TL-Q5ME2-3 [OMRON]

SENSOR PROXIMITY NC 5MM;
TL-Q5ME2-3
型号: TL-Q5ME2-3
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

SENSOR PROXIMITY NC 5MM

文件: 总12页 (文件大小:1195K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Rectangular Standard Proximity Sensor  
TL-N/TL-Q  
CSM_TL-N/TL-Q_DS_E_14_1  
A Wealth of Models for All Types of  
Applications  
• Easy installation, high-speed pulse generator, high-speed  
rotation control, and more.  
• Direct mounted to metal (-N Models).  
• A wealth of models ideal for limit control, counting control, and  
other applications (-N Models).  
For the most recent information on models that have been certified for  
safety standards, refer to your OMRON website.  
Ordering Information  
Sensors [Refer to Dimensions on page 10.]  
DC 2-Wire Models  
Model  
Operation mode  
Appearance  
Sensing distance  
NO  
NC  
17 × 17  
TL-Q5MD1 2M *1 *2  
TL-N7MD1 2M *1  
TL-N12MD1 2M *1  
TL-N20MD1 2M *1  
TL-Q5MD2 2M *1  
5 mm  
25 × 25  
30 × 30  
40 × 40  
TL-N7MD2 2M *1  
TL-N12MD2 2M *1  
TL-N20MD2 2M *1  
Unshielded  
7 mm  
12 mm  
20 mm  
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-N@MD@5 and TL-Q5MD@5 (e.g., TL-N7MD15).  
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MD1-R 2M)  
DC 3-Wire and AC 2-Wire Models  
Model  
Operation mode  
Appearance  
Sensing distance  
Output configuration  
NO  
NC  
8 × 9  
TL-Q2MC1 2M  
2 mm  
5 mm  
DC 3-wire, NPN  
TL-Q5MC1 2M *1 *2  
TL-Q5MB1 2M  
TL-Q5MC2 2M  
17 × 17  
25 × 25  
DC 3-wire, PNP  
DC 3-wire, NPN  
AC 2-wire  
TL-N5ME1 2M *1 *2  
TL-N5MY1 2M *1  
TL-N10ME1 2M *1 *2  
TL-N10MF1 2M *1  
TL-N10MY1 2M *1  
TL-N20ME1 2M *1 *2  
TL-N20MY1 2M *1  
TL-N5ME2 2M *1  
TL-N5MY2 2M *1  
TL-N10ME2 2M *1  
5 mm  
Unshielded  
DC 3-wire, NPN  
DC 3-wire, PNP  
AC 2-wire  
30 × 30  
40 × 40  
10 mm  
TL-N10MY2 2M *1  
TL-N20ME2 2M *1  
TL-N20MY2 2M *1  
DC 3-wire, NPN  
AC 2-wire  
20 mm  
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-@@M@@5 (e.g., TL-N5ME15).  
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MC1-R 2M)  
1
TL-N/TL-Q  
Accessories (Order Separately)  
Mounting Brackets A Mounting Bracket is provided with the Sensor depending on the model number. Check the column for the applicable Sensor.  
[Refer to Dimensions on page 11.]  
Applicable Sensors  
Type  
Model  
Y92E-C5  
Provided with these Sensors  
Order separately  
TL-N5MY@  
TL-N5ME@, TL-N7MD@  
TL-N10ME@, TL-N12MD@,  
TL-N10MF1@  
Mounting Brackets  
Y92E-C10  
TL-N10MY@  
Y92E-C20  
TL-N20ME@, TL-N20MD@  
TL-N20MY@  
Y92E-N5C15  
Y92E-N10C15  
---  
---  
TL-N5ME@, TL-N5MY@  
TL-N10ME@, TL-N10MY@  
Mounting Brackets for Conduits  
Ratings and Specifications  
DC 2-Wire Models  
Item  
Model  
TL-Q5MD@  
5 mm 10%  
TL-N7MD@  
TL-N12MD@  
TL-N20MD@  
20 mm 10%  
0 to 16 mm  
Sensing distance  
Set distance  
7 mm 10%  
0 to 5.6 mm  
12 mm 10%  
0 to 9.6 mm  
0 to 4 mm  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)  
Standard sensing  
object  
Iron, 18 × 18 × 1 mm  
Iron, 30 × 30 × 1 mm  
Iron, 40 × 40 × 1 mm  
Iron, 50 × 50 × 1 mm  
Response  
frequency *  
500 Hz  
300 Hz  
Power supply voltage  
(operating voltage  
range)  
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
Leakage current  
Load  
0.8 mA max.  
3 to 100 mA  
current  
Control  
output  
Residual  
voltage  
3.3 V max. (Load current: 100 mA, Cable length: 2 m)  
D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
Indicators  
Operation mode  
(with sensing object  
approaching)  
D1 Models: NO  
D2 Models: NC  
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.  
Protection circuits  
Load short-circuit protection, Surge suppressor  
Ambient  
temperature range  
Operating/Storage: 25 to 70°C (with no icing or condensation)  
Ambient  
humidity range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature influence 10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
Voltage influence  
Insulation resistance  
Dielectric strength  
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
1,000 VAC for 1 min between current-carrying parts and case  
Vibration  
resistance  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 3 times  
Shock resistance  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions  
each in X, Y, and Z directions  
Degree of protection  
Connection method  
IEC 60529 IP67, in-house standards: oil-resistant  
Pre-wired Models (Standard cable length: 2 m)  
Weight (packed state) Approx. 85 g  
Approx. 165 g  
Approx. 235 g  
Approx. 330 g  
Case  
Materials  
Heat-resistant ABS  
Sensing  
surface  
Mounting Bracket,  
Mounting phillips screws (M4  
Instruction manual  
Mounting Bracket,  
25), Mounting phillips screws (M4  
Instruction manual  
Mounting Bracket,  
30), Mounting phillips screws (M5  
Instruction manual  
Accessories  
Instruction manual  
40),  
* The response frequency is an average value.  
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.  
2
TL-N/TL-Q  
DC 3-Wire Models  
Item  
Model  
TL-Q2MC1  
TL-Q5MC@/TL-Q5MB1  
Sensing  
distance  
2 mm 15%  
0 to 1.5 mm  
5 mm 10%  
0 to 4 mm  
Set distance  
Differential travel  
Detectable object  
10% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.)  
Standard  
sensing object  
Iron, 8 × 8 × 1 mm  
Iron, 15 × 15 × 1 mm  
Response time  
---  
2 ms max.  
Response  
frequency *  
500 Hz  
Power supply volt-  
age (operating volt- 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
age range)  
Current  
15 mA max. at 24 VDC (no-load)  
consumption  
10 mA max. at 24 VDC  
TL-Q5MC@: NPN open collector,  
Load  
current  
NPN open collector  
100 mA max. at 30 VDC max.  
50 mA max. at 30 VDC max.  
TL-Q5MB@: PNP open collector,  
Control  
output  
50 mA max. at 30 VDC max.  
Residual  
voltage  
1 V max. (under load current of 100 mA with cable length of 1 V max. (under load current of 50 mA with cable length of  
2 m)  
2 m)  
Indicators  
Detection indicator (red)  
B1/C1 Models: NO  
C2 Models: NC  
Operation mode  
(withsensingobject  
approaching)  
NO  
Refer to the timing charts under DC 3-Wire Models on page 7 for details.  
Protection  
circuits  
Reverse polarity protection, Surge suppressor  
Ambient  
temperature range  
Operating/Storage: 10 to 60°C (with no icing or condensa- Operating/Storage: 25 to 70°C (with no icing or condensa-  
tion)  
tion)  
Ambient  
humidity range  
Operating/Storage: 35% to 95% (with no condensation)  
Temperature  
influence  
10% max. of sensing distance at 23°C in the temperature  
range of 10 to 60°C  
20% max. of sensing distance at 23°C in the temperature  
range of 25 to 70°C  
Voltage  
influence  
2.5% max. of sensing distance at rated voltage in rated voltage 10% range  
Insulation  
resistance  
50 MΩ min. (at 500 VDC) between current-carrying parts  
and case  
5 MΩ min. (at 500 VDC) between current-carrying parts and  
case  
1,000 VAC for 1 min between current-carrying parts and  
case  
500 VAC, 50/60 Hz for 1 min between current-carrying parts  
and case  
Dielectric strength  
Vibration  
resistance  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 1,000 m/s2 10 times each in X, Y, and Z direc- Destruction: 200 m/s2 10 times each in X, Y, and Z direc-  
Shock resistance  
tions  
tions  
Degree of  
protection  
IEC 60529 IP67,  
in-house standards: oil-resistant  
IEC IP67  
Connection  
method  
Pre-wired Models (Standard cable length: 2 m)  
Weight  
(packed state)  
Approx. 60 g  
Approx. 90 g  
Case  
Materi-  
als  
Heat-resistant ABS  
Instruction manual  
Sensing  
surface  
Accessories  
---  
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and  
a set distance of half the sensing distance.  
3
TL-N/TL-Q  
TL-N10ME@, TL-N10MY@,  
Item  
Model  
TL-N5ME@, TL-N5MY@  
5 mm 10%  
TL-N20ME@, TL-N20MY@  
20 mm 10%  
0 to 16 mm  
TL-N10MF1  
Sensing distance  
Set distance  
10 mm 10%  
0 to 8 mm  
0 to 4 mm  
Differential travel  
Detectable object  
15% max. of sensing distance  
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 6 and 7.)  
Standard  
sensing object  
Iron, 30 × 30 × 1 mm  
Iron, 40 × 40 × 1 mm  
Iron, 50 × 50 × 1 mm  
Response  
frequency *1  
E/F Models: 500 Hz  
Y Models: 10 Hz  
E Models: 40 Hz  
Y Models: 10 Hz  
Power supply  
voltage *2  
E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.  
(operating voltage Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz  
range)  
Current  
consumption  
E/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC  
Leakage current  
Y Models: Refer to Engineering Data on page 5.  
Load  
current  
E/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC  
Y Models: 10 to 200 mA  
Control  
output  
Residual E/F Models: 1 V max. (load current: 200 mA)  
voltage  
Y Models: Refer to Engineering Data on page 5.  
E/F Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
Indicators  
E1/F1/Y1 Models: NO  
E2/Y2 Models: NC  
Operation mode  
(with sensing ob-  
ject approaching)  
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.  
E Models: Reverse polarity protection, Surge suppressor  
Y Models: Surge suppressor  
Protection circuits  
Ambient  
Operating/Storage: 25 to 70°C (with no icing or condensation)  
Operating/Storage: 35% to 95% (with no condensation)  
temperature range  
Ambient  
humidity range  
Temperature  
influence  
10% max. of sensing distance at 23°C in the temperature range of 25 to 70°C  
E/F Models: 2.5% max. of sensing distance at rated voltage in rated voltage 10% range  
Y Models: 1% max. of sensing distance at rated voltage in rated voltage 10% range  
Voltage influence  
Insulation  
resistance  
50 MΩ min. (at 500 VDC) between current-carrying parts and case  
E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case  
Dielectric strength  
Vibration  
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions  
Destruction: 500 m/s2 10 times each in X, Y, and Z directions  
resistance  
Shock resistance  
Degree of  
protection  
IEC 60529 IP67, in-house standards: oil-resistant  
Connection  
method  
Pre-wired Models (Standard cable length: 2 m)  
Weight  
(packed state)  
Approx. 190 g  
Approx. 240 g  
Approx. 340 g  
Case  
Materi-  
als  
Heat-resistant ABS  
Sensing  
surface  
E Models: Mounting Bracket,  
E Models: Mounting Bracket,  
E/F Models: Mounting Bracket,  
Mounting phillips screws (M4 30),  
Mounting phillips screws (M5  
40),  
Mounting phillips screws (M4  
25),  
Accessories  
Instruction manual  
Instruction manual  
Instruction manual  
Y Models: Instruction manual  
Y Models: Instruction manual  
Y Models: Instruction manual  
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and  
a set distance of half the sensing distance.  
*2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC 10% (average value) can be used.  
4
TL-N/TL-Q  
Engineering Data (Reference Value)  
Sensing Area  
TL-Q2MC1  
TL-Q5M@@  
TL-N@ME@  
TL-N@MY@  
Y
X
5
4
3
2
1
0
TL-N20  
20  
4
3
2
1
0
15  
Y
X
TL-N10  
10  
TL-N5  
Y
X
5
0
8  
6  
4  
2  
0
2
4
6
8 6 4 2  
0
2
4
6
8
25 20 15 10 5  
0
5
10 15 20  
TL-N5 Sensing Head  
TL-N10 Sensing Head  
TL-N20 Sensing Head  
Distance Y (mm)  
Distance Y (mm)  
Sensing Head  
Sensing Head  
Distance Y (mm)  
Leakage Current  
TL-N@MD@  
TL-N@MY  
TL-N20MD@  
2.0  
1.5  
1.0  
0.5  
20  
15  
TL-N12MD@  
10  
Protective resistance  
mA  
TL-N7MD@  
Y
X
AC  
power  
50/60  
Hz  
5
V
Proximity Sensor  
(output OFF)  
0
0
80 100 120 140 160 180 200 220 240 260  
Power supply voltage (V)  
-25 -20 -15 -10  
-5  
0
5
10 15 20  
TL-N7MD@ Sensing Head  
Distance Y (mm)  
TL-N12MD@ Sensing Head  
TL-N20MD@ Sensing Head  
Residual Output Voltage  
TL-N@MD  
TL-N@MY at 100 VAC  
TL-N@MY at 200 VAC  
5
Residual output voltage  
Residual output voltage  
100  
200  
160  
120  
80  
4
3
2
1
ON  
ON  
80  
60  
V
V
200 VAC  
100 VAC  
A
A
40  
40  
20  
Residual  
Residual  
load voltage  
load  
voltage  
OFF  
100 200  
Load current (mA)  
OFF  
30 50 100 200  
Load current (mA)  
0
3
5
10 20  
50  
0
3
5
10 20  
0
3
5
10  
30 50 100  
300 500 1,000  
Load current (mA)  
5
TL-N/TL-Q  
Sensing Object Size vs. Sensing Distance  
TL-Q5MC@  
7
t = 1 mm  
6
5
d ×  
d
4
X
3
2
1
0
10  
20  
30  
40  
Side length of sensing object: d (mm)  
Influence of Sensing Object Size and Material  
TL-Q2MC1  
TL-Q5M@@  
TL-N5@  
4
6
d ×  
d ×  
d
d
d ×  
t = 1 mm  
d
6
5
4
3
2
1
X
X
5
X
Iron  
3
2
1
Iron  
4
3
2
1
Stainless steel  
(SUS304)  
Iron  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Brass  
Brass  
Aluminum  
Copper  
Aluminum  
Aluminum  
Brass  
0
10  
20  
30  
40  
50  
60 70  
80  
0
10  
20  
30  
40  
50  
60  
0
5
10  
15  
20  
25  
30 35  
40 45  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
TL-N7MD@  
TL-N12MD@  
TL-N20MD@  
10  
14  
24  
d ×  
d ×  
d ×  
d
d
d
t = 1 mm  
t = 1 mm  
Iron  
t = 1 mm  
12  
10  
8
X
X
Iron  
X
20  
16  
12  
8
8
Iron  
6
4
2
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
6
Brass  
Brass  
Brass  
Copper  
Aluminum  
Copper  
Aluminum  
4
Aluminum  
Copper  
4
2
0
10  
20  
30  
40  
50  
60  
0
10  
20  
30  
40  
50  
60  
0
10  
20  
30  
40  
50  
60  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
6
TL-N/TL-Q  
TL-N10@  
TL-N20@  
d ×  
d ×  
22  
d
d
t = 1 mm  
t = 1 mm  
Iron  
Iron  
X
X
10  
8
20  
18  
16  
14  
12  
10  
8
6
Stainless steel  
(SUS304)  
Stainless steel  
(SUS304)  
4
Brass  
Brass  
6
Aluminum  
Aluminum  
2
4
2
0
10  
20  
30  
40  
50  
60 70  
80  
0
10  
20  
30  
40  
50  
60 70  
80  
Side length of sensing object: d (mm)  
Side length of sensing object: d (mm)  
I/O Circuit Diagrams  
Operation  
Output  
configuration  
Model  
mode  
Timing chart  
Output circuit  
Set position  
Stable sensing  
area  
Unstable  
sensing  
area  
Non-sensing  
area  
Proximity Sensor  
Sensing  
object  
TL-Q5MD1  
TL-N7MD1  
TL-N12MD1  
TL-N20MD1  
(%)  
100 80 (TYP)  
0
NO  
Rated  
sensing  
distance  
ON  
OFF  
Setting indicator  
(green)  
Brown  
ON  
Load  
Operation indicator  
(red)  
+V  
OFF  
ON  
Proximity  
Sensor  
main  
Control output  
OFF  
DC 3-wire,  
NPN  
circuit  
Sensing  
area  
Non-sensing  
area  
Blue  
0 V  
Proximity Sensor  
Note: The load can be connected to either  
the +V or 0 V side.  
Sensing  
object  
TL-Q5MD2  
TL-N7MD2  
TL-N12MD2  
TL-N20MD2  
(%)  
100  
0
NC  
Rated  
sensing  
distance  
ON  
Operation indicator  
(red)  
OFF  
ON  
Control output  
OFF  
7
TL-N/TL-Q  
Operation  
mode  
Output  
configuration  
Model  
Timing chart  
Output circuit  
Present  
Not present  
ON  
Sensing object  
Brown  
TL-Q2MC1  
TL-Q5MC1  
+V  
Output transistor  
(load)  
NO  
NC  
100 Ω  
OFF  
Load  
Proximity  
Sensor  
main  
ON  
Detection indicator  
(red)  
*
Black  
OFF  
DC 3-wire,  
NPN  
Output  
circuit  
Present  
Not present  
ON  
Sensing object  
Blue  
0 V  
Output transistor  
(load)  
TL-Q5MC2  
* Load current: 100 mA max., TL-Q2MC1  
Load current: 50 mA max., TL-Q5MC1  
OFF  
ON  
Detection indicator  
(red)  
OFF  
Brown  
+V  
Present  
Not present  
ON  
Sensing object  
Proximity  
Sensor  
main  
Black  
DC 3-wire,  
PNP  
Output transistor  
(load)  
TL-Q5MB1  
NO  
Output  
*
circuit  
OFF  
Load  
ON  
Detection indicator  
(red)  
OFF  
Blue  
0 V  
* Load current: 50 mA max.  
Present  
Not present  
Operate  
Reset  
Sensing object  
Load (between brown  
and black leads)  
TL-N5ME1  
TL-N10ME1  
TL-N20ME1  
Brown  
+V  
NO  
100 Ω  
High  
Output voltage (between  
black and blue leads)  
Load  
Low  
4.7 kΩ  
ON  
Proximity  
Sensor  
main  
*1  
Detection indicator (red)  
Black  
OFF  
DC 3-wire,  
NPN  
2.2 Ω  
Output  
*2  
circuit  
Tr  
Present  
Not present  
Operate  
Sensing object  
Blue  
0 V  
Load (between brown  
and black leads)  
TL-N5ME2  
TL-N10ME2  
TL-N20ME2  
Reset  
*1. Load current: 200 mA max.  
NC  
High  
Low  
ON  
Output voltage (between  
black and blue leads)  
*2. When a transistor is connected.  
Detection indicator (red)  
OFF  
Brown  
+V  
Present  
Not present  
Operate  
Reset  
Sensing object  
Tr  
Proximity  
Sensor  
main  
*2  
2.2 Ω  
4.7 kΩ  
Black  
Load (between black  
and blue leads)  
DC 3-wire,  
PNP  
Output  
TL-N10MF1  
NO  
circuit  
Output voltage (between  
brown and black leads)  
High  
*1  
Load  
Low  
100 Ω  
Blue  
ON  
0 V  
Detection indicator (red)  
OFF  
*1. Load current: 200 mA max.  
*2. When a transistor is connected.  
Present  
Sensing object  
Load  
Not present  
Operate  
Reset  
TL-N5MY1  
TL-N10MY1  
TL-N20MY1  
NO  
NC  
Brown  
Load  
ON  
Operation indicator (red)  
Proximity  
Sensor  
main  
OFF  
AC 2-wire  
circuit  
Present  
Not present  
Operate  
Reset  
Sensing object  
Load  
TL-N5MY2  
TL-N10MY2  
TL-N20MY2  
Blue  
ON  
Operation indicator (red)  
OFF  
8
TL-N/TL-Q  
Safety Precautions  
Refer to Warranty and Limitations of Liability.  
WARNING  
This product is not designed or rated for ensuring  
safety of persons either directly or indirectly.  
Do not use it for such purposes.  
Do not short-circuit the load, otherwise the Sensor may  
be damaged.  
Do not supply power to the Sensor with no load,  
otherwise the Sensor may be damaged.  
Applicable Models: AC 2-Wire Models  
Precautions for Correct Use  
Do not use this product under ambient conditions that exceed the  
ratings.  
Design  
Influence of Surrounding Metal  
Mutual Interference  
When mounting the Sensor within a metal panel, ensure that the  
clearances given in the following table are maintained. Failure to  
maintain these distances may cause deterioration in the performance  
of the Sensor.  
When installing Sensors face-to-face or side-by-side, ensure that the  
minimum distances given in the following table are maintained.  
Face-to-face  
Parallel  
A
TL-N*2  
Rectangular Models  
TL-Q  
B*1  
B
B*1  
A
Mutual Interference (Unit: mm)  
A
Model  
Distance  
A *  
B *  
TL-Q5MC@, TL-Q5MB1  
TL-Q5MD@  
TL-N7MD@  
TL-N12MD@  
TL-N20MD@  
TL-N5ME@  
TL-N5MY@  
TL-N10ME@, TL-N10MF1, TL-N10MY@  
TL-N20ME@, TL-N20MY@  
60 (17)  
60 (30)  
120 (60)  
120 (80)  
120 (60)  
200 (100)  
Influence of Surrounding Metal (Unit: mm)  
Model  
Distance  
A
B *1  
20  
35  
40  
60  
23  
30  
45  
100 (50)  
120 (60)  
TL-Q5M@@, TL-Q5MB1  
TL-N7MD@  
TL-N12MD@  
TL-N20MD@  
TL-N5ME@, TL-N5MY@  
20  
40  
50  
70  
20  
40  
80  
200 (100) 300 (150)  
80 (40)  
80 (40)  
80 (40)  
90 (40)  
120 (60)  
200 (100)  
120 (60)  
120 (60)  
TL-N10ME@, TL-N10MF1, TL-N10MY@  
TL-N20ME@, TL-N20MY@  
* Values in parentheses apply to Sensors operating at different frequencies.  
*1. The B dimension applies to the top, right-side, and left-side surfaces.  
*2. The values for A or B for the TL-N apply when there is metal on only one side  
of the sensor. If there is metal on two or more sides of the sensor, the value  
must be multiplied by two or more.  
A
B
B
A
TL-Q2MC1  
Mutual Interference (Unit: mm)  
Mounting plate*  
TL-Q2MC1  
* The mounting plate  
Model  
Distance  
A *  
30 (8)  
B *  
90 (45)  
B
must be a non-  
ferrous metal.  
3 mm  
TL-Q2MC1  
* Values in parentheses apply to Sensors operating at different frequencies.  
Influence of Surrounding Metal (Unit: mm)  
Model  
Distance  
A
B
TL-Q2MC1  
12  
3
Mounting  
When tightening the mounting screws, do not exceed the torque in the  
following table.  
Model  
TL-Q2MC1  
TL-Q5M@@  
TL-N@M@@  
Torque  
0.59 N·m  
0.9 to 1.5 N·m  
9
TL-N/TL-Q  
(Unit: mm)  
Dimensions  
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.  
Sensors  
TL-Q2MC1  
1
*
6
Detection indicator (red)  
Sensing surface  
3.2-dia. mounting hole  
0.2  
18.5  
8
8
2.5  
9
25  
28  
* 2.9-dia. vinyl-insulated round cable with 3 conductors  
(Conductor cross section: 0.15 mm2, Insulator diameter:  
0.9 mm), Standard length: 2 m  
32 max.  
TL-Q5M@@  
28  
3.5  
*1  
Mounting Hole  
Dimensions  
17  
0.1  
17  
10.5  
0.1  
10.5  
Two, 3.3 dia.  
Indicators *2  
Two, 3.3-dia. holes  
16  
3
*1. B/C Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2,  
Insulator diameter: 1.2 mm), Standard length: 2 m  
D Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2,  
Insulator diameter: 1.3 mm), Standard length: 2 m  
*2. B/C Models: Detection indicator (red)  
D Models: Operation indicator (red), Setting indicator (green)  
TL-N7MD@, TL-N5ME@  
Two, 4.3 dia.  
35  
0.45  
18  
25  
8 dia. 9 dia.  
Indicator *2  
6
23.8  
Rubber bushing  
Mounting Hole Dimensions  
25  
Two, 4.5-dia. or M4 holes  
18.5  
*1  
18.5  
38.5  
0.5  
0.2  
18  
1.5  
*1. D Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
*2. D1 Models: Operation indicator (red), Setting indicator (green)  
D2 Models: Operation indicator (red)  
E Models: Detection indicator (red)  
TL-N5MY@  
TL-N12MD@,  
TL-N10ME@,  
TL-N10MY@  
0.1  
Two, 4.3 dia.  
49  
Two, 4.3 dia.  
46.3  
30  
0.45  
22  
8 dia. 9 dia.  
0.45  
25  
18  
35.8  
Indicator *2  
7.7  
8 dia. 9 dia.  
Operation indicator (red)  
6.2  
0.5  
34.1  
Mounting Hole Dimensions  
Mounting Hole  
Dimensions  
Rubber bushing  
30  
21.5  
Rubber bushing  
Two, 4.5-dia. or M4 holes  
25  
*1  
Two, 4.5-dia. or M4 holes  
18.5  
18.5  
52.5  
1.5  
0.5  
*
18.5  
1.5  
0.2  
18  
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator  
diameter: 1.9 mm), Standard length: 2 m  
E/Y Models: 6-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
*2. D1 Models: Operation indicator (red) and Setting indicator (green)  
D2 Models: Operation indicator (red)  
50  
0.2  
22  
* 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator diameter:  
1.9 mm), Standard length: 2 m  
E/Y Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
10  
TL-N/TL-Q  
TL-N20MD@, TL-N20ME@, TL-N20MY@  
Mounting Hole Dimensions  
47  
Two, 5.5 dia.  
Two, 5.5-dia. or M5 holes  
0.45  
10 dia. 12 dia.30  
40  
0.2  
30  
Indicator *2  
8
31.8  
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors  
(Conductor cross section: 0.5 mm2, Insulator  
diameter: 1.9 mm), Standard length: 2 m  
E Models: 6-dia. vinyl-insulated round cable with 3  
conductors (Conductor cross section: 0.5 mm2,  
Insulator diameter: 1.9 mm), Standard length: 2 m  
*2. D1 Models: Operation indicator (red) and Setting indicator (green)  
D2 Models: Operation indicator (red)  
Rubber bushing  
*1  
40  
30  
53  
25  
1
E Models: Detection indicator (red)  
Y Models: Operation indicator (red)  
Accessories (Order Separately)  
Mounting Bracket  
Y92E-C20  
Y92E-C5  
Y92E-C10  
Two, M4  
3.5  
34  
Two, M4  
32  
Two, M5  
35  
20  
18  
4
20  
19.5  
6
5.5  
4.5  
2.3  
4.5  
*1  
12  
0.2  
18  
25  
0.2  
0.2  
0.2  
30  
40  
*1 22  
0.2  
0.2  
30  
*1 16  
22  
9
6.5  
9.5  
7
2.3  
14.5  
3.2  
24  
Applicable Models: TL-N5ME@ *2  
Applicable Models: TL-N5MY@  
Applicable Models: TL-N7MD@ *2  
Material: Mounting Bracket: Zinc-plated iron  
Mounting Pan-head Phillips Screws:  
Nickel-plated iron  
Applicable Models: TL-N10ME@ *2  
Applicable Models: TL-N10MY@  
Applicable Models: TL-N12MD@ *2  
Material: Mounting Bracket: Zinc-plated iron  
Mounting Pan-head Phillips Screws:  
Nickel-plated iron  
Applicable Models: TL-N20ME@ *2  
Applicable Models: TL-N20MY@  
Applicable Models: TL-N20MD@ *2  
Material: Mounting Bracket: Zinc-plated iron  
Mounting Pan-head Phillips Screws:  
Nickel-plated iron  
(Size: M4, Length: 25 mm)  
(Size: M4, Length: 30 mm)  
(Size: M5, Length: 40 mm)  
*1. These are the mounting dimensions of the base of the Mounting Bracket.  
*2. Provided with the product.  
Mounting Brackets for Wiring Conduit Use (Sold Separately)  
Y92E-N10C15  
Y92E-N5C15  
30  
25  
0.3  
22  
13  
Two, 4.3 dia.  
3.5  
0.3  
18  
11  
Two, 4.3 dia.  
3.5  
0.2  
0.2  
21  
2.3  
18  
2.3  
5.5  
24.3  
2.3  
5
23.8  
2.3  
C15 conduit screw, JIS-B-0204  
C15 conduit screw, JIS-B-0204  
Applicable Models: TL-N10ME@  
Applicable Models: TL-N10MY@  
Applicable Models: TL-N12MD@  
Material: Zinc-plated iron  
Applicable Models: TL-N5ME@  
Applicable Models: TL-N5MY@  
Applicable Models: TL-N7MD@  
Material: Zinc-plated iron  
11  
Terms and Conditions Agreement  
Read and understand this catalog.  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you  
have any questions or comments.  
Warranties.  
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship  
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron  
disclaims all other warranties, express or implied.  
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER  
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE  
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.  
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the  
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at  
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or  
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount  
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,  
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products  
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate  
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall  
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or  
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,  
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above  
warranty.  
See http://www.omron.com/global/ or contact your Omron representative for published information.  
Limitation on Liability; Etc.  
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,  
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,  
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.  
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.  
Suitability of Use.  
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the  
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable  
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself  
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,  
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product  
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE  
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,  
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE  
OVERALL EQUIPMENT OR SYSTEM.  
Programmable Products.  
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence  
thereof.  
Performance Data.  
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining  
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate  
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.  
Change in Specifications.  
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our  
practice to change part numbers when published ratings or features are changed, or when significant construction changes are  
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers  
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at  
any time to confirm actual specifications of purchased Product.  
Errors and Omissions.  
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
2017.7  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2017 All Right Reserved.  

相关型号:

TL-R

Twist Lock Splice for 8-22 AWG Wire
MOLEX

TL-SCSI1285KC

IC VREG 2.85 V FIXED POSITIVE LDO REGULATOR, 0.8 V DROPOUT, PSFM3, POWER, PLASTIC, TO-220AB, 3 PIN, Fixed Positive Single Output LDO Regulator
TI

TL-SCSI1285N

IC VREG 2.85 V FIXED POSITIVE LDO REGULATOR, 0.8 V DROPOUT, PDIP14, Fixed Positive Single Output LDO Regulator
TI

TL-SCSI1285PWLE

2.85V FIXED POSITIVE LDO REGULATOR, 0.7V DROPOUT, PDSO20
TI

TL-SCSI285

FIXED-VOLTAGE REGULATORS FOR SCSI ACTIVE TERMINATION
TI

TL-SCSI285KC

FIXED-VOLTAGE REGULATORS FOR SCSI ACTIVE TERMINATION
TI

TL-SCSI285KCE3

FIXED-VOLTAGE REGULATORS FOR SCSI ACTIVE TERMINATION
TI

TL-SCSI285KCSE3

FIXED-VOLTAGE REGULATORS FOR SCSI ACTIVE TERMINATION
TI

TL-SCSI285MFK

IC,VOLT REGULATOR,FIXED,+2.85V,BIPOLAR,LLCC,20PIN,CERAMIC
TI

TL-SCSI285N

2.85V FIXED POSITIVE LDO REGULATOR, 0.8V DROPOUT, PDIP14, PLASTIC, DIP-14
TI

TL-SCSI285PW

FIXED-VOLTAGE REGULATORS FOR SCSI ACTIVE TERMINATION
TI

TL-SCSI285PWLE

暂无描述
TI