G3VM-351H(TR) [OMRON]

Transistor Output SSR, 1-Channel, 1500V Isolation, ROHS COMPLIANT, MINIATURE, SOP-6;
G3VM-351H(TR)
型号: G3VM-351H(TR)
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Transistor Output SSR, 1-Channel, 1500V Isolation, ROHS COMPLIANT, MINIATURE, SOP-6

输出元件 光电
文件: 总3页 (文件大小:367K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
G3VM-351H  
MOS FET Relays  
MOS FET Relays Designed for Switching  
Minute Signals and Analog Signals.  
Upgraded G3VM-S3 Series.  
Continuous load current of 110 mA.  
RoHS compliant  
Note: The actual product is marked differently from the  
image shown here.  
Application Examples  
Terminal Arrangement/Internal Connections  
6
5
4
Semiconductor test equipment  
Test & Measurement equipment  
Communication equipment  
Data loggers  
OMRON logo  
Pin 1 mark  
Model name  
LOT.No.  
932  
1
2
3
Note: The actual product is marked differently from the image shown here.  
List of Models  
Minimum package quantity  
Model  
Load voltage  
(peak value) *  
Package type Contact form  
Terminals  
Number per tube Number per tape and reel  
G3VM-351H  
75  
-
-
1a  
SOP6  
Surface-mounting Terminals  
350 V  
(SPST-NO)  
G3VM-351H (TR)  
2,500  
* The AC peak and DC value are given for the load voltage.  
Absolute Maximum Ratings (Ta = 25°C)  
Item  
Symbol  
IF  
Rating  
50  
0.5  
5
125  
350  
110  
110  
220  
1.1  
1.1  
2.2  
125  
Unit  
mA  
Measurement conditions  
Note: 1. The dielectric strength between the input and output was  
checked by applying voltage between all pins as a group on  
the LED side and all pins as a group on the light-receiving side.  
LED forward current  
LED forward current reduction rate  
LED reverse voltage  
Connection temperature  
Load voltage (AC peak/DC)  
Connection A  
IF/°C  
VR  
mA/°C Ta 25°C  
Connection Diagram  
V
°C  
V
TJ  
1
2
3
6
5
4
Load  
AC  
DC  
VOFF  
Connection A  
Connection B  
Connection C  
or  
Continuous  
Connection B  
Connection A: AC peak/DC  
Connection B and C: DC  
IO  
mA  
load current  
Connection C  
Connection A  
Connection B  
Connection C  
ON current  
reduction  
rate  
1
2
3
6
5
4
Load  
DC  
IO/°C  
mA/°C Ta 25°C  
°C  
Connection temperature  
Dielectric strength between  
I/O (See note 1.)  
Ambient operating temperature  
Ambient storage temperature  
TJ  
VI-O  
1500  
Vrms  
AC for 1 min  
1
2
3
6
5
4
Load  
DC  
Ta  
Tstg  
40 to +85  
55 to +125  
°C  
°C  
With no icing or condensation  
With no icing or condensation  
Soldering temperature  
-
260  
°C  
10 s  
Electrical Characteristics (Ta = 25°C)  
Item  
Symbol Minimum Typical Maximum Unit  
Measurement conditions  
IF = 10 mA  
LED forward voltage  
Reverse current  
Capacity between terminals  
Trigger LED forward current  
VF  
IR  
1.0  
-
-
-
-
-
-
-
1.15  
-
30  
1
25  
35  
28  
14  
-
30  
0.8  
-
1.3  
10  
-
V
µA  
pF  
mA  
VR = 5 V  
CT  
IFT  
V = 0, f = 1 MHz  
IO = 110 mA  
IF = 5 mA, IO = 110 mA, t < 1 s  
3
Note: 2. Turn-ON and Turn-OFF Times  
35  
50  
40  
20  
1.0  
-
IF  
1
6
RL  
Maximum  
resistance  
with output  
ON  
Connection A  
VDD  
IF = 5 mA, IO = 110 mA  
IF = 5 mA, IO = 110 mA  
IF = 5 mA, IO = 220 mA  
VOFF = 350 V  
V = 0, f = 1 MHz  
f = 1 MHz, Vs = 0 V  
VOUT  
RON  
2
4
Connection B  
Connection C  
Current leakage when the relay is open  
Capacity between terminals  
Capacity between I/O terminals  
Insulation resistance between I/O terminals  
Turn-ON time  
ILEAK  
COFF  
CI-O  
RI-O  
tON  
-
-
µA  
pF  
pF  
MΩ  
ms  
ms  
IF  
-
-
1000  
-
VI-O = 500 VDC, ROH 60 %  
90%  
VOUT  
10%  
-
-
0.3  
0.1  
1.0  
1.0  
IF = 5 mA, RL = 200 ,  
VDD = 20 V (See note 2.)  
tON  
tOFF  
Turn-OFF time  
tOFF  
1
G3VM-351H  
Recommended Operating Conditions  
MOS FET Relays  
Use the G3VM under the following conditions so that the Relay will operate properly.  
Item  
Symbol  
Minimum  
Typical  
Maximum  
Unit  
Load voltage (AC peak/DC)  
Operating LED forward current  
Continuous load current (AC peak/DC)  
Ambient operating temperature  
VDD  
IF  
-
5
-
-
10  
-
280  
25  
100  
65  
V
mA  
mA  
°C  
IO  
Ta  
20  
-
Engineering Data  
LED forward current vs. Ambient  
temperature  
Continuous load current vs. Ambient LED forward current vs. LED forward  
temperature  
voltage  
I
F
- Ta  
I
O
- Ta  
IF  
- VF  
100  
240  
100  
80  
60  
40  
20  
0
Connection C  
Ta = 25°C  
200  
160  
120  
30  
10  
Connection A and B  
3
1
80  
40  
0
0.3  
0.1  
-20  
0
20  
40  
60  
80  
100  
120  
0.6  
0.8  
1
1.2  
1.4  
1.6  
1.8  
-20  
0
20  
40  
60  
80  
100  
120  
Ambient temperature Ta (°C)  
Ambient temperature Ta (°C)  
LED forward voltage V  
F
(V)  
Continuous load current vs. On-state On-state resistance vs. Ambient  
Trigger LED forward current vs.  
Ambient temperature  
voltage  
temperature  
I
O
- VON  
R
ON - Ta  
IFT - Ta  
200  
5
4
3
2
1
0
50  
IO = 120 mA  
IF = 5 mA  
IO = 120 mA  
t < 1s  
Ta = 25°C  
IF = 5 mA  
Connection A  
t < 1s  
40  
Connection A  
100  
0
30  
20  
10  
0
-100  
-200  
-4  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
-3  
-2  
-1  
0
1
2
3
Ambient temperature Ta (°C)  
On-state voltage VON (V)  
Ambient temperature Ta (°C)  
Turn ON, Turn OFF time vs. LED  
forward current  
Turn ON, Turn OFF time vs. Ambient  
temperature  
Current leakage vs. Ambient  
temperature  
t
ON, tOFF - I  
F
t
ON, tOFF - Ta  
ILEAK - Ta  
3000  
1000  
500  
400  
300  
30  
Ta = 25°C  
VDD = 20 V  
RL = 200 Ω  
VDD = 20 V  
RL = 200 Ω  
IF = 5 mA  
VOFF = 350 V  
IF = 5 mA  
tON  
10  
5
300  
100  
200  
100  
tOFF  
30  
10  
tOFF  
t
ON  
1
0.5  
0
1
3
10  
30  
100  
300  
-40  
-20  
0
20  
40  
60  
80  
100  
-40  
-20  
0
20  
40  
60  
80  
100  
LED forward current I  
F
(mA)  
Ambient temperature Ta (°C)  
Ambient temperature Ta (°C)  
Safety Precautions  
Refer to "Common Precautions" for all G3VM models.  
2
Appearance/Dimensions  
SOP6 type  
Appearance  
SOP (Small Outline Packkaage)  
SOP6  
OMRON logo  
Model name  
932  
Pin 1 mark  
LOT.No.  
Note: The actual product is marked differently from the image shown here.  
Dimensions  
(Unit: mm)  
Surface-mounting Terminals  
Actual Mounting Pad  
Dimensions  
Weight: 0.13 g  
0.25  
4.4  
(Recommended Value, TOP VIEW)  
2.1 max.  
0.15  
0.25  
6.3  
6 to 6.3  
1.2  
0.8  
0.3  
0.6  
0.1  
0.1  
0.4  
0.25  
2.54  
2.54 2.54  
0.1  
0.4  
7.0  
Note: The actual product is marked differently from the image shown here.  
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY  
Contact: www.omron.com/ecb  
Cat. No. K166-E1-01  
0412(0412)(O)  

相关型号:

G3VM-351HTR

MOS FET Relays
OMRON

G3VM-351TR

MOS FET Relays
OMRON

G3VM-352C

MOS FET Relays
OMRON

G3VM-352C_10

MOS FET Relays
OMRON

G3VM-352F

MOS FET Relays
OMRON

G3VM-352FTR

MOS FET Relays
OMRON

G3VM-352J

MOSFET RELAYS
OMRON

G3VM-352J(TR)

Transistor Output SSR, 2-Channel, 1500V Isolation, ROHS COMPLIANT, MINIATURE, SOP-8
OMRON

G3VM-352JTR

MOSFET RELAYS
OMRON

G3VM-352J_10

MOS FET Relays
OMRON

G3VM-353

MOS FET Relay with N.C. (Normally Closed) Contacts for Switching Analog Signals.
OMRON

G3VM-353A

MOS FET Relay with N.C. (Normally Closed) Contacts for Switching Analog Signals.
OMRON