations of 1,000 seconds or less and are  
not intended for viewing.  
2a. A Class 2 laser emits in the visible portion of the  
spectrum (0.4 to 0.7 µm) and eye protection is normal-  
ly afforded by the aversion response including the blink  
reflex.  
Limits applicable to products that have emissions in the visible spectrum  
(400 to 710 nm) for emission durations in excess of 0.25 second, pro-  
viding that emissions for other durations and/or wavelengths do not ex-  
ceed the Class I limits. Class II products are considered hazardous for  
direct long-term ocular exposure.  
Class IIIa/3a  
Class IIIb/3b  
Limits to products that have emissions in the visible spectrum and that Class 3 lasers are divided into two subclasses, 3a and  
have beams where the total collectable radiant power does not exceed 3b. A Class 3 laser may be hazardous under direct and  
5 milliwatts.  
specular reflection viewing conditions, but the diffuse  
reflection is usually not a hazard.  
Limits applicable to devices that emit in the ultraviolet, visible, and infra-  
red spectra. Class IIIb products include laser systems ranging from 5 to  
500 milliwatts in the visible spectrum. Class IIIb emission levels are oc-  
ular hazards for direct exposure throughout the range of the Class, and  
skin hazards at the higher levels of the Class.  
Class IV/4  
Exceeding the limits of Class IIIb and are a hazard for scattered reflec- A Class 4 laser is a hazard to the eye or skin from the  
tion as well as for direct exposure.  
direct beam and sometimes from a diffuse reflection  
and also can be a fire hazard. Class 4 lasers may also  
produce laser-generated air contaminants and hazard-  
ous plasma radiation.  
Label Indications  
EN  
EN/IEC warning label  
Laser warning label  
Explanatory label with specified wording  
Note: Use of controls, adjustments, or procedures other than those specified herein may result in hazardous radiation exposure.  
FDA  
Aperture Label  
Class II Caution logo type  
Certification and  
identification label  
Caution  
logo type  
Aperture label  
Certification and Identification Label  
Note: Use of controls, adjustments, or procedures other than those specified herein may result in hazardous radiation exposure.  
22  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
Dimensions  
(Unit: mm)  
Sensor Heads (Diffuse Reflective)  
ZX-LD40  
ZX-LD100  
ZX-LD300  
ZX-LD40L  
ZX-LD100L  
ZX-LD300L  
17  
16.6  
12.4  
Two 3.2-dia. mounting  
holes  
Mounting Holes  
Two, M3 holes  
L ∗  
33  
7
Measurement  
point  
1.8  
3.5  
Reference  
surface  
5
7
14.8  
3.4  
A ∗  
Emitter axis  
Lens: 5 dia.  
30.05  
32  
31.1  
0.1  
32  
Receiver axis  
Range  
indicators  
39  
7
Lens: 8 dia.  
0.1  
3.5  
7
26  
24.05  
26  
Connector  
15 dia.  
46  
Vinyl-insulated round cable, 5.1 dia.,  
Standard: 500 mm  
ZX-LD40L: L = 40 mm, A = 23°  
ZX-LD10L: L = 100 mm, A = 11°  
ZX-LD30L: L = 300 mm, A = 3.8°  
Sensor Heads (Regular Reflective)  
14  
ZX-LD30V  
4.8  
ZX-LD30VL  
25 8.6  
Vinyl-insulated round cable,  
5.1 dia., Standard: 0.5 m  
5-R2  
20.7  
42.7  
Connector  
Mounting Holes  
45  
1
1
32.7  
30  
Two, M4 holes  
4.75  
4.75  
46  
9.5  
9.2  
0.1  
47  
35°  
12.5  
Light axis  
Two, 4.5-dia.  
15 dia.  
mounting holes  
Emitter  
axis  
Receiver  
axis  
47  
55  
Reference plain  
Measurement center  
Lens (10 dia.)  
Lens (16 dia.)  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
23  
Sensor Heads (Through-beam)  
ZX-LT001  
ZX-LT005  
Emitter  
Receiver  
Two, 3.2 dia.  
34  
Two, 3.2 dia.  
19 2.8  
Vinyl-insulated round  
cable (gray), 2.6 dia.,  
Standard: 500 mm  
2.8  
Vinyl-insulated round cable (black),  
2.6 dia., Standard: 500 mm  
5
16  
9
15  
15  
9
Connector  
Connector  
Laser ON indicator  
Light axis center  
15  
Light axis center  
15  
Slit (1 x 5) (Only for ZX-LT005)  
Mounting Holes  
Mounting Holes  
0.1  
0.1  
9
9
Two, M3 holes  
Two, M3 holes  
Sensor Head-Amplifier Unit  
Connecting Cable (Provided)  
1,500+200  
0
46  
15 dia.  
Connector  
Connector  
2.6 dia × 2  
Receiver  
Two, 3.2 dia.  
Emitter  
ZX-LT010  
Two, 3.2 dia.  
Vinyl-insulated round  
cable (gray), 2.6 dia.,  
Standard: 500 mm  
2.8  
42  
22  
25  
2.8  
Vinyl-insulated round cable (black),  
2.6 dia., Standard: 500 mm  
10  
14 20  
20 14  
Connector  
Connector  
Light axis center  
Laser ON indicator  
Light axis center  
20  
20  
Slit (1 x 10)  
Mounting Holes  
Mounting Holes  
14 0.1  
14 0.1  
Two, M3 holes  
Two, M3 holes  
Sensor Head-Amplifier Unit  
Connecting Cable (Provided)  
1,500+200  
0
46  
15 dia.  
Connector  
Connector  
2.6 dia × 2  
24  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
ZX-LT030  
Receiver  
Emitter  
70  
50  
70  
50  
Two, 4.5 dia.  
Two, 4.5 dia.  
10  
10  
16  
16  
10  
10  
22.6  
22.6  
Vinyl insulated  
round cable, 4 dia.,  
Standard length: 0.5 m  
Vinyl insulated round  
cable, 4 dia.,  
Standard length: 0.5 m  
68  
1
1
52  
Three, M4 x 25  
+ pan head screw  
Three, M4 x 25  
+ pan head screw  
44  
44  
70  
70  
69  
69  
41  
41  
4.75  
4.75  
21  
21  
12.5  
12.5  
9
9
10  
5
44  
60  
10  
2.3  
5
2.3  
Connector  
Connector  
Lens (8 x 36)  
10  
9.5  
Slit (1 x 30)  
Two, M3,  
Two, M3, depth: 5  
35.9  
18  
depth: 5  
35  
43  
6
6
8.1  
8.1  
20  
20  
Two, M4  
Two, M4  
11.5 dia.  
14.7 dia.  
50  
50  
Sensor Head - Amplifier Unit  
Connection Cable  
35.3  
1500+50  
0
46  
11 dia.  
15 dia.  
43  
13.2 dia.  
Amplifier Units  
ZX-LDA11-N  
ZX-LDA41-N  
133  
44  
4.2  
3
64.3  
4.2  
30  
31.5  
15.8  
15.5 dia.  
13.2  
13  
36.8  
Vinyl-insulated round cable, 5.23 dia.  
Standard: 100 mm  
Vinyl-insulated round cable, 5.2 dia. (conductor  
cross-section: 0.09 mm2, 10-conductor insulator  
diameter: 0.7 mm), Standard: 2 m  
11.7  
11.7  
2.2  
29  
Current/voltage output selector switch  
(set to voltage output when shipped)  
Voltage output  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
25  
Accessories (Order Separately)  
Operation  
indicators  
Calculating Unit  
Connectors  
24.9  
19.5  
ZX-CAL2  
3
57  
15.1  
12  
8
54.9  
44.05  
9.5  
30  
15  
26  
14.4  
5
36.7  
3.4  
Side-view Attachments  
ZX-XF12  
15  
Light axis center  
Two, 2.2 dia.  
15 10.6  
15  
15  
2.7  
ZX-XF22  
20  
Light axis center  
Two, 2.2 dia.  
20  
21  
Seal  
20  
2.8  
26  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
ZX-series Communications Interface Unit  
ZX-SF11  
Coupling connector  
Sensor communications indicator (communications operation)  
Sensor communications indicator (communications error)  
External terminal communications  
indicator (communications operation)  
Power supply indicator  
External terminal communications  
indicator (communications error)  
4.2  
64.3  
4.2  
30  
3
(336)  
(46)  
31.5  
15  
13  
36.8  
13.2  
Vinyl-insulated round cable, 5.23 dia.  
Standard: 100 mm  
11.7  
(33.1)  
11.7  
3
5
6.55  
Connector  
Cables with Connectors on Both  
Ends (for Extension)  
46  
44  
ZX-XC1A (1 m)  
ZX-XC4A (4 m)  
15.5 dia.  
15 dia.  
ZX-XC8A (8 m)  
ZX-XC9A (9 m)  
Vinyl-insulated round cable, 5.2 dia.,  
10 conductors  
12 pins (male)  
12 pins (female)  
ZX-XC1A: 1,000  
ZX-XC4A: 4,000  
ZX-XC8A: 8,000  
ZX-XC9A: 9,000  
ZX Series (ZX-L-N) Smart Sensors (Laser Type)  
27  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
This document provides information mainly for selecting suitable models. Please read the document Z197 carefully for  
information that the user must understand and accept before purchase, including information on warranty, limitations of  
liability, and precautions.  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
Sensing Devices Division H.Q.  
Application Sensors Division  
Shiokoji Horikawa, Shimogyo-ku,  
Kyoto, 600-8530 Japan  
Tel: (81)75-344-7068/Fax: (81)75-344-7107  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if  
specied) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE  
HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL  
OTHER WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL  
LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR  
STRICT LIABILITY.  
In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the product.  
At the customer's request, OMRON will provide applicable third party certication documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufcient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
• Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
• Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government regulations.  
• Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when signicant construction changes are made.  
However, some specications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to x  
or establish key specications for your application on your request. Please consult with your OMRON representative at any time to conrm actual  
specications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
ERRORS AND OMISSIONS  
The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent  
the result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
COPYRIGHT AND COPY PERMISSION  
This catalog shall not be copied for sales or promotions without permission.  
This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this  
catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety.  
2008.4  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2008 All Rights Reserved.  

相关型号:

ZX05-1

Level 7 (LO Power +7 dBm) 0.5 to 500 MHz
MINI

ZX05-1+

Level 7 (LO Power +7 dBm) 0.5 to 500 MHz
MINI

ZX05-1-S

Level 7 (LO Power +7 dBm) 0.5 to 500 MHz
MINI

ZX05-1-S+

Double Balanced Mixer, 0.5MHz Min, 500MHz Max, 7.8dB Conversion Loss-Max, ROHS COMPLIANT, CASE FL905
MINI

ZX05-10

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 8.3dB Conversion Loss-Max, CASE FL905
MINI

ZX05-10+

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 8.3dB Conversion Loss-Max, ROHS COMPLIANT, CASE FL905
MINI

ZX05-10-S

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 8.3dB Conversion Loss-Max, CASE FL905
MINI

ZX05-10-S+

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 8.3dB Conversion Loss-Max, ROHS COMPLIANT, CASE FL905
MINI

ZX05-10H

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 9.5dB Conversion Loss-Max, CASE FL905
MINI

ZX05-10H-S

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 9.5dB Conversion Loss-Max, CASE FL905
MINI

ZX05-10H-S+

Double Balanced Mixer, 10MHz Min, 1000MHz Max, 9.5dB Conversion Loss-Max, ROHS COMPLIANT, CASE FL905
MINI

ZX05-10L

Frequency Mixer
MINI