D2HW-C232D [OMRON]
Snap Acting/Limit Switch;型号: | D2HW-C232D |
厂家: | OMRON ELECTRONICS LLC |
描述: | Snap Acting/Limit Switch |
文件: | 总8页 (文件大小:1274K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
D2HW
Sealed Ultra Subminiature Basic Switch
Smallest sealed snap-action
switch in the industry with a
very long stroke for reliable
ON/OFF action
● The case dimensions are 78% of conventional
models, contributing to down-sizing of
mechanical modules.
● Extra-long stroke even without levers.
(OT reference value: 1.4 mm).
D
2
H
W
● Made of environmentally-friendly materials.
All models are lead-free, including molded lead
wire models.
RoHS Compliant
Model Number Legend
1
2
3
4
5
D2HW-
@@@@@
1. Mounting Structure
A :Without posts (base-mounting)
BR :Post on right
4. Contact form
1 : SPDT
2 : SPST-NC (Molded lead wire models only)
3 : SPST-NO (Molded lead wire models only)
BL :Post on left
C :M3-screw mounting models
5. Terminals
2. Raitings
2 : 5 VDC 1mA to 12 VDC 2A
D, DS : PCB terminals (Straight)
DR, DRS : PCB Terminals (Right-angled)
DL, DLS : PCB Terminals (Left-angled)
H, HS : Solder terminals
3. Actuator
0 : Pin plunger
M, MS : Molded lead wires downwards
MR, MRS: Molded lead wires on right-side
ML, MLS : Molded lead wires on left-side
1 : Hinge lever
2 : Long hinge lever
3 : Simulated roller lever
4 : Hinge roller lever
6 : Leaf lever
Note. UL/CSA approved versions are available.
In this case, a "S" will be added to the end of the model number.
The Lead wire is a UL approved wire (AWG24, UL1007).
7 : Simulated roller leaf lever
8 : Long leaf lever
1
D2HW
Sealed Ultra Subminiature Basic Switch
List of Models
●PCB-mounted Models
List of Models
Contact form
With posts on right
With posts on left
Without posts
D2HW-A201D
Actuator
Terminals
Straight
-
-
Pin plunger
D2HW-BR201DR
D2HW-BL201DL
-
Angled
Straight
Angled
Straight
Angled
Straight
Angled
-
-
D2HW-A211D
Hinge lever
D2HW-BR211DR
D2HW-BL211DL
-
For PCB
SPDT
-
-
D2HW-A221D
Long hinge
lever
D2HW-BR221DR
-
D2HW-BR231DR
D2HW-BL221DL
-
D2HW-BL231DL
-
D2HW-A231D
-
Simulated roller
hinge lever
D
2
H
W
Note1. Angled terminals and posts are the same direction.
Note2. "S" is added to the end of the model number for the UL/CSA-approved version Consult your OMRON sales representative for details.
●Models with Solder Terminals or Molded Lead Wires
List of Models
M3-screw
mounting
With posts on right
With posts on left
Actuator
Terminals
Contact form
SPDT
SPDT
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Solder
D2HW-BR201H
D2HW-BR201M
D2HW-BR202M
D2HW-BR203M
D2HW-BR202MR
D2HW-BR203MR
D2HW-BR202ML
D2HW-BR203ML
D2HW-BR211H
D2HW-BR211M
D2HW-BR212M
D2HW-BR213M
D2HW-BR212MR
D2HW-BR213MR
D2HW-BR212ML
D2HW-BR213ML
D2HW-BR221H
D2HW-BR221M
D2HW-BR222M
D2HW-BR223M
D2HW-BR222MR
D2HW-BR223MR
D2HW-BR222ML
D2HW-BR223ML
D2HW-BR231H
D2HW-BR231M
D2HW-BR232M
D2HW-BR233M
D2HW-BR232MR
D2HW-BR233MR
D2HW-BR232ML
D2HW-BR233ML
D2HW-BR241H
D2HW-BR241M
D2HW-BR242M
D2HW-BR243M
D2HW-BR242MR
D2HW-BR243MR
D2HW-BR242ML
D2HW-BR243ML
D2HW-BR261H
D2HW-BR261M
D2HW-BR262M
D2HW-BR263M
D2HW-BR262MR
D2HW-BR263MR
D2HW-BR262ML
D2HW-BR263ML
D2HW-BR271H
D2HW-BR271M
D2HW-BR272M
D2HW-BR273M
D2HW-BR272MR
D2HW-BR273MR
D2HW-BR272ML
D2HW-BR273ML
D2HW-BR281M
D2HW-BR282M
D2HW-BR283M
-
D2HW-BL201H
D2HW-BL201M
D2HW-BL202M
D2HW-BL203M
D2HW-BL202MR
D2HW-BL203MR
D2HW-BL202ML
D2HW-BL203ML
D2HW-BL211H
D2HW-BL211M
D2HW-BL212M
D2HW-BL213M
D2HW-BL212MR
D2HW-BL213MR
D2HW-BL212ML
D2HW-BL213ML
D2HW-BL221H
D2HW-BL221M
D2HW-BL222M
D2HW-BL223M
D2HW-BL222MR
D2HW-BL223MR
D2HW-BL222ML
D2HW-BL223ML
D2HW-BL231H
D2HW-BL231M
D2HW-BL232M
D2HW-BL233M
D2HW-BL232MR
D2HW-BL233MR
D2HW-BL232ML
D2HW-BL233ML
D2HW-BL241H
D2HW-BL241M
D2HW-BL242M
D2HW-BL243M
D2HW-BL242MR
D2HW-BL243MR
D2HW-BL242ML
D2HW-BL243ML
D2HW-BL261H
D2HW-BL261M
D2HW-BL262M
D2HW-BL263M
D2HW-BL262MR
D2HW-BL263MR
D2HW-BL262ML
D2HW-BL263ML
D2HW-BL271H
D2HW-BL271M
D2HW-BL272M
D2HW-BL273M
D2HW-BL272MR
D2HW-BL273MR
D2HW-BL272ML
D2HW-BL273ML
D2HW-BL281M
D2HW-BL282M
D2HW-BL283M
-
D2HW-C201H
D2HW-C201M
D2HW-C202M
D2HW-C203M
D2HW-C202MR
D2HW-C203MR
-
Downwards
Pin plunger
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C211H
D2HW-C211M
D2HW-C212M
D2HW-C213M
D2HW-C212MR
D2HW-C213MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Hinge lever
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C221H
D2HW-C221M
D2HW-C222M
D2HW-C223M
D2HW-C222MR
D2HW-C223MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Long hingelever
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C231H
D2HW-C231M
D2HW-C232M
D2HW-C233M
D2HW-C232MR
D2HW-C233MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Simulated roller
hinge lever
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C241H
D2HW-C241M
D2HW-C242M
D2HW-C243M
D2HW-C242MR
D2HW-C243MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Hinge roller
lever
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C261H
D2HW-C261M
D2HW-C262M
D2HW-C263M
D2HW-C262MR
D2HW-C263MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
Leaf lever
Molded
lead wires
Right-side
Left-side
-
Solder
D2HW-C271H
D2HW-C271M
D2HW-C272M
D2HW-C273M
D2HW-C272MR
D2HW-C273MR
-
SPDT
Downwards
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPST-NC
SPST-NO
SPDT
SPST-NC
SPST-NO
SPST-NC
SPST-NO
Simulated roller
leaf lever
Molded
lead wires
Right-side
Left-side
-
D2HW-C281M
D2HW-C282M
D2HW-C283M
D2HW-C282MR
D2HW-C283MR
Downwards
Right-side
Molded
lead wires
Long leaf lever
-
-
Note1. The length of standard lead wires (AVSS 0.5) for molded lead wire models shown above is 30 cm.
Note2. "S" is added to the end of the model number for the UL/CSA-approved version The lead wire models are UL approved wires (AWG24, UL1007). Consult your
OMRON sales representative for details.
2
D2HW
Sealed Ultra Subminiature Basic Switch
Contact form
●SPDT
● SPST-NC, (Molded Lead Wire
● SPST-NO, (Molded Lead Wire
Models Only)
Models Only)
Molded lead wire colors
are indicated in
COM
NO NC
(Black) (Blue)(Red)
COM
(Black)
NC
(Red)
COM
NO
parentheses.
(Black) (Blue)
D
2
H
W
Contact Specifications
Characteristics
Specification
Crossbar
Permissible operating speed
Permissible operating frequency
Insulation resistance
1 mm to 500 mm/s (for pin plunger models)
30 operations/min
Contact
Material
Gold alloy
0.5 mm
Gap (standard value)
100 MΩ min. (at 500 VDC with insulation tester)
Minimum applicable load (see note)
5 VDC 1mA
Contact
resistance
(initial value)
Terminals
100 m
Ω
Ω
max.
max.
Molded lead wire models
150 m
Ratings
Between terminals of the
same polarity
600 VAC 50/60 Hz 1min
Rated voltage
125 VAC
Resistive load
0.1A
Between current-carrying
metal parts and ground
Dielectric
strength
1,500 VAC 50/60 Hz 1 min
12 VDC
24 VDC
42 VDC
2A
1A
0.5A
Between terminals and
non-current-carrying metal
parts
1,500 VAC 50/60 Hz 1 min
Vibration
resistance * 1
Note. The above rating values apply under the following test conditions.
(1) Ambient temperature: 20 2°C
Malfunction
10 to 55 Hz, 1.5 mm double amplitude
(2) Ambient humidity: 65 5 %
(3) Operating frequency: 30 operations/min
Durability
1,000 m/s2 {approx. 100G} max.
300 m/s2 {approx. 30G} max.
Shock
resistance
Malfunction * 1
Mechanical
1,000,000 operations min. (30 operations/min)
100,000 operations min. (20 operations/min)
IEC IP67 (excluding the terminals on terminal models)
IEC IP67
Approved Safety Standard
Durability * 2
Electrical
Consult your OMRON sales representative for specific models
with standard approvals.
Terminals
Degree of
protection
molded lead wire models
UL (UL1054/CSA C22.2 No.55)
-40 to
+
85°C (at ambient humidity of 60% max.)
(with no icing or condensation)
Ambient operating temperature
Model
Item
D2HW
Resistive load
0.1A
Ambient operating humidity
Weight
95% max. (for +5 to +35°C)
Rated voltage
125 VAC
12 VDC
Approx. 0.7 g (for pin plunger models with terminals)
2A
Note. The data given above are initial values.
*1. For the pin plunger models, the above values apply for use at the free
position, operating position, and total travel position. For the lever models,
they apply at the total travel position. Close or open circuit of the contact
is 1ms max.
*2. For testing conditions, consult your OMRON sales representative.
Mounting Structure and Reference Positions for Operating Characteristics (Unit: mm)
●Without posts
D2HW-A@
●Models with Posts
D2HW-B@
●M3-screw Mounting Models
D2HW-C@
0.1
2.65
4
8
0.1
13
1.7 dia.
1.7 dia.
0
3-0.1 dia.
0.15
3.3
dia.
6.5
0.05
FP OP
2.6
FP
OP
TTP
TTP
3
FP
OP
6
TTP
Standard
Position
7
6.5
Standard
Position
+0.13
3.1
-0.03
Standard Position
18.5
13.3
5ꢀ0
5.3
5.3
13.3
5.3
ࠉ
-0.2 0
0
1.5 -0.1
1.5 -0.1
Mounting Hole Dimensions (Reference)
Mounting Hole Dimensions (Reference)
2.4+0.1 dia. holes
(dep0th: 5 mm min.)
2.6
3+0.1 dia. holes
0
(depth: 1.5 mm min.)
M3 Tap
2.4+0.1
ࠉ
ࠉ
0 0.1
8
0.1
13
Note. The reference positions used for Free Position (FP), Operating Position (OP), and Total Travel Position (TTP) values are as shown above for each type of
mounting.
3
D2HW
Sealed Ultra Subminiature Basic Switch
Terminals/Appearances (Unit: mm)
●PCB terminals (Straight)
●PCB Terminals (Left-angled)
●PCB terminals (Right-angled)
6
6
2.5
3-0.6
3-0.6
3-0.6
0.5
0.5
0.5
㸦3.1㸧
㸦3.1㸧
5.08
5.08
5.08
5.08
5.08
5.08
<PCB Cutout Dimensions (Reference)>
<PCB Mounting Dimensions (Reference)>
D
2
H
W
0.1
8
3-1+0.1 dia. holes
0
2.4+0.1 dia. holes
(dept0h: 5 mm min.)
2.6
2.4+0.1
ࠉ
ࠉ
0
0.1
0.1
5.08
5.08
0.1
6
3-1+0.1 dia. holes
0
0.1
0.1
5.08
5.08
●Solder terminals
3.5
1.8
1.2
3-2
0.5
4.38 4.38
●Molded Lead Wires on Left-side
●Molded Lead Wires on Right-side
●Molded Lead Wires Downwards
NC AVSS 0.5 (Red)*
Or
COM AVSS 0.5 (Black)*
NO AVSS 0.5 (Blue)
NC AVSS 0.5 (Red)
or
NO AVSS 0.5 (Blue)
COM AVSS 0.5 (Black)
㸦12㸧
㸦12㸧
㸦12㸧
㸦5㸧
㸦5㸧
10
300
㸦13.3㸧
10
300
㸦13.3㸧
*
COM AVSS 0.5 (Black)
NO AVSS 0.5 (Blue)
NC AVSS 0.5 (Red)
UL approved wires (AWG24, UL1007) are
used for UL/CSA standard approved items.
UL approved wires (AWG24, UL1007) are
used for UL/CSA standard approved items.
*
*
10
300
㸦5㸧
UL approved wires (AWG24, UL1007) are
used for UL/CSA standard approved items.
*
4
D2HW
Sealed Ultra Subminiature Basic Switch
Dimensions (Unit: mm) /Operating Characteristics
The following illustrations and drawings are representative models. When ordering, replace @ with the code for the mounting structure, contact form and terminal that
you need.
See the "■List of Models" for available combinations of appearances.
Refer to page 3 to 4 for the mounting structures and terminal forms.
●Pin plunger
D2HW-@20@@
M3-screw
Mounting
Models
4
Without
posts
Modelswith
Posts
Operating characteristics
Type
1.7 dia.
A
Operating Force
Releasing Force
OF
RF
Max.
Min.
0.75N {76 gf}
0.10N {10 gf}
FP
OP
Overtravel
Movement Differential
OT
MD
1.4 mm (reference value)
0.25 mm
TTP
D
2
H
W
7
Max.
Max.
Free Position
Operating Position
Total Travel Position
FP
OP
TTP Max.
11.2 mm
10.4 0.2 mm
9.1 mm
7.2 mm
6.4 0.2 mm
5.1 mm
5.3
3.4
●Hinge Lever
D2HW-@21@@
M3-screw
Mounting
Models
Without
posts
Models
with Posts
Operating characteristics
Type
A
t0.3
13
Stainless-steel lever
Operating Force
Releasing Force
OF Max.
RF Min.
0.75N {76 gf}
0.07N {7 gf}
㸦1.15㸧
FP
OP
Overtravel
Movement Differential MD Max.
OT
1.6 mm (reference value)
0.5 mm
TTP
㸦0.4㸧
7
Free Position
Operating Position
Total Travel Position
FP Max. 12.8 mm
8.8 mm
7.5 0.5 mm
6 mm
OP
11.5 0.5 mm
10 mm
TTP Max.
●Long Hinge Lever
D2HW-@22@@
M3-screw
Mounting
Models
Operating
characteristics
Without
posts
Models
with Posts
Type
A
3.4
20
t0.3
Stainless-steel lever
Operating Force
Releasing Force
OF Max.
RF Min.
0.5N {50 gf}
0.03N {3 gf}
㸦1.15㸧
Overtravel
Movement Differential MD Max.
OT
2.5 mm (reference value)
0.8 mm
FP
OP
TTP
㸦0.4㸧
7
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP Max.
15.5 mm
11.5 mm
9.3 0.8 mm
7 mm
13.3 0.8 mm
11 mm
●Simulated Roller Lever
D2HW-@23@@
M3-screw
Mounting
Models
Operating
characteristics
Without
posts
Models
with Posts
Type
A
3.4
R2
15
t0.3 Stainless-steel lever
Operating Force
Releasing Force
OF Max.
RF Min.
0.65N {66 gf}
0.05N {5 gf}
㸦1.15㸧
Overtravel
Movement Differential MD Max.
OT
1.9 mm (reference value)
0.5 mm
FP
OP
TTP
Free Position
Operating Position
Total Travel Position
FP Max. 16.5 mm
12.5 mm
11.2 0.5 mm
9.5 mm
㸦0.4㸧
7
OP
15.2 0.5mm
TTP Max. 13.5 mm
●Hinge Roller Lever
D2HW-@24@@
M3-screw
Mounting
Models
Operating
characteristics
Models with
Posts
4.8×2.8 dia.
Polyacetal resin roller
Type
A
0.1
8
㸦4.6㸧
Operating Force
Releasing Force
Overtravel
OF Max.
RF Min.
0.65N {66 gf}
0.03N {3 gf}
15
t0.3
Stainless-steel
lever
OT
1.9 mm (reference value)
0.6 mm
FP
OP
Movement Differential MD Max.
㸦1.15㸧
TTP
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP Max.
15.3 mm
14 0.6 mm
12.3 mm
3
㸦0.4㸧
6.5
Note1. Unless otherwise specified, a tolerance of 0.2mm applies to all dimensions.
Note2. The operating characteristics are for operation in the A direction ( ).
5
D2HW
Sealed Ultra Subminiature Basic Switch
●Leaf Lever
D2HW-@26@@
2.65
M3-screw
Mounting
Models
Operating
characteristics
Models with
Posts
0.1
8
Type
A
3.4
t0.3 Stainless-steel lever
14
Operating Force
Releasing Force
OF Max.
RF Min.
1.8N {183 gf}
0.20N {20 gf}
㸦1.7㸧
FP
OP
TTP
Overtravel
Movement Differential MD Max.
OT
1.8 mm (reference value)
0.5 mm
3
6.5
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP Max.
9.3 mm
7.4 0.5 mm
5.8 mm
D
2
H
W
●Simulated Roller Lever
D2HW-@27@@
M3-screw
Models with
Mounting
A
3.4
Operating
characteristics
R2
Type
t0.3 Stainless-steel lever
16
Posts
Models
2.65
0.1
8
Operating Force
Releasing Force
OF Max.
RF Min.
1.8N {183 gf}
0.20N {20 gf}
㸦1.7㸧
FP
OP
TTP
Overtravel
Movement Differential MD Max.
OT
2.0 mm (reference value)
0.5 mm
3
6.5
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP Max.
13.0 mm
10.8 0.5 mm
8.9 mm
●Long Leaf Lever
D2HW-@28@@
A
1
20.85
t0.2 Stainless-steel lever
M3-screw
Models with
Mounting
Operating
characteristics
Type
18.5
2.65
Posts
Models
0.1
13
FP
Operating Force
Releasing Force
OF Max.
RF Min.
0.9N {92 gf}
0.05N {5 gf}
OP
TTP
0.15
3.3
3.1
dia.
6
Overtravel
Movement Differential MD Max.
OT
2.8 mm (reference value)
0.7 mm
3
+0.13
-0.03
Free Position
Operating Position
Total Travel Position
FP Max.
OP
TTP Max.
19 mm
15.4 1.5 mm
12.8 mm
㸦12㸧
3-00.1dia.
*
COM AVSS 0.5 (Black)
NO AVSS 0.5 (Blue)
NC AVSS 0.5 (Red)
10
300
㸦5㸧
1.5-00.1
5.3
1.5-00.1
㸦13.3㸧
UL approved wires (AWG24, UL1007) are used for UL/CSA
standard approved items.
*
Note1. Unless otherwise specified, a tolerance of 0.2mm applies to all dimensions.
Note2. The operating characteristics are for operation in the A direction ( ).
6
D2HW
Sealed Ultra Subminiature Basic Switch
Precautions
★Please refer to "General Information" for correct use.
Cautions
Correct Use
●Degree of Protection
●Mounting
• Do not use this product underwater.
• Turn OFF the power supply before mounting or removing the
Switch, wiring, or performing maintenance or inspection.
Failure to do so may result in electric shock or burning.
• For M3-screw mounting models, use M3 mounting screws with
plane washers or spring washers to securely mount the
Switch.
Although molded lead wire models satisfy the test conditions
for the standard given below, this test is to check the ingress of
water into the switch enclosure after submerging the Switch in
water for a given time. Satisfying this test condition does not
mean that the Switch can be used underwater.
JIS C0920:
D
2
H
W
Tighten the screws to a torque of 0.27 to 0.29 N·m {27.5 to
29.5 gf}. Exceeding the specified torque may result in
deterioration of the sealing or damage.
Degrees of protection provided by enclosures of electrical
apparatus (IP Code)
IEC 60529:
• For models with posts, secure the posts by thermal caulking or
by pressing into an attached device. When pressed into an
attached device, provide guides on the opposite ends of the
posts to ensure that they do not fall out or rattle.
Thermal caulking conditions varies according to the equipment,
jig and base used for switch mounting. Consult your OMRON
sales representative for details.
Degrees of protection provided by enclosures (IP Code)
Degree of protection: IP67
(check water intrusion after immersion
for 30 min. submerged 1m underwater)
• Do not operate the Switch when it is exposed to water spray,
or when water drops adhere to the Switch surface, or during
sudden temperature changes, otherwise water may intrude
into the interior of the Switch due to a suction effect.
• Prevent the Switch from coming into contact with oil and
chemicals.
●Operating Body
• Use an operating body with low frictional resistance and of a
shape that will not interfere with the sealing rubber, otherwise
the plunger may be damaged or the sealing may deteriorate.
Otherwise, damage to or deterioration of Switch materials may
result.
●Handling
• Do not use the Switch in areas where it is exposed to silicon
adhesives, oil, or grease. Otherwise faulty contact may result
due to the generation of silicon oxide.
• Do not handle the Switch in a way that may cause damage to
the sealing rubber.
• When handling the Switch, ensure that pressure is not applied
to the posts in the directions shown in the following diagram.
Also, ensure that uneven pressure or pressure in a direction
other than the operating direction is not applied to the Actuator
as shown in the following diagram. Otherwise, the post,
Actuator, or Switch may be damaged, or the service life may
be reduced.
●Soldering
When soldering the lead wire to the terminal, first insert the
lead wire conductor through the terminal hole and then
conduct soldering.
Make sure that the temperature of the soldering iron tip does
not exceed 300°C, and complete the soldering within 3
seconds. Do not apply any external force for 1 minute after
soldering.
Soldering at an excessively high temperature or soldering for
more than 3 seconds may deteriorate the characteristics of the
Switch.
In case of automatic soldering, please do not apply the heat
beyond 260°C within 5 seconds. Pay careful attention so that
flux or solder liquid does not flow over the edge of the PCB
panel.
●Wiring Molded Lead Wire Models
• When wiring molded lead wire models, ensure that there is no
weight applied on the wire or that there are no sharp bends
near the parts where the wire is drawn out.
Otherwise, damage to the Switch or deterioration in the
sealing may result.
●Side-actuated (Cam/Dog) Operation
• When using a cam or dog to operate the Switch, factors such
as the operating speed, operating frequency, push-button
indentation, and material and shape of the cam or dog will
affect the durability of the Switch. Confirm performance
specifications under actual operating conditions before using
the Switch in applications.
●Using Micro Loads
• Even when using micro load models within the operating
range shown below, if inrush/surge current occurs, it may
increase the contact wear and so decrease durability.
Therefore, insert a contact protection circuit where necessary.
7
D2HW
Sealed Ultra Subminiature Basic Switch
D
2
H
W
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. B105-E1-06
0812(0207)(O)
8
相关型号: