G3TC-IAC15AAC/DC240 [OMRON]
Transistor Output SSR, 1-Channel, 4000V Isolation;型号: | G3TC-IAC15AAC/DC240 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Transistor Output SSR, 1-Channel, 4000V Isolation |
文件: | 总12页 (文件大小:1100K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Relays for Industrial I/O
G3TC
Reliable SSRs for I/O Module Mounting
Boards
• Use I/O SSRs as an interface between logic circuitry and the load.
• Variety of AC/DC input and output modules with industry-standard
footprint and color coding.
• Built-in hold down screw fastens relay to board to eliminate loosen-
ing by vabration.
• Optical Isolation - Dielectric strength of 4 kV between input and out-
put terminals.
• Zero cross function on AC output models.
• AC and DC input versions incorporate a rectifier to accept both AC
or DC inputs.
• UL, CSA and TUV approved.
Ordering Information
■ Input Module
Function
Color
Isolation
Input operating
voltage range
Logic level output
supply voltage
Model
AC input
Yellow
Photo-coupler
90-140 VDC/AC
180-280 VDC/AC
10-32 VDC/AC
5 VDC
G3TC-IAC5 AC/DC120
G3TC-IAC15 AC/DC120
G3TC-IAC24 AC/DC120
G3TC-IAC5A AC/DC240
G3TC-IAC15A AC/DC240
G3TC-IAC24A AC/DC240
G3TC-IDC5 DC/AC24
G3TC-IDC15 DC/AC24
G3TC-IDC24 DC/AC24
15 VDC
24 VDC
5 VDC
15 VDC
24 VDC
5 VDC
DC input
White
15 VDC
24 VDC
■ Output Module
Function
Color
Isolation
Photo-triac
Rated input
voltage
Rated output voltage
Model
(Applicable output voltage)
AC output
Black
5 VDC
3 A at 120 VAC
(3 A at 75-140 VAC)
G3TC-OAC5 DC5
15 VDC
24 VDC
5 VDC
G3TC-OAC15 DC15
G3TC-OAC24 DC24
G3TC-OAC5A DC5
G3TC-OAC15A DC15
G3TC-OAC24A DC24
G3TC-ODC5 DC5
3 A at 240 VAC
(3 A at 75-280 VAC)
15 VDC
24 VDC
5 VDC
DC output
Red
Photo-coupler
3 A at 60 VDC
(3 A at 5-60 VDC)
15 VDC
24 VDC
5 VDC
G3TC-ODC15 DC15
G3TC-ODC24 DC24
G3TC-ODC5A DC5
G3TC-ODC15A DC15
G3TC-ODC24A DC24
1 A at 200 VDC
(1 A at 5-200 VDC)
15 VDC
24 VDC
Solid State Relays for Industrial I/O G3TC
419
■ Typical Applications
• HVAC, refrigeration equipment
• Automation controls
• Injection molding machines
• Packaging equipment
■ I/O Classification by Color
Specifications
■ Common Characteristics
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
100 MΩ min at 500 VDC
4000 VAC, 50/60 Hz for 1 minute between input and output
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Malfunction: 1,000 m/s2
Ambient temperature
Operating: -30°C to 80°C with no icing or condensation
Storage: -30°C to 100°C with no icing or condensation
Operating: 45% to 85%
Ambient humidity
Approved standards
UL Recognized, CSA Certified, EN60950
420
Solid State Relays for Industrial I/O G3TC
■ AC Input Module G3TC-IAC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-IAC5
120 VAC/DC
90-140 VAC/DC
90 VAC/DC max.
25 VAC/DC min.
5 mA max.
G3TC-IAC15
G3TC-IAC24
G3TC-IAC5A
240 VAC/DC
180-280 VAC/DC
180 VAC/DC max.
45 VAC/DC min.
5 mA max.
G3TC-IAC15A G3TC-IAC24A
Rated voltage
Operating voltage
Must operate voltage
Must release voltage
Input current at rated voltage
Input resistance (see note 1)
30 kΩ
69 kΩ
Output
Item
G3TC-IAC5
5 VDC
G3TC-IAC15
15 VDC
G3TC-IAC24
24 VDC
G3TC-IAC5A
5 VDC
G3TC-IAC15A G3TC-IAC24A
Output supply voltage-nominal
Output supply voltage-range
15 VDC
24 VDC
4.5-6 VDC
18 mA max.
12-18 VDC
15 mA max.
20-30 VDC
12 mA max.
4.5-6 VDC
18 mA max.
12-18 VDC
15 mA max.
20-30 VDC
12 mA max.
Output supply current at rated
input voltage (see note 2)
Control resistance (Rc in circuit 240 Ω
1 kΩ
2.2 kΩ
240 Ω
1k Ω
2.2k Ω
configuration - see note 1)
Output current
50 mA max.
Characteristics
Item
Operate time (see note 3)
Release time (see note 3)
Output ON voltage drop
Leakage current
G3TC-IAC5
20 ms max.
20 ms max.
0.4 V max.
G3TC-IAC15
G3TC-IAC24
G3TC-IAC5A
G3TC-IAC15A G3TC-IAC24A
100 μA max.
Approx. 40g
Weight
Note: 1. Resistance values are reference.
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
■ DC Input Module G3TC-IDC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-IDC5
24 VDC/AC
G3TC-IDC15
G3TC-IDC24
Rated voltage
Operating voltage
10-32 VDC/ 15-32 VAC
10 VDC/15 VAC max.
3 VDC/ 3 VAC min.
25 mA max.
Must operate voltage
Must release voltage
Input current rated voltage
Input resistance (see note 1)
1.5 kΩ
Output
Item
G3TC-IDC5
5 VDC
G3TC-IDC15
15 VDC
G3TC-IDC24
24 VDC
Output supply voltage-nominal
Output supply voltage-range
4.5-6 VDC
12-18 VDC
15 mA max.
1 kΩ
20-30 VDC
12 mA max.
2.2 kΩ
Output supply current at rated input voltage (see note 2)
18 mA max.
Control resistance (Rc in circuit configuration - see note 1) 240 Ω
Output current 50 mA max.
Solid State Relays for Industrial I/O G3TC
421
Characteristics
Item
G3TC-IDC5
5 ms max.
G3TC-IDC15
G3TC-IDC24
Operate time (see note 3)
Release time (see note 3)
Output ON voltage drop
Leakage current
5 ms max.
0.4 V max.
100 μA max.
Approx. 40g
Weight
Note: 1. Resistance values are reference.
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
■ AC Output Module G3TC-OAC
Ratings (Ambient Temperature 25°C)
Input
Item
Rated voltage
G3TC-OAC5
5 VDC
G3TC-OAC15
15 VDC
G3TC-OAC24
24 VDC
G3TC-OAC5A
5 VDC
G3TC-OAC15A
G3TC-OAC24A
15 VDC
24 VDC
Operating voltage
2.5-8 VDC
9-16 VDC
18-32 VDC
2.5-8 VDC
9-16 VDC
9 VDC max.
18-32 VDC
18 VDC max.
Must operate
voltage
2.5 VDC max.
9 VDC max.
18 VDC max.
2.5 VDC max.
Must release
voltage
1 VDC min.
18 mA max.
Input current at rated
voltage (see note 2)
Control resistance (Rc 240 Ω
in circuit configuration
- see note 1)
1 kΩ
2.2 kΩ
240 Ω
1 kΩ
2.2 kΩ
Output
Item
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-OAC5A
240 VAC
G3TC-OAC15A
G3TC-OAC24A
Rated load voltage
Load voltage range
Load current
120 VAC
75-140 VAC
0.05 to 3 A
75-280 VAC
Inrush current
45 A (60 Hz, 1 cycle)
Characteristics
Item
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
Operate time (see note 3) 1/2 of load power source cycle + 1 ms max.
Release time (see note 3) 1/2 of load power source cycle + 1 ms max.
Output ON voltage drop
Leakage current
Weight
1.6 V (RMS) max.
2.5 mA max. (at 120 VAC)
Approx. 45g
5 mA max. (at 240 VAC)
Note: 1. Resistance values are reference.
2. The output module supplies the current on I/O circuit board at nominal input voltage.
3. At nominal output supply voltage, rated input voltage and 25°C.
422
Solid State Relays for Industrial I/O G3TC
■ DC Output Module G3TC-ODC
Ratings (Ambient Temperature 25°C)
Input
Item
G3TC-ODC5
5 VDC
G3TC-ODC15
15 VDC
G3TC-ODC24
24 VDC
G3TC-ODC5A
5 VDC
G3TC-ODC15A
15 VDC
G3TC-ODC24A
24 VDC
Rated voltage
Operating voltage
2.5-8 VDC
9-16 VDC
18-32 VDC
2.5-8 VDC
9-16 VDC
18-32 VDC
Must operate
voltage
2.5 VDC max.
9 VDC max.
18 VDC max.
2.5 VDC max.
9 VDC max.
18 VDC max.
Must release
voltage
1 VDC min.
Input current at rated 18 mA max.
voltage (see note 2)
Control resistance (Rc 240 Ω
in circuit configuration
- see note 1)
1 kΩ
2.2 kΩ
240 Ω
1 kΩ
2.2 kΩ
Output
Item
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
G3TC-ODC5A
200 VDC
G3TC-ODC15A
G3TC-ODC24A
Rated load voltage
Load voltage range
Load current
60 VDC
5-60 VDC
0.01 to 3 A
18 A (10 ms)
5-200 VDC
0.01 to 1.0 A
9 A (10 ms)
Inrush current
Characteristics
Item
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
G3TC-ODC5A
100 μs max.
750 μs max.
G3TC-ODC15A G3TC-ODC24A
Operate time (see note 3) 50 μs max.
Release time (see note 3) 50 μs max. (see note 4)
Output ON voltage drop
Leakage current
Weight
1.6 V max.
1 mA max. (at 60 VDC)
Approx. 45g
1 mA max. (at 200 VDC)
Approx. 40g
Note: 1. Resistance values are reference.
2. The output module supplies the current on I/O circuit board at nominal input voltage.
3. At rated load voltage, maximum rated load current, rated input voltage and 25°C.
4. At 24 VDC load voltage, 3 A load current and 25°C.
Solid State Relays for Industrial I/O G3TC
423
Engineering Data
■ Internal Circuit
G3TC-IAC/IDC
G3TC-OAC
AC Output
AC/DC Input
In
Out
-
Out
In
-
-
Note: Internal biasing circuitry is different between AC input and DC
input modules
G3TC-ODC
DC Output
Out
-
In
-
424
Solid State Relays for Industrial I/O G3TC
■ Load Current vs. Ambient Temperature Characteristics
G3TC-ODC5A
G3TC-ODC15A
G3TC-ODC24A
2
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
G3TC-ODC5
G3TC-ODC15
G3TC-ODC24
4
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
4
3
1.5
1
3
2
2
1.6
1.6
0.55
0.5
1
1
0.37
0
0
0
−30 −20
0
20
40 45
60 70 80
100
−30 −20
0
20
40 45
60 70 80
100
−30 −20
0
20
40 45
60 70 80
100
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
■ Inrush Current Resitivity
Non-repetitive (Keep inrush current to half the rated value if it occurs.)
G3TC-OAC5
G3TC-OAC15
G3TC-OAC24
G3TC-OAC5A
G3TC-OAC15A
G3TC-OAC24A
G3TC-ODC5
G3TC-ODC5A
G3TC-ODC15
G3TC-ODC15A
G3TC-ODC24
G3TC-ODC24A
30
28
26
24
22
20
18
16
14
12
10
8
15
14
13
12
11
10
9
50
40
30
20
8
7
6
5
4
6
3
10
0
4
2
2
1
0
0
10
30 50 100 200
500 1,000
5,000
0
20 30 50 70 100
200 300 500 1,000 2,000
0
30 50
100
300 500 1,000 2,000
Energized time (ms)
Energized time (ms)
Energized time (ms)
Solid State Relays for Industrial I/O G3TC
425
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3TC-IAC5 G3TC-IAC5A
G3TC-IAC15 G3TC-IAC15A
G3TC-IAC24 G3TC-IAC24A
43.2
#4–40 Hold down screw
25.4
5
4
3
2
1
7.6
1.0 dia.
7.6
10.16
22.86
27.94
33.02
G3TC-IDC5
G3TC-IDC15
G3TC-IDC24
43.2
#4–40 Hold down screw
25.4
5
4
3
2
1
7.6
1.0 dia.
7.6
10.16
22.86
27.94
33.02
G3TC-OAC5 G3TC-OAC5A
G3TC-OAC15 G3TC-OAC15A
G3TC-OAC24 G3TC-OAC24A
43.2
#4–40 Hold down screw
25.4
4
3
2
1
7.6
1.0 dia.
10.16
7.6
22.86
27.94
426
Solid State Relays for Industrial I/O G3TC
G3TC-ODC5 G3TC-ODC5A
G3TC-ODC15 G3TC-ODC15A
G3TC-ODC24 G3TC-ODC24A
43.2
#4–40 Hold down screw
25.4
4
3
2
1
7.6
1.0 dia.
10.16
7.6
22.86
27.94
■ Approvals
UL Recognized (File No. E64562) / CSA Certified (File No. 35535) - - Ambient Temp. = 40°C
Input
Output
Model
Input voltage
90-140 V AC/DC
180-280 V AC/DC
10-32 VDC, 12-32 VAC
5 VDC
Model
Load voltage Load current
G3TC-IAC5, -IAC15, -IAC24
G3TC-IAC5, -IAC15, -IAC24
G3TC-IAC5A, -IAC15A, -IAC24A
G3TC-IDC5, -IDC15, -IDC24
G3TC-ODC5, -ODC15, -ODC24
5/15/24 VDC
5/15/24 VDC
5/15/24 VDC
5-60 VDC
50 mA
50 mA
50 mA
3 A
G3TC-IAC5A, -IAC15A, -IAC24A
G3TC-IDC5, -IDC15, -IDC24
G3TC-ODC5, -ODC5A, -OAC5, -OAC5A
G3TC-ODC15, -ODC15A, -OAC15,
-OAC15A
15 VDC
G3TC-ODC5A, -ODC15A,
-ODC24A
5-200 VDC
1 A
G3TC-ODC24, -ODC24A, -OAC24,
-OAC24A
24 VDC
G3TC-OAC5, -OAC15, -OAC24
75-140 VAC
3 A
3 A
G3TC-OAC5A, -OAC15A, -OAC24A 75-280 VAC
Note: The rated values approved by each of the safety standards (e.g., UL, CSA and TUV) may be different from the performance characteristics
individually defined in this catalog.
Solid State Relays for Industrial I/O G3TC
427
Precautions
9. For a DC inductive load, a diode should be connected in parallel
with the load to absorb the counter electromotive force of the
load.
!WARNING
Do not touch the relay while power is supplied or immediately after
G3TC is turned OFF. Doing so may result in burns.
10.For an I/O mounting rack that is installed horizontally, use the
G3TC with loads that are within the following conditions.
!WARNING
G3TC-OAC5, -OAC5A, -OAC15, -OAC15A, -OAC24, -OAC24A
Do not touch the load terminal of the G3TC immediately after the
power is turned OFF, otherwise an electric shock may be received
due to the residual charge of the built-in C/R circuit.
Horizontal Mounting
4
!WARNING
Be sure to turn OFF the power supply to the G3TC before wiring,
otherwise an electric shock may result.
3
2.1
2
!WARNING
Ensure that a short-circuit current does not flow on the load side of
the SSR, otherwise the G3TC may be damaged.
1
0.64
■ General Precautions
0
−30 −20
0
20
40 45
60 70 80
100
At OMRON, we are constantly working to improve the quality and
reliability of our products. SSRs, however, use semiconductors,
which are prone to malfunction. Be sure to use SSRs within their
rated value. Use the SSR only in systems that are designed with
redundancies, flame protection, counter measures to prevent opera-
tion errors, and other countermeasures to prevent accidents involv-
ing human life or fires.
Ambient temperature (°C)
G3TC-ODC5, -ODC15, -ODC24
Horizontal Mounting
4
1. Do not apply excessive voltage or current to the input or output
circuit of the G3TC. Doing so may result in malfunction or burning.
2. Do not connect the input and output circuits incorrectly. Doing so
3
may result in malfunction or burning.
2.7
3. Do not obstruct the flow of air around the G3TC. Abnormal heat-
ing of the G3TC may result in short-circuiting of output elements
and burning.
2
■ Correct Use
1
0.64
Before Actual Operation
0
−30 −20
0
20
40 45
60 70 80
100
1. In actual operation, the G3TC may cause accidents that were
unforeseeable at the theoretical stage. Therefore, it is necessary
to test the G3TC under a variety of conditions that are possible.
As for the characteristics of the G3TC, it is necessary to consider
the differences between G3TC models.
Ambient temperature (°C)
2. The ratings in this datasheet are for testing in a temperature
range of 15 to 30°C, a relative humidity range of 25% to 85%, and
an atmospheric pressure range of 88 to 106kPa. When testing
operation, it is necessary to confirm correct operation not only
with the actual load that will be used, but also at the same ambi-
ent conditions as for actual operation.
3. The input circuitry does not incorporate a circuit protecting the
SSR from being damaged due to a reversed connection. Make
sure that the polarity is correct when connecting the input lines.
4. Only use the G3TC with loads that are within the rated values.
Using the G3TC with loads outside the rated values may result in
malfunction, damage, or burning.
5. Use a power supply within the rated frequency range. Using a
power supply outside the rated frequency range may result in
malfunction, damage, or burning.
6. No over-voltage absorption element is built in. Therefore, if the
G3TC is connected to an inductive load, be sure to connect an
over-voltage absorption element.
7. As protection against accidents due to short-circuiting, be sure to
install protective devices, such as fuses on the power supply side.
8. Keep wiring separate from high-voltage power lines and use wires
of an appropriate length, otherwise malfunction and damage may
result due to induction.
428
Solid State Relays for Industrial I/O G3TC
■ Operating and Storage Environments
Operating Ambient Temperature
The rated value for the ambient operating temperature of the G3TC
is for when there is no built-up heat. For this, reason, under condi-
tions where heat dissipation is not good due to poor ventilation, and
where heat may build up easily, the actual temperature of the G3TC
may exceed the rated value resulting in malfunction or burning.
When using the G3TC, design the system to allow heat dissipation
sufficient to stay below the Load Current vs. Ambient Temperature
characteristic curve. Note also that the ambient temperature of the
G3TC may increase as a result of environmental conditions (e.g., cli-
mate, air-conditioning) and operating conditions (e.g., mounting in an
airtight panel).
Operating and Storage Locations
Do not use or store the G3TC in the following locations. Doing so
may result in damage, malfunction, or deterioration of performance
characteristics.
1. Do not use or store in locations subject to direct sunlight.
2. Do not use in locations subject to ambient temperatures outside
the range -30° to 80°C.
3. Do not use in locations subject to relative humidity outside the
range 45% to 85% or locations subject to condensation as the
result of severe change in temperature.
4. Do not store in locations subject to ambient temperatures outside
the range -30° to 100°C.
5. Do not use or store in locations subject to corrosive or flammable
gases.
6. Do not use or store in locations subject to dust (especially iron
dust) or salts.
7. Do not use or store in locations subject to shock or vibration.
8. Do not use or store in locations subject to exposure to water, oil,
or chemicals.
Transportation
When transporting the G3TC, observe the following points. Not doing
so may result in damage, malfunction, or deterioration of perfor-
mance characteristics.
1. Do not drop the G3TC or subject it to severe vibrations or shock.
2. Do not transport the product if it is wet.
Vibration and Shock
Do not subject the SSR to excessive vibration or shock. Otherwise
the SSR may malfunction and internal components may be dam-
aged.
Solid State Relays for Industrial I/O G3TC
429
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.components.omron.com
OMRON ELECTRONIC
COMPONENTS LLC
55 E. Commerce Drive, Suite B
Schaumburg, IL 60173
847-882-2288
09/11
Specifications subject to change without notice
Printed in USA
Cat. No. X301-E-1b
Solid State Relays for Industrial I/O G3TC
相关型号:
©2020 ICPDF网 联系我们和版权申明