G5LE-14-12VDC [OMRON]
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.033A (COIL), 12VDC (COIL), 400mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT;型号: | G5LE-14-12VDC |
厂家: | OMRON ELECTRONICS LLC |
描述: | POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.033A (COIL), 12VDC (COIL), 400mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT 光电二极管 继电器 |
文件: | 总4页 (文件大小:857K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
New G5LE
PCB Relay
A Cubic, Single-pole 10-A Power Relay
Subminiature “sugar cube” relay with universal
terminal footprint.
Conforms to VDE0435 (VDE approval: B250
Insulation grade), UL508, CSA22.2.
Tracking resistance: CTI>250 (-VD type).
UL class-F coil insulation model available (UL
class-B coil insulation for standard model).
High switching power: 10 A.
Two types of seal available; flux protection and fully
sealed.
Withstands impulse of up to 4,500 V.
RCE
VDE
X
400-mW and 360-mW coil power consumption
types available.
Pre-soldered terminals.
Ordering Information
Contact material
AgSnIn
Enclosure ratings
Contact form
AgSnO
AgCdO
2
Flux protection
SPDT
G5LE-1
G5LE-1-VD
G5LE-1-ASI
G5LE-1-ASI-VD
G5LE-1-ACD
G5LE-1-ACD-VD
G5LE-1-CF
G5LE-1-ASI-CF
G5LE-1-ACD-CF
SPST-NO
SPDT
G5LE-1A
G5LE-1A-VD
G5LE-1A-CF
G5LE-1A-ASI
G5LE-1A-ASI-VD
G5LE-1A-ASI-CF
G5LE-1A-ACD
G5LE-1A-ACD-VD
G5LE-1A-ACD-CF
Fully sealed
G5LE-14
G5LE-14-VD
G5LE-14-ASI
G5LE-14-ASI-VD
G5LE-14-ACD
G5LE-14-ACD-VD
G5LE-14-CF
G5LE-14-ASI-CF
G5LE-14-ACD-CF
SPST-NO
G5LE-1A4
G5LE-1A4-VD
G5LE-1A4-ASI
G5LE-1A4-ASI-VD
G5LE-1A4-ACD
G5LE-1A4-ACD-VD
G5LE-1A4-CF
G5LE-1A4-ASI-CF
G5LE-1A4-ACD-CF
Note: When ordering, add the rated coil voltage to the model number.
Example: G5LE-1 12 VDC
Rated coil voltage
Model Number Legend
G5LE -
-
-
-
-
VDC
1 2
3
4
5
6
7
8
1. Number of Poles
1: 1 pole
5. Insulation System
None: Class B
CF:
Class F (UL and CSA only)
2. Contact Form
None: SPDT
6. Coil Power Consumption/Coil Characteristic
A:
3. Enclosure Ratings
None: Flux protection
4: Fully sealed
4. Contact Material
None: AgSnO
SPST-NO
None: Approx. 400 mW
36:
Approx. 360 mW
7. Approved Standards
None: UL, CSA, TÜV
VD: UL, CSA, TÜV and VDE
(Not applicable with “-CF.”)
2
ASI: AgSnIn
ACD: AgCdO
8. Rated Coil Voltage
5, 9, 12, 24, 48 VDC
1
New G5LE
New G5LE
Specifications
Coil Ratings
400-mW Type
Rated voltage
5 VDC
79.4 mA
63 !
9 VDC
45 mA
200 !
12 VDC
33.3 mA
360 !
24 VDC
16.7 mA
1,440 !
48 VDC
8.33 mA
5,760 !
Rated current
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
75% max. of rated voltage
10% min. of rated voltage
130% of rated voltage at 85"C, 170% of rated voltage at 23"C
Power consumption
Approx. 400 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23"C with a tolerance of #10%.
360-mW Type
Rated voltage
5 VDC
72 mA
70 !
9 VDC
40 mA
225 !
12 VDC
30 mA
400 !
24 VDC
15 mA
48 VDC
7.5 mA
6,400 !
Rated current
Coil resistance
1,600 !
Must operate voltage
Must release voltage
Max. voltage
75% max. of rated voltage
10% min. of rated voltage
130% of rated voltage at 85"C, 170% of rated voltage at 23"C
Power consumption
Approx. 360 mW
Note: The rated current and coil resistance are measured at a coil temperature of 23"C with a tolerance of #10%.
Contact Ratings
Load
Resistive load (cos$ = 1)
Rated load
10 A at 120 VAC; 8 A at 30 VDC
Rated carry current
Max. switching voltage
Max. switching current
Max. switching power
Min. permissible load
10 A
250 VAC, 125 VDC (30 VDC when UL/CSA standard is applied)
AC: 10 A; DC: 8 A
1,200 VA, 240 W
100 mA at 5 VDC
Characteristics
Contact resistance
100 m! max.
10 ms max.
5 ms max.
Operate time
Release time
Bounce time
Operate: Approx. 0.6 ms
Release: Approx. 7.2 ms
Max. switching frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr at rated load
Insulation resistance
Dielectric strength
100 M! min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
Vibration resistance
4,500 V (1.2×50 %s) between coil and contacts
Destruction: 10 to 55 Hz, 1.5-mm double amplitude
Malfunction:10 to 55 Hz, 1.5-mm double amplitude
2
Shock resistance
Life expectancy
Destruction: 1,000 m/s
Malfunction: 100 m/s
2
Mechanical:10,000,000 operations min. (at 18,000 operations/hr)
Electrical: 100,000 operations min. (at 1,800 operations/hr)
Ambient temperature
Operating: --40"C to 85"C (with no icing)
Storage:
--40"C to 85"C (with no icing)
Ambient humidity
Weight
Operating: 35% to 85%
Approx. 12 g
2
New G5LE
New G5LE
Approved Standards
UL508, UL114, UL478, UL325, UL873, UL1409, UL1950 (File No. E41643)/CSA C22.2 No. 14, No. 1
(File No. LR34815)
Model
Coil rating
3 to 48 VDC
Contact rating
G5LE
12 A, 120 VAC (resistive load 30,000 cycles)
10 A, 250 VAC (general use)
10 A, 125 VAC (general use 100,000 cycles)
8 A, 30 VDC (resistive load)
6 A, 277 VAC (general use)
NO:
1/6 hp, 120 VAC (50,000 cycles)
1/3 hp, 125 VAC, 70"C 30K with Class 130B system
65"C 30K with Class 105 Coil insulation system
TV-3, 120 VAC
TV-5, 120 VAC (For ASI only)
NC:
1/8 hp, 120 VAC (50,000 cycles)
1/10 hp, 120 VAC (50,000 cycles)
TÜV DIN VDE 0435, IEC 255 (File No. R9151267)
Model
Coil rating
Contact rating
G5LE
Approx. 400 mW
3, 5, 6, 9, 12, 24 VDC
Approx. 360 mW
2.5 A, 250 VAC (cos$ = 0.4)
5 A, 250 VAC (resistive load)
8 A, 30 VDC (resistive load)
5, 6, 9, 12, 24 VDC
VDE DIN VDE 0435, DIN EN 60255 (File No. 6850ÜG)
Model
Coil rating
Contact rating
G5LE
Approx. 400 mW
3, 5, 6, 9, 12, 24, 48 VDC
Approx. 360 mW
5 A, 250 VAC (resistive load, 50,000 cycles)
at 85"C.
5, 6, 12, 24, 48 VDC
Engineering Data
Maximum Switching Power
G5LE
Life Expectancy
G5LE
5,000
Ambient Temperature vs.
Maximum Coil Voltage
10
200
AC re-
sistive
load
7
3,000
5
180
3
1,000
700
500
30-VDC
resistive load
120-VAC
resistive load
160
140
DC resistive
load
300
1
0.7
0.5
100
70
50
120
100
0
30-VDC
inductive
(L/R=7 ms)
0.3
120-VAC
inductive
cos$=0.4
(see note)
30
0
0
2
4
6
8
10
12
--25 20 2330 40 50 60 70 80 90 100
0
10
30 50
125 250 500 1,000
Switching current (A)
Ambient temperature ("C)
Switching voltage (V)
Note: The maximum coil voltage refers to the
maximum value in a varying range of
operating power voltage, not a continu-
ous voltage.
Note: Same curve as for 250-VAC
resistive load
3
New G5LE
New G5LE
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Orientation marks are indicated as follows:
G5LE-1
G5LE-1A
Terminal
Arrangement/Internal
Connections (Bottom View)
Mounting Holes
(Bottom View)
Tolerance: #0.1 mm
unless specified
Five, 1.3+0.2dia. holes
SPDT
SPDT
0
(2.25)
3
4
2
5
12
1
22.5 max.
(21.6)*
16.5 max.
(15.6)*
(2.25)
(2.55)
12.2
2
(5.75)
19.0 max.
(18.5)*
0.5
3.5
0.2
1
1.2
0.4
*Average value
G5LE-14
G5LE-1A4
Terminal
Mounting Holes
(Bottom View)
Tolerance: #0.1 mm
unless specified
Arrangement/Internal
Connections (Bottom View)
Four, 1.3+0.2 dia. holes
SPST-NO
SPST-NO
0
(2.25)
3
2
12
(2.25)
1
16.5 max.
(15.6)*
22.5 max.
(21.6)*
5
(2.55)
12.2
2
(5.75)
19.0 max.
(18.5)*
0.5
3.5
0.2
1
1.2
0.4
*Average value
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. K100-E1-2A
4
相关型号:
G5LE-14-24VDC
POWER/SIGNAL RELAY, SPDT, MOMENTARY, 0.017A (COIL), 24VDC (COIL), 400mW (COIL), 8A (CONTACT), 30VDC (CONTACT), THROUGH HOLE-STRAIGHT MOUNT, ROHS COMPLIANT
OMRON