E2A-M08KS02-M1-C1 [OMRON]
Cylindrical Proximity Sensor; 圆柱形接近传感器型号: | E2A-M08KS02-M1-C1 |
厂家: | OMRON ELECTRONICS LLC |
描述: | Cylindrical Proximity Sensor |
文件: | 总17页 (文件大小:565K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Cylindrical Proximity Sensor
E2A
Safe Mounting with Greater
Sensing Distance
• Ensures a sensing distance approximately 1.5 to 2
times larger than that of any conventional OMRON
Sensor.
• Problems such as the collision of workpieces are
eliminated.
• Full range of standard sizes (M8, M12, M18 and
M30; both long and short barrels)
• Modular construction simplifies customization.
<READ AND UNDERSTAND THIS CATALOG>
Please read and understand this catalog before purchasing
the products. Please consult your OMRON representative if
you have any questions or comments.
Ordering Information
Size
Sensing
distance
Connection
Body
material
Thread length
Output
Operation mode NO
Operation mode NC
(overall length) configuration
M8
Shielded
2.0 mm
Pre-wired
Stainless
steel
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
27 (40)
49 (62)
27 (43)
49 (65)
27 (43)
49 (65)
27 (39)
49 (61)
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
E2A-S08KS02-WP-B1 2M
E2A-S08KS02-WP-C1 2M
E2A-S08LS02-WP-B1 2M
E2A-S08LS02-WP-C1 2M
E2A-S08KS02-M1-B1
E2A-S08KS02-M1-C1
E2A-S08LS02-M1-B1
E2A-S08LS02-M1-C1
E2A-M08KS02-M1-B1
E2A-M08KS02-M1-C1
E2A-M08LS02-M1-B1
E2A-M08LS02-M1-C1
E2A-S08KS02-M5-B1
E2A-S08KS02-M5-C1
E2A-S08LS02-M5-B1
E2A-S08LS02-M5-C1
E2A-S08KN04-WP-B1 2M
E2A-S08KS02-WP-B2 2M
E2A-S08KS02-WP-C2 2M
E2A-S08LS02-WP-B2 2M
E2A-S08LS02-WP-C2 2M
E2A-S08KS02-M1-B2
E2A-S08KS02-M1-C2
E2A-S08LS02-M1-B2
E2A-S08LS02-M1-C2
E2A-M08KS02-M1-B2
E2A-M08KS02-M1-C2
E2A-M08LS02-M1-B2
E2A-M08LS02-M1-C2
E2A-S08KS02-M5-B2
E2A-S08KS02-M5-C2
E2A-S08LS02-M5-B2
E2A-S08LS02-M5-C2
E2A-S08KN04-WP-B2 2M
M12 connector Stainless
steel
Brass
M8 connector (3- Stainless
pin)
steel
Non-shielded
4.0 mm
Pre-wired
Stainless
steel
E2A-S08KN04-WP-C1 2M E2A-S08KN04-WP-C2 2M
E2A-S08LN04-WP-B1 2M
E2A-S08LN04-WP-C1 2M
E2A-S08KN04-M1-B1
E2A-S08KN04-M1-C1
E2A-S08LN04-M1-B1
E2A-S08LN04-M1-C1
E2A-M08KN04-M1-B1
E2A-M08KN04-M1-C1
E2A-M08LN04-M1-B1
E2A-M08LN04-M1-C1
E2A-S08KN04-M5-B1
E2A-S08KN04-M5-C1
E2A-S08LN04-M5-B1
E2A-S08LN04-M5-C1
E2A-S08LN04-WP-B2 2M
E2A-S08LN04-WP-C2 2M
E2A-S08KN04-M1-B2
E2A-S08KN04-M1-C2
E2A-S08LN04-M1-B2
E2A-S08LN04-M1-C2
E2A-M08KN04-M1-B2
E2A-M08KN04-M1-C2
E2A-M08LN04-M1-B2
E2A-M08LN04-M1-C2
E2A-S08KN04-M5-B2
E2A-S08KN04-M5-C2
E2A-S08LN04-M5-B2
E2A-S08LN04-M5-C2
M12 connector Stainless
steel
Brass
M8 connector (3- Stainless
pin)
steel
E2ACylindrical Proximity Sensor
1
Size
Sensing
distance
Connection
Body
material
Thread length
Output
Operation mode NO
Operation mode NC
(overall length) configuration
M12 Shielded
4.0 mm
8.0 mm
8.0 mm
Pre-wired
Brass
34 (50)
56 (72)
34 (48)
56 (70)
34 (50)
56 (72)
34 (48)
56 (70)
39 (59)
61 (81)
39 (53)
61 (75)
39 (59)
61 (81)
39 (53)
61 (75)
44 (64)
66 (86)
44 (58)
66 (80)
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
PNP
NPN
E2A-M12KS04-WP-B1 2M E2A-M12KS04-WP-B2 2M
E2A-M12KS04-WP-C1 2M E2A-M12KS04-WP-C2 2M
E2A-M12LS04-WP-B1 2M
E2A-M12LS04-WP-B2 2M
E2A-M12LS04-WP-C1 2M E2A-M12LS04-WP-C2 2M
M12 connector
Pre-wired
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
Brass
E2A-M12KS04-M1-B1
E2A-M12KS04-M1-C1
E2A-M12LS04-M1-B1
E2A-M12LS04-M1-C1
E2A-M12KS04-M1-B2
E2A-M12KS04-M1-C2
E2A-M12LS04-M1-B2
E2A-M12LS04-M1-C2
Non-shielded
E2A-M12KN08-WP-B1 2M E2A-M12KN08-WP-B2 2M
E2A-M12KN08-WP-C1 2M E2A-M12KN08-WP-C2 2M
E2A-M12LN08-WP-B1 2M E2A-M12LN08-WP-B2 2M
E2A-M12LN08-WP-C1 2M E2A-M12LN08-WP-C2 2M
M12 connector
Pre-wired
E2A-M12KN08-M1-B1
E2A-M12KN08-M1-C1
E2A-M12LN08-M1-B1
E2A-M12LN08-M1-C1
E2A-M12KN08-M1-B2
E2A-M12KN08-M1-C2
E2A-M12LN08-M1-B2
E2A-M12LN08-M1-C2
M18 Shielded
E2A-M18KS08-WP-B1 2M E2A-M18KS08-WP-B2 2M
E2A-M18KS08-WP-C1 2M E2A-M18KS08-WP-C2 2M
E2A-M18LS08-WP-B1 2M
E2A-M18LS08-WP-B2 2M
E2A-M18LS08-WP-C1 2M E2A-M18LS08-WP-C2 2M
M12 connector
E2A-M18KS08-M1-B1
E2A-M18KS08-M1-C1
E2A-M18LS08-M1-B1
E2A-M18LS08-M1-C1
E2A-M18KS08-M1-B2
E2A-M18KS08-M1-C2
E2A-M18LS08-M1-B2
E2A-M18LS08-M1-C2
Non-shielded
16.0 mm Pre-wired
E2A-M18KN16-WP-B1 2M E2A-M18KN16-WP-B2 2M
E2A-M18KN16-WP-C1 2M E2A-M18KN16-WP-C2 2M
E2A-M18LN16-WP-B1 2M E2A-M18LN16-WP-B2 2M
E2A-M18LN16-WP-C1 2M E2A-M18LN16-WP-C2 2M
M12 connector
E2A-M18KN16-M1-B1
E2A-M18KN16-M1-C1
E2A-M18LN16-M1-B1
E2A-M18LN16-M1-C1
E2A-M18KN16-M1-B2
E2A-M18KN16-M1-C2
E2A-M18LN16-M1-B2
E2A-M18LN16-M1-C2
M30 Shielded
15.0 mm Pre-wired
E2A-M30KS15-WP-B1 2M E2A-M30KS15-WP-B2 2M
E2A-M30KS15-WP-C1 2M E2A-M30KS15-WP-C2 2M
E2A-M30LS15-WP-B1 2M
E2A-M30LS15-WP-B2 2M
E2A-M30LS15-WP-C1 2M E2A-M30LS15-WP-C2 2M
M12 connector
E2A-M30KS15-M1-B1
E2A-M30KS15-M1-C1
E2A-M30LS15-M1-B1
E2A-M30LS15-M1-C1
E2A-M30KS15-M1-B2
E2A-M30KS15-M1-C2
E2A-M30LS15-M1-B2
E2A-M30LS15-M1-C2
Non-shielded
20.0 mm Pre-wired
30.0 mm
44 (64)
(See note.)
E2A-M30KN20-WP-B1 2M E2A-M30KN20-WP-B2 2M
E2A-M30KN20-WP-C1 2M E2A-M30KN20-WP-C2 2M
E2A-M30LN30-WP-B1 2M E2A-M30LN30-WP-B2 2M
E2A-M30LN30-WP-C1 2M E2A-M30LN30-WP-C2 2M
66 (86)
20.0 mm M12 connector
30.0 mm
44 (58)
(See note.)
E2A-M30KN20-M1-B1
E2A-M30KN20-M1-C1
E2A-M30LN30-M1-B1
E2A-M30LN30-M1-C1
E2A-M30KN20-M1-B2
E2A-M30KN20-M1-C2
E2A-M30LN30-M1-B2
E2A-M30LN30-M1-C2
66 (80)
Note: M30 non-shielded Models with double sensing distance and short barrels cannot be mounted due to the necessary separation distance from
the surrounding metal. Standard sensing models are thus available.
2
E2A Cylindrical Proximity Sensor
■ Model Number Legend
E2A@-@@@@@-@-@@-@@
1
2
3 4 5 6 7
8
9 10 11 12
Example: E2A-M12LS04-M1-B1
Standard, M12, long barrel, shielded, Sn=4 mm, M12 connector, PNP-NO
Standard, M8, short barrel, non-shielded, Sn=4 mm, pre-wired PVC cable, PNP-NO, cable length=5 m
E2A-M08KN04-WP-B1 5M
1. Basic name
E2A
8. Kind of connection
WP:
M1:
M3:
M5:
Pre-wired, PVC
2. Sensing technology
M12 connector (4-pole)
M8 connector (4-pole)
M8 connector (3-pole)
Blank:
Standard double distance
3. Housing shape and material
M:
S:
Cylindrical, metric threaded, brass
Cylindrical, metric threaded, stainless steel
9. Power source and output
B:
C:
D:
E:
F:
DC, 3-wire, PNP open collector
4. Housing size
DC, 3-wire, NPN open collector
DC, 2-wire
08:
12:
18:
30:
8 mm
12 mm
18 mm
30 mm
DC, 3-wire, NPN voltage output
DC, 3-wire, PNP voltage output
10.Operation mode
5. Barrel length
1:
2:
Normally open (NO)
Normally closed (NC)
K:
Standard length
L:
Long body
11.Specials (e.g., cable material, oscillating frequency)
6. Shield
S:
N:
Shielded
12.Cable length
Non-shielded
Blank:
Connector type
7. Sensing distance
Numeral: Cable type
Numeral: Sensing distance: e.g. 02=2 mm, 16=16 mm
E2ACylindrical Proximity Sensor
3
Specifications
■ DC 3-wire Models
Size
Type
M8
M12
Shielded
Non-shielded
Shielded
Non-shielded
E2A-M08@S02-M1-B1 E2A-M08@N04-M1-B1 E2A-M12@S04-@@-B1 E2A-M12@N08-@@-B1
E2A-M08@S02-M1-B2 E2A-M08@N04-M1-B2 E2A-M12@S04-@@-B2 E2A-M12@N08-@@-B2
E2A-M08@S02-M1-C1 E2A-M08@N04-M1-C1 E2A-M12@S04-@@-C1 E2A-M12@N08-@@-C1
E2A-M08@S02-M1-C2 E2A-M08@N04-M1-C2 E2A-M12@S04-@@-C2 E2A-M12@N08-@@-C2
E2A-S08@S02-@@-B1 E2A-S08@N04-@@-B1
E2A-S08@S02-@@-B2 E2A-S08@N04-@@-B2
E2A-S08@S02-@@-C1 E2A-S08@N04-@@-C1
Item
Sensing distance
E2A-S08@S02-@@-C2 E2A-S08@N04-@@-C2
2 mm ± 10%
4 mm ± 10%
4 mm ± 10%
8 mm ± 10%
Setting distance
0 to 1.6 mm
0 to 3.2 mm
0 to 3.2 mm
0 to 6.4 mm
Differential travel
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Target
Standard target (mild steel ST37)
Response frequency (See note 1.)
8×8×1 mm
12×12×1 mm
12×12×1 mm
24×24×1 mm
1,500 Hz
1,000 Hz
1,000 Hz
800 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 3-wire)
Output type
10 mA max.
-B models: PNP open collector
-C models: NPN open collector
Control
output
Load current
(See note 2.)
200 mA max. (32 VDC max.)
Residual voltage
2 V max. (under load current of 200 mA with cable length of 2 m)
Operation indicator (Yellow LED)
Indicator
Operation mode
(with sensing object approaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Power source circuit reverse polarity protection, Output reverse polarity protection, Power source
Surge suppressor, Short-circuit protection
circuit reverse polarity protection, Surge suppres-
sor, Short-circuit protection
Ambient air temperature
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See note 2.)
±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Ambient humidity
Operating: 35% to 95%, Storage: 35% to 95%
Voltage influence
±1% max. of sensing distance in rated voltage range ±15%
Insulation resistance
Dielectric strength
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
500 m/s2, 10 times each in X, Y and Z directions 1,000 m/s2, 10 times each in X, Y and Z directions
Vibration resistance
Shock resistance
Standard and listings (See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight
(packaged)
Pre-wired model
Approx. 65 g
Approx. 85 g
Approx. 35 g
M12 connector model M12 connector models: Approx. 20 g
M8 connector models: Approx. 15 g
Material
Case
Stainless steel or brass-nickel plated
Brass-nickel plated
Sensing surface
Cable
PBT
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between −40°C and −25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.,
3. For USA and CANADA : use class 2 circuit only.
4
E2A Cylindrical Proximity Sensor
■ DC 3-wire Models
Size
M18
M30
Type
Shielded
Non-shielded
Shielded
Non-shielded
Non-shielded
E2A-M18@S08-@@-B1 E2A-M18@N16-@@-B1 E2A-M30@S15-@@-B1 E2A-M30KN20-@@-B1 E2A-M30LN30-@@-B1
E2A-M18@S08-@@-B2 E2A-M18@N16-@@-B2 E2A-M30@S15-@@-B2 E2A-M30KN20-@@-B2 E2A-M30LN30-@@-B2
E2A-M18@S08-@@-C1 E2A-M18@N16-@@-C1 E2A-M30@S15-@@-C1 E2A-M30KN20-@@-C1 E2A-M30LN30-@@-C1
E2A-M18@S08-@@-C2 E2A-M18@N16-@@-C2 E2A-M30@S15-@@-C2 E2A-M30KN20-@@-C2 E2A-M30LN30-@@-C2
Item
Sensing distance
Setting distance
Differential travel
Target
8 mm±10%
16 mm±10%
15 mm±10%
20 mm±10%
30 mm±10%
0 to 6.4 mm
0 to 12.8 mm
0 to 12 mm
0 to 16 mm
0 to 24 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal.)
Standard target
(mild steel ST37)
24×24×1 mm
48×48×1 mm
45×45×1 mm
60×60×1 mm
90×90×1 mm
Response frequency
(See note 1.)
500 Hz
400 Hz
250 Hz
100 Hz
100 Hz
Power supply voltage
(operating voltage range)
12 to 24 VDC. Ripple (p-p): 10% max.
(10 to 32 VDC)
Current consumption (DC 10 mA max.
3-wire)
Output type
-B models: PNP open collector
-C models: NPN open collector
Control Load current (See 200 mA max. (32 VDC max.)
output note 2.)
Residual voltage 2 V max. (under load current of 200 mA with cable length of 2 m)
Indicator
Operation indicator (Yellow LED)
Operation mode
(with sensing object ap-
proaching)
-B1/-C1 models: NO
-B2/-C2 models: NC
For details, refer to the timing charts.
Protection circuit
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit
protection
Ambient air temperature
Operating: −40°C to 70°C, Storage: −40°C to 85°C (with no icing or condensation)
Temperature influence (See ±10% max. of sensing distance at 23°C within temperature range of −25°C to 70°C
note 2.)
±15% max. of sensing distance at 23°C within temperature range of −40°C to 70°C
Operating: 35% to 95%, Storage: 35% to 95%
Ambient humidity
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
±1% max. of sensing distance in rated voltage range ±15%
50 MΩ min. (at 500 VDC) between current carry parts and case
1,000 VAC at 50/60 Hz for 1 min between current carry parts and case
10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions
1,000 m/s2, 10 times each in X, Y and Z directions
Standard and listings
(See note 3.)
IEC60529: IP67, Degree of protection
EN60947-5-2: EMC
Connection method
-WP models: Pre-wired models (Standard length: 2 m)
-M1 models: M12 4-pin connector models
-M5 models: M8 3-pin connector models
Weight Pre-wired model Approx. 160 g
Approx. 280 g
Approx. 200 g
Approx. 280 g
Approx. 200 g
Approx. 370 g
Approx. 260 g
(pack-
M12 connector
model
Approx. 70 g
aged)
Material Case
Brass-nickel plated
Sensing surface PBT
Cable
PVC
Clamping nut
Brass-nickel plated
Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard
target distance between targets, and a setting distance of half the sensing distance.
2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load
current of 100 mA max.
3. For USA and CANADA : use class 2 circuit only.
E2ACylindrical Proximity Sensor
5
Engineering Data
Operating Range (Typical)
Shielded Models
Non-shielded Models
35
18
E2A-M30LN30
E2A-M30@S15
16
14
12
10
8
30
Y
25
X
Y
E2A-M30KN20
X
E2A-M18@S08
E2A-M12@S04
20
15
10
5
E2A-M18@N16
E2A-M12@N08
6
E2A-S08@S02/
E2A-M08@S02
E2A-S08
@
N04/
4
E2A-M08
@
N04
2
0
0
−50 −40 −30 −20 −10
0
10 20 30 40 50
−30
−20
−10
0
10
20
30
Distance Y (mm)
Distance Y (mm)
Influence of Sensing Object Size and Materials
Shielded Models
E2A-S08@S02/M08@S02
E2A-M12@S04
E2A-M18@S08
8.0
5.0
2.5
@d
@d
Iron
t = 1 mm
t = 1 mm
X
7.0
6.0
5.0
4.0
3.0
X
Iron
Iron
2.0
1.5
1.0
0.5
4.0
3.0
2.0
1.0
Stainless steel (SUS303)
Stainless steel
(SUS303)
Stainless steel (SUS303)
Brass
Brass
Brass
Aluminum
Aluminum
Copper
Aluminum
Copper
Copper
@d
2.0
t = 1 mm
X
1.0
0
10
20
30
40
50
60
0
5
10
15
20
25
30
35
0
5
10
15
20
25
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2A-M30@S15
20
@d
t = 1 mm
X
16
12
8
Iron
Stainless steel (SUS303)
Brass
Aluminum
Copper
4
0
10
20
30
40
50
60
70 80
Side length of sensing object d (mm)
6
E2A Cylindrical Proximity Sensor
Non-shielded Models
E2A-S08@N04/M08@N04
E2A-M12@N08
E2A-M18@N16
10
20
5.0
@d
@d
@d
t = 1 mm
X
t = 1 mm
t = 1 mm
X
X
Iron
Iron
Iron
8
6
4
2
16
12
8
4.0
Stainless steel (SUS303)
3.0
2.0
1.0
Stainless steel (SUS303)
Brass
Stainless steel (SUS303)
Brass
Brass
Aluminum
Copper
Aluminum
Copper
Aluminum
Copper
4
0
10
20
30
40
50
0
20
40
60
80
0
10
20
30
40
50
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2A-M30LN30
E2A-M30KN20
35
25
@d
@d
Iron
t = 1 mm
t = 1 mm
X
30
X
Iron
20
15
10
5
25
20
Stainless steel (SUS303)
Brass
Stainless steel (SUS303)
15
Aluminum
Copper
Brass
Aluminum
Copper
10
5
0
20
40
60
80
100
0
20
40
60
80
100
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2ACylindrical Proximity Sensor
7
Operation
■ PNP Output
Operation mode
Model
E2A-@-@-B1
Timing chart
Output circuit
NO
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
Proximity
Sensor
main
Black
Blue
100
0
(%)
(See note 1.)
circuits
Load
ON
0 V
Yellow indicator
Control output
OFF
ON
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
OFF
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
3
1
2
4
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-B2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
)
Sensing
object
Black
(M8 connector:
Proximity
Sensor
main
100
0
(%)
(See note 1.)
circuits
Load
Blue
ON
0 V
Yellow indicator
Control output
OFF
ON
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
OFF
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
3
1
2
4
3
Note 2: Terminal 4 of the M12 connector is not used.
8
E2A Cylindrical Proximity Sensor
■ NPN Output
Operation mode
Model
E2A-@-@-C1
Timing chart
Output circuit
NO
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
Load
Proximity
Sensor
main
(See note 1.)
Black
Blue
100
0
(%)
circuits
0 V
ON
Yellow indicator
Control output
OFF
ON
Note 1: With M8 connector models, there is no output
OFF
reverse polarity protection diode.
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
3
1
2
4
3
Note 2: Terminal 2 of the M12 connector is not used.
NC
E2A-@-@-C2
Non-sensing zone
Sensing zone
Brown
Proximity
Sensor
+V
Sensing
object
Load
Proximity
(See note 1.)
Black
Sensor
main
100
0
(%)
(M8 connector:
)
circuits
Blue
ON
0 V
Yellow indicator
Control output
OFF
ON
Note 1: With M8 connector models, there is no output
reverse polarity protection diode.
OFF
M12 Connector
Pin Arrangement
(See note 2.)
M8 Connector
Pin Arrangement
4
1
3
1
2
4
3
Note 2: Terminal 4 of the M12 connector is not used.
E2ACylindrical Proximity Sensor
9
Dimensions
Note:All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded)
Pre-wired Models (Non-shielded)
E2A-S08KS02-WP-@@
E2A-S08KN04-WP-@@
40
27
40
27
13
6
3
5
3
5
13
6 dia.
M8×1
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12KS04-WP-@@
E2A-M12KN08-WP-@@
50.3
34
50.3
34
17
17
7
4
7
4
7
9.4 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M12×1
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18KS08-WP-@@
E2A-M18KN16-WP-@@
59.5
39
59.5
39
10
4
10
24
4
10
24
15.3 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30KS15-WP-@@
E2A-M30KN20-WP-@@
64.5
44
64.5
44
15
10
36
5
5
10
36
26.6 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M30×1.5
M30×1.5
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
10
E2A Cylindrical Proximity Sensor
E2A-S08LS02-WP-@@
E2A-S08LN04-WP-@@
62
62
49
49
13
6
3
5
3
5
13
6 dia.
M8×1
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
M8×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M12LN08-WP-@@
E2A-M12LS04-WP-@@
72.3
72.3
56
17
17
56
4
7
4
7
7
9.4 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M12×1
M12×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M18LN16-WP-@@
E2A-M18LS08-WP-@@
81.5
61
81.5
61
4
24
10
10
24
10
4
15.3 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
E2A-M30LN30-WP-@@
E2A-M30LS15-WP-@@
86.5
66
86.5
66
36
15
5
10
36
5
10
26.6 dia.
(See note 1.)
(See note 1.)
Indicator (See note 2.)
Indicator (See note 2.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
0.3 mm2; insulator diameter: 1.3 mm); standard length: 2 m
2. Operation indicator (yellow)
Mounting Hole Cutout Dimensions
External diameter
Dimension F (mm)
of Proximity Sensor
+0.5
8.5 dia. 0
M8
M12
M18
M30
12.5 dia.+0.5
0
18.5 dia.+0.5
0
F
30.5 dia.+0.5
0
E2ACylindrical Proximity Sensor
11
M12 Connector Models (Shielded)
M12 Connector Models (Non-shielded)
E2A-S08KN04-M1-@@
E2A-M08KN04-M1-@@
E2A-S08KS02-M1-@@
E2A-M08KS02-M1-@@
43
43
27
27
M12×1
13
5
6
3
3
5
13
M12×1
6 dia.
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
Two, clamping nuts
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M12KS04-M1-@@
E2A-M12KN08-M1-@@
48
48
34
34
17
4
7
17
4
M12×1
M12×1
7
7
9.4 dia.
Indicator (See note.)
Indicator (See note.)
M12×1
M12×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M18KS08-M1-@@
E2A-M18KN16-M1-@@
53
39
53
39
10
10
4
24
24
4
10
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2A-M30KS15-M1-@@
E2A-M30KN20-M1-@@
58
44
58
44
15
5
10
36
10
5
36
M12×1
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
12
E2A Cylindrical Proximity Sensor
E2A-S08LN04-M1-@@
E2A-M08LN04-M1-@@
E2A-S08LS02-M1-@@
E2A-M08LS02-M1-@@
65
65
49
49
M12×1
13
5
6
3
3
5
13
M12×1
6 dia.
Indicator (See note.)
Indicator (See note.)
M8×1
M8×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
70
56
E2A-M12LS04-M1-@@
E2A-M12LN08-M1-@@
70
56
4
17
7
7
4
17
M12×1
7
M12×1
9.4 dia.
Indicator (See note.)
Two, clamping nuts
Indicator (See note.)
M12×1
M12×1
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
75
61
75
61
E2A-M18LS08-M1-@@
E2A-M18LN16-M1-@@
10
10
24
24
4
4
10
M12×1
M12×1
15.3 dia.
Indicator (See note.)
Indicator (See note.)
M18×1
M18×1
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
80
66
E2A-M30LN30-M1-@@
E2A-M30LS15-M1-@@
80
66
10
15
5
36
10
5
36
M12×1
26.6 dia.
Indicator (See note.)
Indicator (See note.)
M30×1.5
Two, clamping nuts
M30×1.5
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
M8 Connector Models (Shielded)
M8 Connector Models (Non-shielded)
E2A-S08KS02-M5-@@
E2A-S08KN04-M5-@@
39
39
27
27
M8×1
5
3
5
13
6
13
3
M8×1
6 dia.
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°)
Two, clamping nuts
Two, clamping nuts
Note: Operation indicator (yellow LED, 4×90°)
E2A-S08LS02-M5-@@
E2A-S08LN04-M5-@@
61
61
49
49
M8×1
5
3
5
13
6
13
3
M8×1
6 dia.
M8×1
M8×1
Note: Operation indicator (yellow LED, 4×90°)
Note: Operation indicator (yellow LED, 4×90°)
E2ACylindrical Proximity Sensor
13
Precautions
Wiring
■ Safety Precautions
Be sure to wire the E2A and load correctly, otherwise it may be dam-
aged.
Power Supply
Do not impose an excessive voltage on the E2A, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Connection with No Load
Be sure to insert loads when wiring. Make sure to connect a proper
load to the E2A in operation, otherwise it may damage internal ele-
ments.
Load Short-circuit
Do not short-circuit the load, or the E2A may be damaged.
Do not expose the product to flammable or explo-
sive gases.
The E2A’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Do not disassemble, repair, or modify the product.
■ Correct Use
Power OFF
Designing
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity Sen-
sor before supplying power to the load.
Power Supply Transformer
When using a DC power supply, make sure that the DC power sup-
ply has an insulated transformer. Do not use a DC power supply with
an auto-transformer.
Effects of Surrounding Metal
When mounting the E2A within a metal panel, ensure that the clear-
ances given in the following table are maintained.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
l
n
m
d dia.
D
m
l
(Unit: mm)
(Unit: mm)
Type
Dimension M8 M12
M18
M30
Type
Dimension
M8
M12
M18
M30
Short Long
barrel barrel
Short Long
barrel barrel
Shielded
l
0
0
0
0
Shielded
A
B
A
B
20
30
60
110
70
(See note (See note 2.)
1.)
15
80
60
20
35
m
d
4.5
---
0
12
---
0
24
27
1.5
27
22
48
70
22
70
45
45
4
Non-
shielded
120
100
200
120
300
200
300
300
D
n
12
12
8
18
15
20
40
15
40
45
30
70
90
30
90
Non-
shielded
l
40
m
d
90
24
12
24
120
40
D
n
120
Note 1. In the case of using the supplied nuts.
If true flash mounting is necessary, apply a free zone of
1.5 mm.
2. In the case of using the supplied nuts.
If true flush mounting is necessary, apply a free zone of
4 mm.
14
E2A Cylindrical Proximity Sensor
Wiring
Maintenance and Inspection
Periodically perform the following checks to ensure stable operation
of the Proximity Sensor over a long period of time.
High-tension Lines
Wiring through Metal Conduit:
1. Check for mounting position, dislocation, looseness, or distortion
If there is a power or high-tension line near the cable of the Proximity
Sensor, wire the cable through an independent metal conduit to pre-
vent against Proximity Sensor damage or malfunctioning.
of the Proximity Sensor and sensing objects.
2. Check for loose wiring and connections, improper contacts, and
line breakage.
3. Check for attachment or accumulation of metal powder or dust.
Cable Extension
Standard cable length is less than 200 m.
4. Check for abnormal temperature conditions and other environ-
mental conditions.
5. Check for proper lighting of indicators (for models with a set indi-
The tractive force is 50 N.
cator.)
Never disassemble or repair the Sensor.
Mounting
The Proximity Sensor must not be subjected to excessive shock with
a hammer when it is installed, otherwise the Proximity Sensor may
be damaged or lose its water-resistivity.
Environment
Water Resistivity
Do not use the Proximity Sensor underwater, outdoors, or in the rain.
Do not tighten the nut with excessive force. A washer must be used
with the nut.
Operating Environment
Be sure to use the Proximity Sensor within its operating ambient
temperature range and do not use the Proximity Sensor outdoors so
that its reliability and life expectancy can be maintained. Although
the Proximity Sensor is water resistive, a cover to protect the Prox-
imity Sensor from water or water-soluble machining oil is recom-
mended so that its reliability and life expectancy can be maintained.
Type
Torque
M8
Stainless steel type 9 N·m
Do not use the Proximity Sensor in an environment with chemical
gas (e.g., strong alkaline or acid gasses including nitric, chromic,
and concentrated sulfuric acid gases).
Brass type
4 N·m
M12
M18
M30
30 N·m
70 N·m
180 N·m
Inrush Current
A load that has a large inrush current (e.g., a lamp or motor) will
damage the Proximity Sensor, in which case connect the load to the
Proximity Sensor through a relay.
E2ACylindrical Proximity Sensor
15
Warranties, Limitations of Liability
■ WARRANTY
■ LIMITATIONS OF LIABILITY
OMRON’s exclusive warranty is that the products are free
from defects in materials and workmanship for a period of
one year (or other period if specified) from date of sale by
OMRON.
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL,
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF
PROFITS OR COMMERCIAL LOSS IN ANY WAY
CONNECTED WITH THE PRODUCTS, WHETHER SUCH
CLAIM IS BASED ON CONTRACT, WARRANTY,
NEGLIGENCE, OR STRICT LIABILITY.
OMRON MAKES NO WARRANTY OR REPRESENTATION,
EXPRESS OR IMPLIED, REGARDING NON-
INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR
PARTICULAR PURPOSE OF THE PRODUCTS. ANY
BUYER OR USER ACKNOWLEDGES THAT THE BUYER
OR USER ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS
OF THEIR INTENDED USE. OMRON DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED.
In no event shall responsibility of OMRON for any act exceed
the individual price of the product on which liability is
asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING
THE PRODUCTS UNLESS OMRON’S ANALYSIS
CONFIRMS THAT THE PRODUCTS WERE PROPERLY
HANDLED, STORED, INSTALLED, AND MAINTAINED AND
NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE,
OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
■ SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any
standards, codes, or regulations that apply to the
combination of products in the customer’s application or use
of the products.
Know and observe all prohibitions of use applicable to this
product.
NEVER USE THE PRODUCTS FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE
HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND
THAT THE OMRON PRODUCT IS PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Take all necessary steps to determine the suitability of the
product for the systems, machines, and equipment with
which it will be used.
Disclaimers
■ CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at
any time based on improvements and other reasons. Consult
with your OMRON representative at any time to confirm
actual specifications of purchased product.
■ DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used
for manufacturing purposes, even when tolerances are
shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. D100-E1-01B
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
Sensing Devices Division H.Q.
Industrial Sensors Division
Shiokoji Horikawa, Shimogyo-ku,
Kyoto, 600-8530 Japan
Tel: (81)75-344-7022/Fax: (81)75-344-7107
16
Cat. No. D100-E1-01B
2008.7
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
相关型号: