D4N-1A32R [OMRON]

Snap Acting/Limit Switch;
D4N-1A32R
型号: D4N-1A32R
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch

开关
文件: 总15页 (文件大小:3440K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DPull4-resNet S-a@fetyRLimit Switch  
A Series of Pull-reset Models Now  
Available  
CSM_D4N-_R_DS_E_4_1  
Note: Contact your sales representative for details on models  
with safety standard certification.  
• Lineup includes three contact models with 2NC/1NO and 3NC  
contact forms in addition to the previous contact forms 1NC/  
1NO and 2NC.  
• M12-connector models are available, saving on labor and  
simplifying replacement.  
• Standardized gold-clad contacts provide high contact reliability.  
Can be used with both standard loads and microloads.  
• Conforms to EN115, EN81-1 and EN81-2.  
• Certified standards: UL, EN (TÜV), and CCC  
Be sure to read the “Safety Precautions” on page 12.  
Model Number Structure  
Model Number Legend  
D4N-@@@@R  
1 2  
3
1. Conduit size  
1: Pg13.5 (1-conduit)  
2: G1/2 (1-conduit)  
4: M20 (1-conduit)  
6: G1/2 (2-conduit)  
3. Actuator  
20: Roller lever (resin lever, resin roller)  
2G:Adjustable roller lever, form lock (metal lever, resin roller)  
2H:Adjustable roller lever, form lock (metal lever, rubber roller)  
31: Top plunger  
8: M20 (2-conduit)  
32: Top roller plunger  
9: M12 connector (1-conduit)  
2. Built-in Switch  
62: One-way roller arm lever (horizontal)  
72: One-way roller arm lever (vertical)  
A: 1NC/1NO (slow-action)  
B: 2NC (slow-action)  
C: 2NC/1NO (slow-action)  
D: 3NC (slow-action)  
1
D4N-@R  
Ordering Information  
List of Models  
Safety Limit Switches (with Direct Opening Mechanism)  
Consult with your OMRON representative when ordering any models that are not listed in this table.  
Built-in switch mechanism  
1NC/1NO  
(Slow-action)  
2NC  
(Slow-action)  
2NC/1NO  
(Slow-action)  
3NC  
(Slow-action)  
Actuator  
Conduit size  
Direct  
opening  
Direct  
opening  
Direct  
opening  
Direct  
opening  
Model  
Model  
Model  
Model  
Pg13.5  
G1/2  
D4N-1A20R  
D4N-2A20R  
D4N-4A20R  
D4N-9A20R  
D4N-6A20R  
D4N-8A20R  
D4N-1A2GR  
D4N-2A2GR  
D4N-4A2GR  
D4N-9A2GR  
D4N-6A2GR  
D4N-8A2GR  
D4N-1A2HR  
D4N-2A2HR  
D4N-4A2HR  
D4N-9A2HR  
D4N-6A2HR  
D4N-8A2HR  
D4N-1A31R  
D4N-2A31R  
D4N-4A31R  
D4N-9A31R  
D4N-6A31R  
D4N-8A31R  
D4N-1A32R  
D4N-2A32R  
D4N-4A32R  
D4N-9A32R  
D4N-6A32R  
D4N-8A32R  
D4N-1A62R  
D4N-2A62R  
D4N-4A62R  
D4N-9A62R  
D4N-6A62R  
D4N-8A62R  
D4N-1A72R  
D4N-2A72R  
D4N-4A72R  
D4N-9A72R  
D4N-6A72R  
D4N-8A72R  
D4N-1B20R  
D4N-2B20R  
D4N-4B20R  
D4N-9B20R  
D4N-6B20R  
D4N-8B20R  
D4N-1B2GR  
D4N-2B2GR  
D4N-4B2GR  
D4N-9B2GR  
D4N-6B2GR  
D4N-8B2GR  
D4N-1B2HR  
D4N-2B2HR  
D4N-4B2HR  
D4N-9B2HR  
D4N-6B2HR  
D4N-8B2HR  
D4N-1B31R  
D4N-2B31R  
D4N-4B31R  
D4N-9B31R  
D4N-6B31R  
D4N-8B31R  
D4N-1B32R  
D4N-2B32R  
D4N-4B32R  
D4N-9B32R  
D4N-6B32R  
D4N-8B32R  
D4N-1B62R  
D4N-2B62R  
D4N-4B62R  
D4N-9B62R  
D4N-6B62R  
D4N-8B62R  
D4N-1B72R  
D4N-2B72R  
D4N-4B72R  
D4N-9B72R  
D4N-6B72R  
D4N-8B72R  
D4N-1C20R  
D4N-2C20R  
D4N-4C20R  
---  
D4N-1D20R  
D4N-2D20R  
D4N-4D20R  
---  
Roller lever  
(resin lever, resin roller)  
1-conduit  
M20  
M12 connector  
G1/2  
D4N-6C20R  
D4N-8C20R  
D4N-1C2GR  
D4N-2C2GR  
D4N-4C2GR  
---  
D4N-6D20R  
D4N-8D20R  
D4N-1D2GR  
D4N-2D2GR  
D4N-4D2GR  
---  
2-conduit  
1-conduit  
2-conduit  
1-conduit  
2-conduit  
1-conduit  
2-conduit  
1-conduit  
2-conduit  
1-conduit  
2-conduit  
1-conduit  
2-conduit  
M20  
Pg13.5  
G1/2  
Adjustable roller lever,  
form lock  
(metal lever, resin roller)  
M20  
M12 connector  
G1/2  
D4N-6C2GR  
D4N-8C2GR  
D4N-1C2HR  
D4N-2C2HR  
D4N-4C2HR  
---  
D4N-6D2GR  
D4N-8D2GR  
D4N-1D2HR  
D4N-2D2HR  
D4N-4D2HR  
---  
M20  
Pg13.5  
G1/2  
Adjustable roller lever,  
form lock  
(metal lever, rubber roller)  
M20  
M12 connector  
G1/2  
D4N-6C2HR  
D4N-8C2HR  
D4N-1C31R  
D4N-2C31R  
D4N-4C31R  
---  
D4N-6D2HR  
D4N-8D2HR  
D4N-1D31R  
D4N-2D31R  
D4N-4D31R  
---  
M20  
Pg13.5  
G1/2  
Plunger  
M20  
M12 connector  
G1/2  
D4N-6C31R  
D4N-8C31R  
D4N-1C32R  
D4N-2C32R  
D4N-4C32R  
---  
D4N-6D31R  
D4N-8D31R  
D4N-1D32R  
D4N-2D32R  
D4N-4D32R  
---  
M20  
Pg13.5  
G1/2  
Roller plunger  
M20  
M12 connector  
G1/2  
D4N-6C32R  
D4N-8C32R  
D4N-1C62R  
D4N-2C62R  
D4N-4C62R  
---  
D4N-6D32R  
D4N-8D32R  
D4N-1D62R  
D4N-2D62R  
D4N-4D62R  
---  
M20  
Pg13.5  
G1/2  
One-way roller arm lever  
(horizontal)  
M20  
M12 connector  
G1/2  
D4N-6C62R  
D4N-8C62R  
D4N-1C72R  
D4N-2C72R  
D4N-4C72R  
---  
D4N-6D62R  
D4N-8D62R  
D4N-1D72R  
D4N-2D72R  
D4N-4D72R  
---  
M20  
Pg13.5  
G1/2  
One-way roller arm lever  
(vertical)  
M20  
M12 connector  
G1/2  
D4N-6C72R  
D4N-8C72R  
D4N-6D72R  
D4N-8D72R  
M20  
2
D4N-@R  
Specifications  
Standards and EC Directives  
Conforms to the following EC Directives:  
Certified Standard Ratings  
TÜV (EN60947-5-1), CCC (GB14048.5)  
Machinery Directive  
Low Voltage Directive  
EN50047  
EN60204-1  
EN1088  
Utilization  
AC-15  
DC-13  
Item  
category  
Rated operating current (Ie) 3 A  
Rated operating voltage (Ue) 240 V  
0.27 A  
250 V  
GS-ET-15  
Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a  
short-circuit protection device. This fuse is not built into the  
Switch.  
Certified Standards  
Certification body  
Standard  
EN60947-5-1  
(certified direct opening)  
UL508, CSA C22.2 No.14 E76675  
GB14048.5 2004010305105973  
File No.  
UL/CSA (UL508, CSA C22.2 No. 14)  
A300  
TÜV SÜD  
*1  
Current (A)  
Make Break  
Volt-amperes (VA)  
Make Break  
Rated  
voltage  
UL *2  
CQC (CCC) *3  
Carry current  
120 VAC  
240 VAC  
60  
30  
6
3
*1. Consult your OMRON representative for details.  
*2. Certification for CSA C22.2 No. 14 is authorized by the UL mark.  
*3. Ask your OMRON representative for information on certified  
models.  
10 A  
7,200  
720  
Q300  
Current (A)  
Volt-amperes (VA)  
Make Break  
Rated  
Carry current  
voltage  
Make  
Break  
0.55  
0.27  
125 VDC  
250 VDC  
0.55  
0.27  
2.5 A  
69  
69  
3
D4N-@R  
Characteristics  
Degree of protection *1  
IP67 (EN60947-5-1)  
Mechanical  
1,000,000 operations min.  
Durability *2  
500,000 operations min. (3 A resistive load at 250 VAC) *3  
300,000 operations min. (10 A resistive load at 250 VAC)  
Electrical  
Operating speed  
1 to 500 mm/s (D4N-1A20R)  
30 operations/minute max.  
25 mΩ max.  
Operating frequency  
Contact resistance  
Minimum applicable load *4  
Rated insulation voltage (Ui)  
Rated frequency  
1 mA resistive load at 5 VDC (N-level reference value)  
300 V  
50/60 Hz  
Protection against electric shock  
Pollution degree (operating environment)  
Class II (double insulation)  
3 (EN60947-5-1)  
Between terminals of  
same polarity  
2.5 kV  
4 kV  
Impulse withstand  
voltage  
Between terminals of  
different polarity  
(EN60947-5-1)  
Between each terminal  
and non-current carrying 6 kV  
metallic parts  
Insulation resistance  
Contact gap  
100 MΩ min.  
2 × 2 mm min.  
Vibration resistance Malfunction  
10 to 55 Hz, 0.75 mm single amplitude  
1,000 m/s2  
300 m/s2  
Destruction  
Shock resistance  
Malfunction  
Conditional short-circuit current  
Conventional free air thermal current (Ith)  
Ambient operating temperature  
Ambient operating humidity  
Weight  
100 A (EN60947-5-1)  
10 A (EN60947-5-1)  
30 to 70°C (with no icing)  
95% max.  
Approx. 92 g (D4N-1A20R)  
Note: 1. The above values are initial values.  
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity.  
Doing so may result in roughening of the contact surface and contact reliability may be lost.  
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for  
the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the  
D4N-@R in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated  
wear, Switch damage or malfunctioning may occur.  
*2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your  
OMRON representative.  
*3. Do not pass the 3 A, 250 VAC load through more than 2 circuits.  
*4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual  
load beforehand.  
4
D4N-@R  
Structure and Nomenclature  
Structure  
Safety-oriented Lever Setting (Form lock mechanism)  
Head  
Grooves which engage the lever are cut in the lever and  
rotary shaft to prevent the lever from slipping against the  
rotary shaft. The actuator locks (self-holding) when it moves  
to the lock position.  
The direction of the Switch Head can be  
adjusted to any of the four directions, except for  
Switches with Roller Plungers, which can be  
adjusted to either of two directions differing by  
90°C.  
Reset Head (Blue)  
The direction of the reset head can be adjusted to any of  
the four directions.  
Conduit  
A wide variety of conduits is available.  
Built-in Switch  
Size  
Box  
1-conduit model 2-conduit model  
The built-in switch has a direct opening mechanism that  
forcibly separates the NC contact even when there is  
contact deposit.  
Pg13.5  
G1/2  
M20  
Yes  
Yes  
Yes  
Yes  
---  
Yes  
Yes  
---  
Cover  
The cover, with a hinge on its lower part, can be opened  
by removing the screw of the cover, which ensures ease  
of maintenance and wiring.  
M12 connector  
Note: M12 connector types are not available for  
Switches with three contacts.  
Contact Form  
Model  
Contact  
Contact form  
Operating pattern  
Remarks  
Only NC contacts 11-12 have a  
Zb  
certified direct opening  
11-12  
33-34  
ON  
11  
33  
12  
34  
mechanism.  
D4N-@A@R  
1NC/1NO  
Stroke  
The terminals 11-12 and 33-34  
can be used as unlike poles.  
Only NC contacts 11-12 and  
31-32 have a certified direct  
Zb  
Zb  
11-12  
31-32  
ON  
11  
31  
12  
32  
opening mechanism.  
D4N-@B@R  
D4N-@C@R  
2NC  
Stroke  
Stroke  
The terminals 11-12 and 31-32  
can be used as unlike poles.  
Only NC contacts 11-12 and  
21-22 have a certified direct  
opening mechanism.  
11-12  
21-22  
33-34  
11  
21  
33  
12  
22  
34  
ON  
2NC/1NO  
The terminals 11-12, 21-22, and  
33-34 can be used as unlike  
poles.  
Only NC contacts 11-12, 21-22,  
and 31-32 have a certified direct  
Zb  
11-12  
21-22  
31-32  
11  
21  
31  
12  
22  
32  
opening mechanism.  
ON  
D4N-@D@R  
3NC  
The terminals 11-12, 21-22, and  
31-32 can be used as unlike  
poles.  
Stroke  
5
D4N-@R  
Direct Opening Mechanism  
1NC/1NO Contact (Slow-action)  
Fixed contact (NC)  
Contact spring  
Return spring  
Movable contacts  
Fixed contact (NO)  
Conforms to EN60947-5-1 Direct Opening  
(Only NC Contact has a direct opening  
mechanism.)  
When contact welding occurs, the contacts are  
separated from each other by the plunger being  
pushed in.  
Plunger  
2NC Contact (Slow-action)  
Fixed contact (NC)  
Movable contact  
Plunger  
Contact spring  
Return spring  
Conforms to EN60947-5-1 Direct Opening  
(Both NC Contacts have a direct opening  
mechanism.)  
When contact welding occurs, the contacts are  
separated from each other by the plunger being  
pushed in.  
6
D4N-@R  
Dimensions and Operating Characteristics  
(Unit: mm)  
Switches  
1-conduit Models  
Adjustable Roller Lever, Form Lock  
Roller Lever (Resin Lever, Resin Roller)  
(with Metal Lever, Resin Roller)  
D4N-1@20R  
D4N-2@20R  
D4N-1@2GR  
D4N-4@2GR  
D4N-2@2GR  
D4N-9@2GR *  
D4N-4@20R  
D4N-9@20R *  
1
47  
40  
(27)  
1
17.5 dia. × 6.8  
resin roller  
26R  
1
45  
0.2  
11  
1
39.5  
Resin lever  
17.5 dia. × 6.8  
resin roller  
Blue  
Blue  
(31)  
11  
20.5 × 20.5  
14 dia.  
0.2  
20 to 66R  
43.5  
20.5 × 20.5  
34  
16.7  
0.2  
14 dia.  
9
25  
21.5  
43.5  
2.5  
34  
0.1  
0.1  
20  
22  
16.7  
0.2  
47  
0.2  
9
55  
2.15 0.05R  
mounting  
holes  
21.5  
2.5  
0.1  
0.1  
20  
22  
2.15 0.05R  
mounting holes  
0.2  
47  
55  
0.2  
14.2  
30  
22  
Conduit cap  
31 max.  
36  
Two, 4+00.15 dia. holes  
Depth: 5  
0.2  
Conduit cap  
14.2  
30  
22  
Two, 4+00.15 dia.  
holes  
31 max.  
Depth: 5  
1-conduit M12 Connectors  
D4N-9@@@R  
Adjustable Roller Lever, Form Lock  
(with Metal Lever, Rubber Roller)  
D4N-1@2HR  
D4N-2@2HR  
D4N-4@2HR  
D4N-9@2HR *  
1
48.2  
1
41.3  
50 dia. × 8  
rubber roller  
Resin bearing  
Blue  
(29.2)  
(14)  
M12 × 1  
0.2  
11  
14.2  
30  
32 to 66R  
(P:2)  
20.5 × 20.5  
14 dia.  
25  
43.5  
34  
16.7  
0.2  
9
21.5  
2.5  
0.1  
0.1  
20  
22  
2.15 0.05R  
mounting holes  
0.2  
47  
55  
Stainless steel  
lever  
0.2  
14.2  
30  
Two, 4+0.15 dia. holes  
22  
Conduit cap  
31 max.  
0
Depth: 5  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
* Refer to the right above diagram for details on 1-conduit M12 connectors.  
Note: Variation occurs in the simultaneity of contact opening/closing  
operations of 2NC, 2NC/1NO, and 3NC contacts. Check  
contact operation.  
Model D4N-@@20R D4N-@@2GR D4N-@@2HR  
*1  
Operating characteristics  
Locking force  
Locking travel  
Pretravel  
LF max.  
6.4 N  
55°  
5.6 N  
55°  
5.4 N  
55°  
*1. The operating characteristics of these Switches were measured  
with the roller lever set at 32 mm.  
*2. These PT values are possible when the NC contacts are open  
(OFF).  
*3. These PT values are reference values possible when the NO  
contacts are closed (ON). (1NC/1NO models only)  
*4. Reference value.  
LT max.  
PT 1 *2  
(PT 2) *3  
(TT) *4  
18 to 27°  
(44°)  
80°  
18 to 27°  
(44°)  
80°  
18 to 27°  
(44°)  
80°  
Pretravel  
Total travel  
Direct opening force DOF min. *5  
Direct opening travel DOT min. *5  
20 N  
50°  
20 N  
50°  
20 N  
50°  
*5. For safe use, always make sure that the minimum values or  
greater are provided.  
7
D4N-@R  
1-conduit Models  
Roller Plunger  
D4N-1@32R  
D4N-4@32R  
Plunger  
D4N-2@32R  
D4N-9@32R *  
D4N-1@31R  
D4N-2@31R  
D4N-9@31R *  
D4N-4@31R  
Blue  
Blue  
21.5  
20.5 × 20.5  
20.5 × 20.5  
9.5 dia. × 5  
21.5  
0.2  
11  
0.2  
6 dia.  
resin roller  
11  
14 dia.  
14 dia.  
OP  
OP  
41  
2.5  
(27)  
2.5  
16.7  
55  
0.2  
9
16.7  
55  
0.2  
9
0.1  
0.1  
20  
22  
0.1  
0.1  
20  
22  
2.15 0.05R  
mounting holes  
0.2  
47  
0.2  
47  
2.15 0.05R  
mounting holes  
Two, 4+0.15 dia.  
holes  
Depth: 5  
0.2  
14.2  
30  
Conduit cap  
22  
Two, 4+0.15 dia.  
holes  
Depth: 5  
0.2  
0
14.2  
30  
22  
Conduit cap  
0
31 max.  
31 max.  
36  
36  
One-way Roller Arm Lever  
(Horizontal)  
One-way Roller Arm Lever  
(Vertical)  
D4N-1@62R  
D4N-2@62R  
D4N-1@72R  
D4N-2@72R  
D4N-4@62R  
D4N-9@62R *  
D4N-4@72R  
D4N-9@72R *  
Operating  
direction  
OP  
12  
21.5  
Blue  
14.8  
Blue  
21.5  
0.2  
11  
0.2  
12 dia. × 5  
11  
0.2  
0.2  
11  
11  
12 dia. × 5  
resin roller  
resin roller  
19R  
14.7  
13.5  
20R  
14 dia.  
10.2  
10.2  
14 dia.  
OP  
39.3  
0.2  
35.5  
2.5  
0.2  
35.5  
16.7  
0.2  
9
16.7  
0.2  
9
2.5  
0.1  
0.1  
20  
22  
0.1  
20  
22  
0.2  
47  
2.15 0.05R  
2.15 0.05R  
mounting holes  
55  
0.1  
0.2  
47  
55  
mounting holes  
Operating  
direction  
0.2  
14.2  
22  
14.2  
30  
Two, 4+0.15 dia.  
holes  
Conduit cap  
Two, 4+0.15 dia.  
holes  
0.2  
22  
Conduit cap  
30  
36  
0
0
31 max.  
31 max.  
36  
Depth: 5  
Depth: 5  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
* Refer to page 7 for details on 1-conduit M12 connectors.  
Model  
D4N-@@31R D4N-@@32R D4N-@@62R D4N-@@72R  
Operating characteristics  
Locking force  
Locking travel  
Pretravel  
LF max.  
LT max.  
10.8 N  
10.8N  
7.5 N  
7.9 N  
Note: Variation occurs in the simultaneity of  
contact opening/closing operations of  
2NC, 2NC/1NO, and 3NC contacts. Check  
contact operation.  
4.5 mm  
4.5 mm  
2 mm  
7 mm  
7 mm  
PT 1 max. *1 2 mm  
(PT 2) *2 (2.9 mm)  
4 mm  
4 mm  
Pretravel  
(2.9 mm)  
(5.2 mm)  
(4.3 mm)  
*1. These PT values are possible when the NC  
contacts are open (OFF).  
*2. These PT values are reference values  
possible when the NO contacts are closed  
(ON). (1NC/1NO models only)  
Operating position OP  
Total travel (TT) *3  
Direct opening force DOF min. *4 20 N  
Direct opening travel DOT min. *4 3.2 mm  
34 0.5 mm 44.4 0.8 mm 53 0.8 mm 27 0.8 mm  
(6 mm)  
(6 mm)  
20 N  
(9 mm)  
20 N  
(9 mm)  
20 N  
3.2 mm  
5.8 mm  
4.8 mm  
*3. Reference value.  
*4. For safe use, always make sure that the  
minimum values or greater are provided.  
8
D4N-@R  
2-conduit Models  
Adjustable Roller Lever, Form Lock  
(with Metal Lever, Resin Roller)  
D4N-6@2GR  
Roller Lever (Resin Lever, Resin Roller)  
D4N-6@20R  
D4N-8@20R  
1
47  
40  
(27)  
D4N-8@2GR  
1
1
17.5 dia. × 6.8  
45  
resin roller  
Blue  
1
39.5  
Blue  
17.5 dia. × 6.8  
resin roller  
0.2  
11  
26R  
(31)  
11  
Resin lever  
0.2  
20.5 × 20.5  
14 dia.  
20 to 66R  
20.5 × 20.5  
2.5  
43.5  
34  
14 dia.  
43.5  
5.4  
25  
0.216.7  
21.5  
9
34  
5.4  
2.5  
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
16.7  
20.5  
20.5  
Cap  
21.5  
0.2  
0.2  
9
39  
25 dia.  
2.15 0.05R  
mounting  
holes  
47  
0.2  
2.15 0.05R  
mounting holes  
39  
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
25 dia.  
47  
Cap  
Conduit cap  
Conduit cap  
0.2  
42  
(3)  
14.2  
30  
56 max.  
0.2  
42  
(3)  
36  
14.2  
30  
56 max.  
Two, 4+0.15 dia. holes  
Two, 4+00.15 dia. holes  
0
Depth: 5  
Depth: 5  
Adjustable Roller Lever, Form Lock  
(with Metal Lever, Rubber Roller)  
D4N-6@2HR  
D4N-8@2HR  
1
48.2  
Resin bearing  
Blue  
1
41.3  
(29.2)  
50 dia. × 8  
rubber roller  
0.2  
11  
32 to 66R  
(P:2)  
20.5 × 20.5  
Stainless  
steel lever  
14 dia.  
25  
43.5  
34  
5.4  
2.5  
16.7  
20.5  
21.5  
0.2  
9
2.15 0.05R  
mounting holes  
0.1  
0.1  
0.1  
0.1  
0.2  
20  
22  
40  
42  
39  
25 dia.  
47  
Cap  
Conduit cap  
0.2  
42  
(3)  
14.2  
30  
56 max.  
Two, 4+00.15 dia. holes  
Depth: 5  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
Model  
D4N-@@20R  
D4N-@@2GR  
D4N-@@2HR  
Operating characteristics  
Locking force  
Locking travel  
Pretravel  
LF max.  
6.4 N  
55°  
5.6 N  
55°  
5.4 N  
55°  
Note: Variation occurs in the simultaneity of contact  
opening/closing operations of 2NC, 2NC/1NO,  
and 3NC contacts. Check contact operation.  
LT max.  
PT 1 *1  
(PT 2) *2  
(TT) *3  
18° to 27°  
(44°)  
18° to 27°  
(44°)  
80°  
18° to 27°  
(44°)  
80°  
*1. These PT values are possible when the NC  
contacts are open (OFF).  
*2. These PT values are reference values possible  
when the NO contacts are closed (ON). (1NC/  
1NO models only)  
Pretravel  
Total travel  
80°  
Direct opening force DOF min. *4 20 N  
Direct opening travel DOT min. *4 50°  
20 N  
50°  
20 N  
50°  
*3. Reference value.  
*4. For safe use, always make sure that the minimum  
values or greater are provided.  
9
D4N-@R  
2-conduit Models  
Roller Plunger  
D4N-6@32R  
D4N-8@32R  
Plunger  
D4N-6@31R  
D4N-8@31R  
21.5  
9.5 dia. × 5  
20.5 × 20.5  
14 dia.  
20.5 × 20.5  
6 dia.  
resin roller  
0.2  
11  
21.5  
0.2  
11  
14 dia.  
OP  
41  
2.5  
2.5  
5.4  
OP  
5.4  
(27)  
0.216.7  
0.216.7  
9
9
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
20.5  
Cap  
20.5  
Cap  
0.2  
2.15 0.05R  
mounting holes  
2.15 0.05R  
mounting holes  
39  
25 dia.  
0.2  
39  
25 dia.  
47  
47  
Conduit cap  
Blue  
Conduit cap  
0.2  
42  
(3)  
0.2  
42  
(3)  
14.2  
30  
14.2  
30  
56 max.  
Blue  
56 max.  
36  
36  
Two, 4+0.15 dia. holes  
Depth: 5  
Two, 4+0.15 dia. holes  
Depth: 5  
0
0
One-way Roller Arm Lever  
(Vertical)  
One-way Roller Arm Lever  
(Horizontal)  
D4N-6@72R  
D4N-6@62R  
D4N-8@72R  
D4N-8@62R  
OP  
12  
Operating direction  
21.5  
14.8  
12 dia. × 5  
21.5  
0.2  
11  
0.2  
11  
resin roller  
0.2  
0.2  
11  
11  
12 dia. x 5  
resin roller  
19R  
14.7  
13.5  
20R  
14 dia.  
10.2  
10.2  
14 dia.  
5.4  
OP  
0.2  
0.2  
35.5  
35.5  
2.5  
5.4  
39.3  
2.5  
16.7  
0.2  
9
0.2  
9
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
2.15 0.05R  
mounting holes  
20.5  
0.1  
0.1  
0.1  
0.1  
0.2  
20  
22  
40  
42  
39  
25 dia.  
20.5  
2.15 0.05R  
mounting holes  
0.2  
39  
25 dia.  
47  
47  
Operating  
direction  
Cap  
Conduit cap  
Cap  
Conduit cap  
0.2  
42  
(3)  
0.2  
14.2  
30  
42  
(3)  
56 max.  
14.2  
30  
Blue  
56 max.  
36  
36  
Two, 4+0.15 dia. holes  
Depth: 5  
Blue  
0
Two, 4+0.15 dia. holes  
0
Depth: 5  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
Model  
D4N-@@31R D4N-@@32R D4N-@@62R D4N-@@72R  
Operating characteristics  
Locking force  
Locking travel  
Pretravel  
LF max.  
LT max.  
10.8 N  
10.8N  
7.5 N  
7.9 N  
Note: Variation occurs in the simultaneity of contact opening/  
closing operations of 2NC, 2NC/1NO, and 3NC  
contacts. Check contact operation.  
4.5 mm  
4.5 mm  
2 mm  
7 mm  
7 mm  
PT 1 max. *1 2 mm  
4 mm  
4 mm  
*1. These PT values are possible when the NC contacts are  
open (OFF).  
*2. These PT values are reference values possible when the  
NO contacts are closed (ON). (1NC/1NO models only)  
*3. Reference value.  
Pretravel  
(PT 2) *2  
OP  
(2.9 mm)  
(2.9 mm)  
(5.2 mm)  
(4.3 mm)  
Operating position  
Total travel  
34 0.5 mm 44.4 0.8 mm 53 0.8 mm 27 0.8 mm  
(TT) *3  
(6 mm)  
(6 mm)  
20 N  
(9 mm)  
20 N  
(9 mm)  
20 N  
Direct opening force DOF min. *4 20 N  
Direct opening travel DOT min. *4 3.2 mm  
3.2 mm  
5.8 mm  
4.8 mm  
*4. For safe use, always make sure that the minimum values  
or greater are provided.  
10  
D4N-@R  
Levers Refer to the following diagrams for the angles and positions of the dogs.  
Roller Lever  
(D4N-@@20R)  
Adjustable Roller Lever, Form Lock  
(with Metal Lever, Resin Roller)  
(D4N-@@2GR)  
Adjustable Roller Lever, Form Lock  
(with Metal Lever, Rubber Roller)  
(D4N-@@2HR)  
2
40  
30°  
10 min.  
2
40  
2
42  
10 min.  
10 min.  
Dog  
45 min.  
Dog  
30°  
Dog  
40 min.  
20 min. 30°  
25 min.  
5 min.  
86+1  
56+1  
15 min.  
0
0
30°  
71+1  
0
71+1  
0
51+1  
0
50  
65R 31R  
65R 20R  
Sealed Plunger  
(D4N-@@31R)  
Roller Plunger  
(D4N-@@32R)  
0
12.52.5  
0
12.52.5  
Dog  
Dog  
Dog  
2.5  
Dog  
20 min.  
30°  
31 min.  
41+1  
41 min.  
0
10 min.  
One-way Roller Arm Lever  
(Vertical)  
One-way Roller Arm Lever  
(Horizontal)  
(D4N-@@62R)  
(D4N-@@72R)  
0
0
12.5 2.5  
12.52.5  
Dog  
10 min.  
5 min.  
30°  
5 min.  
20 min. 30°  
Dog  
47+1  
0
30 max.  
10 min.  
22+1 20 min.  
0
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
11  
D4N-@R  
Safety Precautions  
Be sure to read the precautions for all D4N-@R models in the website at: http://www.ia.omron.com/.  
!CAUTION  
Switch Mounting  
Mount the Switch using M4 screws and spring washers and tighten  
the screws to the specified torque.  
Electric shock may occasionally occur.  
Do not use metal connectors or metal conduits.  
For safety, use screws that cannot be easily removed, or use an  
equivalent measure to ensure that the Switch is secure.  
As shown below, two studs with a maximum height of 4.8 mm and  
Precautions for Safe Use  
0.05  
a diameter of 4  
mm can be provided, the studs inserted into the  
0.15  
Do not use the Switch submerged in oil or water, or in locations  
continuously subject to splashes of oil or water. Doing so may  
result in oil or water entering the Switch interior. (The IP67 degree  
of protection specification for the Switch refers to water penetration  
while the Switch is submersed in water for a specified period of  
time.)  
Always attach the cover after completing wiring and before using  
the Switch. Also, do not turn ON the Switch with the cover open.  
Doing so may result in electric shock.  
Do not switch circuits for two or more standard loads (250 VAC,  
3 A). Doing so may adversely affect insulation performance.  
Make sure that the actuator is pushed into the lock position. Not  
doing so may result in the actuator becoming unlocked, causing an  
accident.  
holes on the bottom of the Switch, and the Switch secured at four  
locations to increase the mounting strength.  
Switch Mounting Holes  
One-conduit Type  
Two, M4  
0.1  
2.5  
0.1  
20  
0.1  
22  
0.1  
47  
Mounting hole  
Mounting surface  
Always reset the Switch manually. Not doing so may result in  
damage to the reset function.  
Mounting pin  
insertion hole  
0.1  
22  
0.05  
0.15  
0.05  
4
dia.  
4
dia.  
0.15  
height, 4.8 max.  
height, 4.8 max.  
Precautions for Correct Use  
Two-conduit Type  
The Switch contacts can be used with either standard loads or  
microloads. Once the contacts have been used to switch a load,  
however, they cannot be used to switch smaller loads. The contact  
surfaces will become rough once they have been used and contact  
reliability for smaller loads may be reduced.  
Two, M4  
0.1  
2.5  
0.1  
5.35  
0.1  
0.1  
0.1  
0.1  
20  
22  
40  
42  
0.1  
39  
Mounting Method  
Appropriate Tightening Torque  
Tighten each of the screws to the specified torque. Loose screws may  
result in malfunction of the Switch within a short time.  
0.1  
42  
0.05  
0.15  
4
dia.  
1
2
3
4
5
6
7
Terminal screw  
0.6 to 0.8 N·m  
height, 4.8 max.  
Cover mounting screw 0.5 to 0.7 N·m  
Changing the Head Direction  
Head mounting screw  
Lever mounting screw  
Body mounting screw  
0.5 to 0.6 N·m  
1.6 to 1.8 N·m  
0.5 to 0.7 N·m  
By removing the four screws of the head, the mounting direction of  
the head can be changed. The head can be mounted in four  
directions.  
Be sure that no foreign material will enter the head during a change  
in direction.  
Connector, M12 adaptor 1.8 to 2.2 N·m  
Cap screw 1.3 to 1.7 N·m  
Changing the Lever  
3
The lever mounting screws can be used to set the lever position to  
any position in a 360° angle at 7.5° increments. Grooves are incised  
on the lever and rotary shaft that engage to prevent the lever from  
slipping against the rotary shaft. The screws on adjustable roller lever  
models can also loosened to change the length of the lever.  
Remove the screws from the front of the lever before mounting the  
lever in reverse (front/back), and set the level so that operation will be  
completed before exceeding a range of 180° on the horizontal.  
4
5
1
7
6
2
12  
D4N-@R  
Wiring  
Wiring  
Contact Arrangement  
When connecting to the terminals via insulating tube and M3.5  
crimp terminals, arrange the crimp terminals as shown below so  
that they do not rise up onto the case or the cover.  
Applicable lead wire size: AWG20 to AWG18 (0.5 to 0.75 mm2).  
Use lead wires of an appropriate length, as shown below. Not  
doing so may result in excess length causing the cover to rise and  
not fit properly.  
The contact arrangements are shown below.  
Screw Terminal Type  
D4N-@D@@R (3NC)  
D4N-@C@@R (2NC/1NO)  
11  
21  
31  
12  
22  
32  
11  
21  
33  
12  
22  
34  
One-conduit Type (3 Poles)  
A B  
D4N-@B@@R (2NC)  
D4N-@A@@R (1NC/1NO)  
A
C
E
B
D
F
C
D
11 12  
E
F
11  
31  
12  
32  
11  
33  
12  
34  
21 22  
33 34  
42 mm  
33 mm  
28 mm  
Connector Type  
Tolerance 2 mm  
D4N-9B@@R (2NC)  
Two-conduit Type (3 Poles)  
(1) 11  
(3) 31  
12 (2)  
32 (4)  
1
Left hand  
E C A  
Right hand  
B D F  
2
4
A
C
E
B
D
F
11 12  
D4N-9A@@R (1NC/1NO)  
B D F  
E C A  
3
21 22  
33 34  
(1) 11  
(3) 33  
12 (2)  
34 (4)  
42 mm  
42 mm  
Pin No. (Terminal No.)  
28 mm  
28 mm  
Tolerance 2 mm  
Tolerance 2 mm  
Applicable socket: XS2F-D421 series (OMRON).  
Refer to the Connector Catalog for details on socket pin numbers  
and lead wire colors.  
Do not push crimp terminals into gaps in the case interior. Doing so  
may cause damage or deformation of the case.  
Use crimp terminals not more than 0.5 mm in thickness. Otherwise,  
they will interfere with other components inside the case.  
[Reference] The crimp terminals shown below are not more than  
0.5 mm thick.  
Socket Tightening (Connector Type)  
Turn the socket connector screws by hand and tighten until no  
space remains between the socket and the plug.  
Make sure that the socket connector is tightened securely.  
Otherwise, the rated degree of protection (IP67) may not be  
maintained and vibration may loosen the socket connector.  
Manufacturer  
Type  
FN0.5-3.7 (F Type)  
N0.5-3.7 (Straight Type)  
J.S.T. Mfg. Co.  
Conduit Opening  
Connect a recommended connector to the opening of the conduit  
and tighten the connector to the specified torque. The case may be  
damaged if an excessive tightening torque is applied.  
L
t: 0.5 mm  
dz dia.: 3.7 mm  
D dia.: 2.9 mm  
B: 6.6 mm  
l
F
L: 19 mm  
F: 7.7 mm  
I: 8.0 mm  
Use a cable with a suitable diameter for the connector.  
Attach and tighten a conduit cap to the unused conduit opening  
when wiring. Tighten the conduit cap to the specified torque. The  
conduit cap is provided with the Switch (2-conduit types).  
B
D dia.  
dz dia.  
Terminal screw  
Crimp terminal  
Correct  
Incorrect  
13  
D4N-@R  
Recommended Connectors  
Use connectors with screws not exceeding 9 mm, otherwise the  
screws will protrude into the case interior, interfering with other  
components in the case.  
The connectors listed in the following table have connectors with  
thread sections not exceeding 9 mm.  
Use the recommended connectors to ensure conformance to IP67.  
Applicable cable  
Size  
G1/2  
Manufacturer  
LAPP  
Model  
diameter  
ST-PF1/2  
5380-1002  
6.0 to 12.0 mm  
ST-13.5  
5301-5030  
Pg13.5  
M20  
LAPP  
6.0 to 12.0 mm  
7.0 to 13.0 mm  
ST-M20 × 1.5  
5311-1020  
LAPP  
Use LAPP connectors together with seal packing (JPK-16, GP-13.5,  
or GPM20), and tighten to the specified tightening torque. Seal  
packing is sold separately.  
LAPP is a German manufacturer.  
Others  
When attaching a cover, be sure that the seal rubber is in place and  
that there is no foreign material present. If the cover is attached  
with the seal rubber out of place or if foreign material is stuck to the  
rubber, a proper seal will not be obtained.  
Do not use any screws to connect the cover other than the  
specified ones. The seal characteristics may be reduced.  
With rubber roller lever models, the rubber roller may turn white  
over time, but this will not affect the quality of operation.  
Use the following recommended countermeasures to prevent  
telegraphing when using adjustable or long levers.  
1. Make the rear edge of the dog smooth with an angle of 15° to  
30° or make it in the shape of a quadratic curve.  
2. Design the circuit so that no error signal will be generated.  
14  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2012.4  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2012 All Right Reserved.  

相关型号:

D4N-1A62

Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, 9mm, Screw Terminal, One-way Roller Lever Actuator, Panel Mount
OMRON

D4N-1A62R

Snap Acting/Limit Switch
OMRON

D4N-1A72

Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, 9mm, Screw Terminal, One-way Roller Lever Actuator, Panel Mount
OMRON

D4N-1B20

Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards
OMRON

D4N-1B20R

Snap Acting/Limit Switch
OMRON

D4N-1B22

Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards
OMRON

D4N-1B25

Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards
OMRON

D4N-1B26

Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards
OMRON

D4N-1B2G

Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards
OMRON

D4N-1B2GR

Snap Acting/Limit Switch
OMRON

D4N-1B2H

Snap Acting/Limit Switch, DPST, Momentary, 2.5A, 250VDC, Screw Terminal, Adjustable Roller Lever Actuator, Panel Mount
OMRON

D4N-1B2HR

Snap Acting/Limit Switch
OMRON