G6BK-1114P-US-24VDC [OMRON]

Power/Signal Relay, SPST, Latched, 0.012A (Coil), 24VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT;
G6BK-1114P-US-24VDC
型号: G6BK-1114P-US-24VDC
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Power/Signal Relay, SPST, Latched, 0.012A (Coil), 24VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT

文件: 总10页 (文件大小:1504K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G6B  
PCB Power Relay  
High Capacity and High  
DielectricStrengthMiniature  
Relay with Fully Sealed  
Construction in 5 A (8 A)  
SPST-NO (1a),  
SPST-NC (1b),  
DPST-NO (2a),  
DPST-NC (2b) Types  
• High sensitive with operating power of 98 mW.  
(G6B-1114P-US and G6B-1174P-US models)  
• High insulation with dielectric strength of 3,000VAC  
between coil and contacts (impulse withstand voltage of  
6 kV).  
G
6
B
• Stick packing models are provided in consideration of compatibility to the automatic production line.  
• Standard model conforms to UL/CSA standards. Other SEV approved models are also available.  
• AgSnIn contacts suitable for loads that generate surge voltage (inductive load, capacity load, etc.) available. (-FD type)  
• Ultrasonic cleanable models available. (-U type)  
• Operation indicator & built-in surge absorption diode available. (-ND type)  
• 2-Pole type available.  
Application Examples  
RoHS Compliant  
• Ideal for output applications of control equipments  
Model Number Legend  
G6B-@-@@@@@-@--@-@-@-@  
1
2
3 4 5  
6
7
8
9 10  
1. Relay Function  
3. Classification  
1: Standard  
7. Operation Indicator Diode  
Availability  
None: Single-side stable  
U
K
: Single-winding latching  
7: High-capacity  
None: Standard  
(G6B@-1114 models only)  
: Double-winding latching  
(G6B@-1114 models only)  
ND : Operation indicator & coil surge  
absorption diode  
4. Enclosure rating  
4: Fully sealed  
(for -1177 type only)  
7: Flux protection  
2. Contact Form  
21: SPST-NO + SPST-NC  
22: DPST-NO  
8. Approved Standards  
5. Terminal Shape  
US: UL/CSA  
P: PCB terminals  
Socket mounting terminals  
9. Washability  
20: DPST-NC  
None: Standard  
6. Contact material  
11: SPST-NO  
U
: For ultrasonically cleanable  
None: Standard (Ag-alloy (Cd free))  
FD : AgSnIn contact  
10.Mounting  
(Suitable for DC inductive load with  
high inrush current)  
None: Mounted directly to PCB  
P6B : Mounted to Socket  
1
G6B  
Ordering Information  
PCB Power Relay  
Standard Models (UL, CSA certified)  
Contact material  
Standard (Ag-alloy (Cd free))  
AgSnIn contact  
Number  
of poles  
Minimum  
packing unit  
Relay Function  
Contact form  
Model  
Rated coil voltage  
Model  
Rated coil voltage  
SPST-NO (1a)  
(Standard)  
100  
pcs/tray  
G6B-1114P-US  
5, 6, 12, 24 VDC G6B-1114P-FD-US  
5, 6, 12, 24 VDC  
Single-side stable  
SPST-NO (1a)  
(High-capacity)  
20  
pcs/tube  
G6B-1174P-US  
G6BU-1114P-US  
G6BK-1114P-US  
5, 6, 12, 24 VDC G6B-1174P-FD-US  
5, 6, 12, 24 VDC G6BU-1114P-FD-US  
5, 6, 12, 24 VDC  
5, 12, 24 VDC  
Single-winding  
latching  
SPST-NO (1a)  
(Standard)  
1-pole  
100  
pcs/tray  
5, 6, 12 VDC  
G6BK-1114P-FD-US  
24 VDC  
5, 6, 12 VDC  
24 VDC  
Double-winding  
latching  
SPST-NO (1a)  
(Standard)  
SPST-NO (1a)  
(Built-in high-capacity  
operation indicator &  
diode)  
20  
pcs/tube  
Single-side stable  
G6B-1177P-ND-US  
5, 12, 24 VDC  
G6B-1177P-FD-ND-US 5, 12, 24 VDC  
SPST-NO (1a)+  
SPST-NC (1b) (Standard)  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
5, 6, 12, 24 VDC G6B-2114P-FD-US  
5, 6, 12, 24 VDC G6B-2214P-FD-US  
5, 6, 12, 24 VDC G6B-2014P-FD-US  
5, 6, 12, 24 VDC  
5, 6, 12, 24 VDC  
5, 6, 12, 24 VDC  
DPST-NO (2a)  
(Standard)  
100  
pcs/tray  
2-pole Single-side stable  
DPST-NC (2b)  
(Standard)  
Note: AgSnIn contact models are highly welding-resistant, and roughening of contacts due to inrush current and inductive load is lessened.  
G
6
B
Models for Ultrasonically Cleanable  
Contact material  
Contact form  
Standard (Ag-alloy (CD free))  
AgSnIn contact  
Number  
of poles  
Minimum  
packing unit  
Relay Function  
Model  
Rated coil voltage  
Model  
Rated coil voltage  
SPST-NO (1a)  
(Standard)  
Single-side stable  
G6B-1114P-US-U  
5, 6, 12, 24 VDC G6B-1114P-FD-US-U  
6, 12, 24 VDC  
Single-winding  
latching  
SPST-NO (1a)  
(Standard)  
1-pole  
G6BU-1114P-US-U  
G6BK-1114P-US-U  
G6B-2114P-US-U  
G6B-2214P-US-U  
G6B-2014P-US-U  
24 VDC  
Double-winding  
latching  
SPST-NO (1a)  
(Standard)  
5, 6, 12, 24 VDC G6BK-1114P-FD-US-U 12, 24 VDC  
100  
pcs/tray  
SPST-NO (1a)+  
SPST-NC (1b) (Standard)  
5, 12, 24 VDC  
G6B-2114P-FD-US-U  
5, 12, 24 VDC  
5, 12, 24 VDC  
5, 12, 24 VDC  
DPST-NO (2a)  
(Standard)  
2-pole Single-side stable  
5, 6, 12, 24 VDC G6B-2214P-FD-US-U  
DPST-NC (2b)  
(Standard)  
5, 12, 24 VDC  
G6B-2014P-FD-US-U  
Note: When ordering, add the rated coil voltage to the model number.  
Example: G6B-1114P-US 5 VDC  
Rated coil voltage  
Connecting Sockets (Sold Separately)  
Applicable relay  
Model  
Minimum ordering unit  
G6B-1114P(-FD)-US-P6B  
G6B-1174P(-FD)-US-P6B  
G6B-1177P(-FD)-ND-US-P6B  
G6BU-1114P-US-P6B  
P6B-04P  
20 pcs  
G6BK-1114P-US-P6B  
P6B-06P  
P6B-26P  
G6B-2114P-US-P6B  
G6B-2214P-US-P6B  
G6B-2014P-US-P6B  
Removal Tool  
P6B-Y1  
P6B-C2  
1 pcs  
Hold-down Clips  
Note 1. When using by combining sockets of the G6B-1174P-US and P6B-04P models, the rated current will be  
5A due to its rated switching current.  
2.Use the G6B-@@@@P(-FD)-US P6B to mount to a P6B Socket.  
3.The hold-down clips of the P6B-C2 model are not suitable for the G6B-1174P and G6B-1177P models  
since they have different heights.  
4.Products with UL/CSA certification marks will be supplied for orders of standard models.  
2
G6B  
Ratings  
PCB Power Relay  
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)  
Must operate Must release Max. voltage  
Item  
Rated current Coil resistance  
Power consumption  
(mW)  
voltage (V)  
voltage (V)  
(V)  
(mA)  
(Ω)  
Rated voltage  
% of rated voltage  
5 VDC  
6 VDC  
40  
125  
180  
33.3  
16.7  
8.3  
160%  
(at 23°C)  
70% max.  
10% min.  
Approx. 200  
12 VDC  
24 VDC  
720  
2,880  
Coil: 2-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)  
Must operate Must release Max. voltage  
Item  
Rated current Coil resistance  
Power consumption  
(mW)  
voltage (V)  
voltage (V)  
(V)  
(mA)  
(Ω)  
Rated voltage  
% of rated voltage  
5 VDC  
6 VDC  
60  
83.3  
50  
120  
480  
140%  
(at 23°C)  
80% max.  
10% min.  
Approx. 300  
12 VDC  
24 VDC  
25  
12.5  
1,920  
Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)  
Must set Must reset Max. voltage  
Item  
Power consumption  
Rated  
current  
(mA)  
Coil  
resistance  
(Ω)  
voltage (V) voltage (V)  
(V)  
Set coil  
(mW)  
Reset coil  
(mW)  
% of rated voltage  
Rated voltage  
5 VDC  
6 VDC  
40  
125  
180  
G
6
B
33.3  
16.7  
8.3  
160%  
(at 23°C)  
70% max. 70% max.  
200  
200  
12 VDC  
24 VDC  
720  
2,880  
Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)  
Must set voltage Must reset voltage Max. voltage  
Rated current (mA)  
Coil resistance (Ω)  
Power consumption  
Item  
(V)  
(V)  
(V)  
Set coil  
(mW)  
Reset coil  
(mW)  
Rated voltage  
Set coil  
Reset coil  
Set coil Reset coil  
% of rated voltage  
5 VDC  
6 VDC  
56  
56  
89.2  
128.5  
515  
89.2  
128.5  
515  
46.8  
23.3  
11.7  
46.8  
23.3  
11.7  
130%  
(at 23°C)  
70% max.  
70% max.  
280  
280  
12 VDC  
24 VDC  
2,060  
2,060  
Coil: Operation Indicator Model (Flux-resistant type. Do not wash down with water.)  
Must operate Must release Max. voltage  
Item  
Rated current Coil resistance  
Power consumption  
(mW)  
voltage (V)  
voltage (V)  
(V)  
(mA)  
(Ω)  
Rated voltage  
% of rated voltage  
5 VDC  
12 VDC  
24 VDC  
43  
116  
610  
Approx. 200  
Approx. 240  
Approx. 275  
130%  
(at 23°C)  
19.7  
11.3  
70% max.  
10% min.  
2,120  
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.  
2.The operating characteristics are measured at a coil temperature of 23°C.  
3.The “Max. voltage” is the maximum voltage that can be applied to the relay coil.  
Contacts  
G6B-1114P-US  
G6BU-1114P-US  
G6BK-1114P-US  
G6B-1114P-FD-US  
G6BU-1114P-FD-US  
G6BK-1114P-FD-US  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
G6B-2114P-FD-US  
G6B-2214P-FD-US  
G6B-2014P-FD-US  
G6B-1174P-US  
G6B-1177P-ND-US  
G6B-1174P-FD-US  
G6B-1177P-FD-ND-US  
Model  
Load  
Inductive load  
= 0.4; L/R = 7 ms)  
Inductive load  
= 0.4; L/R = 7 ms)  
Inductive load  
(cosφ = 0.4; L/R = 7 ms)  
Resistive load  
Resistive load  
Resistive load  
Item  
(cosφ  
(cos  
φ
Contact type  
Contact material  
Single  
Ag-Alloy (Cd free)  
5 A (3 A) at 250 VAC  
5 A (3 A) at 30 VDC  
2 A (2 A) at 250 VAC  
2 A (2 A) at 30 VDC  
8 A (5 A) at 250 VAC  
8 A (5 A) at 30 VDC  
2 A (2 A) at 250 VAC  
2 A (2 A) at 30 VDC  
5 A (3 A) at 250 VAC 1.5 A (1.5 A) at 250 VAC  
5 A (3 A) at 30 VDC 1.5 A (1.5 A) at 30 VDC  
5 A (5 A)  
Rated load  
Rated carry current  
5 A (5 A)  
8 A (5 A)  
Max. switching voltage  
Max. switching current  
380 VAC, 125 VDC  
8 A (5 A)  
5 A (5 A)  
5 A (5 A)  
Note 1. The values in the parentheses ( ) are for -FD models only.  
2.Use the -FD type for inductive load and switching load which contact roughening is small.  
3
G6B  
Characteristics  
PCB Power Relay  
G6B-2114P-US  
G6B-2114P-FD-US  
G6B-2214P-US  
G6B-1114P-US  
G6B-1114P-FD-US  
G6B-1174P-US  
G6B  
Model  
G6BU-1114P-US  
G6BK-1114P-US  
-1177P(-FD)-ND-US G6B-2214P-FD-US  
G6B-2014P-US  
G6B-1174P-FD-US  
G6B-2014P-FD-US  
Built-in operation  
indicator & surge  
absorption diode  
Single-winding  
latching  
Double-winding  
latching  
Item  
Classification Single-side stable  
Single-side stable  
Contact resistance *1  
Operate (set) time  
Release (reset) time  
Min. set pulse width  
Min. reset pulse width  
Insulation resistance *2  
30 mΩ max.  
10 ms max.  
10 ms max.  
15 ms (at 23°C)  
15 ms (at 23°C)  
1,000 MΩ min.  
2,000 VAC,  
50/60 Hz for 1 min  
Between coil and contacts  
3,000 VAC, 50/60 Hz for 1 min  
3,000 VAC, 50/60 Hz for 1 min  
Between contacts of the same  
polarity  
Between contacts of different  
polarity  
1,000 VAC, 50/60 Hz for 1 min  
Dielectric strength  
2,000 VAC,  
50/60 Hz for 1 min  
250 VAC,  
50/60 Hz for 1 min  
Between set and reset coils  
Impulse withstand voltage (between coil and contacts)  
6 kV 1.2 × 50 μs  
4.5 kV 1.2 × 50 μs  
6 kV 1.2 × 50 μs  
Destruction  
Malfunction  
Destruction  
Malfunction  
Mechanical  
Electrical  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)  
1,000 m/s2  
Vibration  
resistance  
Shock resistance  
Durability  
G
6
B
100 m/s2  
300 m/s2  
100 m/s2  
50,000,000 operations min. (at 18,000 operations/hr)  
100,000 operation min. (at 1,800 operations/hr under rated load)  
10 mA at 5 VDC  
Failure rate (P level) (reference value) *3  
Ambient operating temperature  
Ambient operating humidity  
Weight  
-25°C to 70°C (with no icing or condensation)  
5% to 85%  
Approx. 3.5 to 4.6 g  
Approx. 3.5 g  
Approx. 3.7 g  
Approx. 5.4 g  
Approx. 4.5 g  
Note 1. The values here are initial values.  
2.The G6B-1177P(-FD)-ND model is flux-resistant. Do not wash it down with water.  
*1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.  
*2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was  
measured.(Except the location between set/reset coil)  
*3. This value was measured at a switching frequency of 120 operations/min.  
4
G6B  
Engineering Data  
PCB Power Relay  
Maximum Switching Current  
G6B-1114P-US  
G6B-1174P-FD-US  
40  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
G6B-1174P-US  
100  
100  
50  
30  
50  
30  
20  
10  
G6B-2114P-FD-US  
G6B-2214P-FD-US  
G6B-2014P-FD-US  
AC inductive load  
(cosφ = 0.4)  
AC resistive load  
AC resistive load  
5
10  
8
10  
AC resistive  
load  
3
2
5
5
3
AC  
inductive  
load  
cosφ = 0.4  
3
2
DC inductive load  
(L/R = 7 ms)  
2
1.5  
1
1
DC resistive load  
AC  
inductive  
load  
AC  
1
resistive  
load  
DC resistive load  
0.5  
DC resistive load  
0.5  
0.3  
0.5  
0.3  
0.3  
0.2  
DC inductive load  
DC inductive load  
(L/R = 7 ms)  
0.1  
0.1  
0.1  
0
3
5
10 20 30  
100  
300 500  
0
3
5
10  
30 50 100  
380 1,000  
0
3
5
10  
30 50 100  
300 500 1,000  
Switching voltage (V)  
Switching voltage (V)  
Switching voltage (V)  
Ambient Temperature vs.  
Durability  
Maximum Coil Voltage  
G6B-1114P-US  
G6B-1174P-US  
G6B-1174P-FD-US  
G6B-2114P(-FD)-US  
G6B-2214P(-FD)-US  
G6B-2014P(-FD)-US  
G6B-1114P-US  
G6B-1174P-US  
G6B-1174P-FD-US  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
1,000  
1,000  
200  
G
6
B
G6B-2114P(-FD)-US  
500  
G6B-1114P-US  
250 VAC/30 VDC resistive load  
500  
300  
G6B-2214P(-FD)-US  
G6B-2014P(-FD)-US  
250 VAC/30 VDC inductive load  
(cosφ = 0.4, L/R = 7 ms)  
180  
G6B-1114P-US  
G6B-1174P-US  
G6B-1174P-FD-US  
300  
G6B-1174P-FD-US  
250 VAC/30 VDC resistive load  
160  
100  
100  
G6B-1174P-US  
250 VAC/30 VDC  
resistive load  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
140  
130  
120  
110  
100  
50  
30  
50  
30  
250 VAC/30 VDC resistive load  
10  
10  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
Higher  
capacity  
G6B-1114P-US  
G6B-1174P-FD-US  
G6B-1174P-US  
G6B-2114P-FD-US  
G6B-2214P-FD-US  
G6B-2014P-FD-US  
250 VAC resistive load  
5
3
5
3
80  
60  
250 VAC/30 VDC inductive load  
(cosφ = 0.4, L/R = 7 ms)  
1
1
0
1
2
3
4
5
6
7
8
9
10  
0
1 1.5 2  
3
4
5
6
7
8
9
10  
0
20 23 30  
40  
50  
60  
70  
80 90  
Switching current (A)  
Switching current (A)  
Ambient temperature (°C)  
Note: The maximum coil voltage refers to the  
maxi-mum value in a varying range of  
operating power voltage, not a continuous  
voltage.  
Ambient Temperature vs. Must  
Operate and Must Release Voltage  
G6B-1114P-US  
Mutual Magnetic Interference  
G6B-1114P-US  
G6B-1114P-US  
Must operate voltage  
Must release voltage  
Must operate voltage  
Must release voltage  
100  
Sample:  
G6B-1114P-US  
Number of Relays: 5 pcs  
Must operate voltage  
Must release voltage  
Initial stage  
Test  
Initial stage  
Test  
2.54 mm  
+1.0  
+1.0  
max.  
80  
60  
40  
20  
X
+0.5  
+0.5  
min.  
2.54 mm  
0
0
Sample  
De-energized  
0.5  
1.0  
0.5  
Sample  
Average value  
Average value  
1.0  
max.  
De-energized  
Initial stage  
Initial stage  
Test  
Test  
Sample  
X
+1.0  
+1.0  
min.  
+0.5  
+0.5  
Sample  
0
0
Energized  
0.5  
1.0  
0.5  
1.0  
0
40  
20  
0
20  
40  
60  
80  
Average value  
Average value  
Energized  
Ambient temperature (°C)  
5
G6B  
Shock Malfunction  
PCB Power Relay  
Y
Y
Y
Reset  
1,000  
1,000  
Energized  
Energized  
Set  
300  
X
400  
Z
X
1,000  
X
1,000  
Z
Z
1,000  
1,000  
300  
700  
600  
100  
100  
200  
200  
400  
X'  
1,000  
X'  
1,000  
Z'  
1,000  
Z'  
1,000  
X'  
300  
Z'  
300  
Unit: m/s2  
1,000  
Y'  
1,000  
Y'  
Unit: m/s2  
Unit: m/s2  
Y'  
Sample: G6B-1174P-US  
G6B-1174P-FD-US  
Test Conditions: Shock is applied in ±X, ±Y,  
and ±Z directions three times each with without  
Sample: G6B-1114P-US  
Number of Relays: 12 pcs  
Test Conditions: Shock is applied in ±X, ±Y,  
and ±Z directions three times each with without  
Sample: G6BK-1114P-US  
Number of Relays: 12 pcs  
Test Conditions: The value at which  
malfunction occurred was measured after  
applying shock to the  
energizing the Relays  
to check the number of  
malfunctions.  
energizing the Relays  
Shock direction  
Shock direction  
Shock direction  
X
X'  
X
X'  
to check the number of  
malfunctions.  
X
X'  
test piece 3 times each  
in 6 directions along 3  
Y
Y
Y
Z
Z
Z
Requirement: None  
Requirement: None  
axes.  
Z'  
Z'  
malfuction 100 m/s2  
malfuction 100 m/s2  
Z'  
Standard value:  
300 m/s2  
Y'  
Y'  
(Coil)  
Y'  
(Coil)  
(Coil)  
Hot Start  
40  
40  
40  
30  
Sample: G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
Test: the variation of operating voltage is  
measured based on coil cold start at 23°C, during  
which rated voltage is applied to the coil with rated  
contact current (5A), and left  
for 1 hour each under different  
ambient temperatures.  
Sample: G6B-1114P-US  
G6B-1174P-FD-US  
Number of Relays: 10 pcs  
Test: the variation of operating voltage is measured  
based on cold start at 23°C, during which rated  
voltage is applied to the coil with rated  
contact current (5A), and left for 1  
hour each under different  
Sample: G6B-1174P-US  
Test: the variation of operating voltage is measured  
based on cold start at 23°C, during which rated  
voltage is applied to the coil with rated contact  
current (8A), and left for 1 hour  
G
6
B
30  
20  
10  
0
30  
each under different ambient  
20 temperatures.  
20  
10  
0
ambient  
temperatures.  
120% applied  
110% applied  
120% applied  
110% applied  
100% applied  
10  
0
120% applied  
110% applied  
100% applied  
100% applied  
10  
10  
20  
10  
20  
20  
50  
40 20  
0
20  
40  
60  
80 100  
50  
40 20  
0
20  
40  
60  
80 100  
50  
40 20  
0
20  
40  
60  
80 100  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Dimensions  
1-pole Single-side Stable Models  
G6B-1114P(-FD)-US  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
2.54  
Four, 1.1-dia. holes  
10 max.  
(9.8)*  
2.54  
10 max.  
(9.8)* 0.3  
(1.2)  
1
3
4
6
3.5  
0.85 0.9  
Note: Check carefully  
the coil polarity of the  
Relay.  
0.5  
0.9  
20 max.  
(19.9)*  
10.16  
7.62  
0.5  
(1.1)  
* Average value  
Note: Orientation marks are indicated as follows:  
1-pole Single-side Stable Models  
G6B-1174P(-FD)-US  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
2.54  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Four, 1.1-dia. holes  
10 max.  
(9.9)*  
2.54  
(1.2)  
12.5 max.  
(12.45)* 0.65  
1
6
3
4
3.5  
0.85 0.9  
Note: Check carefully  
the coil polarity of the  
Relay.  
0.5  
0.9  
20.2 max.  
(20.0)*  
10.16  
7.62  
0.45  
(1.2)  
* Average value  
Note: Orientation marks are indicated as follows:  
6
G6B  
PCB Power Relay  
1-pole Single-winding Latching Model  
G6BU-1114P-US  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
2.54  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
Four, 1.1-dia. holes  
10 max.  
(9.8)*  
2.54  
(1.2)  
10 max.  
(9.8)* 0.3  
1
6
3
4
S
R
3.5  
Note: Check carefully  
the coil polarity of the  
Relay.  
0.85 0.9  
0.5  
0.9  
20 max.  
(19.9)*  
10.16  
7.62  
* Average value  
0.5  
(1.1)  
S: Set coil  
R: Reset coil  
Note: Orientation marks are indicated as follows:  
1-pole Double-winding Latching Model  
G6BK-1114P-US  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
2.54  
Six, 1.1-dia. holes  
10 max.  
(9.8)*  
2.54  
(1.2)  
1
6
2
5
10 max.  
(9.8)* 0.3  
3
R
4
S
3.5  
Note: Check carefully  
the coil polarity of the  
Relay.  
0.85  
0.5  
* Average value  
0.9  
0.85  
0.9  
20 max.  
(19.9)*  
2.54  
7.62  
7.62  
0.5  
G
6
B
(1.1)  
S: Set coil  
R: Reset coil  
Note: Orientation marks are indicated as follows:  
1-pole Single-side stable Models SPST-NO (1a) (Built-in high capacity operation  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
indicator & surge absorption diode)  
20.2 max.  
0.45  
G6B-1177P(-FD)-ND-US  
(20)*  
3.7  
1.7  
Four, 1.1-dia. holes  
10 max.  
(9.9)*  
2.54  
1
6
3
4
LED  
1.6  
2.54  
0.3  
7.62  
(1.2)  
Note: Check carefully the  
coil polarity of the Relay.  
15 max.  
(14.8)*  
(1.11)  
10.16  
7.62  
0.65  
Note: The G6B-1177P-ND-US model has a  
flux-resistant construction. Do not wash it down  
with water. Pay attention to the polarity of the  
coil since the LED and surge absorption diode  
are built-in.  
3.5  
0.85 0.9  
10.16  
0.9  
0.5  
7.62  
7.62  
* Average value  
2-poles Single-side stable Models (SPST-NO (1a) + SPST-NC (1b),  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±0.1 mm  
Terminal Arrangement/  
Internal Connections  
(BOTTOM VIEW)  
20 max.  
DPST-NC (2c), SPST-NO(1a))  
(19.9)*  
G6B-2114P-US  
G6B-2214P-US  
G6B-2014P-US  
11 max.  
(10.9)*  
Six, 1.1-dia. holes  
2.54  
G6B-2114P-US  
1
3
4
2.54  
7.62  
(1.7)  
8
6
5
11 max.  
(10.9)*  
(1.11)  
10.16  
7.62  
G6B-2014P-US  
3.5  
1
3
4
0.8  
0.3  
10.16  
7.62  
7.62  
8
6
5
* Average value  
G6B-2214P-US  
1
3
4
8
6
5
Note: Check carefully  
the coil polarity of the  
Relay.  
7
G6B  
Connecting Sockets Dimensions  
PCB Power Relay  
Socket for 1-pole Single-winding Latching Model and  
Single-side Stable Model  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±±01 mm  
23.2 max.  
P6B-04P  
(23)*  
Four, 1.1-dia. holes  
10 max.  
(9.9)*  
2.54  
3
2.54  
2.54  
2.54  
(1.2)  
10.1 max.  
(10)*  
7
(2.71)  
10.16  
7.62  
3.5  
0.8  
0.4  
10.16  
7.62  
7.62  
* Average value  
Socket for 1-pole Double-winding Latching Model  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±±01 mm  
P6B-06P  
23.2 max.  
(23)*  
10 max.  
(9.9)*  
3
Six, 1.1-dia. holes  
2.54  
G
6
B
(1.2)  
10.1 max.  
(10)*  
7
3.5  
(2.71)  
7.62  
7.62  
0.8  
2.54  
0.4  
2.54  
7.62  
7.62  
7.62  
* Average value  
Socket for Double-pole Single-side Stable  
P6B-26P  
PCB Mounting Holes  
(BOTTOM VIEW)  
Tolerance: ±±01 mm  
23.2 max.  
(23)*  
11 max.  
(10.8)*  
3.1  
Six, 1.1-dia. holes  
2.54  
10.1 max.  
(10)*  
(1.6)  
7
3.5  
(2.61)  
10.16  
7.62  
0.8  
0.4  
10.16  
7.62  
7.62  
* Average value  
Removal Tool  
Hold-down Clips  
Related Products  
P6B-Y1  
P6B-C2  
The G6B-4 Terminal Relay series with  
4-point output is also available0  
For details, contact your OMRON sales  
representative0  
8
G6B  
Approved Standards  
PCB Power Relay  
• The approval rating values for overseas standards are different from the performance values determined individually0 Confirm the  
values before use0  
UL Recognized:  
(File No0 E41643)  
Contact  
Coil  
ratings  
Number of test  
operations  
Model  
Contact ratings  
form  
1
5 A, 25± VAC (General Use) at 8±°C  
5A, 3± VDC at 8±°C  
6,±±±  
1,±±±  
G6B-1114P-US  
G6B-1114P-FD-US  
3 to 24  
VDC  
1/8HP, 25± VAC at 8±°C  
1/6HP, 25± VAC at 8±°C  
8 A, 25± VAC (General Use) at 8±°C  
8 A, 3± VDC at 8±°C  
G6B-1174P-US  
G6B-1174P-FD-US  
3 to 24  
VDC  
1
2
6,±±±  
G6B-2114P(-FD)-US  
G6B-2214P(-FD)-US  
G6B-2±14P(-FD)-US  
5 A, 25± VAC (General Use) at 4±°C  
3 to 48  
VDC  
5 A, 3± VDC at 4±°C  
CSA Certified:  
(File No0 LR31928)  
Contact  
form  
Coil  
ratings  
Number of test  
operations  
Model  
Contact ratings  
5 A, 25± VAC (General Use) at 8±°C  
5A, 3± VDC at 8±°C  
6,±±±  
1,±±±  
G6B-1114P-US  
G6B-1114P-FD-US  
3 to 24  
VDC  
1
1/6HP, 25± VAC at 8±°C  
G
6
B
36±WT, 12± VAC at tungsten 8±°C  
8 A, 25± VAC (General Use) at 8±°C  
8 A, 3± VDC at 8±°C  
G6B-1174P-US  
G6B-1174P-FD-US  
3 to 24  
VDC  
1
2
6,±±±  
G6B-2114P(-FD)-US  
G6B-2214P(-FD)-US  
G6B-2±14P(-FD)-US  
5 A, 25± VAC (General Use) at 4±°C  
3 to 48  
VDC  
5 A, 3± VDC at 4±°C  
EN/IEC, TÜV Certified: (Registration No0 R5±158246)  
Contact  
form  
Coil  
ratings  
Number of test  
operations  
Model  
Contact ratings  
5 A, 25± VAC (cosφ = 1) at 7±°C  
2 A, 25± VAC (cosφ = ±04) at 7±°C  
5 A, 3± VDC (L/R = ± ms) at 7±°C  
8 A, 25± VAC (cosφ = 1) at 7±°C  
2 A, 25± VAC (cosφ = ±04) at 7±°C  
8 A, 3± VDC (L/R = ± ms) at 7±°C  
5 A, 25± VAC (cosφ = 1) at 7±°C  
105 A, 25± VAC (cosφ = ±04) at 7±°C  
5 A, 3± VDC (L/R = ± ms) at 7±°C  
3 to 48  
VDC  
G6B-1114P-US  
1
1
2
3 to 48  
VDC  
G6B-1174P-US  
2±,±±±  
G6B-2114P-US  
G6B-2214P-US  
G6B-2±14P-US  
3 to 48  
VDC  
9
G6B  
Precautions  
PCB Power Relay  
Please refer to “PCB Relays Common Precautions” for correct use.  
Correct Use  
Mounting  
Inhibit Circuit of the  
Other precautions  
G6B-1177P(-FD)-ND-US Model  
• When installing more than two Relays  
side by side on a PCB, keep the gaps  
as shown below0  
• The P6B model has a flux-resistant  
construction0 Do not wash it down with  
water0  
• Do not use under conditions in which a  
surge is included in the power supply,  
such as when an inductive load is  
It may cause a malfunction if heat is  
not dissipated smoothly from the  
Relay0  
• Perform wiring of No01 and No0 2 of the  
X terminal as COM for double-winding  
latching as shown below0 The  
operation stability improves by doing  
this0  
connected in parallel to the coil0 Doing  
so will cause damage to the installed  
(or built-in) coil surge absorbing diode0  
Pitch:  
2.54 mm × 2 min.  
between terminals  
Coil surge  
absorption  
diode  
Inductive  
load  
G6B  
Coil  
L
6
5
R
2
Pitch: 2.54 mm × 2 min.  
between terminals  
S
• No specified mounting direction0  
1
Using SPDT contact of the  
SPST-NO+SPST-NC Relay  
Mounting Height of Sockets and  
COM  
Precautions  
• Check carefully the coil polarity (+ and -)  
of the Relay G6B-1177P(-FD)-ND-US0  
Do not reverse the polarity when  
connecting0 Otherwise the built-in coil  
surge absorption diode may be  
damaged0  
• Do not construct a circuit so that  
overcurrent and burning occur if the  
NO, NC and SPDT contacts are  
short-circuited with the  
G
6
B
* 19.5 mm max. for  
*17 mm max.  
G6B-1174P-FD-US,  
G6B-1174P-US models  
7 mm max.  
and 22 mm max. for  
G6B-1177P-FD-ND-US,  
G6B-1177P-ND-US models.  
SPST-NO+SPST-NC Relay0Arcing  
may generate short-circuiting between  
contacts if there is short-circuiting  
because of conversion to the MBB  
contact caused by asynchronous  
operation of the NO and NC contacts,  
the interval between the NO and NC  
contacts is small, or a large current is  
left open0  
• Hold-down clips (for mounting and  
removal) are also available0(For P6B-  
C2 model) However, it is not suitable  
for G6B-1174P and G6B-1177P  
models0  
• This Relay is a Power Relay which is  
suitable for power load switching0 Do  
not use the G6B for signal purposes  
such as micro load switching under  
1±± mA0  
• Removal tool is also available0  
(For P6B-Y1 model) However, it is not  
suitable for G6B-1177P model0  
Application examples provided in this document are for reference only0 In actual applications, confirm equipment functions and safety before using the product0  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly0 Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms0  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. K021-E1-11  
±714(±2±7)(O)  
10  

相关型号:

G6BK-1114P-US-6VDC

Power/Signal Relay, SPST, Latched, 0.047A (Coil), 6VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-US-DC12

Power/Signal Relay, SPST, Latched, 0.023A (Coil), 12VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-US-DC24

Power/Signal Relay, SPST, Latched, 0.012A (Coil), 24VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-US-DC5

Power/Signal Relay, SPST, Latched, 0.056A (Coil), 5VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-US-DC6

Power/Signal Relay, SPST, Latched, 0.047A (Coil), 6VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-US-P6BDC5

Power/Signal Relay,
OMRON

G6BK-1114P-US-U

Power/Signal Relay
OMRON

G6BK-1114P-US-UDC5

Power/Signal Relay
OMRON

G6BK-1114P-USDC12

Power/Signal Relay, SPST, Latched, 0.023A (Coil), 12VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-USDC24

Power/Signal Relay, SPST, Latched, 0.012A (Coil), 24VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114P-USDC5

Power/Signal Relay, SPST, Latched, 0.056A (Coil), 5VDC (Coil), 280mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G6BK-1114PUS12VDC

Sub-miniature Relay that Switches up to 5 A
ETC