E2EL-C2E1-DS2M [OMRON]
Cylindrical Proximity Sensor; 圆柱形接近传感器型号: | E2EL-C2E1-DS2M |
厂家: | OMRON ELECTRONICS LLC |
描述: | Cylindrical Proximity Sensor |
文件: | 总12页 (文件大小:180K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Cylindrical Proximity Sensor E2EL
A new series of easy–to–use models for
standard– and double–distance
Stainless steel and brass housing
Two housing length for each type
Pre–wired and Plug–in connector types
Short–circuit protection and reverse pola-
rity protection
Ordering Information
Cable types
Brass housing
Output
Diameter
Length
Mounting
Sensing
Distance
NPN / NO
E2EL–C1R5E1 2M
E2EL–C2ME1 2M
NPN / NC
E2EL–C1R5E2 2M
E2EL–C2ME2 2M
PNP / NO
PNP / NC
E2EL–C1R5F2 2M
E2EL–C2MF2 2M
∅6,5
30 mm
32 mm
45 mm
47 mm
30 mm
32 mm
45 mm
47 mm
41 mm
Shielded
1,5 mm
E2EL–C1R5F1 2M
E2EL–C2MF1 2M
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
E2EL–C1R5E1–L 2M E2EL–C1R5E2–L 2M E2EL–C1R5F1–L 2M E2EL–C1R5F2–L 2M
E2EL–C2ME1–L 2M
E2EL–X1R5E1 2M
E2EL–X2ME1 2M
E2EL–C2ME2–L 2M
E2EL–X1R5E2 2M
E2EL–X2ME2 2M
E2EL–C2MF1–L 2M
E2EL–X1R5F1 2M
E2EL–X2MF1 2M
E2EL–C2MF2–L 2M
E2EL–X1R5F2 2M
E2EL–X2MF2 2M
M8
E2EL–X1R5E1–L 2M E2EL–X1R5E2–L 2M E2EL–X1R5F1–L 2M E2EL–X1R5F2–L 2M
E2EL–X2ME1–L 2M
E2EL–X2E1 2M
E2EL–X2ME2–L 2M
E2EL–X2E2 2M
E2EL–X2MF1–L 2M
E2EL–X2F1 2M
E2EL–X2MF2–L 2M
E2EL–X2F2 2M
M12
Shielded
Shielded
2,0 mm
4,0 mm
E2EL–X4E1–D 2M
E2EL–X4ME1 2M
E2EL–X2E1–L 2M
E2EL–X4E1–DL 2M
E2EL–X4ME1–L 2M
E2EL–X5E1 2M
E2EL–X4E2–D 2M
E2EL–X4ME2 2M
E2EL–X2E2–L 2M
E2EL–X4E2–DL 2M
E2EL–X4ME2–L 2M
E2EL–X5E2 2M
E2EL–X4F1–D 2M
E2EL–X4MF1 2M
E2EL–X2F1–L 2M
E2EL–X4F1–DL 2M
E2EL–X4MF1–L 2M
E2EL–X5F1 2M
E2EL–X4F2–D 2M
E2EL–X4MF2 2M
E2EL–X2F2–L 2M
E2EL–X4F2–DL 2M
E2EL–X4MF2–L 2M
E2EL–X5F2 2M
Non–shielded 4,0 mm
53 mm
40 mm
73 mm
Shielded
Shielded
2,0 mm
4,0 mm
Non–shielded 4,0 mm
M18
M30
Shielded
Shielded
5,0 mm
8,0 mm
E2EL–X8E1–D 2M
E2EL–X8ME1 2M
E2EL–X5E1–L 2M
E2EL–X8E1–DL 2M
E2EL–X8ME1–L 2M
E2EL–X10E1 2M
E2EL–X15ME1 2M
E2EL–X10E1–L 2M
E2EL–X8E2–D 2M
E2EL–X8ME2 2M
E2EL–X5E2–L 2M
E2EL–X8E2–DL 2M
E2EL–X8ME2–L 2M
E2EL–X10E2 2M
E2EL–X15ME2 2M
E2EL–X10E2–L 2M
E2EL–X8F1–D 2M
E2EL–X8MF1 2M
E2EL–X5F1–L 2M
E2EL–X8F1–DL 2M
E2EL–X8MF1–L 2M
E2EL–X10F1 2M
E2EL–X15MF1 2M
E2EL–X10F1–L 2M
E2EL–X8F2–D 2M
E2EL–X8MF2 2M
E2EL–X5F2–L 2M
E2EL–X8F2–DL 2M
E2EL–X8MF2–L 2M
E2EL–X10F2 2M
E2EL–X15MF2 2M
E2EL–X10F2–L 2M
Non–shielded 8,0 mm
Shielded
Shielded
5,0 mm
8,0 mm
Non–shielded 8,0 mm
Shielded 10,0 mm
Non–shielded 15,0 mm
Shielded 10,0 mm
Non–shielded 15,0 mm
40 mm
80 mm
E2EL–X15ME1–L 2M E2EL–X15ME2–L 2M E2EL–X15MF1–L 2M E2EL–X15MF2–L 2M
1
E2EL
E2EL
Stainless steel housing
Output
Diameter
∅6,5
M8
Length
Mounting
Sensing
Distance
NPN / NO
NPN / NC
E2EL–C2E2–DS 2M
PNP / NO
PNP / NC
E2EL–C2F2–DS 2M
30 mm
45 mm
30 mm
45 mm
41 mm
53 mm
40 mm
73 mm
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
Shielded
2,0 mm
2,0 mm
2,0 mm
2,0 mm
4,0 mm
4,0 mm
8,0 mm
8,0 mm
E2EL–C2E1–DS 2M
E2EL–C2F1–DS 2M
E2EL–C2E1–DSL 2M E2EL–C2E2–DSL 2M E2EL–C2F1–DSL 2M E2EL–C2F2–DSL 2M
E2EL–X2E1–DS 2M E2EL–X2E2–DS 2M E2EL–X2F1–DS 2M E2EL–X2F2–DS 2M
E2EL–X2E1–DSL 2M E2EL–X2E2–DSL 2M E2EL–X2F1–DSL 2M E2EL–X2F2–DSL 2M
E2EL–X4E1–DS 2M E2EL–X4E2–DS 2M E2EL–X4F1–DS 2M E2EL–X4F2–DS 2M
E2EL–X4E1–DSL 2M E2EL–X4E2–DSL 2M E2EL–X4F1–DSL 2M E2EL–X4F2–DSL 2M
E2EL–X8E1–DS 2M E2EL–X8E2–DS 2M E2EL–X8F1–DS 2M E2EL–X8F2–DS 2M
M12
M18
E2EL–X8E1–DSL 2M E2EL–X8E2–DSL 2M E2EL–X8F1–DSL 2M E2EL–X8F2–DSL 2M
Plug types
Brass housing
Output
Diameter /
Length
Mounting
Sensing
Distance
Connection
NPN / NO
E2EL–C1R5E1–M3
E2EL–C2ME1–M3
NPN / NC
E2EL–C1R5E2–M3
E2EL–C2ME2–M3
PNP / NO
E2EL–C1R5F1–M3
E2EL–C2MF1–M3
PNP / NC
E2EL–C1R5F2–M3
E2EL–C2MF2–M3
∅6,5 /
45 mm
47 mm
54 mm
56 mm
45 mm
47 mm
54 mm
56 mm
44 mm
Shielded
1,5 mm
Plug M8
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
Shielded 1,5 mm
Non–shielded 2,0 mm
E2EL–C1R5E1–M3L E2EL–C1R5E2–M3L E2EL–C1R5F1–M3L E2EL–C1R5F2–M3L
E2EL–C2ME1–M3L
E2EL–X1R5E1–M3
E2EL–X2ME1–M3
E2EL–C2ME2–M3L
E2EL–X1R5E2–M3
E2EL–X2ME2–M3
E2EL–C2MF1–M3L
E2EL–X1R5F1–M3
E2EL–X2MF1–M3
E2EL–C2MF2–M3L
E2EL–X1R5F2–M3
E2EL–X2MF2–M3
M8 /
Plug M8
E2EL–X1R5E1–M3L E2EL–X1R5E2–M3L E2EL–X1R5F1–M3L E2EL–X1R5F2–M3L
E2EL–X2ME1–M3L
E2EL–X1R5E1–M1
E2EL–X2ME1–M1
E2EL–X2ME2–M3L
E2EL–X1R5E2–M1
E2EL–X2ME2–M1
E2EL–X2MF1–M3L
E2EL–X1R5F1–M1
E2EL–X2MF1–M1
E2EL–X2MF2–M3L
E2EL–X1R5F2–M1
E2EL–X2MF2–M1
M8 /
Plug M12 46 mm
60 mm
E2EL–X1R5E1–M1L E2EL–X1R5E2–M1L E2EL–X1R5F1–M1L E2EL–X1R5F2–M1L
62 mm
E2EL–X2ME1–M1L
E2EL–X2E1–M1
E2EL–X2ME2–M1L
E2EL–X2E2–M1
E2EL–X2MF1–M1L
E2EL–X2F1–M1
E2EL–X2MF2–M1L
E2EL–X2F2–M1
M12 /
49 mm
60 mm
53 mm
80 mm
Shielded
Shielded
2,0 mm
4,0 mm
Plug M12
E2EL–X4E1–DM1
E2EL–X4ME1–M1
E2EL–X2E1–M1L
E2EL–X4E1–DM1L
E2EL–X4ME1–M1L
E2EL–X5E1–M1
E2EL–X4E2–DM1
E2EL–X4ME2–M1
E2EL–X2E2–M1L
E2EL–X4E2–DM1L
E2EL–X4ME2–M1L
E2EL–X5E2–M1
E2EL–X4F1–DM1
E2EL–X4MF1–M1
E2EL–X2F1–M1L
E2EL–X4F1–DM1L
E2EL–X4MF1–M1L
E2EL–X5F1–M1
E2EL–X4F2–DM1
E2EL–X4MF2–M1
E2EL–X2F2–M1L
E2EL–X4F2–DM1L
E2EL–X4MF2–M1L
E2EL–X5F2–M1
Non–shielded 4,0 mm
Shielded
Shielded
2,0 mm
4,0 mm
Non–shielded 4,0 mm
M18 /
Shielded
Shielded
5,0 mm
8,0 mm
Plug M12
E2EL–X8E1–DM1
E2EL–X8ME1–M1
E2EL–X5E1–M1L
E2EL–X8E1–DM1L
E2EL–X8ME1–M1L
E2EL–X10E1–M1
E2EL–X15ME1–M1
E2EL–X10E1–M1L
E2EL–X8E2–DM1
E2EL–X8ME2–M1
E2EL–X5E2–M1L
E2EL–X8E2–DM1L
E2EL–X8ME2–M1L
E2EL–X10E2–M1
E2EL–X15ME2–M1
E2EL–X10E2–M1L
E2EL–X8F1–DM1
E2EL–X8MF1–M1
E2EL–X5F1–M1L
E2EL–X8F1–DM1L
E2EL–X8MF1–M1L
E2EL–X10F1–M1
E2EL–X15MF1–M1
E2EL–X10F1–M1L
E2EL–X8F2–DM1
E2EL–X8MF2–M1
E2EL–X5F2–M1L
E2EL–X8F2–DM1L
E2EL–X8MF2–M1L
E2EL–X10F2–M1
E2EL–X15MF2–M1
E2EL–X10F2–M1L
Non–shielded 8,0 mm
Shielded
Shielded
5,0 mm
8,0 mm
Non–shielded 8,0 mm
Shielded 10,0 mm
Non–shielded 15,0 mm
Shielded 10,0 mm
Non–shielded 15,0 mm
M30 /
55 mm
80 mm
Plug M12
E2EL–X15ME1–M1L E2EL–X15ME2–M1L E2EL–X15MF1–M1L E2EL–X15MF2–M1L
Stainless steel housing
Output
Diameter /
Connection
Length
Mounting
Sensing
Distance
NPN / NO
NPN / NC
PNP / NO
PNP / NC
M8 /Plug 54 mm
Shielded
2,0 mm
E2EL–X2E1–DM3SL E2EL–X2E2–DM3SL E2EL–X2F1–DM3SL E2EL–X2F2–DM3SL
M8
M12 /
Plug M12 60 mm
M18 / 53 mm
Plug M12 80 mm
49 mm
Shielded
Shielded
Shielded
Shielded
4,0 mm
4,0 mm
8,0 mm
8,0 mm
E2EL–X4E1–DM1S
E2EL–X4E1–DM1SL E2EL–X4E2–DM1SL E2EL–X4F1–DM1SL E2EL–X4F2–DM1SL
E2EL–X8E1–DM1S E2EL–X8E2–DM1S E2EL–X8F1–DM1S E2EL–X8F2–DM1S
E2EL–X8E1–DM1SL E2EL–X8E2–DM1SL E2EL–X8F1–DM1SL E2EL–X8F2–DM1SL
E2EL–X4E2–DM1S
E2EL–X4F1–DM1S
E2EL–X4F2–DM1S
2
E2EL
E2EL
Specifications
Brass type
Type
∅6,5
M8
M12
M18
M30
Operating voltage
Rated supply voltage
Current consumption
Sensing object
10 to 35 VDC
24 VDC
max. 15 mA at 24 VDC
Ferrous metals
Mounting ((s)hielded,
s
n
s
n
s
s
n
s
s
n
s
n
(n)on–shielded) (see note 1)
Operating distance in mm
1,5
2,0
1,5
2,0
2,0
4,0
4,0
5,0
8,0
8,0
10,0
15,0
Tolerance of operating distance
10%
6,5x6,5x1
Standard target size in mm
(L x W x H in mm, FE 37)
8x8x1
12x12x1
18x18x1 24x24x1
30x30x1 45x45x1
Differential travel
1 % ... 15 % of operating distance
5,0 5,0 2,0
Max. response frequency in kHz
Control output Type
0,6
1,0
0,5
0,3
0,5
0,25
0,15
E2EL–... E1 type: NPN–NO
E2 type: NPN–NC
F1 type: PNP–NO
F2 type: PNP–NC
Max–Load
Max–on–state
200 mA
2,5 VDC (at 200mA load current and with 2 m cable)
Voltage drop
Circuit protection
Indicator
Reverse polarity, output short–circuit
Operating indicator (yellow LED)
Operating: –25° to 70°C
Ambient temperature
Humidity
35 to 95 % RH
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
10 % max. of Sn at 23°C in temperature range of –25° to 70°C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947–5–2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Shock
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions
resistance
Enclosure
rating
IP 67 (EN 60947–1)
2
Connection
(see note 2)
Pre–wired
Connector
2 m PVC–cable, 3 x
0,14 mm@
2 m PVC–cable, 3 x 0,25 mm
2m PVC–cable, 3 x
0,5 mm
2
M8 plug
M8 plug
M12 plug
M12 plug
Weight in g
Material
Pre–wired
long
45
50
48
15
13
75
70
25
20
115
100
60
260
200
155
110
short
43
Connector long
short
10
8
50
Case
Brass
PBTP
Sensing face
Note: 1. For detailed mounting instruction please refer to page 11.
2. PUR cable and different length on request.
3
E2EL
E2EL
Stainless steel type
Type
∅6,5
10 to 35 VDC
24 VDC
M8
M12
M18
Operating voltage
Rated supply voltage
Current consumption
Mounting (see note 1)
Sensing object
max. 15 mA at 24 VDC
Shielded
Ferrous metals
2,0
Operating distance in mm
Tolerance of operating distance
2,0
4,0
8,0
10%
Standard target size
6,5x6,5x1
8x8x1
12x12x1
24x24x1
(L x W x H in mm, FE 37)
Differential
travel
1 % ... 15 % of operating distance
Max. response frequency in kHz
Control output Type
4,0 4,0
0,6
0,25
E2EL–... E1 type: NPN–NO
E2 type: NPN–NC
F1 type: PNP–NO
F2 type: PNP–NC
Max–Load
200 mA
Max–on–state
Voltage drop
2,5 VDC (at 200mA load current and with 2 m cable)
Circuit protection
Indicator
Reverse polarity, output short–circuit
Operating indicator (yellow LED)
Operating: –25° to 70°C
Ambient temperature
Humidity
35 to 95 % RH
Influence of temperature
Dielectric strength
Electromagnetic compatibility EMC
Vibration resistance
Shock resistance
10 % max. of Sn at 23°C in temperature range of –25° to 70°C
1.500 VAC, 50/60 Hz for 1 min. between current carry parts and case
EN 60947–5–2
Destruction: 10 to 70 Hz, 1,5 mm double amplitude for 1 hour each in X, Y and Z directions
Destruction: 300 m/s@ (approx. 30 G) for 6 times each in X, Y and Z directions
IP 67 (EN 60947–1)
Enclosure
rating
2
Connection
(see note 2)
Pre–wired
Connector
Pre–wired
2 m PVC–cable, 3 x 0,14 mm@
2 m PVC–cable, 3 x 0,25 mm
M12 plug
–
M8 plug
Weight in g
long
45
43
–
50
48
10
–
75
70
25
20
120
105
65
short
Connector long
short
–
55
Material
Case
stainless steel 1.4305 / AISI 303
PBTP
Sensing face
Note: 1. For detailed mounting instruction please refer to page 11.
2. PUR cable and different length on request.
4
E2EL
E2EL
Engineering Data
Standardized characteristic for lateral approach
1,2
axial
standard target
approach
1
0,8
0,6
0,4
0,2
0
’switch–on’ curve
switch–off’ curve
’
lateral approach
on
off
–1
–0,8
–0,6
–0,4
–0,2
0
0,2
0,4
0,6
0,8
1
lateral distance related to radius of ’active surface’ (r/ract
)
Output Circuit Diagram and Timing Chart
E2EL–XjEj
NPN Output
E2EL-XjFj
PNP Output
Brown 1
Brown 1
Load
4,7 kΩ
Black 4 (or 2)
Load
Main
circuit
Main
circuit
Black 4 (or 2)
Blue 3
4,7 kΩ
0 V
Blue 3
E2EL–XjEj
NPN Output
E2EL–XjFj
PNP Output
NC
NO
NC
NO
Yes
No
Sensing object
Sensing object
Yellow indicator
Control output
Yes
No
Lit
Lit
Yellow indicator
Control output
Not lit
ON
Not lit
ON
OFF
OFF
5
E2EL
E2EL
Pin Arrangement at Connector Types
1. Connector M8 (viewed to plug pins)
Output
+
–
2. Connector M12 (viewed to plug pins)
NO
NC
2 free
1 (+)
2 Output
1 (+)
3(–)
3(–)
4 Output
4 free
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions. Values in parentheses () are cumulative values and
may exceed tolerance of 0.4 mm.
3. The square j in the models represents the output configuration. Refer to Ordering Information.
Cable Types
E2EL–C1jR5 2M, E2EL–C2j–DS 2M
E2EL–C2Mj 2M
E2EL–C1R5j–L 2M, E2EL–C2j–DSL 2M
E2EL–C2Mj–L 2M
E2EL–X1R5j 2M, E2EL–X2j–DS 2M
E2EL–X2Mj 2M
E2EL–X1R5j–L 2M, E2EL–X2j–DSL 2M
E2EL–X2Mj–L 2M
6
E2EL
E2EL
E2EL–X2j 2M, E2EL–X4j–D 2M, E2EL–X4j–DS 2M
E2EL–X4Mj 2M
E2EL–X2j–L 2M, E2EL–X4j–DL 2M, E2EL–X4j–DSL 2M
E2EL–X4Mj–L 2M
E2EL–X5j 2M, E2EL–X8j–D 2M, E2EL–X8j–DS 2M
E2EL–X5j–L 2M, E2EL–X8j–DL 2M, E2EL–X8j–DSL 2M
E2EL–X10j 2M
E2EL–X8Mj 2M
E2EL–X8Mj–L 2M
E2EL–X15Mj 2M
E2EL–X10j–L 2M
E2EL–X15Mj–L 2M
7
E2EL
E2EL
Plug Types
E2EL–C1R5j–M3
E2EL–C2Mj–M3
E2EL–C1R5j–M3L
E2EL–C2Mj–M3L
E2EL–X1R5j–M3
E2EL–X2Mj–M3
E2EL–X1R5j–M3L, E2EL–X2jDM3S
E2EL–X2Mj–M3L
E2EL–X1R5j–M1
E2EL–X2Mj–M1
E2EL–X2Mj–M1L
E2EL–X4Mj–M1
E2EL–X1R5j–M1L
E2EL–X2j–M1, E2EL–X4j–DM1, E2EL–X4j–DM1S
8
E2EL
E2EL
E2EL–X2j–M1L, E2EL–X4j–DM1L, E2EL–X4j–DM1SL
E2EL–X4Mj–M1L
E2EL–X5j–M1, E2EL–X8j–DM1, E2EL–X8j–DM1S
E2EL–X8Mj–M1
E2EL–X5j–M1L, E2EL–X8j–DM1L, E2EL–X8j–DM1SL
E2EL–X8Mj–M1L
E2EL–X10j–M1
E2EL–X15Mj–M1
E2EL–X10j–M1L
E2EL–X15Mj–M1L
9
E2EL
E2EL
Installation
Caution
Item
Examples
Power Supply
Do not impose an excessive voltage on the E2EL, otherwise it
may explode or burn.
Do not impose 24 VAC on any E2EL model, otherwise it may
explode or burn.
Load short–circuit
Do not short–circuit the load, or the E2EL may explode or burn.
The E2EL’s short–circuit protection function is valid, if the polarity
of the supply voltage imposed is incorrect and within the rated
voltage range.
Wiring
Be sure to wire the E2EL and load correctly, otherwise it may
explode or burn.
Correct Use
Installation
If there a power or high–tension line near the cord of the Proximity
Sensor, wire the cord through an independent metal conduit to pre-
vent against Proximity Sensor damage or malfunctioning.
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
issupplied. IfpowersuppliesareconnectedtotheProximitySensor
andloadrespectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.
Core Tractive Force
Do not pull cords with the tractive force exceeding the following:
pull force (N) = 20 x cable diameter ( mm)
Power OFF
Mounting
TheProximitySensormayoutputapulsesignalwhenitisturnedoff.
Therefore, it is recommended to turn off the load before turning off
the Proximity Sensor.
The Proximity Sensor must not be subjected to excessive shock
with a ha mmer when it is installed, otherwise the Proximity Sensor
may be damaged or lose the water–resistivity.
Power Supply Transformer
Environment
Water–Resistivity
When using a DC power supply, make sure that the DC power sup-
plyhasaninsulatedtransformer. DonotuseaDCpowersupplywith
an auto–transformer.
Do not use the ProximitySensorunderwater, outdoorsorintherain.
Sensing Object
Operating Environment
Metal Coating:
Be sure to use the Proximity Sensor within operating ambient tem-
perature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Prox-
imity Sensor from water or soluble machining oil is reco mmended
so that its reliability and life expectancy can be maintained. Do not
use the Proximity Sensor in an environment with chemical gas (e.
G., strong alkaline or acid gases including nitric, chromic, and con-
centrated sulfuric acid gases).
The sensing distance of the Proximity Sensor vary with the metal
coating on sensing objects.
Wiring
High–tension Lines
Wiring through Metal Conduit
10
E2EL
E2EL
Item
Examples
Item
AND
The Sensors connected together must satisfy the
following conditions:
(serial
connection)
i + (N–1) x i = Upper–limit of control output of each
Sensor
L
V
S
– N x V = Load operating voltage
R
N =
No. of Sensors
V
R
V
S
=
=
Residual voltage of each Sensor
Supply voltage
i =
i =
Current consumption of the Sensor
Load current
L
If the MY Relay, which operate at 24 VDC, is used as a
load for example, a maximum of two Proximity Sensors
can be connected to the load.
OR
The number of Sensors connected in parallel varies with
the Proximity Sensor model.
(parallel
connection)
Effects of Surrounding Metal
Shielded types:
Non–shielded types:
Shielded types allow direct installation on metal plates in an em-
bedded manner without performance change. A minimum distance
Installation of non–shielded types in metal require the minimum di-
stances according to Fig. 3.
of 3s is required between the active surface and a metallic surface
in front of the device. (Fig. 1).
n
w3s w2s
n
n
For SUS shielded types the following minimum distances are re-
quired to avoid performance change (see Fig.2 and table below):
Shielded SUS Types
E2EL–C2j–DS
Free zone
0,5 mm
0,5 mm
1,0 mm
2,0 mm
d
w3d
E2EL–X2j–DS
E2EL–X4j–DjS
E2EL–X8j–DjS
w3s
n
Fig.3: Non–shielded type
Fig.1: Shielded type (except SUS)
Freezone
w3s
n
Fig.2: Shielded SUS type
11
E2EL
E2EL
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
OMRON EUROPE B.V.
Sensor Business Unit
Cat. No. D093-E2-1
Carl–Benz–Straße 4
D–71154 NUFRINGEN (GERMANY)
Phone: +49–70 32–811–0
Fax:
+49–70 32–811–199
12