G7L-1A-TUBJ-CB-DC12 [OMRON]
Power/Signal Relay, SPST, Momentary, 0.16A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,;型号: | G7L-1A-TUBJ-CB-DC12 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPST, Momentary, 0.16A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount, 继电器 |
文件: | 总14页 (文件大小:390K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
General Purpose Relay
G7L
• Ideally suited for high-inrush fluid pump controls: pool/spa, water
processing, emergency, chemical industry, etc.
• High-capacity, high-withstand voltage relay with no contact chatter-
ing for momentary voltage drops up to 50% of rated voltage.
• UL Class B construction standard.
• Wide-range AC-activated coil that handles 100 to 120 VAC at either
50 or 60 Hz.
• Miniature hinge for maximum switching capacity, particularly for in-
ductive loads.
• Flame resistant materials (UL94V-0-qualifying) used for
all insulation material.
• Quick-connect, screw, and PCB terminals available.
• Standard models are UL, CSA, and TUV approved;
VDE/IEC 950 versions are now available. Meet pollution degree 3,
Material Group II & III.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).
Type
Contact form
Model
Quick-connect terminal
G7L-1A-T-CB
G7L-2A-T-CB
G7L-1A-TJ-CB
G7L-2A-TJ-CB
G7L-1A-TUB-CB
G7L-2A-TUB-CB
G7L-1A-TUBJ-CB
G7L-2A-TUBJ-CB
—
Screw terminal
PCB terminal
E bracket (see note 1)
SPST-NO
G7L-1A-B-CB
—
—
—
—
—
—
—
—
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
SPST-NO
DPST-NO
G7L-2A-B-CB
G7L-1A-BJ-CB
G7L-2A-BJ-CB
G7L-1A-BUB-CB
G7L-2A-BUB-CB
G7L-1A-BUBJ-CB
G7L-2A-BUBJ-CB
—
E bracket (see note 1)
(with test button)
Upper bracket
Upper bracket
(with test button)
PCB mounting
G7L-1A-P-CB
G7L-2A-P-CB
—
—
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and part numbers.
2. For VDE approved versions, please consult OMRON.
3. CE marking is provided only on non-PCB terminal versions.
General Purpose Relay G7L
329
■ Model Number Legend
G7L- ❏ ❏ - ❏ ❏ ❏ ❏
1 2 3 4 5
6
1. Contact form
1A:SPST-NO
3. Mounting construction
No symbol:E bracket type
UB:Upper bracket type
5. 80: VDE approved version
(includes UL, CSA and TÜV)
2A:DPST-NO
6. CB: Class B insulation
7. Rated coil voltage
2. Terminal shape
4. Special functions
No symbol:Without test button
J:With test button
T:Quick-connect terminals
P:PCB terminals
B:Screw terminals
■ Accessories
Quick-connect Terminals
Description
Model
Model
Contact form
SPST-NO
G7L-1A-TJ
DPST-NO
G7L-2A-TJ
E-brackets
Track mounting adaptor
Front connecting socket
G7L-1A-T
G7L-2A-T
R99-07G5D
P7LF-D
P7LF-06
Note: A socket terminal cover is supplied with the P7LF-06 socket and does not attach directly to the G7L relays. It cannot be purchased separately.
Screw Terminals
Description
Model
Model
Contact form
SPST-NO
G7L-1A-BJ
DPST-NO
G7L-2A-BJ
E-brackets
G7L-1A-B
G7L-2A-B
R99-07G5D
Track mounting adaptor
Terminal Cover
P7LF-D
P7LF-C
Note: The P7LF-C terminal cover attaches directly to the G7L-B style relays. It is sold separately.
Specifications
■ Contact Data
Load
G7L-1A-T, G7L-1A-B
G7L-2A-T, G7L-2A-B
Resistive load Inductive load
(cosφ = 1) (cosφ = 0.4)
G7L-1A-P, G7L-2A-P
Resistive load
Inductive load
(cosφ = 0.4)
25 A, 220 VAC
Resistive load
(cosφ = 1)
Inductive load
(cosφ = 0.4)
(cosφ = 1)
30 A, 220 VAC
AgSnIn
Rated load
Contact material
Carry current
20 A, 220 VAC
30 A
25 A
25 A
20 A
Max. operating voltage 250 VAC
Max. operating current 30 A
Max. switching capacity 6,600 VA
20 A
5,500 VA
4,400 VA
Min. permissible load
100 mA, 5 VDC (please inquire for lower minimum rating)
Note: P level: λ60 = 0.1 x 10-6 operation.
■ Coil Internal Circuit
DC operating coil
AC operating coil
330
General Purpose Relay G7L
■ Coil Data
AC
Rated voltage
(V)
Rated current
(mA)
Resistance
Must operate
75% max.
Must release
% of rated voltage
15% min.
Max. voltage
110% max.
Power
(Ω)
consumption
6
283
142
18.90
Approx.1.70
to 2.50 VA
12
75
24
71
303
50
34
1,310
5,260
21,000
100/120
200/240
17.00/20.40
8.50/10.20
75 volts
18 volts
36 volts
132 volts
264 volts
150 volts
DC
Rated voltage
(V)
Rated current
(mA)
Resistance
(Ω)
Must operate
75% max.
Must release
% of rated voltage
15% min.
Max. voltage
110% max.
Power
consumption
6
317
158
79
18.90
75
Approx.1.90 W
12
24
48
100
303
40
1,220
5,260
19
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for AC rated cur-
rent and 15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).
■ Characteristics
Contact resistance
50 mΩ max.
Operate time
30 ms max.
Release time
30 ms max.
Max. operating
frequency
Mechanical
Electrical
1,800 operations/hour
1,800 operations/hour (under rated load)
Insulation resistance
Dielectric strength
1,000 MΩ min. (at 500 VDC)
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)
Between coil and contact: 10,000 V min./12,000 V typ. (impulse wave used: 1.20 x 50 μs)
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Impulse withstand voltage
Vibration
Mechanical
durability
Malfunction
durability
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
1,000 m/s2 (approx. 100 G)
Shock
Mechanical
durability
1,000 m/s2 (approx.10 G)
Malfunction
durability
Life expectancy
Mechanical
Electrical
1,000,000 operations min. (at 1,800 operations/hour)
100,000 operations min. (at 1,800 operations/hour under rated load 250,000 ops typical)
-25° to 60°C (-13° to 140°F)
Ambient temperature
Humidity
35% to 85% RH
Weight
Quick-connect terminal type: approx. 90 g (3.17 oz)
PCB terminal type: approx. 100 g (3.52 oz)
Screw terminal type: approx. 120 g (4.23 oz)
Note: Data shown are of initial value.
General Purpose Relay G7L
331
■ Characteristic Data
Maximum switching capacity
Electrical service life
Switching current (A)
Switching voltage (V)
Dimensions
Unit: mm (inch)
■ Relays
G7L-1A-T
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-T
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
* E bracket must be ordered separately.
332
General Purpose Relay G7L
G7L-1A-TJ
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TJ
(E Bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-TUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
*E bracket must be ordered separately.
General Purpose Relay G7L
333
Unit: mm (inch)
G7L-1A-TUBJ
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-TUBJ
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-B
(E bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-B
(E bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
* E bracket must be ordered separately.
334
General Purpose Relay G7L
G7L-1A-BJ
(E bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-BJ
(E bracket Attached)*
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-1A-BUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-BUB
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
* E bracket must be ordered separately.
General Purpose Relay G7L
335
Unit: mm (inch)
G7L-1A-BUBJ
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-BUBJ
Mounting holes
(Bottom view)
Terminal arrangement/
Internal connections
(Top view)
G7L-1A-P
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
G7L-2A-P
Terminal arrangement/
Internal connections
(Top view)
Mounting holes
(Bottom view)
336
General Purpose Relay G7L
■ Accessories
E bracket
R99-07G5D
Mounting holes
(Bottom view)
Adaptor
P7LF-D
Mounting holes
(Bottom view)
Front connecting socket
P7LF-06
Mounting holes
(Bottom view)
Note: 1. To protect against electric shock, a socket terminal cover is supplied with the P7LF-06 socket.
2. The P7LF-06 is panel or track mountable.
General Purpose Relay G7L
337
Unit: mm (inch)
Cover
P7LF-C
Note: P7LF-C cover attaches directly to G7L-B style relays. To protect against electric shock, use the P7LF-C on G7L-B terminals.
Mounting track
PFP-100N, PFP-50N
(Conforming to EN 50022)
PFP-100N2
(Conforming to EN 50022)
16
7.3 0.15
35 0.3
4.5
4.5
27
35 0.3
29.2
1.5
24
27 0.15
1
15 25
25
25
25 15
15 25
25
25
25
*
1
15 (5)
10
10
10
10
1000
4
1000 (500)*
* The figure in parenthesis is for PFP-50N.
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.
2. L = Length
PFP-100N L = 1 m (39.00 in)
PFP-50N
L = 50 cm (19.60 in)
PFP-100N2 L = 1 m (39.00 in)
End plate
PFP-M
Spacer
PFP-S
338
General Purpose Relay G7L
■ Approvals
UL Recognized (File No. E41643) / CSA Certified (File No. LR35535) - - Ambient Temp. = 40°C
Type
G7L-1A-T-CB
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
G7L-1A-P-CB
Contact form
Terminal type
Contact ratings
30 A, 277 VAC, General Use, 100,000 ops
1.5 kW, 120 VAC, Tungsten, 6,000 ops
1.5 HP, 120 VAC, 6,000 ops
SPST-NO
Quick-connect
3 HP, 277 VAC, 6,000 ops
20 FLA/120 LRA, 120 VAC, 30,000 ops
17 FLA/102 LRA, 265 VAC, 30,000 ops
TV-10, 120 VAC, 25,000 ops
Screw
PCB
G7L-2A-T-CB
DPST-NO
Quick-connect
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
G7L-2A-P-CB
Screw
PCB
Note: Contact Omron for actual ratings marked on G7L relays
TÜV (File No. R9251551)
Type
Contact form
Coil ratings
Terminal type
Contact ratings
G7L-1A-T-CB
G7L-1A-TJ-CB
G7L-1A-TUB-CB
G7L-1A-TUBJ-CB
G7L-1A-B-CB
G7L-1A-BJ-CB
G7L-1A-BUB-CB
G7L-1A-BUBJ-CB
G7L-1A-P-CB
SPST-NO
6, 12, 24, 48,
100, 110, 200,
220 VDC
Quick-connect
25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
12, 24, 50,
100/120, 200/240
VAC
Screw
30 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
30 A, 240 VAC, (cosφ = 0.4)
PCB
20 A, 240 VAC, (cosφ = 1)
20 A, 240 VAC, (cosφ = 0.4)
25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
G7L-2A-T-CB
DPST-NO
Quick-connect
G7L-2A-TJ-CB
G7L-2A-TUB-CB
G7L-2A-TUBJ-CB
G7L-2A-B-CB
G7L-2A-BJ-CB
G7L-2A-BUB-CB
G7L-2A-BUBJ-CB
G7L-2A-P-CB
Screw
PCB
25 A, 240 VAC, (cosφ = 1)
25 A, 240 VAC, (cosφ = 0.4)
20 A, 240 VAC, (cosφ = 1)
20 A, 240 VAC, (cosφ = 0.4)
VDE recognized type (Licence no. 1530 UG)
Note: 1. Please consult OMRON for details of VDE approvals.
2. The G7L relay conforms to the following standards:
Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83
DIN VDE 0435 Teil 201 A1/05. 90
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81
DIN EN 60 950/VDE 0805/11. 93
EMC:
prEN 50082-2, EN 55022
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
4. In the interest of product improvement, specifications are subject to change.
5. Suffix T130 rated at 130°C
6. Pollution degree 3, Material Group II & III.
7. CE marking is provide only on non-PCB terminal versions.
General Purpose Relay G7L
339
Precautions
■ Handling
■ Operating Coil
• To preserve initial performance, do not drop or otherwise subject
• As a rule, either a battery or a DC power supply with a maximum
5% ripple is used for the operating voltage for DC relays. Before
using a rectified AC supply, confirm that the ripple is not greater
than 5%. Ripple greater than this can lead to variations in the oper-
ating and reset voltages.
the power relay to shock.
• The case is not designed to be removed during normal handling
and operation. Doing so may affect performance.
• Use the power relay in a dry environment free from excessive dust,
SO2, H2S, or organic gas.
As excessive ripple can generate beats, the insertion of a
smoothing capacitor is recommended as shown below.
• Do not allow a voltage greater than the maximum allowable coil
voltage to be applied continuously.
• Do not use the power relay outside of specified voltages and cur-
rents.
• Do not allow the ambient operating temperature to exceed the
specified limit.
■ Installation
• Although there are not specific limits on the installation site, it
should be as dry and dust-free as possible.
• PCB terminal-equipped relays weigh approximately 100 g. Be sure
that the PCB is strong enough to support them. We recommend
dual-side through-hole PCBs to reduce solder cracking from heat
stress.
• Quick-connect terminals can be connected to fast on receptacle
#250 and positive-lock connectors.
• Allow suitable slack on leads when wiring, and do not subject the
terminals to excessive force.
• When driving a transistor, check the leakage current and connect a
bleeder resistor if necessary.
■ Cleaning PCB Terminals
• PCB terminals have semi-sealed construction which prevents flux
from entering the relay base. It is recommended that the user
should apply a tape seal over the vent hole prior to wave soldering
or cleaning. The tape should then be removed after processing.
• Momentary voltage drops on coil input voltage should not exceed
one second duration after contact mating with no shock or vibra-
tion.
■ Applications
• Compressors for package air conditioners and heater switching
controllers
• Switching controllers for power tools or motors
• Power controllers for water heaters
• Power controllers for dryers
• Lamp control, motor drivers, and power supply switching in copy
machines, facsimiles, and other OA equipment
• Lighting controllers
• Power controllers for packers or food processing equipment
• Magnetron control in microwaves
340
General Purpose Relay G7L
MEMO
General Purpose Relay G7L
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
General Purpose Relay G7L
相关型号:
G7L-1A-TUBJ-CB-DC24
Power/Signal Relay, SPST, Momentary, 0.079A (Coil), 24VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON
G7L-1A-TUBJ-CB-DC48
Power/Signal Relay, SPST, Momentary, 0.039A (Coil), 48VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON
G7L-1A-TUBJ-CB-DC6
Power/Signal Relay, SPST, Momentary, 0.317A (Coil), 6VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON
G7L-1A-TUBJ100/120VAC
Power/Signal Relay, SPST, Momentary, 2400mW (Coil), AC Input, AC Output, Panel Mount
OMRON
G7L-1A-TUBJ12VAC
Power/Signal Relay, SPST, Momentary, 1700mW (Coil), AC Input, AC Output, Panel Mount
OMRON
G7L-1A-TUBJ12VDC
Power/Signal Relay, SPST, Momentary, 0.158A (Coil), 12VDC (Coil), 1900mW (Coil), DC Input, AC Output, Panel Mount,
OMRON
G7L-1A-TUBJ200/240VAC
Power/Signal Relay, SPST, Momentary, 2448mW (Coil), AC Input, AC Output, Panel Mount
OMRON
©2020 ICPDF网 联系我们和版权申明