M165-AW-12D [OMRON]
PUSHBUTTON SWITCH;型号: | M165-AW-12D |
厂家: | OMRON ELECTRONICS LLC |
描述: | PUSHBUTTON SWITCH 开关 |
文件: | 总13页 (文件大小:1516K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Indicator (Cylindrical 16-dia.)
M16
CSM_M16_DS_E_6_2
Cylindrical 16-dia. Indicator
• Same basic design as the A16 Pushbutton Switch.
Refer to Safety Precautions for All Pushbutton Switches/
Indicators and Safety Precautions on page 11.
List of Models
Appearance
Model
Rectangular
M16-J
Solder
Square
M16-A
M16-T
M16-@
terminals
Round
Voltage-
reduction
lighting
Screw-less
Clamp
M16-@
1
M16
Model Number Structure
Model Number Legend ..... The model numbers used to order sets of Units are illustrated below. One set comprises the Display, Case,
Lamp, and Socket.
For information on combinations, refer to Ordering Information on the following pages.
(1)
(2) (3)
(4)
(5)
(5) Terminal Type
M 1 6 5 - T R - 24D - S
Symbol
Terminal type
No symbol
Solder terminals
S
Screw-less Clamp
(1) Degree of Protection (2) Shape of Display (3) Color of Display (4) Light Source
Symbol
Protection
Symbol
5
12
24
5D
Type
Operating voltage Rated voltage
Symbol
Symbol
R
Shape
Rectangular
Square
Color
Red
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
6 VAC/VDC
14 VAC/VDC
28 VAC/VDC
5 VDC
No
symbol
J
A
T
IP40
Incandescent
lamp
G
Green
5
IP65 oil-resistant
Round
Y
Yellow
Pure yellow
White
5 5% VDC
PY
W
12D
24D
LED
12 5% VAC/VDC 12 VAC/VDC
24 5% VAC/VDC 24 VAC/VDC
PW
A
Pure white
Blue
Voltage Reduction Unit (24-V Built-in LED)
•
•
Color illuminated models
are also available (see
page 4).
Symbol
T1
Type
Operating voltage Rated voltage
100/110 VAC/VDC 110 VAC/VDC
200/220 VAC/VDC 220 VAC/VDC
LED
Order the parts separately.
T2
• Solder terminals are available only with 100-V models.
• Screw-less clamp connectors are used for 200-V models.
Sets................................. Select an Operation Unit Set (Operation Unit and Case) and a Socket Unit Set (Lamp and Socket Unit).
Display Unit
Rectangular, Square, Round
Lighted Models
Socket Unit Set with Voltage-reduction Lighting
Socket Unit Set with Screw-less Clamp Connector
Lamp
Voltage-reduction
Lamp
lighting
2
M16
Ordering Information
Ordering as a Set ................................. The model numbers used to order sets of Units are given in the following tables. One set comprises
the Display, Case, Lamp, and Socket.
M16@-J (Rectangular) Models
Solder Terminal Models
Degree of protection
Appearance
IP40
IP65 oil-resistant
M165-J@-5D
M165-J@-12D
M165-J@-24D
M165-J@-5
Display color symbol *
Lighting
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
5 VDC
M16-J@-5D
M16-J@-12D
M16-J@-24D
M16-J@-5
Rectangular (M16-J)
LED without Voltage
Reduction Unit
12 VAC/VDC
24 VAC/VDC
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
Incandescent lamp
M16-J@-12
M16-J@-24
M165-J@-12
M165-J@-24
* Enter the desired color symbol into the box in the model number.
M16@-A (Square) Models
Solder Terminal Models
Degree of protection
Appearance
IP40
IP65 oil-resistant
M165-A@-5D
M165-A@-12D
M165-A@-24D
M165-A@-5
Display color symbol *
Lighting
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
5 VDC
M16-A@-5D
M16-A@-12D
M16-A@-24D
M16-A@-5
Square (M16-A)
LED without Voltage
Reduction Unit
12 VAC/VDC
24 VAC/VDC
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
Incandescent lamp
M16-A@-12
M16-A@-24
M165-A@-12
M165-A@-24
* Enter the desired color symbol into the box in the model number.
M16@-T (Round) Models
Solder Terminal Models
Degree of protection
Appearance
IP40
IP65 oil-resistant
M165-T@-5D
M165-T@-12D
M165-T@-24D
M165-T@-5
Display color symbol *
Lighting
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
PW: pure white
5 VDC
M16-T@-5D
M16-T@-12D
M16-T@-24D
M16-T@-5
Round (M16-T)
LED without Voltage
Reduction Unit
12 VAC/VDC
24 VAC/VDC
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
R: red
Y: yellow
G: green
A: blue
W: white
PY: pure yellow
Incandescent lamp
M16-T@-12
M16-T@-24
M165-T@-12
M165-T@-24
Note: Neon lamps are not available with models that are ordered as a set. They must be ordered individually if required.
* Enter the desired color symbol into the box in the model number.
■ Accessories, replacements, and tools: Refer to the A16.
■ Ratings and characteristics: Refer to the A16.
■ Dimensions: Refer to pages 9 to 10.
Individual models: Refer to pages 4 to 7.
(The Display, Lamp, Case, and Switch can be ordered separately.)
3
M16
Ordering Information
Ordering Individually..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Display (Refer to page 6.)
Rectangular
Square
Round
Note: Use IP40 Displays in combination with IP40
Cases and use IP65 Displays in combination
with IP65 Cases.
The Display has a legend plate built in.
Case (Refer to page 7.)
Note: Display Units, which are combinations of Displays and
Cases, are also available.
Lighted Models
Lamp (Refer to page 7.)
LED
Incandescent Lamp
Socket (Refer to page 7.)
Solder Terminals
(Without Voltage Reduction Unit)
Note: Socket Units, which are combinations of Lamps and Sockets, are
also available.
•
For colored illumination, order the Display, Case, Lamp, and Socket Unit separately.
4
M16
Ordering Information
Sets.................................. Sets that combined a Display and Cases are also available.
Display Set
Appearance
Classification
Rectangular (2-way guard)
Model
A16-J@M
A16-A@M
A16-T@M
A165-J@M
A165-A@M
A165-T@M
IP40
Square (2-way guard)
Round (projecting model)
Rectangular (2-way guard)
Square (2-way guard)
Oil-resistant IP65
Round (projecting model)
Insert one of the following symbols into the box in the model number.
Symbol
Color
Red
Remarks
R
Y
Yellow
Pure yellow
Blue
LED and incandes-
cent lamps
PY
A
W
GY
G
White*
Green
Green
LED only
Incandescent only
* Use this pushbutton color if the illumination color of the LED is white or pure
white.
Socket Unit Sets with Incandescent Lamps
Socket Unit Sets with LEDs
Appearance
Classification
Model
M16-5
Appearance
Classification
Model
5 V
12 V
24 V
Solder terminals
M16-12
M16-24
1 2
M16- -
Solder terminals
@ @
Insert symbols into the boxes with circled numbers.
Socket Unit Sets with Voltage-reduction Lighting (Solder Terminals)
1
@
Appearance
Classification
Model
Symbol
Color
Red
R
Y
1
M16- -T1
100/110 VAC/VDC
@
Yellow
Blue
A
W
G
White
Green
Note: The LED has 24-VAC/VDC circuit built in.
Socket Unit Sets with Screw-less Clamp Connectors
2
@
Appearance
Classification
Model
1
2
-S
Operating
voltage
No voltage-reduction lighting
M16-
-
@ @
Symbol
Type
5D
5 VDC
1
Display
100/110 VAC/VDC M16- -T1-S
@
Voltage-reduc-
tion lighting
(See note.)
12D
24D
LED
12 VAC/VDC
24 VAC/VDC
1
200/220 VAC/VDC M16- -T2-S
@
Note: 1. The LED built into the 100-V model is 24 VAC/VDC.
2. The LED built into the 200-V model is high-intensity 24 VAC/VDC.
5
M16
Ordering Information
Ordering Individually..........................Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Display
For LED-lighted Models
Sealing
IP40
Square
IP65 oil-resistant
Square Round
Rectangular
Round
Rectangular
Appearance
Color of Display
Red
A16L-JR
A16L-JY
A16L-JPY
A16L-JGY
A16L-JW
A16L-JA
A16L-AR
A16L-AY
A16L-APY
A16L-AGY
A16L-AW
A16L-AA
A16L-TR
A165L-JR
A165L-JY
A165L-JPY
A165L-JGY
A165L-JW
A165L-JA
A165L-AR
A165L-AY
A165L-APY
A165L-AGY
A165L-AW
A165L-AA
A165L-TR
Yellow
A16L-TY
A16L-TPY
A16L-TGY
A16L-TW
A16L-TA
A165L-TY
A165L-TPY
A165L-TGY
A165L-TW
A165L-TA
Pure yellow
Green
White
Blue
Incandescent Lamps (With the exception of green, the Units are the same as for LEDs.)
Sealing
IP40
Square
IP65 oil-resistant
Square Round
Rectangular
Round
Rectangular
Appearance
Color of Display
Red
A16L-JR
A16L-JY
A16L-JPY
A16L-JG
A16L-JW
A16L-JA
A16L-AR
A16L-AY
A16L-APY
A16L-AG
A16L-AW
A16L-AA
A16L-TR
A165L-JR
A165L-JY
A165L-JPY
A165L-JG
A165L-JW
A165L-JA
A165L-AR
A165L-AY
A165L-APY
A165L-AG
A165L-AW
A165L-AA
A165L-TR
A165L-TY
A165L-TPY
A165L-TG
A165L-TW
A165L-TA
Yellow
A16L-TY
A16L-TPY
A16L-TG
A16L-TW
A16L-TA
Pure yellow
Green
White
Blue
■ Accessories, replacements, and tools: Refer to the A16.
■ Ratings and characteristics: Refer to the A16.
■ Dimensions: Refer to pages 9 to 10.
Ordering set combinations: Refer to page 3.
6
M16
Ordering Information
Ordering Individually ......................... Displays, Cases, Lamps, and Sockets can be ordered separately. Combinations that are not
available as sets can be created using individual parts. Also, store the parts as spares for
maintenance and repairs.
Lamp
LED
Operating voltage
High intensity
Color
5 VDC
12 VAC/VDC
24 VAC/VDC
Red
Yellow
Green
White *
Blue
A16-5DSR
A16-5DSY
A16-5DSG
A16-5DSW
A16-5DA
A16-12DSR
A16-12DSY
A16-12DSG
A16-12DSW
A16-12DA
A16-24DSR
A16-24DSY
A16-24DSG
A16-24DSW
A16-24DA
Pure white
A16-5DPW
A16-12DPW
A16-24DPW
* Use the white LED when the required illumination color is white or pure yellow.
Incandescent Lamp
Appearance
Operating voltage
5 VAC/VDC
Model
A16-5
12 VAC/VDC
A16-12
24 VAC/VDC
A16-24
Case
Appearance
Classification
Model number
Rectangular
Square
A16-CJM
A16-CAM
A16-CTM
A165-CJM
A165-CAM
IP40
Round
Rectangular
Square
IP65 oil-resistant
Round
A165-CTM
Socket
Appearance
Classification
Model number
M16-0
Solder terminals
PCB terminals
M16-0P
M16-S
Screw-Less Clamp
Solder terminals
100 V
100 V
200 V
M16-T1
M16-T1-S
M16-T2-S
Voltage-
reduction
lighting
Screw-less Clamp
Solder terminals
■ Accessories, replacements, and tools: Refer to the A16.
■ Ratings and characteristics: Refer to the A16.
■ Dimensions: Refer to pages 9 to 10.
Ordering set combinations: Refer to page 3.
7
M16
Specifications
Approved Standard Ratings
UL, cUL (File No. E76675)
LED:
24 VDC max.
Incandescent lamp: 24 VDC/VAC max.
Note: Certification has been obtained for the Socket Unit.
For detailed information on individual products that have received certification, consult your supplier.
Ratings
Ambient operating
−
10
35% to 85%RH
25 C to 65 C (with no icing or condensation)
°C to 55°C (with no icing or condensation)
temperature
Ambient operating
humidity
Ambient storage
temperature
−
°
°
Super-bright LED
Rated voltage
5 VDC
Rated current
Operating voltage
Built-in limiting resistance
Red, yellow, white: 300 Ω
Green, blue, pure white: 160 Ω
5 VDC 5%
8 mA
Red, yellow, white: 1 kΩ
12 VAC/VDC
24 VAC/VDC
12 VAC/VDC 5%
24 VAC/VDC 5%
Green, blue, pure white: 910 Ω
2.4 k
Ω
Incandescent Lamp
Rated voltage
6 VAC/VDC
Rated current
60 mA
Operating voltage
5 VAC/VDC
14 VAC/VDC
28 VAC/VDC
40 mA
12 VAC/VDC
24 mA
24 VAC/VDC
Characteristics
Screw-less Clamp
Item
Type
Screw-less Clamp
0.5 mm2 twisted wire or 0.8 mm-dia. solid wire
Recommended wire size
Twisted wire
Solid wire
0.3 mm2
0.5 mm dia. 0.8 mm dia. 1.0 mm dia.
10 N 20 N 30 N
10 1 mm
JIS C 2811 Terminal Blocks for Industrial Use
0.5 mm2
0.75 mm2
1.25 mm2
Usable wires
and tensile
strength
---
Tensile strength
40 N
Length of exposed wire
Compliant standards
8
M16
Dimensions (Refer to the A16 for details of panel cutout dimensions.)
(Unit: mm)
Rectangular
M16@-J
Solder terminals
Square
Packing (t0.5)
(for oil-resistant IP65 only)
Packing (t0.5)
(for oil-resistant IP65 only)
M16×1
M16@-A
Solder terminals
M16×1
14.6 dia.
14.6 dia.
18 dia.
18 dia.
4
4
Lamp terminals
Lamp terminals
10.8
10.8
6
21.1
28.5
6
21.1
28.5
9.3
9.3
18 15.1
4.85
4.85
18 15.1
21
24
15.1
18
Mounting nut
Lock ring
Mounting nut
Lock ring
Round
Packing (t0.5)
(for oil-resistant IP65 only)
M16@-T
M16×1
Solder terminals
18 dia.
15.1 dia.
14.6 dia.
18 dia.
4
10.8
4
Lamp terminals
10.8
Terminal Hole Dimensions
6
21.1
28.5
9.3
2.6
0.9
14.6 dia.
18 dia.
18
Lamp terminals
4.85
1.5
2.8
18
Mounting nut
Lock ring
9
M16
Dimensions
(Unit: mm)
Rectangular
50.1
42.7
M16@-J@-T1
Voltage-reduction lighting,
solder terminals
9.5
6
21.1
10.8
4
Direction-indication arrow
Panel Cutouts
9.8 18
0.5
Operation Unit
Case
Packing (t0.5)
16+0.2 dia.
24 min.
0
M16×1
Marking face
Lock ring
(for oil-resistant IP65 only)
Mounting ring
Socket
23 min.
(22.4)
20.6
15.1
18
8.816.6
2.8
21
24
Rectangular
M16@-J@-S
2
Screw-less Clamp
48.9
9.5
10.8
4
6
24
23.9
Panel Cutouts
16+0.2 dia.
M16×1
25 min.
0
Socket dismounting lever
Lock ring
Mounting ring
33 min.
(31.7) 27.4
23.5
15.1
18
21
24
Packing (t0.5)
(for oil-resistant IP65 only)
10
M16
Dimensions
(All units are in millimeters unless otherwise indicated.)
Terminal Arrangement
Solder Terminals
Screw-less Clamp
Voltage-reduction Lighting
Black
(BOTTOM VIEWꢀ
(BOTTOM VIEWꢀ
(BOTTOM VIEWꢀ
Side with TOP indicated
Side with TOP indicated
-
-
L +
L -
-
+
+
+
+
+
+
Red
The L+ is not shown on the Socket Unit.
Models with voltage-reduction lighting have a
circuit to reduce voltage built in.
Accessories, Replacements, and Tools
The accessories, replacements, and tools are also used with the A16 Pushbutton Switch. Refer to the A16 datasheet.
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches/Indicators and Safety Precautions for the A16.
Precautions for Correct Use
Mounting
Screw-less Clamps
Mounting Procedure
• When mounting the Case onto the Socket Unit, ensure that the
orientation is correct. Perform mounting with the dimple on the
Case and the TOP mark on the Socket Unit facing in the same
direction.
1. Strip a length of 10 mm off the end of the wire (allowable range:
10 1 mmꢀ.
2. Bunch wire strands together and straighten them.
3. Insert the wire into the insertion hole while pressing the release
button at the side of the hole. (Using a precision screwdriver is
recommended.ꢀ
TOP mark
4. Let go of the release button to lock the wire into place.
5. After locking, pull on the wire gently to confirm that it is securely
locked.
dimple
Removing Procedure
Case
Socket Unit
1. Remove wires by pulling them while pressing the release button.
Wiring
Note: When reusing wires that have already been locked, cut off the end of the
wire and strip the wire again before using.
• When using stranded wire, gather the ends of the strands together
before wiring.
• When wiring, insert the wire until it comes into contact with
something. After wiring is completed, pull on the wires to confirm
that they are connected securely.
• After wiring, ensure that continuous pressure is not applied to the
terminals.
• Refer to internal connections diagrams and confirm the terminal
numbers before performing wiring.
11
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.5
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2012 All Right Reserved.
相关型号: