D4B-161RN [OMRON]

Snap-action contact with certified direct opening operation certification; 与认证直接打开操作认证速动触点
D4B-161RN
型号: D4B-161RN
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap-action contact with certified direct opening operation certification
与认证直接打开操作认证速动触点

文件: 总16页 (文件大小:2857K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Safety Limit Switch  
D4B-@N  
CSM_D4B-_N_DS_E_5_1  
Snap-action contact with certified direct  
Note: Contact your sales representative for details on models  
with safety standard certification.  
opening operation certification  
.
Maintenance, seal, and resistance to  
shock increased and direct opening  
mechanism added.  
Three-conduit switches and 2NC  
switches are also available.  
• Direct opening mechanism (NC contacts only) added to  
enable opening contacts when faults occur, such as fused  
contacts.  
• Safety of lever settings ensured using a mechanism that  
engages a gear between the operating position indicator plate  
and the lever.  
• Equipped with a mechanism that indicates the applicable  
operating zone, as well as push-button switching to control left  
and right motion.  
• Head seal structure strengthened to improve seal properties  
(TÜV: IEC IP67, UL: NEMA 3, 4, 4X, 6P, and 13).  
• Wide standard operating temperature range:  
–40 to 80°C (standard type).  
• Models with gold-plated contacts added to the series to  
enable handling microloads.  
• Certified standards: UL, CSA, EN (TÜV), and CCC.  
Be sure to read the “Safety Precautions” on page 14  
and the “Precautions for All Safety Limit Switches” .  
Model Number Structure  
Model Number Legend  
D4B-@@@@N  
1
2
3
1. Conduit size  
3. Actuator  
1: PG13.5 (1-conduit)  
00: Switch box (without head)  
11: Roller lever (resin roller)  
15: Roller lever (stainless steel roller)  
1R:Roller lever  
2: G1/2 (PF1/2) (1-conduit)  
3: 1/2-14NPT (1-conduit)  
4: M20 (1 conduit)  
5: PG13.5 (3-conduit)  
6: G1/2 (PF1/2) (3-conduit)  
7: 1/2-14NPT (3-conduit)  
(conventional D4B-compatible)  
16: Adjustable roller lever  
17: Adjustable rod lever  
70: Top plunger  
8: M20 (3-conduit)  
2. Built-in Switch  
1: 1NC/1NO (snap-action)  
71: Top roller plunger  
81: Coil spring  
3: 1NC/1NO (snap-action) gold-plated contacts  
5: 1NC/1NO (slow-action) *  
6: 1NC/1NO (slow-action) gold-plated contacts *  
A: 2NC (slow-action)  
87: Plastic rod  
B: 2NC (slow-action) gold-plated contacts  
* Excluding D4B-@@81N and D4B-@@87N models.  
1
D4B-@N  
Ordering Information  
Set Model Numbers  
Consult with your OMRON representative when ordering any models that are not listed in this table.  
Safety Limit Switches (with Direct Opening Mechanism)  
1NC/1NO (Snap-action)  
1NC/1NO (Slow-action)  
2NC (Slow-action)  
Actuator  
Conduit openings  
Direct  
Model  
Direct  
opening  
Direct  
opening  
Model  
Model  
opening  
Pg13.5  
D4B-1111N  
D4B-1511N  
D4B-2511N  
D4B-3511N  
D4B-4511N  
D4B-5511N  
D4B-6511N  
D4B-7511N  
D4B-8511N  
D4B-1515N  
D4B-2515N  
D4B-3515N  
D4B-4515N  
D4B-5515N  
D4B-1570N  
D4B-2570N  
D4B-3570N  
D4B-4570N  
D4B-5570N  
D4B-6570N  
D4B-7570N  
D4B-8570N  
D4B-1571N  
D4B-2571N  
D4B-3571N  
D4B-4571N  
D4B-5571N  
D4B-6571N  
D4B-7571N  
D4B-8571N  
D4B-1A11N  
D4B-2A11N  
D4B-3A11N  
D4B-4A11N  
D4B-5A11N  
D4B-6A11N  
D4B-7A11N  
D4B-8A11N  
D4B-1A15N  
D4B-2A15N  
D4B-3A15N  
D4B-4A15N  
D4B-5A15N  
D4B-1A70N  
D4B-2A70N  
D4B-3A70N  
D4B-4A70N  
D4B-5A70N  
D4B-6A70N  
D4B-7A70N  
D4B-8A70N  
D4B-1A71N  
D4B-2A71N  
D4B-3A71N  
D4B-4A71N  
D4B-5A71N  
D4B-6A71N  
D4B-7A71N  
D4B-8A71N  
G1/2 (PF1/2)  
1/2-14NPT  
D4B-2111N  
D4B-3111N  
D4B-4111N  
D4B-5111N  
D4B-6111N  
D4B-7111N  
D4B-8111N  
D4B-1115N  
D4B-2115N  
D4B-3115N  
D4B-4115N  
D4B-5115N  
D4B-1170N  
D4B-2170N  
D4B-3170N  
D4B-4170N  
D4B-5170N  
D4B-6170N  
D4B-7170N  
D4B-8170N  
D4B-1171N  
D4B-2171N  
D4B-3171N  
D4B-4171N  
D4B-5171N  
D4B-6171N  
D4B-7171N  
D4B-8171N  
M20  
Roller lever  
(resin roller)  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
M20 (3-conduit)  
Pg13.5  
G1/2 (PF1/2)  
1/2-14NPT  
Roller lever  
(stainless steel  
roller)  
M20  
Pg13.5 (3-conduit)  
Pg13.5  
G1/2 (PF1/2)  
1/2-14NPT  
M20  
Top plunger  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
M20 (3-conduit)  
Pg13.5  
G1/2 (PF1/2)  
1/2-14NPT  
M20  
Top roller plunger  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
M20 (3-conduit)  
2
D4B-@N  
General-purpose Limit Switches  
1NC/1NO (Snap-action)  
1NC/1NO (Slow-action)  
2NC (Slow-action)  
Actuator  
Conduit openings  
Direct  
Model  
Direct  
Model  
Direct  
opening  
Model  
opening  
opening  
Pg13.5  
D4B-1116N  
D4B-1516N  
D4B-1A16N  
D4B-2A16N  
D4B-3A16N  
D4B-5A16N  
D4B-6A16N  
D4B-7A16N  
D4B-1A17N  
D4B-2A17N  
D4B-3A17N  
D4B-5A17N  
D4B-6A17N  
D4B-7A17N  
D4B-1A81N  
D4B-2A81N  
D4B-3A81N  
D4B-5A81N  
D4B-6A81N  
D4B-7A81N  
D4B-1A87N  
D4B-2A87N  
D4B-3A87N  
D4B-5A87N  
D4B-6A87N  
D4B-7A87N  
G1/2 (PF1/2)  
D4B-2116N  
D4B-3116N  
D4B-5116N  
D4B-6116N  
D4B-7116N  
D4B-1117N  
D4B-2117N  
D4B-3117N  
D4B-5117N  
D4B-6117N  
D4B-7117N  
D4B-1181N  
D4B-2181N  
D4B-3181N  
D4B-5181N  
D4B-6181N  
D4B-7181N  
D4B-1187N  
D4B-2187N  
D4B-3187N  
D4B-5187N  
D4B-6187N  
D4B-7187N  
D4B-2516N  
D4B-3516N  
D4B-5516N  
D4B-6516N  
D4B-7516N  
D4B-1517N  
D4B-2517N  
D4B-3517N  
D4B-5517N  
D4B-6517N  
D4B-7517N  
1/2-14NPT  
Adjustable roller  
lever  
---  
---  
---  
---  
---  
---  
---  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
Pg13.5  
G1/2 (PF1/2)  
1/2-14NPT  
Adjustable rod  
lever  
---  
---  
---  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
Pg13.5  
G1/2 (PF1/2)  
1/2-14NPT  
Coil spring  
(non-directional)  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
Pg13.5  
---  
G1/2 (PF1/2)  
1/2-14NPT  
Plastic rod  
(non-directional)  
Pg13.5 (3-conduit)  
G1/2 (3-conduit)  
1/2-14NPT (3-conduit)  
Note: 1. In addition to the above models, models compatible with the previous D4B Switches (with standard rotary levers) are available.  
Model number examples: D4B-1@1RN(Pg13.5) or D4B-2@1RN(PF1/2)  
2. Consult your OMRON representative for products.  
3
D4B-@N  
Replacement Parts  
Switch Boxes  
Conduit  
1-conduit type  
G1/2  
3-conduit type  
G1/2  
Built-in switch  
PG13.5  
1/2-14NPT  
D4B-3100N  
PG13.5  
1/2-14NPT  
D4B-7100N  
1NC/1NO  
(Snap-action)  
D4B-1100N  
D4B-2100N  
D4B-2500N  
D4B-2A00N  
D4B-5100N  
D4B-6100N  
D4B-6500N  
D4B-6A00N  
1NC/1NO  
D4B-1500N  
D4B-1A00N  
D4B-3500N  
D4B-3A00N  
D4B-5500N  
D4B-5A00N  
D4B-7500N  
D4B-7A00N  
(Slow-action)  
2NC  
(Slow-action)  
Operating Heads  
Actuator  
Type  
Standard  
Plain  
Model  
D4B-0010N  
D4B-0070N  
Side rotary *  
Top plunger  
Top roller plunger D4B-0071N  
Coil spring  
Plastic rod  
D4B-0081N  
D4B-0087N  
Flexible-rod  
* The Lever is not included with the Side Rotary Operating Head.  
Levers  
Actuator  
Length (mm)  
Diameter of roller  
Model  
Standard  
31.5  
17.5 dia.  
17.5 dia.  
19 dia.  
---  
D4B-0001N  
D4B-0005N  
D4B-0006N  
D4B-0007N  
D4B-000RN  
Stainless steel roller lever  
Adjustable roller lever  
31.5  
25 to 89  
145 max.  
33.7  
Adjustable rod lever  
Interchangeable with D4B-0001  
19 dia.  
Note: Other types of lever are also available.  
4
D4B-@N  
Specifications  
Standards and EC Directives  
Conforms to the following EC Directives:  
Machinery Directive  
Low Voltage Directive  
EN1088  
EN50041  
Certified Standards  
Snap-action Models  
Slow-action Models  
Certification body  
Certification body  
Standard  
File No.  
Standard  
File No.  
EN60947-5-1  
EN60947-5-1  
(certified direct  
opening mechanism)  
GS-ET-15  
(certified direct  
opening mechanism)  
GS-ET-15  
J9851083  
J9851083  
TÜV Rheinland  
TÜV Rheinland  
EN60947-5-1  
(uncertified direct  
opening mechanism)  
EN60947-5-1  
(uncertified direct  
opening mechanism)  
J50005477 *  
J50005477 *  
UL  
UL508  
E76675  
UL  
UL508  
E76675  
CSA  
C22.2 No. 14  
GB14048.5  
LR45746  
CSA  
C22.2 No. 14  
GB14048.5  
LR45746  
CQC (CCC)  
2003010305077612  
CQC (CCC)  
2003010305077612  
* Adjustable roller lever, adjustable rod lever, coil spring, and plastic  
rod models only.  
* Adjustable roller lever, adjustable rod lever, coil spring, and plastic  
rod models only.  
Certified Standard Ratings  
TÜV (EN60947-5-1), CCC (GB14048.5)  
Item  
Utilization category AC-15  
Rated operating current (Ie)  
Rated operating voltage (Ue)  
2 A  
400 V  
Note: As protection against short-circuiting, use either a gI-type or gG-type 10 A fuse that conforms to IEC60269.  
UL/CSA: (UL508, CSA C22.2 No. 14)  
A600  
Current (A)  
Volt-amperes (VA)  
Make Break  
Rated voltage  
120 VAC  
240 VAC  
480 VAC  
600 VAC  
Carry current  
Make  
Break  
60  
30  
15  
12  
6
3
1.5  
1.2  
10 A  
7,200  
720  
5
D4B-@N  
Ratings  
Non-inductive load (A)  
Inductive load (A)  
Inductive load Motor load  
NC NO NO  
Rated voltage (V)  
Resistive load  
NC NO  
Lamp load  
NC  
NO  
NC  
125 VAC  
250  
400  
10  
10  
10  
3
2
1.5  
1.5  
1
0.8  
10  
10  
3
5
3
1.5  
2.5  
1.5  
0.8  
8 VDC  
14  
30  
10  
10  
6
6
6
4
3
3
3
10  
10  
6
6
6
4
125  
250  
0.8  
0.4  
0.2  
0.1  
0.2  
0.1  
0.8  
0.4  
0.2  
0.1  
Note: 1. The above values are continuous currents.  
2. Inductive loads have a power factor of 0.4 or higher (AC) or a time constant of 7 ms or lower (DC).  
3. Lamp loads have a inrush current of 10 times the normal current.  
4. Motor loads have a inrush current of 6 times the normal current.  
Inrush current  
30 A max.  
Characteristics  
Degree of protection *1  
IP67 (EN60947-5-1)  
30,000,000 operations min. (snap-action)  
10,000,000 operations min. (slow-action)  
Mechanical  
Electrical  
Durability *2  
500,000 operations min. (10 A resistive load at 250 VAC)  
1 mm/s to 0.5 m/s  
Operating speed  
Mechanical  
Electrical  
120 operations/minute  
Operating frequency  
Contact resistance  
30 operations/minute  
25 mΩ max.  
General load  
Gold-clad contact 20 mA resistive load at 5 VAC  
(N-level reference value)  
180 mA resistive load at 5 VAC  
Minimum applicable load *4  
Rated insulation voltage (Ui)  
Rated frequency  
600 V (EN60947-5-1)  
50/60 Hz  
Protection against electric shock  
Class I (with ground terminal)  
3 (EN60947-5-1)  
Pollution degree (operating environment)  
Between terminals  
of same polarity  
2.5 kV (snap-action)/4 kV (slow-action)  
Impulse withstand voltage Between terminals  
4 kV (slow-action)  
4 kV  
(EN60947-5-1)  
of different polarity  
Between each  
terminal and ground  
100 MΩ min. (at 500 VDC) between terminals of the same polarity and between each  
terminal and non-current-carrying part  
Insulation resistance  
2 × 2 mm min. (slow-action)  
2 × 0.5 mm min. (snap-action)  
Contact gap  
Vibration resistance  
Malfunction  
Destruction  
Malfunction  
10 to 55 Hz, 0.75 mm single amplitude  
1,000 m/s2 min.  
300 m/s2 min.  
Shock resistance  
Conditional short-circuit current  
Conventional enclosed thermal current (Ithe)  
Ambient operating temperature  
Ambient operating humidity  
Weight  
100 A (EN60947-5-1)  
20 A (EN60947-5-1)  
–40 to 80°C (with no icing) *3  
95% max.  
Approx. 250 g  
Note: 1. The above values are initial values.  
2. The above values may vary depending on the model. Consult your OMRON sales representative for details.  
*1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for  
the operating conditions and environment beforehand.  
*2. The durability is for an ambient temperature of 5 to 35°C and ambient humidity of 40% to 70%. For further conditions, consult your OMRON  
sales representative.  
*3. –20 to 80°C for the flexible-rod type.  
*4. The above values may vary depending on switching frequency, environmental condition, and relativity level, consult your OMRON sales  
representative.  
6
D4B-@N  
Engineering Data  
(Ambient temperature: 5 to 30°C, ambient humidity: 40 to 70%)  
Electrical Durability (Snap-action)  
(cosφ = 1)  
1,000  
(cosφ = 0.4)  
1,000  
Operating frequencies:  
30 times/min., cosφ = 0.4  
Operating frequencies:  
30 times/min., cosφ = 1  
500  
300  
500  
300  
125 VAC  
250 VAC  
480 VAC  
250 VAC  
100  
50  
100  
50  
30  
10  
30  
10  
500 VAC  
Switching current (A)  
Switching current (A)  
Structure and Nomenclature  
Structure  
Head  
Can be connected in any of four directions (except for  
Roller Plunger Models, which can be connected at either  
of 2 directions that differ by 90°)  
The roller lever switch employs a  
system which allows  
Roller  
selection of operation on only one  
side (left or right)  
Nylon rollers used for superior resistance to wear.  
or both sides without the use of  
any tools.  
Lever (Form Lock Structure)  
The lever has an operating position indication plate  
and grooves that mate every 90° to prevent slipping  
between the rotary axis and lever.  
Seal Ring  
Sealing properties improved by using a X ring and  
bearing-free structure.  
The operating position indicator plate  
Built-in Switch  
Direct opening mechanism used for NC contact to  
separate contact for faults, such as contact welding.  
The heights of the NC and NO terminals are different  
to enable easier wiring.  
Conduit Opening  
Models are available with a wide range of conduits.  
Size  
Box  
1-conduit model 2-conduit model  
Yes  
Yes  
Yes  
Pg13.5  
G1/2  
Yes  
Yes  
Yes  
Cover  
1/2-14NPT  
Ground Screw  
Ground screws are provided on all  
models for increased safety.  
Note: NBR is used for rubber parts.  
7
D4B-@N  
Direct Opening Mechanism  
1NO/1NC Contact (Snap-action)  
Conforms to EN60947-5-1 Direct Opening  
(Only NC contact has a direct opening mechanism.)  
1. When contact welding occurs.  
2. When contacts are being pulled apart.  
3. When contacts are completely  
pulled apart.  
Movable contact  
Safety cam directly  
pushes up the  
movable contact  
blade.  
Movable contact  
blade  
Plunger  
A
B
Safety cam  
Fixed contact (NC)  
1NC/1NO Contact (Slow-action)  
2NC Contact (Slow-action)  
Conforms to EN60947-5-1 Direct Opening  
Conforms to EN60947-5-1 Direct Opening  
(Both NC contacts have a direct opening mechanism.)  
When contact welding occurs, the contacts are separated  
from each other by the plunger being pushed in.  
(Only NC contact has a direct opening mechanism.)  
When contact welding occurs, the contacts are separated  
from each other by the plunger being pushed in.  
Fixed contact (NC)  
Fixed contact (NC)  
Movable contact  
Plunger  
Contact spring  
Contact spring  
Return spring  
Movable contact  
Plunger  
Return spring  
Fixed contact (NO)  
Contact Form  
Model  
Contact  
Contact form  
Diagrams  
Explanation  
Only NC contact 11-12 has a  
certified direct opening  
mechanism.  
Za  
11-12  
13-14  
13  
14  
12  
ON  
1NC/1NO  
(Snap-action)  
D4B-@1@N  
Terminal numbers 11-12 and  
13-14 cannot be used as unlike  
poles.  
Stroke  
11  
Only NC contact 11-12 has a  
certified direct opening  
mechanism.  
Zb  
11-12  
23-24  
11  
23  
12  
24  
1NC/1NO  
(Slow-action)  
ON  
D4B-@5@N  
D4B-@A@N  
Terminal numbers 11-12 or  
23-24 can be used as unlike  
poles.  
Stroke  
Both NC contacts 11-12 and  
21-22 have a certified direct  
opening mechanism.  
Zb  
11-12  
21-22  
11  
21  
12  
22  
2NC  
(Slow-action)  
ON  
Terminal numbers 11-12 and  
21-22 can be used as unlike  
poles.  
Stroke  
Note: Terminal numbers are according to EN50013; contact symbols are according to IEC60947-5-1.  
8
D4B-@N  
Dimensions and Operating Characteristics  
(Unit: mm)  
Note: Omitted dimensions are the same as those for the Roller Lever  
Type Models  
opening.  
D4B-3@@@N and D4B-7@@@N have a 1/2-14NPT conduit  
opening.  
D4B-1@@@N and D4B-5@@@N have a PG13.5 conduit  
opening. D4B-2@@@N and D4B-6@@@N have a G1/2 conduit  
1-conduit Models  
Switches  
Roller Lever  
D4B-@@11N  
Roller Lever (Stainless Steel Roller)  
D4B-@@15N  
62  
1
62  
1
17.5 dia. × 6.6 resin roller  
17.5 × 7 stainless steel roller  
56  
56  
16  
16  
M5 × 12  
Allen-head bolt  
M5 × 12  
Allen-head bolt  
28.3  
28.3  
Four, M3.5 × 19.5  
head  
mounting screws  
Four, M3.5 × 19.5  
head  
mounting screws  
31.5R  
31.5R  
Set position  
indicator plate  
*1  
Set position  
indicator plate *1  
22.5  
22.5  
23  
23  
11.5  
11.5  
131.3 1.2  
131.3 1.2  
Two, 5.3 dia.  
mounting holes  
Two, 5.3-dia.  
mounting holes  
99.5  
99.5  
Two, M4 × 12  
60 0.2  
Two, M4 × 12  
cover mounting  
screws  
77  
74  
77  
74  
60 0.2  
8
cover mounting  
Cover  
screws  
Cover  
7.3  
7.3  
8
5.3  
15  
31.5  
43  
5.3  
15  
Conduit opening  
Conduit opening  
30 0.2  
30 0.2  
31.5  
43  
40+1  
40+1  
0
0
Adjustable Rod Lever *2  
Adjustable Roller Lever *2  
D4B-@@16N  
71  
64.4  
53  
46.8  
1
66  
1
D4B-@@17N  
5.4  
56.8  
28.3  
16  
3 dia. × 160  
stainless steel  
rod  
19 dia. × 7  
resin roller  
16  
28.3  
Four, M3.5 × 24.5  
head  
mounting screws  
Four, M3.5 × 24.5  
head  
mounting screws  
145 max.  
Setting position  
indicator *1  
Set position  
indicator plate *1  
25 to 89R  
23  
1
2
3
M5 × 12  
Allen-head bolts  
22.5  
22.5  
M5 × 16  
Allen-head bolts  
23  
Two, 5.3-dia.  
mounting holes  
Two, 5.3-dia.  
99.5  
99.5  
mounting holes  
60 0.2  
77  
74  
77  
74  
60 0.2  
8
Two, M4 × 12 cover  
Two, M4 × 12 cover  
mounting screws  
mounting screws  
Cover  
Cover  
7.3  
7.3  
8
5.3  
15  
31.5  
43  
5.3  
15  
Conduit opening  
Conduit opening  
30 0.2  
30 0.2  
31.5  
43  
40+1  
40+1  
0
0
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
*1. The lever can be set to any desired position by turning the operating position indicator.  
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch.  
Model D4B-@@11N D4B-@@15N D4B-@@16N D4B-@@17N  
Operating characteristics  
*1  
*2  
Operating force  
Release force  
Pretravel  
OF max.  
RF min.  
PT  
PT (2nd) *3 *5  
OT min.  
9.41N  
1.47N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61N  
(75°)  
9.41N  
1.47N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61N  
(75°)  
9.41N  
1.47N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61N  
(75°)  
2.12N  
0.29N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61N  
(75°)  
Overtravel  
Movement differential MD max. *4  
Direct opening travel  
DOT min. *3 *6  
*4 *6  
DOF min. *6  
TT *5  
Direct opening force  
Total travel  
Note: Variation occurs in the simultaneity of contact opening/closing  
operations of 2NC contacts. Check contact operation.  
*1. The operating characteristics of these Switches were measured  
with the roller level set at 31.5 mm.  
*2. The operating characteristics of these Switches were measured  
with the rod level set at 140 mm.  
*3. Only for slow-action models.  
*4. Only for snap-action models.  
*5. Reference values.  
*6. Must be provided to ensure safe operation.  
9
D4B-@N  
Top Plunger  
Top Roller Plunger  
D4B-@@70N  
D4B-@@71N  
12.7 dia. × 4.8  
stainless steel roller  
PT  
16  
Four, M3.5 × 19.5  
head  
mounting screws  
16  
Four, M3.5 × 19.5  
head  
mounting screws  
9.2 dia.  
PT  
9.2 dia.  
Stainless steel  
plunger  
OP  
20  
OP  
20  
Two, 5.3-dia.  
Two, 5.3-dia.  
mounting holes  
mounting holes  
97  
97  
77  
74  
60 0.2  
Two, M4 × 12 cover  
mounting screws  
60 0.2  
8
Two, M4 × 12 cover  
mounting screws  
77  
74  
Cover  
Cover  
7.3  
7.3  
8
5.3  
15  
31.5  
43  
Conduit opening  
5.3  
15  
31.5  
43  
Conduit opening  
30 0.2  
30 0.2  
40+1  
40+1  
0
0
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
Operating characteristics  
Model  
D4B-@@70N  
18.63 N  
1.96 N  
2 mm  
D4B-@@71N  
18.63 N  
1.96 N  
2 mm  
Operating force  
Release force  
Pretravel  
OF max.  
RF min.  
PT max.  
Note: Variation occurs in the simultaneity of  
contact opening/closing operations of  
2NC contacts. Check contact  
operation.  
*1. Only for slow-action models.  
*2. Only for snap-action models.  
*3. Reference values.  
PT (2nd) *1 *3  
(3 mm)  
5 mm  
1 mm  
3.2 mm  
49.03 N  
(7 mm)  
(3 mm)  
5 mm  
1 mm  
3.2 mm  
49.03N  
(7 mm)  
Overtravel  
OT min.  
Movement differential MD max. *2  
Direct opening travel  
Direct opening force  
Total travel  
DOT min. *4  
DOF min. *4  
TT *3  
*4. Must be provided to ensure safe  
operation.  
Free position  
Operating position  
FP max.  
OP  
38 mm  
35 1 mm  
51 mm  
48 1 mm  
Coil Spring (Non-directional) *2  
D4B-@@81N  
Plastic Rod (Non-directional) *2  
D4B-@@87N  
Plastic rod  
Stainless steel coil spring  
The Switch can be  
The Switch can be  
actuated in any  
direction except to  
the axis center.  
actuated in any  
direction except to  
the axis center.  
(40) *1  
(40) *1  
6.6 dia.  
6.6 dia.  
15.7 16  
15.7 16  
18.2 dia.  
29.1  
18.2 dia.  
Seal cap  
Seal cap  
2.7  
77  
2.7  
77  
Four, M3.5 × 7  
head mounting  
screws  
203.5 1.2  
203.5 1.2  
29.1  
Four, M3.5 × 7  
mounting screws  
Two, 5.3-dia.  
mounting holes  
Two, 5.3-dia.  
mounting holes  
60 0.2  
8
Two, M4 × 12 cover  
mounting screws  
60 0.2  
74  
74  
Two, M4 × 12 cover  
mounting screws  
Cover  
7.3  
7.3  
8
Cover  
5.3  
15  
5.3  
30 0.2  
15  
Conduit  
Conduit  
opening  
opening  
30 0.2  
31.5  
43  
31.5  
43  
40+1  
40+1  
0
0
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
*1. Be sure to adjust the dog to within 40 mm from the top end of the coil spring.  
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch.  
Operating characteristics  
Model  
D4B-@@81N  
D4B-@@87N  
Note: Variation occurs in the simultaneity of  
contact opening/closing operations of  
2NC contacts. Check contact  
operation.  
Operating force  
Pretravel  
OF max.  
PT max.  
1.47 N  
15°  
1.47 N  
15°  
10  
D4B-@N  
3-conduit Switches  
Roller Lever  
Roller Lever  
D4B-@@11N  
D4B-@@15N  
62  
56  
1
17.5 dia. × 7  
stainless steel  
roller  
1
17.5 dia. x 6.6 resin roller  
M5 × 12  
Allen-head  
bolt  
M5 x 12  
Allen-head bolt  
31.5R  
Four, M3.5 x 24.5  
head  
mounting screws  
28.3  
1
16  
Four, M3.5 × 24.5  
head  
mounting screws  
31.5R  
Operating position  
indicator *1  
Operating position  
indicator *1  
22.5  
40 to 42  
40 to 42  
23  
5.3  
11.5  
129.7 1.2  
Six, 5.3-dia.  
mounting holes  
Six, 5.3 dia.  
mounting holes  
30 0.2  
97.9  
Four, M3.5 x 10  
cover mounting screws  
Four, M3.5 × 10 cover  
mounting screws  
18  
50.9  
75.4  
59.3 0.2  
71.4  
66.4  
Two, caps  
Two, caps  
Cover  
Cover  
17.2  
Two, 5+0.15 -dia.  
Two, 5+0.15 -dia.  
0
27 0.2  
51  
28.5  
0
3-conduit opening  
3-conduit opening  
35.7  
38.8  
holes (depth: 6)  
holes (depth: 6)  
57  
63  
Adjustable Roller Lever *2  
D4B-@@16N  
Adjustable Rod Lever *2  
D4B-@@17N  
19 dia. x 7 resin roller  
3 dia. x 160  
stainless steel rod  
Four, M3.5 x 24.5  
head  
mounting screws  
Four, M3.5 x 24.5  
head  
mounting screws  
Operating  
position  
indicator *1  
145 max.  
Operating position  
25 to 89R  
indicator *1  
40 to 42  
M5 x 12  
Allen-head  
bolts  
M5 x 16  
Allen-head  
bolts  
40 to 42  
Six, 5.3-dia.  
Mounting holes  
Four, M3.5 x 10 Cover  
mounting screws  
Six, 5.3-dia.  
mounting holes  
Four, M3.5 x 10 cover  
mounting screws  
Two, caps  
66.4  
Two, caps  
Cover  
Cover  
Two, 5+0.15 -dia.  
Two, 5 +0.15 -dia.  
0
holes (d0epth: 6)  
3-conduit opening  
3-conduit opening  
holes (depth: 6)  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
*1. The lever can be set to any desired position by turning the operating position indicator.  
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch.  
D4B-@@11N D4B-@@15N D4B-@@16N D4B-@@17N  
Model  
Operating characteristics  
*1  
*2  
Operating force  
Release force  
Pretravel  
OF max.  
RF min.  
PT  
PT (2nd) *3 *5  
OT min.  
9.41 N  
1.47 N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61 N  
(75°)  
9.41 N  
1.47 N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61 N  
(75°)  
9.41 N  
1.47 N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61 N  
(75°)  
2.12 N  
0.29 N  
21° 3°  
(45°)  
50°  
12°  
35°  
55°  
19.61 N  
(75°)  
Overtravel  
Movement differential MD max. *4  
Direct opening travel  
DOT min. *3 *6  
*4 *6  
DOF min. *6  
TT *5  
Direct opening force  
Total travel  
Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC contacts. Check contact operation.  
*1. The operating characteristics of these Switches were measured with the roller level set at 31.5 mm.  
*2. The operating characteristics of these Switches were measured with the rod level set at 140 mm.  
*3. Only for slow-action models.  
*4. Only for snap-action models.  
*5. Reference values.  
*6. Must be provided to ensure safe operation.  
11  
D4B-@N  
Top Plunger  
D4B-@@70N  
Top Roller Plunger  
D4B-@@71N  
Four, M305 x 1905  
head  
mounting screws  
Four, M305 x 1905  
head  
mounting screws  
1207 dia0 x .08  
stainless steel roller  
902 dia0  
902 dia0  
Stainless steel  
plunger  
.± to .2  
.± to  
.2  
Six, 503-dia0  
Six, 503-dia0  
mounting screws  
mounting holes  
950.  
Four, M305 x 1±  
cover mounting screws  
Four, M305 x 1± cover  
mounting screws  
Two, caps  
Cover  
Two, caps  
Cover  
Two, 5 +±015 -dia0  
Two, 5 +±015 -dia0  
holes (d±epth: 6)  
holes (d±epth: 6)  
3-conduit opening  
3-conduit opening  
Note: Unless otherwise specified, a tolerance of ±±0. mm applies to all dimensions0  
Operating characteristics Model D4B-@@70N D4B-@@71N  
18063 N 18063 N  
Operating force  
Release force  
Pretravel  
OF max.  
Note: Variation occurs in the simultaneity of  
contact opening/closing operations of  
2NC contacts0 Check contact  
operation0  
*1. Only for slow-action models0  
*2. Only for snap-action models0  
*3. Reference values0  
RF min.  
PT max.  
1096 N  
2 mm  
1096 N  
2 mm  
PT (2nd) *1 *3  
(3 mm)  
5 mm  
1 mm  
302 mm  
.90±3 N  
(7 mm)  
(3 mm)  
5 mm  
1 mm  
302 mm  
.90±3N  
(7 mm)  
Overtravel  
OT min.  
Movement differential MD max. *2  
Direct opening travel DOT min. *4  
Direct opening force  
Total travel  
DOF min. *4  
TT *3  
*4. Must be provided to ensure safe  
operation0  
Free position  
Operating position  
FP max.  
OP  
38 mm  
35±1 mm  
51 mm  
.8±1 mm  
Coil Spring *2  
D4B-@@81N  
Plastic Rod *2  
D4B-@@87N  
Plastic rod  
The Switch can be actuated  
to all directions except to the  
Stainless steel coil spring  
axis center0  
(.±) *1  
The Switch can be actuated  
to all directions except to  
the axis center  
(.±) *1  
606 dia0  
606 dia0  
1802 dia0  
Seal cap  
1802 dia0  
Four, M305 x 7  
.± to .2  
2±109±102  
Seal cap  
head mounting screws  
Four, M305 x 7  
.± to .2  
head mounting screws  
Six, 503-dia0  
mounting holes  
Four, M305 x 1±  
cover mounting screws  
Two, caps  
Six, 503-dia0  
mounting holes  
Four, M305 x 1± cover  
mounting screws  
Cover  
Two, caps  
Cover  
Two, 5+±015 -dia0  
±
3-conduit opening  
Two, 5+±015 -dia0  
holes (depth: 6)  
±
3-conduit  
opening  
holes (depth: 6)  
Note: Unless otherwise specified, a tolerance of ±±0. mm applies to all dimensions0  
*1. Be sure to adjust the dog to within .± mm from the top end of the coil spring0  
*2. In terms of construction, the Switch is a General-purpose Limit Switch rather than a Safety Limit Switch0  
Operating characteristics  
Model  
D4B-@@81N  
10.7 N  
15°  
D4B-@@87N  
10.7 N  
15°  
Operating force  
Pretravel  
OF max.  
PT max.  
Note: Variation occurs in the simultaneity of  
contact opening/closing operations of  
2NC contacts0 Check contact  
operation0  
12  
D4B-@N  
Levers (Applicable for Roller Lever Models only)  
Roller Lever  
D4B-0001N  
Roller Lever  
Adjustable Roller Lever  
D4B-0006N  
Adjustable Rod Lever  
(Stainless Steel Roller)  
26  
D4B-0007N  
3 dia.  
21.6  
12.5  
D4B-0005N  
17.5 dia. × 7  
stainless steel roller  
20.2  
19 dia. x 7 nylon roller  
17  
12  
17  
Stainless rod  
12.8  
6.4  
adjusting  
11.8  
17.5 dia. x 6.8 nylon roller  
scale  
Adjustable  
145  
max.  
range  
(25 to 89)  
M5 hexagon  
socket head  
screw  
5.4  
160  
31.5  
31.5R  
97  
M5 hexagon  
socket head  
screw  
M5 hexagon  
socket head  
screw (length: 12)  
28  
7.3 dia.  
15  
M5 hexagon  
socket head  
screw  
15  
11.5  
11.5  
3.2  
11  
15.9  
20  
17  
Roller Lever  
WL-1A118  
Roller Lever  
WL-1A106  
Roller Lever (Compatible with  
Previous D4B Model)  
D4B-000RN  
40.2 0.8  
17.8  
17.5 dia. × 30  
nylon roller  
19 dia. x 7 nylon roller  
12  
23.6  
20.1 0.8  
50 dia. × 6 nylon roller  
7.3+0.1 dia.  
0
33.7  
38  
54.8  
7.3 dia.  
M5 hexagon  
socket head screw  
7.3 dia.  
M5 hexagon  
socket head  
screw  
12  
18  
11.5  
M5 hexagon socket  
head screw (length: 12)  
16  
11.4  
Note: Reverse the indicator plate when mounting.  
Note: Reverse the indicator plate when mounting.  
Roller Lever  
WL-1A300  
Roller Lever  
WL-1A400  
17.9  
17.5 dia. × 7  
stainless  
12.6  
steel roller  
16.9  
17 dia. × 6 bearing roller  
12.1  
63 0.3  
79.8  
7.3+0.1 dia.  
---  
0
54.3  
38  
7.3 dia.  
M5 hexagon  
socket head  
screw  
M5 hexagon  
socket head  
screw (length: 12)  
11.5  
16  
16  
11.4  
Note: Reverse the indicator plate when mounting.  
Note: Reverse the indicator plate when mounting.  
Spring Rod Lever  
WL-4A201  
Adjustable Rod Lever  
WL-3A100  
Resin Loop Lever  
D4A-F00  
150 10  
400 2  
7.3 dia.  
9
Adjustable range (350 to 380)  
7.3 dia.  
2 dia. stainless  
steel spring  
12.8  
(23.6)  
60 10  
8.0 0.4  
13 dia.  
6
11  
7.5  
65 2  
Adjustable  
range  
(290 max.)  
6
11  
7.5  
3.2 dia. stainless steel  
operation rod  
M5 × 16 hexagon  
socket head screw  
M5 hexagon socket head screws  
4 dia.  
25 max.  
13.8  
25.5  
max.  
13.4  
Nylon  
5.5  
33  
5.5  
M5 hexagon socket head screw  
M5 hexagon socket head screw  
Note: Reverse the indicator plate  
when mounting.  
Note: Reverse the indicator plate when mounting.  
Note: Reverse the indicator plate when mounting.  
Note: 1. Unless otherwise specified, a tolerance of ±0.4 mm applies  
to all dimensions.  
2. Safety Limit Switch specifications are satisfied with D4B-@@@@N Levers only (example: D4B-0001N).  
The D4B-0006N Adjustable Roller Lever and D4B-0007N Adjustable Rod Lever, however, cannot be used. Do not order them for a Side  
Rotary Operating Head.  
13  
D4B-@N  
Application Precaution  
Operating section  
(on back of Head)  
Changing the Operating Direction  
Switches with Roller Levers  
Operating procedure  
The operating direction of the lever can be easily  
changed without using any tools. It can be set to  
clockwise operation (CW) or counterclockwise  
(CCW) operation.  
Use the procedure given at the right to change  
the operating direction.  
1. Remove the four Head set screws and remove the Head  
from the Switch Box.  
Operating  
position  
mark  
Head Cover  
2. Turn the bottom of the Head toward you, press in the Head  
Cover shown in the diagram at the left, and turn the Cover  
clockwise or counterclockwise.  
(arrow)  
Note: The factory setting is for “CW.CCW.”  
3. The “CW” setting is for clockwise operation and the “CCW”  
setting is for counterclockwise operation. Set the Cover to  
the desired position.  
Safety Precautions  
Refer to the “Precautions for All Switches” and “Precautions for All Safety Limit Switches”.  
Mounting  
Precautions for Safe Use  
Use four M5 screws with washers to mount the standard model. Be  
Do not use the Switch submerged in oil or water, or in locations  
continuously subject to splashes of oil or water. Doing so may  
result in oil or water entering the Switch interior. (The IP67 degree  
of protection specification for the Switch refers to water penetration  
while the Switch is submersed in water for a specified period of  
time.)  
Always attach the cover after completing wiring and before using  
the Switch. Also, do not turn ON the Switch with the cover open.  
Doing so may result in electric shock.  
sure to apply the proper torque to tighten each screw. The 3-conduit  
models can be mounted more securely by using the four screws plus  
two 50.105 mm diameter studs, each of which has a maximum height  
of 4.8 mm as shown below.  
Mounting Dimensions (M5)  
3-conduit Model  
Standard Model  
Precautions for Correct Use  
Appropriate Tightening Torque  
(3)  
60  
30  
59.3 0.1  
40  
(6)  
42  
Studs  
27 0.1  
Be sure to tighten each  
(4)  
screw of the D4B-@N  
properly, otherwise the  
0.05  
5
dia. height: 5 max.  
0.15  
30  
D4B-@N may malfunction.  
(1)  
Changes in Actuator Mounting Position  
To change the angle of the lever, loosen the Allen-head bolts on  
the side of the lever.  
The operating position indicator plate * has protruding parts which  
engage with the lever, thus allowing changes to the lever position  
by 90°.  
(5)  
(2)  
The back of the operating position indicator plate * has no  
protruding parts. If this plate is turned over and attached, any angle  
within a 360° range can be set. Do not turn over the plate, however,  
when using the D4B-@N as a switch with a certified direct opening  
mechanism. For an SUVA- or BIA-certified application, make sure  
that the lever engages with the operating position indicator plate  
securely so that the lever will not slip.  
Appropriate tightening  
torque  
Type  
1
2
3
4
5
M3.5 terminal screw  
Cover mounting screw *  
Head mounting screw  
M5 body mounting screw  
Connector  
0.59 to 0.78 N·m  
1.18 to 1.37 N·m  
0.78 to 0.88 N·m  
4.90 to 5.88 N·m  
1.77 to 2.16 N·m  
* The operating position indicator plate: Refer to page 7.  
Changes in Head Mounting Position  
By removing the screws on the four corners of the head, the head can  
be reset in any of four directions. Make sure that no foreign materials  
will penetrate through the head.  
Lever Mounting Screws (Roller  
Levers)  
6
4.90 to 5.88 N·m  
1.27 to 1.67 N·m  
Cap screw  
(for three-conduit models)  
---  
* Apply a tightening torque of 0.78 to 0.88 N·m to three-conduit  
models.  
14  
D4B-@N  
Wiring  
Conduit Opening  
Do not connect the bare lead wires directly to the terminals but be  
sure to connect each of them by using an insulation tube and M3.5  
round crimp terminals and tighten each terminal screw within the  
specified torque range.  
Make sure that each connector is tightened within the specified  
torque range.  
The casing may be damaged if the connector is tightened  
excessively.  
If the 1/2-14NPT is used, cover the cable and conduit end with  
sealing tape in order to ensure IP67.  
The proper lead wire is 20 to 14 AWG (0.5 to 2.5 mm2) in size.  
The Pg13.5 connector must be Nippon Flex’s ABS-08 Pg13.5 or  
ABS-12 Pg13.5.  
Use an OMRON SC-series Connector (sold separately) that is  
suited to the cable in diameter.  
Properly attach the provided conduit cap to the unused conduit  
opening and securely tighten the cap screw within the specified  
torque when wiring the D4B-@N.  
dz dia.: 3.7 mm  
D dia.: 4.5 mm  
B:  
L:  
F:  
l:  
7.0 mm  
20.2 mm  
7.7 mm  
9.0 mm  
D dia.  
dz dia.  
Make sure that all crimp terminals come into contact with the casing  
or cover as shown below, otherwise the cover may not be mounted  
properly or the D4B-@N may malfunction.  
Others  
The load for the actuator (roller) of the Switch must be imposed on  
the actuator in the horizontal direction, otherwise the actuator or  
the rotating axis may be deformed or damaged.  
Correct  
Incorrect  
Terminal screw  
Correct  
Incorrect  
Dog  
Dog  
Crimp terminal  
Incorrect  
Correct  
When using a long lever model like the D4B-@@16N or D4B-@@17N,  
the Switch may telegraph. To avoid telegraphing, take the following  
precautions.  
Terminal screw  
Terminal screw  
Crimp  
terminal  
Cover  
Cover  
1. Set the lever to operate in one direction.  
2. Modify the rear end of the dog to an angle of 15° to 30° as  
shown below or to a secondary-degree curve.  
Casing  
Crimp terminal  
Casing  
θ
θ
15° ≤ θ ≤ 30°  
θ 30°  
3. Modify the circuit so as not to detect the wrong operating  
Correct  
Crimp terminal  
signals.  
Incorrect  
Crimp terminal  
Ordering Method  
The D4B-@N uses a block mounting  
Individual model numbers  
method. Switches can be ordered either as  
sets or as individual parts. If a set is  
ordered, the Switch will be shipped with all  
parts assembled.  
+
+
+
+
Set model number  
Switch Box  
Head  
Lever *  
Example: D4B-2111N  
D4B-2100N  
D4B-0010N  
D4B-0001N  
Note: For Switches with Roller Levers, do  
not order just the Head and Lever, or  
just the Switch Box and Lever.  
*Roller Levers only.  
15  
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2011.3  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2011 All Right Reserved.  

相关型号:

D4B-1A11N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1A15N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1A16N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1A17N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1A1RN

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1A70N

Snap Acting/Limit Switch, DPST, Momentary, 10A, 14VDC, 7mm, Screw Terminal, Top Plunger Actuator, Panel Mount
OMRON

D4B-1A71N

Snap Acting/Limit Switch, DPST, Momentary, 10A, 14VDC, 7mm, Screw Terminal, Top Roller Plunger Actuator, Panel Mount
OMRON

D4B-1A81N

Snap Acting/Limit Switch, DPST, Momentary, 10A, 14VDC, Screw Terminal, Coil Spring Type Actuator, Panel Mount
OMRON

D4B-1A87N

Snap Acting/Limit Switch, DPST, Momentary, 10A, 14VDC, Screw Terminal, Plastic Rod Actuator, Panel Mount
OMRON

D4B-1B11N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1B15N

Snap-action contact with certified direct opening operation certification
OMRON

D4B-1B16N

Snap-action contact with certified direct opening operation certification
OMRON