G3TC-IAC15AAC/DC240 [OMRON]

Transistor Output SSR, 1-Channel, 4000V Isolation;
G3TC-IAC15AAC/DC240
型号: G3TC-IAC15AAC/DC240
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Transistor Output SSR, 1-Channel, 4000V Isolation

文件: 总12页 (文件大小:1100K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Solid State Relays for Industrial I/O  
G3TC  
Reliable SSRs for I/O Module Mounting  
Boards  
• Use I/O SSRs as an interface between logic circuitry and the load.  
• Variety of AC/DC input and output modules with industry-standard  
footprint and color coding.  
• Built-in hold down screw fastens relay to board to eliminate loosen-  
ing by vabration.  
• Optical Isolation - Dielectric strength of 4 kV between input and out-  
put terminals.  
• Zero cross function on AC output models.  
• AC and DC input versions incorporate a rectifier to accept both AC  
or DC inputs.  
• UL, CSA and TUV approved.  
Ordering Information  
Input Module  
Function  
Color  
Isolation  
Input operating  
voltage range  
Logic level output  
supply voltage  
Model  
AC input  
Yellow  
Photo-coupler  
90-140 VDC/AC  
180-280 VDC/AC  
10-32 VDC/AC  
5 VDC  
G3TC-IAC5 AC/DC120  
G3TC-IAC15 AC/DC120  
G3TC-IAC24 AC/DC120  
G3TC-IAC5A AC/DC240  
G3TC-IAC15A AC/DC240  
G3TC-IAC24A AC/DC240  
G3TC-IDC5 DC/AC24  
G3TC-IDC15 DC/AC24  
G3TC-IDC24 DC/AC24  
15 VDC  
24 VDC  
5 VDC  
15 VDC  
24 VDC  
5 VDC  
DC input  
White  
15 VDC  
24 VDC  
Output Module  
Function  
Color  
Isolation  
Photo-triac  
Rated input  
voltage  
Rated output voltage  
Model  
(Applicable output voltage)  
AC output  
Black  
5 VDC  
3 A at 120 VAC  
(3 A at 75-140 VAC)  
G3TC-OAC5 DC5  
15 VDC  
24 VDC  
5 VDC  
G3TC-OAC15 DC15  
G3TC-OAC24 DC24  
G3TC-OAC5A DC5  
G3TC-OAC15A DC15  
G3TC-OAC24A DC24  
G3TC-ODC5 DC5  
3 A at 240 VAC  
(3 A at 75-280 VAC)  
15 VDC  
24 VDC  
5 VDC  
DC output  
Red  
Photo-coupler  
3 A at 60 VDC  
(3 A at 5-60 VDC)  
15 VDC  
24 VDC  
5 VDC  
G3TC-ODC15 DC15  
G3TC-ODC24 DC24  
G3TC-ODC5A DC5  
G3TC-ODC15A DC15  
G3TC-ODC24A DC24  
1 A at 200 VDC  
(1 A at 5-200 VDC)  
15 VDC  
24 VDC  
Solid State Relays for Industrial I/O G3TC  
419  
Typical Applications  
HVAC, refrigeration equipment  
Automation controls  
Injection molding machines  
Packaging equipment  
I/O Classification by Color  
Specifications  
Common Characteristics  
Insulation resistance  
Dielectric strength  
Vibration resistance  
Shock resistance  
100 MΩ min at 500 VDC  
4000 VAC, 50/60 Hz for 1 minute between input and output  
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude  
Malfunction: 1,000 m/s2  
Ambient temperature  
Operating: -30°C to 80°C with no icing or condensation  
Storage: -30°C to 100°C with no icing or condensation  
Operating: 45% to 85%  
Ambient humidity  
Approved standards  
UL Recognized, CSA Certified, EN60950  
420  
Solid State Relays for Industrial I/O G3TC  
AC Input Module G3TC-IAC  
Ratings (Ambient Temperature 25°C)  
Input  
Item  
G3TC-IAC5  
120 VAC/DC  
90-140 VAC/DC  
90 VAC/DC max.  
25 VAC/DC min.  
5 mA max.  
G3TC-IAC15  
G3TC-IAC24  
G3TC-IAC5A  
240 VAC/DC  
180-280 VAC/DC  
180 VAC/DC max.  
45 VAC/DC min.  
5 mA max.  
G3TC-IAC15A G3TC-IAC24A  
Rated voltage  
Operating voltage  
Must operate voltage  
Must release voltage  
Input current at rated voltage  
Input resistance (see note 1)  
30 kΩ  
69 kΩ  
Output  
Item  
G3TC-IAC5  
5 VDC  
G3TC-IAC15  
15 VDC  
G3TC-IAC24  
24 VDC  
G3TC-IAC5A  
5 VDC  
G3TC-IAC15A G3TC-IAC24A  
Output supply voltage-nominal  
Output supply voltage-range  
15 VDC  
24 VDC  
4.5-6 VDC  
18 mA max.  
12-18 VDC  
15 mA max.  
20-30 VDC  
12 mA max.  
4.5-6 VDC  
18 mA max.  
12-18 VDC  
15 mA max.  
20-30 VDC  
12 mA max.  
Output supply current at rated  
input voltage (see note 2)  
Control resistance (Rc in circuit 240 Ω  
1 kΩ  
2.2 kΩ  
240 Ω  
1k Ω  
2.2k Ω  
configuration - see note 1)  
Output current  
50 mA max.  
Characteristics  
Item  
Operate time (see note 3)  
Release time (see note 3)  
Output ON voltage drop  
Leakage current  
G3TC-IAC5  
20 ms max.  
20 ms max.  
0.4 V max.  
G3TC-IAC15  
G3TC-IAC24  
G3TC-IAC5A  
G3TC-IAC15A G3TC-IAC24A  
100 μA max.  
Approx. 40g  
Weight  
Note: 1. Resistance values are reference.  
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.  
3. At nominal output supply voltage, rated input voltage and 25°C.  
DC Input Module G3TC-IDC  
Ratings (Ambient Temperature 25°C)  
Input  
Item  
G3TC-IDC5  
24 VDC/AC  
G3TC-IDC15  
G3TC-IDC24  
Rated voltage  
Operating voltage  
10-32 VDC/ 15-32 VAC  
10 VDC/15 VAC max.  
3 VDC/ 3 VAC min.  
25 mA max.  
Must operate voltage  
Must release voltage  
Input current rated voltage  
Input resistance (see note 1)  
1.5 kΩ  
Output  
Item  
G3TC-IDC5  
5 VDC  
G3TC-IDC15  
15 VDC  
G3TC-IDC24  
24 VDC  
Output supply voltage-nominal  
Output supply voltage-range  
4.5-6 VDC  
12-18 VDC  
15 mA max.  
1 kΩ  
20-30 VDC  
12 mA max.  
2.2 kΩ  
Output supply current at rated input voltage (see note 2)  
18 mA max.  
Control resistance (Rc in circuit configuration - see note 1) 240 Ω  
Output current 50 mA max.  
Solid State Relays for Industrial I/O G3TC  
421  
Characteristics  
Item  
G3TC-IDC5  
5 ms max.  
G3TC-IDC15  
G3TC-IDC24  
Operate time (see note 3)  
Release time (see note 3)  
Output ON voltage drop  
Leakage current  
5 ms max.  
0.4 V max.  
100 μA max.  
Approx. 40g  
Weight  
Note: 1. Resistance values are reference.  
2. The input module supplies the current on I/O circuit board at nominal ouput voltage.  
3. At nominal output supply voltage, rated input voltage and 25°C.  
AC Output Module G3TC-OAC  
Ratings (Ambient Temperature 25°C)  
Input  
Item  
Rated voltage  
G3TC-OAC5  
5 VDC  
G3TC-OAC15  
15 VDC  
G3TC-OAC24  
24 VDC  
G3TC-OAC5A  
5 VDC  
G3TC-OAC15A  
G3TC-OAC24A  
15 VDC  
24 VDC  
Operating voltage  
2.5-8 VDC  
9-16 VDC  
18-32 VDC  
2.5-8 VDC  
9-16 VDC  
9 VDC max.  
18-32 VDC  
18 VDC max.  
Must operate  
voltage  
2.5 VDC max.  
9 VDC max.  
18 VDC max.  
2.5 VDC max.  
Must release  
voltage  
1 VDC min.  
18 mA max.  
Input current at rated  
voltage (see note 2)  
Control resistance (Rc 240 Ω  
in circuit configuration  
- see note 1)  
1 kΩ  
2.2 kΩ  
240 Ω  
1 kΩ  
2.2 kΩ  
Output  
Item  
G3TC-OAC5  
G3TC-OAC15  
G3TC-OAC24  
G3TC-OAC5A  
240 VAC  
G3TC-OAC15A  
G3TC-OAC24A  
Rated load voltage  
Load voltage range  
Load current  
120 VAC  
75-140 VAC  
0.05 to 3 A  
75-280 VAC  
Inrush current  
45 A (60 Hz, 1 cycle)  
Characteristics  
Item  
G3TC-OAC5  
G3TC-OAC15  
G3TC-OAC24  
G3TC-OAC5A  
G3TC-OAC15A  
G3TC-OAC24A  
Operate time (see note 3) 1/2 of load power source cycle + 1 ms max.  
Release time (see note 3) 1/2 of load power source cycle + 1 ms max.  
Output ON voltage drop  
Leakage current  
Weight  
1.6 V (RMS) max.  
2.5 mA max. (at 120 VAC)  
Approx. 45g  
5 mA max. (at 240 VAC)  
Note: 1. Resistance values are reference.  
2. The output module supplies the current on I/O circuit board at nominal input voltage.  
3. At nominal output supply voltage, rated input voltage and 25°C.  
422  
Solid State Relays for Industrial I/O G3TC  
DC Output Module G3TC-ODC  
Ratings (Ambient Temperature 25°C)  
Input  
Item  
G3TC-ODC5  
5 VDC  
G3TC-ODC15  
15 VDC  
G3TC-ODC24  
24 VDC  
G3TC-ODC5A  
5 VDC  
G3TC-ODC15A  
15 VDC  
G3TC-ODC24A  
24 VDC  
Rated voltage  
Operating voltage  
2.5-8 VDC  
9-16 VDC  
18-32 VDC  
2.5-8 VDC  
9-16 VDC  
18-32 VDC  
Must operate  
voltage  
2.5 VDC max.  
9 VDC max.  
18 VDC max.  
2.5 VDC max.  
9 VDC max.  
18 VDC max.  
Must release  
voltage  
1 VDC min.  
Input current at rated 18 mA max.  
voltage (see note 2)  
Control resistance (Rc 240 Ω  
in circuit configuration  
- see note 1)  
1 kΩ  
2.2 kΩ  
240 Ω  
1 kΩ  
2.2 kΩ  
Output  
Item  
G3TC-ODC5  
G3TC-ODC15  
G3TC-ODC24  
G3TC-ODC5A  
200 VDC  
G3TC-ODC15A  
G3TC-ODC24A  
Rated load voltage  
Load voltage range  
Load current  
60 VDC  
5-60 VDC  
0.01 to 3 A  
18 A (10 ms)  
5-200 VDC  
0.01 to 1.0 A  
9 A (10 ms)  
Inrush current  
Characteristics  
Item  
G3TC-ODC5  
G3TC-ODC15  
G3TC-ODC24  
G3TC-ODC5A  
100 μs max.  
750 μs max.  
G3TC-ODC15A G3TC-ODC24A  
Operate time (see note 3) 50 μs max.  
Release time (see note 3) 50 μs max. (see note 4)  
Output ON voltage drop  
Leakage current  
Weight  
1.6 V max.  
1 mA max. (at 60 VDC)  
Approx. 45g  
1 mA max. (at 200 VDC)  
Approx. 40g  
Note: 1. Resistance values are reference.  
2. The output module supplies the current on I/O circuit board at nominal input voltage.  
3. At rated load voltage, maximum rated load current, rated input voltage and 25°C.  
4. At 24 VDC load voltage, 3 A load current and 25°C.  
Solid State Relays for Industrial I/O G3TC  
423  
Engineering Data  
Internal Circuit  
G3TC-IAC/IDC  
G3TC-OAC  
AC Output  
AC/DC Input  
In  
Out  
-
Out  
In  
-
-
Note: Internal biasing circuitry is different between AC input and DC  
input modules  
G3TC-ODC  
DC Output  
Out  
-
In  
-
424  
Solid State Relays for Industrial I/O G3TC  
Load Current vs. Ambient Temperature Characteristics  
G3TC-ODC5A  
G3TC-ODC15A  
G3TC-ODC24A  
2
G3TC-OAC5A  
G3TC-OAC15A  
G3TC-OAC24A  
G3TC-ODC5  
G3TC-ODC15  
G3TC-ODC24  
4
G3TC-OAC5  
G3TC-OAC15  
G3TC-OAC24  
4
3
1.5  
1
3
2
2
1.6  
1.6  
0.55  
0.5  
1
1
0.37  
0
0
0
30 20  
0
20  
40 45  
60 70 80  
100  
30 20  
0
20  
40 45  
60 70 80  
100  
30 20  
0
20  
40 45  
60 70 80  
100  
Ambient temperature (°C)  
Ambient temperature (°C)  
Ambient temperature (°C)  
Inrush Current Resitivity  
Non-repetitive (Keep inrush current to half the rated value if it occurs.)  
G3TC-OAC5  
G3TC-OAC15  
G3TC-OAC24  
G3TC-OAC5A  
G3TC-OAC15A  
G3TC-OAC24A  
G3TC-ODC5  
G3TC-ODC5A  
G3TC-ODC15  
G3TC-ODC15A  
G3TC-ODC24  
G3TC-ODC24A  
30  
28  
26  
24  
22  
20  
18  
16  
14  
12  
10  
8
15  
14  
13  
12  
11  
10  
9
50  
40  
30  
20  
8
7
6
5
4
6
3
10  
0
4
2
2
1
0
0
10  
30 50 100 200  
500 1,000  
5,000  
0
20 30 50 70 100  
200 300 500 1,000 2,000  
0
30 50  
100  
300 500 1,000 2,000  
Energized time (ms)  
Energized time (ms)  
Energized time (ms)  
Solid State Relays for Industrial I/O G3TC  
425  
Dimensions  
Note: All units are in millimeters unless otherwise indicated.  
G3TC-IAC5 G3TC-IAC5A  
G3TC-IAC15 G3TC-IAC15A  
G3TC-IAC24 G3TC-IAC24A  
43.2  
#4–40 Hold down screw  
25.4  
5
4
3
2
1
7.6  
1.0 dia.  
7.6  
10.16  
22.86  
27.94  
33.02  
G3TC-IDC5  
G3TC-IDC15  
G3TC-IDC24  
43.2  
#4–40 Hold down screw  
25.4  
5
4
3
2
1
7.6  
1.0 dia.  
7.6  
10.16  
22.86  
27.94  
33.02  
G3TC-OAC5 G3TC-OAC5A  
G3TC-OAC15 G3TC-OAC15A  
G3TC-OAC24 G3TC-OAC24A  
43.2  
#4–40 Hold down screw  
25.4  
4
3
2
1
7.6  
1.0 dia.  
10.16  
7.6  
22.86  
27.94  
426  
Solid State Relays for Industrial I/O G3TC  
G3TC-ODC5 G3TC-ODC5A  
G3TC-ODC15 G3TC-ODC15A  
G3TC-ODC24 G3TC-ODC24A  
43.2  
#4–40 Hold down screw  
25.4  
4
3
2
1
7.6  
1.0 dia.  
10.16  
7.6  
22.86  
27.94  
Approvals  
UL Recognized (File No. E64562) / CSA Certified (File No. 35535) - - Ambient Temp. = 40°C  
Input  
Output  
Model  
Input voltage  
90-140 V AC/DC  
180-280 V AC/DC  
10-32 VDC, 12-32 VAC  
5 VDC  
Model  
Load voltage Load current  
G3TC-IAC5, -IAC15, -IAC24  
G3TC-IAC5, -IAC15, -IAC24  
G3TC-IAC5A, -IAC15A, -IAC24A  
G3TC-IDC5, -IDC15, -IDC24  
G3TC-ODC5, -ODC15, -ODC24  
5/15/24 VDC  
5/15/24 VDC  
5/15/24 VDC  
5-60 VDC  
50 mA  
50 mA  
50 mA  
3 A  
G3TC-IAC5A, -IAC15A, -IAC24A  
G3TC-IDC5, -IDC15, -IDC24  
G3TC-ODC5, -ODC5A, -OAC5, -OAC5A  
G3TC-ODC15, -ODC15A, -OAC15,  
-OAC15A  
15 VDC  
G3TC-ODC5A, -ODC15A,  
-ODC24A  
5-200 VDC  
1 A  
G3TC-ODC24, -ODC24A, -OAC24,  
-OAC24A  
24 VDC  
G3TC-OAC5, -OAC15, -OAC24  
75-140 VAC  
3 A  
3 A  
G3TC-OAC5A, -OAC15A, -OAC24A 75-280 VAC  
Note: The rated values approved by each of the safety standards (e.g., UL, CSA and TUV) may be different from the performance characteristics  
individually defined in this catalog.  
Solid State Relays for Industrial I/O G3TC  
427  
Precautions  
9. For a DC inductive load, a diode should be connected in parallel  
with the load to absorb the counter electromotive force of the  
load.  
!WARNING  
Do not touch the relay while power is supplied or immediately after  
G3TC is turned OFF. Doing so may result in burns.  
10.For an I/O mounting rack that is installed horizontally, use the  
G3TC with loads that are within the following conditions.  
!WARNING  
G3TC-OAC5, -OAC5A, -OAC15, -OAC15A, -OAC24, -OAC24A  
Do not touch the load terminal of the G3TC immediately after the  
power is turned OFF, otherwise an electric shock may be received  
due to the residual charge of the built-in C/R circuit.  
Horizontal Mounting  
4
!WARNING  
Be sure to turn OFF the power supply to the G3TC before wiring,  
otherwise an electric shock may result.  
3
2.1  
2
!WARNING  
Ensure that a short-circuit current does not flow on the load side of  
the SSR, otherwise the G3TC may be damaged.  
1
0.64  
General Precautions  
0
30 20  
0
20  
40 45  
60 70 80  
100  
At OMRON, we are constantly working to improve the quality and  
reliability of our products. SSRs, however, use semiconductors,  
which are prone to malfunction. Be sure to use SSRs within their  
rated value. Use the SSR only in systems that are designed with  
redundancies, flame protection, counter measures to prevent opera-  
tion errors, and other countermeasures to prevent accidents involv-  
ing human life or fires.  
Ambient temperature (°C)  
G3TC-ODC5, -ODC15, -ODC24  
Horizontal Mounting  
4
1. Do not apply excessive voltage or current to the input or output  
circuit of the G3TC. Doing so may result in malfunction or burning.  
2. Do not connect the input and output circuits incorrectly. Doing so  
3
may result in malfunction or burning.  
2.7  
3. Do not obstruct the flow of air around the G3TC. Abnormal heat-  
ing of the G3TC may result in short-circuiting of output elements  
and burning.  
2
Correct Use  
1
0.64  
Before Actual Operation  
0
30 20  
0
20  
40 45  
60 70 80  
100  
1. In actual operation, the G3TC may cause accidents that were  
unforeseeable at the theoretical stage. Therefore, it is necessary  
to test the G3TC under a variety of conditions that are possible.  
As for the characteristics of the G3TC, it is necessary to consider  
the differences between G3TC models.  
Ambient temperature (°C)  
2. The ratings in this datasheet are for testing in a temperature  
range of 15 to 30°C, a relative humidity range of 25% to 85%, and  
an atmospheric pressure range of 88 to 106kPa. When testing  
operation, it is necessary to confirm correct operation not only  
with the actual load that will be used, but also at the same ambi-  
ent conditions as for actual operation.  
3. The input circuitry does not incorporate a circuit protecting the  
SSR from being damaged due to a reversed connection. Make  
sure that the polarity is correct when connecting the input lines.  
4. Only use the G3TC with loads that are within the rated values.  
Using the G3TC with loads outside the rated values may result in  
malfunction, damage, or burning.  
5. Use a power supply within the rated frequency range. Using a  
power supply outside the rated frequency range may result in  
malfunction, damage, or burning.  
6. No over-voltage absorption element is built in. Therefore, if the  
G3TC is connected to an inductive load, be sure to connect an  
over-voltage absorption element.  
7. As protection against accidents due to short-circuiting, be sure to  
install protective devices, such as fuses on the power supply side.  
8. Keep wiring separate from high-voltage power lines and use wires  
of an appropriate length, otherwise malfunction and damage may  
result due to induction.  
428  
Solid State Relays for Industrial I/O G3TC  
Operating and Storage Environments  
Operating Ambient Temperature  
The rated value for the ambient operating temperature of the G3TC  
is for when there is no built-up heat. For this, reason, under condi-  
tions where heat dissipation is not good due to poor ventilation, and  
where heat may build up easily, the actual temperature of the G3TC  
may exceed the rated value resulting in malfunction or burning.  
When using the G3TC, design the system to allow heat dissipation  
sufficient to stay below the Load Current vs. Ambient Temperature  
characteristic curve. Note also that the ambient temperature of the  
G3TC may increase as a result of environmental conditions (e.g., cli-  
mate, air-conditioning) and operating conditions (e.g., mounting in an  
airtight panel).  
Operating and Storage Locations  
Do not use or store the G3TC in the following locations. Doing so  
may result in damage, malfunction, or deterioration of performance  
characteristics.  
1. Do not use or store in locations subject to direct sunlight.  
2. Do not use in locations subject to ambient temperatures outside  
the range -30° to 80°C.  
3. Do not use in locations subject to relative humidity outside the  
range 45% to 85% or locations subject to condensation as the  
result of severe change in temperature.  
4. Do not store in locations subject to ambient temperatures outside  
the range -30° to 100°C.  
5. Do not use or store in locations subject to corrosive or flammable  
gases.  
6. Do not use or store in locations subject to dust (especially iron  
dust) or salts.  
7. Do not use or store in locations subject to shock or vibration.  
8. Do not use or store in locations subject to exposure to water, oil,  
or chemicals.  
Transportation  
When transporting the G3TC, observe the following points. Not doing  
so may result in damage, malfunction, or deterioration of perfor-  
mance characteristics.  
1. Do not drop the G3TC or subject it to severe vibrations or shock.  
2. Do not transport the product if it is wet.  
Vibration and Shock  
Do not subject the SSR to excessive vibration or shock. Otherwise  
the SSR may malfunction and internal components may be dam-  
aged.  
Solid State Relays for Industrial I/O G3TC  
429  
All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which  
can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.  
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.components.omron.com  
OMRON ELECTRONIC  
COMPONENTS LLC  
55 E. Commerce Drive, Suite B  
Schaumburg, IL 60173  
847-882-2288  
09/11  
Specifications subject to change without notice  
Printed in USA  
Cat. No. X301-E-1b  
Solid State Relays for Industrial I/O G3TC  

相关型号:

G3TC-IAC15AC/DC120

Transistor Output SSR, 1-Channel, 4000V Isolation
OMRON

G3TC-IAC24

Solid State Relays for Industrial I/O
OMRON

G3TC-IAC24A

Solid State Relays for Industrial I/O
OMRON

G3TC-IAC24AC/DC120

Transistor Output SSR, 1-Channel, 4000V Isolation
OMRON

G3TC-IAC5

Solid State Relays for Industrial I/O
OMRON

G3TC-IAC5A

Solid State Relays for Industrial I/O
OMRON

G3TC-IAC5AAC/DC240

Transistor Output SSR, 1-Channel, 4000V Isolation
OMRON

G3TC-IAC5AC/DC120

Transistor Output SSR, 1-Channel, 4000V Isolation
OMRON

G3TC-IDC15

Solid State Relays for Industrial I/O
OMRON

G3TC-IDC15DC/AC24

Transistor Output SSR, 1-Channel, 4000V Isolation
OMRON

G3TC-IDC24

Solid State Relays for Industrial I/O
OMRON

G3TC-IDC5

Solid State Relays for Industrial I/O
OMRON