MKS3P6VAC [OMRON]

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT;
MKS3P6VAC
型号: MKS3P6VAC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总9页 (文件大小:2231K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General-purpose Relays  
MK-S (New Models)  
CSM_MK-S_DS_E_6_1  
New Super MK Relays.  
Models with Latching Lever Added to  
the Series.  
• Same mounting and internal wiring as the previous Super  
MK Relays  
• Built-in mechanical indicator enables checking contact  
operation.  
• Two modes can be used to check circuits for models with  
latching lever.  
• Nameplate provided on models with latching lever.  
• All materials are RoHS compliant.  
• UL and IEC (TÜV) certification.  
Features  
Models with Latching Lever  
Operating Method for Latching Lever  
Operation indicator *  
Nameplate  
Relay in  
Normal Operation  
For Momentary  
Operation  
For Lock  
Operation  
Mechanical indicator  
Latching lever  
DC: Blue  
AC: Red  
Yellow  
button  
* The operation indicator is built in only on specified models.  
Example of Applications of Models with Latching  
Slide the latching lever  
to the first position,  
then press the yellow  
button with an  
Slide the latching  
lever to the second  
position.  
(The contact is now in  
the locked position.)  
Levers  
Operation checks in relay sequence circuits  
insulated tool to  
operate the contact.  
Model Number Structure  
Model Number Legend  
MKS@@@@@-@-@  
1 2 3 4 5  
6
7
1. Contact Form  
2: DPDT  
5. Coil Polarity  
Blank: Standard  
3: 3PDT  
1:  
Reverse polarity (DC coil only)  
2. Terminals  
6. Surge Absorption  
P: Plug-in  
Blank: Standard  
D:  
V:  
Surge absorber diode (DC coil only)  
Surge absorber varistor (AC coil only)  
3. Mechanical Indicator/Test Button  
Blank: Mechanical indicator  
7. Internal Connections  
I:  
Mechanical indicator and lockable test button  
Blank: Standard  
2 or 5: Non-standard connections (Refer to “Terminal  
Arrangement and Internal Connection (Bottom View)”.)  
4. LED Indicator  
Blank: Standard  
N:  
LED indicator  
8. Rated Voltage  
(Refer to “Coil Ratings”.)  
1
MK-S  
Ordering Information  
List of Models  
Contact  
form  
Internal connections  
(See note 3.)  
With mechanical indicator  
and lockable test button  
Type  
Terminals  
With mechanical indicator  
Coil ratings  
Standard  
MKS2P  
MKS2PI  
DPDT  
Non-standard  
Standard  
MKS2P-2  
MKS2PI-2  
Standard  
Models  
MKS3P  
MKS3PI  
AC/DC  
3PDT  
DPDT  
3PDT  
DPDT  
3PDT  
DPDT  
3PDT  
DPDT  
3PDT  
DPDT  
3PDT  
MKS3P-2  
MKS3PI-2  
Non-Standard  
MKS3P-5  
MKS3PI-5  
Standard  
MKS2PN(1)  
MKS2PN(1)-2  
MKS3PN(1)  
MKS3PN(1)-2  
MKS3PN(1)-5  
MKS2P(1)-D  
MKS2P(1)-D-2  
MKS3P(1)-D  
MKS3P(1)-D-2  
MKS3P(1)-D-5  
MKS2PN-D  
MKS2PN-D-2  
MKS3PN-D  
MKS3PN-D-2  
MKS3PN-D-5  
MKS2P-V  
MKS2PIN(1)  
MKS2PIN(1)-2  
MKS3PIN(1)  
MKS3PIN(1)-2  
MKS3PIN(1)-5  
MKS2PI(1)-D  
MKS2PI(1)-D-2  
MKS3PI(1)-D  
MKS3PI(1)-D-2  
MKS3PI(1)-D-5  
MKS2PIN-D  
MKS2PIN-D-2  
MKS3PIN-D  
MKS3PIN-D-2  
MKS3PIN-D-5  
MKS2PI-V  
Non-standard  
Standard  
Models with  
LED Indicator  
(See note 2.)  
AC/DC  
Non-Standard  
Standard  
Non-standard  
Standard  
Models with  
Diode  
(See note 2.)  
DC  
Non-Standard  
Plug-in  
Standard  
Non-standard  
Standard  
Models with  
LED Indicator  
and Diode  
DC  
Non-Standard  
Standard  
Non-standard  
Standard  
MKS2P-V-2  
MKS3P-V  
MKS2PI-V-2  
MKS3PI-V  
Models with  
Varistor  
AC  
MKS3P-V-2  
MKS3P-V-5  
MKS2PN-V  
MKS2PN-V-2  
MKS3PN-V  
MKS3PN-V-2  
MKS3PN-V-5  
MKS3PI-V-2  
MKS3PI-V-5  
MKS2PIN-V  
MKS2PIN-V-2  
MKS3PIN-V  
MKS3PIN-V-2  
MKS3PIN-V-5  
Non-Standard  
Standard  
Non-standard  
Standard  
Models with  
LED Indicator  
and Varistor  
AC  
Non-Standard  
Note: 1. When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.  
Example: MKS3P 24 VDC  
Rated voltage  
2. The DC coil comes in two types: standard coil polarity and reverse coil polarity.  
Refer to Terminal Arrangement and Internal Connections (Bottom View).  
Example: MKS2PIN1-2 24 VDC  
Reverse coil polarity  
3. Refer to Terminal Arrangement and Internal Connections (Bottom View) for non-standard internal connections.  
List of Models (Order Separately)  
Item  
Type  
Model  
8-pin  
PF083A-E  
11-pin  
8-pin  
PF113A-E  
PF083A-D  
PF113A-D  
Track-mounted  
Socket  
11-pin  
Hold-down Clip  
(For PF083A-E and PF113A-E)  
PFC-A1  
2
MK-S  
Specifications  
Ratings  
Coil Ratings  
Rated current  
50 Hz 60 Hz  
Must operate  
voltage  
Must release  
voltage  
Power  
consumption  
Rated voltage  
Coil resistance  
Max. voltage  
6 V  
443 mA  
221 mA  
110 mA  
26.6 mA  
24.2 mA  
13.3 mA  
12.1 mA  
10.0 mA  
11.0 mA  
224 mA  
112 mA  
55.8 mA  
28.1 mA  
13.5 mA  
12.3 mA  
10.8 mA  
385 mA  
193 mA  
96.3 mA  
23.1 mA  
21.0 mA  
11.6 mA  
10.5 mA  
11.5 mA  
9.6 mA  
3.1 Ω  
12 V  
13.7 Ω  
48.4 Ω  
760 Ω  
24 V  
30% min. of rated  
voltage at 60 Hz  
25% min. of rated  
voltage at 50 Hz  
Approx. 2.3 VA  
at 60 Hz  
Approx. 2.7 VA  
at 50 Hz  
100 V  
110 V  
200 V  
220 V  
230 V  
240 V  
6 V  
AC  
932 Ω  
3,160 Ω  
3,550 Ω  
4,250 Ω  
4,480 Ω  
26.7 Ω  
107 Ω  
80% max. of  
rated voltage  
110% of rated  
voltage  
12 V  
24 V  
430 Ω  
15% min. of rated  
voltage  
DC  
48 V  
1,710 Ω  
7,390 Ω  
8,960 Ω  
11,576 Ω  
Approx. 1.4 W  
100 V  
110 V  
125 V  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/20% for AC rated current and  
15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C.  
3. The maximum voltage is one that is applicable instantaneously to the Relay coil at 23°C and not continuously.  
4. For DC-operated Relays with the LED indicator built-in, add an LED current of approx. 5 mA to the rated current.  
Contact Ratings  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4)  
Load  
Contact mechanism  
Contact material  
Single  
AgSnIn  
10 A, 250 VAC  
10A, 30 VDC  
NO  
NC  
Rated load  
7 A, 250 VAC  
5 A, 250 VAC  
5 A, 30 VDC  
Rated carry current  
10 A  
Max. switching voltage  
Max. switching current  
250 VAC, 250 VDC  
10 A  
NO 2,500 VA/300 W  
NC 1,250 VA/150 W  
Max. switching power  
3
MK-S  
Characteristics  
Contact resistance  
Operate time  
100 mΩ max.  
AC: 20 ms max.  
DC: 30 ms max.  
Release time  
20 ms max. (40 ms max. for built-in Diode Relays)  
Mechanical: 18,000 operations/h  
Max. operating frequency  
Insulation resistance  
Electrical: 1,800 operations/h (under rated load)  
100 MΩ min. (at 500 VDC)  
2,500 VAC 50/60 Hz for 1 min between coil and contacts  
1,000 VAC 50/60 Hz for 1 min between contacts of same polarity and terminals of the same polarity  
2,500 VAC 50/60 Hz for 1 min between current-carrying parts, non-current-carrying parts, and opposite polarity  
Dielectric strength  
Insulation method  
Basic insulation  
4.5 kV between coil and contacts (with 1.2 × 50 μs impulse wave)  
3.0 kV between contacts of different polarity (with 1.2 × 50 μs impulse wave)  
Impulse withstand voltage  
Pollution degree  
3
Rated insulation voltage  
250 V  
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)  
Vibration resistance  
Shock resistance  
Endurance  
Destruction: 1,000 m/s2 (approx. 100 G)  
Malfunction: 100 m/s2 (approx. 10 G)  
Mechanical: 5,000,000 operations min. (at 18,000 operations/h under rated load)  
Electrical: 100,000 operations h. (at 1,800 operations/h under rated load)  
Failure rate P level (reference value) 10 mA at 1 VDC  
Ambient temperature  
Ambient humidity  
Weight  
Operating: –40 to 60°C (with no icing or condensation)  
Operating: 5% to 85%  
Approx. 90 g  
Note: 1. The values given above are initial values.  
2. P level: λ60 = 0.1 × 10-6/operation  
3. Ambient temperature of models with LED indicator is 25 to 60°C.  
Approved Standards  
UL508 (File No. E41515)  
IEC Standard/TÜV Certification: IEC61810-1  
(Certification No. R50104853)  
Coil ratings  
Contact ratings  
Operations  
10 A, 250 V AC 50/60 Hz (Resistive)  
10 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
Coil ratings  
Contact ratings  
Operations  
N.O.  
contact  
100,000  
10 A, 250 V AC 50/60 Hz (Resistive)  
10 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
5 A, 250 V AC 50/60 Hz (Resistive)  
5 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
N.O.  
contact  
6, 12, 24, 48,  
100, 110 VDC  
6, 12, 24, 100,  
110,200,220,  
240 VAC  
6 to110 VDC  
6 to 240 VAC  
100,000  
10 A, 250 V AC 50/60 Hz (Resistive)  
10 A, 30 V DC (Resistive)  
7 A, 250 V AC 50/60 Hz (General Use)  
N.C.  
contact  
100,000  
N.C.  
contact  
100,000  
CSA Standard: CSA C22.2 No. 14 (File No. LR35535)  
Note: When Relays are mounted on the PF083A-E or PF113A-E, the  
Number of  
Poles  
maximum carrying current is 9 A.  
Coil ratings  
Contact ratings  
Operations  
10 A, 250 V AC (Resistive)  
10 A, 30 V DC (Resistive)  
7 A, 250 V AC (General Use)  
10 A, 250 V AC (Resistive)  
Same Polarity  
2
3
100,000  
6 to125 VDC  
6 to 240 VAC  
10 A, 30 V DC (Resistive)  
Same Polarity  
100,000  
7 A, 250 V AC (General Use)  
Same Polarity  
Engineering Data  
Reference Data  
Maximum Switching Power  
Rated Carry Current vs. Ambient Rated Temperature  
100  
10  
50  
30  
UL derating curve  
DC resistive load  
with NO contact  
AC resistive load  
with NO contact  
10  
5
0
AC inductive  
load  
(cosφ = 0.4)  
5
3
AC resistive load  
with NC contact  
DC resistive  
load with  
NC contact  
1
40  
20  
0
20  
40  
60  
80  
10  
30  
50  
100  
300 500 1.000  
Ambient temperature (°C)  
Switching voltage (V)  
Note: The lower limit of the ambient operating temperature for models with built-in operation indicators is 25°C.  
4
MK-S  
Dimensions  
(Unit: mm)  
Models without Latching Lever  
Models with Latching Lever  
34.5 max.  
34.5 max.  
34.5 max.  
0.8  
52.5 max.  
34.5 max.  
0.8  
52.5 max.  
Sockets  
See below for Socket dimensions.  
Surface-mounting Socket (for track or screw mounting)  
Socket  
Finger-protection models  
---  
Maximum carry  
current  
10 A  
5 A  
PF083A-E  
PF083A-D  
PF083A  
2 poles  
3 poles  
PF113A-E  
PF113A-E-D  
PF113A  
Note: Use the Surface-mounting Sockets (i.e., finger-protection models) with “-E” at the end of the model number. When using the PF083A and  
PF113A, be sure not to exceed the Socket's maximum carry current of 5 A. Using at a current exceeding 5 A may lead to burning. Round  
terminals cannot be used for finger-protection models. Use Y-shaped terminals.  
PF083A-E (Conforming to EN 50022)  
PF113A-E (Conforming to EN 50022)  
Terminal Arrangement  
Terminal Arrangement  
Eight, M3.5 × 7 sems  
Eleven, M3.5 × 7 sems  
7
4
7
4
52 max.  
35.4  
52 max.  
35.4  
2
3.5  
33  
41 max.  
Mounting Holes  
Mounting Holes  
21 max.  
3.5  
2
4
34  
42.8 max.  
Two, M4 or two 4.5-dia. holes  
Two, M4 or two 4.5-dia. holes  
31 max.  
33 0.2  
33 0.2  
5
MK-S  
PF083A-D  
PF113A-D  
8
Terminal Arrangement  
8
Terminal Arrangement  
24  
6
22  
5
12  
4
14  
3
5.5  
21  
32 24  
22 12  
5 4  
5.5  
6
8
7
27  
4
27  
4
Eight, M4 screws  
Eight, M4 screws  
7
8
1
2
9
10  
3
14  
2
A1  
A2  
21  
11  
A1  
11  
31  
1
11  
34 A2  
65  
Mounting Holes  
65  
Mounting Holes  
Two, M4 or two 4.5-dia. hole  
Two, M4 or two 4.5-dia. hole  
30  
30  
38  
38  
Hold-down Clips  
PFC-A1  
(2 pieces per set)  
4.6  
60.8  
62  
6
4.5  
Mounting Tracks  
PFP-100N, PFP-50N  
PFP-100N2  
(Conforming to EN 50022)  
(Conforming to EN 50022)  
16  
7.3 0.15  
35 0.3  
4.5  
4.5  
27  
35 0.3  
29.2  
1.5  
24  
27 0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
*
1
10  
10  
10  
10  
1000 4  
1000 (500)*  
* This dimension applies to the PFP-50N Mounting Track.  
*
A total of twelve 25 × 4.5 elliptic holes is provided with six  
holes cut from each track end at a pitch of 10 mm.  
Mounting Height with Sockets  
Surface-mounting Sockets  
Three  
poles  
Two  
poles  
87.8  
(See  
note.)  
77.8  
(See  
note.)  
84.3  
74.3  
PF083A(-E)  
PF113A(-E)  
Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting.  
6
MK-S  
Terminal Arrangement and Internal Connection (Bottom View)  
MKS2P(I)  
MKS2P(I)-2  
MKS3P(I)  
MKS3P(I)-2  
MKS3P(I)-5  
Standard Models  
(AC/DC Coil)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
8
4
3
9
9
3
9
3
2
10  
1
8
1
8
10  
2
10  
2
1
11  
11  
1
11  
1
MKS2P(I)N  
MKS2P(I)N-2  
MKS3P(I)N  
MKS3P(I)N-2  
MKS3P(I)N-5  
Models with  
LED Indicator  
(AC Coil)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
4
8
3
9
3
9
3
9
2
10  
1
8
1
8
2
10  
2
10  
1
11  
1
11  
1
11  
MKS2P(I)N  
MKS2P(I)N-2  
MKS3P(I)N  
MKS3P(I)N-2  
MKS3P(I)N-5  
Models with Diode  
(DC Coil:  
Standard Polarity)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
4
8
3
9
3
9
3
9
2
10  
1
8
1
8
2
10  
2
10  
1
11  
1
11  
1
11  
MKS2P(I)N1  
MKS2P(I)N1-2  
MKS3P(I)N1  
MKS3P(I)N1-2  
MKS3P(I)N1-5  
Models with  
LED Indicator and Diode  
(DC Coil:  
Reverse Polarity)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
8
4
3
9
3
9
3
9
2
10  
2
10  
1
8
1
8
2
10  
1
11  
1
11  
1
11  
MKS2P(I)-D  
MKS2P(I)-D-2  
MKS3P(I)-D  
MKS3P(I)-D-2  
MKS3P(I)-D-5  
Standard Models  
(DC Coil:  
Standard Polarity)  
5
5
4
4
6
6
6
5
7
7
5
5
7
3
2
3
2
6
7
6
7
4
8
4
8
4
8
3
9
3
9
3
9
2
10  
1
8
1
8
2
10  
2
10  
11  
1
1
11  
1
11  
MKS2P(I)1-D  
MKS2P(I)1-D-2  
MKS3P(I)1-D  
MKS3P(I)1-D-2  
MKS3P(I)1-D-5  
Models with Diode  
(DC Coil:  
Reverse Polarity)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
4
8
3
9
3
9
3
9
2
10  
2
10  
1
8
1
8
2
10  
1
11  
1
11  
1
11  
MKS2P(I)N-D  
MKS2P(I)N-D-2  
MKS3P(I)N-D  
MKS3P(I)N-D-2  
MKS3P(I)N-D-5  
Models with  
LED indicator  
(DC Coil)  
5
5
4
4
6
6
6
7
5
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
8
4
3
9
3
9
3
9
2
10  
1
8
1
8
2
10  
2
10  
1
11  
1
11  
11  
1
7
MK-S  
MKS2P(I)-V  
MKS2P(I)-V-2  
MKS3P(I)-V  
MKS3P(I)-V-2  
MKS3P(I)-V-5  
Models with Varistor  
(AC Coil)  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
4
8
4
8
3
9
3
9
3
9
2
10  
2
10  
1
8
1
8
2
10  
1
11  
1
11  
11  
1
MKS2P(I)N-V  
MKS2P(I)N-V-2  
MKS3P(I)N-V  
MKS3P(I)N-V-2  
MKS3P(I)N-V-5  
Models with  
LED indicator and  
Varistor  
5
5
4
4
6
6
6
5
7
5
7
5
7
3
2
3
2
6
7
6
7
4
8
(AC Coil)  
8
4
4
8
3
9
3
9
3
9
2
10  
1
8
1
8
2
10  
2
10  
1
11  
1
11  
1
11  
Safety Precautions  
Refer to Safety Precautions for All Relays.  
Safety Precautions for Correct Use  
Installation  
Mount the MK-S with the marking at the bottom.  
Handling  
Check the coil polarity of models with built-in operation indicator (DC operation coil) and wire them correctly .  
Test Button  
Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON.  
Before using the test button, confirm that circuits, the load, and any other connected item will operate safely.  
Check that the test button is released before turning ON relay circuits.  
If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position.  
Use an insulated tool when you operate the test button.  
Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the  
Relay is in a complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only  
the requirements for basic insulation are fulfilled.  
8
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2011.5  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2011 All Right Reserved.  

相关型号:

MKS3P6VDC

Power/Signal Relay, 3PDT, Momentary, 0.224A (Coil), 6VDC (Coil), 1400mW (Coil), 10A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC100

Power/Signal Relay
OMRON

MKS3PAC110

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC12

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC120

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC200

Power/Signal Relay
OMRON

MKS3PAC220

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC230

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC24

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC240

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PAC6

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON

MKS3PDC100

Power/Signal Relay, 3PDT, Momentary, 0.014A (Coil), 100VDC (Coil), 1400mW (Coil), 10A (Contact), 250VDC (Contact), DC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
OMRON