G6SK-2G-DC12 [OMRON]
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.017A (COIL), 12VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT;型号: | G6SK-2G-DC12 |
厂家: | OMRON ELECTRONICS LLC |
描述: | POWER/SIGNAL RELAY, DPDT, LATCHED, 0.017A (COIL), 12VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总12页 (文件大小:723K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
GLow6SigSnal Relay
Suface Mount DPDT Relay
• High dielectric withstand voltage of 2,000 VAC between coil
and contacts (standard type); 1,500 VAC between contacts
of different polarity.
• Meets FCC Part 68 and Telcordia 2.5 kV surge withstand.
• European version certified for EN60950/EN41003 Supple-
mentary Insulation at 250 V at Pollution Degree 2.
• Low power consumption of 140 mW (Non-latching)
• Available in through-hole and SMT terminals.
• Tape and reel or tube packaging.
• RoHS Compliant.
Ordering Information
■ Standard Version
.
Model
Contact form
DPDT
Non-latching
Terminal
Gull-wing
Single coil latching
Dual coil latching
Standard
G6S-2F
European Version*
G6S-2F-Y
G6S-2G-Y
G6S-2-Y
G6SU-2F
G6SU-2G
G6SU-2
G6SK-2F
G6SK-2G
G6SK-2
Inside “L”
G6S-2G
G6S-2
PCB through-hole
* Certified for EN60950/EN41003 Supplementary Insulation at 250 V (pollution degree 2)
Notes: 1. When ordering, add the rated coil voltage to the model number.
Example: G6S-2F DC12
Rated coil voltage
2. When ordering tape packing (surface mount models), add "-TR" to the model number.
Example: G6S-2F-TR DC12
Tape packing
"-TR" is not part of the relay model number. Therefore, it is not marked on the relay case.
3. Dual coil latching models are available with a High-sensitivity coil. (140 mW; 200 mW for DC24)
When ordering High-sensitivity dual coil latching models, add "-H” to the model number.
Example: G6SK-2G-H-TR DC5
High-sensitivity coil
Model Number Legend
G6S
-
-
-
DC
1
2 3
4
5
6
5. Packaging
None: Tube packaging
3. Terminal Shape
None: Through-hole
1. Relay Function
None: Non-latching
TR:
Tape and reel packaging
U:
K:
Single coil latching
Dual coil latching
F:
Gull-wing surface mount
Inside “L” surface mount
(Surface mount models)
G:
2. Contact Form
4. Approved Standards
6. Rated Coil Voltage
3, 4.5, 5, 12, 24 VDC
2: DPDT
None: UL/CSA
Y:
EN60950/EN41003
(Standard coil models - 5, 12, 24 VDC )
Low Signal Relay G6S
79
Specification
■ Contact Data
Load
Resistive load (cos φ = 1)
Rated load
0.5 A at 125 VAC
2 A at 30 VDC
Contact material
Max. carry current
Ag (Au clad)
2 A
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
250 VAC, 220 VDC
2 A
62.5 VA, 60 W
10 μA, 10 mVDC
Note: P level: λ60 = 0.1 x 10-6/operation
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary
depending on the operating environment. Always double-check relay suitability under actual operating conditions.
■ Coil Data
G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2)
Pick-up
voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Power consumption (mW)
3
4.5
5
12
24
46.7
64.3
145
178
1,028
2,880
75% max.
10% min.
200% max.@ 23°C Approx. 140
31.0
28.1
11.7
8.3
170% max.@ 23°C Approx. 200
G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2)
Coil Inductance (H)
(ref. value)
Armature OFF Armature ON
Set pick-up Reset pick-up
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Power
consumption
(mW)
Maximum volt-
age
voltage
voltage
% of rated voltage
3
4.5
5
12
24
33.3
90
203
250
1,440
3,840
0.108
0.27
0.36
2.12
5.80
0.069
0.14
0.18
1.14
3.79
75% max.
75% max.
180% max.
@ 23°C
Approx. 100
22.2
20.0
8.3
6.3
Approx. 150
G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2)
Coil Inductance (H)
(ref. value)
Set
pick-up
voltage
Reset
pick-up
voltage
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Power
consumption
(mW)
Maximum
voltage
Set
Armature Armature Armature Armature
OFF ON OFF ON
0.045 0.035 0.032 0.045
Reset
% of rated voltage
3
4.5
5
12
24
66.6
45
75% max. 75% max. 170% max. Approx. 200
@ 23°C
44.4
40
16.7
12.5
101
125
720
1,920
0.12
0.14
0.60
1.98
0.074
0.088
0.41
0.082
0.098
0.46
0.14
0.16
0.54
2.23
1.23
1.34
140% max. Approx. 300
@ 23°C
G6S - European Version, Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Pick-up
voltage
Dropout
voltage
% of rated voltage
Maximum
voltage
Power consumption (mW)
5
40.0
125
75% max.
10% min.
170% max.@ 23°C Approx. 200
12
24
16.7
9.6
720
2,504
Approx. 230
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. Pick-up voltage will vary with temperature.
4. The maximum voltage is the highest voltage that can be imposed on the relay coil.
80
Low Signal Relay G6S
■ Characteristics
Contact resistance (See note 1)
Operate (set) time (See note 2)
Release (reset) time (See note 2)
Bounce time
75 mΩ max.
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)
Approx. 0.5 ms
Max. operating frequency
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance (See note 3)
Dielectric strength
1,000 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole
500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK)
Surge withstand voltage Conforming to
Telcordia specs.
2,500 V (2 x 10 μS) between coil and contacts for G6S and G6SU
2,500 V (2 x 10 μS) between contacts of different poles
Conforming to
FCC Part 68
1,500 V (10 x 160 μS) between coil and contacts for G6SK
1,500 V (10 x 160 μS) between contacts of same pole
Vibration
Shock
Mechanical durability 10 to 55 Hz; 5 mm double amplitude
Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude
1,000 m/s2; approx. 100 G
750 m/s2; approx. 75 G
Mechanical durability
Malfunction durability
Ambient temperature
Ambient Humidity
Service life
-40 to +85°C with no icing; -40 to +70°C with no icing (G6SK, DC24 coil)
5% to 85% RH
Mechanical
Electrical
100,000,000 operations min. (at 36,000 operations/hour)
100,000 operations min. (2A@30VDC, resistive; 1,200 ops/hr.)
100,000 operations min. (0.5A@125VAC, resistive)
See “Characteristic Data”
Weight
Approx. 2g
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength (except between the set and reset coil).
4. Data shown are of initial value.
■ Characteristic Data
Service Life
1000
500
1000
500
1000
500
300
200
300
200
300
200
100
50
100
50
100
50
30
20
30
20
30
20
10
10
10
0
0.2
0.4
0.6
0.8
1.0
0
0.1
0.2
0.3
0.4
0.5
0
0.2
0.4
0.6
0.8
1.0
Service life (x106 operations)
Resistive load: 100 mA, 50 VDC
Ambient temperature: +85˚
Service life (x106 operations)
Service life (x106 operations)
Resistive load: 10 mA, 10 VDC
Ambient temperature: +85˚
Resistive load: 100 mA, 28 VDC
Ambient temperature: +85˚
Low Signal Relay G6S
81
Maximum Switching Capacity
Ambient Temperature vs.
Maximum Coil Voltage
Non-latching
Single Coil Latching
Dual Coil Latching
12 VDC max.
G6SU
AC resistive load
24 VDC
(G6S-Y, 12 VDC max.)
G6SK
12 VDC
max.
G6SK
24 VDC
24 VDC
(G6S-Y)
DC resistive load
Switching voltage (V)
Ambient temperature (°C)
Ambient temperature (°C)
Note: The maximum coil voltage refers to the maximum value in a varying range of
operating power voltage, not a continuous voltage.
Reference Data
Ambient Temperature vs. Switching Current
Non-latching
Single Coil Latching
Dual Coil Latching
G6SU
12 VDC max.
G6SU
12 VDC max.
24 VDC
G6SK
12 VDC max.
24 VDC
(G6S-Y)
24 VDC
G6SK
24 VDC
(G6S-Y, 12 VDC
max.)
Ambient temperature (°C)
Ambient temperature (°C)
Electrical Service Life
Dielectric Strength (Standard Version, Non-latching)
Detecting current: 1mA
50
40
50
500
300
200
40
100
30
20
30
20
30 VDC
70
50
30
125 VAC
10
0
10
0
10
0
0.4
0.8
1.2
1.6
2.0
1000
1500
2000
2500
3000
3500
1000
1500
2000
2500
3000
3500
Breakdown voltage (V)
Rated operating current (A)
Breakdown voltage (V)
Between coil and contacts
Between contacts of different poles
Between contacts of same pole.
82
Low Signal Relay G6S
Impulse Withstand Voltage (Standard Version, Non-latching)
(2 x 10 μs)
(10 x 160 μs)
(10 x 160 μs)
15
9
9
10
6
3
6
5
0
3
0
0
1500
2000
2500
3000
3500
4000
3500
4000
4500
5000
5500
6000
3500
4000
4500
5000
5500
6000
Breakdown voltage (V)
Breakdown voltage (V)
Breakdown voltage (V)
Between contacts of same pole
Between coil and contacts
Between contacts of different poles
Between coil and contacts
Impulse Withstand Voltage (European version)
(2 x 10 μs)
(10 x 160 μs)
(10 x 160 μs)
9
15
9
6
10
6
3
0
5
0
3
0
4000
4500
5000
5500
6000
6500
1500
2000
2500
3000
3500
4000
4000
4500
5000
5500
6000
6500
Breakdown voltage (V)
Breakdown voltage (V)
Breakdown voltage (V)
Between coil and contacts
Between contacts of different poles
Between contacts of same pole
Between coil and contacts
Between contacts of different poles
Dielectric Strength (European Version, Non-latching)
Detecting current: 1mA
50
40
50
40
30
20
30
20
10
0
10
0
1500
2000
2500
3000
3500
4000
1500
2000
2500
3000
3500
4000
Breakdown voltage (V)
Breakdown voltage (V)
Between coil and contacts
Between contacts of different poles
Between contacts of same pole
Low Signal Relay G6S
83
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Coplanarity is 0.1 mm max.
■ Standard
G6S-2F, G6S-2F-Y
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
(Top View)
Tolerance: 0.1
Orientation mark
G6S-2G, G6S-2G-Y
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
(Top View)
Tolerance: 0.1
Orientation mark
G6S-2, G6S-2-Y
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Bottom View)
Footprint
(Bottom View)
Tolerance: 0.1
Orientation mark
Eight, 1-dia. holes
84
Low Signal Relay G6S
■ Single Coil Latching
G6SU-2F
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
(Top View)
Tolerance: 0.1
7.3+0.2
Orientation mark
G6SU-2G
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
7.3+0.2
(Top View)
Tolerance: 0.1
Orientation mark
G6SU-2
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Bottom View)
Footprint
(Bottom View)
Tolerance: 0.1
Eight, 1-dia. holes
Orientation mark
Low Signal Relay G6S
85
■ Dual Coil Latching
G6SK-2F
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
(Top View)
Tolerance: 0.1
Orientation mark
G6SK-2G
Tolerance: 0.3
7.3+0.2
Terminal Arrangement/
Internal Connections
(Top View)
Footprint
(Top View)
Tolerance: 0.1
Orientation mark
G6SK-2
Tolerance: 0.3
Terminal Arrangement/
Internal Connections
(Bottom View)
Footprint
(Bottom View)
Tolerance: 0.1
Orientation mark
Ten, 1-dia. holes
Recommended Soldering Method
(1) IRS Method (Mounting Solder: Lead)
(2) IRS Method (Mounting Solder: Lead-free)
Upper surface of case (peak):
255°C max.
Soldering
Soldering
220 to
240
250 max.
230
180 to
200
180
Preheating
Preheating
150
150
Relay
terminal
section
20 to 30
120 max.
30 max.
Time (s)
Note: The temperature profile indicates the
temperature of the relay terminal section.
90 to 120
Time (s)
86
Low Signal Relay G6S
Packaging
Tube packing
Standard nomenclature
50 pcs per anti-static tube
Tape packing (Surface mount versions)
When ordering, add “TR” before the rated coil voltage (e.g., G6S-2F-TR-DC12)
Note: TR is not part of the relay model number and will not be marked on the relay.
■ Tape and Reel Dimensions (Surface Mount Models)
• Tape type: TE2416R (Refer to EIAJ - Electronic Industrial Association of Japan)
• Reel type: R24E (Refer to EIAJ - Electronic Industrial Association of Japan)
• Relays per reel: 400
• Reels per packing carton: 2 (800 relays)
29.5 1.0
G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y
25.5 0.5
2 0.3
2 10.5
330
80
R1.0
13 0.2
G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y
Cover tape
Carrier tape
Emboss tape
Orientation mark
Feed direction
■ Approvals
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C
Type
Contact form
DPDT
Coil rating
2 to 48 VDC
2 to 24 VDC
Contact ratings
Number of test operations
6,000
G6S-2, G6S-2F, G6S-2G
3 A at 30 VDC (Resistive)
0.3 A at 110 VDC (Resistive)
0.5 A at 125 VAC (General Use)
G6SU-2, G6SU-2F, G6SU-2G
G6SK-2, G6SK-2F, G6SK-2G
G6SK-2-Y, G6SK-2F-Y, G6SK-2G-Y
EN60950 / EN41003
Type
Contact form
Isolation Category
Voltage
G6S-2-Y, G6S-2F-Y, G6S-2G-Y
DPDT
Supplementary Isolation
250 VAC
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics
individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
Low Signal Relay G6S
87
Precautions
•
•
•
Use a DC power supply with 5% or less ripple factor to operate the coil.
Do not use the G6S where subject to strong external magnetic fields.
Do not use the G6S where subject to magnetic particles or excessive
• Latching types are delivered in the reset position. We recommend
that a reset voltage be applied in advance to start operation.
• Do not drop the G6S or otherwise subject it to excessive shock.
• Remove the relay from the packing immediately prior to usage.
amounts of dust
.
• Do not reverse the polarity of the coil (+, −).
■ Correct use
Long-term Continuously ON Contacts
G6S (K) (-U) -2 Soldering
• Soldering temperature: Approx. 250°C (At 260°C if the DWS
Using the Relay in a circuit where the Relay will be ON continuously
for long periods (without switching) can lead to unstable contacts
because the heat generated by the coil itself will affect the insulation,
causing a film to develop on the contact surfaces. We recommend
using a latching relay (magnetic-holding relay) in this kind of circuit. If
a single-side stable model must be used in this kind of circuit, we rec-
ommend using a fail-safe circuit design that provides protection
against contact failure or coil burnout.
method is used.)
• Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and
approx. 3 s for the second time if the DWS method is used.)
• Be sure to adjust the level of the molten solder so that the solder
will not overflow onto the PCB.
Claw Securing Force During Automatic Mounting
During automatic insertion of Relays, be sure to set the securing
force of each claw to the following so that the Relay’s characteristics
will be maintained.
Relay Handling
Use the Relay as soon as possible after opening the moisture-proof
package. If the Relay is left for a long time after opening the mois-
ture-proof package, the appearance may suffer and seal failure may
occur after the solder mounting process. To store the Relay after
opening the moisture-proof package, place it into the original pack-
age and sealed the package with adhesive tape.
C
B
A
When washing the product after soldering the Relay to a PCB, use a
water-based solvent or alcohol-based solvent, and keep the solvent
temperature to less than 40°C. Do not put the Relay in a cold clean-
ing bath immediately after soldering.
Dimension A: 1.96 N max.
Dimension B: 4.90 N max.
Dimension C: 1.96 N max.
88
Low Signal Relay G6S
MEMO
Low Signal Relay G6S
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
Low Signal Relay G6S
相关型号:
G6SK-2G-DC3
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.067A (COIL), 3VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-DC4.5
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.044A (COIL), 4.5VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-DC5
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.04A (COIL), 5VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-DC9
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.022A (COIL), 9VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-H-DC12
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.012A (COIL), 12VDC (COIL), 140mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-H-DC4.5
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.031A (COIL), 4.5VDC (COIL), 140mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
G6SK-2G-H-DC5
POWER/SIGNAL RELAY, DPDT, LATCHED, 0.028A (COIL), 5VDC (COIL), 140mW (COIL), 2A (CONTACT), 30VDC (CONTACT), SURFACE MOUNT-STRAIGHT, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明