D5C-1DP0 [OMRON]

Snap Acting/Limit Switch;
D5C-1DP0
型号: D5C-1DP0
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch

开关
文件: 总8页 (文件大小:553K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Touch Switch  
D5C  
CSM_D5C_DS_E_4_3  
Unique 18-mm-dia. Capacitive Touch  
Switch with Choice of Three Actuators is  
Activated with Only a Very Slight  
Physical Contact  
Only a slight activation force is required, enabling detecting micro  
deflections, thin wires, or thin-plate conductors (e.g., steel or  
stainless).  
Application possible for non-conductors by indirectly connecting to  
ground.  
Instantaneous operation upon contact with extremely limited  
hysteresis for high-precision position detection.  
Diameter of only 18 mm with standard built-in amplifier, operation  
indicator, and sensitivity adjustment.  
Conforms to IEC IP67 *  
Freely replaceable antenna with screw mounting.  
Free attachment to enable changing the antenna shape according to  
the application.  
Be sure to read Safety Precautions on page 6 to 7 and  
Safety Precautions for All Limit Switches.  
* Malfunction may occur if used in locations subject to water or oil.  
Application Examples  
Detection of Incorrectly Set Work  
Press Position Confirmation  
Detection of Bent Drills  
Press  
Press  
D5C  
D5C  
D5C  
D5C  
Detection of Fine Wire or Thin Plate  
Detection of Loose Screws  
Detection of Loose Wires  
Wire  
D5C  
D5C  
D5C  
D5C  
Steel plate  
1.0 mm  
Detection of End of Cloth or Paper  
(Detected with indirect ground)  
Detection of Seams in Cloth or Paper  
(Detected with indirect ground)  
The D5C detects the seam when the antenna  
touches ground pole.  
The D5C detects the end of the paper or cloth  
when the antenna touches ground.  
D5C  
Ground pole  
D5C  
Paper or cloth  
Paper or cloth  
Ground surface  
1
D5C  
Ordering Information  
·Usable by bending tip of antenna.  
·Overtravel of 20 mm max.  
·Ideal for high-accuracy position control.  
·Overtravel of 3.5 mm max.  
Features  
·Any actuator can be attached.  
Free-attachment  
Plunger  
Coil spring  
Actuator  
Item  
Model  
Model  
Model  
D5C-1DS0  
D5C-1AS0  
D5C-00S0  
D5C-1DP0  
D5C-1AP0  
D5C-00P0  
D5C-1DA0  
D5C-1AA0  
D5C-00A0  
DC  
AC  
Supply voltage  
(Power supply)  
Antenna only  
Note: The lead wire is 3 m.  
Specifications  
Ratings and Characteristics  
Type  
DC  
D5C-1D@0  
AC  
Item  
Model  
D5C-1A@0  
Degree of protection  
Mechanical durability  
Equivalent to IP67  
10,000,000 operations min. (at rated overtravel value)  
Supply voltage (operating voltage) 12 to 24 VDC (10 to 30 VDC), (ripple: 10% max.)  
100 to 240 VAC (45 to 264 VAC), 50/60 Hz  
50/60 Hz  
Rated frequency  
---  
Sensitivity setting range  
Current consumption  
30 to 100 pF  
17 mA max.  
---  
Circuit  
Leakage current  
Antenna  
---  
2 mA max.  
1 mA max.  
2 ms max.  
1 mA max.  
Response time  
8 ms max.  
Output current  
200 mA max. (resistive load)  
Insulation resistance  
50 MΩ min. (at 500 VDC) between lead wires and case  
1,000 VAC, 50/60 Hz for 1 min between current-carry- 2,000 VAC, 50/60 Hz for 1 min between current-carry-  
Dielectric strength  
ing metal parts and non-current-carrying metal parts  
ing metal parts and non-current-carrying metal parts  
Rated insulation voltage (Ui)  
1,000 VAC  
Pollution degree  
(operating environment)  
3 (IEC947-5-1)  
Protection against electric shock Class II  
Proof tracking index (PTI)  
Switch category  
175  
D (IEC335)  
Vibration resistance  
Shock resistance  
Ambient temperature  
Ambient humidity  
Weight  
10 to 55 Hz, 1.5-mm double amplitude  
1,000 m/s2 max.  
Operating: 25°C to +70°C (with no icing)  
35% to 95%RH  
Approx. 110 g (in case of D5C-1DS0)  
Approx. 120 g (in case of D5C-1AS0)  
2
D5C  
Engineering Data (Typical Examples)  
Temperature Characteristics of DC Models  
Temperature Characteristics of AC Models  
D5C-1D@0 (24 VDC)  
D5C-1A@0 (100 VAC)  
200  
200  
With sensitivity adjuster  
set to minimum sensitivity  
(
)
150  
150  
100  
50  
With sensitivity adjuster  
set to minimum sensitivity  
(
(
)
100  
50  
0
With sensitivity adjuster  
set to maximum sensitivity  
(
)
With sensitivity adjuster  
set to maximum sensitivity  
)
0
40  
25  
0
40  
70 80  
40  
25  
0
40  
70 80  
Temperature (°C)  
Temperature (°C)  
Voltage Characteristics of DC Model  
Voltage Characteristics of AC Model  
D5C-1D  
@
0
(Ambient temperature: 25  
°
C)  
D5C-1A@0 (Ambient temperature: 25°C  
)
200  
200  
With sensitivity adjuster  
set to minimum sensitivity  
(
)
With sensitivity adjuster  
set to minimum sensitivity  
(
)
150  
100  
50  
150  
100  
50  
With sensitivity adjuster  
set to maximum sensitivity  
With sensitivity adjuster  
set to maximum sensitivity  
(
)
(
)
0
0
10  
20  
30  
100  
200  
300  
Voltage (V)  
Voltage (V)  
Structure and Nomenclature  
Nomenclature  
LED operation  
indicator  
Coil spring actuator  
(Stainless steel)  
O-ring  
Contactor  
Sensitivity adjuster  
Caution label  
O-ring  
Lead wire  
Actuator  
Washer  
Mounting nut  
Filled with glass epoxy  
Case  
Operating Principle  
The limit-type Touch Switch  
vibrates at a high frequency.  
When an object touches the  
antenna...  
...the oscillation circuit  
constant changes,  
oscillation stops...  
...the switching circuit  
operations, and an  
output signal is produced.  
Use the specified  
voltage.  
Feedback circuit  
Antenna  
Detection circuit  
Oscillator  
NOT circuit  
Power supply  
3
D5C  
Series Classification and Features  
D5C-1D@0  
D5C-1A@0  
Power supply 1  
12 to 24 VDC  
Power supply  
100 to 240 VAC  
200 mA max.  
L/R0  
200-mA load max.  
Cosφ = 1  
The D5C by itself can directly switch  
a load if DC power is provided.  
An AC power supply can be detected  
and an AC load can be switched.  
Connections  
Output Circuit Diagram  
The lead wire colors of the D5C have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.  
D5C-1D@0 (DC Model)  
D5C-1A@0 (AC Model)  
Brown (Red)  
Load  
4.7 kΩ  
Brown (White)  
Load  
Switch  
main  
circuit  
Switch  
main  
circuit  
12 to 24 VDC  
Black (White)  
Blue (Black)  
100 to 240 VAC  
Blue (Black)  
Dimensions  
(Unit: mm)  
DC Models  
Coil Spring  
D5C-1DS0  
(162.5)  
61  
56  
(3,000)  
101.5  
51  
*3  
37  
Caution label  
4
14  
4
Overtravel  
16.5 dia.  
16.7 dia.  
4 dia. 7.1 dia.  
29 dia.  
6.5 dia.  
1.2 dia. *1  
M18 × 1  
LED Operation indicator  
* 2  
Two internal lock washers  
Two clamping nuts  
Width: 24  
*1. The stainless steel wire actuator can move in any direction. However,  
limit the overtravel to within 20 mm from the free position. The force that  
pushes the actuator must not exceed 1.96 N.  
(
)
Thickness: 4  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.2 mm2.  
*3 Use after removing the caution label.  
Plunger  
D5C-1DP0  
(85)  
37  
61  
56  
(3,000)  
24  
*3  
Caution label  
4
4
Overtravel  
16.7 dia.  
4 dia. 7.1 dia.  
29 dia.  
16.5 dia. 5 dia.  
*1  
M18 × 1  
Two internal lock washers  
LED Operation indicator  
* 2  
Two clamping nuts  
Width: 24  
*1. The overtravel of the stainless steel plunger is within 3.5 mm.  
Do not apply a force greater than 9.8 N to the plunger.  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.2 mm2.  
(
)
Thickness: 4  
*3 Use after removing the caution label.  
4
D5C  
Free-attachment  
D5C-1DA0  
(89)  
37  
61  
56  
(3,000)  
28  
Lock nut  
*3  
14  
4
Caution label  
4
M4 × 0.7 *1  
16.7 dia.  
4 dia. 7.1 dia.  
29 dia.  
16.5 dia.  
Self-locking nut  
* 2  
M18 × 1  
LED Operation indicator  
Two flat washers  
Two clamping nuts  
Width: 24  
Two internal  
lock washers  
*1. Limit the total length of actuator wire to 1 m or less.  
Thickness: 4  
When mounting the Switch to a metal plate, do not exceed an area of 200 cm2.  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.2 mm2.  
(
)
*3 Use after removing the caution label.  
AC Models  
Coil Spring  
D5C-1AS0  
(177.5)  
76  
71  
(3,000)  
101.5  
51  
*3  
52  
Caution label  
14  
4
4
Overtravel  
16.7 dia.  
4 dia. 7.1 dia.  
16.5 dia. 6.5 dia.  
29 dia.  
1.2 dia. *1  
M18 × 1  
LED Operation indicator  
* 2  
Two internal lock washers  
Two clamping nuts  
Width: 24  
*1. The stainless steel wire actuator can move in any direction. However,  
limit the overtravel to within 20 mm from the free position. The force  
that pushes the actuator must not exceed 1.96 N.  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.3 mm2.  
(
)
Thickness: 4  
*3 Use after removing the caution label.  
Plunger  
D5C-1AP0  
(101)  
76  
71  
(3,000)  
24  
*3  
52  
Caution label  
4
4
Overtravel  
16.7 dia.  
4 dia. 7.1 dia.  
29 dia.  
16.5 dia. 5 dia.  
*1  
M18 × 1  
LED Operation indicator  
* 2  
Two internal lock washers  
Two clamping nuts  
Width: 24  
*1. The overtravel of the stainless steel plunger is within 3.5 mm.  
Do not apply a force greater than 9.8 N to the plunger.  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.3 mm2.  
(
)
Thickness: 4  
*3 Use after removing the caution label.  
Free-attachment  
D5C-1AA0  
(104)  
76  
(3,000)  
28  
71  
Lock nut  
*3  
14  
52  
4
Caution label  
4
M4 × 0.7 *1  
16.7 dia.  
4 dia. 7.1 dia.  
29 dia.  
16.5 dia.  
Self-locking nut  
* 2  
M18 × 1  
LED Operation indicator  
Two flat washers  
Two clamping nuts  
Width: 24  
Two internal  
lock washers  
*1. Limit the total length of actuator wire to 1 m or less.  
When mounting the Switch to a metal plate, do not exceed an area of 200 cm2.  
*2 Vinyl insulated round cable (oil- and shock-resistant type)  
4 dia., three conductors × 0.3 mm2.  
(
)
Thickness: 4  
*3 Use after removing the caution label.  
5
D5C  
Safety Precautions  
Refer to Safety Precautions for All Limit Switches.  
CAUTIONS  
Antenna  
<Shape and Extension>  
Make sure that the antenna does not come into contact  
with the human body, otherwise an electric shock may  
be received.  
If a metal plate is used as an antenna by connecting it to the built-in  
or separated antenna of the D5C, the surface area of the metal plate  
must be 200 cm2 maximum (Fig. 1). The antenna can be extended,  
provided that the total length of the antenna is 1 m maximum (Fig. 2)  
and that the bottom of the antenna is at least 10 cm (Fig. 3) away from  
the ground. Refer to the illustrations below  
Precautions for Correct Use  
The D5C may be damaged if the antenna is excessively large or  
heavy or if the antenna is used in locations with excessive vibration or  
shock. Be sure to check the locations before use.  
Mounting  
Do not tighten the nuts with excessive force.  
The maximum permissible tightening force of  
each nut with a washer is 29.4 N·m.  
Mounting Hole Dimension  
Fig. 1  
Fig. 2  
Fig. 3  
Metal plate  
6
1 m max.  
D5C  
2
1
5
200cm max.  
2
4
10 cm min.  
Ground  
3
+0.5  
-0  
18.5  
dia.  
Grounding of Antenna and Sensing  
Object  
1+ ---  
6 1 m  
D5C  
D5C  
<Size of Sensing Object>  
Grounded Object  
If the sensing object is the following grounded conductor, its size  
will not affect the operation of the D5C. Check for the presence of  
insulators sticking to the sensing object or the corrosion of the  
sensing object, however, so that the ground resistance will not  
exceed 3 kΩ.  
<Parallel Arrangement>  
If there are multiple D5Cs are located in parallel, make sure that the  
distance between adjacent antennas is at least 3 cm.  
3 cm min.  
Contact with Grounded Conductor  
The sensing object is equivalently grounded through  
ground resistor R.  
D5C  
3 cm min.  
D5C  
D5C  
D5C  
Grounded  
conductor  
3 kmax.  
D5C  
Maintenance  
R
Make sure that the portion of the antenna that comes into contact  
with sensing objects is free of oil, dirt, or rust, or any other insulator.  
Otherwise, the D5C will not operate.  
R: 3 kmax.  
The degree of protection of the D5C is IP67. The D5C cannot be,  
however, used in the water or oil.  
The sensing object must not come into contact with the human body  
Locations with Sprayed Water or Oil  
Non-grounded Object  
The D5C may malfunction in locations where the D5C is frequently  
exposed to sprayed water or oil. Especially, the D5C may  
malfunction more frequently if it is exposed to sprayed water-  
soluble cutting oil. In such locations, be sure to take appropriate  
measures to protect the D5C from oil and water.  
If the sensing object is the following non-grounded conductor, the  
D5C will operate if the capacitance between the sensing object and  
the ground is 30 pF or more. The larger the surface area of the  
sensing object is, the higher its capacitance will be. The shorter the  
distance between the sensing object and the ground is, the higher  
the capacitance will be. Furthermore, the capacitance greatly  
varies with the ground condition (e.g., dry sand, concrete, or wet  
soil).  
Wiring and Connections  
Be sure to wire the D5C correctly according to the color of each  
cord. Incorrect wiring may damage the internal components of the  
D5C or the D5C may malfunction.  
A maximum of two models can be connected in series provided that  
100 to 240 V is supplied. DC models cannot be connected in series.  
Contact with Non-grounded Conductor  
The sensing object is equivalently grounded through capacitor C.  
Generally, the conductor will  
be detectable if the ambient  
humidity is 60% to 70%RH and  
the surface area of the conductor  
is approximately 300 × 500 mm.  
Non-grounded  
conductor  
D5C  
Load  
30 pF min.  
100 to 240 VAC  
C
D5C  
Be sure to supply power to the D5C via the load. If power is supplied  
to the D5C directly, the fuse will blow.  
C: 30 pF min.  
<Conditions of Sensing Object>  
Power  
source  
The detection of conductors (e.g., iron, stainless steel, aluminum,  
and brass objects) poses no particular problem. A conductor  
coated with paint cannot be detected, however, because there is no  
electrical continuity between the antenna and the conductor.  
Non-conductive objects (e.g., plastic, ceramic, glass, and cloth  
objects) can be detected by grounding them indirectly.  
(Refer to Application Examples on page 1.)  
If there are wire power lines or high-tension lines close to the cable  
of the D5C, be sure to wire the cable of the D5C away from power  
lines or high-tension lines or lay the cable in an exclusive, shielded  
conduit.  
Remove the caution label on the end of the cable before wiring the  
cable.  
6
D5C  
D5C-1A@0 (AC Models)  
Others  
Be aware that the D5C-1A@0 not in operation has a leakage  
current of approximately 2 mA. Especially, if the load is a relay with  
a current flow of 10 mA or less, a reset failure may result due to the  
residual voltage. Therefore, connect a bleeder resistor as shown  
below so that the residual voltage will be less than the reset voltage  
of the load.  
Do not disassemble the D5C, otherwise the internal wiring will be  
damaged and the D5C will fail to operate.  
The sealing of the D5C uses nitrile butadiene rubber (NBR), which  
is highly oil resistive. If exposed to some types of oil or chemical  
indoors or outdoors, however, the NBR may deteriorate. Contact  
your OMRON representative for details.  
When mounting the antenna to the D5C, be sure to tighten the  
antenna to a torque of 0.39 to 0.83 N·m. If the antenna is not  
tightened securely, the built-in contact may break.  
Load  
AC power  
supply Vs  
Bleeder resistor R  
If an appropriate antenna is mounted to a free attachment model,  
hold the nut on the outer side with a wrench so that the nut will not  
move. Then tighten the nut on the inner side within a torque range  
of 0.78 and 1.18 N·m.  
The bleeder resistance and permissible power are obtained from  
the following formula.  
Vs  
Vs2  
R
R≤  
(KΩ) P>  
(mW)  
10I  
Wrench  
P: W number of bleeder load (Practically, the wattage must be a few  
times larger than the obtainable value.)  
I: Load current (mA)  
If a DC relay or DC counter is used as a load connected through an  
electronic timer or current rectification circuit, pay the utmost  
attention so that the leakage current of the D5C AC model will not  
cause the load to malfunction.  
Direction  
of turn  
Antenna  
Sensitivity Adjustment  
The sensitivity of the D5C can be adjusted by turning the adjuster  
on the rear side with a flat-blade screwdriver.  
The sensitivity increases by turning the adjuster clockwise (max. 30 pF)  
and decreases by turning the adjuster counterclockwise (min. 100 pF).  
SENSI  
Set point  
Be sure to turn the adjuster with a torque of 0.08 N·m or less. If  
excessive torque is applied, the adjuster will break.  
Grounding  
<For DC and AC Models>  
In order to maintain the operational reliability of the D5C, be sure to  
ground the blue or black wire of the power cable.  
(Refer to “Output Circuit Diagram” on page 4.)  
Operation may fail if the D5C is not grounded.  
<DC Models>  
The service power supply of the PC (Programmable Controller) is  
not available to the D5C-1D@0. The negative line of the service  
power supply of the PC is not grounded. Therefore, the D5C may  
not operate.  
Furthermore, if the negative line of the service power supply is  
grounded, the noise resistance of the PC will drop.  
<AC Models>  
Provided that single-phase 200 V is supplied to the D5C-1A@0, if  
one phase is grounded, the power supply will be short-circuited and  
a machinery breakdown will result. Use an isolating transformer  
and ground the secondary side of the transformer instead.  
In the above case, be sure to ground the secondary side, otherwise  
the D5C may not operate.  
Brown  
Load  
(White)  
AC  
Blue  
(Black)  
D5C  
The lead wire colors of the D5C have been changed in compliance with the  
latest applicable JIS standards. Colors in parentheses are previous ones.  
7
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2013.1  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2013 All Right Reserved.  

相关型号:

D5C-1DS0

Snap Acting/Limit Switch
OMRON

D5C031

300 gate CMOS pld
INTEL

D5C031-40

300 gate CMOS pld
INTEL

D5C031-50

300 gate CMOS pld
INTEL

D5C032-25

UV-Erasable/OTP PLD
ETC

D5C032-30

8-MACROCELL CMOS PLD
INTEL

D5C032-35

8-MACROCELL CMOS PLD
INTEL

D5C032-40

8-MACROCELL CMOS PLD
INTEL

D5C060-35

EE PLD, PAL-Type, CMOS, CDIP24,
INTEL

D5C060-45

16 MACROCELL CMOS PLD
INTEL