Plastic Cylindrical Inductive Prox
E2F
Short Length, Shielded Sensors With
Threaded Plastic Body
■ Rugged, watertight plastic housing offers
good chemical resistance and with-
stands washdown
■ Wide operating voltages: 10 to 30 VDC
and 20 to 264 VAC
■ Operation indicator on all models
■ Short-circuit protection available on all
DC and some AC models
Ordering Information
■ DC THREE-WIRE PREWIRED MODELS
Type
Size
M8
Sensing distance
1.5 mm
Output
configuration
Part number
NO
NC
Shielded
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
E2F-X1R5E1
E2F-X1R5F1
E2F-X2E1
E2F-X2F1
E2F-X5E1
E2F-X5F1
E2F-X10E1
E2F-X10F1
E2F-X1R5E2
E2F-X1R5F2
E2F-X2E2
E2F-X2F2
M12
M18
M30
2 mm
5 mm
E2F-X5E2
E2F-X5F2
10 mm
E2F-X10E2
E2F-X10F2
■ AC TWO-WIRE PREWIRED MODELS
Without Short-CIrcuit Protection
Type
Size
Sensing distance
Part number
NO
NC
Shielded
M8
1.5 mm
2 mm
E2F-X1R5Y1
E2F-X2Y1
E2F-X1R5Y2
E2F-X2Y2
E2F-X5Y2-US
E2F-X10Y2-US
M12
M18
M30
5 mm
E2F-X5Y1-US
E2F-X10Y1-US
10 mm
With Short-CIrcuit Protection
Type
Size
Sensing distance
Part number
NO
NC
Shielded
M18
M30
5 mm
E2F-X5Y1-53-US
E2F-X5Y2-53-US
10 mm
E2F-X10Y1-53-US
E2F-X10Y2-53-US
2
E2F
E2F
■ ACCESSORIES
Description
Part number
Y92E-B8
Mounting brackets
Fits M8 size sensors
Fits M12 size sensors
Fits M18 size sensors
Fits M30 size sensors
Y92E-B12
Y92E-B18
Y92E-B30
■ REPLACEMENT PARTS
Description
Part number
M8-PHWS
Mounting hardware:
one pair of plastic nuts
Fits M8 size sensors (supplied with each sensor)
Fits M12 size sensors (supplied with each sensor)
Fits M18 size sensors (supplied with each sensor)
Fits M30 size sensors (supplied with each sensor)
M12-PHWS
M18-PHWS
M30-PHWS
3
E2F
E2F
Specifications
■ DC 3-WIRE MODELS
Part number
Sensor Type
E2F-X1R5ꢀꢀ
Inductive
E2F-X2ꢀꢀ
E2F-X5ꢀꢀ
E2F-X10ꢀꢀ
Body
Size
Type
M8
M12
M18
M30
Shielded
Supply voltage
10 to 30 VDC
17 mA max.
Metallic objects
Current consumption
Detectable object type
Effective maximum detecting
distance (with standard target)
1.5 mm (0.06 in)
±15%
2 mm (0.08 in)
±10%
5 mm (0.20 in)
±10%
10 mm (0.39 in)
±10%
Usable detecting range
(with standard target)
0 to 1.2 mm
(0 to 0.05 in)
0 to 1.6 mm
(0 to 0.06 in)
0 to 4 mm
(0 to 0.16 in)
0 to 8 mm
(0 to 0.31 in)
Standard target size
(mild steel, L x W x H)
8 x 8 x 1 mm
(0.31 x 0.31 x 0.04 in)
12 x 12 x 1 mm
(0.47 x 0.47 x 0.04 in)
18 x 18 x 1 mm
(0.71 x 0.71 x 0.04 in)
30 x 30 x 1 mm
(1.18 x 1.18 x 0.04 in)
Differential travel
10% max. of effective max. detecting distance
DC
solid-
state
Control
output
Type
NPN-NO open collector with pull-up (E2F-XꢀꢀE1)
NPN-NC open collector with pull-up (E2F-XꢀꢀE2)
PNP-NO open collector with pull-down (E2F-XꢀꢀF1)
PNP-NC open collector with pull-down (E2F-XꢀꢀF2)
Max. load
200 mA
2 VDC
Max. on-state
voltage drop
Response frequency
2 Hz
1.5 kHz
600 Hz
400 Hz
Circuit
protection
Ouput short-
circuit
Provided; automatic resetting type
DC power
supply reverse
polarity
Provided
Weld field
immunity
Not provided
RFI immunity
Not provided
Target Present (red LED)
Plastic
Indicators
Materials
Housing
Sensing face
Cable sheath
Plastic
Plastic
Mounting
Two plastic M8 nuts
included. Bracket
Y92E-B8 optional.
Two plastic M12 nuts
included. Bracket
Y92E-B12 optional.
Two plastic M18 nuts
included. Bracket
Y92E-B18 optional.
Two plastic M30 nuts
included. Bracket
Y92E-B30 optional.
Connections
Prewired
3-conductor cable, 2 m (6.56 ft) length
Weight with cable
Approx. 40 g
(1.4 oz)
Approx. 50 g
(1.8 oz)
Approx. 130 g
(4.6 oz)
Approx. 170 g
(6.0 oz)
Enclosure
ratings
UL
—
NEMA
IEC 144
UL
1, 3, 4, 6, 12, 13
IP68
—
Approvals
CSA
—
Ambient operating temperature
-25°C to 70°C (-13° to 158°F)
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Approx. 100 G
Vibration
Shock
4
E2F
E2F
■ AC 2-WIRE MODELS
Part number
E2E2F-X1R5Yꢀ
E2F-X2Yꢀ
E2F-X5Yꢀ-US
E2F-X10Yꢀ-US
E2F-X5Yꢀ-53-US
E2F-X10Yꢀ-53-US
Sensor Type
Inductive
Body
Size
M8
M12
M18
M30
Type
Shielded
Supply voltage
20 to 264 VDC, 50/60 Hz
20 to 264 VAC, 50/60 Hz (E2F-XꢀꢀYꢀ-US)
90 to 140 VAC, 50/60 Hz (E2F-XꢀꢀYꢀ-53-US)
Current consumption
Detectable object type
5 mA max.
Metallic objects
Effective maximum detecting
distance (with standard target)
1.5 mm (0.06 in)
±15%
2 mm (0.08 in)
±10%
5 mm (0.20 in)
±10%
10 mm (0.39 in)
±10%
Usable detecting range
(with standard target)
0 to 1.2 mm
(0 to 0.05 in)
0 to 1.6 mm
(0 to 0.06 in)
0 to 4 mm
(0 to 0.16 in)
0 to 8 mm
(0 to 0.31 in)
Standard target size
(mild steel, L x W x H)
8 x 8 x 1 mm
(0.31 x 0.31 x 0.04 in)
12 x 12 x 1 mm
(0.47 x 0.47 x 0.04 in)
18 x 18 x 1 mm
(0.71 x 0.71 x 0.04 in)
30 x 30 x 1 mm
(1.18 x 1.18 x 0.04 in)
Differential travel
10% max. of effective max. detecting distance
Type
SCR-NO (E2F-XꢀꢀY1-ꢀꢀ-ꢀꢀ)
AC
solid-
state
Control
output
SCR-NC (E2F-XꢀꢀY2-ꢀꢀ-ꢀꢀ)
Max. load
100 mA
300 mA for E2F-XꢀꢀYꢀ-US and
E2F-XꢀꢀYꢀ-53-US at -25°C to 70°C
(-13°F to 158°F)
500 mA for E2F-XꢀꢀYꢀ-US at -25°C to 55°C
(-13°F to 131°F)
Min. load
5 mA
Max. off-state
leakage current
1.7 mA at 200 VAC
1.7 mA at 200 VAC (E2F-XꢀꢀYꢀ-US)
1.5 mA at 200 VAC (E2F-XꢀꢀYꢀ-53-US)
Max. on-state
voltage drop
See "Residual Load Voltage Characteristics" graph in Engineering Data.
Response frequency
25 Hz
Circuit
protection
Ouput short-
circuit
Not provided
Provided on E2F-XꢀꢀYꢀ-53-US types only;
manual resetting type
Weld field
immunity
Not provided
RFI immunity
Not provided
Indicators
Materials
Output Operation (red LED)
Polyarylate
Housing
Sensing face
Cable sheath
Polyarylate
Polyvinal Chloride
Mounting
Two plastic M8 nuts
included. Bracket
Y92E-B8 optional.
Two plastic M12 nuts
included. Bracket
Y92E-B12 optional.
Two plastic M18 nuts
included. Bracket
Y92E-B18 optional.
Two plastic M30 nuts
included. Bracket
Y92E-B30 optional.
Connections
Prewired
2-conductor cable, 2 m (6.56 ft) length
Weight with cable
Approx. 40 g
(1.4 oz)
Approx. 50 g
(1.8 oz)
Approx. 130 g
(4.6 oz)
Approx. 170 g
(6.0 oz)
Enclosure
ratings
UL
—
1
NEMA
IEC 144
UL
1, 3, 4, 6, 12, 13
IP68
—
Approvals
Recognized, File number E76675
Certified, FIle number LR45951
CSA
—
Ambient operating temperature
-25°C to 70°C (-13° to 158°F)
10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Approx. 100 G
Vibration
Shock
5
E2F
E2F
Operation
■ OUTPUT CIRCUIT DIAGRAM AND TIMING CHARTS
DC 3-Wire Models
With Short-Circuit Protection
AC 2-Wire Models
6
E2F-X1R5
ꢀ
ꢀ
, E2F-X2
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
E2F-X1R5
ꢀ
ꢀ
, E2F-X2
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
E2F
E2F
Engineering Data
Operating Range
Shielded M8 and M12 Size Sensors
Shielded M18 and M30 Size Sensors
E2F-X5 , E2F-X10
Detecting Distance vs. Size and Material of Target
Shielded M8 and M12 Size Sensors
Shielded M18 and M30 Size Sensors
E2F-X5 , E2F-X10
Note: If the target is a nonferrous metal, the operating distance of the proximity sensor decreases. However, with a piece of foil measuring
about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity
sensor cannot detect extremely thin evaporated films and non-conductive targets.
7
E2F
E2F
Residual Load Voltage Characteristics
Leakage Current Characteristics
8
E2F
E2F
Dimensions
Unit: mm (inch)
■ SENSORS
DC 3-Wire Models
AC-2-Wire Models
9
E2F
E2F
AC Shielded M18 Size without
short-circuit protection
AC Shielded M18 Size with
short-circuit protection
E2F-X5Y
ꢀ
-US
E2F-X5Y -53-US
ꢀ
■ OPTIONAL MOUNTING BRACKETS
Applicable sensor
models
Part
number
Drawing dimensions
A
B
C
D
8
E
F
Y92E-B8 18 ±0.2
10
18
28
M4 x 20 E2F-X1R5E(F)(Y)ꢀ
(0.71 ±0.01) (0.39) (0.71) (0.31) (1.10) bolt
max.
dia.
max.
Y92E-B12 24 ±0.2
12.5
20
12
37
M4 x 25 E2F-X2E(F)(Y)ꢀ
(0.94 ±0.01) (0.49) (0.79) (0.47) (1.46) bolt
max.
dia.
max.
Y92E-B18 32 ±0.2
17
30
18
47
M5 x 32 E2F-X5E(F)(Y)ꢀ-US,
(1.26 ±0.01) (0.67) (1.18) (0.71) (1.85) bolt
E2F-X5Yꢀ-53-US
max.
dia.
max.
Y92E-B30 45 ±0.2
17
50
30
60
M5 x 50 E2F-X10E(F)(Y)ꢀ-US,
(1.77 ±0.01) (0.67) (1.97) (1.18) (2.36) bolt
max. dia. max.
E2F-X10Yꢀ-53-US
10
E2F
E2F
Precautions
■ TIGHTENING FORCE
Do not exceed the torque listed in the
table provided when tightening the
mounting nuts.
Part number
Maximum torque
kg-cm in-lbs
E2F-X1R5ꢀꢀ
E2F-X2ꢀꢀ
8
8
6.93
6.93
E2F-X5ꢀꢀ-(53)-US 20
E2F-X10ꢀꢀ-(53)-US 20
17.32
17.32
■ EFFECTS OF SURROUNDING METALS
l
When mounting a proximity sensor flush with a metallic
panel, be sure to provide a minimum distance as shown
in the table below. This prevents the sensor from being
effected by metallic objects other than the target.
φd
D
m
Sensor model
Drawing
dimension
E2F-X1R5ꢀꢀ
E2F-X2ꢀꢀ
E2F-X5ꢀꢀ
E2F-X10ꢀꢀ
mm
inch
0
mm
inch
0
mm
inch
mm
inch
0
l
0
0
0
0
0
d (dia.)
8
0.31
0
12
0
0.47
0
18
0
0.71
0
30
0
1.18
0
D
0
m
4.5
0.18
8
0.31
20
0.79
40
1.57
■ MUTUAL INTERFERENCE
To prevent mutual interference between two sensors, be
sure to space the two sensors at a distance greater than
that shown in the table below.
B
A
Sensor model
Drawing
dimension
E2F-X1R5ꢀꢀ
E2F-X2ꢀꢀ
E2F-X5ꢀꢀ
E2F-X10ꢀꢀ
mm
inch
0.79
0.59
mm
inch
1.18
0.79
mm
inch
1.97
1.38
mm
100
70
inch
3.94
2.76
A
B
20
30
50
15
20
35
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
OMRON ON-LINE
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
Global - http://www.omron.com
USA - http://www.omron.com/oei
Canada - http://www.omron.com/oci
1-800-55-OMRON
416-286-6465
Cat. No. CEDSAX4
11/01
Specifications subject to change without notice.
Printed in the U.S.A.
相关型号:
©2020 ICPDF网 联系我们和版权申明