TL-Q5ME2-3 [OMRON]
SENSOR PROXIMITY NC 5MM;型号: | TL-Q5ME2-3 |
厂家: | OMRON ELECTRONICS LLC |
描述: | SENSOR PROXIMITY NC 5MM |
文件: | 总12页 (文件大小:1195K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Rectangular Standard Proximity Sensor
TL-N/TL-Q
CSM_TL-N/TL-Q_DS_E_14_1
A Wealth of Models for All Types of
Applications
• Easy installation, high-speed pulse generator, high-speed
rotation control, and more.
• Direct mounted to metal (-N Models).
• A wealth of models ideal for limit control, counting control, and
other applications (-N Models).
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Ordering Information
Sensors [Refer to Dimensions on page 10.]
DC 2-Wire Models
Model
Operation mode
Appearance
Sensing distance
NO
NC
17 × 17
TL-Q5MD1 2M *1 *2
TL-N7MD1 2M *1
TL-N12MD1 2M *1
TL-N20MD1 2M *1
TL-Q5MD2 2M *1
5 mm
25 × 25
30 × 30
40 × 40
TL-N7MD2 2M *1
TL-N12MD2 2M *1
TL-N20MD2 2M *1
Unshielded
7 mm
12 mm
20 mm
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-N@MD@5 and TL-Q5MD@5 (e.g., TL-N7MD15).
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MD1-R 2M)
DC 3-Wire and AC 2-Wire Models
Model
Operation mode
Appearance
Sensing distance
Output configuration
NO
NC
8 × 9
TL-Q2MC1 2M
—
2 mm
5 mm
DC 3-wire, NPN
TL-Q5MC1 2M *1 *2
TL-Q5MB1 2M
TL-Q5MC2 2M
—
17 × 17
25 × 25
DC 3-wire, PNP
DC 3-wire, NPN
AC 2-wire
TL-N5ME1 2M *1 *2
TL-N5MY1 2M *1
TL-N10ME1 2M *1 *2
TL-N10MF1 2M *1
TL-N10MY1 2M *1
TL-N20ME1 2M *1 *2
TL-N20MY1 2M *1
TL-N5ME2 2M *1
TL-N5MY2 2M *1
TL-N10ME2 2M *1
—
5 mm
Unshielded
DC 3-wire, NPN
DC 3-wire, PNP
AC 2-wire
30 × 30
40 × 40
10 mm
TL-N10MY2 2M *1
TL-N20ME2 2M *1
TL-N20MY2 2M *1
DC 3-wire, NPN
AC 2-wire
20 mm
*1. Models with a different frequency are available to prevent mutual interference. The model numbers are TL-@@M@@5 (e.g., TL-N5ME15).
*2. Models are also available with robotics (bend resistant) cables . Add “-R” to the model number. (e.g., TL-Q5MC1-R 2M)
1
TL-N/TL-Q
Accessories (Order Separately)
Mounting Brackets A Mounting Bracket is provided with the Sensor depending on the model number. Check the column for the applicable Sensor.
[Refer to Dimensions on page 11.]
Applicable Sensors
Type
Model
Y92E-C5
Provided with these Sensors
Order separately
TL-N5MY@
TL-N5ME@, TL-N7MD@
TL-N10ME@, TL-N12MD@,
TL-N10MF1@
Mounting Brackets
Y92E-C10
TL-N10MY@
Y92E-C20
TL-N20ME@, TL-N20MD@
TL-N20MY@
Y92E-N5C15
Y92E-N10C15
---
---
TL-N5ME@, TL-N5MY@
TL-N10ME@, TL-N10MY@
Mounting Brackets for Conduits
Ratings and Specifications
DC 2-Wire Models
Item
Model
TL-Q5MD@
5 mm 10%
TL-N7MD@
TL-N12MD@
TL-N20MD@
20 mm 10%
0 to 16 mm
Sensing distance
Set distance
7 mm 10%
0 to 5.6 mm
12 mm 10%
0 to 9.6 mm
0 to 4 mm
Differential travel
Detectable object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5.)
Standard sensing
object
Iron, 18 × 18 × 1 mm
Iron, 30 × 30 × 1 mm
Iron, 40 × 40 × 1 mm
Iron, 50 × 50 × 1 mm
Response
frequency *
500 Hz
300 Hz
Power supply voltage
(operating voltage
range)
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current
Load
0.8 mA max.
3 to 100 mA
current
Control
output
Residual
voltage
3.3 V max. (Load current: 100 mA, Cable length: 2 m)
D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
Indicators
Operation mode
(with sensing object
approaching)
D1 Models: NO
D2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.
Protection circuits
Load short-circuit protection, Surge suppressor
Ambient
temperature range
Operating/Storage: −25 to 70°C (with no icing or condensation)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature influence 10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
Voltage influence
Insulation resistance
Dielectric strength
2.5% max. of sensing distance at rated voltage in the rated voltage 15% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
1,000 VAC for 1 min between current-carrying parts and case
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2 3 times
Shock resistance
Destruction: 1,000 m/s2 10 times each in X, Y, and Z directions
each in X, Y, and Z directions
Degree of protection
Connection method
IEC 60529 IP67, in-house standards: oil-resistant
Pre-wired Models (Standard cable length: 2 m)
Weight (packed state) Approx. 85 g
Approx. 165 g
Approx. 235 g
Approx. 330 g
Case
Materials
Heat-resistant ABS
Sensing
surface
Mounting Bracket,
Mounting phillips screws (M4
Instruction manual
Mounting Bracket,
25), Mounting phillips screws (M4
Instruction manual
Mounting Bracket,
30), Mounting phillips screws (M5
Instruction manual
Accessories
Instruction manual
✕
✕
✕ 40),
* The response frequency is an average value.
Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
2
TL-N/TL-Q
DC 3-Wire Models
Item
Model
TL-Q2MC1
TL-Q5MC@/TL-Q5MB1
Sensing
distance
2 mm 15%
0 to 1.5 mm
5 mm 10%
0 to 4 mm
Set distance
Differential travel
Detectable object
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 6.)
Standard
sensing object
Iron, 8 × 8 × 1 mm
Iron, 15 × 15 × 1 mm
Response time
---
2 ms max.
Response
frequency *
500 Hz
Power supply volt-
age (operating volt- 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
age range)
Current
15 mA max. at 24 VDC (no-load)
consumption
10 mA max. at 24 VDC
TL-Q5MC@: NPN open collector,
Load
current
NPN open collector
100 mA max. at 30 VDC max.
50 mA max. at 30 VDC max.
TL-Q5MB@: PNP open collector,
Control
output
50 mA max. at 30 VDC max.
Residual
voltage
1 V max. (under load current of 100 mA with cable length of 1 V max. (under load current of 50 mA with cable length of
2 m)
2 m)
Indicators
Detection indicator (red)
B1/C1 Models: NO
C2 Models: NC
Operation mode
(withsensingobject
approaching)
NO
Refer to the timing charts under DC 3-Wire Models on page 7 for details.
Protection
circuits
Reverse polarity protection, Surge suppressor
Ambient
temperature range
Operating/Storage: −10 to 60°C (with no icing or condensa- Operating/Storage: −25 to 70°C (with no icing or condensa-
tion)
tion)
Ambient
humidity range
Operating/Storage: 35% to 95% (with no condensation)
Temperature
influence
10% max. of sensing distance at 23°C in the temperature
range of −10 to 60°C
20% max. of sensing distance at 23°C in the temperature
range of −25 to 70°C
Voltage
influence
2.5% max. of sensing distance at rated voltage in rated voltage 10% range
Insulation
resistance
50 MΩ min. (at 500 VDC) between current-carrying parts
and case
5 MΩ min. (at 500 VDC) between current-carrying parts and
case
1,000 VAC for 1 min between current-carrying parts and
case
500 VAC, 50/60 Hz for 1 min between current-carrying parts
and case
Dielectric strength
Vibration
resistance
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 1,000 m/s2 10 times each in X, Y, and Z direc- Destruction: 200 m/s2 10 times each in X, Y, and Z direc-
Shock resistance
tions
tions
Degree of
protection
IEC 60529 IP67,
in-house standards: oil-resistant
IEC IP67
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 60 g
Approx. 90 g
Case
Materi-
als
Heat-resistant ABS
Instruction manual
Sensing
surface
Accessories
---
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
3
TL-N/TL-Q
TL-N10ME@, TL-N10MY@,
Item
Model
TL-N5ME@, TL-N5MY@
5 mm 10%
TL-N20ME@, TL-N20MY@
20 mm 10%
0 to 16 mm
TL-N10MF1
Sensing distance
Set distance
10 mm 10%
0 to 8 mm
0 to 4 mm
Differential travel
Detectable object
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on pages 6 and 7.)
Standard
sensing object
Iron, 30 × 30 × 1 mm
Iron, 40 × 40 × 1 mm
Iron, 50 × 50 × 1 mm
Response
frequency *1
E/F Models: 500 Hz
Y Models: 10 Hz
E Models: 40 Hz
Y Models: 10 Hz
Power supply
voltage *2
E/F Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
(operating voltage Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
range)
Current
consumption
E/F Models: 8 mA max. at 12 VDC, 15 mA max. at 24 VDC
Leakage current
Y Models: Refer to Engineering Data on page 5.
Load
current
E/F Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
Control
output
Residual E/F Models: 1 V max. (load current: 200 mA)
voltage
Y Models: Refer to Engineering Data on page 5.
E/F Models: Detection indicator (red)
Y Models: Operation indicator (red)
Indicators
E1/F1/Y1 Models: NO
E2/Y2 Models: NC
Operation mode
(with sensing ob-
ject approaching)
Refer to the timing charts under I/O Circuit Diagrams on page 7 for details.
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Protection circuits
Ambient
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
temperature range
Ambient
humidity range
Temperature
influence
10% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
E/F Models: 2.5% max. of sensing distance at rated voltage in rated voltage 10% range
Y Models: 1% max. of sensing distance at rated voltage in rated voltage 10% range
Voltage influence
Insulation
resistance
50 MΩ min. (at 500 VDC) between current-carrying parts and case
E/F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Dielectric strength
Vibration
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s2 10 times each in X, Y, and Z directions
resistance
Shock resistance
Degree of
protection
IEC 60529 IP67, in-house standards: oil-resistant
Connection
method
Pre-wired Models (Standard cable length: 2 m)
Weight
(packed state)
Approx. 190 g
Approx. 240 g
Approx. 340 g
Case
Materi-
als
Heat-resistant ABS
Sensing
surface
E Models: Mounting Bracket,
E Models: Mounting Bracket,
E/F Models: Mounting Bracket,
Mounting phillips screws (M4 ✕ 30),
Mounting phillips screws (M5
✕ 40),
Mounting phillips screws (M4
✕
25),
Accessories
Instruction manual
Instruction manual
Instruction manual
Y Models: Instruction manual
Y Models: Instruction manual
Y Models: Instruction manual
*1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
a set distance of half the sensing distance.
*2. E Models (DC switching models): A full-wave rectification power supply of 24 VDC 10% (average value) can be used.
4
TL-N/TL-Q
Engineering Data (Reference Value)
Sensing Area
TL-Q2MC1
TL-Q5M@@
TL-N@ME@
TL-N@MY@
Y
X
5
4
3
2
1
0
TL-N20
20
4
3
2
1
0
15
Y
X
TL-N10
10
TL-N5
Y
X
5
0
−8
−6
−4
−2
0
2
4
6
−8 −6 −4 −2
0
2
4
6
8
−25 −20 −15 −10 −5
0
5
10 15 20
TL-N5 Sensing Head
TL-N10 Sensing Head
TL-N20 Sensing Head
Distance Y (mm)
Distance Y (mm)
Sensing Head
Sensing Head
Distance Y (mm)
Leakage Current
TL-N@MD@
TL-N@MY
TL-N20MD@
2.0
1.5
1.0
0.5
20
15
TL-N12MD@
10
Protective resistance
mA
TL-N7MD@
Y
X
AC
power
50/60
Hz
5
V
Proximity Sensor
(output OFF)
0
0
80 100 120 140 160 180 200 220 240 260
Power supply voltage (V)
-25 -20 -15 -10
-5
0
5
10 15 20
TL-N7MD@ Sensing Head
Distance Y (mm)
TL-N12MD@ Sensing Head
TL-N20MD@ Sensing Head
Residual Output Voltage
TL-N@MD
TL-N@MY at 100 VAC
TL-N@MY at 200 VAC
5
Residual output voltage
Residual output voltage
100
200
160
120
80
4
3
2
1
ON
ON
80
60
V
V
200 VAC
100 VAC
A
A
40
40
20
Residual
Residual
load voltage
load
voltage
OFF
100 200
Load current (mA)
OFF
30 50 100 200
Load current (mA)
0
3
5
10 20
50
0
3
5
10 20
0
3
5
10
30 50 100
300 500 1,000
Load current (mA)
5
TL-N/TL-Q
Sensing Object Size vs. Sensing Distance
TL-Q5MC@
7
t = 1 mm
6
5
d ×
d
4
X
3
2
1
0
10
20
30
40
Side length of sensing object: d (mm)
Influence of Sensing Object Size and Material
TL-Q2MC1
TL-Q5M@@
TL-N5@
4
6
d ×
d ×
d
d
d ×
t = 1 mm
d
6
5
4
3
2
1
X
X
5
X
Iron
3
2
1
Iron
4
3
2
1
Stainless steel
(SUS304)
Iron
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Brass
Brass
Aluminum
Copper
Aluminum
Aluminum
Brass
0
10
20
30
40
50
60 70
80
0
10
20
30
40
50
60
0
5
10
15
20
25
30 35
40 45
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
TL-N7MD@
TL-N12MD@
TL-N20MD@
10
14
24
d ×
d ×
d ×
d
d
d
t = 1 mm
t = 1 mm
Iron
t = 1 mm
12
10
8
X
X
Iron
X
20
16
12
8
8
Iron
6
4
2
Stainless steel
(SUS304)
Stainless steel
(SUS304)
Stainless steel
(SUS304)
6
Brass
Brass
Brass
Copper
Aluminum
Copper
Aluminum
4
Aluminum
Copper
4
2
0
10
20
30
40
50
60
0
10
20
30
40
50
60
0
10
20
30
40
50
60
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
6
TL-N/TL-Q
TL-N10@
TL-N20@
d ×
d ×
22
d
d
t = 1 mm
t = 1 mm
Iron
Iron
X
X
10
8
20
18
16
14
12
10
8
6
Stainless steel
(SUS304)
Stainless steel
(SUS304)
4
Brass
Brass
6
Aluminum
Aluminum
2
4
2
0
10
20
30
40
50
60 70
80
0
10
20
30
40
50
60 70
80
Side length of sensing object: d (mm)
Side length of sensing object: d (mm)
I/O Circuit Diagrams
Operation
Output
configuration
Model
mode
Timing chart
Output circuit
Set position
Stable sensing
area
Unstable
sensing
area
Non-sensing
area
Proximity Sensor
Sensing
object
TL-Q5MD1
TL-N7MD1
TL-N12MD1
TL-N20MD1
(%)
100 80 (TYP)
0
NO
Rated
sensing
distance
ON
OFF
Setting indicator
(green)
Brown
ON
Load
Operation indicator
(red)
+V
OFF
ON
Proximity
Sensor
main
Control output
OFF
DC 3-wire,
NPN
circuit
Sensing
area
Non-sensing
area
Blue
0 V
Proximity Sensor
Note: The load can be connected to either
the +V or 0 V side.
Sensing
object
TL-Q5MD2
TL-N7MD2
TL-N12MD2
TL-N20MD2
(%)
100
0
NC
Rated
sensing
distance
ON
Operation indicator
(red)
OFF
ON
Control output
OFF
7
TL-N/TL-Q
Operation
mode
Output
configuration
Model
Timing chart
Output circuit
Present
Not present
ON
Sensing object
Brown
TL-Q2MC1
TL-Q5MC1
+V
Output transistor
(load)
NO
NC
100 Ω
OFF
Load
Proximity
Sensor
main
ON
Detection indicator
(red)
*
Black
OFF
DC 3-wire,
NPN
Output
circuit
Present
Not present
ON
Sensing object
Blue
0 V
Output transistor
(load)
TL-Q5MC2
* Load current: 100 mA max., TL-Q2MC1
Load current: 50 mA max., TL-Q5MC1
OFF
ON
Detection indicator
(red)
OFF
Brown
+V
Present
Not present
ON
Sensing object
Proximity
Sensor
main
Black
DC 3-wire,
PNP
Output transistor
(load)
TL-Q5MB1
NO
Output
*
circuit
OFF
Load
ON
Detection indicator
(red)
OFF
Blue
0 V
* Load current: 50 mA max.
Present
Not present
Operate
Reset
Sensing object
Load (between brown
and black leads)
TL-N5ME1
TL-N10ME1
TL-N20ME1
Brown
+V
NO
100 Ω
High
Output voltage (between
black and blue leads)
Load
Low
4.7 kΩ
ON
Proximity
Sensor
main
*1
Detection indicator (red)
Black
OFF
DC 3-wire,
NPN
2.2 Ω
Output
*2
circuit
Tr
Present
Not present
Operate
Sensing object
Blue
0 V
Load (between brown
and black leads)
TL-N5ME2
TL-N10ME2
TL-N20ME2
Reset
*1. Load current: 200 mA max.
NC
High
Low
ON
Output voltage (between
black and blue leads)
*2. When a transistor is connected.
Detection indicator (red)
OFF
Brown
+V
Present
Not present
Operate
Reset
Sensing object
Tr
Proximity
Sensor
main
*2
2.2 Ω
4.7 kΩ
Black
Load (between black
and blue leads)
DC 3-wire,
PNP
Output
TL-N10MF1
NO
circuit
Output voltage (between
brown and black leads)
High
*1
Load
Low
100 Ω
Blue
ON
0 V
Detection indicator (red)
OFF
*1. Load current: 200 mA max.
*2. When a transistor is connected.
Present
Sensing object
Load
Not present
Operate
Reset
TL-N5MY1
TL-N10MY1
TL-N20MY1
NO
NC
Brown
Load
ON
Operation indicator (red)
Proximity
Sensor
main
OFF
AC 2-wire
circuit
Present
Not present
Operate
Reset
Sensing object
Load
TL-N5MY2
TL-N10MY2
TL-N20MY2
Blue
ON
Operation indicator (red)
OFF
8
TL-N/TL-Q
Safety Precautions
Refer to Warranty and Limitations of Liability.
WARNING
This product is not designed or rated for ensuring
safety of persons either directly or indirectly.
Do not use it for such purposes.
• Do not short-circuit the load, otherwise the Sensor may
be damaged.
• Do not supply power to the Sensor with no load,
otherwise the Sensor may be damaged.
Applicable Models: AC 2-Wire Models
Precautions for Correct Use
Do not use this product under ambient conditions that exceed the
ratings.
● Design
Influence of Surrounding Metal
Mutual Interference
When mounting the Sensor within a metal panel, ensure that the
clearances given in the following table are maintained. Failure to
maintain these distances may cause deterioration in the performance
of the Sensor.
When installing Sensors face-to-face or side-by-side, ensure that the
minimum distances given in the following table are maintained.
Face-to-face
Parallel
A
TL-N*2
Rectangular Models
TL-Q
B*1
B
B*1
A
Mutual Interference (Unit: mm)
A
Model
Distance
A *
B *
TL-Q5MC@, TL-Q5MB1
TL-Q5MD@
TL-N7MD@
TL-N12MD@
TL-N20MD@
TL-N5ME@
TL-N5MY@
TL-N10ME@, TL-N10MF1, TL-N10MY@
TL-N20ME@, TL-N20MY@
60 (17)
60 (30)
120 (60)
120 (80)
120 (60)
200 (100)
Influence of Surrounding Metal (Unit: mm)
Model
Distance
A
B *1
20
35
40
60
23
30
45
100 (50)
120 (60)
TL-Q5M@@, TL-Q5MB1
TL-N7MD@
TL-N12MD@
TL-N20MD@
TL-N5ME@, TL-N5MY@
20
40
50
70
20
40
80
200 (100) 300 (150)
80 (40)
80 (40)
80 (40)
90 (40)
120 (60)
200 (100)
120 (60)
120 (60)
TL-N10ME@, TL-N10MF1, TL-N10MY@
TL-N20ME@, TL-N20MY@
* Values in parentheses apply to Sensors operating at different frequencies.
*1. The B dimension applies to the top, right-side, and left-side surfaces.
*2. The values for A or B for the TL-N apply when there is metal on only one side
of the sensor. If there is metal on two or more sides of the sensor, the value
must be multiplied by two or more.
A
B
B
A
TL-Q2MC1
Mutual Interference (Unit: mm)
Mounting plate*
TL-Q2MC1
* The mounting plate
Model
Distance
A *
30 (8)
B *
90 (45)
B
must be a non-
ferrous metal.
3 mm
TL-Q2MC1
* Values in parentheses apply to Sensors operating at different frequencies.
Influence of Surrounding Metal (Unit: mm)
Model
Distance
A
B
TL-Q2MC1
12
3
● Mounting
When tightening the mounting screws, do not exceed the torque in the
following table.
Model
TL-Q2MC1
TL-Q5M@@
TL-N@M@@
Torque
0.59 N·m
0.9 to 1.5 N·m
9
TL-N/TL-Q
(Unit: mm)
Dimensions
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
Sensors
TL-Q2MC1
1
*
6
Detection indicator (red)
Sensing surface
3.2-dia. mounting hole
0.2
18.5
8
8
2.5
9
25
28
* 2.9-dia. vinyl-insulated round cable with 3 conductors
(Conductor cross section: 0.15 mm2, Insulator diameter:
0.9 mm), Standard length: 2 m
32 max.
TL-Q5M@@
28
3.5
*1
Mounting Hole
Dimensions
17
0.1
17
10.5
0.1
10.5
Two, 3.3 dia.
Indicators *2
Two, 3.3-dia. holes
16
3
*1. B/C Models: 4-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.2 mm2,
Insulator diameter: 1.2 mm), Standard length: 2 m
D Models: 4-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.3 mm2,
Insulator diameter: 1.3 mm), Standard length: 2 m
*2. B/C Models: Detection indicator (red)
D Models: Operation indicator (red), Setting indicator (green)
TL-N7MD@, TL-N5ME@
Two, 4.3 dia.
35
0.45
18
25
8 dia. 9 dia.
Indicator *2
6
23.8
Rubber bushing
Mounting Hole Dimensions
25
Two, 4.5-dia. or M4 holes
18.5
*1
18.5
38.5
0.5
0.2
18
1.5
*1. D Models: 6-dia. vinyl-insulated round cable with 2 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
E Models: 6-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red), Setting indicator (green)
D2 Models: Operation indicator (red)
E Models: Detection indicator (red)
TL-N5MY@
TL-N12MD@,
TL-N10ME@,
TL-N10MY@
0.1
Two, 4.3 dia.
49
Two, 4.3 dia.
46.3
30
0.45
22
8 dia. 9 dia.
0.45
25
18
35.8
Indicator *2
7.7
8 dia. 9 dia.
Operation indicator (red)
6.2
0.5
34.1
Mounting Hole Dimensions
Mounting Hole
Dimensions
Rubber bushing
30
21.5
Rubber bushing
Two, 4.5-dia. or M4 holes
25
*1
Two, 4.5-dia. or M4 holes
18.5
18.5
52.5
1.5
0.5
*
18.5
1.5
0.2
18
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 2 m
E/Y Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red) and Setting indicator (green)
D2 Models: Operation indicator (red)
50
0.2
22
* 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator diameter:
1.9 mm), Standard length: 2 m
E/Y Models: Detection indicator (red)
Y Models: Operation indicator (red)
10
TL-N/TL-Q
TL-N20MD@, TL-N20ME@, TL-N20MY@
Mounting Hole Dimensions
47
Two, 5.5 dia.
Two, 5.5-dia. or M5 holes
0.45
10 dia. 12 dia.30
40
0.2
30
Indicator *2
8
31.8
*1. D/Y Models: 6-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.5 mm2, Insulator
diameter: 1.9 mm), Standard length: 2 m
E Models: 6-dia. vinyl-insulated round cable with 3
conductors (Conductor cross section: 0.5 mm2,
Insulator diameter: 1.9 mm), Standard length: 2 m
*2. D1 Models: Operation indicator (red) and Setting indicator (green)
D2 Models: Operation indicator (red)
Rubber bushing
*1
40
30
53
25
1
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
Accessories (Order Separately)
Mounting Bracket
Y92E-C20
Y92E-C5
Y92E-C10
Two, M4
3.5
34
Two, M4
32
Two, M5
35
20
18
4
20
19.5
6
5.5
4.5
2.3
4.5
*1
12
0.2
18
25
0.2
0.2
0.2
30
40
*1 22
0.2
0.2
30
*1 16
22
9
6.5
9.5
7
2.3
14.5
3.2
24
Applicable Models: TL-N5ME@ *2
Applicable Models: TL-N5MY@
Applicable Models: TL-N7MD@ *2
Material: Mounting Bracket: Zinc-plated iron
Mounting Pan-head Phillips Screws:
Nickel-plated iron
Applicable Models: TL-N10ME@ *2
Applicable Models: TL-N10MY@
Applicable Models: TL-N12MD@ *2
Material: Mounting Bracket: Zinc-plated iron
Mounting Pan-head Phillips Screws:
Nickel-plated iron
Applicable Models: TL-N20ME@ *2
Applicable Models: TL-N20MY@
Applicable Models: TL-N20MD@ *2
Material: Mounting Bracket: Zinc-plated iron
Mounting Pan-head Phillips Screws:
Nickel-plated iron
(Size: M4, Length: 25 mm)
(Size: M4, Length: 30 mm)
(Size: M5, Length: 40 mm)
*1. These are the mounting dimensions of the base of the Mounting Bracket.
*2. Provided with the product.
Mounting Brackets for Wiring Conduit Use (Sold Separately)
Y92E-N10C15
Y92E-N5C15
30
25
0.3
22
13
Two, 4.3 dia.
3.5
0.3
18
11
Two, 4.3 dia.
3.5
0.2
0.2
21
2.3
18
2.3
5.5
24.3
2.3
5
23.8
2.3
C15 conduit screw, JIS-B-0204
C15 conduit screw, JIS-B-0204
Applicable Models: TL-N10ME@
Applicable Models: TL-N10MY@
Applicable Models: TL-N12MD@
Material: Zinc-plated iron
Applicable Models: TL-N5ME@
Applicable Models: TL-N5MY@
Applicable Models: TL-N7MD@
Material: Zinc-plated iron
11
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2017.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2017 All Right Reserved.