G5CA-1A-TP-E-DC5 [OMRON]
Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount, ROHS COMPLIANT;型号: | G5CA-1A-TP-E-DC5 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount, ROHS COMPLIANT 继电器 |
文件: | 总6页 (文件大小:260K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
GPCB5ReClayA
Flat Relays that Switch 10-A/15-A Loads
with New Quick-connect Terminals
• Ideal for switching power in household appliances or for
outputs from industrial devices.
• Subminiature dimensions: 16 x 22 x 11 mm (L x W x H).
• High-sensitivity models available with low power
consumption (150 mW).
• UL recognized / CSA certified.
• Fully sealed models and quick-connect terminal models
available (#187 load contact terminals).
• RoHS Compliant.
Ordering Information
To order: Select the part number and add the rated coil voltage to the part number. Example: G5CA-1A4-H DC12.
Item
Contact
configuration
Model
High-capacity
Enclosure
Ratings
Standard
High-sensitivity
Quick-connect terminals
(#187)
Flux protection SPST-NO
Fully sealed
G5CA-1A
G5CA-1A-H
G5CA-1A-E
G5CA-1A-TP-E
G5CA-1A4
G5CA-1A4-H
---
---
Note: 1. Contact your OMRON representative for details on other coil voltage specifications.
2. High-capacity models with a fully sealed structure are not available.
3. Standard or high-sensitivity models with quick-connect terminals are not available.
■ Model Number Legend
G5CA-1A
-
-
-
1
2
3 4
5
Standard Specifications
1. Number of Poles
2. Enclosure Ratings
4. Special functions
None: Flux protection
1A: 1 pole (SPST-NO)
None: Standard
Contact Configuration:SPST-NO
4:
Fully sealed
E:
High-capacity
Enclosure Ratings: Flux protection
5. Coil consumption
3. Terminal form
None: Standard
Terminal form:
PCB terminal
None: PCB terminal
H:
High-sensitivity
TP: Quick-connect terminal (#187)
PCB Relay G5CA
203
Specifications
■ Coil Ratings
Item
Standard, high-capacity, or quick-connect terminals High-sensitivity
5 VDC
40 mA
125 Ω
12 VDC
16.7 mA
720 Ω
24 VDC
8.3 mA
2,880 Ω
5 VDC
30 mA
167 Ω
12 VDC
12.5 mA
960 Ω
24 VDC
6.25 mA
3,840 Ω
Rated current
Coil resistance
Must-operate voltage
Must-release voltage
Max. voltage
75% of rated voltage (max.)
10% of rated voltage (min.)
80% of rated voltage (max.)
150% (standard)/130% (high-capacity, quick-connect
terminals) of rated voltage (at 23°C)
150% of rated voltage at 23°C
Power consumption
Approx. 200 mW
Approx. 150 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The "maximum voltage" is the maximum voltage that can be applied to the relay coil.
■ Contact Ratings
Item
Standard
High-sensitivity
Resistive load
High-capacity, or quick-connect
terminals
Resistive load
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
Resistive load
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
Contact form
Contact material
Rated load
Single
Silver alloy
10 A at 250 VAC; 3 A at 250 VAC;
10 A at 30 VDC
10 A at 250 VAC; 3 A at 250 VAC;
15 A at 110 VAC; 5 A at 110 VAC;
3 A at 30 VDC
10 A at 30 VDC
3 A at 30 VDC
10 A at 30 VDC
3 A at 30 VDC
Rated carry current
10 A
10 A
15 A
Max. switching voltage 250 VAC, 125 VDC
Max. switching current 10 A
10 A
15 A
Max. switching power
(reference value)
2,500 VA, 300 W 750 VA, 90 W
2,500 VA, 300 W 750 VA, 90 W
2,500 VA, 300 W 750 VA, 90 W
204
PCB Relay G5CA
■ Characteristics
Contact resistance (see note 2)
Operate time (see note 3)
Release time
30 mΩ max. (quick-connect terminals type: 100 mΩ max.)
10 ms max. (15 ms max.)
10 ms max.
Insulation resistance (see note 4) 1,000 MΩ min. (at 500 VDC)
Dielectric strength
2,500 VAC, 50/60 Hz for 1 min. between coil and contacts
1,000 VAC, 50/60 Hz for 1 min. between contacts of same polarity
Impulse withstand voltage
Vibration resistance
4,500 V (1.2 x 50 μs)
Destruction:
Malfunction:
10 to 55Hz, 1.5-mm double amplitude
10 to 55 Hz, 1.5-mm double amplitude
1,000 m/s2 (Approx. 100 G)
Shock resistance
Life expectancy
Destruction:
Malfunction:
200 m/s2 (Approx. 20 G)
Mechanical:
Electrical:
20,000,000 operations min. at 18,000 operations/hr
• 300,000 operations min. (100,000 operations min. for Fully sealed Type)
at 1,200 operations/hr under resistive load of 10 A at 250 VAC;
• 100,000 operations min. under resistive load of 15 A at 110 VAC for high-capacity models
• 100,000 operations min. at 1,200 operations/hr under resistive load of 10 A at 30 VDC
Minimum permissible load
(reference value: see note 5)
5 VDC, 100 mA
Ambient temperature
Ambient humidity
Weight
Operating: -25°C to 70°C (with no icing or condensation)
Operating: 5% to 85%
Approx. 8 g (for TP model: Approx. 9.6 g)
Note: 1. The data shown above are initial values.
2. Measurement conditions: 5 VDC, 1 A, voltage drop method.
3. Measurement conditions: The value in parentheses indicates the operate time for high-sensitivity types.
4. Measurement conditions: Measured at the same points as the dielectric strength using a 500-VDC ohmmeter.
5. This value is for a switching frequency of 120 operations/minute. (P level: λ60 = 0.1 x 10-5 operations)
■ Approved Standards
• The following UL-, CSA-, and EN/TÜV-certifying ratings differ from the performance characteristics of the individual models.
UL Recognized
(File No. E41515) - - Ambient Temp. = 40°C
EN Standard/TÜV Certificated:
EN61810-1 (Certification No. R50030053)
Model
No. of
poles
Coil
Contact rating
No. of
Model
No. of
poles
Coil
Contact rating
No. of
rating
operations
rating
operations
G5CA
1
3, 5, 6,
12, 24, 48 (cosφ = 1.0)
VDC
15 A, 125 VAC
100,000
G5CA
1
5 to
15 A, 125 VAC
100,000
100 VDC (General purpose)
10 A, 250 VAC
15 A, 250 VAC
(General purpose)
10 A, 30 VDC
(Resistive)
(cosφ = 1.0)
10 A, 30 VDC
L
(– = 0 ms)
R
CSA Certified
(File No. LR31928)
Model
G5CA
No. of
poles
Coil
Contact rating
No. of
rating
operations
1
5 to
15 A, 125 VAC
100,000
100 VDC (General purpose)
10 A, 250 VAC
(General purpose)
10 A, 30 VDC
(Resistive)
PCB Relay G5CA
205
Engineering Data
Maximum Switching Capacity
Electrical Service Life
Ambient Temperature vs.
Maximum Coil Voltage
200
500
300
50
AC resistive load
G5CA-1A-E
AC inductive
load
G5CA-1A-E
(cos φ=0.4)
AC resistive load
G5CA-1A
30
180
15
250-VAC resistive load
100
70
50
10
7
5
Continuous max.
permissile voltage (10 A)
160
150
140
130
120
110-VAC resistive load
30
3
DC resistive load
G5CA-1A
G5CA-1A-E
1
0.7
0.5
10
7
5
30-VDC resistive load
Continuous max.
permissile voltage (15 A)
100
DC inductive load
G5CA-1A
G5CA-1A-E
(L/R=7 ms)
AC inductive
load
G5CA-1A
(cos φ=0.4)
0.3
3
1
80
60
0.1
1
3
5
7 10
30 50 100
300 500 1,000
0
20
30
40
50
60
70
80 90
0
2
4
6
8
10
12
14 16
Switching voltage (V)
Switching current (A)
Ambient temperature (˚C)
Operating Temperature vs.
Malfunction Shock
Must-operate/Must-release Voltage
100
Sample: G5CA-1A DC
Y
Unit: m/s2
1,000 min.
No. of samples: 5
Must-operate voltage
Must-release voltage
800
600
400
200
80
1,000 min.
X
1,000 min.
Z
max.
X
60
No. of samples: 10
min.
Measured value: The value at which
malfunction occurs
in the contact when
the contact is
200
400
600
800
40
max.
X
X'
Z'
subjected to shock
three times each in
six directions for
1,000 min.
min.
1,000 min.
20
Shock direction
X
X'
1,000 min.
Y
three axes.
Y'
0
−40
Z
200 m/s2
−20
0
20
40
60
80
Standard:
Z'
Ambient temperature (˚C)
Y'
Note: The "maximum voltage" is the maximum
voltage that can be applied to the relay coil,
but, not continously.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Mounting Holes (PCB)
(BOTTOM VIEW)
Tolerance: ±±0. ꢀꢀ
2054
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
G5CA-1A(-E)
G5CA-1A4(-H)
Two, . dia0 hole
22 ꢀax0
(2.09)*
.6 ꢀax0
(.509)*
2054
.. ꢀax0
(.±09)*
.
2
.207
305
4
3
±03
±04
.06
±06
.207
.±0.6
7062
(No coil polarity)
2
Two, . dia0
elliptic holes
* Average value
Note: Orientation ꢀarks are
.±0.6
.7078
indicated as follows:
206
PCB Relay G5CA
Mounting Holes
(BOTTOM VIEW)
Tolerance: ±±0. ꢀꢀ
Terminal Arrangement/
Internal Connections
(BOTTOM VIEW)
Four, .02 dia0
G5CA-1A-TP-E
250.ꢀax0
(2409)*
220.ꢀax0
(2.09)*
.08
Two, . dia0
elliptic holes
4
408
±05
.03 dia0
6035
.±˚±.˚
.
3
302
.4025
6025
.303
409
..
(.±09)*
.7078
(TOP VIEW)
2
306
±03
.035
* Average value
±03
±05
.4025
.
.06
.60.
2.0.
5
±06
.60.
5
(BOTTOM VIEW)
.7078
(No coil polarity)
Precautions
■ Precautions for Correct Use
Installation
Charged Terminals
Make sure that sufficient space is provided between relays when
installing two or more relays side by side to facilitate heat dissipation.
Insufficient heat dissipation may result in the relay malfunctioning.
.
The section marked with dotted circles (indicated by arrows) in the
following diagram includes the charged terminals of the relay. When
the relay is mounted on a PCB, make sure that there are no metal
patterns on the section of the PCB facing the portion of the relay
shaded in the following diagram.
.
Pitch:
2054 ꢀꢀ × 4 ꢀin0
between terꢀinals
Charged
terꢀinals
.207
Pitch: 2054 ꢀꢀ × 3 ꢀin0 between terꢀinals
8
605
±0.8
Quick-connect Terminal Connections
Other Precautions
• Do not pass current through the PCB of the load contact terminals
(quick-connect terminals).
• The terminals are compatible with Faston receptacle #187 and are
suitable for positive-lock mounting.
Use only Faston terminals with the specified numbers. Select leads
for connecting Faston receptacles with wire diameters that are
within the allowable range for the load current. Do not apply exces-
sive force to the terminals when mounting or dismounting the Fas-
ton receptacle.
• The G5CA is a power relay designed for applications switching
power loads such as heaters in electric household appliances. Do
not use the G5CA to switch micro loads less than 100 mA, such as
in signal applications.
• Use fully sealed models if the relays will require washing. Flux-pro-
tection models may malfunction or the relay's performance may be
otherwise adversely affected if cleaning fluid enters the relay.
Insert and remove terminals carefully one at a time. Do not insert
terminals on an angle, or insert/remove multiple terminals at the
same time.
The following positive-lock connectors made by AMP are recom-
mended. Contact the manufacturer directly for details on connec-
tors including availability.
.
Type
Receptacle terminals Positive housing
(see note)
#187 terminals AMP 170330-1
(width: 4.75 mm) (170324-1)
AMP 172074-1 (natural
color)
AMP 170331-1
(170325-1)
AMP 170332-1
(170326-1)
AMP 172074-4 (yellow)
AMP 172074-5 (green)
AMP 172074-6 (blue)
Note: The numbers shown in parentheses are for air-feeding.
PCB Relay G5CA
207
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
PCB Relay G5CA
相关型号:
G5CA-1A-TP-EDC5
Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 15A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Panel Mount, ROHS COMPLIANT
OMRON
G5CA-1A4-DC12
Power/Signal Relay, SPST, Momentary, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5CA-1A4-DC5
Power/Signal Relay, SPST, Momentary, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
G5CA-1A4-H-DC24
Power/Signal Relay, SPST, Momentary, 0.006A (Coil), 24VDC (Coil), 150mW (Coil), 10A (Contact), 125VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON
©2020 ICPDF网 联系我们和版权申明