VX-52-1A3 [OMRON]
Snap Action Switch; 速动开关型号: | VX-52-1A3 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Snap Action Switch |
文件: | 总8页 (文件大小:677K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
VSnaXp Action Switch
Miniature Snap Action Switch
• Compact snap action switch with low force operation
• Wide variation extends from microload to 5 A switching
current, with shapes identical to those of the V-series
Miniature Basic Snap Action Switch.
• Internal hinge lever mechanism assures outstanding con-
tact reliability
• RoHS Compliant
Ordering Information
Actuator
Terminal Style
OF max.
25 gf
Rated current
5 A
0.1 A
Pin plunger
VX-5-1A2
VX-01-1A2
VX-01-1A3
A
VX-5-1A3
50 gf
25 gf
50 gf
VX-5-1C22
VX-5-1C23
VX-51-1A3
VX-51-1C23
VX-52-1A3
VX-52-1C23
VX-53-1A3
VX-53-1C23
VX-01-1C22
VX-01-1C23
VX-011-1A3
VX-011-1C23
VX-012-1A3
VX-012-1C23
VX-013-1A3
VX-013-1C23
C2
Short hinge lever
Hinge lever
A
50 gf
30 gf
20 gf
C2
A
C2
A
Long hinge lever
C2
A
Simulated roller lever
VX-54-1A3
VX-014-1A3
30 gf
60 gf
VX-54-1C23
VX-014-1C23
C2
A
Short hinge roller lever
Hinge roller lever
VX-55-1A3
VX-55-1C23
VX-56-1A3
VX-56-1C23
VX-015-1A3
VX-015-1C23
VX-016-1A3
VX-016-1C23
C2
A
30 gf
C2
Model Number Legend
VX -
-
1 2 3 4 5
2. Actuator
None: Pin plunger
3. Contact Form
5. Maximum Operating Force
1. Ratings
1:
2:
3:
SPDT
SPST-NC
SPST-NO
2:
3:
25 gf
50 gf
5:
5 A at 250 VAC
0.1 A at 30 VDC
01:
1:
2:
3:
4:
5:
6:
Short hinge lever
Hinge lever
Long hinge lever
Simulated roller lever
Short hinge roller lever
Hinge roller lever
Note: These OF values are for
the pin plunger models.
4. Terminals
A:
C2:
Solder terminals
Quick-connect terminals (#187)
Snap Action Switch VX
135
Specifications
■ Characteristics
Item
Operating speed
VX-5
VX-01
0.1 mm to 1 m/s (pin plunger models)
Operating frequency
Mechanical: 600 operations per minute
Electrical: 30 operations per minute
Contact resistance
30 mΩ max.
50 mΩ max.
Insulation resistance
100 MΩ min. at 500 VDC
Dielectric strength (see note 2)
1,000 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground and
between each terminal and non-current-carrying metal parts
Vibration resistance (see note 3)
Shock resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Destruction: 400 m/s2 (approx. 40G) max.
Malfunction: 100 m/s2 (approx. 10G) max
Degree of protection
IEC IP40
Degree of protection against electric shock
Proof tracking index
Class I
175
Ambient operating temperature
Ambient operating humidity
-25°C to 80°C (at 60% RH max.) with no icing
85% max (for 5°C to 35°C)
Service life
Mechanical 50,000,000 operations min. (60 ops/minute) 10,000,000 operations min. (60 ops/minute)
Electrical
500,000 operations min. (30 ops/minute)
Approx. 6.2 g (pin plunger models)
1,000,000 operations min. (30 ops/minute)
Weight
Note: 1. Data shown are of initial value.
2. The dielectric strength shown is measured using a separator between the switch and metal mounting plate.
3. For the pin plunger models, the above values apply for use at the free position and total travel position. For lever models, they apply at
the total travel position. Contact separation time is within 1 ms.
■ Ratings (reference values)
Resistive load
Lamp load
Inductive load
NC NO
Type
Rated voltage
250 VAC
125 VAC
8 VDC
NC NO
NC
NO
5 A
5
5
- - -
0.5
3
- - -
4
4
5
30 VDC
5
3
4
125 VDC
250 VDC
125 VAC
8 VDC
0.4
0.3
0.1
0.1
0.1
0.1
0.05
- - -
- - -
- - -
0.4
0.2
- - -
- - -
- - -
0.1 A
30 VDC
Note: 1. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 milliseconds max. (DC).
2. Lamp load has an inrush current of 10 times the steady-state current
3. The electrical rating applies under the following test conditions:
Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/minute
■ Approved Standards
■ Contact Specifications
UL Recognized (File No. E41515)
CSA Certified (File No. LR21642)
Item
VX-5
VX-01
Crossbar
Gold alloy
Specification
Rivet
Rated Voltage
125 VAC
VX-5
5 A
VX-01
0.1 A
- - -
Material
Silver alloy
Gap (standard value)
Inrush current
0.5 mm
NC: 15A max.
250 VAC
5 A
- - -
NO:
- - -
30 VDC
- - -
0.1 A
Minimum applicable load
(see note)
160 mA at 5 VDC 1 mA at 5 VDC
EN61058-1 - - VDE approval (File No. 124761)
Rated Voltage
125 VAC
VX-5
5 A
VX-01
0.1 A
- - -
Note: Minimum applicable loads are indicated by N standard refer-
ence values. This value represents the failure rate at a 60%
(λ60) reliability level (JIS C5003).
250 VAC
5 A
-6
The equation λ60=0.5 x 10 / operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%
Testing conditions: 5E4 (50,000 operations), T105 (0°C to 105°C)
136
Snap Action Switch VX
Engineering Data
■ Mechanical service life
VX-01
VX-5
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Without load
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Without load
200
100
200
Operating frequency: 600 operations/min
Operating frequency: 600 operations/min
100
50
50
Full stroke
Rated value
of OT
10
10
Full stroke
Rated value
of OT
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 (1.6) 1.8
0
0.2 0.4 0.6 0.8 1.0 1.2 1.4 (1.6) 1.8
Overtravel (mm)
Overtravel (mm)
■ Electrical service life
VX-5
VX-01
5
Ambient temperature: 20 2°C
Ambient humidity: 65 5%
Without load
Operating frequency: 60 operations/min
cosφ = 1, 250 VAC
2
1
10
5
0.5
0.3
125 VAC, 30 VDC
Ambient temperature: 20 2°C
2
1
Ambient humidity: 65 5%
Without load
0.1
Operating frequency: 60 operations/min
cosφ = 1, 250 VAC
0.5
0.3
0.1
0
0.5 1
2
3
4
5
6
7
8
9 10 11 12
0
0.01 0.02
0.05
0.08 0.1
Switching current (A)
Switching current (A)
■ Mounting
■ Contact Form
Panel Mounting
SPDT
SPST-NC
SPST-NO
All switches may be panel mounted using M3 mounting screws with
plane washers or spring washers to securely mount the switch.
Tighten the screws to a torque of 0.39 to 0.59 N·m.
NC
NC
NO
NO
Two, 3.1-dia. mounting holes
or M3 screw holes
COM
COM
COM
10.3 0.1
22.2 0.1
Snap Action Switch VX
137
Dimensions
■ Terminals
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of 0.4 mm applies to all dimensions
2. The following illustrates the SPDT contact form
Solder terminals (A)
#187 Quick-connect terminals (C2)
(5.5)
(6.5)
(5.5)
(6.5)
2.9
2.9
(10)
(10)
t=0.5
t=0.5
Three, quick-connect terminals (#187)
Three, solder terminals
6.35
3.2 (see note)
6.35
3.2
4.75 0.1
4.75 0.1
1.6 dia.
2.4 dia.
1.6-dia. terminal hole
Note: The length to the center of the 1.6-dia. holes.
■ Dimensions and Operating Characteristics
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and dimensions are for solder terminal models. Refer to “Terminals” for models with quick-connect terminals (#187).
3. The
@ in the model number is for the terminal code. (A = Solder Terminal, C2 = #187 quick-connect terminal)
4. The operating characteristics are for operation in the A direction(
)
Pin Plunger Models
4.2
+0.13
20.2 0.25
2.8
3.1
PT
–0.03 dia. holes
A
VX-5-1@2
VX-5-1@3
VX-5-1
VX-5-1
VX-01-1
VX-01-1
2
3
2
3
Characteristics
VX-01-1@2
VX-01-1@3
2.8
OF max.
RF min.
PT max.
OT min.
MD max.
OP
25 gf
3 gf
50 gf
5 gf
2.8
OP
10.3 0.1
15.9 18.8
1.2 mm
+0.13
–0.03
1.0 mm
0.3 mm
3.1
1.6
2.8
10.3
3.4 0.15 dia.
Three, solder terminals
14.7 ± 0.4 mm
22.2 0.1
27.8
(10)
37.8 0.8
Short Hinge Lever Models
t = 0.5 (stainless-steel lever)
Characteristics VX-51-1@3 VX-011-1@3
VX-51-1
3
4.3
A
+0.13
–0.03 dia. holes
3.1
VX-011-1
3
OF max.
RF min.
PT max.
OT min.
MD max.
OP
50 gf (reference value)
4 gf (reference value)
1.6 mm
22.1
8.1
PT
2.8
2.8
10.3 0.1
OP
15.9 18.8
0.8 mm
0.5 mm
+0.13
–0.03
3.1
15.2 ± 0.5 mm
1.6
10.3
3.4 0.15 dia.
Note: The reference value applies for cases when the
installation direction is such that the lever weight
is not applied to the plunger
2.8
Three, solder terminals
22.2 0.1
(10)
27.8
37.8 0.8
Hinge Lever Models
t = 0.5 (stainless-steel lever)
4.3
Characteristics VX-52-1@3 VX-012-1@3
VX-52-1
3
+0.13
35.6 0.8
8.1
3.1
A
–0.03 dia. holes
VX-012-1
3
PT
OF max.
RF min.
PT max.
OT min.
MD max.
OP
30 gf
- - -
2.8
2.8
4.0 mm
OP
10.3 0.1
15.9 18.8
1.6 mm
0.8 mm
+0.13
–0.03
3.1
15.2 ± 1.2 mm
1.6
2.8
10.3
3.4 0.15 dia.
Three, solder terminals
22.2 0.1
27.8
(10)
37.8 0.8
138
Snap Action Switch VX
Note: 1. Unless otherwise specified, all units are in millimeters and a tolerance of ±0.4 mm applies to all dimensions
2. The following illustrations and dimensions are for solder terminal models. Refer to “Terminals” for models with quick-connect terminals (#187).
3. The
@ in the model number is for the terminal code. (A = Solder Terminal, C2 = #187 quick-connect terminal)
4. The operating characteristics are for operation in the A direction(
)
Long Hinge Lever Models
t = 0.5 (stainless-steel lever)
Characteristics VX-53-1@3 VX-013-1@3
VX-53-1
3
4.3
+0.13
A
3.1
59.4 0.8
VX-013-1
3
–0.03 dia. holes
OF max.
RF min.
PT max.
OT min.
MD max.
OP
20 gf
- - -
PT
8.1
2.8
2.8
9.0 mm
OP
10.3 0.1
3.2 mm
15.9 18.8
2.0 mm
+0.13
–0.03
3.1
15.2 ± 2.6 mm
1.6
2.8
10.3
3.4 0.15 dia.
Three, solder terminals
22.2 0.1
27.8
(10)
37.8 0.8
Simulated Roller Lever Models
Characteristics VX-54-1@3 VX-014-1@3
VX-54-1
3
3.5R
t = 0.5 (stainless-steel lever)
VX-014-1
3
OF max.
RF min.
PT max.
OT min.
MD max.
OP
30 gf
2 gf
A
4.3
32.6 0.8
PT
+0.13
3.1
–0.03 dia. holes
8.1
2.8
4.0 mm
1.6 mm
2.8
3.1
OP
10.3 0.1
0.8 mm
15.9 18.8
18.7 ± 1.2 mm
+0.13
–0.03
10.3
Three, solder terminals
1.6
2.8
3.4 0.15 dia.
22.2 0.1
27.8
(10)
37.8 0.8
Short Hinge Roller Lever Models
Characteristics VX-55-1@3 VX-015-1@3
VX-55-1
3
4.8 dia. × 4.8 (oilless polyacetar resin roller)
t = 0.5 (stainless-steel lever)
VX-015-1
3
OF max.
RF min.
PT max.
OT min.
MD max.
OP
60 gf (reference value)
4 gf (reference value)
1.6 mm
A
5.1
PT
20.1
+0.13
–0.03 dia. holes
3.1
8.1
OP 2.8
0.8 mm
10.3 0.1
0.5 mm
15.9 18.8
20.7 ± 0.6 mm
+0.13
–0.03
3.1
Note: The reference value applies for cases when the
installation direction is such that the lever weight
is not applied to the plunger
10.3
3.4 0.15 dia.
1.6
2.8
Three, solder terminals
22.2 0.1
27.8
(10)
37.8 0.8
Hinge Roller Lever Models
Characteristics VX-56-1@3 VX-016-1@3
4.8 dia. × 4.8
VX-56-1
3
(oilless polyacetar resin roller)
t = 0.5 (stainless-steel lever)
VX-016-1
3
OF max.
RF min.
PT max.
OT min.
MD max.
OP
30 gf
- - -
A
34.0 0.8
5.1
PT
+0.13
3.1
–0.03 dia. holes
8.1
4.0 mm
2.8
1.6 mm
10.3 0.1
OP
0.8 mm
15.9 18.8
20.7 ± 1.2 mm
+0.13
–0.03
3.1
1.6
2.8
10.3
3.4 0.15 dia.
Three, solder terminals
22.2 0.1
27.8
(10)
37.8 0.8
Snap Action Switch VX
139
Precautions
■ Correct Use
■ Cautions
Mounting Direction
Handling
For a switch with an actuator, mount the switch in a direction where
the actuator weight will not be applied to the switch.
Be careful not to drop the switch. Doing so may cause damage to the
switch’s internal components because it is designed for a small load.
Since the switch is designed for a small load, its resetting force is
small. Therefore, resetting failure may occur if unnecessary load is
applied to the switch.
Solder Terminal Connection
Quickly finish the soldering of the lead wire to its terminal. Use a sol-
dering iron rated at 60W and preferably complete the soldering within
5 seconds.
Operation
Keep the operation control completely separate from the actuator of
the switch, and push it down fully when starting operation. Do not dis-
place the operating position of the actuator when machining.
Excess wattage or prolonged heating can deteriorate the characteris-
tics of the switch.
Insulation Distance
Consult OMRON in advance if the operating speed is to be extremely
slow, or if the pushbutton is to be set somewhere between the free
position and operating position.
When mounting, make sure there is sufficient insulation distance
between the switch and its mounting panel. If it is insufficient, install
an insulation guard or separator. Always install an insulation guard or
separator when mounting the microswitch on a metallic body. Con-
tact your OMRON representative for information about insulation
guards and separators.
Mount pin pushbutton switches so that stroke of the pushbutton and
the stroke of the operating control overlap on a vertical line. The
stroke of the switch, after operation, should be set to 60- 90% that of
standard OT (MIN operation).
Application Environment
Using Microloads
Do not use the Switch in locations that are subject to toxic gas, sili-
con, excessive dust, excessive dirt, high temperatures, high humidity,
sudden temperature changes, water splashes, or oil splashes.
Otherwise, damage resulting by faulty contact of the Switch contacts,
corrosion, or other causes, or other functional faults may occur.
Using a model for ordinary loads to switch microloads may result in
faulty operation. Instead, use the models that are designed for micro-
loads and that operate in the following range;
Depending on environmental conditions, the switch should be
rechecked about 3 to 6 months after it has been assembled.
26mA
100mA
0.16mA
30
24
Operating
range for
general-
load models
VX-5
Operating range
for micro load
models VX-01
12
Inoperable
range
5
0
1mA
1
100mA
100
160mA
10
1,000
0.1
Current (mA)
However, even when using microload models within the operating
range shown above, if inrush current or inductive voltage spikes
occur when the contact is opened or closed, it may increase contact
wear and so decrease the service life. Therefore, insert a contact
protection circuit where necessary.
140
Snap Action Switch VX
(b) Use in consumer Products or any use in significant quantities.
(c) Energy control systems, combustion systems, railroad systems, aviation systems,
medical equipment, amusement machines, vehicles, safety equipment, and
installations subject to separate industry or government regulations.
(d) Systems, machines, and equipment that could present a risk to life or property.
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY
SELLER.
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of
a programmable Product.
Omron Electronic Components, LLC
Terms and Conditions of Sales
I. GENERAL
1. Definitions: The words used herein are defined as follows.
(a) Terms:
(b) Seller:
(c) Buyer:
These terms and conditions
Omron Electronic Components LLC and its subsidiaries
The buyer of Products, including any end user in section III through VI
(d) Products: Products and/or services of Seller
(e) Including: Including without limitation
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,
invoices, purchase orders and other documents, whether electronic or in writing, relating
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's
purchase order or other documents which are inconsistent with, or in addition to, these
Terms.
3. Distributor: Any distributor shall inform its customer of the contents after and including
section III of these Terms.
IV. WARRANTY AND LIMITATION
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in
materials and workmanship for a period of twelve months from the date of sale by Seller
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE OF THE PRODUCTS.
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form
originally shipped with Buyer responsible for labor charges for removal or replacement
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an
amount equal to the purchase price of the Product; provided that there shall be no
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were
correctly handled, stored, installed and maintained and not subject to contamination,
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be
approved in writing by Seller before shipment.
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its
employees from and against all liabilities, losses, claims, costs and expenses (including
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or
omissions under these Terms or in any way with respect to the Products.
II. SALES
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.
Buyer agrees to pay the price in effect at the time the purchase order is accepted by
Seller. Payments for Products received are due net 30 days unless otherwise stated in
the invoice. Buyer shall have no right to set off any amounts against the amount owing in
respect of this invoice.
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to
Buyer after deducting transportation charges, taxes and duties, and will be allowed only
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past
due amounts owing to Seller.
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum
legal rate, whichever is less, on any balance not paid within the stated terms.
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer
shall make remittance to Seller at the then current exchange rate most favorable to
Seller; provided that if remittance is not made when due, Buyer will convert the amount
to U.S. dollars at the then current exchange rate most favorable to Seller available
during the period between the due date and the date remittance is actually made.
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining
any government approvals regarding the importation or sale of the Products.
7. Taxes: All taxes, duties and other governmental charges (other than general real
property and income taxes), including any interest or penalties thereon, imposed directly
or indirectly on Seller or required to be collected directly or indirectly by Seller for the
manufacture, production, sale, delivery, importation, consumption or use of the Products
sold hereunder (including customs duties and sales, excise, use, turnover and license
taxes) shall be charged to and remitted by Buyer to Seller.
V. INFORMATION; ETC.
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way
without the written permission of Seller. Buyer (at its own expense) shall indemnify and
hold harmless Seller and defend or settle any action brought against Seller to the extent
that it is based on a claim that any Product made to Buyer specifications infringed
intellectual property rights of another party.
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or
tooling, all engineering and tooling shall remain the exclusive property of Seller. All
information and materials supplied by Seller to Buyer relating to the Products are
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted
employees and strictly prevent disclosure to any third party.
3. Performance Data: Performance data is provided as a guide in determining suitability
and does not constitute a warranty. It may represent the result of Seller's test conditions,
and the users must correlate it to actual application requirements.
4. Change In Specifications: Product specifications and descriptions may be changed at
any time based on improvements or other reasons. It is Seller’s practice to change part
numbers when published ratings or features are changed, or when significant
engineering changes are made. However, some specifications of the Product may be
changed without any notice.
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,
Seller reserves the right to stop shipments or require satisfactory security or payment in
advance. If Buyer fails to make payment or otherwise comply with these Terms or any
related agreement, Seller may (without liability and in addition to other remedies) cancel
any unshipped portion of Products sold hereunder and stop any Products in transit until
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid
accounts.
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer
indemnifies Seller fully against all costs or expenses arising in connection therewith.
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from
causes beyond its control, including earthquakes, fires, floods, strikes or other labor
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,
delay in or lack of transportation or the requirements of any government authority.
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise
stated in writing by Seller), at which point title to and all risk of loss of the Products
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in
the Products until the full purchase price is paid by Buyer;
5. Errors And Omissions: The information on Seller’s website or in other documentation
has been carefully checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses
regarding (a) export of the Products or information provided by Seller; (b) sale of
Products to forbidden or other proscribed persons or organizations; (c) disclosure to non-
citizens of regulated technology or information.
(b) Delivery and shipping dates are estimates only; and
(c) Seller will package Products as it deems proper for protection against normal
handling and extra charges apply to special conditions.
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products
occurring before delivery to the carrier or any claim related to pricing or other charges
must be presented in detail in writing to Seller within 30 days of receipt of shipment.
III. PRECAUTIONS
VI. MISCELLANEOUS
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.
Buyer acknowledges that it alone has determined that the Products will meet their
requirements of the intended use in all cases. Buyer must know and observe all
prohibitions of use applicable to the Product/s.
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing
between Buyer and Seller shall operate as a waiver of rights by Seller.
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any
dispute hereunder.
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller
relating to the Products, and no provision may be changed or waived unless in writing
signed by the parties.
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall
not invalidate any other provision.
2. Use with Attention: The followings are some examples of applications for which
particular attention must be given. This is not intended to be an exhaustive list of all
possible use of any Product, nor to imply that any use listed may be suitable for any
Product:
(a) Outdoor use, use involving potential chemical contamination or electrical
interference.
Snap Action Switch VX
Certain Precautions on Specifications and Use
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-
dards, codes or regulations which apply to the combination of the Product in
gramming of a programmable product, or any consequence thereof.
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as
vide applicable third party certification documents identifying ratings and limi-
tations of use which apply to the Product. This information by itself is not
sufficient for a complete determination of the suitability of the Product in com-
bination with the end product, machine, system, or other application or use.
a guide for the user in determining suitability and does not constitute a war-
ranty. It may represent the result of Seller's test conditions, and the users must
correlate it to actual application requirements. Actual performance is subject to
Seller's Warranty and Limitations of Liability.
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be
ticular Product with respect to Buyer's application, product or system. Buyer
shall take application responsibility in all cases but the following is a non-
exhaustive list of applications for which particular attention must be given:
(i) Outdoor use, uses involving potential chemical contamination or electrical
interference, or conditions or uses not described in this document.
(ii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety
equipment, and installations subject to separate industry or government
regulations.
(iii) Use in consumer products or any use in significant quantities.
(iv) Systems, machines and equipment that could present a risk to life or
property. Please know and observe all prohibitions of use applicable to this
product.
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Seller representative at any time to
confirm actual specifications of purchased Product.
5. Errors and Omissions. The information in this publication has been carefully
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors, or omissions.
6. RoHS Compliance. Where indicated, our products currently comply, to the
best of our knowledge as of the date of this publication, with the requirements
of the European Union's Directive on the Restriction of certain Hazardous
Substances ("RoHS"), although the requirements of RoHS do not take effect
until July 2006. These requirements may be subject to change. Please consult
our website for current information.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
11/09
Specifications subject to change without notice
Printed in USA
Cat. No. X303-E-1
Snap Action Switch VX