CSM_G7Z_DS_E_5_1  
Multi-pole Power Relay for Contactor Current Range  
Capable of Carrying and Switching 40 A at 440 VAC  
• One pole, 40 A can be carried and switched.  
• The maximum load capacity of 160 A when using 4-pole parallel connections.  
• All materials used are compliant with the RoHS Directive  
• EN 60947-4-1 certification for mirror contact mechanisms has been obtained by  
using a combination of the relay and auxiliary contact blocks.  
• A design with a small number of openings makes it difficult for dust or foreign  
matter to enter.  
• Ideal for supply power to industrial inverters, servo drivers, and other devices,  
and switching power to motors and other equipment.  
• Conforms to European PV standard (VDE0126).  
Be sure to read the “Safety Precautions” on page 6 and the  
“Precautions for All Relays with Forcibly Guided Contacts”.  
Model Number Structure  
Model Number Legend  
Relay with Auxiliary Contact Block  
Relay  
G7Z-@  
G7Z-@-@@  
1
1
2 3  
1. Relay Contact Configuration  
4A: 4PST-NO  
1. Contact Configuration  
4A:  
4PST-NO  
3A1B: 3PST-NO/SPST-NC  
2A2B: DPST-NO/DPST-NC  
3A1B: 3PST-NO/SPST-NC  
2A2B: DPST-NO/DPST-NC  
2. Contact Configuration of Auxiliary Contacts  
20:  
11:  
02:  
DPST-NO  
SPST-NO/SPST-NC  
DPST-NC  
Auxiliary Contact Block  
G73Z-@@  
3. Contact Mechanism of Auxiliary Contacts  
Z: Bifurcated crossbar contact  
1 2  
1. Contact Configuration of Auxiliary Contacts  
20: DPST-NO  
11: SPST-NO/SPST-NC  
02: DPST-NC  
2. Contact Mechanism of Auxiliary Contacts  
Z: Bifurcated crossbar contact  
Ordering Information  
Relay with Auxiliary Contact Block  
Relay with Auxiliary Contact Block (for Screw Terminals)  
Structure  
Contact configuration  
Rated Voltage  
Model  
Auxiliary Contact  
Relay  
Classification  
Block  
DPST-NO  
G7Z-4A-20Z  
4PST-NO  
SPST-NO/SPST-NC  
DPST-NC  
G7Z-4A-11Z  
G7Z-4A-02Z  
DPST-NO  
SPST-NO/SPST-NC  
DPST-NC  
G7Z-3A1B-20Z  
G7Z-3A1B-11Z  
G7Z-3A1B-02Z  
G7Z-2A2B-20Z  
G7Z-2A2B-11Z  
G7Z-2A2B-02Z  
Relay with Auxiliary  
Contact Block  
4 poles +  
2 poles  
3PST-NO/SPST-NC  
12, 24 VDC  
DPST-NO  
DPST-NO/DPST-NC SPST-NO/SPST-NC  
DPST-NC  
Note: 1. Relay contact terminals are M5, and the coil terminals are M3.5.  
2. Auxiliary contact block terminals are M3.5.  
3. When placing an order, specify the model number and rated supply voltage (12 VDC or 24 VDC).  
1
G7Z  
Relay  
Structure  
4 poles  
Contact configuration  
Rated Voltage  
Model  
G7Z-4A  
Classification  
Relay  
4PST-NO  
3PST-NO/SPST-NC  
DPST-NO/DPST-NC  
12, 24 VDC  
G7Z-3A1B  
G7Z-2A2B  
Note: 1. Relay contact terminals are M5, and the coil terminals are M3.5.  
2. When placing an order, specify the model number and rated supply voltage (12 VDC or 24 VDC).  
Accessories (Order Separately)  
Auxiliary Contact Block  
Classification  
Structure Contact Configuration  
DPST-NO  
Model  
G73Z-20Z  
G73Z-11Z  
G73Z-02Z  
Auxiliary Contact Block 2 poles  
SPST-NO/SPST-NC  
DPST-NC  
Specifications  
Ratings  
Coil  
Item  
Must operate Must release  
voltage voltage  
Maximum  
voltage  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power  
consumption  
(W)  
Rated voltage  
Percentage of rated voltage  
12 VDC  
24 VDC  
308  
154  
39  
75% max. 10% min. 110%  
Approx. 3.7  
156  
Note: 1. Rated current and coil resistance were measured at a coil temperature of 23°C with coil resistance of 15%.  
2. Operating characteristics were measured at a coil temperature of 23°C.  
3. The maximum allowable voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was  
measured at an ambient temperature of 23°C.  
There is, however, no continuous allowance.  
Contacts  
Relay  
Auxiliary Contact Block  
G7Z-4A-@Z, G7Z-3A1B-@Z,  
G7Z-2A2B-@Z  
Model  
G73Z-20Z, G73Z-11Z, G73Z-02Z  
Model  
Load  
Inductive  
Resistive  
Resistive  
load  
Inductive  
Resistive  
Load  
load cosφ = load L/R = 1  
Resistive  
load  
load cosφ = load L/R = 1  
Item  
0.3  
ms  
Item  
0.3  
ms  
Contact structure  
Contact material  
Double break  
Au clad + Ag  
Contact structure  
Contact material  
Double break  
Ag alloy  
1 A at  
440 VAC  
0.5 A at  
440 VAC  
0.5 A at  
110 VDC  
Rated load  
40 A at  
440 VAC  
22 A at  
440 VAC  
5 A at  
110 VDC  
NO  
NC  
Rated carry current  
1 A  
Rated load  
25 A at  
440 VAC  
10 A at  
440 VAC  
5 A at  
110 VDC  
Maximum contact voltage  
Maximum contact current  
Maximum switching capacity  
480 VAC  
125 VDC  
55 W  
1 A  
0.5 A  
NO  
NC  
40 A  
25 A  
Rated carry current  
440 VA  
220 VA  
Failure rate P value  
(reference value)  
1 mA at 5 VDC  
Maximum contact voltage  
480 VAC  
125 VDC  
5 A  
NO  
40 A  
25 A  
22 A  
10 A  
Maximum contact  
current  
NC  
NO  
NC  
5 A  
17,600 VA  
11,000 VA  
9,680 VA  
4,400 VA  
550 W  
550 W  
Maximum switching  
capacity  
Failure rate P value  
(reference value)  
2 A at 24 VDC  
Note: The ratings for the auxiliary contact block mounted on the G7Z  
are the same as those for the G73Z auxiliary contact block.  
2
G7Z  
Characteristics  
Classification  
Relay *5  
Auxiliary contact block  
G73Z-20Z, G73Z-11Z, G73Z-02Z  
100 mΩ max.  
Item  
Model G7Z-4A-@Z, G7Z-3A1B-@Z, G7Z-2A2B-@Z  
400 mΩ max.  
Contact resistance *1  
Operating time *2  
Release time *2  
50 ms max.  
50 ms max.  
Mechanical  
1,800 operations/h  
Maximum operating  
frequency  
Rated load  
1,200 operations/h  
Insulation resistance *3  
1,000 MΩ min.  
Between coil and contacts  
4,000 VAC, 50/60 Hz for 1 min  
---  
---  
Dielectric strength  
Between contacts of different polarity 4,000 VAC, 50/60 Hz for 1 min  
Between contacts of the same polarity 2,000 VAC, 50/60 Hz for 1 min  
Between coil and contacts  
10 kV, 1.2 × 50 µs  
Impulse withstand  
voltage  
Between contacts of different polarity 10 kV, 1.2 × 50 µs  
Between contacts of the same polarity 4.5 kV, 1.2 × 50 µs  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)  
Vibration resistance  
Shock resistance  
NO: 10 to 55 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)  
NC: 10 to 32 to 10 Hz, 0.5-mm single amplitude (1.0-mm double amplitude)  
Screw mounting: 700 m/s2, DIN Track mounting: 500 m/s2  
NO: 100 m/s2  
NC: 25 m/s2  
1,000,000 operations min. (at 1,800 operations/h, contact no load)  
AC resistive load: 80,000 operations  
AC inductive load: 80,000 operations  
DC resistive load: 100,000 operations  
(at 1,200 operations/h, rated load)  
Durability  
Electrical *4  
Failure rate (P level) (reference value) *6  
Ambient operating temperature  
Ambient operating humidity  
Weight  
2 A at 24 VDC  
1 mA at 5 VDC  
Approx. 18 g  
25 to 60°C (with no icing or condensation)  
5% to 85%  
Approx. 330 g  
Note: The above values are initial values.  
*1. The contact resistance for the Relay (G7Z) was measured with 1 A at 5 VDC using the voltage drop method.  
The contact resistance for the auxiliary contact block (G73Z) was measured with 0.1 A at 5 VDC using the voltage drop method.  
*2. The operate time was measured with the rated voltage imposed with any contact bounce ignored at the ambient temperature of 23°C.  
*3. The insulation resistance was measured with a 1,000-VDC megohmmeter applied to the same places as those used for checking the dielectric  
strength.  
*4. The electrical endurance was measured at an ambient temperature of 23°C.  
*5. The specifications for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.  
*6. The failure rate is based on an operating frequency of 1,800 operations/h.  
Approved Standards  
UL Standard: UL508, UL840 (File No. E41643)  
CSA Standard: CSA Certification by  
: CSA C22.2 No. 14  
CCC Certification (File No.2009010304361493)  
GB14048.4  
EN Standard/TÜV Certification: EN 60947-4-1  
(Certification No. R50079155)  
Number of  
test  
operations  
Coil  
ratings  
Model  
Contact ratings  
40 A, 480 VAC, 60 Hz  
(Resistive)  
80,000  
100,000  
100,000  
---  
5 A, 120 VDC (Resistive)  
NO  
contact  
22 A, 480 VAC, 60 Hz  
(General Use)  
Model  
Coil ratings  
Contact ratings  
D300* (1-A current applied)  
AC-1: 40 A, 440 V, 50/60 Hz  
AC-3: 16 A, 440 V, 50/60 Hz  
DC-1: 5 A, 110 V  
*AC-15: 0.5 A, 440 V, 50/60 Hz  
*DC-13: 0.5 A, 110 V  
G7Z  
12, 24 VDC  
25 A, 480 VAC, 60 Hz  
(Resistive)  
NO  
contact  
5 A, 120 VDC (Resistive)  
10 A, 480 VAC, 60 Hz  
(General Use)  
100,000  
---  
NC  
contact  
G7Z  
12, 24 VDC  
AC-1: 25 A, 440 V, 50/60 Hz  
DC-1: 5 A, 110 V  
*AC-15: 0.5 A, 440 V, 50/60 Hz  
*DC-13: 0.5 A, 110 V  
NC  
contact  
D300* (1-A current applied)  
* Auxiliary contact ratings  
NO  
contact  
Model  
Contact ratings  
AC-15: 0.5 A, 440 V , 50/60 Hz  
DC-13: 0.5 A, 110 V  
NO contact  
G73Z  
G73Z  
---  
D300 (1-A current applied)  
NC  
contact  
NC contact  
* Auxiliary contact ratings  
< Reference > Information  
UL 508:  
UL 840:  
Industrial control devices  
Insulation coordination including clearance and  
creepage distance for electrical devices  
CSA C22.2 No. 14: Industrial control devices  
EN 60947-4-1: Contactors  
3
G7Z  
Dimensions  
(Unit: mm)  
Dimensions  
Relay (12 VDC, 24 VDC) with Auxiliary Contact Block  
4 Poles  
Mounting Hole Dimensions  
Two, M4  
0.2  
45  
39  
15  
Four, M3.5  
47  
Eight, M5  
92  
84  
75.7  
Two, M3.5  
70.7  
60  
51.5  
62  
Note: The dimensions are typical values.  
Relay (12 VDC, 24 VDC)  
4 Poles  
Mounting Hole Dimensions  
Two, M4  
62  
0.2  
45 23  
39  
6
11  
14.5 14.5 14.5  
9.25  
12.5  
8-M5  
2-M3.5  
70.7  
60  
51.5  
20.5  
Note: The dimensions are typical values.  
Contact Block  
Auxiliary DIN Track Mounting Height  
(when using the PFP-100N or PFP-50N mounting rail)  
15  
13  
Four, M3.5  
47  
32.2  
24.2  
30  
15.7  
96.3  
88.3  
75.0  
64.3  
11  
15  
Note: The dimensions are typical values.  
Note: The dimensions are typical values.  
4
G7Z  
Terminal Arrangement/Internal Connections  
Relay with Auxiliary Contact Block  
G7Z-4A-20Z  
G7Z-4A-11Z  
G7Z-4A-02Z  
51  
A1  
52 61  
3
62  
7
53  
A1  
54 63  
3
64  
7
53  
A1  
54 61  
3
62  
7
1
5
1
5
1
5
A2  
2
4
6
8
A2  
2
4
6
8
A2  
2
4
6
8
Note: The coil has no polarity.  
Note: The coil has no polarity.  
Note: The coil has no polarity.  
G7Z-3A1B-20Z  
G7Z-3A1B-11Z  
G7Z-3A1B-02Z  
53  
A1  
54 63  
3
64  
21  
53  
A1  
54 61  
3
62  
21  
51  
A1  
52 61  
3
62  
21  
1
5
1
5
1
5
A2  
2
4
6
22  
A2  
2
4
6
22  
A2  
2
4
6
22  
Note: The coil has no polarity.  
Note: The coil has no polarity.  
Note: The coil has no polarity.  
G7Z-2A2B-20Z  
G7Z-2A2B-11Z  
G7Z-2A2B-02Z  
53  
A1  
54 61  
3
62  
21  
51  
A1  
52 61  
3
62  
21  
53  
A1  
54 63  
3
64  
21  
1
11  
1
11  
1
11  
A2  
2
4
12  
22  
A2  
2
4
12  
22  
A2  
2
4
12  
22  
Note: The coil has no polarity.  
Note: The coil has no polarity.  
Note: The coil has no polarity.  
Auxiliary Contact Block  
G73Z-20Z  
G73Z-11Z  
G73Z-02Z  
53  
54 63  
64  
53  
54 61  
62  
51  
52 61  
62  
5
G7Z  
Safety Precautions  
Refer to the “Precautions for All Relays” and “Precautions for All Relays with Forcibly Guided Contacts”.  
The Relay can be mounted directly on a mounting rail (PFP) or a  
DIN Track (EN 50022-35 × 7.5, 15). The Relay cannot be mounted,  
however, to some reinforced rails (e.g., those produced by  
!WARNING  
Take measures to prevent contact with charged parts  
when using the Relay for high voltages.  
Kameda Denki or Toyogiken).  
Mount the Relay sideways when it is mounted on a rail.  
Use End Plates (PFP-M) on both sides of the Relay to make sure  
that it is properly secured.  
!CAUTION  
Up  
Do not touch the terminal section (charged parts) when  
power is being supplied.  
Always use the Relay with terminal covers mounted.  
Contact with charged parts may result in electric shock.  
Do not touch the Relay when power is being supplied or  
right after the power has been turned OFF.  
The hot surface may cause burn injury.  
DIN Track  
(35 mm)  
Provide at least 5 mm of space between the sides and top of the  
Relay and nearby grounded metal surfaces.  
Precautions for Correct Use  
Installation  
Mount the G7Z with the coil terminal at the top.  
5 mm min.  
Grounded metal surface  
Up  
Coil terminal  
5 mm min.  
5 mm min.  
Provide at least 30 mm of space between Relays when two or more  
Relays are mounted in a row.  
Do not use the Relay with the terminal screw surfaces facing down.  
30 mm min.  
The auxiliary contact block (G73Z) can be mounted on the Relay.  
Mounting and Removal  
Mounting  
Insert the tab on the auxiliary contact  
(1)  
Hook  
Terminal screw surface  
To mount the Relay, secure M4 screws in two locations.  
Use a screw-tightening torque of 1.2 to 1.3 N·m.  
block into the groove on the Relay and  
press down until the hook on the  
auxiliary contact block catches in the  
Tab  
(2)  
mounting hole on the Relay.  
39 mm  
Removing  
(1)  
Slide the auxiliary contact block, remove  
the auxiliary contact block tab from the  
groove on the Relay, and remove the  
auxiliary contact block hook from the  
Relay.  
Tab  
(2)  
Hook  
Be careful not to apply excessive force  
on the hook.  
6
G7Z  
Connecting  
Coil  
Use round or open-end (Y-type) crimp terminals and connect the  
terminals with the appropriate tightening torque. Refer to the  
terminal section space in the following figure for the crimp terminal  
dimensions.  
(Internal Connections of Coils)  
DC Coil  
A2  
A1  
Relay Contacts (Unit: mm)  
If a transistor drives the G7Z, check the leakage current and  
connect a bleeder resistor if necessary.  
14.5  
12.5  
The must operate voltage is the minimum value for the Relay  
armature to operate and the contacts to turn ON. Therefore,  
fundamentally apply the rated voltage to the coils, taking into  
consideration the increases in coil resistance caused by voltage  
fluctuation and coil temperature rise.  
11  
6
6
Counter-electromotive voltage generated by the coil when the coil  
is OFF may destroy semiconductor elements or cause  
malfunctions. Attach surge-absorbing diodes to both ends of the  
coil as a countermeasure. Particularly, when driving G7Z with  
semiconductor elements, always attach the surge-absorbing  
diodes.  
M5  
Relay Coil  
6.8  
4.3  
Note that the relay reset time will be extended, so always use after  
verifying implementation under actual usage conditions.  
Use surge-absorbing diodes with a minimum of 600 V reverse  
voltage resistance, and a forward current of approximately 1A.  
G7Z does not have coil polarity so attach surge-absorbing diodes  
so that the polarity is reverse to the applied voltage of the coil.  
M3.5  
Auxiliary Contact Block  
9.5  
6.8  
Mirror Contact Mechanism  
5.5  
5.5  
By combining a Relay with an auxiliary contact block, all NC contacts  
of the auxiliary contact block will satisfy an impulse withstand voltage  
of 2.5 kV or higher or maintain a gap of 0.5 mm or greater when the  
coil is de-energized even if at least one NO contact (main contact) of  
the Relay is welded.  
M3.5  
One crimp terminal can be used for the Relay contact section (M5  
screw). Two crimp terminals can be connected for the coil terminal  
and auxiliary contact block.  
Description of Mirror Contact Mechanism  
Recommended Crimp Terminals and Wire  
Crimp  
Impulse withstand voltage: 2.5 kV min. or  
contact separation (a + b): 0.5 mm min.  
Location  
Appropriate wire size  
Auxiliary contact block  
terminals  
a
b
5.5-5  
2.63 to 6.64 mm2 (AWG12, 10)  
6.64 to 10.52 mm2 (AWG8)  
Contact  
section  
8-5  
Coil  
section  
1.25-3.5  
0.5 to 1.65 mm2 (AWG20 to 16)  
Relay  
NC  
NC  
Use the following tightening torque when tightening screws. Loose  
screws may result in fire caused by abnormal heat generated when  
the power is being supplied.  
NO  
NO  
NO  
NO  
M5 screws:  
2.0 to 2.2 N·m  
M3.5 screws: 0.8 to 0.9 N·m  
Allow suitable slack on leads when wiring, and do not subject the  
terminals to excessive force.  
Contact welding  
Microloads  
The G7Z is used for switching power loads, such as current carry for  
device power supplies and heater loads. Use an auxiliary contact  
block (G73Z) if microloads are required for signal applications and  
operation status feedback.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2010.8  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2010 All Right Reserved.  
Mouser Electronics  
Authorized Distributor  
Click to View Pricing, Inventory, Delivery & Lifecycle Information:  
Omron:  
G73Z-11Z G7Z-2A2B-02Z DC12 G7Z-2A2B-02Z DC24 G7Z-2A2B-11Z DC12 G7Z-2A2B-20Z DC12 G7Z-2A2B-20Z  
DC24 G7Z-3A1B-02Z DC12 G7Z-3A1B-02Z DC24 G7Z-3A1B-11Z DC12 G7Z-3A1B-11Z DC24 G7Z-3A1B-20Z DC12  
G7Z-3A1B-20Z DC24 G7Z-4A-02Z DC12 G7Z-4A-02Z DC24 G7Z-4A-11Z DC12 G7Z-4A-11Z DC24 G7Z-4A-20Z  
DC12 G7Z-4A-20Z DC24 G7Z-2A2B-11Z DC24  

G73Z-20Z 相关器件

型号 制造商 描述 价格 文档
G747 ETC Desktop Cases 获取价格
G747A ETC Desktop Cases 获取价格
G748 ETC Desktop Cases 获取价格
G748A ETC Desktop Cases 获取价格
G749 ETC Desktop Cases 获取价格
G749A ETC Desktop Cases 获取价格
G74B IDEA T-1-3/4 Double Height, Right-Angle LED Assembly 获取价格
G75 TAYCHIPST Silicon Z–Diodes 获取价格
G75-010-05H-AGBA-H MITSUMI Interface Connectors for Cradle 获取价格
G750 ALLEN-BRADLEY MobileView Guard 获取价格

G73Z-20Z 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    6
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    9
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6