G3TB-OD201P-US-24 [OMRON]
Transistor Output SSR;型号: | G3TB-OD201P-US-24 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Transistor Output SSR 输出元件 光电 |
文件: | 总10页 (文件大小:1344K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Relay
G3TB
I/O SSR Used as Interface between Logic
Circuitry and Load
• A variety of AC/DC input and output modules classified by
color.
• Operation can be monitored easily through an LED indicator.
• Dielectric strength of 4,000 V between input and output
terminals.
• Certified by UL and CSA.
Ordering Information
Input Modules
Isolation
Indicator
Logic level
Supply voltage Supply current
4 to 32 VDC 25 mA
Rated input
voltage
Model
Photocoupler
Yes
100 to 240 VAC
4 to 24 VDC
G3TB-IAZR02P-US
G3TB-IDZR02P-US
Output Modules
Isolation
Zero cross
function
Indicator
Rated output voltage
(Applicable output
load)
Rated input voltage
Model
Photocoupler
Yes
No
---
Yes
No
3 A at 100 to 240 VAC 5 to 24 VDC
G3TB-OA203PZ-US
G3TB-OA203PZM-US
G3TB-OA203PL-US
G3TB-OA203PLM-US
G3TB-ODX03P-US
G3TB-ODX03PM-US
G3TB-OD201P-US
G3TB-OD201PM-US
(3 A at 75 to 264 VAC)
4 to 24 VDC
Yes
No
5 to 24 VDC
4 to 24 VDC
Yes
No
3 A at 5 to 48 VDC
(3 A at 4 to 60 VAC)
5 to 24 VDC
4 to 24 VDC
Yes
No
1.5 A at 48 to 200 VDC 5 to 24 VDC
(1.5 A at 40 to 200 VDC)
4 to 24 VDC
Note: When ordering, specify the rated input voltage.
Solid State Relay G3TB
387
Specifications
■ Ratings (at an Ambient Temperature of 25°C)
Input Module
Input
Model
Rated voltage
Operating voltage
Input current
5 mA max.
Voltage level
Must operate voltage Must release voltage
G3TB-IAZR02P-US
G3TB-IDZR02P-US
100 to 240 VAC
4 to 24 VDC
80 to 264 VDC
3 to 32 VDC
80 VAC max.
3 VDC max.
10 VAC min.
1 VDC min.
Output
Model
Logic level supply voltage
4 to 32 VDC
Output breakdown voltage
32 VDC max.
Output current
G3TB-IAZR02P-US
G3TB-IDZR02P-US
25 mA max.
Output Module
Input
Model
Rated voltage
5 to 24 VDC
Operating voltage
Input current
5 mA max.
Voltage level
Must operate voltage Must release voltage
G3TB-OA203PZ-US
G3TB-OA203PZM-US 4 to 24 VDC
G3TB-OA203PL-US 5 to 24 VDC
G3TB-OA203PLM-US 4 to 24 VDC
G3TB-ODX03P-US 5 to 24 VDC
G3TB-ODX03PM-US 4 to 24 VDC
G3TB-OD201P-US 5 to 24 VDC
4 to 32 VDC
3 to 32 VDC
4 to 32 VDC
3 to 32 VDC
4 to 32 VDC
3 to 32 VDC
4 to 32 VDC
3 to 32 VDC
4 VDC max.
1 VDC min.
3 VDC max.
4 VDC max.
3 VDC max.
4 VDC max.
3 VDC max.
4 VDC max.
3 VDC max.
G3TB-OD201PM-US 4 to 24 VDC
Output
Model
Applicable load
Rated load voltage
Load voltage range
75 to 264 VAC
Load current (See note.)
Inrush current
G3TB-OA203PZ-US
G3TB-OA203PZM-US
G3TB-OA203PL-US
G3TB-OA203PLM-US
G3TB-ODX03P-US
G3TB-ODX03PM-US
G3TB-OD201P-US
G3TB-OD201PM-US
100 to 240 VAC
0.05 to 3 A
45 A (60 Hz, 1 cycle)
5 to 48 VDC
4 to 60 VDC
0.01 to 3 A
18 A (10 ms)
12 A (10 ms)
48 to 200 VDC
40 to 200 VDC
0.01 to 1.5 A
Note: The minimum current value is measured at 10°C min.
388
Solid State Relay G3TB
■ Characteristics
Input Module
Item
G3TB-IAZR02P-US
G3TB-IDZR02P-US
Operate time
Release time
20 ms max.
20 ms max.
1 ms max.
1 ms max.
Output ON voltage drop 0.4 V max.
Leakage current
100 μA max.
100 MΩ min. (at 500 VDC)
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
4,000 VAC, 50/60 Hz for 1 min between input and output
Malfunction: 10 to 55 Hz, 1.5-mm single amplitude
Malfunction: 1,000 m/s2
Ambient temperature
Operating:
Storage:
–30°C to 80°C (with no icing or condensation)
–30°C to 100°C (with no icing or condensation)
Ambient humidity
Certified standards
Weight
Operating: 45% to 85%
UL File No. E41515/CSA File No. LR35535/TÜV R90381 (VDE0806)
Approx. 22 g
Output Module
Item
G3TB-
G3TB-
G3TB-OA
G3TB-OA
G3TB-
G3TB-
G3TB-OD
G3TB-OD
201PM-US
OA203PZ-US OA203PZM-US 203PL-US 203PLM-US ODX03P-US ODX03PM-US 201P-US
Operate time
1/2 of load power source cycle + 1 ms max.
1 ms max.
0.5 ms max.
2 ms max.
Release time
1/2 of load power source cycle + 1 ms max.
1.6 V max.
Output ON voltage
drop
2.5 V max.
Leakage current
5 mA max. (at 200 VAC)
1 mA max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric strength
4,000 VAC, 50/60 Hz for 1 min between input and output
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm single amplitude
Malfunction: 1,000 m/s2
Shock resistance
Ambienttemperature Operating: –30°C to 80°C (with no icing or condensation)
Storage: –30°C to 100°C (with no icing or condensation)
Operating: 45% to 85%
Certified standards UL File No. E64562/CSA File No. LR35535/TÜV R90381 (VDE0806)
Weight Approx. 32 g
Ambient humidity
Solid State Relay G3TB
389
Engineering Data
Load Current vs. Ambient Temperature Characteristics
G3TB-OA203PZ-US/-OA203PZM-US
/-OA203PL-US/-OA203PLM-US/
G3TB-ODX03P-US/-ODX03PM-US
G3TB-OD201P-US/-OD201PM-US
Ambient temperature (°C)
Ambient temperature (°C)
One Cycle Surge Current: Non-repetitive
Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.)
G3TB-OA203PZ-US/-OA203PZM-US/
-OA203PL-US/-OA203PLM-US
G3TB-ODX03P-US/-ODX03PM-US
G3TB-OD201P-US/-OD201PM-US
Energized time (ms)
Energized time (ms)
Energized time (ms)
390
Solid State Relay G3TB
Operation
■ Circuit Configuration
Type
Model
Case
color
Indicator
Yes
Circuit
AC input
G3TB-IAZR02P-US
Yellow
Constant-
current circuit
Rectification
circuit
Amplification
circuit
DC input
G3TB-IDZR02P-US
White
Black
Yes
Constant-
current circuit
Amplification
circuit
AC output
G3TB-OA203PZ-US
G3TB-OA203PL-US
Yes
No
Constant-
current circuit
Zero cross
circuit
Drive circuit
G3TB-OA203PZM-US
G3TB-OA203PLM-US
DC output
G3TB-ODX03P-US
G3TB-OD201P-US
Red
Yes
No
Constant-
current circuit
Amplification
circuit
G3TB-ODX03PM-US
G3TB-OD201PM-US
Example of Logic Output Circuit
Example 1. G3TB-I
Example 2. G3TB-I
4 to 32 VDC
3.3 K
3.3 K
+3
4
+3
SW
SW
(+)
(+)
Load
4
Sequential
circuit or
CPU
(
)
(
)
4 to 32 VDC
Example: Relay
with built-in
inrush absorption
diode
(−)
(−)
−5
−5
Logic circuitry
Note: AC- and DC-input versions are available.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Input SSR
G3TB-I
PCB Dimensions
(Bottom View)
Five, 1.3-dia. holes
2.54
10 max.
2.54
20.5
max.
23.2
5.08 5.08
6.05
10.16
12.7
6.05 0.1
6.6
0.6
10.16
22.86
27.94
33.02
43.5 max.
Terminal Arrangement
(Bottom View)
External input
Output
External input
Output
1
1
2
3
4
5
2
3
4
5
+
−
+
-
~
~
+
−
Vcc
Vcc
Solid State Relay G3TB
391
Output SSR
G3TB-O
PCB Dimensions
(Bottom View)
10 max.
Four, 1.2-dia. holes
2.54
2.54
29.5
30.5
max.
33.2
6.05
5.08
10.16
12.7
6.05 0.1
10.16
22.86
27.94
43.5 max.
6.6
0.6
Terminal Arrangement
(Bottom View)
External AC output
Logic input
External DC output
Logic input
1
~
1
~
2
3
4
2
3
4
~
+
-
~
+
−
Z
2
Z
Z
1
Load
Load
Note: Z1, Z2, and Z refer to overvoltage absorption elements that
you should connect.
392
Solid State Relay G3TB
Safety Precautions
■ Precautions for Correct Use
Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance.
G3TB
I/O classification by the color is as follows:
G3TB-IAZR02P
AC input module
Yellow
White
Black
AC equipment
DC equipment
100 to 240 VAC
5 to 24 VAC
5 to 24 VDC
5 to 24 VDC
G3TB-IDZR02P
DC input module
G3TB-OA203PZ
G3TB-OA203PZM
G3TB-OA203PL
G3TB-OA203PLM
AC output module
5 to 24 VDC
(4 to 24 VDC)
100 to 240 VAC 3 A
AC equipment
PLC or logic circuitry
G3TB-ODX03P
G3TB-ODX03PM
G3TB-OD201P*
G3TB-OD201PM*
DC output module
Red
5 to 24 VDC
(4 to 24 VDC)
4 to 60 VDC/
DC equipment
40 to 200 VAC 3 A
*With 1.5-A output.
When mounting more than one output module, make a distance of 5
mm minimum between adjacent SSRs. Up to 16-point, 3-A load
switching is possible
Connection
With the SSR for DC switching, the load can be connected to either
positive or negative output terminal of the SSR.
Output module
5 mm min.
Protective Component
Since the SSR does not incorporate an overvoltage absorption com-
ponent, be sure to connect an overvoltage absorption component
when using the SSR under an inductive load.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Solid State Relay G3TB
393
MEMO
394
Solid State Relay G3TB
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
•
•
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
•
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS • Schaumburg, IL USA • ꢀꢁꢂ.ꢀꢁꢃ.ꢂꢄꢅꢅ • ꢀꢅꢅ.ꢆꢆꢇ.ꢇꢂꢇꢇ • www.omronꢈꢁꢂ.com
OMRON CANADA, INC. • HEAD OFFICE
Toronto, ON, Canada • 416.286.6465 • 866.986.6766
www.omron247.com
OMRON ARGENTINA • SALES OFFICE
Cono Sur • 54.11.4783.5300
OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE
São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br
OMRON CHILE • SALES OFFICE
Santiago • 56.9.9917.3920
OMRON ELECTRONICS MEXICO SA DE CV • HEAD OFFICE
Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com
OTHER OMRON LATIN AMERICA SALES
54.11.4783.5300
OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu
Cat. No. J30I-E-01
06/09
Note: Specifications are subject to change.
© 2010 Omron Electronics LLC
相关型号: