Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W; 输出电压的变化多种多样: 48 V 15至150瓦,以及5或12 V为150瓦
S8JX-G03505C
型号: S8JX-G03505C
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
输出电压的变化多种多样: 48 V 15至150瓦,以及5或12 V为150瓦

文件: 总28页 (文件大小:2335K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
New Product  
Switch Mode Power Supply  
S8JX (15/35/50/100/150/300/600-W Models)  
Wide Variety of Output Voltage  
Variations: 48 V for 15 to 150 W,  
and 5 or 12 V for 150 W  
• Easy Mounting:  
Mounting Bracket provided as a standard feature.  
(except for DIN Rail-mounting models)  
Mounts to DIN Rail. (except 600-W model)  
Screw-mount at the top. (except 300-/600-W models)  
• Safety standards:  
UL 508/60950-1  
cUL CSA C22.2 No. 107.1  
cUR CSA C22.2 No. 60950-1  
EN 50178 (= VDE 0160)  
EN 60950-1 (= VDE 0805 Teil 1)  
• EMC: Conforms to EN 61204-3 Class A.  
EMI: EN55011  
(
)
EMS: EN61000-4  
• Input conditions:  
The input voltage range of 15-W, 35-W,  
50-W, 100-W, and 150-W models has been  
increased to 80 to 370 VDC (EC Directives  
and safety standards do not apply.).  
Note: Refer to Safety Precautions on page 24.  
Model Number Structure  
Model Number Legend  
Note: 1. Not all combinations are possible. Refer to List of Models in Ordering Information on page 2.  
2. Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for  
details.  
15-/35-/50-/100-/150-W Models  
3. Configuration (15/35/50/100/150 W model)  
S8JX-G@@@@@@@  
None: Open-frame  
C: Covered  
4. Configuration/mounting  
None: Front-mounting  
D: DIN Rail-mounting  
1
2
3 4  
1. Power Ratings  
015: 15 W  
035: 35 W  
050: 50 W  
100: 100 W  
150: 150 W  
2. Output Voltage  
05: 5 V  
12: 12 V  
15: 15 V  
24: 24 V  
48: 48 V  
300-/600-W Models  
2. Output Voltage  
S8JX-G@@@@@@  
24: 24 V  
3. Configuration/mounting (covered type)  
C: Front-mounting  
1
2
3
1. Power Ratings  
300: 300 W  
600: 600 W  
CD: DIN Rail-mounting  
Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for  
details.  
1
S8JX  
Ordering Information  
List of Models  
Note: For details on normal stock models, contact your nearest OMRON representative.  
Configuration  
Input voltage  
Power ratings Output voltage (VDC)  
Output current  
3 A  
Model  
S8JX-G01505  
S8JX-G01512  
S8JX-G01515  
S8JX-G01524  
S8JX-G01548  
S8JX-G03505  
S8JX-G03512  
S8JX-G03515  
S8JX-G03524  
S8JX-G03548  
S8JX-G05005  
S8JX-G05012  
S8JX-G05024  
S8JX-G05048  
S8JX-G10005  
S8JX-G10012  
S8JX-G10024  
S8JX-G10048  
S8JX-G15005  
S8JX-G15012  
S8JX-G15024  
S8JX-G15048  
S8JX-G01505D  
S8JX-G01512D  
S8JX-G01515D  
S8JX-G01524D  
S8JX-G01548D  
S8JX-G03505D  
S8JX-G03512D  
S8JX-G03515D  
S8JX-G03524D  
S8JX-G03548D  
S8JX-G05005D  
S8JX-G05012D  
S8JX-G05024D  
S8JX-G05048D  
S8JX-G10005D  
S8JX-G10012D  
S8JX-G10024D  
S8JX-G10048D  
S8JX-G15005D  
S8JX-G15012D  
S8JX-G15024D  
S8JX-G15048D  
5 V  
12 V  
1.3 A  
1 A  
15 W  
35 W  
15 V  
24 V  
48 V  
5 V  
0.65 A  
0.35 A  
7 A  
12 V  
15 V  
24 V  
48 V  
5 V  
3 A  
2.4 A  
1.5 A  
0.75 A  
10 A  
Front-mounting *1  
12 V  
24 V  
48 V  
5 V  
4.2 A  
2.1 A  
1.1 A  
20 A  
50 W  
100 W  
150 W  
12 V  
24 V  
48 V  
5 V  
8.5 A  
4.5 A  
2.1 A  
30 A  
100 to 240 VAC  
(free)  
12 V  
24 V  
48 V  
5 V  
13 A  
6.5 A  
3.3 A  
3 A  
(80 to 370 VDC *3)  
S8JX-G15005@:  
Switchable between  
100 to 120 VAC and  
200 to 240 VAC. (DC  
power cannot be  
input.)  
Open-frame Power  
Supplies  
12 V  
15 V  
24 V  
48 V  
5 V  
1.3 A  
1 A  
15 W  
35 W  
0.65 A  
0.35 A  
7 A  
12 V  
15 V  
24 V  
48 V  
5 V  
3 A  
2.4 A  
1.5 A  
0.75 A  
10 A  
DIN Rail-mounting *2  
12 V  
24 V  
48 V  
5 V  
4.2 A  
2.1 A  
1.1 A  
20 A  
50 W  
100 W  
150 W  
12 V  
24 V  
48 V  
5 V  
8.5 A  
4.5 A  
2.1 A  
30 A  
12 V  
24 V  
48 V  
13 A  
6.5 A  
3.3 A  
*1. The front-mounting bracket is included as standard with the product.  
*2. A front-mounting bracket is not included with the product.  
*3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
2
S8JX  
Configuration  
Input voltage  
Power ratings Output voltage (VDC)  
Output current  
3 A  
Model  
5 V  
S8JX-G01505C  
S8JX-G01512C  
S8JX-G01515C  
S8JX-G01524C  
S8JX-G01548C  
S8JX-G03505C  
S8JX-G03512C  
S8JX-G03515C  
S8JX-G03524C  
S8JX-G03548C  
S8JX-G05005C  
S8JX-G05012C  
S8JX-G05024C  
S8JX-G05048C  
S8JX-G10005C  
S8JX-G10012C  
S8JX-G10024C  
S8JX-G10048C  
S8JX-G15005C  
S8JX-G15012C  
S8JX-G15024C  
S8JX-G15048C  
S8JX-G01505CD  
S8JX-G01512CD  
S8JX-G01515CD  
S8JX-G01524CD  
S8JX-G01548CD  
S8JX-G03505CD  
S8JX-G03512CD  
S8JX-G03515CD  
S8JX-G03524CD  
S8JX-G03548CD  
S8JX-G05005CD  
S8JX-G05012CD  
S8JX-G05024CD  
S8JX-G05048CD  
S8JX-G10005CD  
S8JX-G10012CD  
S8JX-G10024CD  
S8JX-G10048CD  
S8JX-G15005CD  
S8JX-G15012CD  
S8JX-G15024CD  
S8JX-G15048CD  
S8JX-G30024C  
S8JX-G60024C  
S8JX-G30024CD  
12 V  
1.3 A  
1 A  
15 W  
35 W  
15 V  
24 V  
48 V  
5 V  
0.65 A  
0.35 A  
7 A  
12 V  
15 V  
24 V  
48 V  
5 V  
3 A  
2.4 A  
1.5 A  
0.75 A  
10 A  
Front-mounting *1  
12 V  
24 V  
48 V  
5 V  
4.2 A  
2.1 A  
1.1 A  
20 A  
50 W  
100 W  
150 W  
12 V  
24 V  
48 V  
5 V  
8.5 A  
4.5 A  
2.1 A  
30 A  
100 to 240 VAC  
(free)  
12 V  
24 V  
48 V  
5 V  
13 A  
6.5 A  
3.3 A  
3 A  
(80 to 370 VDC *3)  
S8JX-G15005@@:  
Switchable between  
100 to 120 VAC and  
200 to 240 VAC. (DC  
power cannot be  
input.)  
Covered Power  
Supplies  
12 V  
15 V  
24 V  
48 V  
5 V  
1.3 A  
1 A  
15 W  
35 W  
0.65 A  
0.35 A  
7 A  
12 V  
15 V  
24 V  
48 V  
5 V  
3 A  
2.4 A  
1.5 A  
0.75 A  
10 A  
DIN Rail-mounting *2  
12 V  
24 V  
48 V  
5 V  
4.2 A  
2.1 A  
1.1 A  
20 A  
50 W  
100 W  
150 W  
12 V  
24 V  
48 V  
5 V  
8.5 A  
4.5 A  
2.1 A  
30 A  
12 V  
24 V  
48 V  
13 A  
6.5 A  
3.3 A  
14 A  
300 W  
600 W  
300 W  
100 to 120 VAC  
200 to 240 VAC  
(Swichable)  
Front-mounting *1  
24 V  
27 A  
DIN Rail-mounting *2  
14 A  
*1. The front-mounting bracket is included as standard with the product.  
*2. A front-mounting bracket is not included with the product.  
*3. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
3
S8JX  
Ratings, Characteristics, and Functions  
Input specification  
100 to 240 V input  
Item  
Power ratings *1  
15 W  
35 W  
Efficiency  
68% min.  
73% min.  
100 to 240 VAC (allowable range: 85 to 264 VAC)  
Voltage *2  
80 to 370 VDC *9  
Note: This range is not applicable for the safety standards.  
Frequency *2  
Current *3  
50/60 Hz (47 to 450 Hz)  
100 V input  
200 V input  
0.4 A max.  
1 A max.  
0.25 A max.  
0.6 A max.  
Power factor  
---  
---  
Input  
Harmonic current emissions  
100 V input  
0.5 mA max.  
1 mA max.  
20 A max.  
40 A max.  
Yes  
Leakage current *3  
200 V input  
100 V input  
200 V input  
Inrush current (for a  
cold start at 25°C) *3  
Noise filter  
Voltage adjustment range *5  
Ripple *3  
10% to 15% (with V. ADJ) (48-V models: 10%)  
2% (p-p) max.  
Input variation influence  
0.4% max. with AC input voltage  
Output *4 Load variation influence  
Temperature variation influence  
Startup time  
0.8% max. (0 to 100% load, rated input voltage)  
0.05%/°C max. (at rated input and output)  
500 ms max. (up to 90% of output voltage at rated input and output)  
Hold time *3  
20 ms min.  
Overload protection *6  
Overvoltage protection *7  
105% to 175% of rated load current, voltage drop, intermittent, automatic reset  
Yes  
Overheat protection  
No  
Additional  
functions  
Parallel operation  
No  
Series operation  
Yes (For up to two Power Supplies; external diodes required.)  
No  
Protective circuit operation indicator  
Refer to the derating curve in Engineering Data on page 13 (with no icing or  
condensation).  
Ambient operating temperature  
Storage temperature  
25 to 65°C (with no icing or condensation)  
Ambient operating humidity  
25% to 85% (Storage humidity: 25% to 90%)  
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)  
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)  
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)  
Dielectric strength  
Insulation resistance  
Vibration resistance  
Shock resistance  
Output indicator  
100 Mmin. (between all outputs and all inputs/PE terminals) at 500 VDC  
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions  
150 m/s2, 3 times each in X, Y, Z directions  
Yes (Color: Green)  
Conducted Emissions  
Radiated Emissions  
Electrostatic Discharge  
Conforms to EN 55011 Group 1 Class A and based on FCC Class A  
Conforms to EN 55011 Group 1 Class A  
EMI  
Other  
Confirms to EN61000-4-2  
Radiated Electromagnetic Field Confirms to EN61000-4-3  
Electrical Fast Transient/Burst  
Surge  
Confirms to EN61000-4-4  
Confirms to EN61000-4-5  
Confirms to EN61000-4-6  
EMS  
Conducted Disturbance  
Voltage Dips/Short Interruptions Confirms to EN61000-4-11  
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)  
cUL Listed: CSA C22.2 No.107.1  
cUR: CSA C22.2 No. 60950-1  
Approved standards *9  
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)  
(Terminal block: Based on DIN 50274 (VDE 0660-514))  
SEMI  
SEMI F47-0200 (200-VAC input)  
250 g max.  
Weight *8  
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not  
start. Refer to Overload Protection on page 15.  
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal  
temperature of the Power Supply may result in ignition or burning.  
*3. Rated input voltage: 100 or 200 VAC at 100% load.  
*4. Output characteristics: Specified at power supply output terminals.  
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output  
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.  
*6. For details, refer to Overload Protection on page 15.  
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.  
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.  
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
4
S8JX  
Input specification  
100 to 240 V input  
Item  
Power ratings *1  
50 W  
100 W  
Efficiency  
76% min.  
100 to 240 VAC (allowable range: 85 to 264 VAC)  
Voltage *2  
80 to 370 VDC *9  
Note: This range is not applicable for the safety standards.  
Frequency *2  
Current *3  
50/60 Hz (47 to 450 Hz)  
100 V input  
200 V input  
1.4 A max.  
0.8 A max.  
2.5 A max.  
1.5 A max.  
Power factor  
---  
---  
Input  
Harmonic current emissions  
100 V input  
0.5 mA max.  
1 mA max.  
20 A max.  
40 A max.  
Yes  
Leakage current *3  
200 V input  
100 V input  
200 V input  
Inrush current (for a  
cold start at 25°C) *3  
Noise filter  
Voltage adjustment range *5  
Ripple *3  
10% to 15% (with V. ADJ) (48-V models: 10%)  
2% (p-p) max.  
Input variation influence  
0.4% max. (with AC input voltage)  
0.8% max. (0 to 100% load, rated input voltage)  
0.05%/°C max. (at rated input and output)  
Output *4 Load variation influence  
Temperature variation influence  
Startup time  
500 ms max. (up to 90% of output voltage at rated input and output)  
Hold time *3  
20 ms min.  
Overload protection *6  
Overvoltage protection *7  
105% to 175% of rated load current, voltage drop, intermittent, automatic reset  
Yes  
Overheat protection  
No  
Additional  
functions  
Parallel operation  
No  
Series operation  
Yes (For up to two Power Supplies; external diodes required.)  
No  
Protective circuit operation indicator  
Refer to the derating curve in Engineering Data on page 13 (with no icing or  
condensation).  
Ambient operating temperature  
Storage temperature  
25 to 65°C (with no icing or condensation)  
Ambient operating humidity  
25% to 85% (Storage humidity: 25% to 90%)  
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)  
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)  
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)  
Dielectric strength  
Insulation resistance  
Vibration resistance  
Shock resistance  
Output indicator  
100 Mmin. (between all outputs and all inputs/PE terminals) at 500 VDC  
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions  
150 m/s2, 3 times each in X, Y, Z directions  
Yes (Color: Green)  
Conducted Emissions  
Radiated Emissions  
Electrostatic Discharge  
Conforms to EN 55011 Group 1 Class A and based on FCC Class A  
Conforms to EN 55011 Group 1 Class A  
EMI  
Other  
Confirms to EN61000-4-2  
Radiated Electromagnetic Field Confirms to EN61000-4-3  
Electrical Fast Transient/Burst  
Surge  
Confirms to EN61000-4-4  
Confirms to EN61000-4-5  
Confirms to EN61000-4-6  
EMS  
Conducted Disturbance  
Voltage Dips/Short Interruptions Confirms to EN61000-4-11  
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)  
cUL Listed: CSA C22.2 No.107.1  
cUR: CSA C22.2 No. 60950-1  
Approved standards *9  
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)  
(Terminal block: Based on DIN 50274 (VDE 0660-514))  
SEMI  
SEMI F47-0200 (200-VAC input)  
Weight *8  
300 g max.  
550 g max.  
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not  
start. Refer to Overload Protection on page 15.  
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal  
temperature of the Power Supply may result in ignition or burning.  
*3. Rated input voltage: 100 or 200 VAC at 100% load.  
*4. Output characteristics: Specified at power supply output terminals.  
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output  
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.  
*6. For details, refer to Overload Protection on page 15.  
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.  
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.  
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
5
S8JX  
Input specification  
100/200 V switchable  
150 W at 5 V  
100 to 240 V input  
150 W at 12 V 150 W at 24 or 48 V  
79% min. 85% min.  
Item  
Power ratings *1  
Efficiency  
78% min.  
Switchable between 100 to 100 to 240 VAC (allowable range: 85 to 264 VAC)  
120 VAC (allowable range:  
Voltage *2  
85 to 132 VAC) and 200 to  
240 VAC (allowable range:  
80 to 370 VDC *9  
170 to 264 VAC).  
Frequency *2  
Current *3  
50/60 Hz (47 to 450 Hz)  
100 V input  
200 V input  
3.5 A max.  
2.1 A max.  
---  
3.6 A max.  
2.2 A max.  
3.5 A max.  
2.1 A max.  
Input  
Power factor  
Harmonic current emissions  
---  
100 V input  
0.5 mA max.  
1 mA max.  
20 A max.  
40 A max.  
Yes  
Leakage current *3  
200 V input  
100 V input  
200 V input  
Inrush current (for a  
cold start at 25°C) *3  
Noise filter  
Voltage adjustment range *5  
Ripple *3  
10% to 15% (with V. ADJ) (48-V models: 10%)  
2% (p-p) max.  
Input variation influence  
0.4% max. (with AC input voltage)  
0.8% max. (0 to 100% load, rated input voltage)  
0.05%/°C max. (at rated input and output)  
500 ms max. (up to 90% of output voltage at rated input and output)  
20 ms min.  
Output *4 Load variation influence  
Temperature variation influence  
Startup time  
Hold time *3  
105% to 175% of rated load  
105% to 175% of rated load current, voltage drop,  
current, voltage drop,  
Overload protection *6  
intermittent, automatic reset  
automatic reset  
Overvoltage protection *7  
Overheat protection  
Yes  
Additional  
functions  
No  
Parallel operation  
No  
Series operation  
Yes (For up to two Power Supplies; external diodes required.)  
No  
Protective circuit operation indicator  
Refer to the derating curve in Engineering Data on page 13 (with no icing or  
condensation).  
Ambient operating temperature  
Storage temperature  
25 to 65°C (with no icing or condensation)  
Ambient operating humidity  
25% to 85% (Storage humidity: 25% to 90%)  
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)  
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 mA)  
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 20 mA)  
Dielectric strength  
Insulation resistance  
Vibration resistance  
Shock resistance  
Output indicator  
100 Mmin. (between all outputs and all inputs/PE terminals) at 500 VDC  
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions  
150 m/s2, 3 times each in X, Y, Z directions  
Yes (Color: Green)  
Conducted Emissions  
Radiated Emissions  
Electrostatic Discharge  
Conforms to EN 55011 Group 1 Class A and based on FCC Class A  
Conforms to EN 55011 Group 1 Class A  
EMI  
Other  
Confirms to EN61000-4-2  
Radiated Electromagnetic Field Confirms to EN61000-4-3  
Electrical Fast Transient/Burst  
Surge  
Confirms to EN61000-4-4  
Confirms to EN61000-4-5  
Confirms to EN61000-4-6  
EMS  
Conducted Disturbance  
Voltage Dips/Short Interruptions Confirms to EN61000-4-11  
UL Listed: UL 508 (Listing), UL UR: UL 60950-1 (Recognition)  
cUL Listed: CSA C22.2 No.107.1  
cUR: CSA C22.2 No. 60950-1  
Approved standards *9  
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)  
(Terminal block: Based on DIN 50274 (VDE 0660-514))  
SEMI  
---  
SEMI F47-0200 (200-VAC input)  
700 g max. 600 g max.  
Weight *8  
800 g max.  
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not  
start. Refer to Overload Protection on page 15.  
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal  
temperature of the Power Supply may result in ignition or burning.  
*3. Rated input voltage: 100 or 200 VAC at 100% load.  
*4. Output characteristics: Specified at power supply output terminals.  
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output  
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.  
*6. For details, refer to Overload Protection on page 15.  
*7. To reset the protection, turn OFF the input power for seven minutes or longer and then turn it back ON.  
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.  
*9. The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
6
S8JX  
Input specification  
100/200 V (Selected)  
Item  
Power ratings *1  
300 W  
600 W  
Efficiency  
82% min.  
80% min.  
100 to 120 VAC (allowable range: 85 to 132 VAC)  
200 to 240 VAC (allowable range: 170 to 264 VAC)  
(Switchable)  
Voltage *2  
Frequency *2  
Current *3  
50/60 Hz (47 to 450 Hz)  
100 V input  
200 V input  
8 A max.  
14 A max.  
8 A max.  
---  
---  
4.5 A max.  
Power factor  
Input  
Harmonic current emissions  
100 V input  
0.5 mA max.  
1 mA max.  
Leakage current *3  
200 V input  
100 V input  
200 V input  
25 A max.  
30 A max.  
60 A max.  
Inrush current (for a  
cold start at 25°C) *3  
50 A max.  
Noise filter  
Yes  
Voltage adjustment range *5  
Ripple *3  
10% to 15% (with V. ADJ)  
2% (p-p) max.  
0.4% max.  
Input variation influence  
Output *4 Load variation influence  
Temperature variation influence  
Startup time  
0.8% max. (0 to 100% load, rated input voltage)  
0.05%/°C max.  
650 ms max.  
20 ms min.  
500 ms max.  
Hold time *3  
105% to 175% of rated load current, Inverted  
L voltage drop, the circuit will be shut OFF  
when the overload exceeds 5 s. *9  
105% to 175% of rated load current,  
voltage drop, intermittent, automatic reset  
Overload protection *6  
Overvoltage protection *7  
Yes  
Yes *9  
Yes *9  
Additional  
functions  
Overheat protection  
No  
Parallel operation  
Yes (up to 5 units)  
Series operation  
Yes (For up to two Power Supplies; external diodes required.)  
No Yes (color: red)  
Protective circuit operation indicator  
Ambient operating temperature  
Storage temperature  
Refer to the derating curve in Engineering Data on page 13 (with no icing or condensation).  
25 to 65°C (with no icing or condensation)  
Ambient operating humidity  
25% to 85% (Storage humidity: 25% to 90%)  
3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 25 mA)  
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 25 mA)  
1.0 kVAC for 1 min. (between all outputs and PE terminals; detection current: 25 mA)  
Dielectric strength  
Insulation resistance  
Vibration resistance  
Shock resistance  
Output indicator  
100 Mmin. (between all outputs and all inputs/PE terminals) at 500 VDC  
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions  
150 m/s2, 3 times each in X, Y, Z directions  
Yes (Color: Green)  
Conducted Emissions *3  
Radiated Emissions  
Electrostatic Discharge  
Conforms to EN 55011 Group 1 Class A and based on FCC Class A  
Conforms to EN 55011 Group 1 Class A  
EMI  
Other  
Confirms to EN61000-4-2  
Radiated Electromagnetic Field Confirms to EN61000-4-3  
Electrical Fast Transient/Burst  
Surge  
Confirms to EN61000-4-4  
Confirms to EN61000-4-5  
Confirms to EN61000-4-6  
EMS  
Conducted Disturbance  
Voltage Dips/Short Interruptions Confirms to EN61000-4-11  
UL UR: UL 508 (Recognition), UL UR: UL 60950-1 (Recognition)  
cUL Listed: CSA C22.2 No.107.1  
cUR: CSA C22.2 No. 60950-1  
Approved standards *10  
EN/VDE: EN50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1)  
(Terminal block: Based on DIN 50274 (VDE 0660-514))  
SEMI  
SEMI F47-0200 (200-VAC input)  
Weight *8  
1,600 g max.  
2,500 g max.  
*1. When a load is connected that has a built-in DC-DC converter, the overload protection may operate at startup and the Power Supply may not  
start. Refer to Overload Protection on page 15.  
*2. Do not use an Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal  
temperature of the Power Supply may result in ignition or burning.  
*3. Rated input voltage: 100 or 200 VAC at 100% load.  
*4. Output characteristics: Specified at power supply output terminals.  
*5. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than the allowable voltage range. When adjusting the output  
voltage, confirm the actual output voltage from the Power Supply and be sure that load is not damaged.  
*6. For details, refer to Overload Protection on page 15.  
*7. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON.  
*8. The weight indicated is a for Front-mounting, Open-frame Power Supply.  
*9. The protection-ON alarm indicator will light as soon as the output is interrupted. For resetting, turn OFF the input power, leave for more than  
three minutes , and then turn it back ON again.  
*10.The range for compliance with EC Directives and safety standards (UL, EN, etc.) is 100 to 240 VAC (85 to 264 VAC).  
7
S8JX  
Connections  
Block Diagrams  
S8JX-G01505@@ (15 W)  
S8JX-G01512@@ (15 W)  
S8JX-G01515@@ (15 W)  
S8JX-G01524@@ (15 W)  
AC (L)  
INPUT  
+V  
DC OUTPUT  
V  
Fuse  
2.0 A  
Noise  
filter  
AC (N)  
Rectifier/  
Smoothing circuit  
Inrush current  
protection  
Rectifier  
Smoothing  
circuit  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
S8JX-G01548@@ (15 W)  
AC (L)  
INPUT  
+V  
DC OUTPUT  
V  
Fuse:  
2.0 A  
Noise  
filter  
AC (N)  
Inrush current  
protection  
Rectifier  
Smoothing  
circuit  
Rectifier/  
smoothing circuit  
Drive control  
circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection circuit  
Overvoltage  
detection circuit  
Photocoupler  
S8JX-G03505@@ (35 W)  
S8JX-G03512@@ (35 W)  
S8JX-G03515@@ (35 W)  
S8JX-G03524@@ (35 W)  
AC (L)  
INPUT  
+V  
DC OUTPUT  
V  
Fuse  
3.15 A  
Noise  
filter  
AC (N)  
Rectifier/  
Smoothing circuit  
Inrush current  
protection  
Rectifier  
Smoothing  
circuit  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
S8JX-G03548@@ (35 W)  
AC (L)  
INPUT  
+V  
DC OUTPUT  
V  
Fuse:  
3.15 A  
Noise  
filter  
AC (N)  
Rectifier  
Inrush current  
protection  
Smoothing  
circuit  
Rectifier/  
smoothing circuit  
Drive control  
circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection circuit  
Overvoltage  
detection circuit  
Photocoupler  
8
S8JX  
S8JX-G05005@@ (50 W)  
S8JX-G05012@@ (50 W)  
S8JX-G05024@@ (50 W)  
AC (L)  
INPUT  
+V  
DC OUTPUT  
V  
Fuse  
6.3 A  
Noise  
filter  
AC (N)  
Rectifier/  
Smoothing circuit  
Inrush current  
protection  
Rectifier  
Smoothing  
circuit  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
S8JX-G05048@@ (50 W)  
AC (L  
+V  
DC OUTPUT  
V  
Fuse:  
6.3 A  
Noise  
filter  
INPUT  
AC (N)  
Inrush current  
protection  
Rectifier  
Smoothing  
circuit  
Rectifier/  
smoothing circuit  
Drive control  
circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection circuit  
Overvoltage  
detection circuit  
Photocoupler  
S8JX-G100@@@@ (100 W)  
AC (L)  
INPUT  
AC (N)  
+V  
DC OUTPUT  
V  
Fuse  
8 A  
Noise  
filter  
Smoothing  
circuit  
Inrush current  
protection  
Rectifier  
Rectifier/  
Smoothing circuit  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
9
S8JX  
S8JX-G15005@@ (150 W)  
Rectifier/  
smoothing circuit  
AC (L)  
INPUT  
V  
DC OUTPUT  
V  
Fuse:  
8 A  
Noise  
filter  
AC (N)  
Inrush current protection  
Rectifier/  
smoothing circuit  
Drive control  
circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection circuit  
Overvoltage  
detection circuit  
Photocoupler  
Input voltage switch  
100/200 V switching  
Note: Set the input voltage switch to "115V" for 100 to 120 VAC and to "230V" for 200 to 240 VAC.  
S8JX-G15012@@ (150 W)  
S8JX-G15024@@ (150 W)  
S8JX-G15048@@ (150 W)  
+V  
AC (L)  
INPUT  
AC (N)  
Fuse  
10 A  
Noise  
filter  
DC OUTPUT  
V  
Smoothing  
circuit  
Inrush current  
protection  
Rectifier  
Rectifier/  
Smoothing circuit  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
10  
S8JX  
S8JX-G30024@@ (300 W)  
Rectifier/  
Smoothing circuit  
+V  
AC (L)  
INPUT  
AC (N)  
Fuse  
10 A  
Noise  
filter  
DC OUTPUT  
V  
Inrush current protection  
Rectifier/  
Smoothing circuit  
100/200V (Selectable)  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overvoltage  
detection circuit  
Photocoupler  
Parallel operation selector  
Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC.  
Keep the terminals open if the input is 200 to 240 VAC.  
S8JX-G60024@@ (600 W)  
Rectifier/  
Smoothing circuit  
+V  
AC (L)  
INPUT  
AC (N)  
Fuse  
10 A  
Noise  
filter  
DC OUTPUT  
V  
Inrush current protection  
Rectifier/  
Smoothing circuit  
Fan  
100/200V (Selectable)  
Drive control  
Circuit  
Overcurrent  
detection  
circuit  
Voltage  
detection  
Overheat  
detection  
circuit  
Overvoltage  
detection circuit  
Photocoupler  
Parallel operation selector  
Note: Short-circuit the input voltage selector terminals if the input is 100 to 120 VAC.  
Keep the terminals open if the input is 200 to 240 VAC.  
11  
S8JX  
Construction and Nomenclature  
Nomenclature  
15-/35-/50-/100-/150-W Models  
No.  
Name  
DC Output  
Terminals (V), (+V)  
Function  
D
E
1
Connect the load lines to these terminals.  
D
+V  
E
A
AC Input Terminals  
(L), (N)  
+V  
2
3
4
5
Connect the input lines to these terminals. *1  
Connect the ground line to these terminals. *2  
Use to adjust the voltage.  
V  
A
V  
Protective Earth  
C
B
C
B
Terminal (PE) (  
)
AC (L)  
AC (N)  
AC (L)  
AC (N)  
Output Voltage  
Adjuster (V. ADJ)  
Output Indicator  
(DC ON: Green)  
Lights green while a direct current (DC) output is ON.  
F
Switches the internal circuits according to the input  
voltage.  
"115V": 100 to 120 VAC  
Bottom  
6
Input voltage switch  
"230V": 200 to 240 VAC  
100 to 120 VAC  
200 to 240 VAC  
*1. The fuse is located on the (L) side. It is NOT user-replaceable. For a DC  
power input, connect the low side to the positive (+) terminal.  
*2. This is the protective earth terminal specified in the safety standards.  
Always ground this terminal.  
Note: The S8JX-G05024CD is  
Note: The S8JX-G15005C is shown  
shown above.  
above.  
300-W Model  
600-W Model  
A
FE G  
E
F
AC (L)  
B
V V +V +V  
Side  
+V  
+V  
V  
V  
A
AC (N)  
D
C
H
Bottom  
H
AC (L)  
AC (N)  
D
B
C
No.  
1
Name  
Function  
DC Output Terminals (+V), (V)  
AC Input Terminals (L), (N)  
Connect the load lines to these terminals.  
Connect the input lines to these terminals. *1  
Connect the ground line to these terminals. *2  
2
3
Protective Earth Terminal (PE) (  
Input Voltage Selector Terminals  
Output Indicator (DC ON: Green)  
Output Voltage Adjuster (V. ADJ)  
)
4
Short-circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC.  
Lights while a Direct Current (DC) output is ON.  
5
6
It is possible to increase or decrease the output voltage.  
Protection-ON Alarm Indicator  
(DC ON: Red)  
The red indicator will be lit if the overvoltage (for a 600-W model) or overheat protection (for a 600-W model)  
circuit is triggered. This indicator will also be lit when overload (for a 600-W model) is detected.  
7
8
Selector of Parallel Operation  
Set the selector to PARALLEL if the Units are in parallel operation.  
*1. The fuse is located on the (L) side. It is NOT user-replaceable.  
*2. This is the protective earth terminal specified in the safety standards. Always ground this terminal.  
Reference Values  
S8JX-G15012@@ and S8JX-G15005@@  
Other models  
250,000 hrs  
Reliability (MTBF)  
Definition  
240,000 hrs  
MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device  
failures, and indicates reliability of devices.  
Therefore, it does not necessarily represent a life of the product.  
Life expectancy  
Definition  
10 yrs. min.  
The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%.  
Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor.  
12  
S8JX  
Engineering Data  
Derating Curves (Standard Mounting)  
15-/35-/50-/100-/150-W Models  
Open-frame Power Supplies  
Covered Power Supplies  
120  
120  
100  
80  
100  
80  
A
A
60  
60  
40  
40  
20  
0
20  
0
20 10  
0
10 20 30 40 50 60 70 80  
20 10  
0
10 20 30 40 50 60 70 80  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the  
area shown by shading Ain the above graph).  
2. If there is a derating problem, use forced air-cooling.  
3. For Customers Using a DC Input  
When using an input voltage of less than 100 VDC, reduce the load calculated with the above derating curve by at least the following  
coefficients.  
35-W and 100-W (5-V or 12-V output) models: 0.8  
50-W/150-W models:  
15-W and 100-W (24-V or 48-V output):  
0.85 (DC power cannot be input only to the S8JX-G15005@@.)  
0.9  
300-/600-W Models  
Single Unit Operation  
Parallel Operation  
120  
120  
100  
80  
100  
A
A
80  
60  
40  
60  
Front-mounting,  
Bottom-mounting,  
Solid line  
40  
DIN Rail mounting,  
Side mounting (600W)  
20  
0
20  
0
Dotted line  
Side mounting (300W)  
20 10  
0
10 20 30 40 50 60 70 80  
20 10  
0
10 20 30 40 50 60 70 80  
Ambient Temperature (°C)  
Ambient Temperature (°C)  
Note: 1. Internal parts may occasionally deteriorate or be damaged. Do not use the Power Supply in areas outside the derating curve (i.e., the  
area shown by shading Ain the above graph).  
2. If there is a derating problem, use forced air-cooling.  
13  
S8JX  
Mounting  
15-/35-/50-/100-/150-W Models  
The following three mounting methods are possible.  
A. Front-mounting: Refer to Mounting Bracket Provided with Front-mounting Power Supplies aon page 20.  
B. Bottom-mounting  
C. Side-mounting  
Note: Additional mounting methods are also available using DIN Rail-mounting models.  
B
C
Standard Mounting  
15-/35-/50-/100-/150-W Models  
Front-mounting  
Bottom-mounting  
Vertical Side-mounting  
DIN Rail-mounting  
Horizontal Side-mounting  
*
*
*
*
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts. Use the  
standard mounting method only.  
2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended.  
3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply is designed to radiate heat by  
means of natural air flow.  
300-W Model  
Bottom-mounting  
Side-mounting  
Front-mounting  
20mm min.  
20mm min.  
20mm min.  
20mm min.  
DIN Rail mounting  
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or  
damage of internal parts. Use the standard mounting method only.  
2. When mounting the Power Supply, mounting it to a metal plate (*) is recommended.  
3. Install the Power Supply so that the air flow circulates around the Power Supply, as the Power Supply  
is designed to radiate heat by means of natural air flow.  
600-W Model  
Front-mounting  
Bottom-mounting  
20mm min.  
20mm min.  
20mm min.  
20mm min.  
Side-mounting  
Note: 1. Improper mounting will interfere with heat dissipation and may occasionally  
result in deterioration or damage of internal parts. Use the standard mounting  
method only.  
2. When mounting the Power Supply, mounting it to a metal plate (*) is  
recommended.  
3. Install the Power Supply so that the air flow circulates around the Power  
Supply, as the Power Supply is designed to radiate heat by means of natural  
air flow.  
14  
S8JX  
Overload Protection  
The Power Supply is provided with an overload protection function that protects the power supply from possible damage by overcurrent. When the  
output current rises above 105% to 175% min. of the rated current, the protection function is triggered, decreasing the output voltage. When the  
output current falls within the rated range, the overload protection function is automatically cleared.  
(Reference value)  
15-/35-/50-/100-/150-W (12-/24-/48-V) Models  
600-W Model  
Intermittent operation  
Output interrupted  
0
50  
100  
Load rate (%)  
0
50  
100  
Load rate (%)  
If an excessive current flows for 5 s or more, the output will be turned  
OFF and simultaneously the protection-ON alarm indicator will be lit.  
To reset the S8JX, turn OFF the power, leave the S8JX for at least  
three minutes, and then turn it ON again.  
150-W, 5-V Models  
Note: 1. When a load is connected that has a built-in DC-DC  
converter, the overload protection may operate at startup  
and the power supply may not start.  
2. Internal parts may occasionally deteriorate or be damaged  
if a short-circuited or overcurrent state continues during  
operation.  
3. Internal parts may possibly deteriorate or be damaged if the  
Power Supply is used for applications with frequent inrush  
current or overloading at the load end. Do not use the Power  
Supply for such applications.  
0
50  
100  
Load rate (%)  
300-W Model  
Intermittent operation  
0
50  
100  
Load rate (%)  
15  
S8JX  
Overvoltage Protection  
15-/35-/50-/100-/150-W Models  
Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback  
circuit in the power supply fails. When an excessive voltage that is approximately 130% of the rated voltage or more is output, the output voltage  
is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least seven minutes and then turning  
it back ON again.  
300-/600-W Models  
Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback  
circuit in the Power Supply fails. When an excessive voltage that is approximately 120% of the rated voltage or more is output, the output voltage  
is shut OFF, preventing damage to the load due to overvoltage. Reset the input power by turning it OFF for at least three minute and then turning  
it back ON again.  
(Reference value)  
Overvoltage protection  
Operating  
Rated output  
Voltage  
Variable range  
0 V  
Note: Do not turn ON the power again until the cause of the overvoltage has been removed.  
Overheat Protection  
600-W Model  
If the internal temperature rises excessively as a result of fan failure or any other reason, the overheat protection circuit will be triggered to shut  
OFF the output voltage and simultaneously the protection-ON alarm indicator will be lit. Reset the input power by turning it OFF for at least three  
minutes and then turning it back ON again.  
Inrush Current, Startup Time, Output Hold Time  
Input ON  
Input OFF  
AC input  
voltage  
Inrush current on input application  
AC input  
current  
96.5%  
90%  
Output  
voltage  
Startup time  
Hold time (20 ms min.)  
Note: A maximum startup time of 500 ms is required (650 ms for 300 W). Construct a system configuration that considers the startup time of other  
devices.  
16  
S8JX  
Dimensions  
(Unit: mm)  
Front-mounting Models  
S8JX-G015@@ (15 W)  
S8JX-G015@@C (15 W)  
S8JX-G035@@ (35 W)  
S8JX-G035@@C (35 W)  
5 max.  
3.5  
Panel mounting holes dimensions  
1
10 max.  
90  
Label  
Surface screw mounting  
Two, M3  
8.2  
9.5  
Side  
Mounting  
1
91  
0.5  
75  
0.5  
75  
0.5  
82  
Five, M3.5  
Cover  
3.5 dia.  
Two, M3  
78  
Bottom  
Mounting  
1
35.5  
39.5  
7.5  
0.5  
0.5  
4.5  
8.5  
3.5 dia.  
82  
78  
1
0.5  
3.5  
26.5  
17.5  
Two, M3 (Depth 4 mm max.)  
0.5  
50  
15  
S8JX-G050@@ (50 W)  
S8JX-G050@@C (50 W)  
5 max.  
Panel mounting holes dimensions  
1
100  
10 max.  
Label  
Surface screw mounting  
Two, M3  
3.5  
8.2  
9.5  
0.5  
Side  
75  
0.5  
75  
Mounting  
±1  
92  
0.5  
92  
Five, M3.5  
Cover  
3.5 dia.  
Two, M3  
Bottom  
Mounting  
8
0.5  
0.5  
92  
92  
4.5  
1
1
36  
40  
0.5  
92  
4.5  
3.5 dia.  
3.5  
Two, M3  
(Depth 4 mm max.)  
26.5  
20  
0.5  
20  
65  
S8JX-G100@@ (100 W)  
S8JX-G100@@C (100 W)  
S8JX-G15024 (150 W)  
S8JX-G15024C (150 W)  
S8JX-G15048 (150 W)  
1
150  
150 W  
10 max.  
Panel mounting holes dimensions  
5 max.  
100 W  
100·150 W  
Surface screw mounting  
Label  
S8JX-G15048C (150 W)  
Two, M3  
3.5  
8.2  
9.5  
Side  
Mounting  
0.5  
75  
0.5  
75  
1
92  
Five, M3.5  
Cover  
0.5  
141  
3.5 dia.  
Two, M3  
8
0.5  
141  
141  
5
5
Bottom  
±1  
48  
Mounting  
±1  
50  
0.5  
141  
0.5  
Two, M3  
(Depth 4 mm max.)  
3.5  
3.5 dia.  
28  
0.5  
122  
16  
17  
S8JX  
S8JX-G15005 (150 W)  
S8JX-G15005C (150 W)  
Panel mounting holes dimensions  
Surface screw mounting  
178±1  
5max.  
12max.  
2-M4  
Label  
10  
Two, M3  
3.5  
13  
Side  
Mounting  
8.2  
9.5  
68±0.5  
92±1  
68±0.5  
169±0.5  
Two, M3  
3-M3.5  
3.5 dia.  
Cover  
8
Bottom  
Mounting  
169±0.5  
169±0.5  
60±1  
5
5
169±0.5  
Two, M3  
(Depth: 4 mm max.)  
3.5  
3.5 dia.  
36  
33.5  
140±0.5  
Input voltage switch  
14  
S8JX-G15012 (150 W)  
S8JX-G15012C (150 W)  
Panel mounting holes dimensions  
Surface screw mounting  
Two, M3  
178±1  
5max.  
10max.  
Label  
8.2  
9.5  
3.5  
Side  
Mounting  
68±0.5  
92±1  
68±0.5  
169±0.5  
Two, M3  
3.5 dia.  
5-M3.5  
Cover  
Bottom  
Mounting  
8
169±0.5  
60±1  
5
5
169±0.5  
169±0.5  
Two, M3  
(Depth: 4 mm max.)  
3.5  
3.5 dia.  
36  
33.5  
140±0.5  
14  
18  
S8JX  
S8JX-G30024C (300 W)  
Eight, M4 holes  
(depth: 8 max. on both sides)  
20 max.  
±1  
4 max.  
167.1  
Nine, M4 terminal screws  
Panel mounting holes dimensions  
Surface screw mounting  
Four, 4.5 dia.  
10  
Side  
Mounting  
8.6  
±1  
92  
±0.5  
50  
±0.5  
50  
±0.5  
136  
21  
Four, 4.5 dia.  
±1  
110  
19  
±0.5  
136  
Bottom  
Mounting  
±0.5  
90  
±0.5  
136  
±0.5  
90  
Four, M4 holes  
(depth: 8 max.)  
10  
±0.5  
19  
136  
S8JX-G60024C (600 W)  
Eight, M4 holes  
(depth: 8 max. on both sides)  
±1  
150  
±0.5  
24.4  
8.6 10  
Nine, M4 terminal screws  
±1  
159.8  
±1  
92  
±0.5  
50  
20.9  
±0.5  
124  
8.6 10  
11  
Panel mounting holes dimensions  
Surface screw mounting  
Four, 4.5 dia.  
Four, M4 holes  
(depth: 8 max.)  
Side  
Mounting  
±0.5  
50  
±0.5  
100  
±0.5  
124  
Four, 4.5 dia.  
Bottom  
Mounting  
±0.5  
100  
42  
±0.5  
137  
±0.5  
137  
14.8  
19  
S8JX  
Mounting Bracket Provided with Front-mounting Power Supplies a  
15-/35-/50-/100-/150-W Models  
S82Y-J00F Front-mounting  
Bracket  
Front-mounting Method  
Note: Mounting screws are  
Temporarily attach the enclosed mounting  
bracket as shown in the illustration on the right,  
hook the holes (parts a) in the Power Supply on  
hooks on the mounting bracket (parts b), and  
secure the Power Supply with two mounting  
screws.  
not provided.  
Mounting  
dimensions  
Dimensions  
1.5  
0.2  
4.6 15  
11  
b
9
Two, M3  
a
60  
Mounting bracket  
Two, 3.5 dia.  
Power Supply  
74  
60  
4.6  
b
20  
11  
20  
31.5  
5
4.7  
15  
20.5  
a
t = 1.0  
Material: Stainless steel  
300-/600-W Models  
Front-mounting Bracket (S82Y-J30F)  
Attaching the Mounting Brackets  
Dimensions with  
10 dia.  
Mounting Brackets  
300-W Model  
R2.5  
300-W Model  
30  
15  
7.5  
7.5  
±0.3  
145  
160  
Two, 5 dia.  
92  
t = 1.6  
±0.3  
145  
48  
Note: To provide ventilation space, the body  
will shift forward by 21.6 mm from the  
mounting surface.  
±0.2  
32  
Note: Mounting Brackets are provided in a set, one  
for the right side and one for the left side.  
±0.5  
80  
Four, M4  
600-W Model  
600-W Model  
±0.3  
145  
Note: To provide ventilation space, the body  
will shift forward by 23.6 mm from the  
mounting surface.  
±0.5  
120  
Four, M4  
20  
S8JX  
DIN Rail-mounting Models  
14.5 max.  
S8JX-G015@@D (15 W)  
1
1
90  
10 max.  
44  
6 max.  
S8JX-G015@@CD (15 W)  
S8JX-G035@@D (35 W)  
S8JX-G035@@CD (35 W)  
Label  
5 max.  
8.2  
9.5  
1
91  
Five, M3.5  
Cover  
47  
98.6  
7 (Sliding: 16.6 max.)  
14.5 max.  
S8JX-G050@@D (50 W)  
S8JX-G050@@CD (50 W)  
1
1
100  
44  
10 max.  
6 max.  
Label  
5 max.  
8.2  
9.5  
1
92  
47  
Five, M3.5  
Cover  
1
1
36  
40  
108.6  
7 (Sliding: 16.6 max.)  
S8JX-G100@@D (100 W)  
S8JX-G100@@CD (100 W)  
S8JX-G15024D (150 W)  
S8JX-G15024CD (150 W)  
S8JX-G15048D (150 W)  
S8JX-G15048CD (150 W)  
14.5 max.  
1
150  
150 W  
10 max.  
1
100 W  
50  
6 max.  
Label  
100·150 W  
5 max.  
8.2  
9.5  
1
92  
Five, M3.5  
Cover  
47  
1
158.6  
48  
7 (Sliding: 16.6 max.)  
1
50  
21  
S8JX  
14.5 max.  
S8JX-G15005D (150 W)  
S8JX-G15005CD (15 W)  
6 max.  
2-M4  
60±1  
178±1  
5 max.  
12 max.  
Label  
10  
13  
8.2  
9.5  
92±1  
47  
3-M3.5  
Cover  
7 (Sliding: 16.6 max.)  
186.6  
Input voltage switch  
S8JX-G15012D (150 W)  
S8JX-G15012CD (150 W)  
14.5 max.  
5 max.  
6 max.  
Label  
60±1  
178±1  
10 max.  
8.2  
9.5  
92±1  
47  
5-M3.5  
Cover  
7 (Sliding: 16.6 max.)  
186.6  
22  
S8JX  
S8JX-G30024CD (300 W)  
(17.7)  
Nine, M4 terminal screws  
20 max.  
4 max.  
10.2  
±1  
167.1  
10  
8.6  
±1  
92  
46.6  
4.4 (Sliding: 10 max.)  
4.6 max.  
4.6 max.  
±1  
181.3  
110  
Note: Use a metal DIN Rail when mounting a 300-W model to a DIN Rail.  
DIN Rail (Order Separately)  
Mounting Rail  
(Material: Aluminum)  
0.15  
7.3  
4.5  
Model  
0.3  
0.15  
27  
35  
PFP-100N  
PFP-50N  
15 25  
25  
25  
25  
15 (5) *  
1
10  
10  
1,000 (500) ∗  
* Value in parentheses are for PFP-50N.  
Mounting Rail  
(Material: Aluminum)  
16  
4.5  
0.3  
35  
27 24  
29.2  
1.5  
Model  
PFP-100N2  
15 25  
25  
25  
25 15  
1
10  
10  
1,000  
End Plate  
10  
6.2  
1.8  
M4 × 8  
panhead  
screw  
1
35.5  
35.5  
50  
1.8  
Model  
PFP-M  
11.5  
10  
1.3  
4.8  
M4 spring  
washer  
Note: 1. If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from  
aluminum abrasion.  
2. If the Unit may be subjected to sliding to either side, attach an End Plate (model PFP-M) on each side of the Unit.  
23  
S8JX  
Safety Precautions  
Refer to Safety Precautions for All Power Supplies.  
CAUTION  
Minor electric shock, fire, or Product failure may  
occasionally occur. Do not disassemble, modify, or  
15-/35-/50-/100-/150-W Models  
repair the Product to touch the interior of the  
Product.  
Standard Mounting  
(Front-mounting and DIN Rail-mounting)  
Standard Mounting  
(Bottom-mounting)  
*1  
*1  
Minor burns may occasionally occur. Do not touch  
the Product while power is being supplied or  
immediately after power is turned OFF.  
*1  
Fire may occasionally occur. Tighten terminal screws  
to the specified torque of 1.13 N·m.  
For the 5-V output terminal, tighten the terminal  
screw to 1.56 N·m.  
*2  
*3  
*2  
*1  
Standard Mounting  
(Horizontal Mounting)  
*1  
Minor injury due to electric shock may occasionally  
occur. Do not touch the terminals while power is  
being supplied. Always close the terminal cover after  
wiring.  
*1  
*2  
*3  
300-W Model  
Minor electric shock, fire, or Product failure may  
occasionally occur. Do not allow any pieces of metal  
or conductors or any clippings or cuttings resulting  
from installation work to enter the Product.  
Standard Mounting  
(Front-mounting and DIN Rail-mounting)  
*1  
Precautions for Safe Use  
Mounting  
Take adequate measures to ensure proper heat dissipation to  
increase the long-term reliability of the Product.  
*2  
*1  
Be sure to allow convection in the atmosphere around devices when  
mounting. Do not use in locations where the ambient temperature  
exceeds the range of the derating curve. (except 600 W)  
Standard Mounting  
(Bottom-mounting)  
*1  
The S8JX-@60024@ is designed to radiate heat by means of  
forced air-flow. Do not cover the air holes (provided at fan mounted  
side and the opposite side) to have enough air-cooling.  
The screws must not protrude beyond the following values inside  
the Power Supply when screw holes provided on the chassis are  
used.  
15 W, 35 W, 50 W, 100 W, or 150 W: 4 mm min.  
300 W or 600 W: 8 mm min.  
Mounting screw tightening torque (recommended value) : 0.54 N·m.  
*3  
*2  
Rear mounting is possible using provided mounting bracket.  
When cutting out holes for mounting, make sure that cuttings do  
not enter the interior of the Products.  
600-W Model  
Improper mounting will interfere with heat dissipation and may  
occasionally result in deterioration or damage of internal parts. Use  
the standard mounting method only.  
The internal parts may occasionally deteriorate and be broken due  
to adverse heat radiation. Do not loosen the screw on the side face  
of the main body.  
*1  
*1  
*3  
When mounting two or more Power Supplies side-by-side, allow at  
least 20 mm spacing between them.  
Provide a space of at least 20 mm back and forth when mounting  
300-W and 600-W models as well.  
*1. Convection of air  
*2. 20 mm max.  
*3. Use a metal plate as the mounting surface.  
Use the metal plate as the mounting panel.  
Minor fire may occasionally occur. Set the input voltage switch to  
the input voltage that is to be used (150-W, 5-V models only).  
24  
S8JX  
Wiring  
DIN Rail-mounting  
Connect the ground completely. A protective earthing terminal  
stipulated in safety standards is used. Electric shock or malfunction  
may occur if the ground is not connected completely.  
Minor fire may possibly occur. Ensure that input and output  
terminals are wired correctly.  
Do not apply more than 75 N force to the terminal block when  
tightening it.  
Be sure to remove the sheet covering the Product for machining  
before power-ON so that it does not interfere with heat dissipation.  
Use the following material for the wires to be connected to the  
S8JX to prevent smoking or ignition caused by abnormal loads.  
To mount the Power Supply to a DIN  
Rail, pull down the rail stopper until  
you hear it clicks open, hook portion  
(A) of the Power Supply onto the DIN  
Rail, press the Power Supply in  
direction (B), and then push up the rail  
stopper to lock the Power Supply in  
place.  
(A)  
(B)  
To dismount the Power Supply, pull  
down portion (C) with a flat-blade  
screwdriver and pull out the Power  
Supply.  
Recommended Wire Type  
30 mm min.  
(C)  
Track stopper  
AWG12 to AWG20 (a cross section of 0.517 to  
15 W, 35 W  
3.309 mm2)  
UL-certified temperature of at least 75°C  
Series Operation  
Two power supplies can be connected in series. The ( ) voltage  
output can be accomplished with two Power Supplies.  
AWG12 to AWG16 (a cross section of 1.309 to  
50W, 100W,  
150 W (except  
for 5 V)  
3.309 mm2)  
UL-certified temperature of at least 60°C or  
60/75°C  
Series Operation  
Correct  
Output Voltage ( )  
Correct  
AWG12 to AWG16 (a cross-section of 1.309  
AC (L)  
AC (N)  
+V  
AC (L)  
AC (N)  
+V  
Input  
side  
to 3.309 mm2)  
V  
V  
UL-certified temperature of at least 60°C or  
60/75°C  
150 W  
at 5 V  
AWG8 to AWG14 (a cross-section of 2.081 to  
AC (L)  
AC (N)  
+V  
AC (L)  
AC (N)  
+V  
Output 8.368 mm2)  
side  
V  
V  
UL-certified temperature of at least 60°C or  
60/75°C  
Note: 1. If the load is short-circuited, a reverse voltage will be  
generated inside the Power Supply. If this occurs the Power  
Supply may possibly deteriorate or be damaged. Always  
connect a diode as shown in the figure. Select a diode  
having the following ratings.  
AWG12 to AWG20 (a cross section of 0.517 to  
3.309 mm2)  
UL-certified temperature of at least 60°C or  
60/75°C  
300 W,  
600 W  
Installation Environment  
Type  
Schottky Barrier diode  
Do not use the Power Supply in locations subject to shocks or  
vibrations. In particular, install the Power Supply as far away as  
possible from contactors or other devices that are a vibration  
source.  
Install the Power Supply well away from any sources of strong,  
high-frequency noise and surge.  
Dielectric strength (VRRM)  
Forward current (IF)  
Twice the rated output voltage or above  
Twice the rated output current or above  
2. Although Products having different specifications can be  
connected in series, the current flowing through the load  
must not exceed the smaller rated output current.  
Parallel Operation  
Ambient Operating and Storage Environments  
Store the Power Supply at a temperature of 25 to 65°C and a  
humidity of 25% to 90%.  
The Internal parts may occasionally deteriorate or be damaged.  
Do not use the Power Supply outside the derating range (i.e., the  
area shown by shading Ain the derating curve diagram on  
page 13.)  
Use the Power Supply at a humidity of 25% to 85%.  
Do not use the Power Supply in locations subject to direct sunlight.  
Do not use locations where liquids, foreign matter, or corrosive  
gases may enter the interior of the Product.  
15-/35-/50-/100-/150-W Models  
The Product is not designed for parallel operation.  
Parallel Operation  
Incorrect  
AC (L)  
+V  
AC (N)  
V  
AC (L)  
+V  
AC (N)  
V  
Overload Protection  
Internal parts may possibly deteriorate or be damaged if a short-  
circuited or overload state continues during operation.  
Internal parts may possibly deteriorate or be damaged if the Power  
Supply is used for applications with frequent inrush current or  
overloading at the load end. Do not use the Power Supply for such  
applications.  
300-/600-W Models  
Parallel operation is possible under 80% of the rated value.  
To operate in parallel, set the switch to the "PARALLEL" side.  
The length and thickness of each wire connected to the load must  
be the same so that there is no difference in voltage drop value  
between the load and the output terminals of each Power Supply.  
It is desirable to set the same value on the voltage adjuster of each  
Power Supply.  
Charging a Battery  
When connecting a battery at the load, connect an overcurrent  
limiting circuit and overvoltage protection circuit.  
Parallel Operation  
Correct  
AC (L)  
+V  
Output Voltage Adjuster (V.ADJ)  
The output voltage adjuster (V.ADJ) may possibly be damaged if it  
is turned with unnecessary force. Do not turn the adjuster with  
excessive force.  
AC (N)  
V  
After completing output voltage adjustment, be sure that the output  
capacity or output current does not exceed the rated output  
capacity or rated output current.  
AC (L)  
+V  
AC (N)  
V  
25  
S8JX  
In Case There Is No Output Voltage  
Fan Replacement  
The possible cause for no output voltage may be that the overcurrent  
or overvoltage protection has operated. The internal protection may  
operate if a large amount of surge voltage such as a lightening surge  
occurs while turning ON the Power Supply.  
In case there is no output voltage, please check the following points  
before contacting us:  
600-W Model  
The service life of the fan is approximately 50,000 hours (at 25°C).  
The service life varies, however, depending on the ambient  
temperature or other surrounding environmental conditions such as  
dust. As a preventive maintenance measure, replace the fan within  
approx. two years if it is used at an ambient temperature of 40°C.  
Fans (S82Y-JXFAN) are available as replacements.  
Checking overcurrent protected status:  
Check whether the load is in overcurrent status or is short-  
circuited. Remove wires to load when checking.  
Checking overvoltage or internal protection:  
Turn the power supply OFF once, and leave it OFF for at least  
7 minutes. Then turn it ON again to see if this clears the condition.  
Switching the AC Input Voltage between 100 and 200 VAC  
150-W, 5-V Models  
Fan Set:  
Fan (above), instruction sheet, and packing case  
The input voltage can be switched between 100 V and 200 V by using  
the input voltage switch. Make the setting shown in the following  
figure for the voltage that will be used. (The input voltage is factory-  
set to 200 V.)  
Replace the fan as shown in the following illustration.  
"115V": 100 to 120 VAC  
The input voltage switch is at the back  
on the bottom of the Power Supply.  
"230V": 200 to 240 VAC  
300-/600-W Models  
The input voltage can be switched between 100 and 200 V by shorting  
or opening the input voltage selection terminals. Set the required  
voltage as shown below. (The voltage is factory-set to 200 V.)  
100-V input  
200-V input  
L
L
N
N
VOLTAGE SELECT  
VOLTAGE SELECT  
SHORT 100-120V  
OPEN 200-230V  
SHORT 100-120V  
OPEN 200-230V  
SHORT BAR  
SHORT BAR  
Short with the short bar.  
Remove the short bar  
and leave the terminals open.  
Note: A 300-W model is shown above.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
26  
Read and Understand this Catalog  
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have  
any questions or comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year  
(or other period if specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,  
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER  
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET  
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS,  
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON  
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE  
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,  
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE  
MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of  
products in the customer's application or use of the products.  
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will  
be used.  
Know and observe all prohibitions of use applicable to this product.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON  
PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR  
SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction  
changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special  
model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with  
your OMRON representative at any time to confirm actual specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a  
warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application  
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.  
OMRON Corporation  
Tokyo, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69-2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
IL 60173-5302 U.S.A.  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2009 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
Printed in Japan  
1110  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
CSM_9_1_0211  
Cat. No. T041-E1-04  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  

相关型号:

S8JX-G03505CD

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON

S8JX-G03505D

Switch Mode Power Supply
OMRON

S8JX-G03512

Switch Mode Power Supply
OMRON

S8JX-G03512C

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON

S8JX-G03512CD

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON

S8JX-G03512D

Switch Mode Power Supply
OMRON

S8JX-G03515

Switch Mode Power Supply
OMRON

S8JX-G03515C

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON

S8JX-G03515CD

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON

S8JX-G03515D

Switch Mode Power Supply
OMRON

S8JX-G03524

Switch Mode Power Supply
OMRON

S8JX-G03524C

Wide Variety of Output Voltage Variations: 48 V for 15 to 150 W, and 5 or 12 V for 150 W
OMRON