LY4-24VAC [OMRON]

Power/Signal Relay, 4PDT, Momentary, 2256mW (Coil), 10A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Panel Mount;
LY4-24VAC
型号: LY4-24VAC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, 4PDT, Momentary, 2256mW (Coil), 10A (Contact), 30VDC (Contact), AC Input, AC/DC Output, Panel Mount

光电二极管 继电器
文件: 总13页 (文件大小:396K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General-purpose Relay  
LY  
A Miniature Power Relay  
• Equipped with arc barrier.  
• Dielectric strength: 2,000 V.  
• Built-in diode models added to the LY Series.  
• Single-pole and double-pole models are applicable to operating  
coils with ratings of 100/110 VAC, 110/120 VAC, 200/220 VAC,  
220/240 VAC, or 100/110 VDC).  
• Three-pole and four-pole models are applicable to operating  
coils with ratings of 100/110 VAC, 200/220 VAC, or 100/110  
VDC).  
LR  
Ordering Information  
Open Relays  
Type  
Contact form  
Upper-mounting  
Plug-in/solder  
terminals  
Plug-in/solder  
terminals with LED  
indicator  
PCB terminals  
Plug-in/solder  
terminals  
Standard  
SPDT  
DPDT  
LY1  
LY2  
LY1N  
LY1-0  
LY1F  
LY2N  
LY2-0  
LY2Z-0  
LY3-0  
LY4-0  
---  
LY2F  
LY2ZF  
LY3F  
LY4F  
---  
DPDT (bifurcated) LY2Z  
LY2ZN  
LY3N  
3PDT  
4PDT  
SPDT  
DPDT  
LY3  
LY4  
LY4N  
With built-in diode  
(DC only)  
LY1-D  
LY2-D  
LY1N-D2  
LY2N-D2  
LY2ZN-D2  
---  
---  
---  
DPDT (bifurcated) LY2Z-D  
---  
---  
3PDT  
4PDT  
SPDT  
DPDT  
LY3-D  
LY4-D  
---  
---  
---  
LY4N-D2  
---  
---  
---  
With built-in CR  
(AC only)  
---  
---  
LY2-CR  
LY2N-CR  
LY2ZN-CR  
---  
---  
DPDT (bifurcated) LY2Z-CR  
---  
---  
Note: 1. When ordering, add the rated coil voltage to the model number. Rated coil voltages are given in the coil ratings table.  
Example: LY2, 6 VAC  
Rated coil voltage  
2. Relays with #187 quick connect terminals are also available with SPDT and DPDT contact. Ask your OMRON representative for details.  
3. SEV models are standard Relays excluding DPDT (bifurcated) models.  
4. VDE- or LR- qualifying Relays must be specified when ordering.  
78  
General-purpose Relay LY  
Accessories (Order Separately)  
Sockets  
Poles  
Front-connecting Socket  
DIN track/screw terminals  
PTF08A-E, PTF08A  
PTF11A  
Back-connecting Socket  
Wrapping terminals  
Plug-in/solder terminals  
PT08  
PCB terminals  
1 or 2  
PT08QN  
PT08-0  
PT11-0  
PT14-0  
3
4
PT11  
PT14  
PT11QN  
PT14QN  
PTF14A-E, PTF14A  
Note: 1. For PTF08-E and PTF14A-E, see “Track Mounted Socket.”  
2. PTF@A (-E) Sockets have met UL and CSA standards: UL 508/CSA C22.2.  
Mounting Plates for Sockets  
Socket model  
For 1 Socket  
For 10 Sockets  
For 12 Sockets  
For 18 Sockets  
PYP-18  
PT08  
PYP-1  
---  
---  
---  
PT08QN  
PT11  
PTP-1-3  
PTP-1  
PTP-12  
---  
---  
---  
PT11QN  
PT14  
PTP-10  
PT14QN  
Socket-Hold-down Clip Pairings  
Relay type  
Poles  
Front-connecting Sockets  
Back-connecting Sockets  
Socket model Clip model  
Socket model  
Clip model  
Standard, bifurcated contacts oper- 1, 2  
PTF08A-E, PTF08A  
PTF11A  
PYC-A1  
PT08(QN), PT08-0  
PT11(QN), PT11-0  
PT14(QN), PT14-0  
PT08(QN), PT08-0  
PYC-P  
ation indicator, built-in diode  
3
4
PTF14A-E, PTF14A  
PTF08A-E, PTF08A  
CR circuit  
2
Y92H-3  
PYC-1  
Specifications  
Coil Ratings  
Single- and Double-pole Relays  
Rated voltage  
Rated current  
Coil  
resistance  
Coil inductance  
(reference value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consum.  
(approx.)  
50 Hz  
60 Hz  
Arm. OFF  
Arm. ON  
0.08 H  
0.33 H  
1.30 H  
5.66 H  
24.6 H  
32.1 H  
94.07 H  
136.40 H  
0.33 H  
1.37 H  
5.72 H  
21.0 H  
86.2 H  
% of rated voltage  
AC  
6 V  
214.1 mA  
106.5 mA  
53.8 mA  
183 mA  
12.2  
46 Ω  
180 Ω  
0.04 H  
0.17 H  
0.69 H  
3.22 H  
14.54 H  
19.20 H  
54.75 H  
83.50 H  
0.16 H  
0.73 H  
3.20 H  
10.6 H  
45.6 H  
80% max. 30% min. 110%  
1.0 to 1.2 VA  
(60 Hz)  
12 V  
91 mA  
24 V  
46 mA  
50 V  
25.7 mA  
22 mA  
788 Ω  
100/110 V  
110/120 V  
200/220 V  
220/240 V  
6 V  
11.7/12.9 mA  
9.9/10.8 mA  
6.2/6.8 mA  
4.8/5.3 mA  
150 mA  
10/11 mA  
8.4/9.2 mA  
5.3/5.8 mA  
4.2/4.6 mA  
3,750 Ω  
4,430 Ω  
12,950 Ω  
18,790 Ω  
40 Ω  
160 Ω  
650 Ω  
2,600 Ω  
11,000 Ω  
0.9 to 1 VA  
(60 Hz)  
DC  
10% min.  
0.9 W  
12 V  
75 mA  
24 V  
36.9 mA  
48 V  
18.5 mA  
100/110 V  
9.1/10 mA  
Note: See notes on the bottom of next page.  
General-purpose Relay LY  
79  
Three-pole Relays  
Rated voltage  
Rated current  
Coil  
resistance  
Coil inductance  
(reference value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consum.  
(approx)  
50 Hz  
310 mA  
60 Hz  
270 mA  
Arm. OFF  
Arm. ON  
0.05 H  
0.21 H  
0.79 H  
3.87 H  
18.5 H  
59.5 H  
0.21 H  
0.98 H  
3.87 H  
13.9 H  
54.3 H  
% of rated voltage  
AC  
6 V  
6.7 Ω  
24 Ω  
100 Ω  
410 Ω  
0.03 H  
0.12 H  
0.44 H  
2.24 H  
10.5 H  
34.8 H  
0.11 H  
0.45 H  
1.89 H  
8.53 H  
29.6 H  
80% max. 30% min. 110%  
1.6 to 2.0 VA  
(60 Hz)  
12 V  
159 mA  
134 mA  
67 mA  
33 mA  
24 V  
80 mA  
50 V  
38 mA  
100/110 V  
200/220 V  
6 V  
14.1/16 mA  
9.0/10.0 mA  
234 mA  
12.4/13.7 mA 2,300 Ω  
7.7/8.5 mA  
8,650 Ω  
25.7 Ω  
107 Ω  
410 Ω  
1,700 Ω  
8,500 Ω  
DC  
10% min.  
1.4 W  
12 V  
112 mA  
24 V  
58.6 mA  
28.2 mA  
12.7/13 mA  
48 V  
100/110 V  
Note: See notes under next table.  
Four-pole Relays  
Rated voltage  
Rated current  
Coil  
resistance  
Coil inductance  
(reference value)  
Must  
operate  
voltage  
Must  
release  
voltage  
Max.  
voltage  
Power  
consum.  
(approx)  
50 Hz  
386 mA  
60 Hz  
330 mA  
Arm. OFF  
Arm. ON  
0.04 H  
0.17 H  
0.67 H  
2.88 H  
17.3 H  
57.9 H  
0.21 H  
0.84 H  
2.91 H  
13.6 H  
63.7 H  
% of rated voltage  
AC  
6 V  
5 Ω  
20 Ω  
78 Ω  
0.02 H  
0.10 H  
0.38 H  
1.74 H  
10.5 H  
33.1 H  
0.09 H  
0.39 H  
1.41 H  
6.39 H  
32 H  
80% max. 30% min. 110%  
1.95 to  
2.5 VA  
(60 Hz)  
12 V  
199 mA  
170 mA  
24 V  
93.6 mA  
46.8 mA  
22.5/25.5 mA  
11.5/13.1 mA  
240 mA  
80 mA  
50 V  
40 mA  
350 Ω  
1,600 Ω  
6,700 Ω  
25 Ω  
100 Ω  
350 Ω  
1,600 Ω  
6,900 Ω  
100/110 V  
200/220 V  
6 V  
19/21.8 mA  
9.8/11.2 mA  
DC  
10% min.  
1.5 W  
12 V  
120 mA  
24 V  
69 mA  
48 V  
30 mA  
100/110 V  
15/15.9 mA  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and  
15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperatures of 23°C.  
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).  
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-  
sistor if required.  
80  
General-purpose Relay LY  
Contact Ratings  
Relay  
Single contact  
Inductive load Resistive load  
Bifurcated contacts  
2-pole  
1-pole  
2-, 3- or 4-pole  
Load  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ=0.4,  
L/R=7 ms)  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ=0.4,  
L/R=7 ms)  
(cosφ=0.4,  
(cosφ = 1)  
L/R=7 ms)  
Rated load  
110 VAC 15 A  
24 VDC 15 A  
110 VAC 10 A  
24 VDC 7 A  
110 VAC 10 A  
24 VDC 10 A  
110 VAC 7.5 A  
24 VDC 5 A  
110 VAC 5A  
24 VDC 5 A  
110 VAC 4 A  
24 VDC 4A  
Rated carry  
current  
15 A  
10 A  
7 A  
Max.  
switching  
voltage  
250 VAC  
125 VDC  
250 VAC  
125 VDC  
250 VAC  
125 VDC  
Max.  
15 A  
10 A  
7 A  
switching  
current  
Max.  
switching  
power  
1,700 VA  
360 W  
1,100 VA  
170 W  
1,100 VA  
240 W  
825 VA  
120 W  
550 VA  
120 W  
440 VA  
100 W  
Failure rate  
(reference  
value)*  
100 mA, 5 VDC  
100 mA, 5 VDC  
10 mA, 5 VDC  
*Note: P level: λ60 = 0.1 x 10-6/operation, reference value  
Characteristics  
Item  
All except Relays with bifurcated contacts  
50 mmax.  
Relays with bifurcated contacts  
Contact resistance  
Operate time  
25 ms max.  
Release time  
25 ms max.  
Max. operating frequency  
Mechanical: 18,000 operations/hr  
Electrical:  
1,800 operations/hr (under rated load)  
Insulation resistance  
Dielectric strength  
100 Mmin. (at 500 VDC)  
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity  
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity  
Vibration resistance  
Shock resistance  
Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)  
Destruction: 1,000 m/s2  
Malfunction: 200 m/s2  
Endurance  
Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)  
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)  
Electrical:  
Single-, three-, and four-pole: 200,000 operations min. (at 1,800 operations/hr  
under rated load)  
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)  
Ambient temperature*  
Operating:  
Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing)  
(–25°C to 70°C if carry current is 4 A or less)  
All other Relays: –25°C to 40°C (with no icing) (–25°C to 55°C if carry current is 4 A or less)  
Ambient humidity  
Weight  
Operating:  
5% to 85%  
Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g  
Note: 1. The values given above are initial values.  
2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element used.  
General-purpose Relay LY  
81  
Endurance Under Real Loads (reference only)  
LY1  
Rated voltage  
Load type  
AC motor  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
400 W, 100 VAC single-phase with 35-A in- ON for 10 s, OFF for 50 s  
rush current, 7-A current flow  
50,000 operations  
AC lamp  
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s  
3-A current flow  
100,000 operations  
25,000 operations  
100,000 operations  
1,500,000 operations  
800,000 operations  
500 W, 100 VAC with 78-A inrush current,  
5-A current flow  
Capacitor  
(2,000 µF)  
AC solenoid  
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 6 s  
rent flow  
50 VA with 2.5-A inrush current, 0.25-A  
current flow  
ON for 1 s, OFF for 2 s  
100 VA with 5-A inrush current, 0.5-A cur-  
rent flow  
LY2  
Rated voltage  
Load type  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
AC motor  
200 W, 100 VAC single-phase with 25-A in- ON for 10 s, OFF for 50 s  
rush current, 5-A current flow  
200,000 operations  
AC lamp  
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s  
3-A current flow  
80,000 operations  
10,000 operations  
150,000 operations  
1,000,000 operations  
500,000 operations  
Capacitor  
(2,000 µF)  
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s  
rent flow  
24 VDC with 20-A inrush current, 1-A cur-  
rent flow  
AC solenoid  
50 VA with 2.5-A inrush current, 0.25-A  
current flow  
ON for 1 s, OFF for 2 s  
100 VA with 5-A inrush current, 0.5-A cur-  
rent flow  
LY4  
Rated voltage  
Load type  
Conditions  
Operating frequency  
Electrical life  
100 VAC  
AC motor  
200 W, 200 VAC triple-phase with 5-A in- ON for 10 s, OFF for 50 s  
rush current, 1-A current flow  
500,000 operations  
750 W, 200 VAC triple-phase with 18-A in-  
rush current, 3.5 A current flow  
70,000 operations  
50,000 operations  
5,000 operations  
AC lamp  
300 W, 100 VAC with 51-A inrush current, ON for 5 s, OFF for 55 s  
3-A current flow  
Capacitor  
(2,000 µF)  
24 VDC with 50-A inrush current, 1-A cur- ON for 1 s, OFF for 15 s  
rent flow  
24 VDC with 20-A inrush current, 1-A cur- ON for 1 s, OFF for 2 s  
rent flow  
200,000 operations  
1,000,000 operations  
500,000 operations  
AC solenoid  
50 VA with 2.5-A inrush current, 0.25-A  
current flow  
ON for 1 s, OFF for 2 s  
100 VA with 5-A inrush current, 0.5-A cur-  
rent flow  
82  
General-purpose Relay LY  
Approved Standards  
UL 508 Recognitions (File No. 41643)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 125 VDC  
Contact ratings  
Operations  
6 x 103  
25 x 103  
6 x 103  
1
2
15 A, 30 VDC (Resistive)  
15 A, 240 VAC (General use)  
TV-5, 120 VAC  
1/2 HP, 120 VAC  
15 A, 28 VDC (Resistive)  
15 A, 120 VAC (Resistive)  
12 A, 240 VAC (General use)  
1/2 HP, 120 VAC  
25 x 103  
6 x 103  
3 and 4  
10 A, 30 VDC (Resistive)  
10 A, 240 VAC (General use)  
1/3 HP, 240 VAC  
CSA 22.2 No. 14 Listings (File No. LR31928)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 125 VDC  
Contact ratings  
Operations  
6 x 103  
25 x 103  
6 x 103  
1
15 A, 30 VDC (Resistive)  
15 A, 120 VAC (General use)  
1/2 HP, 120 VAC  
TV-5, 120 VAC  
2
15 A, 30 VDC (Resistive)  
15 A, 120 VAC (Resistive)  
1/2 HP, 120 VAC  
TV-3, 120 VAC  
3 and 4  
10 A, 30 VDC (Resistive)  
10 A, 240 VAC (General use)  
SEV Listings (File No. D3,31/137)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
6 x 103  
1
6 to 240 VAC  
6 to 125 VDC  
15 A, 24 VDC  
15 A, 220 VAC  
2 to 4  
10 A, 24 VDC  
10 A, 220 VAC  
TÜV (File No. R9251226) (IEC255)  
No. of poles  
Coil ratings  
6 to 125 VDC  
6 to 240 VAC  
Contact ratings  
Operations  
100 x 103  
1 to 4  
LY1, LY1-FD  
15 A, 110 VAC (cosφ=1)  
10 A, 110 VAC (cosφ=0.4)  
LY2, LY2-FD, LY3, LY3-FD, LY4,  
LY4-FD  
10 A, 110 VAC (cosφ=1)  
7.5 A, 110 VAC (cosφ=0.4)  
VDE Recognitions (No. 9903UG and 9947UG)  
No. of poles  
Coil ratings  
Contact ratings  
Operations  
200 x 103  
1
6, 12, 24, 50, 110, 220 VAC  
6, 12, 24, 48, 110 VDC  
10 A, 220 VAC (cosφ=1)  
7 A, 220 VAC (cosφ=0.4)  
10 A, 28 VDC (L/R=0 ms)  
7 A, 28 VDC (L/R=7 ms)  
2
7 A, 220 VAC (cosφ=1)  
4 A, 220 VAC (cosφ=0.4)  
7 A, 28 VDC (L/R=0 ms)  
4 A, 28 VDC (L/R=7 ms)  
LR Recognitions (No. 563KOB-204523)  
No. of poles  
Coil ratings  
6 to 240 VAC  
6 to 110 VDC  
Contact ratings  
2, 4  
7.5 A, 230 VAC (PF0.4)  
5 A, 24 VDC (L/R=7 ms)  
General-purpose Relay LY  
83  
Engineering Data  
LY1  
Maximum Switching Power  
Endurance  
AC resistive load  
15  
10  
Life: 200,000  
operations  
5
AC  
(cosφ =  
10,000  
5,000  
0.4)  
110 VAC resistive load  
1
DC L/R =  
7 ms  
24 VDC resistive load  
0.5  
1,000  
500  
DC resistive load  
24 VDC  
(L/R = 7ms)  
110 VAC (cosφ = 0.4)  
0.1  
100  
10  
100  
500 1,000  
0
2
4
6
8
10 12 14 16 18 20  
Switching voltage (V)  
Switching current (A)  
LY2  
Maximum Switching Power  
Endurance  
AC resistive load  
10  
5
Life: 500,000  
operations  
AC  
(cosφ =  
1,0000  
0.4)  
5,000  
24 VDC resistive load  
110 VAC resistive load  
1
DC L/R =  
7 ms  
0.5  
1,000  
500  
DC resistive load  
110 VAC (cosφ = 0.4)  
0.1  
24 VDC (L/R = 7ms)  
100  
0
2
4
6
8
10 12 14 16 18 20  
10  
100  
500 1,000  
Switching current (A)  
Switching voltage (V)  
LY3 and LY4  
Maximum Switching Power  
Endurance  
AC resistive load  
10  
5
Life: 200,000  
operations  
AC  
1,0000  
(cosφ =  
0.4)  
5,000  
24 VDC resistive load  
110 VAC resistive load  
1
DC L/R =  
7 ms  
1,000  
500  
0.5  
110 VAC (cosφ = 0.4)  
DC resistive load  
0.1  
100  
24 VDC (L/R = 7ms)  
500 1,000  
10  
100  
0
2
4
6
8
10 12 14 16 18 20  
Switching current (A)  
Switching voltage (V)  
84  
General-purpose Relay LY  
LY2Z  
Maximum Switching Power  
Endurance  
AC resistive load  
10  
5
AC  
(cosφ = 0.4)  
24 VDC resistive load  
10,000  
5,000  
110 VAC resistive load  
DC resistive load  
110 VAC (cosφ = 0.4)  
1
1,000  
500  
0.5  
DC L/R =  
7 ms  
24 VDC (L/R = 7ms)  
100  
0
Life: 500,000 operations  
0
2
4
6
8
10  
10  
50 100  
500 1,000  
Switching voltage (V)  
Switching current (A)  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
Relays with Solder/Plug-in Terminals  
LY1  
LY1N (-D2)  
LY1-D  
0.5  
Eight, 2-dia. holes  
28 max.  
5
3
21.5  
max.  
6.4  
36 max.  
Terminal Arrangement/Internal Connections (Bottom View)  
LY1N  
LY1  
LY1-D  
DC Model  
AC Model  
LY1N-D2  
Note: The DC models have polarity.  
General-purpose Relay LY  
85  
LY2  
LY2Z  
Terminal Arrangement/Internal  
Connections (Bottom View)  
LY2-D  
LY2N  
LY2Z-D  
LY2ZN  
LY2N-D2  
LY2ZN-D2  
LY2(Z)-D  
LY2(Z)  
0.5  
Eight, 3-dia. holes  
5
28 max.  
3
21.5 max.  
6.4  
36 max.  
LY2(Z)N  
LY2(Z)N-D2  
DC Model  
AC Model  
Note: The DC models have polarity.  
LY3Z  
LY3N  
LY3-D  
0.5  
28 max.  
5
3
31.5 max.  
36.5 max.  
6.4  
Eleven, 3-dia. holes  
Terminal Arrangement/Internal Connections (Bottom View)  
LY3-D LY3N  
LY3  
DC Model  
AC Model  
Note: The DC models have polarity.  
86  
General-purpose Relay LY  
Terminal Arrangement/Internal Connections  
(Bottom View)  
LY4  
LY4-D  
LY4N  
LY4N-D2  
LY4  
LY4-D  
0.5  
28 max.  
5
3
41.5 max.  
Fourteen,  
3-dia. holes  
36 max.  
6.4  
LY4N  
LY4N-D2  
DC Model  
AC Model  
Note: The DC models have polarity.  
LY2-CR  
LY2Z-CR  
LY2N-CR  
LY2ZN-CR  
Terminal Arrangement/Internal Connections  
(Bottom View)  
LY2(Z)N-CR  
LY2(Z)-CR  
0.5  
Eight, 3-dia.  
holes  
28 max.  
5
3
CR Element  
21.5  
max.  
53 max.  
C: 0.033 µF  
R: 120 Ω  
6.4  
Model: LY2N-CR  
Relays with PCB Terminals  
LY1-0 LY3-0  
LY2-0 LY4-0  
PC Board Holes (Bottom View)  
14.2  
10  
14.2  
10  
10 10 10  
10 10  
0.5  
4.1  
5.5  
28 max.  
5.75  
4.6  
2
13.15  
7.15  
1
21.5  
max.  
36 max.  
4.5 (see note 2)  
5.3  
3.4  
Five,  
2.5-dia.  
holes  
5.3  
3.4  
Fourteen,  
2.5-dia.  
holes  
Eleven,  
2.5-dia.  
holes  
Eight,  
2.5-dia.  
holes  
Note: 1. The above model is the LY2-0.  
2. This figure is 6.4 for the LY1-0  
Note: 1. The tolerance for the above figures is 0.1 mm.  
2. Besides the terminals, some part of the LY1-0 car-  
ries current. Due attention should be paid when  
mounting the LY1-0 to a double-sided PC board.  
General-purpose Relay LY  
87  
Upper-mounting Relays  
LY1F  
LY2F  
2
Mounting Holes  
22.5 max.  
0.5  
44  
max.  
29  
max.  
38  
38 0.1  
5
3
Eight, 2-dia.  
holes (see note)  
Two, 3.5-dia.  
holes (or Two  
M3 holes)  
35.5 max.  
6.4  
3.5  
Note: 1. Eight 3-dia. holes should apply to  
the LY2F model.  
LY3F  
32 max.  
2
3.5  
0.5  
28.5  
max.  
38 0.1  
38  
44 max.  
5
3
Eleven,  
3-dia. holes  
Two, 3.5-dia. holes  
(or two, M3 holes)  
36 max.  
6.4  
LY4F  
Mounting holes  
41.5 max.  
3.5  
Two, 3.5 dia. holes (or  
two, M3 holes)  
2
0.5  
5
44  
max.  
28  
max.  
38  
38 0.1  
Fourteen,  
3-dia. holes  
28 0.1  
28  
3
35.5 max.  
6.4  
88  
General-purpose Relay LY  
Mounting Height with Socket  
The following Socket heights should be maintained.  
Back-connecting  
Front-connecting  
LY  
40 (57)  
LY  
67 (84)  
Note: 1. The PTF@A (-E) can be track-mounted or screw-mounted.  
71 (see note)  
2. For the LY@-CR (CR circuit built-in type) model, this figure  
should be 88.  
PT@  
PTF@A (-E)  
Sockets  
PTF08A-E  
PTF11A  
PTF14A-E  
PT08  
PT11  
PT14  
PT08QN  
PT14-0  
PT14QN  
PT11QN  
PT08-0  
PT11-0  
Mounting Plates for Back-connecting  
PYP-1  
PTP-1-3  
PTP-1  
PYP-18  
Two, 3.4-dia. holes  
49  
42 0.1  
492  
59  
R5  
7.7  
42 0.1 49  
7.7  
17 x 27.4 = 465.8 0.6  
21.6  
Four,  
3.4-dia.  
holes  
4.5  
3.4  
72 elliptical holes  
5.1  
42  
49  
42 0.1 49  
R1.7  
7.7  
42 0.1 49  
28  
R5  
52 0.1  
t=1.6  
Four, 3.4-dia. holes  
t=1.6  
t=1.6  
21.6  
17 x 27.4 = 465.8 0.6  
17 x 27.4 = 465.8 0.6  
t=1.6  
PTP-10  
PTP-12  
7.4  
40 elliptical holes  
7.7  
9 x 49.4 = 444.6 0.6  
48 elliptical holes  
11 x 39.4 = 433.4 0.6  
49  
42 0.1  
7.7  
42 0.1 49  
R1.7  
3.4  
3.4  
4.5  
1.1  
Twelve, square holes  
t=1.6  
4.5  
R2.25  
7.4  
9 x 49.4 = 444.6 0.6  
11 x 39.4 = 433.4 0.6  
11 x 39.4 = 433.4 0.6  
492  
9 x 49.4 = 444.6 0.6  
492  
23.7  
29.3  
t=1.6  
General-purpose Relay LY  
89  
Hold-down Clips  
Hold-down clips are used to hold Relays to Sockets and prevent them from coming loose due to vibration or shock.  
Used with Socket  
PYC-P  
Used with Socket  
mounting plate  
For CR circuit built-in Relay  
PYC-1  
PYC-A1  
PYC-S  
Y92H-3  
Precautions  
Refer to page 11 for general precautions.  
Connections  
Do not reverse polarity when connecting DC-operated Relays with  
built-in diodes or indicators.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
In the interest of product improvement, specifications are subject to change without notice.  
Cat. No. J002-E1-10  
90  
General-purpose Relay LY  

相关型号:

LY4-AC100/110

Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY4-AC110

Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Socket Mount
OMRON

LY4-AC110/120

Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY4-AC12

POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 1200mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT
OMRON

LY4-AC120

Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Socket Mount
OMRON

LY4-AC200/220

Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY4-AC220

Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Socket Mount
OMRON

LY4-AC220/240

Power/Signal Relay, 4PDT, Momentary, 1200mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Panel Mount
OMRON

LY4-AC24

POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 1200mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT
OMRON

LY4-AC240

Power/Signal Relay, 4PDT, Momentary, 2500mW (Coil), 10A (Contact), 24VDC (Contact), AC Input, AC/DC Output, Socket Mount
OMRON

LY4-AC50

POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 1200mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT
OMRON

LY4-AC6

POWER/SIGNAL RELAY, 4PDT, MOMENTARY, 1200mW (COIL), 10A (CONTACT), 24VDC (CONTACT), PANEL MOUNT
OMRON