G6SK-2-H-TRDC5 [OMRON]

Power/Signal Relay, DPDT, Latched, 0.028A (Coil), 5VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
G6SK-2-H-TRDC5
型号: G6SK-2-H-TRDC5
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, DPDT, Latched, 0.028A (Coil), 5VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

光电二极管 继电器
文件: 总12页 (文件大小:723K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
GLow6SigSnal Relay  
Suface Mount DPDT Relay  
• High dielectric withstand voltage of 2,000 VAC between coil  
and contacts (standard type); 1,500 VAC between contacts  
of different polarity.  
• Meets FCC Part 68 and Telcordia 2.5 kV surge withstand.  
• European version certified for EN60950/EN41003 Supple-  
mentary Insulation at 250 V at Pollution Degree 2.  
• Low power consumption of 140 mW (Non-latching)  
• Available in through-hole and SMT terminals.  
Tape and reel or tube packaging.  
• RoHS Compliant.  
Ordering Information  
Standard Version  
.
Model  
Contact form  
DPDT  
Non-latching  
Terminal  
Gull-wing  
Single coil latching  
Dual coil latching  
Standard  
G6S-2F  
European Version*  
G6S-2F-Y  
G6S-2G-Y  
G6S-2-Y  
G6SU-2F  
G6SU-2G  
G6SU-2  
G6SK-2F  
G6SK-2G  
G6SK-2  
Inside “L”  
G6S-2G  
G6S-2  
PCB through-hole  
* Certified for EN60950/EN41003 Supplementary Insulation at 250 V (pollution degree 2)  
Notes: 1. When ordering, add the rated coil voltage to the model number.  
Example: G6S-2F DC12  
Rated coil voltage  
2. When ordering tape packing (surface mount models), add "-TR" to the model number.  
Example: G6S-2F-TR DC12  
Tape packing  
"-TR" is not part of the relay model number. Therefore, it is not marked on the relay case.  
3. Dual coil latching models are available with a High-sensitivity coil. (140 mW; 200 mW for DC24)  
When ordering High-sensitivity dual coil latching models, add "-H” to the model number.  
Example: G6SK-2G-H-TR DC5  
High-sensitivity coil  
Model Number Legend  
G6S  
-
-
-
DC  
1
2 3  
4
5
6
5. Packaging  
None: Tube packaging  
3. Terminal Shape  
None: Through-hole  
1. Relay Function  
None: Non-latching  
TR:  
Tape and reel packaging  
U:  
K:  
Single coil latching  
Dual coil latching  
F:  
Gull-wing surface mount  
Inside “Lsurface mount  
(Surface mount models)  
G:  
2. Contact Form  
4. Approved Standards  
6. Rated Coil Voltage  
3, 4.5, 5, 12, 24 VDC  
2: DPDT  
None: UL/CSA  
Y:  
EN60950/EN41003  
(Standard coil models - 5, 12, 24 VDC )  
Low Signal Relay G6S  
79  
Specification  
Contact Data  
Load  
Resistive load (cos φ = 1)  
Rated load  
0.5 A at 125 VAC  
2 A at 30 VDC  
Contact material  
Max. carry current  
Ag (Au clad)  
2 A  
Max. operating voltage  
Max. operating current  
Max. switching capacity  
Min. permissible load  
250 VAC, 220 VDC  
2 A  
62.5 VA, 60 W  
10 μA, 10 mVDC  
Note: P level: λ60 = 0.1 x 10-6/operation  
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 Ω. This value may vary  
depending on the operating environment. Always double-check relay suitability under actual operating conditions.  
Coil Data  
G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2)  
Pick-up  
voltage  
Dropout  
voltage  
% of rated voltage  
Maximum  
voltage  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power consumption (mW)  
3
4.5  
5
12  
24  
46.7  
64.3  
145  
178  
1,028  
2,880  
75% max.  
10% min.  
200% max.@ 23°C Approx. 140  
31.0  
28.1  
11.7  
8.3  
170% max.@ 23°C Approx. 200  
G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2)  
Coil Inductance (H)  
(ref. value)  
Armature OFF Armature ON  
Set pick-up Reset pick-up  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power  
consumption  
(mW)  
Maximum volt-  
age  
voltage  
voltage  
% of rated voltage  
3
4.5  
5
12  
24  
33.3  
90  
203  
250  
1,440  
3,840  
0.108  
0.27  
0.36  
2.12  
5.80  
0.069  
0.14  
0.18  
1.14  
3.79  
75% max.  
75% max.  
180% max.  
@ 23°C  
Approx. 100  
22.2  
20.0  
8.3  
6.3  
Approx. 150  
G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2)  
Coil Inductance (H)  
(ref. value)  
Set  
pick-up  
voltage  
Reset  
pick-up  
voltage  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Power  
consumption  
(mW)  
Maximum  
voltage  
Set  
Armature Armature Armature Armature  
OFF ON OFF ON  
0.045 0.035 0.032 0.045  
Reset  
% of rated voltage  
3
4.5  
5
12  
24  
66.6  
45  
75% max. 75% max. 170% max. Approx. 200  
@ 23°C  
44.4  
40  
16.7  
12.5  
101  
125  
720  
1,920  
0.12  
0.14  
0.60  
1.98  
0.074  
0.088  
0.41  
0.082  
0.098  
0.46  
0.14  
0.16  
0.54  
2.23  
1.23  
1.34  
140% max. Approx. 300  
@ 23°C  
G6S - European Version, Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
Pick-up  
voltage  
Dropout  
voltage  
% of rated voltage  
Maximum  
voltage  
Power consumption (mW)  
5
40.0  
125  
75% max.  
10% min.  
170% max.@ 23°C Approx. 200  
12  
24  
16.7  
9.6  
720  
2,504  
Approx. 230  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of 10%.  
2. The operating characteristics are measured at a coil temperature of 23°C.  
3. Pick-up voltage will vary with temperature.  
4. The maximum voltage is the highest voltage that can be imposed on the relay coil.  
80  
Low Signal Relay G6S  
Characteristics  
Contact resistance (See note 1)  
Operate (set) time (See note 2)  
Release (reset) time (See note 2)  
Bounce time  
75 mΩ max.  
4 ms max. (mean value approx. 2.5 ms G6S; 2.0 ms G6SU, G6SK)  
4 ms max. (mean value approx. 1.5 ms G6S; 2.0 ms G6SU, G6SK)  
Approx. 0.5 ms  
Max. operating frequency  
Mechanical: 36,000 operations/hr  
Electrical: 1,800 operations/hr (under rated load)  
Insulation resistance (See note 3)  
Dielectric strength  
1,000 MΩ min. (at 500 VDC)  
2,000 VAC, 50/60 Hz for 1 minute (G6S, G6SU) between coil and contacts  
1,000 VAC, 50/60 Hz for 1 minute (G6SK) between coil and contacts  
1,500 VAC, 50/60 Hz for 1 minute between contacts of different poles  
1,000 VAC, 50/60 Hz for 1 minute between contacts of same pole  
500 VAC, 50/60 Hz for 1 minute between set and reset coils (G6SK)  
Surge withstand voltage Conforming to  
Telcordia specs.  
2,500 V (2 x 10 μS) between coil and contacts for G6S and G6SU  
2,500 V (2 x 10 μS) between contacts of different poles  
Conforming to  
FCC Part 68  
1,500 V (10 x 160 μS) between coil and contacts for G6SK  
1,500 V (10 x 160 μS) between contacts of same pole  
Vibration  
Shock  
Mechanical durability 10 to 55 Hz; 5 mm double amplitude  
Malfunction durability 10 to 55 Hz; 3.3 mm double amplitude  
1,000 m/s2; approx. 100 G  
750 m/s2; approx. 75 G  
Mechanical durability  
Malfunction durability  
Ambient temperature  
Ambient Humidity  
Service life  
-40 to +85°C with no icing; -40 to +70°C with no icing (G6SK, DC24 coil)  
5% to 85% RH  
Mechanical  
Electrical  
100,000,000 operations min. (at 36,000 operations/hour)  
100,000 operations min. (2A@30VDC, resistive; 1,200 ops/hr.)  
100,000 operations min. (0.5A@125VAC, resistive)  
See “Characteristic Data”  
Weight  
Approx. 2g  
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.  
2. Values in parentheses are typical values unless otherwise stated.  
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking  
the dielectric strength (except between the set and reset coil).  
4. Data shown are of initial value.  
Characteristic Data  
Service Life  
1000  
500  
1000  
500  
1000  
500  
300  
200  
300  
200  
300  
200  
100  
50  
100  
50  
100  
50  
30  
20  
30  
20  
30  
20  
10  
10  
10  
0
0.2  
0.4  
0.6  
0.8  
1.0  
0
0.1  
0.2  
0.3  
0.4  
0.5  
0
0.2  
0.4  
0.6  
0.8  
1.0  
Service life (x106 operations)  
Resistive load: 100 mA, 50 VDC  
Ambient temperature: +85˚  
Service life (x106 operations)  
Service life (x106 operations)  
Resistive load: 10 mA, 10 VDC  
Ambient temperature: +85˚  
Resistive load: 100 mA, 28 VDC  
Ambient temperature: +85˚  
Low Signal Relay G6S  
81  
Maximum Switching Capacity  
Ambient Temperature vs.  
Maximum Coil Voltage  
Non-latching  
Single Coil Latching  
Dual Coil Latching  
12 VDC max.  
G6SU  
AC resistive load  
24 VDC  
(G6S-Y, 12 VDC max.)  
G6SK  
12 VDC  
max.  
G6SK  
24 VDC  
24 VDC  
(G6S-Y)  
DC resistive load  
Switching voltage (V)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the maximum value in a varying range of  
operating power voltage, not a continuous voltage.  
Reference Data  
Ambient Temperature vs. Switching Current  
Non-latching  
Single Coil Latching  
Dual Coil Latching  
G6SU  
12 VDC max.  
G6SU  
12 VDC max.  
24 VDC  
G6SK  
12 VDC max.  
24 VDC  
(G6S-Y)  
24 VDC  
G6SK  
24 VDC  
(G6S-Y, 12 VDC  
max.)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Electrical Service Life  
Dielectric Strength (Standard Version, Non-latching)  
Detecting current: 1mA  
50  
40  
50  
500  
300  
200  
40  
100  
30  
20  
30  
20  
30 VDC  
70  
50  
30  
125 VAC  
10  
0
10  
0
10  
0
0.4  
0.8  
1.2  
1.6  
2.0  
1000  
1500  
2000  
2500  
3000  
3500  
1000  
1500  
2000  
2500  
3000  
3500  
Breakdown voltage (V)  
Rated operating current (A)  
Breakdown voltage (V)  
Between coil and contacts  
Between contacts of different poles  
Between contacts of same pole.  
82  
Low Signal Relay G6S  
Impulse Withstand Voltage (Standard Version, Non-latching)  
(2 x 10 μs)  
(10 x 160 μs)  
(10 x 160 μs)  
15  
9
9
10  
6
3
6
5
0
3
0
0
1500  
2000  
2500  
3000  
3500  
4000  
3500  
4000  
4500  
5000  
5500  
6000  
3500  
4000  
4500  
5000  
5500  
6000  
Breakdown voltage (V)  
Breakdown voltage (V)  
Breakdown voltage (V)  
Between contacts of same pole  
Between coil and contacts  
Between contacts of different poles  
Between coil and contacts  
Impulse Withstand Voltage (European version)  
(2 x 10 μs)  
(10 x 160 μs)  
(10 x 160 μs)  
9
15  
9
6
10  
6
3
0
5
0
3
0
4000  
4500  
5000  
5500  
6000  
6500  
1500  
2000  
2500  
3000  
3500  
4000  
4000  
4500  
5000  
5500  
6000  
6500  
Breakdown voltage (V)  
Breakdown voltage (V)  
Breakdown voltage (V)  
Between coil and contacts  
Between contacts of different poles  
Between contacts of same pole  
Between coil and contacts  
Between contacts of different poles  
Dielectric Strength (European Version, Non-latching)  
Detecting current: 1mA  
50  
40  
50  
40  
30  
20  
30  
20  
10  
0
10  
0
1500  
2000  
2500  
3000  
3500  
4000  
1500  
2000  
2500  
3000  
3500  
4000  
Breakdown voltage (V)  
Breakdown voltage (V)  
Between coil and contacts  
Between contacts of different poles  
Between contacts of same pole  
Low Signal Relay G6S  
83  
Dimensions  
Note: 1. All units are in millimeters unless otherwise indicated.  
2. Coplanarity is 0.1 mm max.  
Standard  
G6S-2F, G6S-2F-Y  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
(Top View)  
Tolerance: 0.1  
Orientation mark  
G6S-2G, G6S-2G-Y  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
(Top View)  
Tolerance: 0.1  
Orientation mark  
G6S-2, G6S-2-Y  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Footprint  
(Bottom View)  
Tolerance: 0.1  
Orientation mark  
Eight, 1-dia. holes  
84  
Low Signal Relay G6S  
Single Coil Latching  
G6SU-2F  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
(Top View)  
Tolerance: 0.1  
7.3+0.2  
Orientation mark  
G6SU-2G  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
7.3+0.2  
(Top View)  
Tolerance: 0.1  
Orientation mark  
G6SU-2  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Footprint  
(Bottom View)  
Tolerance: 0.1  
Eight, 1-dia. holes  
Orientation mark  
Low Signal Relay G6S  
85  
Dual Coil Latching  
G6SK-2F  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
(Top View)  
Tolerance: 0.1  
Orientation mark  
G6SK-2G  
Tolerance: 0.3  
7.3+0.2  
Terminal Arrangement/  
Internal Connections  
(Top View)  
Footprint  
(Top View)  
Tolerance: 0.1  
Orientation mark  
G6SK-2  
Tolerance: 0.3  
Terminal Arrangement/  
Internal Connections  
(Bottom View)  
Footprint  
(Bottom View)  
Tolerance: 0.1  
Orientation mark  
Ten, 1-dia. holes  
Recommended Soldering Method  
(1) IRS Method (Mounting Solder: Lead)  
(2) IRS Method (Mounting Solder: Lead-free)  
Upper surface of case (peak):  
255°C max.  
Soldering  
Soldering  
220 to  
240  
250 max.  
230  
180 to  
200  
180  
Preheating  
Preheating  
150  
150  
Relay  
terminal  
section  
20 to 30  
120 max.  
30 max.  
Time (s)  
Note: The temperature profile indicates the  
temperature of the relay terminal section.  
90 to 120  
Time (s)  
86  
Low Signal Relay G6S  
Packaging  
Tube packing  
Standard nomenclature  
50 pcs per anti-static tube  
Tape packing (Surface mount versions)  
When ordering, add “TR” before the rated coil voltage (e.g., G6S-2F-TR-DC12)  
Note: TR is not part of the relay model number and will not be marked on the relay.  
Tape and Reel Dimensions (Surface Mount Models)  
Tape type: TE2416R (Refer to EIAJ - Electronic Industrial Association of Japan)  
Reel type: R24E (Refer to EIAJ - Electronic Industrial Association of Japan)  
Relays per reel: 400  
Reels per packing carton: 2 (800 relays)  
29.5 1.0  
G6S-2F, G6SU-2F, G6SK-2F, G6S-2F-Y  
25.5 0.5  
2 0.3  
2 10.5  
330  
80  
R1.0  
13 0.2  
G6S-2G, G6SU-2G, G6SK-2G, G6S-2G-Y  
Cover tape  
Carrier tape  
Emboss tape  
Orientation mark  
Feed direction  
Approvals  
UL Recognized (File No. E41515) / CSA Certified (File No. LR31928) - - Ambient Temp. = 40°C  
Type  
Contact form  
DPDT  
Coil rating  
2 to 48 VDC  
2 to 24 VDC  
Contact ratings  
Number of test operations  
6,000  
G6S-2, G6S-2F, G6S-2G  
3 A at 30 VDC (Resistive)  
0.3 A at 110 VDC (Resistive)  
0.5 A at 125 VAC (General Use)  
G6SU-2, G6SU-2F, G6SU-2G  
G6SK-2, G6SK-2F, G6SK-2G  
G6SK-2-Y, G6SK-2F-Y, G6SK-2G-Y  
EN60950 / EN41003  
Type  
Contact form  
Isolation Category  
Voltage  
G6S-2-Y, G6S-2F-Y, G6S-2G-Y  
DPDT  
Supplementary Isolation  
250 VAC  
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics  
individually defined in this catalog.  
2. In the interest of product improvement, specifications are subject to change.  
Low Signal Relay G6S  
87  
Precautions  
Use a DC power supply with 5% or less ripple factor to operate the coil.  
Do not use the G6S where subject to strong external magnetic fields.  
Do not use the G6S where subject to magnetic particles or excessive  
Latching types are delivered in the reset position. We recommend  
that a reset voltage be applied in advance to start operation.  
Do not drop the G6S or otherwise subject it to excessive shock.  
Remove the relay from the packing immediately prior to usage.  
amounts of dust  
.
Do not reverse the polarity of the coil (+, ).  
Correct use  
Long-term Continuously ON Contacts  
G6S (K) (-U) -2 Soldering  
Soldering temperature: Approx. 250°C (At 260°C if the DWS  
Using the Relay in a circuit where the Relay will be ON continuously  
for long periods (without switching) can lead to unstable contacts  
because the heat generated by the coil itself will affect the insulation,  
causing a film to develop on the contact surfaces. We recommend  
using a latching relay (magnetic-holding relay) in this kind of circuit. If  
a single-side stable model must be used in this kind of circuit, we rec-  
ommend using a fail-safe circuit design that provides protection  
against contact failure or coil burnout.  
method is used.)  
Soldering time: Approx. 5 s max. (Approx. 2 s for the first time and  
approx. 3 s for the second time if the DWS method is used.)  
Be sure to adjust the level of the molten solder so that the solder  
will not overflow onto the PCB.  
Claw Securing Force During Automatic Mounting  
During automatic insertion of Relays, be sure to set the securing  
force of each claw to the following so that the Relay’s characteristics  
will be maintained.  
Relay Handling  
Use the Relay as soon as possible after opening the moisture-proof  
package. If the Relay is left for a long time after opening the mois-  
ture-proof package, the appearance may suffer and seal failure may  
occur after the solder mounting process. To store the Relay after  
opening the moisture-proof package, place it into the original pack-  
age and sealed the package with adhesive tape.  
C
B
A
When washing the product after soldering the Relay to a PCB, use a  
water-based solvent or alcohol-based solvent, and keep the solvent  
temperature to less than 40°C. Do not put the Relay in a cold clean-  
ing bath immediately after soldering.  
Dimension A: 1.96 N max.  
Dimension B: 4.90 N max.  
Dimension C: 1.96 N max.  
88  
Low Signal Relay G6S  
MEMO  
Low Signal Relay G6S  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
Low Signal Relay G6S  

相关型号:

G6SK-2-H-TRDC6

Power/Signal Relay, DPDT, Latched, 0.023A (Coil), 6VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-H-TRDC9

Power/Signal Relay, DPDT, Latched, 0.016A (Coil), 9VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC12

Power/Signal Relay, DPDT, Latched, 0.012A (Coil), 12VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC24

Power/Signal Relay, DPDT, Latched, 0.008A (Coil), 24VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC3

Power/Signal Relay, DPDT, Latched, 0.047A (Coil), 3VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC5

Power/Signal Relay, DPDT, Latched, 0.028A (Coil), 5VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC6

Power/Signal Relay, DPDT, Latched, 0.023A (Coil), 6VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-HDC9

Power/Signal Relay, DPDT, Latched, 0.016A (Coil), 9VDC (Coil), 140mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-TR-DC12

POWER/SIGNAL RELAY, DPDT, LATCHED, 0.017A (COIL), 12VDC (COIL), 200mW (COIL), 2A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON

G6SK-2-TR-DC24

POWER/SIGNAL RELAY, DPDT, LATCHED, 0.013A (COIL), 24VDC (COIL), 300mW (COIL), 2A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON

G6SK-2-TRDC12

Power/Signal Relay, DPDT, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6SK-2-TRDC24

Power/Signal Relay, DPDT, Latched, 0.013A (Coil), 24VDC (Coil), 300mW (Coil), 2A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON