S82Y-VK10F [OMRON]
Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement;型号: | S82Y-VK10F |
厂家: | OMRON ELECTRONICS LLC |
描述: | Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement |
文件: | 总12页 (文件大小:2363K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
New Product
Redundancy Unit
S8VK-R
Contribute to build high reliable systems
Compact and Cost-effective solution
for Back-up applications
Easy setup for system reliability
requirement
• Redundancy operating LED for the status confirmation
• A signal output for failure detection of power supplies
• By adjusting the power supply voltage to light up Balance LED,
the lifetime of power supplies will be more than twice. *1
• Wide range input
DC5-30V (S8VK-R10), DC10-60V (S8VK-R20)
• Wide operation temperature range: -40 to 70 °C
• Safety standards:
UL508/60950-1, CSA C22.2 No. 107.1/60950-1
EN50178, EN60950-1 Lloyd's standards *2
• EMS: EN61000-6-2
EMI: EN61000-6-3
• 5 year warranty *3
Refer to Safety Precautions for All Power Supplies and Safety
Precautions on page 9.
!
*1. The lifetime will depend on the connected power supply.
Refer to Functions on page 5.
*2. Scheduled to obtain certification in September, 2013.
*3. Five-year warranty conditions: Rated input voltage, 80% load, Ambient operating temperature: 40°C, Standard mounting.
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below.
S8VK-R@@
1
1. Output current
10: 10 A
20: 20 A
Ordering Information
Note: For details on normal stock models, contact your nearest OMRON representative.
Input voltage
DC5-30V
DC10-60V
Output current
Model number
S8VK-R10
S8VK-R20
10 A
20 A
1
S8VK-R
Specifications
Ratings, Characteristics, and Functions
I t e m
Output Current
10 A
20 A
Voltage
Current
5 to 30 VDC
2x 0 to 5 A
1x 0 to 10 A
10 A
10 to 60 VDC
2x 0 to 10 A
1x 0 to 20 A
20 A
Input
Continuous
Output
Current
Power Boost 12 A (Refer to Engineering Data)
24 A (Refer to Engineering Data)
0.56 V typ. 2x5 A
0.63 V typ. 1x10 A
0.7 V max. (-40°C 1x10 A)
0.67 V typ. 2x10 A
0.78 V typ. 1x20 A
0.9 V max. (-40°C 1x20 A)
Voltage
drop
Input to Output
6.5 W 2x5 A
7.1 W 1x10 A
0.8 W 0 A
15.8 W 2x10 A
18.0 W 1x20 A
0.8 W 0 A
Power
losses
Indicator
Contact
Indicator
Lighting: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ. (color: green)
Photo switch contact ON: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.
Contact Ratings: 30 VDC, 50 mA
REDUNDANCY
OK
Additional
functions
BALANCE
Lighting: Voltage difference between Vin1 and Vin2 is less than 50 mV typ. (color: green)
Ambient operating temperature -40 to 70°C (Refer to Engineering Data)
Storage temperature
-40 to 85°C
Ambient operating humidity
0% to 95% (Storage humidity: 0% to 95%)
Dielectric strength
1.0 kVAC for 1 min. (between all inputs outputs and
terminal)
(detection current: 20 mA)
0.5 kVAC for 1 min. (between all inputs outputs and Signal contact)
10 to 55 Hz, 0.375-mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35-mm single amplitude (5 G max.) for 80 min each in X, Y, and Z directions
150 m/s2, 3 times each in X, Y, and Z directions
Vibration resistance
Shock resistance
Conducted
Conforms to EN61204-3 EN55011 Class B and based on FCC Class B
Emission
Others
EMI
Radiated
Emission
Conforms to EN61204-3 EN55011 Class B
Conforms to EN61000-6-2
EMS
UL Listed: UL508 (Listing)
UL UR: UL60950-1 (Recognition)
cUL: CSA C22.2 No.107.1
cUR: CSA C22.2 No.60950-1
EN: EN50178, EN60950-1
Lloyd's standards *
Approved Standards
Degree of protection
Weight
IP20 by EN/IEC60529
183 g
462 g
* Scheduled to obtain certification in September, 2013.
2
S8VK-R
Connections
Block Diagrams
+V
+V
fuse:
R10 20A
R20 40A
IN 1
IN 2
+V
Only R20.
-V
OUTPUT
+V
fuse:
R10 20A
R20 40A
-V
-V
-V
Detection
circuit
REDUNDANCY
OK
Frame landing
Construction and Nomenclature
Nomenclature
10 A Models
20 A Models
S8VK-R10
S8VK-R20
1
2
3
2
1
3
5
6
5
6
7
7
4
4
No.
1
2
Name
Function
Input terminal 1
Input terminal 2
Connect the input 1 lines to these terminals.
Connect the input 2 lines to these terminals.
Connect the ground line to these terminals.
3
terminal
4
5
6
7
Output terminal
Status indicator (redundancy OK: Green)
Status indicator (voltage balance: Green)
Connect the load lines to these terminals.
Lighting: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.
Lighting: Voltage difference between Vin1 and Vin2 is less than 50 mV typ.
Status contact (redundancy OK: photo switch) Photo switch contact ON: Voltage difference between Vin1 and Vin2 is less than 2.4 V typ.
3
S8VK-R
Engineering Data
Derating Curve
Power Boost Function
This function is possible when used in combination with S8VK-G (All
Models).
120
A
B
C
Power Boost is a function that can output the temporary repeated
boost current larger than the rated current.
However, it should meet the following four Boost current conditions.
1. Time that the boost current flows: t1
100
80
2. The maximum value of the boost current: lp
3. The average output current: lave
4. The time ratio of the boost current flow: Duty
60
40
Note: Boost current conditions
20
0
• t1 ≤ 10 s
• Ip ≤ Rated boost current
• lave ≤ Rated current
−40 −25 −10
0
10 20 30 40 50 60 70 80
Ambient temperature (°C)
t1
t1 + t2
× 100 [%] ≤ 30%
Duty=
[A]
A: Standard mounting
B: Standard mounting, when contact mounted with S8VK-G
60°C and over: the derating is 2.5%/°C (when contact mounted
with S8VK-G)
Ip: Boost current
Rated current
C: Face-up mounting
50°C and over: the derating is 1.25%/°C
lave: Average current
Mounting
(B) Contact Mounting
(A) Standard (Vertical) mounting
t1
t2
• Do not allow the boost current to continue for more than 10
seconds.
Also, do not let the duty cycle exceed the boost current conditions.
These conditions may damage the Power supply.
• Ensure that the average current of one cycle of the boost current
does not exceed the rated output current.
This may damage the Power Supply.
• Lessen the load of the boost load current by adjusting the ambient
temperature and the mounting direction.
S8VK-R
POWER SUPPLY
(S8VK-G)
(C) Face-up mounting
Combinations with the S8VK-G
Redundant unit model
Redundancy Higher capasity
Power supply
model
S8VK-G015@@
S8VK-G030@@
S8VK-G060@@
S8VK-G12024
S8VK-G24024
S8VK-G24048
S8VK-G48024
S8VK-G48048
S8VK-R10
S8VK-R10
S8VK-R20
S8VK-R20
4
S8VK-R
Functions
Functions
Status
Output
Display
Green
Green
Relay switch output: OFF
(Normally ON)
Redundancy
Voltage Balance
---
Status Functions
Functions
Operation
Redundancy OK signal and LED will turn ON and light up when the input voltage difference is 2.4 V typ or less.
The signal and LED will detect the failure of a power supply on one side, or connecting errors of power supply
voltage.
Redundancy Status
(Refer to Chart 1.)
Balance LED will light up when the input voltage difference is 50 mV typ or less.
By adjusting the input voltage to light up LED, output current of each power supply will be balanced.
The lifetime as a power supply system will be more than twice comparing when there is only one power supply.
Applicable models: S8VK-G03005, S8VK-G06012, S8VK-G12024, S8VK-G240@@, S8VK-G480@@
By adjusting the input voltage to light up LED, the fluctuation of the output voltage will be less when one of the
power supply breaks.
Voltage Balance Status
(Refer to Chart 1.)
Chart 1: Operation Timing
Vin+2.4
Vin+1.2
Vin+0.05
Vin+0.05
Vin-0.05
Vin-2.4
Vin
Vin-0.05
Vin-1.2
Vin1 (UNIT: V)
Vin+2.4
Vin+1.2
Vin+0.05
Vin+0.05
Vin-0.05
Vin-1.2
Vin
Vin-0.05
Vin-2.4
Vin2 (UNIT: V)
LED: Lighting
Photo switch: ON
REDUNDANCY OK
LED: Lighting
BALANCE
Reference Value
Value
Reliability (MTBF)
Definition
S8VK-R10: 720,000 hrs.
S8VK-R20: 680,000 hrs.
MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device
failures, and indicates reliability of devices.
Therefore, it does not necessarily represent a life of the product.
Life expectancy
Definition
10 yrs. Min.
The life expectancy indicates average operating hours under the ambient temperature of 40°C and a load rate of 50%.
Normally this is determined by the life expectancy of the built-in aluminum electrolytic capacitor.
5
S8VK-R
Dimensions
S8VK-R10
(Unit: mm)
110
106
(1)
5
3.6 dia. (Bit #1)
34.9
75.4
90
8.5
5
5.7
3.5
4.7
7.62
(Sliding: 10 max.)
32
3.6 dia. (Bit #1)
Rail Stopper
S8VK-R20
117.8
112.2
5.0 dia. (Bit #2)
(1)
(4)
6.35
104.6
34.7
125
20.5
5
6.35
(10)
4.7
(Sliding: 7.5 max.)
8.2
40
5.0 dia. (Bit #2)
Rail Stopper
6
S8VK-R
DIN Rail (Order Separately)
Note: All units are in millimeters unless otherwise indicated.
Mounting Rail (Material: Aluminum)
PFP-100N
PFP-50N
0.15
7.3
4.5
0.3
0.15
27
35
15 25
10
25
25
25
15(5) *
1
10
1,000 (500) *
* Values in parentheses are for the PFP-50N.
Mounting Rail (Material: Aluminum)
PFP-100N2
16
4.5
0.3
35
27 24
29.2
1.5
15 25
10
25
25
25 15
1
10
1,000
End Plate
PFP-M
10
6.2
1.8
M4×8 pan-
head screw
1
35.5
35.5
50
1.8
11.5
1.3
4.8
10
M4 spring washer
Note: If there is a possibility that the Unit will be subject to vibration or shock, use a steel DIN Rail. Otherwise, metallic filings may result from
aluminum abrasion.
7
S8VK-R
Mounting Brackets
Name
Model
S82Y-VS10F
Front-mounting bracket (for S8VK-R10)
Front-mounting bracket (for S8VK-R20)
Side-mounting bracket (for S8VK-R10)
Side-mounting bracket (for S8VK-R20)
S82Y-VK10F
S82Y-VS10S
S82Y-VK10S
Type
Model
Dimensions
Appearance
41
4.5 dia. 0.1
Front-mounting
bracket
(for S8VK-R10)
S82Y-VS10F
35 0.1
7.3
10
40
50
t = 1.0
0.1
140
Front-mounting
bracket
(for S8VK-R20)
150
S82Y-VK10F
0.1
25
5.4
0.1
4.5 dia.
38
t = 2.0
Left-side mounting Right-side mounting
0.1
4.5 dia.
0.1
60
80
Side-mounting
bracket
(for S8VK-R10)
S82Y-VS10S
0.1
55
13
35
64
t = 2.0
73
0.1
0.1
15.5
40
49
50
Left-side mounting
Right-side mounting
0.1
4.5 dia.
Side-mounting
bracket
(for S8VK-R20)
0.1
140
125
S82Y-VK10S
150
t = 2.0
8
S8VK-R
Safety Precautions
Warning Indications
Precautions for Safe Use
Indicates a potentially hazardous
situation which, if not avoided, may
result in minor or moderate injury or in
property damage.
Wiring
CAUTION
• Minor fire may possibly occur. Ensure that input and output
terminals are wired correctly.
• Increases in the temperature of internal parts resulting from
heating of wiring materials may result in deterioration or damage to
parts. Use wiring materials suitable to the current being used. The
following wiring materials, torque and strip length are
recommended to prevent heating and possible fires in wiring
materials.
Supplementary comments on what to
do or avoid doing, to use the product
safely.
Precautions for
Safe Use
Supplementary comments on what to
do or avoid doing, to prevent failure to
operate, malfunction or undesirable
effect on product performance.
Precautions for
Correct Use
Recommend Wire Type
Terminal
Input
Model
AWG
Solid wire
Twisted wire
2.5 mm2
4 mm2
Meaning of Product Safety Symbols
S8VK-R10
S8VK-R20
S8VK-R10
S8VK-R20
AWG14 to 12 2.5 to 4 mm2
AWG12 to 10 4 to 6 mm2
AWG14 to 12 2.5 to 4 mm2
AWG12 to 10 4 to 6 mm2
2.5 mm2
4 mm2
Used to warn of the risk of minor injury caused by
high temperatures.
Output
Status
contact
S8VK-R@@ AWG16
1.5 mm2
---
All
terminals
Used for general mandatory action precautions
for which there is no specified symbol.
wires to be stripped: 8 mm
• On rare occasions there is a risk of internal element deterioration
and damage if use is continued in a short-circuit or over-current
state.
• Do not apply more than 75N force to the terminal block when
tightening it.
Use to indicate prohibition when there is a risk of
minor injury from electrical shock or other source
if the product is disassembled.
• Use within a range that does not exceed the output current rating.
When a load short-circuit occurs, the short-circuit current of two
power supply units flows. Use output wiring that can handle the
short-circuit current of two units. If the wiring does not have
sufficient current capacity, connect a fuse on the output side.
Recommended fuse S8VK-R10: 15 A, S8VK-R20: 30 A Fast-
acting type
!CAUTION
Risk of a mild burn on rare occasions. Do not touch
the device unit while it is powered on or immediately
after the power is turned off.
If the current rating of the output terminal is exceeded on the S8VK-
R20, always use multiple terminals simultaneously.
• Risk of damage to internal components. Do not use in a state that
exceeds the rated current of the signal output.
The ignition may accidentally be caused. Tighten
terminal screws to a specified torque 4.43 to
5.31 lb-in (0.5 to 0.6 N·m).
Minor electric shock, fire, or Product failure may
occasionally occur. Do not allow any pieces of metal
or conductors or any clippings or cuttings resulting
from installation work to enter the Product.
Installation Environment
• Do not use the Redundancy Unit in locations subject to shocks or
vibrations. In particular, install the Redundancy Unit as far away as
possible from contactors or other devices that are a vibration
source.
Risk of product damage. Do not reverse the polarity
of the device input terminals when wiring.
• Install the Redundancy Unit well away from any sources of strong,
high-frequency noise and surge.
Ambient Operating and Storage Environments
• Store the product with ambient temperature −40 to 85°C, and
relative humidity 0 to 95%.
Risk of internal component deterioration and
damage. Do not connect an AC power supply.
• The internal parts may occasionally be deteriorated or broken. Do
not use at a temperature that exceed the operating temperature
range for the mounting type.
• Use the product where the relative humidity is 0 to 95%.
• Avoid places where the product is subjected to direct sunlight.
• Avoid places where the product is subjected to penetration of
liquid, foreign substance, or corrosive gas.
Minor electric shock, fire, or Product failure may
occasionally occur. Do not disassemble, modify, or
repair the Product or touch the interior of the
Product.
• Avoid places subject to shock or vibration.A device such as a
contact breaker may be a vibration source.
Set the Redundancy Unit as far as possible from possible sources
of shock or vibration.
• If the Redundancy Unit is used in an area with excessive electronic
noise or surge, be sure to separate the Redundancy Unit as far as
possible from the noise sources.
9
S8VK-R
Precautions for Correct Use
Mounting
Dielectric Strength Test
The long-term reliability of the S8VK-R can be increased by installing
it properly and sufficiently considering heat dissipation.
Install the S8VK-R so that the air flow circulates around it, because
the S8VK-R is designed to radiate heat by means of natural air
circulation.
The S8VK-R is designed to withstand a voltage test of 1 kV AC
between all input/output terminals and the chassis, and 0.5 kV AC
between all input/output terminals and the signal output terminal, for
one minute.
Note:
Can be used in a contact mounting with the S8VK-G (not covered by
safety certification). Two S8VK-G units cannot be mounted together
in a contact mounting.
1. The S8VK-R may possibly be damaged from the impulse voltage
if a testing device switch is used to abruptly apply or shut off 1 kV
AC, 0.5 kV AC. Increase the applied voltage gradually using the
voltage adjustment on the testing device.
2. When testing, always short-circuit all terminals to prevent damage
*4
*4
*1
*2
to the output terminal.
Signal output
Photo switch output
Photo switch ON when input voltage difference is 2.4 V typ. or less.
30 VDC max. (LVLC), 50 mA max., residual voltage when ON: 2 V
max., leakage current when OFF: 0.1 mA max.
*1. Convection of air
*2. 75 mm min.
*3. 75 mm min.
*4. 20 mm min.
Status display LEDs
The status display LEDs show the status of the input power as shown
in the table below.
*3
*1
Redundancy OK
Green on: Input voltage difference is 2.4 V typ. or less.
Voltage balance
Input Voltage
Rating
Green on: Input voltage difference is 50 mV typ. or less.
The redundancy OK display/signal operates when the voltage
difference is no more than 2.4 V typ. When using a 5 V or 12 V power
supply, verify that there is no difference in the output voltages of the
power supplies.
The voltage balance display does not guarantee current balance. The
degree of balance varies by model, and therefore if you require
operation with balanced current, check the output current of each
power supply unit.
S8VK-R10: DC5 to 30V
S8VK-R20: DC10 to 60V
Input Power Supply Selection
This product contains an internal fuse. If a power supply other than
the S8VK-G is used, the fuse may blow, depending on the state of the
load. Do not connect a power supply other than the S8VK-G to this
product.
The models below use a voltage balance display, and cannot be used
as a current balance.
S8VK-G015@@
If you are building a redundant system, never use in a state that
exceeds the rated current of the power supply. If one of the power
supplies goes down, there is a risk that the voltage on the load side
cannot be attained.
Use the same model for the power supplies that are connected.
On rare occasions internal element deterioration and damage may
occur if use is continued in a short-circuit or over-current state. Do not
continue use for more than 10 seconds.
S8VK-G03012·S8VK-G03024
S8VK-G06024
When adjusting the voltage based on the voltage balance, adjust the
voltage of only one power supply. If you must adjust the voltages of
both power supplies, be sure to check the output voltage before use.
If you want to use the voltage balance display to ensure that the
expected life is obtained, use the same thickness and length of wiring
from each S8VK-G to the S8VK-R.
Do not use in applications where load rush current or overload may
frequently occur. Slight risk of deterioration and damage due to
internal loss.
The signal output / status LED may occasionally not operate stably.
When using in environments where the temperature is less than
−25 °C, always adjust the 5 V power supply to 5.3 V or higher.
Connections
It is possible to connect S8VK-R like below.
REDUNDANCY
MONITOR
IN1 IN2
FG
OPTIONAL
REDUNDANCY
UNIT
POWER SUPPLY
POWER SUPPLY
OUT
L
N
L N
LOAD
L
N
10
Terms and Conditions of Sale
1. Offer; Acceptance. These terms and conditions (these "Terms") are deemed
part of all quotes, agreements, purchase orders, acknowledgments, price lists,
catalogs, manuals, brochures and other documents, whether electronic or in
writing, relating to the sale of products or services (collectively, the "Products")
by Omron Electronics LLC and its subsidiary companies (“Omron”). Omron
objects to any terms or conditions proposed in Buyer’s purchase order or other
documents which are inconsistent with, or in addition to, these Terms.
2. Prices; Payment Terms. All prices stated are current, subject to change with-
out notice by Omron. Omron reserves the right to increase or decrease prices
on any unshipped portions of outstanding orders. Payments for Products are
due net 30 days unless otherwise stated in the invoice.
ITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS.
BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR
INTENDED USE. Omron further disclaims all warranties and responsibility of
any type for claims or expenses based on infringement by the Products or oth-
erwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obli-
gation hereunder shall be, at Omron’s election, to (i) replace (in the form
originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying
Product, or (iii) repay or credit Buyer an amount equal to the purchase price of
the non-complying Product; provided that in no event shall Omron be responsi-
ble for warranty, repair, indemnity or any other claims or expenses regarding
the Products unless Omron’s analysis confirms that the Products were prop-
erly handled, stored, installed and maintained and not subject to contamina-
tion, abuse, misuse or inappropriate modification. Return of any Products by
Buyer must be approved in writing by Omron before shipment. Omron Compa-
nies shall not be liable for the suitability or unsuitability or the results from the
use of Products in combination with any electrical or electronic components,
circuits, system assemblies or any other materials or substances or environ-
ments. Any advice, recommendations or information given orally or in writing,
are not to be construed as an amendment or addition to the above warranty.
See http://www.omron247.com or contact your Omron representative for pub-
lished information.
3. Discounts. Cash discounts, if any, will apply only on the net amount of invoices
sent to Buyer after deducting transportation charges, taxes and duties, and will
be allowed only if (i) the invoice is paid according to Omron’s payment terms
and (ii) Buyer has no past due amounts.
4. Interest. Omron, at its option, may charge Buyer 1-1/2% interest per month or
the maximum legal rate, whichever is less, on any balance not paid within the
stated terms.
5. Orders. Omron will accept no order less than $200 net billing.
6. Governmental Approvals. Buyer shall be responsible for, and shall bear all
costs involved in, obtaining any government approvals required for the impor-
tation or sale of the Products.
7. Taxes. All taxes, duties and other governmental charges (other than general
real property and income taxes), including any interest or penalties thereon, 14. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE
imposed directly or indirectly on Omron or required to be collected directly or
indirectly by Omron for the manufacture, production, sale, delivery, importa-
tion, consumption or use of the Products sold hereunder (including customs
duties and sales, excise, use, turnover and license taxes) shall be charged to
and remitted by Buyer to Omron.
FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY
WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS
BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual
price of the Product on which liability is asserted.
8. Financial. If the financial position of Buyer at any time becomes unsatisfactory
to Omron, Omron reserves the right to stop shipments or require satisfactory 15. Indemnities. Buyer shall indemnify and hold harmless Omron Companies and
security or payment in advance. If Buyer fails to make payment or otherwise
comply with these Terms or any related agreement, Omron may (without liabil-
ity and in addition to other remedies) cancel any unshipped portion of Prod-
ucts sold hereunder and stop any Products in transit until Buyer pays all
amounts, including amounts payable hereunder, whether or not then due,
which are owing to it by Buyer. Buyer shall in any event remain liable for all
unpaid accounts.
their employees from and against all liabilities, losses, claims, costs and
expenses (including attorney's fees and expenses) related to any claim, inves-
tigation, litigation or proceeding (whether or not Omron is a party) which arises
or is alleged to arise from Buyer's acts or omissions under these Terms or in
any way with respect to the Products. Without limiting the foregoing, Buyer (at
its own expense) shall indemnify and hold harmless Omron and defend or set-
tle any action brought against such Companies to the extent based on a claim
that any Product made to Buyer specifications infringed intellectual property
rights of another party.
9. Cancellation; Etc. Orders are not subject to rescheduling or cancellation
unless Buyer indemnifies Omron against all related costs or expenses.
10. Force Majeure. Omron shall not be liable for any delay or failure in delivery 16. Property; Confidentiality. Any intellectual property in the Products is the exclu-
resulting from causes beyond its control, including earthquakes, fires, floods,
strikes or other labor disputes, shortage of labor or materials, accidents to
machinery, acts of sabotage, riots, delay in or lack of transportation or the
requirements of any government authority.
sive property of Omron Companies and Buyer shall not attempt to duplicate it
in any way without the written permission of Omron. Notwithstanding any
charges to Buyer for engineering or tooling, all engineering and tooling shall
remain the exclusive property of Omron. All information and materials supplied
by Omron to Buyer relating to the Products are confidential and proprietary,
and Buyer shall limit distribution thereof to its trusted employees and strictly
prevent disclosure to any third party.
11. Shipping; Delivery. Unless otherwise expressly agreed in writing by Omron:
a.Shipments shall be by a carrier selected by Omron; Omron will not drop ship
except in “break down” situations.
b. Such carrier shall act as the agent of Buyer and delivery to such carrier shall 17. Export Controls. Buyer shall comply with all applicable laws, regulations and
constitute delivery to Buyer;
licenses regarding (i) export of products or information; (iii) sale of products to
“forbidden” or other proscribed persons; and (ii) disclosure to non-citizens of
regulated technology or information.
c. All sales and shipments of Products shall be FOB shipping point (unless oth-
erwise stated in writing by Omron), at which point title and risk of loss shall
pass from Omron to Buyer; provided that Omron shall retain a security inter- 18. Miscellaneous. (a) Waiver. No failure or delay by Omron in exercising any right
est in the Products until the full purchase price is paid;
d.Delivery and shipping dates are estimates only; and
e.Omron will package Products as it deems proper for protection against nor-
mal handling and extra charges apply to special conditions.
and no course of dealing between Buyer and Omron shall operate as a waiver
of rights by Omron. (b) Assignment. Buyer may not assign its rights hereunder
without Omron's written consent. (c) Law. These Terms are governed by the
law of the jurisdiction of the home office of the Omron company from which
Buyer is purchasing the Products (without regard to conflict of law princi-
ples). (d) Amendment. These Terms constitute the entire agreement between
Buyer and Omron relating to the Products, and no provision may be changed
or waived unless in writing signed by the parties. (e) Severability. If any provi-
sion hereof is rendered ineffective or invalid, such provision shall not invalidate
any other provision. (f) Setoff. Buyer shall have no right to set off any amounts
against the amount owing in respect of this invoice. (g) Definitions. As used
herein, “including” means “including without limitation”; and “Omron Compa-
nies” (or similar words) mean Omron Corporation and any direct or indirect
subsidiary or affiliate thereof.
12. Claims. Any claim by Buyer against Omron for shortage or damage to the
Products occurring before delivery to the carrier must be presented in writing
to Omron within 30 days of receipt of shipment and include the original trans-
portation bill signed by the carrier noting that the carrier received the Products
from Omron in the condition claimed.
13. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the
Products will be free from defects in materials and workmanship for a period of
twelve months from the date of sale by Omron (or such other period expressed
in writing by Omron). Omron disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABIL-
Certain Precautions on Specifications and Use
1. Suitability of Use. Omron Companies shall not be responsible for conformity
with any standards, codes or regulations which apply to the combination of the
Product in the Buyer’s application or use of the Product. At Buyer’s request,
ADDRESS THE RISKS, AND THAT THE OMRON’S PRODUCT IS PROP-
ERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Omron will provide applicable third party certification documents identifying 2. Programmable Products. Omron Companies shall not be responsible for the
ratings and limitations of use which apply to the Product. This information by
itself is not sufficient for a complete determination of the suitability of the Prod- 3. Performance Data. Data presented in Omron Company websites, catalogs
user’s programming of a programmable Product, or any consequence thereof.
uct in combination with the end product, machine, system, or other application
or use. Buyer shall be solely responsible for determining appropriateness of
the particular Product with respect to Buyer’s application, product or system.
Buyer shall take application responsibility in all cases but the following is a
non-exhaustive list of applications for which particular attention must be given:
and other materials is provided as a guide for the user in determining suitabil-
ity and does not constitute a warranty. It may represent the result of Omron’s
test conditions, and the user must correlate it to actual application require-
ments. Actual performance is subject to the Omron’s Warranty and Limitations
of Liability.
(i) Outdoor use, uses involving potential chemical contamination or electrical 4. Change in Specifications. Product specifications and accessories may be
interference, or conditions or uses not described in this document.
(ii) Use in consumer products or any use in significant quantities.
(iii) Energy control systems, combustion systems, railroad systems, aviation
systems, medical equipment, amusement machines, vehicles, safety equip-
ment, and installations subject to separate industry or government regulations.
(iv) Systems, machines and equipment that could present a risk to life or prop-
erty. Please know and observe all prohibitions of use applicable to this Prod-
uct.
changed at any time based on improvements and other reasons. It is our prac-
tice to change part numbers when published ratings or features are changed,
or when significant construction changes are made. However, some specifica-
tions of the Product may be changed without any notice. When in doubt, spe-
cial part numbers may be assigned to fix or establish key specifications for
your application. Please consult with your Omron’s representative at any time
to confirm actual specifications of purchased Product.
5. Errors and Omissions. Information presented by Omron Companies has been
checked and is believed to be accurate; however, no responsibility is assumed
for clerical, typographical or proofreading errors or omissions.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS
RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO
OMRON INDUSTRIAL AUTOMATION • THE AMERICAS HEADQUARTERS
Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELECTRONICS DE MEXICO • HEAD OFFICE
México DF • 52.55.59.01.43.00 • 001.800.556.6766 • mela@omron.com
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS DE MEXICO • SALES OFFICE
Apodaca, N.L. • 52.81.11.56.99.20 • 001.800.556.6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON EUROpE B.V. • Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands.
Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu
• Tel: +31 (0) 23 568 13 00
•
Cat. No. T059-E3-01 06/13
Note: Specifications are subject to change.
© 2013 Omron Electronics LLC
Printed in U.S.A.
相关型号:
S82Y-VK10S
Contribute to build high reliable systems Compact and Cost-effective solution for Back-up applications Easy setup for system reliability requirement
OMRON
©2020 ICPDF网 联系我们和版权申明