General Purpose Relay  
G7L  
• Ideally suited for high-inrush fluid pump controls: pool/spa, water  
processing, emergency, chemical industry, etc.  
• High-capacity, high-withstand voltage relay with no contact chatter-  
ing for momentary voltage drops up to 50% of rated voltage.  
• UL Class B construction standard.  
• Wide-range AC-activated coil that handles 100 to 120 VAC at either  
50 or 60 Hz.  
• Miniature hinge for maximum switching capacity, particularly for in-  
ductive loads.  
• Flame resistant materials (UL94V-0-qualifying) used for  
all insulation material.  
• Quick-connect, screw, and PCB terminals available.  
• Standard models are UL, CSA, and TUV approved;  
VDE/IEC 950 versions are now available. Meet pollution degree 3,  
Material Group II & III.  
Ordering Information  
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).  
Type  
Contact form  
Model  
Quick-connect terminal  
G7L-1A-T-CB  
G7L-2A-T-CB  
G7L-1A-TJ-CB  
G7L-2A-TJ-CB  
G7L-1A-TUB-CB  
G7L-2A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-2A-TUBJ-CB  
Screw terminal  
PCB terminal  
E bracket (see note 1)  
SPST-NO  
G7L-1A-B-CB  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
G7L-2A-B-CB  
G7L-1A-BJ-CB  
G7L-2A-BJ-CB  
G7L-1A-BUB-CB  
G7L-2A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-2A-BUBJ-CB  
E bracket (see note 1)  
(with test button)  
Upper bracket  
Upper bracket  
(with test button)  
PCB mounting  
G7L-1A-P-CB  
G7L-2A-P-CB  
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.  
2. For VDE approved versions, please consult OMRON.  
General Purpose Relay G7L  
305  
Model Number Legend  
G7L- ❏ ❏ - ❏ ❏ ❏ ❏  
1 2 3 4 5 6  
1. Contact form  
1A:SPST-NO  
3. Mounting construction  
No symbol:E bracket type  
UB:Upper bracket type  
5. 80: VDE approved version  
(includes UL, CSA and TÜV)  
2A:DPST-NO  
6. CB: Class B insulation  
7. Rated coil voltage  
2. Terminal shape  
T:Quick-connect terminals  
P:PCB terminals  
4. Special functions  
No symbol:Without test button  
J:With test button  
B:Screw terminals  
Accessories  
Quick-connect Terminals  
Description  
Model  
Model  
Contact form  
SPST-NO  
G7L-1A-TJ  
DPST-NO  
G7L-2A-TJ  
E-brackets  
Track mounting adaptor  
Front connecting socket  
G7L-1A-T  
G7L-2A-T  
R99-07G5D  
P7LF-D  
P7LF-06  
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.  
Screw Terminals  
Description  
Model  
Model  
Contact form  
SPST-NO  
G7L-1A-BJ  
DPST-NO  
G7L-2A-BJ  
E-brackets  
G7L-1A-B  
G7L-2A-B  
R99-07G5D  
Track mounting adaptor  
Terminal Cover  
P7LF-D  
P7LF-C  
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.  
Specifications  
Contact Data  
Load  
G7L-1A-T, G7L-1A-B  
G7L-2A-T, G7L-2A-B  
Resistive load Inductive load  
(cosφ = 1) (cosφ = 0.4)  
G7L-1A-P, G7L-2A-P  
Resistive load  
Inductive load  
(cosφ = 0.4)  
25 A, 220 VAC  
Resistive load  
(cosφ = 1)  
Inductive load  
(cosφ = 0.4)  
(cosφ = 1)  
30 A, 220 VAC  
AgSnIn  
Rated load  
Contact material  
Carry current  
20 A, 220 VAC  
30 A  
25 A  
25 A  
20 A  
Max. operating voltage 250 VAC  
Max. operating current 30 A  
Max. switching capacity 6,600 VA  
20 A  
5,500 VA  
4,400 VA  
Min. permissible load  
100 mA, 5 VDC (please inquire for lower minimum rating)  
Note: P level: λ60 = 0.1 x 10-6 operation.  
Coil Internal Circuit  
DC operating coil  
AC operating coil  
306  
General Purpose Relay G7L  
Coil Data  
AC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
Must operate  
75% max.  
Must release  
% of rated voltage  
15% min.  
Max. voltage  
110% max.  
Power  
(Ω)  
consumption  
6
283  
142  
18.90  
Approx.1.70  
to 2.50 VA  
12  
75  
24  
71  
303  
50  
34  
1,310  
5,260  
21,000  
100/120  
200/240  
17.00/20.40  
8.50/10.20  
75 volts  
18 volts  
36 volts  
132 volts  
264 volts  
150 volts  
DC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
(Ω)  
Must operate  
75% max.  
Must release  
% of rated voltage  
15% min.  
Max. voltage  
110% max.  
Power  
consumption  
6
317  
158  
79  
18.90  
75  
Approx.1.90 W  
12  
24  
48  
100  
303  
40  
1,220  
5,260  
19  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated cur-  
rent and ±15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).  
Characteristics  
Contact resistance  
50 mΩ max.  
Operate time  
30 ms max.  
Release time  
30 ms max.  
Max. operating  
frequency  
Mechanical  
Electrical  
1,800 operations/hour  
1,800 operations/hour (under rated load)  
Insulation resistance  
Dielectric strength  
1,000 MΩ min. (at 500 VDC)  
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts  
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole  
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)  
Between coil and contact: 10,000 V min./12,000 V typ. (impulse wave used: 1.20 x 50 μs)  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
Impulse withstand voltage  
Vibration  
Mechanical  
durability  
Malfunction  
durability  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
1,000 m/s2 (approx. 100 G)  
Shock  
Mechanical  
durability  
1,000 m/s2 (approx.10 G)  
Malfunction  
durability  
Life expectancy  
Mechanical  
Electrical  
1,000,000 operations min. (at 1,800 operations/hour)  
100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)  
-25° to 60°C (-13° to 140°F)  
Ambient temperature  
Humidity  
35% to 85% RH  
Weight  
Quick-connect terminal type: approx. 90 g (3.17 oz)  
PCB terminal type: approx. 100 g (3.52 oz)  
Screw terminal type: approx. 120 g (4.23 oz)  
Note: Data shown are of initial value.  
General Purpose Relay G7L  
307  
Characteristic Data  
Maximum switching capacity  
Electrical service life  
Switching current (A)  
Switching voltage (V)  
Dimensions  
Unit: mm (inch)  
Relays  
G7L-1A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
308  
General Purpose Relay G7L  
G7L-1A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
*E bracket must be ordered separately.  
General Purpose Relay G7L  
309  
Unit: mm (inch)  
G7L-1A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
310  
General Purpose Relay G7L  
G7L-1A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
General Purpose Relay G7L  
311  
Unit: mm (inch)  
G7L-1A-BUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUBJ  
Mounting holes  
(Bottom view)  
Terminal arrangement/  
Internal connections  
(Top view)  
G7L-1A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
312  
General Purpose Relay G7L  
Accessories  
E bracket  
R99-07G5D  
Mounting holes  
(Bottom view)  
Adaptor  
P7LF-D  
Mounting holes  
(Bottom view)  
Front connecting socket  
P7LF-06  
Mounting holes  
(Bottom view)  
Note: 1. To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket.  
2. The P7LF-06 is panel or track mountable.  
General Purpose Relay G7L  
313  
Unit: mm (inch)  
Cover  
P7LF-C  
Note: P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals.  
Mounting track  
PFP-100N, PFP-50N  
(Conforming to EN 50022)  
PFP-100N2  
(Conforming to EN 50022)  
16  
7.3 0.15  
35 0.3  
4.5  
4.5  
27  
35 0.3  
29.2  
1.5  
24  
27 0.15  
1
15 25  
25  
25  
25 15  
15 25  
25  
25  
25  
*
1
15 (5)  
10  
10  
10  
10  
1000  
4
1000 (500)*  
* The figure in parenthesis is for PFP-50N.  
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.  
2. L = Length  
PFP-100N L = 1 m (39.00 in)  
PFP-50N  
L = 50 cm (19.60 in)  
PFP-100N2 L = 1 m (39.00 in)  
End plate  
PFP-M  
Spacer  
PFP-S  
314  
General Purpose Relay G7L  
Approvals  
UL Recognized (File No. E41643) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C  
Type  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
Contact form  
Terminal type  
Contact ratings  
30 A, 277 VAC, General Use, 100,000 ops  
1.5 kW, 120 VAC, Tungsten, 6,000 ops  
1.5 HP, 120 VAC, 6,000 ops  
SPST-NO  
Quick-connect  
3 HP, 277 VAC, 6,000 ops  
20 FLA/120 LRA, 120 VAC, 30,000 ops  
17 FLA/102 LRA, 265 VAC, 30,000 ops  
TV-10, 120 VAC, 25,000 ops  
Screw  
PCB  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
Screw  
PCB  
Note: Contact Omron for actual ratings marked on G7L relays  
TÜV (File No. R9251551)  
Type  
Contact form  
Coil ratings  
Terminal type  
Contact ratings  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
SPST-NO  
6, 12, 24, 48,  
100, 110, 200,  
220 VDC  
Quick-connect  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
12, 24, 50,  
100/120, 200/240  
VAC  
Screw  
30 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
30 A, 240 VAC, (cosφ = 0.4)  
PCB  
20 A, 240 VAC, (cosφ = 1)  
20 A, 240 VAC, (cosφ = 0.4)  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
Screw  
PCB  
25 A, 240 VAC, (cosφ = 1)  
25 A, 240 VAC, (cosφ = 0.4)  
20 A, 240 VAC, (cosφ = 1)  
20 A, 240 VAC, (cosφ = 0.4)  
VDE recognized type (Licence no. 1530 UG)  
Note: 1. Please consult OMRON for details of VDE approvals.  
2. The G7L relay conforms to the following standards:  
Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83  
DIN VDE 0435 Teil 201 A1/05. 90  
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81  
DIN EN 60 950/VDE 0805/11. 93  
EMC:  
prEN 50082-2, EN 55022  
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics  
individually defined in this catalog.  
4. In the interest of product improvement, specifications are subject to change.  
5. Suffix T130 rated at 130°C  
6. Pollution degree 3, Material Group II & III.  
General Purpose Relay G7L  
315  
Precautions  
Handling  
Operating Coil  
To preserve initial performance, do not drop or otherwise subject  
As a rule, either a battery or a DC power supply with a maximum  
5% ripple is used for the operating voltage for DC relays. Before  
using a rectified AC supply, confirm that the ripple is not greater  
than 5%. Ripple greater than this can lead to variations in the oper-  
ating and reset voltages.  
the power relay to shock.  
The case is not designed to be removed during normal handling  
and operation. Doing so may affect performance.  
Use the power relay in a dry environment free from excessive dust,  
SO2, H2S, or organic gas.  
As excessive ripple can generate beats, the insertion of a  
smoothing capacitor is recommended as shown below.  
Do not allow a voltage greater than the maximum allowable coil  
voltage to be applied continuously.  
Do not use the power relay outside of specified voltages and cur-  
rents.  
Do not allow the ambient operating temperature to exceed the  
specified limit.  
Installation  
Although there are not specific limits on the installation site, it  
should be as dry and dust-free as possible.  
PCB terminal-equipped relays weigh approximately 100 g. Be sure  
that the PCB is strong enough to support them. We recommend  
dual-side through-hole PCBs to reduce solder cracking from heat  
stress.  
Quick-connect terminals can be connected to fast on receptacle  
#250 and positive-lock connectors.  
Allow suitable slack on leads when wiring, and do not subject the  
terminals to excessive force.  
When driving a transistor, check the leakage current and connect a  
bleeder resistor if necessary.  
Cleaning PCB Terminals  
PCB terminals have semi-sealed construction which prevents flux  
from entering the relay base. It is recommended that the user  
should apply a tape seal over the vent hole prior to wave soldering  
or cleaning. The tape should then be removed after processing.  
Momentary voltage drops on coil input voltage should not exceed  
one second duration after contact mating with no shock or vibra-  
tion.  
Applications  
Compressors for package air conditioners and heater switching  
controllers  
Switching controllers for power tools or motors  
Power controllers for water heaters  
Power controllers for dryers  
Lamp control, motor drivers, and power supply switching in copy  
machines, facsimiles, and other OA equipment  
Lighting controllers  
Power controllers for packers or food processing equipment  
Magnetron control in microwaves  
316  
General Purpose Relay G7L  
(b) Use in consumer Products or any use in significant quantities.  
(c) Energy control systems, combustion systems, railroad systems, aviation systems,  
medical equipment, amusement machines, vehicles, safety equipment, and  
installations subject to separate industry or government regulations.  
(d) Systems, machines, and equipment that could present a risk to life or property.  
3. Prohibited Use: NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING  
SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE  
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE  
WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
4. Motorized Vehicle Application: USE OF ANY PRODUCT/S FOR A MOTORIZED  
VEHICLE APPLICATION MUST BE EXPRESSLY STATED IN THE SPECIFICATION BY  
SELLER.  
5. Programmable Products: Seller shall not be responsible for the Buyer's programming of  
a programmable Product.  
Omron Electronic Components, LLC  
Terms and Conditions of Sales  
I. GENERAL  
1. Definitions: The words used herein are defined as follows.  
(a) Terms:  
(b) Seller:  
(c) Buyer:  
These terms and conditions  
Omron Electronic Components LLC and its subsidiaries  
The buyer of Products, including any end user in section III through VI  
(d) Products: Products and/or services of Seller  
(e) Including: Including without limitation  
2. Offer; Acceptance: These Terms are deemed part of all quotations, acknowledgments,  
invoices, purchase orders and other documents, whether electronic or in writing, relating  
to the sale of Products by Seller. Seller hereby objects to any Terms proposed in Buyer's  
purchase order or other documents which are inconsistent with, or in addition to, these  
Terms.  
3. Distributor: Any distributor shall inform its customer of the contents after and including  
section III of these Terms.  
IV. WARRANTY AND LIMITATION  
1. Warranty: Seller's exclusive warranty is that the Products will be free from defects in  
materials and workmanship for a period of twelve months from the date of sale by Seller  
(or such other period expressed in writing by Seller). SELLER MAKES NO WARRANTY  
OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT ALL OTHER WARRANTIES,  
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE OF THE PRODUCTS.  
2. Buyer Remedy: Seller's sole obligation hereunder shall be to replace (in the form  
originally shipped with Buyer responsible for labor charges for removal or replacement  
thereof) the non-complying Product or, at Seller's election, to repay or credit Buyer an  
amount equal to the purchase price of the Product; provided that there shall be no  
liability for Seller or its affiliates unless Seller's analysis confirms that the Products were  
correctly handled, stored, installed and maintained and not subject to contamination,  
abuse, misuse or inappropriate modification. Return of any Products by Buyer must be  
approved in writing by Seller before shipment.  
3. Limitation on Liability: SELLER AND ITS AFFILIATES SHALL NOT BE LIABLE FOR  
SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSS OF  
PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED  
WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT,  
WARRANTY, NEGLIGENCE OR STRICT LIABILITY. FURTHER, IN NO EVENT SHALL  
LIABILITY OF SELLER OR ITS AFFILITATES EXCEED THE INDIVIDUAL PRICE OF  
THE PRODUCT ON WHICH LIABILITY IS ASSERTED.  
4. Indemnities: Buyer shall indemnify and hold harmless Seller, its affiliates and its  
employees from and against all liabilities, losses, claims, costs and expenses (including  
attorney's fees and expenses) related to any claim, investigation, litigation or proceeding  
(whether or not Seller is a party) which arises or is alleged to arise from Buyer's acts or  
omissions under these Terms or in any way with respect to the Products.  
II. SALES  
1. Prices; Payment: All prices stated are current, subject to change without notice by Seller.  
Buyer agrees to pay the price in effect at the time the purchase order is accepted by  
Seller. Payments for Products received are due net 30 days unless otherwise stated in  
the invoice. Buyer shall have no right to set off any amounts against the amount owing in  
respect of this invoice.  
2. Discounts: Cash discounts, if any, will apply only on the net amount of invoices sent to  
Buyer after deducting transportation charges, taxes and duties, and will be allowed only  
if (a) the invoice is paid according to Seller's payment terms and (b) Buyer has no past  
due amounts owing to Seller.  
3. Interest: Seller, at its option, may charge Buyer 1.5% interest per month or the maximum  
legal rate, whichever is less, on any balance not paid within the stated terms.  
4. Orders: Seller will accept no order less than 200 U.S. dollars net billing.  
5. Currencies: If the prices quoted herein are in a currency other than U.S. dollars, Buyer  
shall make remittance to Seller at the then current exchange rate most favorable to  
Seller; provided that if remittance is not made when due, Buyer will convert the amount  
to U.S. dollars at the then current exchange rate most favorable to Seller available  
during the period between the due date and the date remittance is actually made.  
6. Governmental Approvals: Buyer shall be responsible for all costs involved in obtaining  
any government approvals regarding the importation or sale of the Products.  
7. Taxes: All taxes, duties and other governmental charges (other than general real  
property and income taxes), including any interest or penalties thereon, imposed directly  
or indirectly on Seller or required to be collected directly or indirectly by Seller for the  
manufacture, production, sale, delivery, importation, consumption or use of the Products  
sold hereunder (including customs duties and sales, excise, use, turnover and license  
taxes) shall be charged to and remitted by Buyer to Seller.  
V. INFORMATION; ETC.  
1. Intellectual Property: The intellectual property embodied in the Products is the exclusive  
property of Seller and its affiliates and Buyer shall not attempt to duplicate it in any way  
without the written permission of Seller. Buyer (at its own expense) shall indemnify and  
hold harmless Seller and defend or settle any action brought against Seller to the extent  
that it is based on a claim that any Product made to Buyer specifications infringed  
intellectual property rights of another party.  
2. Property; Confidentiality: Notwithstanding any charges to Buyer for engineering or  
tooling, all engineering and tooling shall remain the exclusive property of Seller. All  
information and materials supplied by Seller to Buyer relating to the Products are  
confidential and proprietary, and Buyer shall limit distribution thereof to its trusted  
employees and strictly prevent disclosure to any third party.  
3. Performance Data: Performance data is provided as a guide in determining suitability  
and does not constitute a warranty. It may represent the result of Seller's test conditions,  
and the users must correlate it to actual application requirements.  
4. Change In Specifications: Product specifications and descriptions may be changed at  
any time based on improvements or other reasons. It is Seller’s practice to change part  
numbers when published ratings or features are changed, or when significant  
engineering changes are made. However, some specifications of the Product may be  
changed without any notice.  
8. Financial: If the financial position of Buyer at any time becomes unsatisfactory to Seller,  
Seller reserves the right to stop shipments or require satisfactory security or payment in  
advance. If Buyer fails to make payment or otherwise comply with these Terms or any  
related agreement, Seller may (without liability and in addition to other remedies) cancel  
any unshipped portion of Products sold hereunder and stop any Products in transit until  
Buyer pays all amounts, including amounts payable hereunder, whether or not then due,  
which are owing to it by Buyer. Buyer shall in any event remain liable for all unpaid  
accounts.  
9. Cancellation; Etc: Orders are not subject to rescheduling or cancellation unless Buyer  
indemnifies Seller fully against all costs or expenses arising in connection therewith.  
10. Force Majeure: Seller shall not be liable for any delay or failure in delivery resulting from  
causes beyond its control, including earthquakes, fires, floods, strikes or other labor  
disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots,  
delay in or lack of transportation or the requirements of any government authority.  
11. Shipping; Delivery: Unless otherwise expressly agreed in writing by Seller:  
(a) All sales and shipments of Products shall be FOB shipping point (unless otherwise  
stated in writing by Seller), at which point title to and all risk of loss of the Products  
shall pass from Seller to Buyer, provided that Seller shall retain a security interest in  
the Products until the full purchase price is paid by Buyer;  
5. Errors And Omissions: The information on Seller’s website or in other documentation  
has been carefully checked and is believed to be accurate; however, no responsibility is  
assumed for clerical, typographical or proofreading errors or omissions.  
6. Export Controls: Buyer shall comply with all applicable laws, regulations and licenses  
regarding (a) export of the Products or information provided by Seller; (b) sale of  
Products to forbidden or other proscribed persons or organizations; (c) disclosure to non-  
citizens of regulated technology or information.  
(b) Delivery and shipping dates are estimates only; and  
(c) Seller will package Products as it deems proper for protection against normal  
handling and extra charges apply to special conditions.  
12. Claims: Any claim by Buyer against Seller for shortage or damage to the Products  
occurring before delivery to the carrier or any claim related to pricing or other charges  
must be presented in detail in writing to Seller within 30 days of receipt of shipment.  
III. PRECAUTIONS  
VI. MISCELLANEOUS  
1. Suitability: IT IS THE BUYER’S SOLE RESPOINSIBILITY TO ENSURE THAT ANY  
OMRON PRODUCT IS FIT AND SUFFICIENT FOR USE IN A MOTORIZED VEHICLE  
APPLICATION. BUYER SHALL BE SOLELY RESPONSIBLE FOR DETERMINING  
APPROPRIATENESS OF THE PARTICULAR PRODUCT WITH RESPECT TO THE  
BUYER’S APPLICATION INCLUDING (A) ELECTRICAL OR ELECTRONIC  
COMPONENTS, (B) CIRCUITS, (C) SYSTEM ASSEMBLIES, (D) END PRODUCT, (E)  
SYSTEM, (F) MATERIALS OR SUBSTANCES OR (G) OPERATING ENVIRONMENT.  
Buyer acknowledges that it alone has determined that the Products will meet their  
requirements of the intended use in all cases. Buyer must know and observe all  
prohibitions of use applicable to the Product/s.  
1. Waiver: No failure or delay by Seller in exercising any right and no course of dealing  
between Buyer and Seller shall operate as a waiver of rights by Seller.  
2. Assignment: Buyer may not assign its rights hereunder without Seller's written consent.  
3. Law: These Terms are governed by Illinois law (without regard to conflict of laws).  
Federal and state courts in Cook County, Illinois have exclusive jurisdiction for any  
dispute hereunder.  
4. Amendment: These Terms constitute the entire agreement between Buyer and Seller  
relating to the Products, and no provision may be changed or waived unless in writing  
signed by the parties.  
5. Severability: If any provision hereof is rendered ineffective or invalid, such provision shall  
not invalidate any other provision.  
2. Use with Attention: The followings are some examples of applications for which  
particular attention must be given. This is not intended to be an exhaustive list of all  
possible use of any Product, nor to imply that any use listed may be suitable for any  
Product:  
(a) Outdoor use, use involving potential chemical contamination or electrical  
interference.  
General Purpose Relay G7L  
Certain Precautions on Specifications and Use  
1. Suitability for Use. Seller shall not be responsible for conformity with any stan- 2. Programmable Products. Seller shall not be responsible for the user's pro-  
dards, codes or regulations which apply to the combination of the Product in  
gramming of a programmable product, or any consequence thereof.  
Buyer's application or use of the Product. At Buyer's request, Seller will pro- 3. Performance Data. Performance data given in this publication is provided as  
vide applicable third party certification documents identifying ratings and limi-  
tations of use which apply to the Product. This information by itself is not  
sufficient for a complete determination of the suitability of the Product in com-  
bination with the end product, machine, system, or other application or use.  
a guide for the user in determining suitability and does not constitute a war-  
ranty. It may represent the result of Seller's test conditions, and the users must  
correlate it to actual application requirements. Actual performance is subject to  
Seller's Warranty and Limitations of Liability.  
Buyer shall be solely responsible for determining appropriateness of the par- 4. Change in Specifications. Product specifications and accessories may be  
ticular Product with respect to Buyer's application, product or system. Buyer  
shall take application responsibility in all cases but the following is a non-  
exhaustive list of applications for which particular attention must be given:  
(i) Outdoor use, uses involving potential chemical contamination or electrical  
interference, or conditions or uses not described in this document.  
(ii) Energy control systems, combustion systems, railroad systems, aviation  
systems, medical equipment, amusement machines, vehicles, safety  
equipment, and installations subject to separate industry or government  
regulations.  
(iii) Use in consumer products or any use in significant quantities.  
(iv) Systems, machines and equipment that could present a risk to life or  
property. Please know and observe all prohibitions of use applicable to this  
product.  
changed at any time based on improvements and other reasons. It is our prac-  
tice to change part numbers when published ratings or features are changed,  
or when significant construction changes are made. However, some specifica-  
tions of the Product may be changed without any notice. When in doubt, spe-  
cial part numbers may be assigned to fix or establish key specifications for  
your application. Please consult with your Seller representative at any time to  
confirm actual specifications of purchased Product.  
5. Errors and Omissions. The information in this publication has been carefully  
checked and is believed to be accurate; however, no responsibility is assumed  
for clerical, typographical or proofreading errors, or omissions.  
6. RoHS Compliance. Where indicated, our products currently comply, to the  
best of our knowledge as of the date of this publication, with the requirements  
of the European Union's Directive on the Restriction of certain Hazardous  
Substances ("RoHS"), although the requirements of RoHS do not take effect  
until July 2006. These requirements may be subject to change. Please consult  
our website for current information.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS  
RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM  
AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT  
THE OMRON PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE  
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website  
at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
06/09  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
General Purpose Relay G7L  

相关型号:

G7L-2A-TUB-CB-AC200/240

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-TUB-CB-AC24

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-TUB-CB-AC50

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-TUB-CB-AC6

Power/Signal Relay, DPST, Momentary, 2500mW (Coil), AC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB-CB-DC100

Power/Signal Relay, DPST, Momentary, 0.019A (Coil), 100VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB-CB-DC12

Power/Signal Relay, DPST, Momentary, 0.16A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB-CB-DC24

Power/Signal Relay, DPST, Momentary, 0.079A (Coil), 24VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB-CB-DC48

Power/Signal Relay, DPST, Momentary, 0.039A (Coil), 48VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB-CB-DC6

Power/Signal Relay, DPST, Momentary, 0.317A (Coil), 6VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB12VAC

Power/Signal Relay, DPST, Momentary, 1700mW (Coil), AC Input, AC Output, Panel Mount
OMRON

G7L-2A-TUB12VDC

Power/Signal Relay, DPST, Momentary, 0.158A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON

G7L-2A-TUB200/240VAC

Power/Signal Relay, DPST, Momentary, 2448mW (Coil), AC Input, AC Output, Panel Mount
OMRON