CVM1-MP702-V1 [OMRON]

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control; 多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制
CVM1-MP702-V1
型号: CVM1-MP702-V1
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Multi-application Controllers: From High-performance Machine C ontrol to Highly Reliable Process Control
多应用控制器:从高性能计算机C ONTROL高度可靠的过程控制

控制器 计算机
文件: 总70页 (文件大小:8647K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Programmable Controllers  
Multi-application Controllers:  
Concepts .................................. F-2  
System Design Guide...................1  
System Configuration .................................2  
Dimensions/Mounting Dimensions .............9  
General Specifications..............................11  
Common Specifications for CPU Units.....12  
From High-performance Machine C ontrol to  
Highly Reliable Process Control  
Current Consumption for Power  
Supply Units .............................................15  
Ordering Information...................17  
Basic Configuration Units .........................18  
Programming Devices ..............................22  
Optional Products and Maintenance  
Products ...................................................25  
DIN Track Accessories.............................25  
Basic I/O Units..........................................26  
Special I/O Units and CPU Bus Units.......32  
Replacing C200H I/O Units ......................54  
Ultimate Controller Performance  
User-friendly Development Environment  
Efficient Use of Valuable Assets  
In order to create facilities that have the production  
capability to withstand sudden changes in demand, or to  
create machinery that is easily distinguished from that  
created by market competitors, a top-speed controller that  
can deliver the performance required to support these  
needs is required. The SYSMAC CS1 PLCs have been  
equipped with the highest I/O responsiveness and data  
control functionality to significantly reduce processing time  
and to control machinery movement with greater precision.  
In order to allow easier development of complex  
programs, bin addition to an integrated Windows-based  
development environment, the new PLCs are equipped  
with a variety of instructions. Structured programming  
functionality has been improved to allow programs to be  
reused with greater efficiency and thereby reduce labor  
requirements and cut costs.  
The know-how that our customers have  
accumulated through the years forms the core of  
their competitive strength. At OMRON, we believe in  
enhancing this knowhow to the utmost. The key to  
doing this is 100% upward compatibility. CS1 PLCs  
allow existing Units and programs to be used without  
any changes.  
2
F-2  
F-3  
Use the improved SYSMAC CS1 PLCs to  
scale advanced systems to the optimum size.  
Control Up to 960 Points with  
Units Mounted to the CPU Rack  
Wide Lineup Makes It Easy to Build the Optimum System  
Improved Refresh Performance for Data Links,  
Remote I/O Communications, and Protocol Macros  
A total of nine CPU Unit models provide for  
a wide range of applications, from  
Communications Boards, and a wide  
selection of Special I/O Units that can be  
used with any CPU Units to flexibly build the  
system that meets the requirements.  
The CS1 provides a high level of space  
efficiency. As many as 960 I/O points can  
be controlled by simply mounting ten Basic  
I/O Units, with 96 I/O points each, to the  
CPU Rack. Alternatively, as many as 80  
analog I/O points can be used by mounting  
five Analog Input Units and five Analog  
Output Units.  
In the past, I/O refresh processing with the  
CPU Unit  
small-scale systems to large. The lineup  
also includes Memory Cards, Serial  
CPU Bus Unit only occurred during I/O  
Immediate  
I/O refresh  
CPU Bus  
Unit n  
1
DLNK  
refresh after instructions were executed.  
n
With the new CS1, however, I/O can be  
CIO Area words  
Product lineup (Example: LD instruction processing speed, DM capacity)  
refreshed immediately by using the DLNK  
allocated to CPU  
Bus Units  
instruction. Immediate refreshing for  
Program  
Capacity  
DM Area words  
allocated for CPU  
processes peculiar to the CPU Bus Unit,  
Data exchange  
during  
communications  
cycle  
Bus Units  
250 K  
steps  
such as for data links and DeviceNet remote  
Specific Area for  
CPU Bus Units  
I/O communications, and for allocated CIO  
(LD: 0.02 µs, DM: 448 Kwords)  
Area/DM Area words when instructions are  
executed, means greater refresh  
120 K  
steps  
responsiveness for CPU Bus Units.  
Unit name  
Refresh function  
Ten I/O Units of 96 points each  
(LD: 0.02 µs, DM: 256 Kwords)  
Controller Link Unit  
Data links  
(LD: 0.02 µs, DM: 128 Kwords)  
60 K  
DeviceNet Unit  
Remote I/O  
steps  
Serial Communications  
Unit  
Protocol macros  
(LD: 0.04 µs, DM: 128 Kwords)  
(LD: 0.02 µs, DM: 64 Kwords)  
Socket service based  
on manipulation of  
specific bits.  
Ethernet Unit  
30 K  
steps  
Five Analog Output Five Analog Input Units  
Units of 8 points each of 8 points each  
(LD: 0.04 µs, DM: 64 Kwords)  
Reduced Variation in Cycle Time During Data Processing  
20 K  
steps  
Large Capacity CPU Units for  
Greater Component Control Power  
Instructions that require long execution time,  
such as table data processing instructions  
and text string processing instructions, are  
processed over multiple cycles to minimize  
variations in cycle time and maintain stable  
I/O response.  
(LD: 0.04 µs, DM: 64 Kwords)  
(LD: 0.02 µs, DM: 64 Kwords)  
The CS1 CPU Units boast amazing capacity  
with up to 5,120 I/O points, 250 Ksteps of  
programming, 448 Kwords of data memory  
(including expanded data memory) and  
4,096 timers/counters each. With a large  
programming capacity, CS1 PLCs are not  
only ideal for large-scale systems but easily  
handle value-added applications and other  
advanced data processing.  
10 K  
steps  
(LD: 0.04 µs, DM: 64 Kwords)  
960 pts  
Only start of  
Table data/  
Long  
Table data/  
text string  
processing  
text string  
processing  
processing  
designated.  
execution  
time  
1,280 pts  
5,120 pts  
Number of  
I/O points  
Two Series of Expansion Racks Up to 50 m Long for  
The cycle is  
Long-distance Expansion with Up to 72 Units and 7 Racks  
temporarily extended  
when the instruction  
is executed.  
Background processing performed over  
several cycles to limit the impact on cycle  
time and thus reduce variation in cycle time.  
With an expansion capacity  
of up to 80 Units and 7  
I/O Control Unit  
CPU  
System Bus Baud Rate Doubled  
The data transfer rate between the CPU  
Unit and certain Units has been doubled to  
further improve total system performance.  
Variation  
Racks over a distance of  
12 meters, the CS1 can  
meet large-scale control  
needs. Alternatively, an I/O  
Control Unit and I/O  
2 Series of  
Expansion Racks;  
Up to 7 Racks Total  
Faster Instruction Execution and Faster Overall Performance  
9 Units  
I/O Interface Unit  
Baud rate  
Interface Units can be used  
to connect two series of CS1  
Longdistance Expansion  
Racks extending up to 50  
m each and containing a  
total of up to 72 Units and 7  
Racks. CS1 Basic I/O Units,  
CS1 Special I/O Units, and  
CS1 CPU Bus Units can be  
mounted anywhere on the  
Racks and programmed  
without being concerned  
about special remote  
In addition to further improvements to the  
instruction execution engine, which is the  
core of overall PLC performance, the  
high-speed RISC chip has been upgraded to  
realize the fastest instruction execution  
performance in the industry. Also, the new  
doubled  
models have a mode where instruction  
execution and peripheral processing are  
processed in parallel, enabling balanced  
improvements in overall speed.  
System bus  
50 m  
50 m  
Special I/O Unit  
CPU Unit  
Common Processing  
0.3 ms  
16  
PCMIX Value  
Cycle Time (  
Basic instructions only: 38 Ksteps/ms  
Including special instructions: 22 Ksteps/ms  
Cycle time for 128 inputs  
and 128 outputs  
)
Terminating Resistor  
programming requirements.  
Note: C200H Units cannot be  
mounted on the Longdistance  
Expansion Racks.  
LD Instruction Processing Speed  
OUT Instruction Processing Speed  
Subroutine Processing Speed  
20 ns  
20 ns  
2.1 µs  
F-4  
F-5  
Equipped with functions demanded by  
the production site to suit a variety of applications.  
Nested Interlocks (for CPU Unit Ver. 2.0 or Later)  
Simpler Ladder Programs  
Ladder programs that use a lot of basic  
instructions can be simplified using  
differentiation instructions LD NOT, AND  
NOT, and OR NOT, and instructions that  
access bits in the DM and EM Areas.  
Convert Between Floating-point Decimal and Character Strings  
The new CS1 can convert floating-point  
decimal (real numbers) to character strings  
(ASCII) for display on a PT (operator  
The new CS1 can convert ASCII character  
strings read from measurement devices by  
serial communications to floating-point  
decimal data for use in data processing.  
Although strictly speaking the present  
interlock instructions do not allow nesting,  
applications can be created to include  
combination of complete and partial interlock  
conditions that achieve nested interlocks.  
Emergency  
stop button  
MILH 0  
MILH 1  
2
Conveyor  
operates  
interface). The data can be displayed on the  
PT as a character string display element.  
Worker  
present (a)  
PT  
Measurement device  
With other PLCs  
With CS1-series PLCs  
Conversion  
instruction  
(example)  
Conversion  
Operator  
Product  
added  
instruction  
a
Floatingpoint  
decimal  
Character  
string  
500.00  
Character  
string  
Floatingpoint  
decima  
Product added  
by contact a  
Contact a  
Emergency  
stop button  
MILC 1  
MILC 0  
Serial  
communications  
a
E.g., 500.00  
353030E23030  
Character-string  
display element  
CX-Programmer Screen  
Support Software  
Highly Accurate Positioning  
with XY Tables  
The new CS1 has many doubleprecision  
processing instructions for floating-point  
decimal operations, enabling positioning  
with greater accuracy.  
PID Autotuning  
clearly shows the  
interlock status.  
OUTB  
a
The new CS1 can autotune PID constants  
with a PID control instruction. The limit cycle  
method is used for autotuning, so the tuning  
is completed quickly. This is particularly  
effective for multiple-loop PID control.  
ORW  
D00000  
#0001  
D00000  
a
(1) Conveyor operates  
(2) Contact "a" turns ON when operator is present and products  
are supplied.  
(3) When the emergency stop button is pressed, the conveyor  
and product addition both stop.  
D00000  
#0000  
ANDW  
D00000  
#FFFE  
D00000  
Easy Cam Switch Control with Ladder Instructions (for CPU Unit Ver. 2.0 or Later)  
Autotuning for PID constants  
(limit cycle method)  
Angular data  
Comparison table  
Output  
PIDAT  
Upper limit Lower limit  
ON  
OFF  
OFF  
Value  
Cam switch  
Absolute  
converted  
by GRY  
instruction  
PID control instruction with  
autotuning  
Binary Set Values for  
Timer/Counter Instructions  
ON  
OFF  
encoder  
Floating-point  
The SV for a timer or counter instruction can  
be specified using either BCD or binary.  
Using binary SV enables longer timers and  
higher-value counters.  
Compared using  
BCMP2 instruction  
decimal instruction  
* The time  
interval for  
High-precision positioning  
Error Status Generation for  
Debugging  
execution by the  
GRY instruction  
is determined by  
the response  
speed for reading  
data from the  
GRY  
BCMP2  
Parallel  
wiring  
+
Gray code converted  
into binary, BCD, or  
angles.  
Compared to see whether  
data is between upper  
and lower limits.  
A specified error status can be simulated by  
executing the diagnostic instructions  
(FAL/FALS). With the new CS1, debugging  
is simple for applications that display  
messages on a PT or other display device  
based on the error status of the CPU Unit.  
Easy Reading of Maintenance  
Data via Componet/DeviceNet  
The addition of special explicit message  
instructions makes it easy to send explicit  
messages without having to consider FINS  
commands. Transferring data among PLCs  
with explicit messages is also simplified.  
Examples: Timer/Counter Instructions  
TIM (BCD): 0 to 999.0 s  
absolute encoder.  
TIMX (550) (binary) 0 to 6553.5 s  
CNT (BCD): 0 to 999 counts  
Easy Calendar Timer Function  
(for CPU Unit Ver. 2.0 or Later)  
TIME-PROPORTIONAL OUTPUT  
(TPO) Instruction  
(for CPU Unit Ver. 2.0 or Later)  
CNTX (546) (binary) 0 to 65,535 counts  
[Applicable Instructions]  
PT  
(Example)  
Timer/Counter Instructions  
An error has  
occurred at unit  
number xx.  
• TIMER: TIMX (550)  
=
DT  
• COUNTER: CNTX (546)  
Special explicit  
• HIGH-SPEED TIMER: TIMHX (551)  
• ONE-MS TIMER: TMHHX (552)  
• ACCUMULATIVE TIMER: TTIMX (555)  
• LONG TIMER: TIMLX (553)  
message instruction  
No need to  
consider FINS  
Error in Special I/O Unit  
PID  
Compares two dates/times  
Comparison can be limited  
to any combination of  
years, months, days, hours,  
minutes, or seconds.  
S
C
D
SSR  
DeviceNet  
CompoNet  
FAL  
• MULTI-OUTPUT TIMER: MTIMX (554)  
• REVERSIBLE COUNTER: CNTRX (548)  
• RESET TIMER/COUNTER: CNRX (547)  
Example:  
A calendar timer function  
can be easily set up to start  
a process at exactly 5:00  
every evening.  
TPO  
S
PT  
There is a  
C
possibility that  
rack number xx  
is disconnected.  
Turn ON at 5:00  
every evening  
B
20% 80%  
Time-proportioning PID control  
can be handled by the PLC by  
combining the PID and TPO  
(TIME-PROPORTIONAL  
OUTPUT) instructions.  
I/O bus error  
1 s  
FALS  
(Supported for DeviceNet Unit version 2.0 or later.)  
F-6  
F-7  
The CX-One FA Integrated Tool Package makes design,  
development, and maintenance easy and efficient.  
Improved Programming Efficiency with Single-key Operation  
Multiple Languages Can Be Combined  
To Make Programming Flexible  
The CX-Programmer features the “Single-key Concept” to increase operability. Apart from inputs to  
ladder diagrams, history searches, and model jumps, single-key operation can be used for  
simulation debugging as well.  
The multilingual feature supports IEC  
61131-3. Programming is possible in a  
language that is appropriate for the process  
by combining ladder diagram and ST  
languages. Function blocks can be created  
to make programming even more efficient.  
Single-key Inputs  
The allocation of shortcut keys can be checked in the  
guidance for ladder input key operations. Key inputs,  
Integrated OMRON PLCs and Component Support Software  
such as the  
Key for OUTPUT instruction, and the  
special instructions are convenient when programming.  
Key for NO input conditions, the  
Key for  
FA Integrated Tool Package  
Ladder diagram:  
Controls the  
User program  
equipment and  
Just press the  
Key and enter the bit number and  
3
external devices.  
comment to complete the input condition. Special  
instruction can be input as shown in the following figure.  
Function Block  
(FB): Can be  
CX-One Configuration  
FB  
Task  
The CX-One is an FA Integrated  
used and reused  
as modules.  
CX-Integrator CX-FLnet CX-Protocol  
CX-Configurator FDT Network Configurator  
a
:
a + 1;  
=
1
Network Software  
RESULTS=0.0;  
IF M=TRUE THEN  
RESULTS=SIN (date):  
ENDIF;  
Tool Package for connecting,  
setting, and programming OMRON  
components, including PLCs. CS1  
programming and settings can be  
done with just the CX-Programmer,  
but the CX-One provides Support  
Software for setting and  
Structured Text (ST):  
Simplifies math  
calculations and  
character string  
processing.  
Task  
Task  
Task  
Lines can be easily connected using key operations.  
CX-Programmer  
CX-Simulator  
SwitchBox Utility  
PLC Software  
HMI Software  
2
3
Ctrl  
Sequential Function  
Charts (SFC):  
Controls the steps  
in processing.  
CX-Designer  
The Ladder Monitor Software is included. (See note 1.)  
Single-key Simulation  
Single-key Searches and Jumps  
NV-Designer (See note 2.)  
A programming language suitable for the  
process can be used.  
Simulation and debugging of a PLC program can  
also be executed with a single key. Applications  
using both a PLC and Programmable Terminal can  
be debugged using a computer without the actual  
devices using PLC-PT Integrated Simulation.  
Search functions, such as Find Back (searching  
for input conditions or outputs with the same  
address) and Find Address can be executed with  
a single key.  
CX-Drive  
CX-Motion-NCF CX-Motion-MCH  
CX-Position  
Motion Control  
Software  
4
OMRON FB Library, SAP  
programming PTs, Temperature  
Controllers, and many other  
CX-Motion  
Ladder diagrams, communications programs, and control screens can  
be created simply by selecting and pasting program modules from the  
extensive libraries. Using FB and SAP modules to build the programs,  
it is possible to create programs that are easier to understand.  
PLC-based Process  
Control Software  
CX-Process Tool  
Face Plate Auto-Builder for NS  
5
6
components. Using the CX-One  
makes programming and setup  
easy, shortening the total lead time  
required for starting up machines  
and equipment.  
Component Software for  
Temperature Controllers  
CX-Thermo  
Icons for the simulation function can be accessed directly.  
Note: 1. The Ladder Monitor is required to monitor ladder programs running on  
CS/CJ-series PLCs from an NS-series PT.  
2. Include with CX-One Lite version 4.0 and in CX-One version 3.2 or later.  
Debugging  
Batch Backup  
Ladder diagram Monitoring for  
Multiple PLCs  
Multiple PLCs can be monitored by  
displaying them in series on the screen.  
This way it is easy to debug data links  
between PLCs and monitor the inputs and  
outputs of different PLCs.  
Batch Backup/Restore with a  
Computer  
Management of Multiple Networks  
The operation of networks with configurations  
consisting of multiple networks including PLC  
networks such as EtherNet/IP and Controller  
Link, field networks such as DeviceNet and  
CompoNet, and networks for Programmable  
Terminals and Serial Devices, can be restored  
simultaneously from the CX-One. Onsite start  
up and debugging can be conducted efficiently  
and without errors because PLCs and devices  
can be selected from the window to transfer  
programs and parameter data to the computer  
during operation.  
A computer can be used to backup,  
compare, or restore data for all or specific  
PLC Units when connected online. Backup  
information is automatically tagged with a  
date stamp. It is thus possible to return to  
the state before an error occurred. It is also  
easy to identify the file  
Easy Programming  
Smart Input  
A complete range of intuitive programming functions is provided, including instruction and address  
input assistance, address incrementing, and address Incremental Copy.  
These functions enable waste-free programming with minimal effort.  
PLC1  
PLC2  
PLC3  
for restoring data when  
Node 1  
Node 2  
Node 3  
Instruction and Address Input Assistance  
an error occurs.  
When you begin typing an instruction from the keyboard while in the Ladder Editor Window, suggested  
Specified backup  
destination folder  
instructions are displayed.  
All you have to do is select the instruction from the list for easy input even if you do not remember the entire  
mnemonic.  
PLC Backup  
Software  
SYSMAC CS/CJ-series PLC  
(CPU Unit + Configuration Units)  
Suggested instructions  
displayed  
Restore  
Compare  
CX-Programmer  
CX-Integrator  
Backup  
Time Require for Debugging and Maintenance Has Been Reduced with  
the Comprehensive Data Trace Function  
Data Trace Function  
Functionality and operability has been  
Sampled values from a specific word will be displayed.  
significantly upgraded compared to the  
Automatic Insertion of Connecting Lines  
previous data trace function. The new data  
trace function provides comprehensive  
debugging, such as I/O comment display of  
sampled addresses, specification using  
symbols, checking the measurement time  
between two selected points, and layering  
waveforms. Furthermore, data sampled  
When an output or application instruction is input, the required connecting line is inserted automatically  
starting at the cursor location. This greatly simplifies the work required to insert lines.  
Address Incremental Copy  
To create the same group of ladder instructions more than once, the address incremental copy function can  
be used to reuse the instructions simply by inputting an address offset. Also, address offsets can be set  
individually and I/O comments can be created automatically.  
from the CPU Unit’s trace memory can be  
Sampled value from a  
The traced waveforms can be  
saved to a file on the computer at a  
specified frequency. This can be used as for  
specific input bit will be  
displayed as layers.  
displayed.  
long-term logging of data.  
F-8  
F-9  
Further improvements to communications functions.  
Seamless networks increase production site transparency.  
A Wide Range of Systems,  
from Small-scale to Large  
High-speed, High-capacity Data  
Links between PLCs via  
Functions for Better Ethernet  
Support  
The Solution for Communicating across Network Levels  
Ethernet is becoming increasingly important  
standard for information networks. Up to  
eight socket interfaces for TCP/IP and  
UDP/IP are supported, in addition to FINS  
messages, FTP file transfers, and mail  
notification, so that production management  
can now be organically linked with the  
production site.  
OMRON offers a full lineup of reliable PLCs  
including the "flagship" CS1 Series, and ranging  
from the small scale CP1H to the large-scale  
CV Series. The CS1 Series meets the needs  
not only of small-scale to large-scale systems,  
but of distributed systems as well. This allows  
the construction of the optimum system for the  
scale and applications of the production site.  
EtherNet/IP  
seamless communications system for  
The SYSMAC CS1 enables FINS message  
communications across a maximum of eight  
levels (See note.) (using CX-Programmer  
Ver. 4.0 or higher) in comparison with three  
levels in previous OMRON systems  
EtherNet/IP is supported. EtherNet/IP is a  
global-standard network that uses  
cutting-edge general Ethernet technology  
for control and information network  
integration. This enables data links between  
PLCs, data links between a PLC and  
multi-vendor devices, and communications  
between PLCs and PTs over a general  
Ethernet network.  
sending FINS messages across multiple  
levels of Ethernet and Controller Link  
networks.  
4
Note: For CPU Unit Ver. 2.0 or later.  
Expansion up to eight levels lets you build a  
Head office or  
remote office  
Head office, remote office,  
home, business trip destination  
• CX-Programmer  
CompoNet Greatly Advances  
Wiring Reductions, Greater  
Information Handling, and  
• Web browser  
• CX-Programmer  
FA Wireless LAN Unit  
WE70  
Standardization  
CompoNet is a multi-vendor network for  
bit-level control of approximately 1,000  
points in 1.0 ms. It supports message  
communications at the sensor and actuator  
levels. Maintenance information can be  
controlled in each Slave for preventative  
maintenance of equipment.  
Ethernet and EtherNet/IP  
CS1  
CS1  
Ethernet Unit and  
EtherNet/IP Unit  
Ethernet Unit and  
EtherNet/IP Unit  
Controller Link Unit  
Flexible System Building Based  
on the DeviceNet  
The CS1 Series supports the worldwide  
multivendor bus standard, DeviceNet.  
Component connections in a multivendor  
environment are greatly enhanced by  
connecting to up to 64 nodes for a wide  
range of FA applications, and by device  
profiles and configurator tools that ensure  
high reliability and easy maintenance.  
Production systems can be configured even  
more flexibly by incorporating products such  
as the MULTIPLE I/O TERMINAL.  
Controller Link  
Hub  
EtherNet/IP  
NS Series V8  
CS1  
CS1  
CS1  
CS1  
CompoNet  
Master Unit  
EtherNet/IP Unit  
DeviceNet Unit  
EtherNet/IP Unit  
CompoNet  
Master Unit  
Controller  
Link Unit  
DeviceNet Unit  
Controller Link Unit  
CompoNet  
DeviceNet  
CompoNet  
DeviceNet  
GRT1-TBL  
ID4  
ID4  
ID4  
OD4  
OD4  
OD4  
END  
GRT1-TBL  
ID4  
ID4  
ID4  
OD4  
OD4  
OD4  
END  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
TS  
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
0
2
1
3
F-10  
F-11  
Construction of systems in multi-vendor environments simplified  
with Serial Gateway Function.  
(CPU Unit Ver. 3.0 or later)  
Serial Communications Configuration Example  
Serial Gateway (Serial Communications Units/Boards with Ver. 1.2 or later)  
Enhanced Protocol Macro  
Programming Devices  
CX-Programmer  
CX-Protocol  
CX-Motion  
Functionality  
(Serial Communications Units/Boards with Ver. 1.2 or later)  
Truly Seamless Incorporation of OMRON Components and Other Devices  
into Networks  
Programming  
Console  
Host computer, etc.  
When the CPU Unit (Ver. 3.0 or later) or  
5
Baud rate increased from 38,400 bps to  
57,600 bps for faster communications.  
Standard system protocol added for  
greater connectability with components  
and PLCs.  
Serial Communications Board or Serial  
FINS network  
Communications Unit (Ver. 1.2 or later)  
Host Link  
Serial Communications Board  
CPU Unit  
Gateway  
ASCII Unit  
Serial Communications Unit  
receive a FINS command containing a  
CompoWay/F command (see note 1.) via  
Peripheral bus  
(Programming  
Console bus)  
Programmable  
Terminal  
Serial  
Component/PLC  
network or serial communications, the  
communications  
CompoWay/F Master  
command is automatically converted to a  
Host Link Master functions  
Mitsubishi Computer Link Master  
protocol suitable for the message and  
Note 1: FINS  
Abbreviation for Factory Interface Network Service. A  
command system for message services common to  
OMRON networks. FINS commands can be sent across up  
to 8 network levels*, including serial communications paths  
using a serial gateway. (*Possible only with CS/CJ-series  
CPU Unit Ver. 2.0 or later.)  
forwarded using serial communications.  
CompoWay/F (See note 2.)  
Wide Range of Applicable  
Protocols Allows for High  
Value-added Programs  
(Possible only with Serial  
Communications Units or Serial  
Communications Boards)  
Host Link FINS  
NT Link  
Note 2: CompoWay/F  
CompoWay/F is an integrated communications protocol  
used for OMRON general-purpose serial communications.  
It is used by Temperature Controllers, Digital Panel Meters,  
Timer/Counters, Smart Sensors, Cam Positioners, Safety  
Controllers, etc. (as of July 2004).  
Protocol macros  
The CS1 Series supports a wide range of  
serial communications protocols, such as  
Host Link, no-protocol, NT Link, peripheral  
bus, and more. These allow for high  
value-added programs such as MMI,  
communications, and data processing.  
Commercially-available  
external device  
Commercially-available Microcomputer,  
external device  
Non-OMRON  
PLCs, etc.  
etc.  
Serial Gateway System (Reference)  
When CompoWay/F commands are enclosed  
in FINS commands and sent to Serial  
Communications Boards or Serial  
General-purpose protocol  
using BASIC in ASCII Unit  
Temperature controller,  
bar code reader, etc.  
FINS command received  
Protocol macros  
Serial Gateway: FINS  
command "capsule"  
opened and contents  
retrieved.  
Sent as a CompoWay/  
F command  
Protocol macros  
The Fastest Communications in the  
Industry with High-speed NT Links  
Communications Units (Ver. 1.2) or serial  
ports on CPU Unit Ver. 3.0, the enclosed  
CompoWay/F command is retrieved using a  
Serial Gateway Function and sent as a  
CompoWay/F command.  
Combine with one of the NS Series  
Programmable Terminals (NS12, NS10, or  
NS7) to enable connecting Highspeed NT  
Links. Using NT Link terminology together  
with a communications speed of 115 Kbps  
provides high-speed response.  
No-protocol  
Host Links  
Sending Host Link and  
FINS commands  
Temperature  
Controller  
Smart Sensor  
CPU Unit  
RS-232C Port  
Reading and writing  
of I/O memory and  
operating modes  
OMRON Components  
Serial  
Serial  
Communications  
Board  
Communications  
Unit  
NT Links (1:N Mode)  
More Ports for Even More  
Serial Device Connections  
Windows-based Software Simplifies  
Serial Device Connections  
TXD instruction  
or RXD instruction  
using Serial  
Communications  
Unit  
TXD instruction or  
RXD instruction  
using CPU Unit's  
RS-232 port or Serial  
Communications Board  
Device  
Protocol macros make it easy to create serial  
communications protocols (communications  
frames, error checks, retries, error  
Protocol macros for Serial Communications  
Units and Boards can be created using the  
CX-Protocol, thus enabling message tracing  
and greatly reducing the time involved in  
connecting various serial devices.  
Response  
Data input from a  
bar code reader  
Data output to printer  
processing, etc.) to match those of remote  
communications devices. Multiple ports are  
provided for this function. Each PLC  
supports up to 16 Serial Communications  
Units (32 ports total) and one Serial  
Communications Board (with 2 ports). This  
makes it possible to connect up to 34  
devices with serial communications at a  
speed of 38.4 Kbps. Message length has  
been increased from 256 to 1,000 bytes to  
give communications more power than ever  
before.  
Supports No-protocol Communications  
(Serial Communications Units/Boards with Ver. 1.2 or later)  
Programmable  
Terminal  
Programmable  
Terminal  
No-protocol communications supported for Serial  
Communications Units and Serial Communications  
Boards.  
This mode enables components to be connected to  
multiple communications ports using no-protocol  
communications.  
Serial port I/O instructions executable using no-protocol  
communications from Serial Communications Units and  
Serial Communications Boards (TXDU, RXDU, TXD,  
and RXD) are supported for CPU Units with Ver. 3.0 or  
later.  
* PLC-to-PT connection in NT Link (1:N mode)  
communications can be either one-to-one or one-to-many.  
F-12  
F-13  
Advanced management and resource inheritance  
providing powerful support for maintenance and operation.  
Remote Maintenance  
Boost Program Security by  
Prevent Information Leaks from  
Write Protection from a Specific  
Keeping Part of It Hidden  
(for CPU Unit Ver. 2.0 or Later)  
PLCs (for CPU Unit Ver. 2.0 or Later)  
In addition to applying read protection  
functions to the user program area and  
tasks, you can also protect against the  
transfer of user programs to a Memory Card.  
This prevents leaks of proprietary  
Node over the Network  
(for CPU Unit Ver. 2.0 or Later)  
1. Program or monitor a remote  
PLC via a modem connection.  
2. Program or monitor a  
network PLC via a Host Link  
connection.  
You can prevent access to special tasks by  
You can now stop specific nodes from  
writing over the network. By preventing  
unintentionally writes to the PLC while  
monitoring data over the network, you  
can prevent potential problems.  
6
requiring the user to have a password to  
read them.  
Task 1  
3. Send e-mail for errors from  
PLCs connected to Ethernet.  
3. Mail  
information by completely protecting against  
the reading of programs inside the PLC.  
Ethernet  
{
Use a password to  
prevent reading of  
only task 2.  
CX-Programmer  
Ver. 4.0  
Task 2  
Read  
×
protection  
Host Link  
Modem  
Reading  
possible  
Reading  
CX-Programmer  
Ver. 4.0  
{
Task 3  
possible  
Write  
1. Remote programming/monitoring  
via modem (See note.)  
×
protection  
No transfer  
possible  
Write enabled  
Phone line  
This allows you to hide crucial parts of the  
program.  
2. Remote  
Memory Card  
programming/  
monitoring via  
Host Link (See note.)  
By applying write protection, you can also  
prevent a user from inadvertently writing over  
the hidden part of the program. This provides  
additional protection for your program.  
Modem  
Easy Replacement of Existing  
Replace Malfunctioning Units  
without Turning OFF the Power  
(Online Unit Replacement)  
Note: The same kind of programming and monitoring  
performed via normal Host Link is possible.  
Models  
Read protection  
Programs designed for existing models  
(C200HX/HG/HE, CVM1, or CV-series  
PLCs) using the CX-Programmer can be  
converted for use with the new CS1. The  
following functions are available to make the  
×
When an I/O Unit, a Special I/O Unit, or a  
CPU Bus Unit is malfunctioning, it is now  
possible to replace the faulty Unit while the  
system continues operating. This is  
Memory Cards for Data File  
Management  
×
Office  
Write protection  
conversion to the new CS1 even easier.  
CV-CS address conversion instruction to  
convert programs designed for the  
CVM1/CV that include internal I/O memory  
addresses.  
User programs, I/O memory, or system  
parameters can be converted to  
particularly effective for systems that cannot  
be stopped when a problem has occurred in  
another part of the system.  
Internal Flash Memory-based  
Battery-free Operation  
Windows-based files and stored in Memory  
Cards or in EM file memory in the CPU Unit.  
It is also possible to automatically read the  
user program and other data from the  
Memory Card to the CPU Unit at startup,  
replacing ROM operation. Change programs  
on-site using only a Memory Card and  
Programming Console, or use Memory  
Cards to store symbol tables or I/O  
(This function requires a CS1D-CPU@@S. CPU  
Unit, a CS1D-BC082 or CS1D-BI092 Backplane,  
and a CS1D-PA207R or CS1D-PD024 Power  
Supply Unit.)  
Flash memory (non-volatile memory) is built  
into the new CS1's CPU Unit. User  
programs and system parameters (e.g., PC  
Setup and data link tables) are automatically  
saved to this flash memory. This means that  
the new CS1 can operate without a Memory  
Card and battery.  
C200HX/HG/HE: Region comparison (ZCP  
and ZCPL) instructions.  
PC Card  
Adapter  
Easy replacement  
C200HX/HG/HE  
Faulty Unit  
CPU  
PS  
CS1  
CVM1/CV  
Memory Card  
(1) Remove the  
faulty Unit  
after stopping  
access to it.  
(2) Resume  
access after  
replacing the  
Unit.  
comments. Connecting a Programming  
Device allows monitoring operations with  
ladder programs with comments. It is also  
possible to save and read data such as DM  
data to a Memory Card during operation,  
and the Memory Cards are ideal for  
operations such as saving quality data and  
reading recipes.  
Built-in flash memory  
User program  
Parameter area data  
Upload  
CS1  
Store All I/O Comments, Symbol Names, Rung Comments, and Other  
Information in CPU Unit Comment Memory (See note.) (Unit Ver. 3.0 or later)  
When downloading projects, the Memory  
Card, EM file memory, or comment memory  
(in the CPU Unit's flash memory) can be  
selected as the transfer destination for I/O  
comments, symbol names, rung comments,  
and other data. This enables data such as  
I/O comments, symbol names, and rung  
comments to be stored in the CPU Unit's  
internal comment memory when a Memory  
Card or EM file memory are both not  
available.  
Battery-free  
operation  
with no Memory  
Card.  
Programming  
Console  
Production  
site  
Note: CX-Programmer Ver. 5.0 or higher required.  
F-14  
F-15  
Programmable CCoonnttrroolllleerr  
The CS1 Duplex System Boosts the  
Reliability of Facilities and Equipment  
Expansion Cables and Expansion Backplanes can be duplexed  
and replaced online.  
Duplex Networks between PLCs  
with Controller Link  
Even if one Unit fails, the other Unit will  
back it up and continue communications.  
Even if a line breaks, a loopback will be  
used to maintain the network.  
Expansion Cables can be  
duplexed and replaced online.  
By mounting Duplexed Expansion I/O Units  
and Expansion Cables, the Expansion  
Cables can be replaced during operation. In  
addition, problems such as cable  
disconnections are monitored, so the  
location of the failure can be easily identified.  
Expansion Backplanes can be  
added online.  
7
Even in systems where the power cannot  
be turned OFF or operation cannot be  
stopped, it is easy to add functions after  
system operation has started.  
Modifications can be easily made after  
startup for devices for which the power is  
not easily turned OFF.  
Either the CS1W-CLK13 or CS1W-CLK53 is  
required for a Duplex Controller Link network.  
Line backed  
up with  
Ethernet Unit  
Controller Link Unit  
Duplex CPU Units  
loopback  
Communications Units can be either duplexed or  
used individually.  
Duplex Power Supply Units  
Equipment in operation  
DPL01  
ETN21D  
RUN  
RUN  
DPL STATUS  
ACTIVE  
RUN  
ERC  
SD  
100M  
ERH  
TCP  
ERR/ALM  
ERR/ALM  
L
C
P
U
S
T
A
T
U
S
I
N
H
B
K
U
P
I
N
H
B
K
U
P
Power Supply Units can be either duplexed or  
used individually.  
RD  
ACTIVE  
R
LINK  
DPL  
P
R
P
H
L
C
O
M
M
C
P
U
S
T
A
T
U
S
P
R
P
H
L
C
O
M
M
UNIT  
NO.  
LEFT CPU  
USE  
SYSMAC  
CS1D-CPU67H  
SYSMAC  
CS1D-CPU67H  
PROGRAMMABLE CONTROLLER  
0
P
R
O
G
R
A
M
M
A
B
L
E
C
O
N
T
R
O
L
L
E
R
N
O
U
S
E
NODE  
NO.  
0
1
RIGHT CPU  
×16  
1
×16  
0
USE  
MCPWR  
OPEN  
BUSY  
MCPWR  
OPEN  
BUSY  
N
O
U
S
E
DPL SW  
ON  
OFF  
S
P
L
D
P
L
A
C
T
.
A
C
T
.
L
E
F
T
R
I
G
H
T
ON  
INIT.  
PERIPHERAL  
PERIPHERAL  
100BASE-TX  
10BASE-T  
SW  
Break  
PRPHL  
COMM  
A39512  
RSV  
PORT  
ON  
PORT  
DUPLEX  
Online Unit Replacement  
Hot Standby System Adopted for  
CPU Unit Duplexing  
When a problem occurs in the CPU Unit,  
the system instantly switches control to  
the other CPU Unit, enabling continuous  
operation with minimal effect on the  
system.  
No need to stop  
equipment to make  
additions.  
With either a Duplex-CPU or Single-CPU  
CS1D System, Basic I/O Units, Special I/O  
Units, and CPU Bus Units can be replaced  
online while the system continues operation.  
Although operation will stop for the Unit  
being replaced, all other Units will continue  
operation.  
Unit failed.  
Node backed up.  
Because there is no need for special  
duplex programming, the design process  
is simple and design steps are reduced.  
During System Operation with  
Power Supplied  
Rack added  
The system can also be configured with only one each  
of the CPU, Power Supply, and Communications Units.  
This lets you optimize the system cost by selecting the  
Units that you need. (The Duplex Unit must be used  
even when using only one each of the CPU, Power  
Supply, and Communications Units.)  
Perform the online Unit  
replacement operation  
from the Programming  
Console or CX-Programmer.  
Initial and maintenance costs  
are reduced.  
Unit  
replaced  
Program without Being Concerned with Duplex Operation  
Allows effective use of software  
assets.  
No special programming is required to use duplex communications with  
the CS1D, making it simple to design programs for duplex systems.  
The same support software can be used in  
systems combining the CS1 and CJ1 Series,  
and all software programs and data are  
compatible. Their application and reuse are  
extremely easy. There is also no need for  
ladder programs for duplexing. This means  
that when converting an existing system to a  
Duplex System, there is almost no need to  
revise ladder programs.  
Duplex operation is possible for any or all of the following:  
CPU Units, Power Supply Units, and Communications Units.  
The complex programming required in previous applications for duplex  
communications with Ethernet is eliminated.  
Use duplex operation for the CPU Unit,  
power supply, or communications  
these for systems that must never go down  
Previously it was necessary to program  
operation for both Ethernet Units.  
Just program the operation as if for one  
Ethernet Unit, and the PLC will determine  
the destination and send the message.  
or use duplex operation for only the power  
supply (which has a relatively short service  
life). Just build in the redundancy required  
by the system.  
depending on system requirements for  
reliability, costs, and functionality. For  
example, use duplex operation for all of  
Programming to  
determine destination  
PLC automatically determines  
destination.  
Tried first.  
SEND  
Destination  
SEND  
Other Unit tried if no  
Increase the Reliability of Information with Duplex Networks  
Duplex Ethernet for Greater Information Network Reliability  
response from first Unit.  
Complete compatibility among  
Units.  
SEND  
The CS1D Duplex System is fully compatible  
with the I/O Units of the entire CS Series.  
Accordingly, the same Units and materials  
can be used for restoring the system and  
conducting maintenance. There is no need  
to purchase different Units and materials for  
each system, making the CS1D Duplex  
System highly economical.  
With redundant networks and  
selected for each communications process  
(as opposed to switching the entire line), to  
enable creating a highly reliable network  
even against a network line broken in more  
than one location.  
Controller Link networks enable allocating data link areas without wasting  
memory.  
Communications Units, communications will  
continue even if a network line is broken or  
one of the Communications Units fails. The  
communications path is automatically  
Previously, twice  
the memory was  
required to  
implement data  
links for two  
Controller Link  
Units, and it was  
necessary to  
determine which  
data could be  
used.  
Just create the  
data links for one  
Controller Link Unit  
to eliminated  
wasted data  
memory. The  
Duplex Controller  
Link Units share  
the data links.  
Two sets of  
the same data  
link areas  
were required  
and  
programming  
was required  
to select the  
areas.  
This path is automatically selected.  
This path is automatically selected.  
(C200H Units, however, cannot be used with CS1D  
This path is automatically  
PLCs. Refer to user documentation for details.)  
selected.  
Unit failure  
Refer to CS1D Catalog (Cat. No.  
R103) for details.  
The CS1D-ETN21D and  
CS1D CPU Unit version  
1.1 or higher are  
required for a duplex  
Ethernet network.  
F-16  
F-17  
Machine performance improved with high-speed,  
high-precision, flexible motion control.  
Position Control Unit with  
Motion Control Units  
Customizable Counter Units  
Easy Data Control  
High-speed servo communications lets you  
MECHATROLINK-II interface  
Easy Programming with  
A Whole New Concept,  
Easy Control for Bending and  
read programs and parameter settings from  
G Language and Multitasking  
The Motion Control Units use G language to  
ensure easy programming. The Units have  
a large programming capacity of up to 100  
programs and 2,000 program blocks, and  
allow independent operation of 4 tasks.  
Customizable Counter Units  
A high-speed PLC with 20 I/O points, a  
2-axis high-speed counter, and 2 pulse or  
analog outputs have all been combined into 1  
Unit. The Customizable Counter Units allow  
easy execution of complicated applications.  
Pressing  
Single Cable Connection and  
Flexible Routing!  
With MECHATROLINK-II*, the Servo Drive  
CX-Programmer on a PC. You can also  
It is possible to switch between speed  
control and torque control from the ladder  
program, enabling bending operation for  
read and track the operating status of  
parameter settings inside the Servo Driver.  
can be easily connected with a single cable  
metals and pressing operation for bonding.  
(2-core shielded twisted pair cable). The  
CS1W-HCA22  
Easy Motion Control  
wire savings over the total length of 50 m (or  
30 m for 16 axes) enables Racks to be more  
freely located.  
Customizable  
Counter Unit  
Motion control, including positioning,  
synchronizing (electronic gears, electronic  
cams, tracking), speed, and torque control,  
can all be handled by the CS1.  
PLC  
20 I/O points  
High-speed Interlocks  
Interrupt programs can be executed from  
the motion control program using D codes  
(interrupt codes). Easy, fast interlocks  
ensure greater production efficiency.  
Synchronous control (electronic gears,  
electronic cams) is also possible.  
Torque Speed  
High-speed  
Pulse output  
PLC  
Time Saved in Startup and  
Maintenance  
Eight motion tasks can be used for  
simultaneous motion program execution.  
overhead  
0.1 ms  
Analog output  
Analog input  
Counter  
Servo Drive parameters can be set from the  
Position  
PLC.  
Settings and adjustments can be made from  
one location, without connecting the Support  
Software to individual Servo Drives. In  
addition, Servo Drive alarm status, speed,  
and torque monitoring can be centralized at  
the PLC.  
Position Control Unit with  
MECHATROLINK-II interface  
Motion Control Unit with  
MECHATROLINK-II interface  
Torque  
Torque Sensor  
Analog input  
Servo Driver  
CX-One  
Speed  
Position  
Control Unit  
Motion Control Units  
Customizable Counter Units  
CX-Programmer  
Position Control Units  
Two Types of Outputs and  
Servomotor  
Control of 1, 2, or 4 Axes  
Select from 1-axis, 2-axis, and 4-axis  
models with either open-collector output or  
line-driver output to suit a number of  
different applications.  
Motion Applications with  
High-speed Response  
A wide range of interrupt functions and  
superior response performance enable  
motion applications requiring high-speed  
response using pulse I/O.  
A Variety of Positioning Functions  
There are 2 operating modes: direct operation  
(position, speed, acceleration, and  
CX-Motion  
CX-Position  
CX-Motion-NCF  
CX-Motion-MCH  
deceleration data specified from the ladder  
program), which is effective for setting target  
positions, speeds, and acceleration rates  
immediately or during operation, and memory  
operation, where fixed patterns are stored  
beforehand in the Unit and used for operation.  
There are also a variety of positioning  
Note: MECHATROLINK-II is a registered trademark of the  
MECHATROLINK Members Association.  
Analog  
Pulse/analog output  
Com-  
Communications  
Pulses  
muni-  
cations  
OMNUC G-series/  
G5-series  
MECHATROLINK-II  
Servo Drive with  
Built-in  
OMNUC W-series  
OMNUC G-series/  
G5-series  
General-purpose  
Servo Drive  
SMART STEP  
2 Servo  
Drive with  
Pulse-string  
Input  
Servo Driver  
MECHATROLINK-II  
Servo Drive with  
Built-in  
functions, such as interrupt feeding, which is  
effective for feeder control, and forced interrupt,  
which is useful in emergencies.  
Communications  
Communications  
Motion Control Unit with  
Encoder  
MECHATROLINK-II interface  
Easy System Construction  
Up to 30 physical axes and two virtual axes,  
making a total of 32, can be controlled, and the  
servo interface is handled by high-speed servo  
communications (MECHATROLINK-II*). This  
makes it possible to control multiple axes with  
less wiring.  
Servomotor  
Servomotor  
Servomotor  
Servomotor  
Servomotor  
F-18  
F-19  
Smart Process Control OMRON PLC-based  
Process Control brings Major Innovations to Process Automation  
DCS functionality in a  
PLC  
Diversified Loop Control is even easier to use. Programming becomes even easier with function-block  
Analog Units with signal  
conversion functions  
programming.  
Depending on the function block software  
connections, all functions such as  
Example: Cascade Control (Heating and Cooling)  
A scalable system  
configuration  
PID1  
With Function  
Blocks:  
Isolated-type  
Ai4 Terminal  
9
Analog  
Input Unit Output Unit  
Analog  
Loop Control  
Unit  
operation block I/O combination  
Split  
Conversion  
Isolated-type  
Ao4 Terminal  
Basic PID  
specification can be achieved using only  
function blocks. Moreover, combining  
function blocks makes possible a wide  
array of control methods, from basic PID  
control to cascade control, feed forward  
control, and variable gain control.  
PV1  
PID1  
Y1  
Y2  
Y3  
Y4  
PV  
SP  
X1  
Y1  
Y2  
X1  
X2  
X3  
X4  
Y1  
Y2  
Y3  
Y4  
Down  
Down  
PVE Y1  
RSP MV  
MIE  
MV1  
Sizing  
Sizing  
RSP1  
PV2  
PID2  
MVE  
MV2  
Split  
conversion  
Function block  
programming  
Easy  
Easy  
Engineering  
Engineering  
Basic PID  
Duplex  
operation  
supported  
PV  
SP  
High  
High  
Sequence programming  
using either step ladders  
or sequence tables  
Temperature  
PVE Y1  
RSP MV  
MIE  
Reliability  
Reliability Complete  
maintenance  
functions  
MVE  
Temperature  
Heat  
A direct link to HMI  
products  
exchange  
Steam  
PID2  
Provides an exceptionally open environment with PLC-based process  
control to advance standardization and IT integration of the process  
control system.  
Cooling  
water  
Drain  
Operation, Monitoring, and Data Logging  
PLC-based Process Control Application Examples  
Touch Panels  
User Application  
HMI Software  
In-line Blending in a Food Plant  
Reaction Control in a Chemical Plant  
NS Series  
CX-Process Monitor Plus  
Compolet  
Communications  
Personal computer  
Personal computer  
programming between  
a PC and PLC can be  
accomplished easily  
with ActiveX control.  
NS Runtime  
Monitor display  
(data collection and  
saving)  
Monitor display  
(data collection and  
saving)  
Ethernet  
You can communicate  
with the PLC using the  
screen data created  
with the NS-series  
Support Software  
Ethernet  
SYSMAC CS1 Duplex  
(CS1D Process-control CPU Unit)  
SYSMAC CS1 PLC with advanced  
Loop Control Board  
Flowrate control  
(blended PID control)  
without modification.  
Reaction control  
Motor  
Control  
outputs  
Ethernet/Controller Link  
Materials tanks  
Flowrate  
A
Motor  
PLC (CS1 Duplex)  
PLC (CS Series)  
B
Product tanks  
CS1D Process-control  
CPU Unit  
Loop Control Board/Unit  
Condenses DCS functions in a  
compact Unit and enables  
function-block programming.  
CX-Process Tool  
Function blocks can be pasted  
into windows and graphic  
programming can be  
Motor  
Motor  
Motor  
Duplex Process-control CPU  
Unit can help reduce risk in  
systems that must not stop.  
A
B
C
Process I/O Units  
Analog I/O Units are available  
for diverse functions such as  
Isolators, power supplies, and  
signal conversion.  
Intermediate tank  
performed by arranging blocks  
with the mouse.  
Drying  
equipment  
F-20  
F-21  
MEMO  
System Design Guide  
System Configuration .........................................................................................2  
Dimensions/Mounting Dimensions .....................................................................9  
General Specifications......................................................................................11  
Common Specifications for CPU Units.............................................................12  
Current Consumption for Power Supply Units ..................................................15  
1
System Configuration  
Basic System Configuration  
CS1 Inner Boards  
CS1 CPU Units  
CS1 Power Supply Units  
Programming Devices  
Loop Control Board  
CS1W-LCB01/05  
Serial Communications Board  
CS1W-SCB21-V1  
CS1H-CPU@@H  
CS1G-CPU@@H  
C200HW-PA204C  
C200HW-PA204  
C200HW-PA204S  
C200HW-PA204R  
C200HW-PA209R  
C200HW-PD024  
C200HW-PD025  
CX-One  
(e.g., CX-Programmer)  
Programming Console  
CS1W-SCB41-V1  
Cable for  
Peripheral Port  
CS1 CPU Backplane  
CPU Rack  
Cable for Personal  
Computer  
CS1W-CN226/626  
For both CS1 and C200H Units  
CS1W-BC@@3  
(2, 3, 5, 8, or 10 slots)  
RUN  
ERR/ALM  
INH BKUP  
PRPHL COMM  
SYSMAC  
CS1D-CPU67S  
PROGRAMMABLE CONTROLLER  
MCPWR  
OPEN  
BUSY  
or  
PERIPHERAL  
Programmable  
For CS1 Unit only  
CS1W-BC@@2  
(2, 3, 5, 8, or 10 slots)  
Note:Cannot be used for C200H  
Unit.  
PORT  
Terminal (PT)  
NS Series  
Basic I/O Units  
Special I/O Units  
CPU Bus Units  
Memory Card  
HMC-EF183  
CS1 I/O  
Connecting Cable  
Expansion Racks  
RS-232C Cable  
for PT  
CS1W-CN@@3  
CS1 Expansion Rack  
(30 cm, 70 cm, 2 m, 3 m,  
5 m, 10 m, 12 m)  
XW2Z-200T/500T  
RS-232C Cable for  
IBM PC/AT or  
compatible  
Configuration Units Power Supply Unit  
CS1 I/O  
Connecting Cable  
CS1 Expansion  
Backplanes  
CS1 Expansion Rack  
computers  
For both CS1 and C200H Units  
CS1W-BI@@3  
(3, 5, 8, or 10 slots)  
XW2Z-200S/500S-CV  
Configuration Units Power Supply Unit  
or  
CS1 I/O  
Connecting Cable  
For CS1 Unit only  
CS1W-BI@@2  
RS-422A Adapter  
CS1 Expansion Rack  
(3, 5, 8, or 10 slots)  
Note:Cannot be used for C200H  
Unit.  
CJ1W-CIF11  
Configuration Units Power Supply Unit  
2
Programmable Controllers SYSMAC CS1G/H  
Configuration Units  
CS1 Basic I/O Units  
32-point Units  
Input Units  
8-point Units  
16-point Units  
64-point Units  
96-point Units  
DC Input Unit  
CS1W-ID211  
AC Input Unit  
CS1W-IA@11  
DC Input Unit  
CS1W-ID231  
DC Input Unit  
CS1W-ID261  
DC Input Unit  
CS1W-ID291  
---  
Output Units  
Triac Output Unit  
Transistor Output Units  
CS1W-OD21@  
Transistor Output Units  
CS1W-OD23@  
Transistor Output Units  
CS1W-OD26@  
Transistor Output Units  
CS1W-OD29@  
CS1W-OA201  
Relay Contact Output Unit Triac Output Unit  
(independent commons)  
CS1W-OC201  
CS1W-OA211  
Relay Contact Output Unit  
CS1W-OC211  
I/O Units  
---  
(32 inputs, 32 outputs)  
DC Input/Transistor  
Output Units  
(48 inputs, 48 outputs)  
DC Input/Transistor  
Output Units  
CS1W-MD26@  
CS1W-MD29@  
---  
---  
(32 inputs, 32 outputs)  
TTL I/O Unit  
CS1W-MD561  
Other Units  
Safety Relay Unit  
CS1W-SF200  
Interrupt Input Unit  
B7A Interface Units  
(32 inputs)  
B7A Interface Units  
(32 inputs, 32 outputs)  
CS1W-B7A22  
CS1W-INT01  
CS1W-B7A12  
(32 inputs)  
CS1W-B7A02  
(16 inputs, 16 outputs)  
CS1W-B7A21  
---  
Quick-response Input Unit  
CS1W-IDP01  
C200H Basic I/O Units and C200H Group-2 High-density I/O Units  
Input Units  
Output Units  
Interrupt Input Unit  
C200HS-INT01  
Analog Timer Unit  
C200H-TM001  
B7A Interface Units  
C200H-B7A@@@  
C200H-I@@@@  
C200H-O@@@@  
(Including group-2 high-  
density input units)  
(Including group-2 high-  
density output units)  
CS1 Special I/O Units, CPU Bus Units, and Inner Boards  
Temperature Sensor Input Units  
(Process I/O Units)  
CS1W-PTS@@  
High-speed Counter Units  
CS1W-CT0@@  
Serial Communications Units/  
Serial Communications Boards  
CS1W-SCB@1-V1  
CS1W-SCU@1-V1  
EtherNet/IP Unit  
CS1W-EIP21  
ID Sensor Units  
CS1W-V680C1@  
CS1W-V600C1@  
Customizable Counter Units  
CS1W-HCP22-V1  
Analog Input Units  
Analog Input Units  
CS1W-AD@@@(-V1)  
Isolated-type DC Input Units  
(Process I/O Units)  
CS1W-PDC@@  
GP-IB Interface Unit  
CS1W-GPI01  
High-speed Data Storage Unit  
CS1W-SPU0@-V2  
CS1W-HCA@2-V1  
CS1W-HIO01-V1  
Position Control Units  
CS1W-NC@@3  
Ethernet Unit  
CS1W-ETN21  
Position Control Unit with  
MECHATROLINK-II interface  
CS1W-NCF71  
Controller Link Units  
CS1W-CLK@3  
CS1W-PTW01  
CS1W-PTR0@  
SYSMAC Link Units  
CS1W-SLK@1  
Analog Output Units  
Analog Output Units  
CS1W-DA0@@  
CS1W-NC@71  
Motion Control Units  
CS1W-MC@21-V1  
FL-net Unit  
CS1W-FLN22  
Isolated-type Control Output  
Units  
Motion Control Unit with  
MECHATROLINK-II interface  
CS1W-MCH71  
DeviceNet Units  
CS1W-DRM21-V1  
CompoNet Master Unit  
CS1W-CRM21  
(Process I/O Units)  
CS1W-PMV0@  
Analog I/O Units  
CS1W-MAD44  
CompoBus/S Master Unit  
CS1W-SRM21  
Isolated-type Pulse Input Units  
(Process I/O Units)  
CS1W-PPS01  
Loop Control Board  
CS1W-LCB0@  
C200H Special I/O Units  
I/O Units  
High-speed Counter Units  
C200H-CT@@@(-V1)  
Cam Positioner Unit  
C200H-CP114  
DeviceNet Master Unit  
C200HW-DRM21-V1  
CompoBus/S Master Unit  
C200HW-SRM21-V1  
PC Link Unit  
ID Sensor Units  
C200H-IDS01-V1  
ASCII Units  
(Special I/O Units)  
C200H-ID@@@  
C200H-OD@@@  
C200H-ASC@@  
C200H-MD@@@  
Position Control Units  
C200HW-NC@@3  
Temperature Sensor Units  
C200H-TS@@@  
C200H-LK401  
Motion Control Units  
C200H-MC221  
SYSBUS Bus Remote I/O Master  
Units  
C200H-RM@@@(-PV1)  
Analog Input Units  
C200H-AD@@@  
Analog Output Units  
C200H-DA@@@  
Analog I/O Units  
C200H-MAD01  
Temperature Control Units  
C200H-TC@@@  
Heat/Cool Control Units  
C200H-TV@@@  
PID Control Units  
C200H-PID0@  
Programmable Controllers SYSMAC CS1G/H  
3
CS1 CPU Rack  
A CS1 CPU Rack consists of a CPU Unit, Power Supply Unit, and Configuration Units (Basic I/O Units, Special I/O Units, and CPU Bus  
Units).  
CS1 CPU Backplane  
CS1 CPU Unit  
Power Supply Unit  
CS1W-BC@@@ (See note.)  
CS1G/H-CPU@@H  
C200HW-P@@@@(@)  
RUN  
ERR/ALM  
INH BKUP  
PRPHL COMM  
SYSMAC  
CS1D-CPU67S  
PROGRAMMABLE CONTROLLER  
MCPWR  
OPEN  
BUSY  
CPU Rack  
PERIPHERAL  
PORT  
Basic I/O Units  
Special I/O Units  
CPU Bus Units  
Note: C200H Units cannot be used on the CPU Rack or Expansion Racks  
if a CS-series-only CPU Backplane (CS1W-BC@@3) is used.  
Required Units  
Rack  
Unit name  
Required number of units  
CS1 CPU Backplane (CS1W-BC@@@)  
Power Supply Unit  
1
1
CPU Rack  
CPU Unit  
1
Maximum Number of Configuration Units  
Varies by backplane model  
Types of Units  
In the SYSMAC CS Series, Units are classified into the following three types. The number of Racks differs depending on the type.  
Type  
Appearance (example)  
Description  
Unit recognition method  
No. of Units  
In the CS1 System, CS1  
Basic I/O Units, C200H  
Basic I/O Units, and  
Group-2 High-density I/O  
Units are identified by  
their mounting positions  
(Rack and slot).  
The Units mounted must  
not exceed the maximum  
I/O capacity of the CPU  
Unit.  
Units with contact inputs and contact  
outputs.  
CS1 Basic I/O Units  
C200H Basic I/O Units  
Basic I/O Units  
C200H Group-2 High-density  
I/O Units  
Special I/O Units provide more  
advanced functions than do Basic I/O  
Units, including I/O other than contact  
inputs and contact outputs.  
Examples of Special I/O Units are  
Analog I/O Units and High-speed  
Counter Units. They differ from CPU  
Bus Units (including Network  
Recognized by the CPU  
Unit according to the unit Units: 96 Units max.;  
number (CS-series C200H Special I/O Units:  
Special I/O Units: 0 to 95, 10 or 16 Units max. (From  
C200J Special I/O Units: 1 to 4 unit numbers are  
0 to 9, or 0 to 15) set with assigned per Unit,  
the rotary switches on the depending on the model  
CS-series Special I/O  
Special I/O Units  
Communications Units) in having a  
smaller area for exchanging data with  
the CPU Unit.  
front panel.  
of the Unit.)  
CS1 Special I/O Units  
C200H Special I/O Units  
CPU Bus Units exchange data with  
the CPU Unit via the CPU Bus.  
Examples of CPU Bus Units are  
Network Communications Units and  
Serial Communications Units.  
They differ from Special I/O Units in  
having a larger area for exchanging  
data with the CPU Unit.  
Recognized by the CPU  
Unit according to the unit  
number (0 to F) set with  
the rotary switch on the  
front panel.  
A maximum of 16 Units  
can be mounted.  
CPU Bus Units  
CS1 CPU Bus Units  
4
Programmable Controllers SYSMAC CS1G/H  
CS1 Expansion Racks  
CS1 CPU Racks and Expansion Racks  
Use this system configuration for an expansion of 12 m or less.  
CPU Rack  
Expansion Racks Configuration  
Unit name  
Required number of units  
Expansion  
Backplane  
(CS1W-BI@@@)  
One required for each  
Expansion Rack  
CS1 I/O  
Connecting Cable  
CS1W-CN@@3  
CS1  
Expansion  
Rack  
Power Supply Unit  
C200HW-P@@@@(@)  
One required for each  
Expansion Rack  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
Maximum Number  
of Configuration  
Units  
Varies by backplane model  
CS1 I/O  
Connecting Cable  
CS1  
Expansion  
Rack  
Power Supply Unit  
C200HW-P@@@@(@)  
• Cable  
CS1W-CN@@3  
12 m  
CS1 Expansion Backplane  
CS1W-BI@@@  
Cable name  
Required number of Cables  
CS1 I/O Connecting  
Cable  
(CS1W-CN@@3)  
One required for each  
Expansion Rack  
CS1 I/O  
Connecting Cable  
Power Supply Unit  
C200HW-P@@@@(@)  
CS1  
Expansion  
Rack  
CS1W-CN@@3  
CS1 Expansion Backplane  
CS1W-BI@@@  
Programmable Controllers SYSMAC CS1G/H  
5
When Using a C200HX/HG/HE Expansion I/O Rack  
It is possible to connect to an existing C200HX/HG/HE Expansion I/O Rack.  
CS1 CPU Rack, CS1 Expansion Racks, and C200HX/HG/HE Expansion I/O Racks  
CPU Rack  
Expansion Racks Configuration  
• CS1 Expansion Racks  
Unit name  
Required number of units  
Expansion Backplane  
(CS1W-BI@@@)  
CS1 I/O Connecting Cable  
CS1W-CN@@3  
1
CS1 Expansion Rack  
(See note.)  
CS1 Expansion  
Backplane  
Power Supply Unit  
1
CS1W-BI@@@  
Maximum Number of  
Configuration Units  
Power Supply Unit  
C200HW-P@@@@(@)  
Varies by backplane model  
• C200HX/HG/HE Expansion Racks  
CS1 to C200H I/O  
Connecting Cable  
CS1W-CN@@1  
C200HX/HG/HE  
Expansion  
Unit name  
Required number of units  
12 m  
C200HX/HG/HE Expansion  
I/O Rack  
I/O Backplane  
C200HW-BI@@@  
C200HX/HG/HE  
Expansion I/O  
Backplane  
One required for each  
Expansion Rack  
Power Supply Unit  
C200HW-P@@@@(@)  
(C200HW-BI@@@)  
One required for each  
Expansion Rack  
C200H I/O  
Connecting  
Cable  
Power Supply Unit  
C200HX/HG/HE  
Expansion  
I/O Backplane  
C200HW-BI@@@  
C200H-CN@@1  
Maximum Number of  
Configuration Units  
C200HX/HG/HE Expansion  
I/O Rack  
Varies by backplane model  
Power Supply Unit  
C200HW-P@@@@(@)  
• Cables  
Cable name  
Required number of cables  
CS1 I/O Connecting  
Cable  
(CS1W-CN@@3)  
Note: Multiple CS1 Expansion Racks can be connected, but the total number of Expansion Racks  
must not exceed the maximum of 7. In addition, the Racks must be connected in order, with  
CS1 Expansion Racks connected before C200HX/HG/HE Expansion I/O Racks.  
Number of CS1 Expansion  
Racks  
CS1 to C200H I/O  
Connecting Cable  
(CS1W-CN@@1)  
1
C200H I/O Connecting Number of C200HX/HG/HE  
Cable  
(C200H-CN@@1)  
Expansion I/O Racks  
minus 1  
CS1 CPU Rack and C200HX/HG/HE Expansion I/O Racks  
CPU Rack  
Expansion Racks Configuration  
• C200HX/HG/HE Expansion I/O Racks  
Unit name  
Required number of units  
C200HX/HG/HE  
Expansion I/O  
Backplane  
CS1 to C200H I/O  
Connecting Cable  
One required for each  
Expansion Rack  
C200HX/HG/HE  
CS1W-CN@@1  
C200HX/HG/HE I/O  
Expansion  
Expansion Rack  
I/O Backplane  
C200HW-BI@@@  
(C200HW-BI@@@)  
Power Supply Unit  
C200HW-P@@@@(@)  
One required for each  
Expansion Rack  
Power Supply Unit  
Maximum Number of  
Configuration Units  
C200H I/O  
Connecting Cable  
C200H-CN@@1  
Varies by backplane model  
12 m  
C200HX/HG/HE  
Expansion  
I/O Backplane  
C200HW-BI@@@  
C200HX/HG/HE I/O  
Expansion Rack  
• Cables  
Power Supply Unit  
C200HW-P@@@@(@)  
Cable name  
Required number of cables  
CS1 to C200H I/O  
Connecting Cable  
(CS1W-CN@@1)  
1
C200H I/O  
Connecting Cable  
C200H-CN@@1  
C200HX/HG/HE  
Expansion  
I/O Backplane  
C200HW-BI@@@  
C200HX/HG/HE I/O  
Expansion Rack  
C200H I/O Connecting Number of C200HX/HG/HE  
Cable  
(C200H-CN@@1)  
Expansion I/O Racks  
minus 1  
Power Supply Unit  
C200HW-P@@@@(@)  
6
Programmable Controllers SYSMAC CS1G/H  
Long-distance Expansion  
Use this system configuration for an expansion of more 12 m. Expansion is possible by up to 50 m.  
Using CS1 Connecting Cable and Long-distance Expansion Connecting Cable  
CPU Rack  
(Used for long-distance expansion.)  
CS1 I/O Connecting Cable CS1W-CN@@3  
0.7 m  
I/O Control Unit (see note.)  
CS1W-IC102  
CS1 Expansion Rack  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
C200HW-P@@@@(@)  
Connecting Cable for Long-distance Expansion CV500-CN@@2  
Connecting Cable for Long-distance Expansion CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
Power Supply Unit  
C200HW-P@@@@(@)  
C200HW-P@@@@(@)  
50 m  
Connecting Cable for Long-distance Expansion  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
Power Supply Unit  
C200HW-P@@@@(@)  
C200HW-P@@@@(@)  
50 m  
Connecting Cable for Long-distance Expansion  
Terminator *  
CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
C200HW-P@@@@(@)  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
*
Two Terminators (CV500-TER01) are provided with  
the CS1W-IC102 I/O Control Unit.  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
C200HW-P@@@@(@)  
Expansion Racks Configuration  
• CS1 Expansion Rack  
Terminator *  
Note: If even one Long-distance Expansion Connecting Cable to be used, it is necessary for an  
I/O Control Unit to be mounted to the CS1 Expansion Rack where the Cable is connected.  
Unit name  
Required number of units  
I/O Control Unit  
(CS1W-IC102)  
1
• CS1 Expansion Rack (Long-distance  
expansion)  
Unit name  
Required number of units  
CS1 Expansion  
Backplane  
(CS1W-BI@@@)  
One required for each  
Expansion Rack  
One required for each  
Expansion Rack  
Power Supply Unit  
I/O Interface Unit  
(CS1W-II102)  
One required for each  
Expansion Rack  
Maximum Number of  
Configuration Units  
Varies by backplane model  
• Cable  
Cable name  
Required number of cables  
CS1 I/O Connecting  
Cable  
1
(CS1W-CN@@3)  
Connecting Cable for  
Long-distance  
Expansion  
Number of CS1 Expansion  
Racks minus 1  
(CV500-CN@@2)  
Programmable Controllers SYSMAC CS1G/H  
7
Using Long-distance Expansion Connecting Cable  
I/O Control Unit  
CS1W-IC102  
CPU Rack  
(Used for long-distance expansion.)  
Connecting Cable for Long-distance Expansion CV500-CN@@2  
Connecting Cable for Long-distance Expansion CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
CS1 Expansion Rack  
CS1 Expansion Backplane  
CS1W-BI@@@  
(Used for long-distance expansion.)  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
C200HW-P@@@@(@)  
Power Supply Unit  
C200HW-P@@@@(@)  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
50 m  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
Power Supply Unit  
C200HW-P@@@@(@)  
C200HW-P@@@@(@)  
50 m  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
I/O Interface Unit  
CS1W-II102  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
Power Supply Unit  
C200HW-P@@@@(@)  
C200HW-P@@@@(@)  
Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
Terminator *  
I/O Interface Unit  
CS1W-II102  
CS1 Expansion Rack  
(Used for long-distance expansion.)  
CS1 Expansion Backplane  
CS1W-BI@@@  
Power Supply Unit  
C200HW-P@@@@(@)  
*
Two Terminators (CV500-TER01) are provided  
with the CS1W-IC102 I/O Control Unit.  
Terminator *  
CS1 CPU Rack  
Unit name  
Required number of units  
I/O Control Unit  
(CS1W-IC102)  
1
Expansion Racks Configuration  
• CS1 Expansion Rack (Long-distance  
expansion)  
Unit name  
Required number of units  
CS1 Expansion  
Backplane  
(CS1W-BI@@@)  
One required for each  
Expansion Rack  
One required for each  
Expansion Rack  
Power Supply Unit  
I/O Interface Unit  
(CS1W-II102)  
One required for each  
Expansion Rack  
Maximum Number of  
Configuration Units  
Varies by backplane model  
• Cable  
Cable name  
Required number of cables  
Connecting Cable for  
Long-distance  
Expansion  
Number of Long-distance  
Expansion Racks  
(CV500-CN@@2)  
8
Programmable Controllers SYSMAC CS1G/H  
Dimensions/Mounting Dimensions  
(Unit: mm)  
External Dimensions  
Backplane Mounting Dimensions  
For 2 I/O Slots  
4-M4  
198.5  
RUN  
ERR  
INH  
POWER  
COMM  
SYSMAC C200HX  
PROGRAMMABLE CONTROLLER  
CPU64  
H
B
CPU Backplane  
CS1W-BC023  
157  
145 0.3  
A
D
W
172.3 0.3  
Note: An Expansion Backplane cannot be connected to a 2-slot CPU  
Backplane.  
Backplane model  
A
B
W
H
D *  
CS1W-BC022/023  
(2 slots)  
For 3, 5, 8, or 10 I/O Slots  
172.3  
246  
145  
198.5  
260  
330  
435  
505  
157  
123  
6
CS1W-BC032/033  
(3 slots)  
A
0.3  
4-M4  
118  
118  
118  
118  
132  
132  
132  
132  
123  
123  
123  
123  
6
CS1W-BC052/053  
(5 slots)  
135  
(including132  
316  
118 0.3  
CPU Backplane  
protrusion) *  
CS1W-BC082/083  
(8 slots)  
421  
66 min.  
80  
6
CS1W-BC102/103  
(10 slots)  
A
0.3  
6
491  
*
The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit.  
The depth is 111 mm for the C200HW-PA204C Power Supply Unit.  
135  
(including132  
118 0.3  
Expansion Backplane  
W
protrusion) *  
4-M4  
* The CS1D Backplane has no protrusions.  
Product name  
Model  
A
W
CS1W-BC022/023  
(2 slots)  
172.3  
198.5  
CS1W-BC032/033  
(3 slots)  
246  
316  
421  
491  
246  
316  
421  
491  
175  
245  
350  
420  
260  
330  
435  
505  
260  
330  
435  
505  
189  
259  
364  
434  
CS1W-BC052/053  
(5 slots)  
CPU Backplanes  
CS1W-BC082/083  
(8 slots)  
CS1W-BC102/103  
(10 slots)  
CS1W-BI032/033  
(3 slots)  
CS1W-BI052/053  
(5 slots)  
CS1  
Expansion  
Backplane  
CS1W-BI082/083  
(8 slots)  
CS1W-BI102/103  
(10 slots)  
Expansion  
Backplanes  
C200HW-BI031  
(3 slots)  
C200HW-BI051  
(5 slots)  
C200HX/HG/HE  
Expansion  
Backplane  
C200HW-BI081-V1  
(8 slots)  
C200HW-BI101-V1  
(10 slots)  
Programmable Controllers SYSMAC CS1G/H  
9
Mounting Height  
The mounted height of CPU Racks, Expansion Racks, and Slave  
Racks is 118 to 153 mm, depending on I/O Units that are  
mounted.  
CS1 I/O Connecting Cable  
R
R 69 mm required  
If Programming Devices or connecting cables are attached, the  
additional dimensions must be taken into account. Allow sufficient  
clearance in the control panel in which the PLC is mounted.  
Note: Cable thickness: 8.6 mm dia.  
C200H I/O Connecting Cable  
Note: When using Expansion Racks, the total  
length of the I/O Connecting Cables  
must be less than 12 m. When bending  
R 41 mm required  
118 mm to 153 mm  
an I/O Connecting Cables, provide at  
least the minimum bending radius  
shown in the following diagrams.  
180 mm to 223 mm  
R
Note: Cable thickness: 5.1 mm dia.  
CS1 to C200H I/O Connecting Cable  
R
R 41 mm required  
Note: Cable thickness: 5.1 mm dia.  
Connecting Cable for Long-distance Expansion  
R
R 80 mm required  
Note: Cable thickness: 10 mm dia.  
10  
Programmable Controllers SYSMAC CS1G/H  
General Specifications  
Specifications  
Power Supply  
C200HW-PA204  
C200HW-PA204C  
C200HW-PA204R  
C200HW-PA204S  
C200HW-PA209R  
C200HW-PD024  
C200HW-PD025  
Unit model  
Item  
Power supply  
voltage  
100 to 240 VAC (wide range), 50/60 Hz *1  
100 to 120 VAC/200 to 240 V, 50/60 Hz  
85 to 132 VAC/170 to 264 V  
24 VDC  
Operating voltage  
range  
85 to 264 VAC  
19.2 to 28.8 VDC  
40 W max.  
120 VA max.  
100 VA max.  
120 VA max.  
180 VA max.  
60 W max.  
Power consumption  
100 to 120 VAC input  
20 A/8 ms max. (cold  
100 to 120 VAC:  
start at room  
100 to 120 VAC input 15 A/8 ms max. (cold start at room temperature)  
200 to 240 VAC input 30 A/8 ms max. (cold start at room temperature)  
30 A max.  
temperature) 200 to  
200 to 240 VAC:  
240 VAC input 30 A/8  
40 A max.  
30 A max.  
Inrush current  
ms max. (cold start  
at room temperature)  
• 20 MΩ min. (at 500 VDC)  
between all AC external  
20 MΩ min. (at 500  
VDC) between AC  
external and GR  
terminals *2  
terminals and GR terminal  
and between all alarm  
output terminals.  
• 20 MΩ min. (at 250 VDC)  
between all alarm output  
terminals and GR terminal.  
20 MΩ min. (at 500 VDC) between all AC external and GR  
terminals *2  
20 MΩ min. (at 500 VDC) between all DC  
external and GR terminals *2  
Insulation resistance  
• 2,300 VAC, 50/60 Hz for 1  
minute between all AC  
external terminals and GR  
terminal and between all  
alarm output terminals.  
Leakage current: 10 mA  
max.  
• 1,000 VAC, 50/60 Hz for 1  
minute between all alarm  
output terminals and GR  
terminal. Leakage current:  
10 mA max.  
2,300 VAC 50/60 Hz  
for 1 min between AC  
external and GR  
terminals *2  
Leakage current:  
10 mA max.  
2,300 VAC 50/60 Hz for 1 min between all AC external and GR  
terminals *2  
Leakage current: 10 mA max.  
1,000 VAC 50/60 Hz for 1 min between all  
DC external and GR terminals *2  
Leakage current: 10 mA max.  
Dielectric strength  
1,000 VAC 50/60 Hz for 1 min between all DC external and GR terminals *2  
Leakage current: 10 mA max.  
Noise immunity  
2 kV on power supply line (conforming to IEC61000-4-4)  
Conforms to JIS 0040, 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes (Time coefficient: 8 minutes  
x coefficient factor 10 = total time 80 min.)  
Vibration resistance  
Shock resistance  
(CPU Unit mounted to a DIN track: 2 to 55 Hz, 2.9 m/s2 in X, Y, and Z directions for 20 minutes)  
Conforms to JIS 0041, 147 m/s2 3 times each in X, Y, and Z directions  
Ambient operating  
temperature  
0 to 55°C  
Ambient operating  
humidity  
10% to 90% (with no 10% to 90%  
10% to 90% (with no condensation)  
condensation)  
(with no condensation) *4  
Ambient operating  
atmosphere  
No corrosive gases  
Ambient storage  
temperature  
-20 to 75°C (excluding battery)  
Less than 100 Ω  
Grounding  
Enclosure  
Weight  
Mounted in a panel.  
Each Rack: 6 kg max.  
2 slots: 198.5 x 157 x 123 (W x H x D) *3  
3 slots: 260 x 130 x 123 (W x H x D) *3  
5 slots: 330 x 130 x 123 (W x H x D) *3  
8 slots: 435 x 130 x 123 (W x H x D) *3  
10 slots: 505 x 130 x 123 (W x H x D) *3  
CPU Rack  
dimensions (mm)  
Conforms to UL, CSA, cULus, NK, Lloyds, and EC Directives.  
Standards  
*1. C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz.  
*2. Disconnect the Power Supply Unit’s LG terminal from the GR terminal when testing insulation and dielectric strength.  
Testing the insulation and dielectric strength with the LG terminal and the GR terminals connected will damage internal circuits in the CPU Unit.  
*3. The depth is 153 mm for the C200HW-PA209R/PD025 Power Supply Unit. The depth is 111 mm for the C200HW-PA204C Power Supply Unit.  
*4. Maintain an ambient storage temperature of -25 to 30°C and relative humidity of 25% to 70% when storing the C200HW-PA204C for longer than 3 months to  
keep the replacement notification function in optimum working condition.  
Programmable Controllers SYSMAC CS1G/H  
11  
Common Specifications for CPU Units  
Item  
Specifications  
Stored program  
Control method  
Cyclic scan and immediate processing are both possible.  
I/O control method  
•Ladder diagrams  
•SFC (sequential function charts)  
•ST (structured text)  
•Mnemonics  
Programming  
1 to 7 steps per instruction  
Approx. 400 (3-digit function codes)  
0.02 μs min.  
Instruction length  
Ladder instructions  
Basic instructions  
Execution time  
0.04 μs min.  
Special instructions  
288 (cyclic tasks: 32, interrupt tasks: 256)  
Note 1:Cyclic tasks are executed each cycle and are controlled with TKON(820) and TKOF(821) instructions.  
2:The following 4 types of interrupt tasks are supported. Power OFF interrupt tasks: 1 max. Scheduled interrupt tasks: 2 max. I/O in-  
terrupt tasks: 32 max. External interrupt tasks: 256 max.  
Number of tasks  
Scheduled Interrupts: Interrupts generated at a time scheduled by the CPU Unit’s built-in timer.  
I/O Interrupts: Interrupts from Interrupt Input Units.  
Power OFF Interrupts: Interrupts executed when the CPU Unit’s power is turned OFF.  
External I/O Interrupts: Interrupts from the Special I/O Units, CS-series CPU Bus Units, or the Inner Board.  
Interrupt types  
Languages in function block definitions: ladder programming, structured text  
Function blocks *1  
I/O Area  
5,120: CIO 000000 to CIO 031915 (320 words from CIO 0000 to CIO 0319)  
The setting of the first word can be changed from the default (CIO 0000) so that CIO 0000 to CIO 0999 can be used.  
I/O bits are allocated to Basic I/O Units, such as CS-series Basic I/O Units, C200H Basic I/O Units, and C200H Group-2  
High-density I/O Units.  
3,200 (200 words): CIO 10000 to CIO 119915 (words CIO 1000 to CIO 1199)  
Link bits are used for data links and are allocated to Units in Controller Link Systems and PLC Link Systems.  
Link Area  
6,400 (400 words): CIO 150000 to CIO 189915 (words CIO 1500 to CIO 1899)  
CS-series CPU Bus Unit bits store the operating status of CS-series CPU Bus Units.  
(25 words per Unit, 16 Units max.)  
CPU Bus Unit Area  
15,360 (960 words): CIO 200000 to CIO 295915 (words CIO 2000 to CIO 2959)  
Special I/O Unit bits are allocated to CS-series Special I/O Units and C200H Special I/O Units. (See Note.)  
(10 words per Unit, 96 Units max. The maximum total number of slots, however, is limited to 80 including expansion slots, so  
the maximum number of Units is actually 80.  
Special I/O Unit Area  
The CIO  
Area can be  
used as work  
Note: A maximum of 16 C200H Special I/O Units can be mounted. Also, depending on the Units, the maximum may be 10.  
Some I/O Units are classified as Special I/O Units.  
CIO (Core I/O)  
Area  
1,600 (100 words): CIO 190000 to CIO 199915 (words CIO 1900 to CIO 1999)  
bits if the bits  
Inner Board Area  
Inner Board bits are allocated to Inner Boards. (100 I/O words max.)  
are not used  
800 (50 words): CIO 300000 to CIO 304915 (words CIO 3000 to CIO 3049)  
as shown  
SYSMAC BUS bits are allocated to Slave Racks connected to SYSMAC BUS Remote I/O Master Units. (10 words per Rack, here.  
5 Racks max.)  
SYSMAC BUS Area  
512 (32 words): CIO 310000 to CIO 313115 (words CIO 3100 to CIO 3131)  
I/O Terminal bits are allocated to I/O Terminal Units (but not to Slave Racks) connected to SYSMAC BUS Remote I/O  
Master Units. (1 word per Terminal, 32 Terminals max.)  
I/O Terminal Area  
C200H Special I/O Unit  
Area  
8,192 bits (512 words): W00000 to W51115 (W000 to W511)  
C200H Special I/O Unit bits are allocated to C200H Special I/O Units, and accessed separately from I/O refreshing.  
1,600 (100 words): Outputs: CIO 005000 to CIO 009915 (words CIO 0050 to CIO 0099)  
Inputs: CIO 035000 to CIO 039915 (words CIO 0350 to CIO 0399)  
DeviceNet bits are allocated to Slaves according to DeviceNet remote I/O communications.  
DeviceNet Area  
PLC Link Area  
64 bits (4 words): CIO 024700 to CIO 025015 (words CIO 0247 to CIO 0250)  
When a PLC Link Unit is used in a PLC Link, use these bits to monitor PLC Link errors and the operating status of other  
CPU Units in the PLC Link.  
4,800 (300 words): CIO 120000 to CIO 149915 (words CIO 1200 to CIO 1499)  
Internal I/O Area  
Work Area  
37,504 (2,344 words): CIO 380000 to CIO 614315 (words CIO 3800 to CIO 6143)  
These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.)  
8,192 bits (512 words): H00000 to H51115 (H000 to H511)  
These bits in the CIO Area are used as work bits in programming to control program execution. (They cannot be used for external I/O.)  
When using work bits in programming, use the bits in the Work Area first before using bits from other areas.  
8,192 bits (512 words): H00000 to H51115 (H000 to H511)  
Holding bits are used to control the execution of the program, and maintain their ON/OFF status when the PLC is turned OFF or the  
operating mode is changed.  
Holding Area  
Note: The Function Block Holding Area words are allocated from H512 to H1535. These words can be used only for the function block  
instance area (internally allocated variable area).  
Read only: 7,168 bits (448 words): A00000 to A44715 (words A000 to A447)  
Read/write: 8,192 bits (512 words): A44800 to A95915 (words A448 to A959)  
Auxiliary bits are allocated specific functions.  
Auxiliary Area  
16 bits (TR0 to TR15)  
Temporary Area  
Temporary bits are used to temporarily store the ON/OFF execution conditions at program branches.  
4,096: T0000 to T4095 (separate from counters)  
Note: The time units for timer settings are 0.1 s, 0.01 s, and 0.001 s (depending on the timer instruction that is used).  
Timer Area  
C0000 to C4095 (separate from timers)  
Counter Area  
32K words: D00000 to D32767  
Internal Special I/O Unit DM Area: D20000 to D29599 (100 words x 96 Units)  
Used to set parameters for Special I/O Units.  
CPU Bus Unit DM Area:  
D30000 to D31599 (100 words x 16 Units)  
Used to set parameters for CPU Bus Units.  
D32000 to D32099  
DM Area  
Inner Board DM Area:  
Used to set parameters for Inner Boards.  
Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the DM Area maintain their status when  
the PLC is turned OFF or the operating mode is changed.  
12  
Programmable Controllers SYSMAC CS1G/H  
Item  
Specifications  
32K words per bank, 13 banks max.: E0_00000 to EC_32767 max. (Varies by CPU Unit model.)  
Used as a general-purpose data area for reading and writing data in word units (16 bits). Words in the EM Area maintain their status when  
the PLC is turned OFF or the operating mode is changed.  
EM Area  
The EM Area is divided into banks, and the addresses can be set by either of the following methods.  
Changing the current bank using the EMBC(281) instruction and setting addresses for the current bank. Setting bank numbers and  
addresses directly.  
EM data can be stored in files by specifying the number of the first bank.  
DR0 to DR15: Store offset values for indirect addressing. One register is 16 bits (1 word).  
Data Registers  
Index Registers  
IR0 to IR15: Store PLC memory addresses for indirect addressing. One register is 32 bits (2 words).  
32 (TK0000 to TK0031): Task Flags are read-only flags that are ON when the corresponding cyclic task is executable and OFF when the  
corresponding task is not executable or in standby status.  
Task Flag Area  
Trace Memory  
File Memory  
4,000 words (The maximum amount of data that can be traced in a data trace is 500 samples for 31 bits and 6 words.  
Memory Cards: Compact flash memory cards can be used (MS-DOS format).  
EM file memory: Part of the EM Area can be converted to file memory (MS-DOS format).  
Parallel Processing  
Modes  
Program execution and peripheral servicing can be performed simultaneously.  
The user program and the system’s parameters are backed up automatically in flash memory, which is standard equipment.  
Possible (1 to 32,000 ms) (Unit: 1 ms)  
Battery-free operation  
Constant cycle time  
Cycle time monitoring  
I/O refreshing  
Possible (Unit stops operating if the cycle is too long): 10 to 40,000 ms (Unit: 10 ms)  
Cyclic refreshing, immediate refreshing, refreshing with I/O REFRESH instruction  
I/O memory holding  
when changing  
Possible (Depends on the ON/OFF status of the IOM Hold Bit in the Auxiliary Area.)  
All outputs on Output Units can be turned OFF.  
operating modes  
Load OFF  
Time constants can be set for inputs from Basic I/O Units.  
The time constant can be increased to reduce the influence of noise and chattering or it can be decreased to detect shorter pulses on the  
inputs (CS1 Basic I/O Units only).  
Input response time  
setting  
Supported.  
Startup mode setting  
Automatically reading programs (autoboot) from the Memory Card when the power is turned ON.  
User program: Program file format  
Format in which data is stored in Memory Card  
PLC Setup and other parameters: Data file format (binary format)  
I/O memory: Data file format (binary format), text format, or CSV format  
Memory Card  
functions  
Functions for which Memory Card read/write is  
supported  
User program instructions, Programming Devices (including Programming Consoles),  
Host Link computers  
Memory Card data and the EM (Extended Data Memory) Area can be handled as files.  
Filing  
Control set/reset, differential monitoring, data tracing (scheduled, each cycle, or when instruction is executed), storing location generating  
error when a program error occurs  
Debugging  
User programs can be overwritten in program-block units when the CPU Unit is in MONITOR or PROGRAM mode.  
(This function is not available for block programming areas.)  
Online editing  
Overwrite protection: Set using DIP switch.  
Copy protection: Password set using Programming Device.  
Program protection  
User-defined errors (i.e., user can define fatal errors and non-fatal errors)  
The FPD(269) instruction can be used to check the execution time and logic of each programming block.  
Error check  
Error log  
Up to 20 errors are stored in the error log. Information includes the error code, error details, and the time the error occurred.  
Functions  
Built-in peripheral port: Programming Device (including Programming Console) connections, Host Links, NT Links  
Built-in RS-232C port: Programming Device (excluding Programming Console) connections, Host Links, no-protocol communications, NT  
Links, and Serial Gateway *3  
Serial  
communications  
Serial communications board (order separately): protocol macros, Host Links, no-protocol communications *3, NT Links, Serial Gateway  
*3, and Modbus-RTU Slave *5  
Provided on all models.  
Note: Used to store the time when power is turned ON and when errors occur.  
Clock  
Power OFF detection  
time  
10 to 25 ms (not fixed)  
Power OFF detection  
delay time  
0 to 10 ms (user-defined, default: 0 ms)  
Held Areas: Holding bits, contents of Data Memory and Extended Data Memory, and status of the counter Completion Flags and present  
values.  
Note: If the IOM Hold Bit in the Auxiliary Area is turned ON, and the PLC Setup is set to maintain the IOM Hold Bit status when power to  
the PLC is turned ON, the contents of the CIO Area, the Work Area, part of the Auxiliary Area, timer Completion Flags and PVs, Index  
Registers, and the Data Registers will be saved.  
Memory retention  
during power  
interruptions  
FINS commands can be sent to a computer connected via the Host Link System by executing Network Communications Instructions from  
the PLC.  
Sending commands to  
a Host Link computer  
Host Link communications can be used for remote programming and remote monitoring through a Controller Link System or Ethernet  
network.  
Remote programming  
and monitoring  
8-level  
communications *2  
Remote programming and monitoring across up to eight network layers (Controller Link or Ethernet) by using Host Link. (They are possible  
between different types of networks.)  
Storing comments in  
CPU Unit  
I/O comments can be stored in the CPU Unit in Memory Cards *1 or EM file memory.  
Program checks are performed at the beginning of operation for items such as no END instruction and instruction errors.  
Programming Devices (except for the Programming Consoles) can also be used to check programs.  
Program check  
RUN output: The internal contacts will be ON (closed) while the CPU Unit is operating in RUN mode or MONITOR mode.  
These terminals are provided only on C200HW-PA204R, C200HW-PA209R, and CS1D-PA207R Power Supply Units.  
Control output signals  
Battery service life  
The battery life is 5 years at an ambient temperature of 25°C, although the lifetime can be as short as 1.1 years under adverse temperature  
and power conditions. (Battery Set: CS1W-BAT01) *3 *4  
CPU errors (watchdog timer), I/O verification errors, I/O bus errors, memory errors, and battery errors.  
Self-diagnostics  
Other functions  
Words in the Auxiliary Area store the number of power interruptions, time of the last power interruption, and total power ON time.  
*1. CPU Units with unit version 3.0 or later only.  
*2. CPU Units with unit version 2.0 or later only. (Communications across three network layers is supported for Pre-Ver. 2.0 CPU Units.)  
*3. CPU Units with unit version 3.0 or later only or Serial Communications Board/Unit with unit version 1.2 or later only.  
*4. Use a replacement battery that was manufactured within the last two years.  
*5. Serial Communications Board/Unit with unit version 1.3 or later only.  
Programmable Controllers SYSMAC CS1G/H  
13  
Functions Added by Unit Version  
The following functions have been added for the unit versions of CS1G/H CPU Units.  
OK: Supported, ---: Not supported  
Model  
CS1@-CPU@@H  
Unit version 2.0 Unit version 3.0  
Function  
Unit version  
No unit version  
Unit version 4.0  
Downloading and Uploading Individual Tasks  
Improved Read Protection Using Passwords  
---  
---  
OK  
OK  
OK  
OK  
OK  
OK  
Write Protection from FINS Commands Sent to CPU Units via  
Networks  
---  
OK  
OK  
OK  
Online Network Connections without I/O Tables  
---  
---  
OK  
OK  
OK  
OK  
OK  
OK  
Communications through a Maximum of 8 Network Levels  
OK  
Connecting Online to PLCs via NS-series PTs  
OK  
OK  
OK  
(from lot number 030201)  
OK  
OK  
OK  
Setting First Slot Words  
OK  
OK  
OK  
(for up to 8 group)  
(for up to 64 group)  
(for up to 64 group)  
Automatic Transfers at Power ON without a Parameter File (.STD)  
---  
OK  
OK  
Automatic Detection of I/O Allocation Method for Automatic  
Transfer at Power ON  
---  
---  
---  
Operation Start/End Times  
MILH, MILR, MILC  
---  
---  
---  
---  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
= DT, <>DT, <DT, < = DT, >DT, > = DT  
BCMP2  
OK  
GRY  
OK  
OK  
OK  
(from lot number 030201)  
Support of  
new  
TPO  
---  
---  
---  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
OK  
instructions  
DSW, TKY, HKY, MTR, 7SEG  
EXPLT, EGATR, ESATR, ECHRD, ECHWR  
OK  
IORD/IOWR reading/writing to CPU Bus Units  
OK  
OK  
OK  
(from lot number 030418)  
PRV2  
---  
---  
---  
---  
---  
OK  
OK  
Function blocks (CX-Programmer Ver.5.0 or later)  
OK  
Serial Gateway (converting FINS commands to CompoWay/  
F commands at the built-in serial port)  
---  
---  
OK  
OK  
Comment memory (in internal flash memory)  
Expanded simple backup data  
---  
---  
---  
---  
OK  
OK  
OK  
OK  
TXDU(256), RXDU(255) (support no-protocol communications with  
Serial Communications Units with unit version 1.2 or later)  
---  
---  
OK  
OK  
Model conversion instructions: XFERC(565), DISTC(566),  
COLLC(567), MOVBC(568), BCNTC(621)  
---  
---  
---  
---  
OK  
OK  
OK  
OK  
Special function block instructions: GETID(286)  
Additional  
instruction  
functions  
TXD(236), RXD(235) (support no-protocol  
communications with Serial Communications Units  
with unit version 1.2 or later)  
---  
---  
---  
---  
OK  
---  
OK  
OK  
Conversion instructions from numbers to ASCII  
and ASCII to numbers  
Use of new  
special  
instructions  
Flowchart conversion instructions (one type of  
block programming instructions) to convert  
flowchart programs from C-series Flowchart PLCs  
to ladder programs for CS/CJ-series PLCs  
---  
---  
---  
OK  
Online editing of function blocks  
---  
---  
---  
---  
---  
---  
OK  
OK  
Function  
block (FB)  
functional  
upgrades  
Support for I/O variables (including array variables  
for I/O variables)  
Support for STRING data type and processing  
functions for ST language.  
---  
---  
---  
OK  
Unit Versions  
Unit versions have been introduced to control differences in  
functions featured by CPU Units that are the result of version  
upgrades.  
Unit  
The unit version is marked on the nameplates of products subject  
to version control, as shown in the diagram.  
Unit version  
Unit Versions and Programming Devices  
Applicable PLCs  
Name  
CX-Programmer  
No unit version  
Version 2.1 or later  
Unit version 2.0  
Unit version 3.0  
Unit version 4.0  
Version 4.0 or later  
Version 5.0 or later  
Version 7.0 or later  
CS1H-CPU67H/66H/65H/64H/63H  
CS1G-CPU45H/44H/43H/42H  
CS1G/H-series  
14  
Programmable Controllers SYSMAC CS1G/H  
Current Consumption for Power Supply Units  
Checking Current Consumption and Power Consumption  
After selecting a Power Supply Unit based on considerations such as the power supply voltage, calculate the current and power  
requirements for each Rack.  
Condition 1: Current Requirements  
There are three voltage groups for internal power consumption: 5 V, 26 V, and 24 V.  
• Current consumption at 5 V (internal logic power supply)  
• Current consumption at 26 V (relay driving power supply)  
• Current consumption at 24 V (power supply output terminals) (C200HW-PA204S only)  
Condition 2: Power Requirements  
For each Rack, the upper limits are determined for the current and power that can be provided to the mounted Units. Design the system  
so that the total current consumption for all the mounted Units does not exceed the maximum total power or the maximum current  
supplied for the voltage groups shown in the following tables.  
CPU Racks and Expansion Racks  
The maximum current and total power supplied for CPU Racks and Expansion Racks according to the Power Supply Unit model are  
shown below.  
Note 1:For CPU Racks, include the CPU Backplane and CPU Unit current and power consumption in the calculations.  
2: For Expansion Racks, include the Expansion Backplanes current and power consumption in the calculations.  
Max. current supplied  
(D) Max. total  
power supplied  
Power Supply Units  
(A) 5 V  
(B) 26 V  
(C) 24 V  
C200HW-PA204C  
C200HW-PA204  
C200HW-PA204S  
C200HW-PA204R  
C200HW-PA209R  
C200HW-PD024  
C200HW-PD025  
CS1D-PA207R  
---  
---  
4.6 A  
4.6 A  
4.6 A  
4.6 A  
9 A  
0.6 A  
0.6 A  
0.6 A  
0.6 A  
1.3 A  
0.6 A  
1.3 A  
1.3 A  
0.56 A  
30 W  
30 W  
30 W  
30 W  
45 W  
30 W  
40 W  
35 W  
28 W  
0.8 A  
---  
---  
---  
4.6 A  
5.3 A  
7 A  
---  
---  
CS1D-PD024  
---  
4.3 A  
Conditions 1 and 2 below must be satisfied.  
Condition 1: Maximum Current  
(1) Total Unit current consumption at 5 V (A) value  
(2) Total Unit current consumption at 26 V (B) value  
(3) Current consumption for service power supply at 24 V (C) value (Only when using the service power supply from the  
C200HW-PA204S.)  
Condition 2: Maximum Power  
(1) x 5 V + (2) x 26 V + (3) x 24 V (D) value  
Example: Calculating Total Current and Power Consumption  
Example: When the Following Units are Mounted to a CS-series CPU Rack Using a CS1W-PA204S Power Supply Unit  
Voltage group  
Type  
Model  
Quantity  
5 V  
26 V  
24 V  
CPU Backplanes  
(8 slots)  
CS1W-BC083  
1
0.11 A  
---  
---  
CPU Unit  
CS1H-CPU67H  
CS1W-ID211  
CS1W-ID291  
CS1W-OC201  
CS1W-NC213  
CS1W-CLK23  
1
0.82 A  
0.10 A  
0.20 A  
0.10 A  
0.25 A  
0.33 A  
---  
---  
---  
---  
---  
2
Input Unit  
2
---  
---  
Output Unit  
2
0.048 A  
---  
---  
Special I/O Unit  
CPU Bus Unit  
1
1
---  
---  
---  
Service power supply  
0.3 A used  
---  
0.3 A  
0.11 A + 0.82 A + 0.10 A x 2 +  
0.20 A x 2 + 0.10 A x 2 +  
0.25 A + 0.33 A  
Total  
0.048 A x 2  
0.3 A  
Current consumption  
Power consumption  
Result  
Total  
2.31 A (4.6 A)  
0.096 A (0.6 A)  
0.3 A (0.8 A)  
2.31 A x 5 V=11.55 W  
0.096 A x 26 V=2.496 W  
0.3 A x 24 V=7.2 W  
Result  
11.55 + 2.496 + 7.2 = 21.246W (30W)  
Note: For details on Unit current consumption, refer to Ordering Information.  
Programmable Controllers SYSMAC CS1G/H  
15  
Using the CX-Programer to Display Current Consumption and Width  
CPU Rack and Expansion Rack current consumption and width can be displayed by selecting Current Consumption and Width from the  
Options Menu in the CS1 Table Window. If the capacity of the Power Supply Unit is exceeded, it will be displayed in red characters.  
Example:  
Current consumption  
at 5 V  
Power Supply  
Unit model  
Current  
Total current Long-distance  
Width  
consumption consumption  
at 26 V/24 V  
expansion  
16  
Programmable Controllers SYSMAC CS1G/H  
Ordering Information  
Basic Configuration Units ................................................................................18  
Programming Devices...................................................................................... 22  
Accessories and Maintenance Parts ...............................................................25  
DIN Track Mounting Accessories .....................................................................25  
Basic I/O Units .................................................................................................26  
Special I/O Units, CPU Bus Units, and Inner Boards ......................................32  
Replacing C200H I/O Units ..............................................................................54  
Ordering Information  
Low Voltage Directive  
Applicable Standard: EN61131-2  
Devices that operate at voltages from 50 to 1,000  
International Standards  
• The standards are abbreviated as follows: U: UL, U1:  
UL (Class I Division 2 Products for Hazardous  
VAC or 75 to 150 VDC must satisfy the appropriate  
Locations), C: CSA, UC: cULus, UC1: cULus (Class I  
safety requirements. With PLCs, this applies to  
Division 2 Products for Hazardous Locations), CU:  
Power Supply Units and I/O Units that operate in  
cUL, N: NK, L: Lloyd, and CE: EC Directives.  
these voltage ranges.  
• Contact your OMRON representative for further  
details and applicable conditions for these standards.  
These Units have been designed to conform to  
EN61131-2, which is the applicable standard for  
PLCs.  
EC Directives  
The EC Directives applicable to PLCs include the EMC  
Directives and the Low Voltage Directive. OMRON  
complies with these directives as described below  
manufacturing installations.  
EMC Directives  
Applicable Standards EMI: EN61000-6-4  
EN61131-2  
EMS: EN61000-6-2  
EN61131-2  
OMRON PLCs conform to the related EMC standards  
so that the devices and machines into which they are  
built can more easily conform to EMC standards. The  
actual PLCs have been checked for conformity to  
EMC standards. Whether these standards are  
satisfied for the actual system, however, must be  
checked by the customer.  
EMC-related performance will vary depending on the  
configuration, wiring, and other conditions of the  
equipment or control panel in which the PLC is  
installed.  
The customer must, therefore, perform final checks to  
confirm that the overall machine or device conforms  
to EMC standards.  
17  
Ordering Information  
Basic Configuration Units  
CPU Rack  
CS1 CPU Units  
Mountable Racks  
CS1D CPU  
Current  
consumption  
(A)  
Specifications  
CS1 CPU Rack  
Rack  
Product  
name  
Model  
Standards  
LD  
instruc-  
tion  
execu-  
tion time  
CS1D CPU  
Backplane  
CS1D-  
BC082S or  
CS1D-BC052  
Online  
Unit  
Duplex  
Commu- Power  
Duplex CS-series  
CPU  
CS/C200H-  
series CPU  
Backplane  
Numberof Program  
I/O points capacity  
Data memory  
capacity  
5 V  
26 V  
replace- nications Supply Backplane  
ment  
system system  
Units  
Units  
CS1W-BC@@  
2
CS1W-BC@@3  
448K words  
5,120  
*
0.82  
(DM: 32K words,  
EM: 32K words ×  
13 banks)  
(Expansion 250K steps  
Racks: 7)  
---  
---  
---  
---  
---  
---  
---  
---  
---  
CS1H-CPU67H  
CS1H-CPU66H  
CS1H-CPU65H  
CS1H-CPU64H  
CS1H-CPU63H  
CS1G-CPU45H  
CS1G-CPU44H  
CS1G-CPU43H  
CS1G-CPU42H  
256K words  
5,120  
*
(DM: 32K words,  
EM: 32K words ×  
7 banks)  
(Expansion 120K steps  
Racks: 7)  
0.82  
128K words  
5,120  
*
0.82  
(DM: 32K words,  
EM: 32K words ×  
3 banks)  
(Expansion 60K steps  
Racks: 7)  
0.02 µs  
No  
No  
No  
64K words  
5,120  
*
0.82  
(DM: 32K words,  
EM: 32K words ×  
1 bank)  
(Expansion 30K steps  
Racks: 7)  
CS1 CPU  
Units  
64K words  
5,120  
*
0.82  
(DM: 32K words,  
EM: 32K words ×  
1 bank)  
UC1, N,  
L, CE  
(Expansion 20K steps  
Racks: 7)  
Yes  
Yes  
No  
128K words  
5,120  
*
0.78  
(DM: 32K words,  
EM: 32K words ×  
3 banks)  
(Expansion 60K steps  
Racks: 7)  
64K words  
1,280  
*
0.78  
(DM: 32K words,  
EM: 32K words ×  
1 bank)  
(Expansion 30K steps  
Racks: 3)  
0.04 µs  
No  
No  
No  
64K words  
960  
*
0.78  
(DM: 32K words,  
EM: 32K words ×  
1 bank)  
(Expansion 20K steps  
Racks: 2)  
64K words  
960  
*
0.78  
(DM: 32K words,  
EM: 32K words ×  
1 bank)  
(Expansion 10K steps  
Racks: 2)  
*These values include the current consumption of a connected Programming Console. NT-AL001 Link Adapters consume an additional 0.15 A each when used.  
18  
Programmable Controllers SYSMAC CS1G/H  
Power Supply Units  
One Power Supply Unit is required for each Rack.  
Output capacity  
Options  
RUN  
output forecast  
monitor  
Mountable Racks  
CS1 Long-  
24-VDC  
0.8 A  
Power  
supply  
voltage  
5-VDCModel  
Standards  
output  
Mainte-  
nance  
C200HX/  
CPU HG/HE  
Rack Expansion sion  
I/O Rack Rack  
CS1  
CS1D  
Expan- BUS  
sion  
Rack  
SYSMAC  
Product  
name  
26-VDC  
output  
capacity  
Total  
CS1D  
Model  
Standards  
Expan-  
distance  
Expan-  
power con- service  
sumption  
CPU  
Rack  
Slave  
Rack  
power  
supply  
capacity  
sion Rack  
AC Power  
Supply  
Unit  
100 to 240  
VAC (wide  
range)  
UC1, N,  
L, CE  
Yes  
No  
C200HW-PA204C  
C200HW-PA204  
4.6 A  
0.625 A  
0.625 A  
30 W  
No  
U, C, N, L,  
CE  
No  
4.6 A  
4.6 A  
30 W  
30 W  
No  
Yes  
No  
No  
C200HW-PA204R U, C  
AC Power  
Supply  
Unit  
100 to 240  
VAC  
(wide  
0.625 A  
(with  
0.8 A,  
24 VDC  
service  
power  
range) *  
U, C, N, L,  
CE  
Yes  
No  
Yes  
Yes  
No  
C200HW-PA204S  
supply)  
100 to 120  
VAC or 200  
to 240 VAC  
U, C, N, L,  
CE  
9 A  
1.3 A  
45 W  
30 W  
No  
No  
Yes  
No  
No  
No  
C200HW-PA209R  
C200HW-PD024  
DC Power  
Supply  
Unit  
4.6 A  
0.625 A  
UC1, N,  
L, CE  
24 VDC  
5.3 A  
1.3 A  
40 W  
No  
No  
No  
C200HW-PD025  
*C200HW-PA204/PA204R Power Supply Units shipped before March 2010 have power supply voltage specifications of 100 to 120 VAC/200 to 240 VAC, 50/60 Hz.  
CS1 CPU Backplane  
Mountable configuration units  
Current  
consumption  
CPU Bus  
Units  
Basic I/O Units  
Special I/O Units  
(A)  
Appli-  
cable  
CPU  
Product name  
Specifications  
Model  
Standards  
C200H  
Group-2  
High-  
densityI/O Unit  
Unit  
C200H-  
series  
Basic  
C200H-  
series  
SpecialI/O  
Unit  
CS-series  
Basic I/O  
Unit  
CS-series  
SpecialI/O  
CS-series  
CPU Bus  
Unit  
Unit  
5 V  
26 V  
system system  
I/O Unit  
2 slots  
(Note:  
Expansion  
0.11  
---  
CS1W-BC022  
For CS-series  
Unit only  
Note: C200H-  
Racks cannot  
be connected.)  
Yes  
No  
Yes  
No  
Yes  
3 slots  
5 slots  
8 slots  
10 slots  
0.11  
0.11  
0.11  
0.11  
---  
---  
---  
---  
CS1W-BC032  
CS1W-BC052  
CS1W-BC082  
CS1W-BC102  
series Units  
cannot be  
mounted.  
CS1  
CPU  
Unit  
U, C, N, L,  
CE  
CS1 CPU Backplane  
2 slots  
(Note:  
Expansion  
Racks cannot  
be connected.)  
0.11  
---  
CS1W-BC023  
For both CS/  
C200H-series  
Units  
Yes  
3 slots  
5 slots  
8 slots  
10 slots  
0.11  
0.11  
0.11  
0.11  
---  
---  
---  
---  
CS1W-BC033  
CS1W-BC053  
CS1W-BC083  
CS1W-BC103  
2 slots (CS1W-BC022/023): 198.5 x 157 (W x H)  
3 slots (CS1W-BC032/033): 260 x 132 (W x H)  
Dimensions (mm) 5 slots (CS1W-BC052/053): 330 x 132 (W x H)  
8 slots (CS1W-BC082/083): 435 x 132 (W x H)  
10 slots (CS1W-BC102/103): 505 x 132 (W x H)  
Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2).  
2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2).  
Programmable Controllers SYSMAC CS1G/H  
19  
Expansion Racks  
Select the Backplane, Power Supply Unit, and Expansion Cable. If the expansion length is more than 12 m, an I/O Interface Unit is also  
required.  
Expansion Backplanes  
Normal Expansion (Not Long-distance Expansion)  
Mountable configuration units  
Current  
consumption  
CPU Bus  
Units  
Basic I/O Units  
Special I/O Units  
(A)  
Product name  
Specifications  
Model  
Standards  
C200H  
Group-2  
High-  
density I/O Unit  
Unit  
C200H-  
series  
Basic I/O  
Unit  
C200H-  
series  
Special I/O  
Unit  
CS-series  
Basic I/O  
Unit  
CS-series  
Special I/O  
CS-series  
CPU Bus  
Unit  
5 V  
26 V  
system system  
3 slots  
5 slots  
8 slots  
10 slots  
0.23  
0.23  
0.23  
0.23  
---  
---  
---  
---  
CS1W-BI032  
CS1W-BI052  
CS1W-BI082  
CS1W-BI102  
For CS-series  
Unit only  
Note:C200H-  
No  
No  
No  
series Units  
cannot be  
mounted.  
U, C, N, L,  
CE  
CS1 Expansion  
Backplanes  
Yes  
Yes  
Yes  
3 slots  
5 slots  
8 slots  
10 slots  
0.23  
0.23  
0.23  
0.23  
---  
---  
---  
---  
CS1W-BI033  
CS1W-BI053  
CS1W-BI083  
CS1W-BI103  
For both CS/  
C200H-series  
Units  
Yes  
Yes  
Yes  
3 slots (CS1W-BCI032/033): 260 x 132 (W x H)  
5 slots (CS1W-BI052/053): 330 x 132 (W x H)  
8 slots (CS1W-BI082/083): 435 x 132 (W x H)  
10 slots (CS1W-BI102/103): 505 x 132 (W x H)  
Dimensions (mm)  
For C200H-series 3 slots  
Unit only  
Note:CS-series  
0.15  
0.15  
0.15  
0.15  
---  
---  
---  
---  
C200HW-BI031  
5 slots  
C200HW-BI051  
C200HX/HG/HE  
Expansion  
I/O Backplane  
U, C, N, L,  
CE  
No  
Yes  
Yes  
No  
Yes  
No  
Units  
cannot be  
8 slots  
C200HW-BI081-V1  
C200HW-BI101-V1  
10 slots  
mounted.  
3 slots (C200HW-BI031):  
5 slots (C200HW-BI051):  
8 slots (C200HW-BI081-V1): 364 x 132 (W x H)  
189 x 132 (W x H)  
259 x 132 (W x H)  
Dimensions (mm)  
10 slots (C200HW-BI101-V1): 434 x 132 (W x H)  
Long-distance Expansion  
Mountable configuration units  
Basic I/O Units Special I/O Units  
Current  
consumption  
(A)  
CPU Bus  
Units  
CPU Unit  
mounted  
to CPU  
Product name  
Specifications  
Model  
Standards  
C200H  
Group-2  
High-  
C200H-  
series  
Basic I/O  
Unit  
C200H-  
series  
Special  
I/O Unit  
CS-series  
Basic I/O  
Unit  
CS-series  
Special  
I/O Unit  
CS-series  
CPU Bus  
Unit  
Backplane  
5 V  
26 V  
system system  
density  
I/O Unit  
3 slots  
5 slots  
8 slots  
10 slots  
0.23  
0.23  
0.23  
0.23  
---  
---  
---  
---  
CS1W-BI032  
CS1W-BI052  
CS1W-BI082  
CS1W-BI102  
For CS-series  
Unit only  
Note:C200H-  
U, C, N,  
CE  
series Units  
cannot be  
mounted.  
CS1 Expansion  
Backplanes  
CS1 CPU  
Unit  
Yes  
No  
Yes  
No  
Yes *  
3 slots  
5 slots  
8 slots  
10 slots  
0.23  
0.23  
0.23  
0.23  
---  
---  
---  
---  
CS1W-BI033  
CS1W-BI053  
CS1W-BI083  
CS1W-BI103  
For both CS/  
C200H-series  
Units  
U, C, N, L,  
CE  
*CS-series CPU Bus Units can be mounted in a Long-distance Expansion Rack, but the I/O refreshing time is longer than it is when the CPU Bus Unit is mounted in  
the CPU Rack.  
Note 1: C200H-series Units cannot be mounted to CS-series Expansion Backplanes (CS1W-BI@@2).  
2: CS-series Units cannot be mounted to C200HX/HG/HE Expansion I/O Backplanes (C200HW-BI@@2).  
20  
Programmable Controllers SYSMAC CS1G/H  
I/O Control Unit (Required for long-distance expansion)  
The CS1W-IC102 I/O Control Unit is mounted to a CPU Backplane or CS1 Expansion Backplane when expanding more than 12 m. A  
CV500-CN@@2 Long-distance Expansion Connecting Cable is used to connect the I/O Control Unit to a CS1W-II102 I/O Interface Unit.  
Current  
Mountable backplanes  
consumption  
(A)  
Product name  
Specifications  
Model  
Standards  
CPU  
CS1 Expansion  
5 V  
26 V  
backplane Backplanes  
system system  
I/O Control Unit  
Required to expand more than 12 m.  
(Two CV500-TER01 Terminators are included.)  
Connecting cable: Connecting Cable for Long-distance  
Expansion CV500-CN@@2  
U, C, N, L,  
CE  
---  
CS1W-IC102  
Yes  
Yes  
0.92  
Connecting unit: Interface Unit CS1W-II102  
I/O Interface Unit (Required for long-distance expansion)  
The CS1W-II102 I/O Interface Unit is mounted to a CS1 Expansion Backplane and connected to a CV500-CN@@2 Long-distance  
Expansion Connecting Cable when expanding more than 12 m.  
Current  
consumption  
(A)  
Product name  
Specifications  
Model  
Standards  
5 V  
24 V  
system system  
I/O Interface Unit  
Required to expand more than 12 m.  
Mountable backplane: CS1 Expansion Backplanes  
Connecting cable: Connecting Cable for Long-distance Expansion  
CV500-CN@@2  
---  
CS1W-II102  
U, C, N, L, CE  
0.23  
Connecting Cables for Expansion Backplanes  
Product name  
Specifications  
Model  
Standards  
Cable length: 0.3 m  
Cable length: 0.7 m  
Cable length: 2 m  
Cable length: 3 m  
Cable length: 5 m  
Cable length: 10 m  
Cable length: 12 m  
Cable length: 0.3 m  
Cable length: 0.7 m  
Cable length: 2 m  
Cable length: 3 m  
Cable length: 5 m  
Cable length: 10 m  
Cable length: 12 m  
Cable length: 0.3 m  
Cable length: 0.7 m  
Cable length: 2 m  
Cable length: 5 m  
Cable length: 10 m  
CS1W-CN313  
CS1W-CN713  
CS1W-CN223  
CS1W-CN323  
CS1W-CN523  
CS1W-CN133  
CS1W-CN133-B2  
CS1W-CN311  
CS1W-CN711  
CS1W-CN221  
CS1W-CN321  
CS1W-CN521  
CS1W-CN131  
CS1W-CN131-B2  
C200H-CN311  
C200H-CN711  
C200H-CN221  
C200H-CN521  
C200H-CN131  
CS1 I/O Connecting  
Cables  
Connects a CPU Backplane or CS1 Expansion Backplane to a  
CS1 Expansion Backplane.  
N, L, CE  
CS1 to C200H I/O  
Connecting Cables  
Connects a CPU Backplane or CS1 Expansion Backplane to a  
C200HX/HG/HE Expansion I/O Backplane.  
N, L, CE  
C200H I/O Connecting  
Cables  
N, L, CE  
L, CE  
Connects a C200HX/HG/HE Expansion I/O Backplane to a  
C200HX/HG/HE Expansion I/O Backplane.  
Connecting Cables for Long-distance Expansion  
Product name  
Specifications  
Model  
CV500-CN312  
CV500-CN612  
CV500-CN122  
CV500-CN222  
CV500-CN322  
CV500-CN522  
CV500-CN132  
CV500-CN232  
CV500-CN332  
CV500-CN432  
CV500-CN532  
Standards  
Cable length: 0.3 m  
Cable length: 0.6 m  
Cable length: 1 m  
Cable length: 2 m  
Cable length: 3 m  
Cable length: 5 m  
Cable length: 10 m  
Cable length: 20 m  
Cable length: 30 m  
Cable length: 40 m  
Cable length: 50 m  
Connecting Cables for  
Long-distance  
Expansion  
Connects a Long-distance I/O Control Unit to an I/O Interface  
Unit.  
N, L, CE  
Reading the production number  
@ @ @ @  
Year (e.g., 1997=7)  
Month (1 to 9, X (10), Y (11), Z (12))  
Day (01 to 31)  
Programmable Controllers SYSMAC CS1G/H  
21  
Programming Devices  
Support Software  
Product name  
Specifications  
Model  
Standards  
Number of Model  
Standards licenses  
Media  
CXONE-AL01C-V4  
CXONE-AL01D-V4  
CXONE-AL03C-V4  
CXONE-AL03D-V4  
CXONE-AL10C-V4  
CXONE-AL10D-V4  
CXONE-AL30C-V4  
CXONE-AL30D-V4  
CXONE-AL50C-V4  
CXONE-AL50D-V4  
CD  
DVD  
CD  
1 license  
The CX-One is a comprehensive software package that  
integrates Support Software for OMRON PLCs and  
components.  
CX-One runs on the following OS.  
Windows 2000 (Service Pack 4 or higher), XP, Vista, or 7  
Note: Except for 64-bit version.  
3 licenses  
10 licenses  
30 licenses  
50 licenses  
DVD  
CD  
FA Integrated Tool  
Package  
CX-One Ver.4.@  
---  
DVD  
CD  
CX-One Version 4.@ includes CX-Programmer Ver.9.@ and  
CX-Simulator Ver. 1.@.  
For details, refer to the CX-One catalog (Cat. No. R134).  
DVD  
CD  
DVD  
Note 1: Site licenses are available for users who will run CX-One on multiple computers. Ask your OMRON sales representative for details.  
2: Before ordering the software on a DVD, be sure that your computer and drive are compatible with the DVD format.  
Support Software in CX-One Ver.4.@  
The following tables lists the Support Software that can be installed from CX-One.  
Support Software in CX-One  
Outline  
Application software to create and debug programs for SYSMAC CS/CJ/CP/NSJ-series, C-series, and CVM1/C-series CPU  
Units, and to create and monitor data for SYSMAC CS/CJ-series Position Control Units.  
CX-Programmer  
Ver.9.@  
Application software to build and set up FA networks, such as Controller Link, DeviceNet, CompoNet, CompoWay/F, and Ethernet  
networks. The Routing Table Component and Data Link Component can be started from here. DeviceNet Configuration  
functionality is also included.  
CX-Integrator  
Ver.2.@  
Utility software that helps you to debug PLCs. It helps you to monitor the I/O status and to monitor/change present values within  
the PLC you specify.  
Switch Box Utility  
CX-Protocol  
Ver.1.@  
Ver.1.@  
Application software to create protocols (communications sequences) between SYSMAC CS/CJ/CP/NSJ-series or C200HX/HG/  
HE Serial Communications Boards/Units and general-purpose external devices.  
Application software to simulate SYSMAC CS/CJ/CP/NSJ-series CPU Unit operation on the computer to debug PLC programs  
without a CPU Unit.  
CX-Simulator  
CX-Position  
Ver.1.@  
Ver.2.@  
Ver.1.@  
Application software to create and monitor data for SYSMAC CS/CJ-series Position Control Units. (except for High-speed type)  
Application software to creat and monitor data for SYSMAC CS/CJ-series Position Control Units with MECHATROLINK-II *  
interface (NC@71).  
CX-Motion-NCF  
Application software to create data, and monitor program, and monitor data for SYSMAC CS/CJ-series Motion Control Units with  
MECHATROLINK-II * interface (MCH71).  
CX-Motion-MCH  
Ver.2.@  
Application software to create data for SYSMAC CS/CJ-series, C200HX/HG/HE, and CVM1/CV-series Motion Control Units, and  
to create and monitor motion control programs.  
CX-Motion  
Ver.2.@  
Ver.1.@  
Ver.5.@  
CX-Drive  
Application software to set and control data for Inverters and Servos.  
Application software to create and debug function block programs for SYSMAC CS/CJ-series Loop Controllers (Loop Control  
Units/Boards, Process Control CPU Units, and Loop Control CPU Units).  
CX-Process Tool  
Faceplate  
Auto-Builder for NS  
Application software that automatically outputs screen data as project files for NS-series PTs from tag information in function  
block programs created with the CX-Process Tool.  
Ver.3.@  
CX-Designer  
NV-Designer  
Ver.3.@  
Ver.1.@  
Application software to create screen data for NS-series PTs.  
Applications software to create screen data for NV-series small PTs.  
CX-Configurator  
FDT  
Ver.1.@  
Applications software to setting various units by installing its DTM module.  
CX-Thermo  
CX-FLnet  
Ver.4.@  
Ver.1.@  
Application software to set and control parameters in components such as Temperature Control Units.  
Application software for system setting and monitoring of SYSMAC CS/CJ-series FL-net Units.  
Network  
Configrator  
Ver.3.@  
Ver.4.@  
Application software for setting the tag datalink at the built-in EtherNet/IP port.  
Middleware necessary for CX-One applications to communicate with OMRON components, such, such as PLCs, Display  
Devices, and Temperature Control Units.  
CX-Server  
A group of components used with CX-One applications, such as the CX-Programmer and CX-Integrator. Includes the following:  
I/O tables, PLC memory, PLC Setup, Data Tracing/Time Chart Monitoring, PLC Error Logs, File Memory, PLC clock, Routing  
Tables, and Data Link Tables.  
PLC Tools  
(Installed automatically.)  
*MECHATROLINK II is a registered trademark of the MECHATROLINK Members Association.  
Note: If the complete CX-One package is installed, approximately 2.8 GB of Hard disk space will be required.  
22  
Programmable Controllers SYSMAC CS1G/H  
Connecting Cables for CX-One Components (e.g. CX-Programmer)  
Specifications  
Product name  
Model  
Standards  
Applicable  
computers  
Cable  
length  
Connection configuration  
Remarks  
IBM PC/AT or compatible computer + CS1W-CN226/626 +  
Peripheral port of CPU Unit  
CS1W-CN226  
2 m  
6 m  
Can be used  
for both  
peripheral bus  
and host link.  
Peripheral port  
RS-232C  
Peripheral Port  
CS1W-CN626  
Cables  
Connecting Cable  
CS1W-CN226/626  
Computer  
(9-pin RS-232C)  
between  
Programming  
Device  
(computer)  
and  
IBM PC/AT or  
compatible  
computer  
The following configuration can be used when using an  
RS-232C cable to connect to an IBM PC/AT or compatible  
computer.  
IBM PC/AT or compatible computer + XW2Z-200S-CV/V or  
XW2Z-500S-CV/V + Peripheral port of CPU Unit.  
Use when  
connecting to  
the peripheral  
port with a  
XW2Z-200S-  
CV/V or  
CE  
(D-Sub 9-pin)  
peripheral  
port  
CS1W-CN118  
0.1 m  
Peripheral port  
XW2Z-500S-  
CV/V  
RS-232C Cable  
XW2Z-200S-CV/V  
XW2Z-500S-CV/V  
RS-232C  
Cable.  
CS1W-CN118  
IBM PC/AT or compatible computer + XW2Z-200S-CV/V or  
XW2Z-500S-CV/V + RS-232C port of CPU Unit or Serial  
Communications Board/Unit  
Can be used  
for both  
peripheral bus  
and host link,  
and is  
equipped with  
an anti-static  
connector.  
XW2Z-200S-CV  
XW2Z-500S-CV  
XW2Z-200S-V  
XW2Z-500S-V  
2 m  
5 m  
2 m  
5 m  
Serial Communications Board's  
RS-232C ports  
RS-232C Cable  
Connecting Cables  
between Programming  
Device (computer) and  
RS-232C port  
XW2Z-200S-CV/V (2 m)  
XW2Z-500S-CV/V (5 m)  
Computer  
(9-pin RS-232C)  
CPU Unit's built-in  
RS-232C port  
IBM PC/AT or  
compatible  
computer  
Note: We recommend the following configuration if the  
CX-Programmer is always connected and you want to  
avoid switching to the other CPU Unit when an error  
occurs.  
---  
(D-Sub 9-pin)  
Can be used  
for host link  
only. Cannot  
be used for  
peripheral  
bus.  
Active CPU Unit  
Standby CPU Unit  
Terminator ON  
+5 V must be supplied to the  
NT-AL001 at computer side.  
DPL01  
DPL ST  
CTIVE  
CPU ST  
CTIVE  
CPU ST  
RUN  
A
TUS  
TUS  
TUS  
RUN  
ERR/ALM  
A
ERR/ALM  
L
A
INH BKUP  
PRPHL COMM  
INH BKUP  
PRPHL COMM  
A
R
A
LEFT CPU  
USE  
SYSMAC  
CS1D-CPU67H  
SYSMAC  
CS1D-CPU67H  
PROGRAMMABLE CONTROLLER  
P
R
O
G
R
A
M
M
A
B
L
E
C
O
N
T
R
O
L
L
E
R
N
O
U
S
E
RIGHT CPU  
USE  
MCPWR  
OPEN  
BUSY  
MCPWR  
OPEN  
BUSY  
N
O
U
S
E
DPL SW  
ON  
OFF  
S
P
L
D
P
L
A
C
T
.
A
C
T
.
L
E
F
T
R
I
G
H
T
ON  
INIT  
PERIPHERAL  
PERIPHERAL  
.
SW  
PRPHL  
COMM  
A39512  
RSV  
+5V  
PORT  
ON  
DUPLEX  
PORT  
RS-422A Adapter  
CJ1W-CIF11  
or NT-AL001  
NT-AL001  
RS-232C  
RS-422A/485  
RS-422A/485  
CX-Programmer  
IBM PC/AT or compatible computer +  
CS1W-CIF31 + CS1W-CN226/626 + Peripheral  
port of CPU Unit  
Can be used  
for both  
USB-Serial Conversion Cable  
CS1W-CIF31  
peripheral bus  
and host link.  
Serial Connecting Cable  
Computer  
USB port  
CS1W-CN226/626  
XW2Z-200S-CV/500S-CV  
XW2Z-200S-V/500S-V  
CQM1-CIF02  
Peripheral port or  
RS-232C port  
The USB  
Serial  
Conversion  
Cable  
connects to  
the serial  
connecting  
cable,  
Can be used  
for both  
peripheral bus  
and host link.  
IBM PC/AT or compatible computer +  
CS1W-CIF31 + XW2Z-200S-CV/500S-CV +  
CS1W-CN118 + Peripheral port of CPU Unit  
USB-Serial Conversion  
Cable (PC driver CD-ROM  
included)  
IBM PC/AT or  
compatible  
computer  
Can be used  
for host link  
only. Cannot  
be used for  
peripheral  
bus.  
CS1W-CIF31  
N
0.5 m  
IBM PC/AT or compatible computer +  
CS1W-CIF31 + XW2Z-200S-V/500S-V +  
CS1W-CN118 + Peripheral port of CPU Unit  
which  
(D-Sub 9-pin)  
connects to  
the PLC’s  
peripheral  
port or  
Conforms to USB 1.1  
Specifications.  
IBM PC/AT or compatible computer +  
CS1W-CIF31 + XW2Z-200S-CV/500S-CV +  
CS1W-CN118 + RS-232C port of CPU Unit or  
Serial Communications Board/Unit  
Can be used  
for both  
peripheral bus  
and host link.  
RS-232C  
port.  
Can be used  
for host link  
only. Cannot  
be used for  
peripheral  
bus.  
IBM PC/AT or compatible computer +  
CS1W-CIF31 + XW2Z-200S-V/500S-V + RS-232C  
port of CPU Unit or Serial Communications Board/  
Unit  
Programmable Controllers SYSMAC CS1G/H  
23  
Note: Either of the serial communications modes listed in the following table can be used to connect CX-One Support Software (e.g., the CX-Programmer) to a  
CS1-series PLC.  
Serial communications mode  
Peripheral bus  
Features  
This mode can provide high-speed communications, so this mode is normally used to connect when using CX-One component  
software such as the CX-Programmer.  
• Supports 1:1 connections only.  
• The Programming Device’s baud rate  
This is a general host computer communications protocol, which supports 1:1 and 1:N connections.  
• Host link operates at a slower speed than peripheral bus.  
• Host link supports 1:N connections as well as long-distance connections when RS-422A/RS-485 is used for a connection  
through a modem or optical adapter.  
Host Link (SYSWAY)  
Programming Console  
Cable model  
(Separate item)  
Product name  
Specifications  
Connection configuration  
Model  
Standards  
Can be connected  
to the CPU Unit’s  
peripheral port  
only. Cannot be  
connected to the  
RS-232C port.  
ACS1W-KS001-E  
Programming  
CS1W-CN224 (2 m)  
CS1W-CN624 (6 m)  
Programming Console  
Peripheral port  
CS1W-CN224: 2 m  
CS1W-CN624: 6 m  
C200H-PRO27-E  
U, C, N, CE  
Programming  
Console  
Key Sheet  
Programming  
Console  
C200H-PRO27  
Console Key  
Sheet is required  
(sold separately).  
CS1W-KS001  
Programming Console Key  
Sheet  
For the following Programming Consoles: C200H-PRO27  
For C200H-PRO27 connection, Cable length: 2 m  
CS1W-KS001-E  
CS1W-CN224  
Programming  
Console  
CE  
Connecting  
Cable  
For C200H-PRO27 connection, Cable length: 6 m  
CS1W-CN624  
Connecting Cables for NS-series PTs  
Specifications  
Product name  
Model  
Standards  
Connection configuration  
Cable length  
Connecting Cables between an NS-series PT and the RS-232C port of CPU Unit  
or Serial Communications Board/Unit  
XW2Z-200T  
2 m  
Serial  
Communications  
Board's  
NS-series PT  
Connecting Cables for  
NS-series PTs  
RS-232C  
---  
RS-232C Cable  
XW2Z-200T (2 m)  
XW2Z-500T (5 m)  
XW2Z-500T  
5 m  
CPU Unit's built-in  
RS-232C port  
XW2Z-200T-2  
XW2Z-500T-2  
2 m  
5 m  
Connecting Cables between an NS-series PT and the peripheral port of CPU Unit  
24  
Programmable Controllers SYSMAC CS1G/H  
Accessories and Maintenance Parts  
Product name  
Specifications  
Model  
Model  
Standards  
Flash Memory, 128 MB  
HMC-EF183  
HMC-AP001  
---  
Memory Cards  
Memory Card Adapter (Adapts to a computer’s PCMCIA card slot.)  
CE  
Product name  
Battery Set  
Specifications  
Standards  
Battery for CS-series maintenance  
Note 1: A battery is included with the CPU Unit as standard equipment.  
2: The battery life is 5 years at an ambient temperature of 25°C, although the  
lifetime can be as short as 1.1 years under adverse temperature and power  
conditions.  
CS1W-BAT01  
3: Use a replacement battery that was manufactured within the last two years.  
I/O Terminal Cover  
Cover for 10-pin Terminal Blocks  
C200H-COV11  
C200H-COV02  
C200H-COV03  
---  
Short-circuit protection for 10-pin Terminal Blocks (package of 10 covers); for 8 I/O  
points  
Terminal Block  
Cover  
Short-circuit protection for 19-pin Terminal Blocks (package of 10 covers); for 12 I/O  
points  
Protective cover for unused Power Supply Unit connector in C200H Backplane  
Protective cover for unused CS-series Unit connector in Backplane  
C500-COV01  
Connector Cover  
Space Units  
CV500-COV01  
For unused I/O slot spaces in the CS1W-BC@@3/BI@@3 or C200HW-BI@@@  
Backplanes  
C200H-SP001  
CS1W-SP001  
N, L  
---  
For unused I/O slot spaces in the CS1W-BC@@2/BI@@2 or CS1W-BC@@3/BI@@3  
Backplanes  
Backplane Insulation Plate  
(for C200HX/HG/HE  
Expansion I/O Backplane)  
10 slots  
C200HW-ATTA2  
C200HW-ATT82  
C200HW-ATT52  
C200HW-ATT32  
8 slots  
Used to electrically insulate the Backplane from the  
control panel as a noise countermeasure.  
N, L, CE  
5 slots  
3 slots  
24 VDC  
Contact relays  
G6B-1174P-FD-US-M DC24  
C200H-ATT01  
For Relay Output Unit C200H-OC221/222/223/224/225  
---  
Programming  
Console Mounting  
Bracket  
Use to mount a C200H-PRO27 Programming Console in a control panel.  
Connected to last Long-distance Expansion Rack (for CS1W-IC102). Two are  
included with the CS1W-IC102 I/O Control Unit.  
Terminator  
CV500-TER01  
U, C  
UC1, N, L,  
CE  
RS-422A Converter  
Converts RS-233C to RS-422A/RS-485.  
CJ1W-CIF11  
RS-232C/RS-422A Link  
Adapter  
RS-232C × 1 port  
RS-422A terminal block  
NT-AL001  
---  
DIN Track Mounting Accessories  
Product name  
Specifications  
Model  
Standards  
DIN Track  
1 set (package of 2 brackets)  
Mounting Bracket  
C200H-DIN01  
Track length: 50 cm  
Track length: 1 m  
Track length: 1 m  
Height: 7.3 mm  
Height: 7.3 mm  
Height: 16 mm  
PFP-50N  
DIN Track  
PFP-100N  
PFP-100N2  
---  
End Plate  
Spacer  
PFP-M  
PFP-S  
Note: Order in lots of 10.  
Programmable Controllers SYSMAC CS1G/H  
25  
Basic I/O Units  
CS1 Basic I/O Units  
Input Units  
Words  
required  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long-  
distance  
Expansion  
Rack  
Unit type Product name  
Specifications  
Model  
Standards  
SYSMAC (I/O bits:  
BUSSlave CIO 0000 to  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
Rack  
CIO 0319)  
system system  
@@3  
@@2  
@@3  
@@2  
24 VDC, 7 mA,  
16 inputs  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
1 word  
2 words  
4 words  
6 words  
0.10  
0.15  
0.15  
0.20  
---  
---  
---  
---  
CS1W-ID211  
CS1W-ID231  
CS1W-ID261  
CS1W-ID291  
DC Input Unit  
24 VDC, 6 mA,  
32 inputs  
UC1, N, L,  
CE  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
24 VDC, 7 mA,  
64 inputs  
24 VDC, approx.  
5 mA, 96 inputs  
U, C, N, L,  
CE  
CS1 Basic  
I/O Units  
100 to 120 VAC,  
AC Input Unit 16 inputs  
UC1, N, L,  
CE  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
1 word  
1 word  
0.11  
0.11  
---  
---  
CS1W-IA111  
CS1W-IA211  
100 to 120 VDC,  
16 inputs  
200 to 240 VAC,  
16 inputs  
UC, N, L,  
CE  
Output Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long-  
distance  
Expansion  
Rack  
Words  
required  
SYSMAC  
BUSSlave  
Rack  
Unit type Product name  
Specifications  
Model  
Standards  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
@@3  
@@2  
250 VAC or 120 VDC,  
2 A max.  
Independent contacts,  
8 outputs  
Relay Output  
Units  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
1 word  
1 word  
0.10  
0.13  
CS1W-OC201  
CS1W-OC211  
0.006  
per  
simulta-  
neously  
ON  
UC1, N, L,  
CE  
250 VAC or 120 VDC,  
2 A max.  
outputs  
Yes  
Yes  
Yes  
16 outputs  
12 to 24 VDC,  
0.5 A  
16 outputs  
UC1, N, L,  
CE  
Sinking  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
1 word  
1 word  
0.17  
0.17  
0.27  
0.27  
0.39  
0.39  
0.48  
---  
---  
---  
---  
---  
---  
---  
CS1W-OD211  
CS1W-OD212  
CS1W-OD231  
CS1W-OD232  
CS1W-OD261  
CS1W-OD262  
CS1W-OD291  
24 VDC, 0.5 A  
16 outputs  
U, C, N, L,  
CE  
Sourcing  
12 to 24 VDC,  
0.5 A  
32 outputs  
UC1, N, L,  
CE  
Sinking  
Sourcing  
Sinking  
Sourcing  
Sinking  
2 words  
2 words  
4 words  
4 words  
6 words  
Transistor  
Output Units  
24 VDC, 0.5 A  
32 outputs  
U, C, N, L,  
CE  
12 to 24 VDC,  
0.3 A  
64 outputs  
CS1 Basic  
I/O Units  
UC1, N, L,  
CE  
24 VDC, 0.3 A  
64 outputs  
12 to 24 VDC,  
0.1 A  
96 outputs  
U, C, N, L,  
CE  
12 to 24 VDC,  
0.1 A  
96 outputs  
Sourcing  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
6 words  
0.48  
---  
---  
CS1W-OD292  
CS1W-OA201  
0.23  
max.  
(0.07 +  
250 VAC, 2 A max.  
8 outputs  
1 word 0.02 ×  
Triac Output  
Units  
number  
of ON  
points)  
UC, N, L,  
CE  
0.406  
max.  
(0.07 +  
1 word 0.021 ×  
250 VAC, 0.5 A max.  
16 outputs  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
No  
---  
CS1W-OA211  
number  
of ON  
points)  
26  
Programmable Controllers SYSMAC CS1G/H  
I/O Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long-  
distance  
Expansion  
Rack  
Product  
name  
Words  
required  
SYSMAC  
BUSSlave  
Rack  
Unit type  
Specifications  
Model  
Standards  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
@@3  
@@2  
24 VDC, 6 mA  
32 inputs  
UC1, N, L,  
CE  
CS1W-MD261  
CS1W-MD262  
CS1W-MD291  
CS1W-MD292  
12 to 24 VDC, 0.3 A  
32 outputs  
Sourcing  
2 input  
words  
and 2  
output  
words  
DC Input/  
Transistor  
Output Unit  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
No  
0.27  
---  
24 VDC, 6 mA  
32 inputs  
24 VDC, 0.3 A  
32 outputs  
Sourcing  
24 VDC, approx. 5 mA  
48 inputs  
U, C, N, L,  
CE  
CS1 Basic  
I/O Units  
12 to 24 VDC, 0.1 A  
48 outputs  
Sinking  
3 input  
words  
and 3  
output  
words  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
No  
0.35  
---  
24 VDC, approx. 5 mA  
48 inputs  
12 to 24 VDC, 0.1 A  
48 outputs  
Sourcing  
TTL I/O Unit  
2 input  
words  
and 2  
output  
words  
5 VDC  
32 inputs, 32 outputs  
UC, N, L,  
CE  
Yes  
Yes  
No  
Yes  
Yes  
Yes  
No  
0.27  
---  
CS1W-MD561  
Note: The C200H-ID001 (8 no-voltage contact inputs, NPN) and C200H-ID002 (8 no-voltage contact inputs, PNP) cannot be used.  
Applicable Connectors  
Connector for CS1 Basic I/O Units (32 inputs, 64 inputs, 32 outputs, 64 outputs, 32 inputs/32 outputs)  
Name  
Connection  
Applicable Units  
FCN-361J040-AU Connector  
FCN-360C040-J2 Connector cover  
Model  
Standards  
C500-CE404  
Soldered  
(Included with Unit)  
C500-CE405  
Applicable  
Connectors  
FCN-363J040  
FCN-363J-AU  
Housing  
Contact  
---  
Crimped  
FCN-360C040-J2 Connector cover  
Pressure welded  
FCN-367J040-AU/F  
C500-CE403  
Connector for CS1 Basic I/O Units (96 inputs, 96 outputs, 48 inputs/48 outputs)  
Name  
Connection  
Applicable Units  
FCN-361J056-AU Connector  
FCN-360C056-J3 Connector cover  
Model  
Standards  
CS1W-CE561  
(Included with Unit)  
Soldered  
Applicable  
Connectors  
FCN-363J056  
FCN-363J-AU  
FCN-360C056-J3 Connector cover  
Housing  
Contact  
---  
Crimped  
CS1W-CE562  
CS1W-CE563  
Pressure welded  
FCN-367J056-AU  
Programmable Controllers SYSMAC CS1G/H  
27  
Interrupt Input Unit  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
CPU Rack  
Expansion  
Rack  
Input pulse  
width  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
distance BUS  
Product  
name  
Words  
required  
Input  
cur-  
rent  
External  
connec-  
tion  
Unit type  
Model  
Standards  
I/O  
Input  
points voltage  
CS1W-BC Expansion CS1W-BI Expansion Slave  
5 V  
26 V  
I/O Rack  
Rack  
Rack  
ON OFF  
time time  
system system  
@@3  
@@  
2
@@3 @@2  
Interrupt  
Input Unit  
Remov-  
able  
terminal  
block  
0.1 0.5  
7 mA ms ms  
*
*
*
Yes  
CS1 Basic  
I/O Units  
16  
24  
UC1, N, L,  
CE  
Yes Yes  
No  
Yes Yes  
No  
1 word  
0.10  
---  
CS1W-INT01  
inputs VDC  
max. max.  
*Interrupt inputs are not supported on these Racks (i.e., used as normal I/O Unit).  
Quick-response Input Unit  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Product  
name  
Words  
required  
Input Input pulse External  
Unit type  
Model  
Standards  
I/O  
Input  
Rack  
distance  
Expansion Slave  
Rack Rack  
BUS  
cur-  
width  
connec-  
tion  
points voltage  
Expansion  
I/O Rack  
rent (ON time)  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
@@3 @@2  
Quick-  
response  
Input Unit  
Remov-  
able  
terminal  
CS1 Basic  
I/O Units  
16  
24  
0.1 ms  
7 mA  
UC1, N, L,  
CE  
Yes Yes  
No  
Yes Yes  
Yes  
No  
1 word  
0.10  
---  
CS1W-IDP01  
inputs VDC  
max.  
block  
B7A Interface Unit  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long-  
distance  
Expansion  
Rack  
Product  
name  
SYSMAC  
BUSSlave  
Rack  
Unit type  
Specifications  
Words required  
Model  
Standards  
CS1W-BC  
@@3 @@2  
Yes Yes  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
Yes  
32 inputs  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
2 words  
2 words  
0.09  
0.09  
---  
---  
CS1W-B7A12  
CS1W-B7A02  
B7A Interface  
Unit  
32 outputs  
Yes  
Yes  
Yes  
1 input word  
and 1 output  
word  
CS1 Basic  
I/O Unit  
16 inputs/outputs  
32 inputs/outputs  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
0.09  
0.09  
---  
---  
CS1W-B7A21  
CS1W-B7A22  
UC1, CE  
2 input words  
and 2 output  
words  
Yes  
Yes  
Safety Relay Unit  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
C200HX/  
HG/HE  
Contact Number  
type  
CPU Rack  
Expansion CS1 Long- SYSMAC  
Product  
name  
Words  
required  
Power Number  
supply of input  
voltage words  
External  
connec-  
tions  
Unit type  
Model  
Standards  
Func-  
tion  
of  
Rack  
distance  
Expansion Slave  
Rack  
BUS  
Expan-  
CS1W-BC sion I/O  
Rack  
(Safety general  
output) inputs  
CS1W-BI  
5 V  
26 V  
Rack  
system system  
@@3  
@@2  
@@3 @@2  
Safety  
Relay Unit  
1 word  
or 2  
Remov-  
able  
termi-  
nal  
Emer-  
gency  
stop  
4
CS1Basic  
I/O Units  
24  
DPST- inputs/  
words  
VDC  
Yes Yes  
No  
Yes Yes  
Yes  
No  
1 word  
0.10  
---  
CS1W-SF200 U, C, CE  
NO  
com-  
mon  
(Shared  
Unit  
inputs)  
block  
28  
Programmable Controllers SYSMAC CS1G/H  
C200H Basic I/O Units and C200H Group-2 High-density I/O Units  
Input Units  
Words  
required  
Mountable Racks  
CS1 Expansion  
Current  
consumption  
(A)  
Product  
name  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long- SYSMAC (I/O bits:  
Unit type  
Specifications  
Model  
Standards  
Rack  
distance  
Expansion Slave  
Rack Rack  
BUS  
CIO 0000  
to CIO  
0319)  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
@@3  
@@2  
DC Input  
Unit  
U, C, N, L,  
CE  
12 to 24 VDC, 8 inputs  
24 VDC, 16 inputs  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
1 word  
1 word  
0.01  
0.01  
---  
---  
C200H-ID211  
C200H-ID212  
UC1, N, L,  
CE  
Yes  
No  
No  
No  
Yes  
100 to 120 VAC, 8 inputs  
100 to 120 VAC, 16 inputs  
100 to 120 VAC, 16 inputs  
200 to 240 VAC, 8 inputs  
200 to 240 VAC, 16 inputs  
200 to 240 VAC, 16 inputs  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
1 word  
1 word  
1 word  
1 word  
1 word  
1 word  
0.01  
0.01  
0.01  
0.01  
0.01  
0.01  
---  
---  
---  
---  
---  
---  
C200H-IA121  
C200H-IA122  
U, C, N, L  
AC Input  
Unit  
C200H  
Basic I/O  
Units  
C200H-IA122V CE  
C200H-IA221  
U, C, N, L  
C200H-IA222  
C200H-IA222V CE  
AC/DC Input  
Unit  
12 to 24 VAC/VDC, 8 inputs  
24 VAC/VDC, 16 inputs  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
1 word  
1 word  
0.01  
0.01  
---  
---  
C200H-IM211  
U, C, N, L,  
CE  
C200H-IM212  
DC Input  
Unit  
24 VDC, 32 inputs  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
2 words  
4 words  
2 words  
4 words  
0.10  
0.12  
0.10  
0.12  
---  
---  
---  
---  
C200H-ID216  
C200H-ID217  
C200H-ID218  
C200H-ID219  
C200H  
Group-2  
High-  
density  
I/O Units  
24 VDC, 64 inputs  
U, C, N, L,  
CE  
24 VDC, 32 inputs, 6 mA  
24 VDC, 64 inputs, 6 mA  
12 VDC, 64 inputs  
Yes  
No  
Yes  
Yes  
No  
No  
No  
4 words  
0.12  
---  
C200H-ID111  
U, C, N, L  
Programmable Controllers SYSMAC CS1G/H  
29  
Output Units  
Mountable Racks  
Current consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
Words  
Product  
Unit type  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
name  
required  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system  
system  
@@3  
@@2  
@@3  
@@2  
250 VAC or 24 VDC,  
2 A max.  
8 outputs  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
Yes  
1 word  
1 word  
0.01  
0.01  
C200H-OC221  
C200H-OC222  
0.075 per 8  
simultaneously  
ON outputs  
U, C, N, L  
250 VAC or 24 VDC,  
2 A max.  
12 outputs  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
250 VAC or 24 VDC,  
2 A max.  
12 outputs  
0.09 per 8  
1 word 0.008 simultaneously C200H-OC222N CE  
ON outputs  
250 VAC or 24 VDC,  
2 A max.  
16 outputs  
0.075 per 8  
Relay  
Contact  
Output Unit  
1 word  
1 word  
0.05 simultaneously C200H-OC225 UC1, N, L  
ON outputs  
250 VAC or 24 VDC,  
2 A max.  
0.09 per 8  
0.03 simultaneously C200H-OC226N CE  
16 outputs  
ON outputs  
250 VAC or 24 VDC,  
2 A max.  
Independent  
0.075 per 8  
0.01 simultaneously C200H-OC223  
ON outputs  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
1 word  
1 word  
1 word  
contacts: 5 outputs  
U, C, N, L  
250 VAC or 24 VDC,  
2 A max.  
Independent  
0.075 per 8  
0.01 simultaneously C200H-OC224  
ON outputs  
contacts: 8 outputs  
250 VAC or 24 VDC,  
2 A max.  
Independent  
0.09 per 8  
0.01 simultaneously C200H-OC224N CE  
ON outputs  
contacts: 8 outputs  
12 to 48 VDC, 1 A  
8 outputs  
Sinking  
C200H  
Basic I/O  
Units  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
1 word  
1 word  
1 word  
1 word  
1 word  
1 word  
0.14  
0.14  
---  
C200H-OD411  
C200H-OD213  
U, C, N, L,  
CE  
24 VDC, 2.1 A  
8 outputs  
Sinking  
---  
5 to 24 VDC, 0.3 A  
8 outputs  
Sourcing  
0.075 per 8  
0.01 simultaneously C200H-OD216 U, C, N, L  
ON outputs  
Transistor  
Output Unit  
24 VDC, 0.3 A  
12 outputs  
Sinking  
0.16  
---  
C200H-OD211  
5 to 24 VDC, 0.3 A  
12 outputs  
Sourcing  
0.075 per 8  
U, C, N, L,  
CE  
0.01 simultaneously C200H-OD217  
ON outputs  
24 VDC, 0.3 A  
16 outputs  
Sinking  
0.18  
0.16  
---  
---  
C200H-OD212  
24 VDC, 1 A  
16 outputs  
Sourcing  
Short-circuit  
protection  
Yes  
No  
Yes  
Yes  
No  
No  
Yes  
1 word  
C200H-OD21A CE  
C200H-OA223 CE  
Triac Output  
Unit  
250 VAC, 1.2 A max.  
8 outputs  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
Yes  
Yes  
No  
1 word  
1 word  
2 words  
0.18  
0.27  
0.27  
---  
---  
---  
250 VAC, 0.5 A max.  
12 outputs  
U, C, N, L,  
CE  
C200H-OA224  
C200H-OD218  
4.5 to 26.4 V,  
16 to 100 mA  
32 outputs  
Sinking  
U, C, N, L,  
CE  
Transistor  
Output Units  
C200H  
Group-2  
High-  
24 VDC, 0.5 A  
32 outputs  
Sourcing  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
2 words  
4 words  
0.48  
0.48  
---  
---  
C200H-OD21B U, C, CE  
density  
I/O Units  
Short-circuit  
protection  
4.5 to 26.4 V,  
16 to 100 mA  
64 outputs  
Sinking  
U, C, N, L,  
C200H-OD219  
CE  
30  
Programmable Controllers SYSMAC CS1G/H  
Interrupt Input Unit  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
CPU Rack  
Expansion  
Rack  
Input pulse  
width  
C200HX/  
HG/HE  
connection CS1W-BC Expansion CS1W-BI Expansion Slave  
CS1 Long- SYSMAC  
distance BUS  
Product  
name  
Words  
required  
Unit type  
Model  
Standards  
I/O  
Input Input  
External  
points voltage current  
5 V  
26 V  
I/O Rack  
Rack  
Rack  
ON OFF  
time time  
system system  
@@3 @@2  
@@3 @@2  
Interrupt  
Input Unit  
C200H  
Basic I/O  
Units  
12 to  
24  
VDC  
0.2 0.5 Removable  
*
Yes  
*
8
10  
mA  
ms  
ms terminal  
Yes No  
Yes No  
No  
No  
1 word 0.02  
---  
C200HS-INT01 U, C, CE  
inputs  
max. max. block  
*Interrupt inputs are not supported on these Racks (i.e., used as normal I/O Unit).  
Analog Timer Unit  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
distance BUS  
Expansion Slave  
Rack Rack  
Product  
name  
Words  
required  
Unit type  
Specifications  
Model  
Standards  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@2  
@@3  
@@2  
Analog  
Timer Unit  
C200H  
Basic I/O  
Units  
4-point timer  
Yes  
No  
Yes  
Yes  
No  
No  
Yes  
1 word  
0.06  
---  
C200H-TM001 U, C  
B7A Interface Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1 Expansion  
Rack  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
distance BUS  
Expansion Slave  
Rack Rack  
Product  
name  
Words  
required  
Unit type  
Specifications  
Model  
Standards  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
Yes  
@@2  
No  
@@3  
@@2  
C200H  
B7A  
16 inputs  
Yes  
Yes  
Yes  
No  
No  
Yes  
1 word  
1 word  
0.10  
0.10  
---  
---  
C200H-B7AI1  
C200H-B7AO1  
Basic I/O Interface  
U, C, CE  
16 outputs  
Yes  
No  
Yes  
No  
No  
Yes  
Units  
Units  
32 inputs  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
2 words  
2 words  
0.10  
0.10  
---  
---  
C200H-B7A12 U, C  
32 outputs  
C200H-B7A02  
1 input word  
and 1 output  
word  
16 inputs/outputs  
Yes  
No  
Yes  
Yes  
No  
No  
No  
0.10  
---  
C200H-B7A21  
C200H  
Group-2  
High-  
U, C, CE  
density  
I/O Units  
2 input words  
and 2 output  
words  
32 inputs/outputs  
Yes  
No  
Yes  
Yes  
No  
No  
No  
0.10  
---  
C200H-B7A22  
Programmable Controllers SYSMAC CS1G/H  
31  
Special I/O Units, CPU Bus Units, and Inner Boards  
CS1 Special I/O Units, CPU Bus Units, and Inner Boards  
Temperature Sensor Input Units (Process I/O Units)  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
CS1  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/ Expansion Long-  
SYSMAC  
BUS  
Slave  
Rack  
Unit  
type  
Product  
name  
Signal  
range  
selection  
Conver-  
HG/HE  
Expan-  
sion I/O  
Rack  
Rack  
dis-  
Model  
Standards  
I/O  
points  
Signal  
range  
External  
connection CS1W-BC  
sion  
tance  
Expan-  
sion  
CS1W-BI  
speed  
5 V  
26 V  
system system  
@@  
3
@@  
2
@@3 @@2  
Rack  
B, E, J, K,  
L, N, R, S, 20 ms/  
T, U, 4 inputs,  
WRe5-26, 10 ms/  
4
4
UC1, N,  
CE  
indepen-  
dent  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.12  
0.08 CS1W-PTS11  
inputs  
Isolated-  
PL II,  
2 inputs  
type Ther-  
mocouple  
Input Units  
100 mV  
4
4
R, S, K, J, 250 ms/  
indepen-  
dent  
Yes Yes  
Yes Yes  
Yes Yes  
No  
No  
No  
Yes Yes  
Yes Yes  
Yes Yes  
Yes  
Yes  
Yes  
No  
No  
No  
0.25  
0.18  
0.15  
---  
CS1W-PTS51  
inputs  
T, L, B  
4 inputs  
8
8
R, S, K, J, 250 ms/  
indepen-  
dent  
0.06 CS1W-PTS55 UC1, CE  
0.15 CS1W-PTS01-V1  
inputs  
T, L, B  
8 inputs  
4
B, E, J, K,  
indepen- N, R, S, T,  
4
150 ms/  
4 inputs  
inputs  
dent  
80mV  
Pt100 Ω  
20 ms/  
4 inputs, Removable  
10 ms/  
2 inputs  
CS1  
Special  
I/O  
4
(JIS, IEC),  
4
1 unit  
number’s  
words  
UC1, N,  
0.07 CS1W-PTS12  
CE  
Isolated-  
type  
Resistance  
Thermome-  
ter Input  
Units  
indepen- JPt100 Ω,  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.12  
inputs  
terminal  
block  
dent  
Pt50 Ω,  
Ni508.4 Ω  
Units  
4
Pt100 Ω  
indepen- (JIS, IEC),  
4
250 ms/  
4 inputs  
Yes Yes  
Yes Yes  
Yes Yes  
No  
No  
No  
Yes Yes  
Yes Yes  
Yes Yes  
Yes  
Yes  
Yes  
No  
No  
No  
0.25  
0.18  
0.15  
---  
CS1W-PTS52  
inputs  
dent  
JPt100 Ω  
8
Pt100 Ω  
8
250 ms/  
8 inputs  
indepen- (JIS, IEC),  
dent  
0.06 CS1W-PTS56  
0.15 CS1W-PTS02  
inputs  
JPt100 Ω  
4
Pt100 Ω  
4
100 ms/  
4 inputs  
indepen- (JIS, IEC),  
dent  
UC1, CE  
inputs  
JPt100 Ω  
Isolated-  
type  
Resistance  
Thermome-  
ter Input  
Unit  
4
4
100 ms/  
4 inputs  
indepen- Ni508.4 Ω  
dent  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.15  
0.15 CS1W-PTS03  
inputs  
(Ni508.4 W)  
32  
Programmable Controllers SYSMAC CS1G/H  
Analog Input Units  
Analog Input Units  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
CS1  
No. of  
unit  
numbers  
allocated  
C200HX/  
HG/HE  
Expan-  
sion I/O  
Rack  
Signal  
range  
points selec-  
tion  
CPU Rack  
CS1W-BC  
Expansion Long-  
SYSMAC  
Unit  
type  
Product  
name  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
Signal Resolu-  
Rack  
distance BUS  
Expan-  
sion  
range  
tion  
Slave  
Rack  
CS1W-BI  
speed  
tion  
5 V  
26 V  
systemsystem  
@@3  
@@2  
@@3 @@2  
Rack  
250 µs/  
1/8,000 input  
(Can (Can  
also be also be termi-  
set to  
1/4,000.) 1 ms/  
input.)  
1 to 5 V,  
0 to 5 V,  
0 to 10 V,  
-10 to  
10 V, 4 to  
20 mA  
Remov-  
able  
4
4
inputs  
pendent  
inde-  
Yes Yes  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.12  
0.12  
0.09 CS1W-AD041-V1  
0.09 CS1W-AD081-V1  
Analog  
Input  
Units  
set to  
nal  
block  
1 unit  
number’s  
words  
UC1, N,  
L, CE  
Remov-  
able  
termi-  
nal  
250 µs/  
1/8,000 input  
(Can  
also be also be  
set to  
1/4,000.) 1 ms/  
8
8
1 to 5 V,  
0 to 5 V,  
0 to 10 V,  
-10 to  
10 V, 4 to  
20 mA  
inde-  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
inputs  
pendent  
(Can  
CS1  
Special  
I/O  
block  
set to  
16  
16  
MIL  
2 unit  
Units  
inde-  
pendent  
connec- Yes Yes  
tor  
numbers’ 0.15  
words  
0.06 CS1W-AD161  
UC1, CE  
input.)  
inputs  
Connec-  
tor-  
Terminal  
Block  
Slim terminal block  
Terminal: 34, dimension: 128 x 40 x 39 mm  
XW2D-34G6  
Conver-  
sion Unit  
for  
CS1W-  
AD161  
---  
---  
Connection cable  
Cable length: 2 m  
XW2Z-200C  
Isolated-type DC Input Units (Process I/O Units)  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
unit  
numbers  
allocated  
C200HX/  
HG/HE  
Expan-  
CPU Rack  
CS1 Long- SYSMAC  
Unit  
type  
Product  
name  
Model  
Standards  
I/O  
points  
Signal  
range  
Conversion External  
speed  
distance  
Expansion Slave  
Rack Rack  
BUS  
connection  
CS1W-BC sion I/O  
CS1W-BI  
5 V  
26 V  
Rack  
systemsystem  
@@3 @@2  
@@3 @@2  
4 to 20 mA,  
0 to 20 mA,  
0 to 10 V,  
10 V,  
0 to 5 V,  
5 V,  
1 to 5 V,  
0 to 1.25 V,  
1.25 V  
20 ms/  
4 inputs,  
10 ms/  
4
UC1, N,  
CE  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.12  
0.12 CS1W-PDC11  
inputs  
2 inputs  
Isolated-  
type DC  
Input Units  
4 to 20 mA,  
0 to 10 V,  
inputs 0 to 5 V,  
1 to 5 V,  
8
250 ms/  
8 inputs  
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
0.18  
0.15  
0.06 CS1W-PDC55  
0.16 CS1W-PDC01  
4 to 20 mA,  
0 to 20 mA,  
1 to 5 V,  
0 to 5 V,  
5 V,  
0 to 10 V,  
10 V  
4
100 ms/  
4 inputs  
CS1  
Special  
I/O  
inputs  
Removable  
terminal  
block  
1 unit  
number’s  
words  
Units  
Isolated-  
type 2-Wire  
Transmitter  
Input Unit  
UC1, CE  
4
4 to 20 mA, 100 ms/  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.15  
0.16 CS1W-PTW01  
inputs 1 to 5 V  
4 inputs  
Power  
Transducer  
Input Unit  
8
0 to 1 mA,  
200 ms/  
8 inputs  
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
0.15  
0.15  
0.08 CS1W-PTR01  
0.08 CS1W-PTR02  
inputs 1 mA  
DC Analog  
Input Unit  
(100 mV)  
8
0 to 100 mV, 200 ms/  
inputs 100 mV 8 inputs  
Programmable Controllers SYSMAC CS1G/H  
33  
Analog Output Units  
Analog Output Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
Signal  
range  
points selec-  
tion  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
distance  
Unit Product  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
Signal Reso-  
BUS  
type  
name  
range  
lution  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
speed  
tion  
CS1W-BI  
5 V  
26 V  
Rack  
system system  
@@3  
@@  
2
@@3 @@2  
1 to 5 V,  
0 to 5 V,  
indepen- 0 to 10 V,  
4
4
1 ms/  
output  
UC1, N,  
L, CE  
1/4000  
1/4000  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.13  
0.18 CS1W-DA041  
Analog  
Output  
Units  
outputs  
dent  
-10 to 10 V,  
4 to 20 mA  
Remov-  
able  
termi-  
nal  
CS1  
1 unit  
number’s  
words  
Special  
I/O  
Units  
1 to 5 V,  
0 to 5 V,  
0 to 10 V,  
-10 to 10 V  
8
8
1 ms/  
output  
indepen-  
dent  
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
0.13  
0.13  
0.18 CS1W-DA08V  
0.25 CS1W-DA08C  
outputs  
block  
U, C, N, L,  
CE  
8
8
1 ms/  
output  
indepen- 4 to 20 mA 1/4000  
dent  
outputs  
Isolated-type Control Output Units (Process I/O Units)  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
Expansion  
CS1 Long- SYSMAC  
unit  
Signal  
range  
points selec-  
tion  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
Unit  
type  
Product  
name  
Conver- External  
sion connec-  
Model  
Standards  
Rack  
I/O  
Signal  
range  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
speed  
tion  
CS1W-BC  
@@ @@  
CS1W-BI  
5 V  
26 V  
system system  
3
2
@@  
3
@@2  
Isolated-  
type  
Control  
Output  
Units  
4
4
4 to  
20 mA,  
100 ms/  
outputs  
inde-  
Yes Yes  
No  
No  
Yes Yes  
Yes  
No  
0.15  
0.12  
0.16 CS1W-PMV01  
0.12 CS1W-PMV02  
outputs  
pendent 1 to 5V  
Remov-  
able  
termi-  
nal  
CS1  
1 unit  
number’s  
words  
Special  
I/O  
0 to 10V,  
UC1, CE  
10V,  
4
Units  
4
0 to 5V,  
inde-  
40 ms/  
outputs  
block  
Yes Yes  
Yes Yes  
Yes  
No  
outputs  
5V,  
0 to 1V,  
pendent  
1V  
Analog I/O Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
Expansion  
Rack  
Signal  
range  
points selec-  
tion  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
distance  
Unit  
type  
Product  
name  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
Signal Resolu-  
BUS  
range  
tion  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
speed  
tion  
CS1W-BC  
@@ @@  
CS1W-BI  
5 V  
26 V  
Rack  
system system  
3
2
@@3 @@2  
1 to 5V,  
0 to 5V,  
0 to 10V,  
-10 to 10V,  
4 to 20 mA  
4
inde-  
inputs pen-  
dent  
Analog  
I/OUnits  
4
1 ms/  
output  
1/4000  
1/4000  
Remov-  
able  
termi- Yes Yes  
nal  
block  
CS1  
Special  
I/O  
1 unit  
number’s  
words  
U, C, N, L,  
CE  
No  
Yes Yes  
Yes  
No  
0.20  
0.20 CS1W-MAD44  
4
inde-  
1 to 5V,  
0 to 5V,  
Units  
4
1 ms/  
output  
outputs pen-  
dent  
0 to 10V,  
-10 to 10V  
34  
Programmable Controllers SYSMAC CS1G/H  
Isolated-type Pulse Input Units (Process I/O Units)  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
Isolated-type  
Pulse Input Unit  
CS1  
Special  
1 unit  
number’s  
4 pulse inputs  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.20  
0.16 CS1W-PPS01  
UC1, CE  
I/O Units  
words  
Loop Control Board/Loop Control Unit  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
Expansion  
Rack  
Product  
name  
Unit type  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
Loop  
Control  
Board  
*2  
0.22  
50 blocks max. (total control  
blocks and operation blocks)  
---  
---  
CS1W-LCB01  
CS1W-LCB05  
*1  
*1  
CS1 Inner  
Board  
UC1, N,  
CE  
RDY  
EXEC  
Yes Yes  
No  
No  
No  
No  
---  
COM  
M
*2  
0.22  
500 blocks max. (total control  
blocks and operation blocks)  
PORT  
LCB01  
CX-Process Monitor  
Plus  
Ver.2.@  
1 license  
WS02-LCMC1-EV2  
OS:  
Monitoring Software for Loop Controller  
---  
Windows NT4.0, 2000, or XP  
3 licenses  
WS02-LCMC1-EV2L03  
*1. Mount a CS1W-LCB01/05 Loop Control Board in a CS1G/H-CPU@@H CPU Unit or a CS1D-CPU@@S CS1D Duplex System CPU Unit.  
*2. NT-AL001 Link Adapters consume an additional 0.15 A each when used.  
High-speed Counter Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
Unit  
type  
Product  
name  
Number Encoder A and B  
of count inputs, and Z pulse count  
channels input signal speed  
Maximum  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@  
2
@@3 @@2  
Input voltage: 5 VDC,  
12 VDC, or 24 VDC  
(only 1 axis for 5 V or  
12 V input)  
50 kHz  
High-speed  
Counter  
Units  
2
4
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
No  
0.36  
0.45  
---  
---  
CS1W-CT021  
CS1W-CT041  
CS1  
Special  
I/O Units  
4 unit  
numbers’  
words  
RS-422 line driver  
500 kHz  
50 kHz  
UC, N, L,  
CE  
Input voltage: 5 VDC,  
12 VDC, or 24 VDC  
(up to 2 axes for 5 V  
or 12 V input)  
Yes  
No  
RS-422 line driver  
500 kHz  
Programmable Controllers SYSMAC CS1G/H  
35  
Customizable Counter Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/  
Expansion CS1 Long- SYSMAC  
Unit type  
Product name  
Specifications  
Model  
Standards  
HG/HE  
Rack  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
@@ @@  
CS1W-BI  
5 V  
26 V  
system system  
3
2
@@3 @@2  
Two-axis pulse input  
Two-axis pulse output  
12 DC inputs  
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
No  
0.80  
0.75  
---  
CS1W-HCP22-V1  
8 transistor outputs  
Customizable  
Counter Units  
Single-axis pulse input  
1 analog input  
2 analog outputs  
12 DC inputs  
8 transistor outputs  
Yes  
No  
0.15 CS1W-HCA12-V1  
0.15 CS1W-HCA22-V1  
CS1  
Special  
I/O Units  
1 unit  
number’s  
words  
U, C, CE  
Two-axis pulse input  
2 analog outputs  
12 DC inputs  
Yes Yes  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
0.75  
0.60  
8 transistor outputs  
12 DC inputs  
8 transistor outputs  
---  
CS1W-HIO01-V1  
Position Control Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
Specifications  
No. of unit  
numbers  
allocated  
CPU Rack  
Expansion  
Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
distance BUS  
Expansion Slave  
Rack Rack  
Unit type  
Product name  
Model  
Standards  
CS1W-BC  
CS1W-BI  
Control output  
interface  
Number  
of axes  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
1 axis  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
No  
1 unit  
number’s  
words  
0.25  
0.25  
---  
---  
CS1W-NC113  
CS1W-NC213  
Pulse-train,  
2 axes Yes Yes  
4 axes Yes Yes  
Yes  
Yes  
No  
No  
open-collector  
outputs  
Position Control  
Units  
2 unit  
numbers’  
words  
No  
Yes Yes  
0.36  
---  
CS1W-NC413  
U, C, N, L,  
CE  
1 axis  
Yes Yes  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
1 unit  
number’s  
words  
0.25  
0.25  
---  
---  
CS1W-NC133  
CS1W-NC233  
2 axes Yes Yes  
4 axes Yes Yes  
Pulse-train, line-  
driver outputs  
2 unit  
numbers’  
words  
No  
Yes Yes  
Yes  
No  
0.36  
---  
CS1W-NC433  
For use with the CS1W-NC1@3 Number of axes supported: 1  
XW2B-20J6-1B  
XW2B-40J6-2B  
Relay Unit for  
Servo  
For use with the CS1W-NC2@3/  
Number of axes supported: 2  
NC4@3  
For use with the CS1W-NC@@3 Number of axes supported: 2, with communications support  
XW2B-40J6-4A  
XW2Z-050J-A6  
Connectable Servo Drive:  
OMNUC G5 Series, G Series, W  
Series, or SMARTSTEP 2  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
Cable length: 1 m  
XW2Z-100J-A6  
XW2Z-050J-A8  
XW2Z-100J-A8  
XW2Z-050J-A7  
XW2Z-100J-A7  
XW2Z-050J-A9  
XW2Z-100J-A9  
XW2Z-050J-A10  
XW2Z-100J-A10  
XW2Z-050J-A12  
XW2Z-100J-A12  
XW2Z-050J-A11  
XW2Z-100J-A11  
XW2Z-050J-A13  
XW2Z-100J-A13  
For use with the  
CS1W-NC113  
Number of axes  
supported: 1  
CS1  
Special  
I/O Units  
Connectable Servo Drive:  
SMARTSTEP Junior or A Series  
Open-collector  
output  
Connectable Servo Drive:  
OMNUC G5 Series, G Series, W  
Series, or SMARTSTEP 2  
For use with the  
CS1W-NC213/  
NC413  
Number of axes  
supported: 2  
---  
Connectable Servo Drive:  
SMARTSTEP Junior or A Series  
Servo Relay Unit  
Connecting  
Cable (Position  
Control Unit end)  
Connectable Servo Drive:  
OMNUC G5 Series, G Series, W  
Series, or SMARTSTEP 2  
For use with the  
CS1W-NC133  
Number of axes  
supported: 1  
Connectable Servo Drive:  
SMARTSTEP Junior or A Series  
Line-driver  
outputs  
Connectable Servo Drive:  
OMNUC G5 Series, G Series, W  
Series, or SMARTSTEP 2  
For use with the  
CS1W-NC233/  
NC433  
Number of axes  
supported: 2  
Connectable Servo Drive:  
SMARTSTEP Junior or A Series  
36  
Programmable Controllers SYSMAC CS1G/H  
Position Control Unit with MECHATROLINK-II interface  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Specifications  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Rack  
Unit  
type  
Product name  
Model  
Standards  
distance  
BUS  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
CS1W-BC  
CS1W-BI  
@@3 @@2  
Control output  
interface  
Number  
of axes  
5 V  
26 V  
Rack  
system system  
@@3 @@2  
Control commands  
are sent using  
MECHATROLINK-II  
communications.  
Direct operation  
from ladder  
Position Control  
Unit with  
MECHATROLINK-II  
interface  
2 axes  
CS1W-NC271  
CS1W-NC471  
1 unit  
number’s  
words  
4 axes  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.36  
---  
UC1, CE  
program.  
Control modes:  
Position control,  
speed control,  
and torque  
16 axes  
CS1W-NCF71  
FNY-NS115  
control  
MECHATROLINK-II To connect OMNUC W-series Servo Drive ( R88D-WT@) (Made by Yaskawa Corporation)  
Interface Unit The model number at the right is used to order from OMRON.  
CS1CPU  
Bus Unit  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 3 m  
Cable length: 5 m  
Cable length: 10 m  
Cable length: 20 m  
Cable length: 30 m  
FNY-W6003-A5  
FNY-W6003-01  
FNY-W6003-03  
FNY-W6003-05  
FNY-W6003-10  
FNY-W6003-20  
FNY-W6003-30  
MECHATROLINK-II To connect MECHATROLINK-II compliant devices (Made by Yaskawa Corporation)  
Cables The model numbers at the right are used to order from OMRON.  
---  
MECHATROLINK-II Terminating resistance for MECHATROLINK-II (Made by Yaskawa Corporation)  
FNY-W6022  
Terminator  
The model number at the right is used to order from OMRON.  
MECHATROLINK-II  
Repeater  
Communications repeater.  
FNY-REP2000  
Motion Control Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
Specifications  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product name  
Model  
Standards  
Rack  
distance  
Expansion Slave  
BUS  
Expansion  
CS1W-BC  
CS1W-BI  
@@3 @@2  
Control output Number  
5 V  
26 V  
I/O Rack  
Rack  
Rack  
interface  
of axes  
system system  
@@3 @@2  
Motion Control Unit  
(G-language  
programming)  
0.70  
(1.00 A  
when a  
Teaching  
Box is  
connected)  
5 unit  
numbers’  
words  
4 axes Yes Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
---  
---  
CS1W-MC421-V1  
CS1W-MC221-V1  
Analog outputs  
U, C, CE  
0.60  
(0.80 A  
when a  
Teaching  
Box is  
3 unit  
numbers’  
words  
2 axes Yes Yes  
Yes  
No  
CS1  
Special  
I/O  
connected)  
Units  
Teaching Box  
---  
---  
---  
---  
CVM1-PRO01-V1 CE  
Teaching Box  
Connecting Cable  
---  
Cable length: 2 m  
CV500-CN224  
L, CE  
ROM Cassette  
---  
For 2 axes  
---  
---  
---  
CVM1-MP702-V1 CE  
XW2B-20J6-6  
---  
MC Terminal Block  
Conversion Unit *  
For 4 axes  
XW2B-40J6-7  
---  
MC Terminal Block  
Conversion Unit  
Cable  
---  
---  
Cable length: 1 m  
XW2Z-100J-F1  
*Simplifies I/O connector wiring.  
Programmable Controllers SYSMAC CS1G/H  
37  
Motion Control Unit with MECHATROLINK-II interface  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Rack  
Unit type  
Product name  
Specifications  
Model  
Standards  
distance  
BUS  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
Rack  
system system  
@@3 @@2  
Motion Control  
Unit with  
MECHATROLINK-II  
interface  
For position, speed, and  
torque references via  
MECHATROLINK-II  
32 axes max. (physical axes:  
30 axes and virtual axes:  
2 axes)  
1 unit  
Yes Yes  
No  
Yes Yes  
Yes  
No  
number’s  
words  
0.80  
---  
CS1W-MCH71 UC1, CE  
Special motion control  
language  
MECHATROLINK-II To connect OMNUC W-series Servo Drive ( R88D-WT@) (Made by Yaskawa Corporation)  
Interface Unit The model number at the right is used to order from OMRON.  
FNY-NS115  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 3 m  
Cable length: 5 m  
Cable length: 10 m  
Cable length: 20 m  
Cable length: 30 m  
FNY-W6003-A5  
FNY-W6003-01  
FNY-W6003-03  
FNY-W6003-05  
FNY-W6003-10  
FNY-W6003-20  
FNY-W6003-30  
MECHATROLINK-II To connect MECHATROLINK-II compliant devices (Made by Yaskawa Corporation)  
Cables The model numbers at the right are used to order from OMRON.  
CS1 CPU  
Bus Unit  
MECHATROLINK-II Terminating resistance for MECHATROLINK-II (Made by Yaskawa Corporation)  
---  
FNY-W6022  
Terminator  
The model number at the right is used to order from OMRON.  
MECHATROLINK-II  
Repeater  
Required for more than 15 slave or 30 m.  
FNY-REP2000  
FNY-IO2310  
FNY-PL2900  
FNY-PL2910  
24-VDC I/O Module  
for  
MECHATROLINK-II  
64 inputs/outputs  
MECHATROLINK-II  
Counter Module  
Two reversible counters  
MECHATROLINK-II  
Pulse Output  
Module  
Pulse-string positioning on two channels  
38  
Programmable Controllers SYSMAC CS1G/H  
Serial Communications Boards/Serial Communications Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
Rack  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@2  
@@  
3
@@2  
Serial  
Communications  
Board  
Two  
RS-232C  
ports  
*5  
---  
CS1W-SCB21-V1  
CS1W-SCB41-V1  
0.28  
CS1  
Inner  
Board  
*4  
*4  
The following  
Yes Yes  
No  
No  
No  
No  
No  
---  
One  
communications  
protocols can be  
selected for each  
port: protocol  
RS-232C  
port and one  
RS-422A/  
485 port  
*5  
U, C, N, L,  
CE  
0.36  
---  
macro, host link,  
NT Link (1:N  
mode), serial  
gateway (*1), no Yes Yes  
protocol (* 2), or  
Modbus-RTU  
Serial  
Communications  
Unit  
Two  
RS-232C  
ports  
*5  
No  
No  
Yes Yes  
Yes Yes  
Yes  
Yes  
No  
No  
0.29  
---  
---  
CS1W-SCU21-V1  
CS1W-SCU31-V1  
CS1  
CPU  
Bus  
Unit  
1 unit  
number’s  
words  
Slave (*3).  
Two  
RS-422A/  
485 ports  
UC1, N, L,  
CE  
Yes Yes  
0.40  
*1. The serial gateway function is supported by Serial Communications Boards and Units with unit version 1.2 or later only.  
*2. The Serial Communications Unit’s no-protocol function is supported by Serial Communications Units with unit version 1.2 or later only. In addition the CPU Unit  
must be unit version 3.0 or later.  
*3. The Modbus-RTU Slave function is supported by Serial Communications Boards and Units with unit version 1.3 or later only.  
*4. One Board can be mounted in the Inner Board slot of the CPU Unit.  
*5. NT-AL001 Link Adapters consume an additional 0.15 A each when used.  
EtherNet/IP Unit  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product  
name  
Model  
Standards  
Communications Communications  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
cable  
functions  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
EtherNet/  
IP Unit  
CS1  
STP (shielded  
twisted-pair)  
cable of category message service  
5, 5e, or higher.  
*
*
*
*
*
Yes  
1 unit  
number’s  
words  
UC1, N,  
L, CE  
CPU  
Bus  
Unit  
Tag data link  
Yes Yes  
No  
Yes Yes  
No  
0.41  
---  
CS1W-EIP21  
*Up to eight CS1W-EIP21 EtherNet/IP Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one  
PLC.  
EtherNet Unit  
Mountable Racks  
Current  
CS1  
Expansion  
Rack  
consumption  
(A)  
No. of  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product  
name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
FINS communications  
service (TCP/IP and  
UDP/IP), FTP server  
EtherNet  
Unit  
CS1  
function, socket service,  
*
*
*
*
*
Yes  
1 unit  
number’s  
words  
ETN21  
CPU  
Bus  
Unit  
100BASE-TX mail send service, mail  
UC1, N, L,  
CE  
Yes Yes  
No  
Yes Yes  
No  
0.38  
---  
CS1W-ETN21  
Cable  
reception (remote  
command reception),  
auto-adjustment of PLC’s  
internal clock, and server  
host name specification  
*Up to four CS1W-ETN21 Ethernet Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.  
Programmable Controllers SYSMAC CS1G/H  
39  
Industrial Switching Hubs  
Specifications  
Functions  
Current  
Consumption  
(A)  
Product name  
Appearance  
Accessories  
Model  
Standards  
No. of  
pors  
Failure  
detection  
No  
No  
0.22  
0.22  
W4S1-03B  
W4S1-05B  
3
5
• Power supply  
connector  
UC, CE  
Quality of Service (QoS):  
EtherNet/IP control data priority  
Failure detection:  
Broadcast storm and LSI error detection  
10/100BASE-TX, Auto-Negotiation  
Industrial  
Switching Hubs  
• Power supply  
connector  
• Connector for  
informing error  
Yes  
0.22  
W4S1-05C  
CE  
5
Controller Link Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
*4  
Yes  
*4  
Yes  
*4  
Yes  
*4  
Yes  
Wired shielded  
twisted-pair cable *1  
No  
No  
No  
Yes  
No  
0.33  
0.52  
0.65  
---  
---  
---  
CS1W-CLK23  
CS1W-CLK13  
*4  
Yes  
*4  
Yes  
*4  
Yes  
*4  
Yes  
1 unit  
number’s  
words  
Controller Link Optical ring H-PCF  
UC1, N, L,  
CE  
Yes  
Yes  
No  
No  
Unit  
cable *2  
CS1  
CPU  
Bus  
Unit  
*4  
Yes  
*4  
Yes  
*4  
Yes  
*4  
Yes  
Optical ring GI  
cable *3  
CS1W-CLK53  
• CD-ROM × 1 *5  
Controller  
Link Support cable *1  
Board  
Wired shielded twisted-pair  
• Installation Guide (W467) × 1  
• Communications Connector × 1  
3G8F7-CLK23-E  
---  
CE  
H-PCF optical model  
GI optical model  
• CD-ROM × 1 *5  
3G8F7-CLK13-E  
3G8F7-CLK53-E  
• Installation Guide (W467) × 1  
• Optical Fiber Cable Bracket × 1  
• Power Supply Connector × 1  
Controller Link Options  
Product name  
Specifications  
Model  
Standards  
---  
Relay Terminal Block for  
Wired Controller Link Unit  
Use for Wired Controller Link Units (set of 5).  
CJ1W-TB101  
CS1W-RPT01  
CS1W-RPT02  
CS1W-RPT03  
Controller Link Repeater  
Unit  
Wire-to-Wire Model  
These products are not mounted to the  
PLC. (They are installed individually on  
DIN Rail or with screws.)  
CS1W-RPT01  
PWR  
T/R1  
T/R2  
UC1, CE  
Wire-to-Optical (H-PCF) Model *2  
Wire-to-Optical (GI) Model *3  
SL1  
T
E
R
S
W
SW1  
ON  
TER SW  
1
BAUD  
RATE  
2
SL2  
DC24V  
INPUT  
*1. Use the following special cable for shielded, twisted-pair cable.  
ESVC0.5 × 2C-13262 (Bando Electric Wire: Japanese Company)  
ESNC0.5 × 2C-99-087B (Nihon Electric Wire & Cable Corporation: Japanese Company)  
ESPC 1P × 0.5 mm2 (Nagaoka Electric Wire Co., Ltd.: Japanese Company)  
Li2Y-FCY2 × 0.56qmm (Kromberg & Schubert, Komtec Department: German Company)  
1 × 2 × AWG-20PE+Tr.CUSN+PVC (Draka Cables Industrial: Spanish Company)  
#9207 (Belden: US Company)  
*2. When using wire-to-optical (H-PCF) cable, use a H-PCF cable (for both Controller Link and SYSMAC LINK) or a H-PCF optical fiber cable with connector.  
*3. When using wire-to-optical (GI) cable, use a GI optical cable (for Controller Link).  
*4.  
Up to four Pre-Ver. 1.2 Controller Link Units (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be mounted to the CS1  
CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.  
Up to eight Controller Link Units with unit version 1.2 or later (both CS1W-CLK21-V1 Wired Units and CS1W-CLK@2-V1 Optical Units combined) can be  
mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.  
*5. The CD-ROM contains the following software.  
Controller Link (PCI) Driver  
FinsGateway Version 2003 (PCI-CLK Edition)  
FinsGateway Version 3 (PCI-CLK Edition)  
Setup Diagnostic Utility  
C Library  
40  
Programmable Controllers SYSMAC CS1G/H  
H-PCF Cables (For Controller Link and SYSMAC LINK)  
Product name  
Application and construction  
Specifications  
Black  
Model  
10 m S3200-HCCB101  
50 m S3200-HCCB501  
100 m S3200-HCCB102  
500 m S3200-HCCB502  
1,000 m S3200-HCCB103  
10 m S3200-HCCO101  
50 m S3200-HCCO501  
100 m S3200-HCCO102  
500 m S3200-HCCO502  
Standards  
(1)  
(2)  
(3)  
(4)  
Black  
Black  
(5)  
(6)  
Black  
Two-core  
Controller Link  
SYSMAC LINK  
SYSBUS  
Black  
optical cable  
with tension  
member  
1. Optical fiber single-core cord  
2. Tension member (plastic-sheathed wire)  
3. Filler (plastic)  
4. Filler surrounding signal wires (plastic,  
yarn, or fiber)  
Optical Fiber Cable  
Orange  
Orange  
Orange  
Orange  
5. Holding tape (plastic)  
6. Heat-resistant PV sheath  
Orange 1,000 m S3200-HCCO103  
---  
Controller Link: CS1W-CLK13  
CS1W-CLK12-V1  
3G8F7-CLK13-E  
3G8F7-CLK12-EV1  
CS1W-RPT02  
SYSMAC LINK:CS1W-SLK11  
3G8F7-SLK11-E  
Half-lock  
Full-lock  
S3200-COCF2571  
Optical  
Connectors  
(Crimp-cut)  
C200HW-SLK13/14  
Controller Link: CS1W-CLK13  
CS1W-CLK12-V1  
3G8F7-CLK13-E  
3G8F7-CLK12-EV1  
CS1W-RPT02  
S3200-COCF2071*  
SYSMAC LINK:3G8F7-SLK11-E  
*Full-lock Optical Connectors (Crimp-cut) (S3200-COCF2071) cannot be used with the CS1W-SLK11. Use a Half-lock Cable (S3200-COCF2571) or a H-PCF Optical  
Fiber Cable with Connectors (S3200-CN@@@-@@-@@).  
Programmable Controllers SYSMAC CS1G/H  
41  
H-PCF Optical Fiber Cables with Connectors (Black Composite Cables with Two-Optical Lines and Two Power Supply  
Lines)  
Applicable  
Appearance  
Model  
Standards  
S3200-CN@@@-20-20  
Controller Link  
SYSMAC LINK  
S3200-CN@@@-20-25  
S3200-CN@@@-25-25  
---  
Note: Optical connectors for H-PCF Optical Cables with Connectors are adhesive polished.  
• Cable Length  
• Optical Connector Assembly Tool  
The following cable lengths are available: 2 m, 5 m, 15 m, and  
20 m. For lengths of 21 m or more, contact your OMRON sales  
representative.  
Product  
name  
Applicable Units  
Model  
Maker  
Standards  
This tool is used on site  
for mounting crimp-cut  
connectors and hard  
plastic-clad silica optical  
fiber for optical  
Optical  
Fiber  
Sumitomo  
Electric  
Industries,  
Ltd.  
• Model Numbers  
CAK-0057  
---  
(1) 2 m, 5 m, 10 m, 15 m, 20 m  
(2) 21 m or longer  
(e.g.)  
Assembly transmission systems of  
Tool *  
SYSMAC C-series  
SYSBUS, SYSMAC  
LINK, and Controller  
Link.  
(e.g.)  
@@@  
S3200-CN -20-25  
S3200-CN-20-20  
(1)  
(2)  
(3)  
(1)  
(3) Specify the  
cable length  
in meters  
*
There is a risk of quality problems when using cables assembled by typical  
users, so we recommend purchasing cables with pre-attached connectors  
or having a qualified technician assemble the cables.  
(2) Cable length  
(1) H-PCF  
Optical Fiber Cable  
(3) Connectors (both ends)  
No.  
Connector lock  
@@@  
201  
501  
102  
152  
202  
Length  
2m  
5m  
20  
Full-lock  
Half-lock  
10m  
15m  
20m  
25  
Cable length  
GI Optical Cables  
A qualified technician must select, assemble, and install GI  
Optical Fiber Cable, so always let an optical cable specialist  
handle the GI cable.  
• 50/125 µm AGF Cables  
Items  
Minimum Typical Maximum  
Remarks  
Numerical  
Aperture (N.A)  
---  
---  
0.21  
---  
---  
---  
Usable Optical Fiber Cables and Optical Connectors  
• Optical fiber types: Graded, indexed, multi-mode, all quartz  
glass, fiber (GI-type AGF cable)  
3.0Lf  
0.5 km Lf  
Transmission  
loss (dB)  
λ = 0.8 µm,  
Ta = 25°C  
3.0 Lf + 0.2 0.2 km Lf 0.5 km  
3.0 Lf + 0.4 Lf 0.2 km  
• Optical fiber construction (core diameter/clad diameter):  
62.5/125 µm or 50/125 µm  
Connection  
loss (dB)  
---  
---  
---  
1.0  
λ = 0.8 µm, one location  
λ = 0.85 µm (LD)  
Transmission  
band width  
(MHz·km)  
• Optical fiber optical characteristics of optical fiber: Refer to the  
tables.  
500  
---  
Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak  
wavelength of the test light source.  
• Optical connectors: ST connectors (IEC-874-10)  
• 62.5/125 µm AGF Cables  
Items  
Minimum Typical Maximum  
Remarks  
---  
Numerical  
Aperture (N.A)  
---  
---  
0.28  
---  
---  
3.5Lf  
0.5 km Lf  
Transmission  
loss (dB)  
λ = 0.8 µm,  
Ta = 25°C  
3.5Lf + 0.2  
3.5Lf + 0.4  
0.2 km Lf 0.5 km  
Lf 0.2 km  
Connection  
loss (dB)  
---  
---  
---  
1.0  
λ = 0.8 µm, one location  
λ = 0.85 µm (LD)  
Transmission  
band width  
(MHz·km)  
200  
---  
Lf is Fiber length in km, Ta is ambient temperature, and λ is the peak  
wavelength of the test light source.  
42  
Programmable Controllers SYSMAC CS1G/H  
SYSMAC LINK Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
SYSMAC LINK  
Unit  
Coaxial  
(5C-2V cable)  
*1  
*1  
*1  
*1  
*1  
Yes  
No  
No  
No  
0.48  
0.47  
---  
---  
CS1W-SLK21  
CS1W-SLK11  
U, C, CE  
Yes Yes  
Yes Yes  
Data link and  
message  
communica-  
1 unit  
number’s  
words  
*1  
Yes Yes  
*1  
*1  
Yes Yes  
*1  
*1  
Yes  
Optical  
(H-PCF cable) *2  
U, C, N,  
CE  
tions functions  
No  
SYSMAC LINK  
Support Board  
Coaxial  
3G8F7-SLK21-E  
3G8F7-SLK11-E  
CS1  
CPU  
Bus  
Unit  
The 3G8F7-SLK@@ SYSMAC LINK Support Board includes the  
FinsGateway communications middleware version 3.  
---  
CE  
Optical (H-PCF cable) *2  
F Adapter  
---  
---  
C1000H-CE001  
C1000H-COV01  
N
One Adapter is included with each Coaxial-cable SYSMAC LINK  
Unit/Board.  
---  
---  
F Adapter  
Cover  
---  
Terminator  
A Terminator must be installed at each node on the ends of the  
network.  
---  
C1000H-TER01  
N
*1. Up to four CS1W-SLK11/21 SYSMAC LINK Units can be mounted to the CPU Backplane and Expansion Backplanes of one PLC.  
*2. When using wired optical (H-PCF) communications, use the H-PCF Cable or H-PCF Cable with pre-attached connectors.  
FL-net Units  
Mountable Racks  
Current  
CS1  
No. of  
unit  
numbers  
allocated  
consumption  
(A)  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Rack  
Unit  
type  
Product name  
FL-net Unit  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
Rack  
system system  
@@3 @@2  
CS1  
FL-net (OPCN-2) Ver. 2  
specifications  
100BASE-TX Cable  
*
*
*
*
*
Yes  
1 unit  
number’s  
words  
CPU  
Bus  
Unit  
Yes Yes  
No  
Yes Yes  
No  
0.38  
---  
CS1W-FLN22  
UC1, CE  
*Up to four CS1W-FLN22 FL-net Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.  
Programmable Controllers SYSMAC CS1G/H  
43  
DeviceNet Unit  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
CPU Rack  
CS1W-BC  
Unit  
type  
Product  
name  
Communications  
functions  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
CS1W-BI  
@@ @@2  
5 V  
26 V  
system system  
@@  
3
@@  
2
3
• Remote I/O  
Master  
communications  
(Fixed or user-set  
allocation)  
• Remote I/O Slave  
communications  
(Fixed or user-set  
allocation)  
DeviceNet  
Unit  
Functions as  
master and/or  
slave; allows  
control of  
32,000 points  
max. per  
Yes Yes  
No  
Yes  
Yes  
Yes  
No  
CS1  
1 unit  
number’s  
words  
CPU  
Bus  
Unit  
UC1, N, L,  
CE  
0.29  
---  
CS1W-DRM21-V1  
master.  
Maximum number of Units: 16 if Configurator is used  
• Message  
communications  
CompoNet Master Unit  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
Maximum  
Communications number of I/O  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
Expansion  
Rack  
Unit  
type  
Product  
name  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
functions  
points per  
Master  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
Word Slave  
Units:  
1,024 inputs  
and 1,024  
outputs  
(2,048 I/O  
points total)  
Bit Slave Units:  
256 inputs  
and 256  
CompoNet  
Master Unit  
1, 2, 4, or  
8 unit  
numbers’  
words  
(variable)  
• Remote I/O  
communications  
• Message  
CS1  
Special  
I/O Unit  
U, U1, L,  
N, CE  
Yes Yes  
No  
Yes  
Yes  
Yes  
No  
0.40  
---  
CS1W-CRM21  
communications  
outputs (512  
I/O points  
total)  
CompoBus/S Master Unit  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
Maximum  
Communications number of I/O  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
CPU Rack  
Unit  
type  
Product  
name  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
functions  
points per  
Master  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
CompoBus/  
S Master  
Unit  
256 max.  
(128 inputs and  
128 outputs)  
2 unit  
numbers’  
words  
CS1  
Special  
I/O Unit  
Remote I/O  
communications  
Yes Yes  
No  
Yes  
Yes  
Yes  
No  
0.15  
---  
CS1W-SRM21  
UC, CE  
128 max.  
1 unit  
(64 inputs and  
64 outputs)  
number’s  
words  
ID Sensor Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
Number  
of RW  
Heads  
External  
power  
supply  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product  
name  
Connecting  
ID System  
Model  
Standards  
Rack  
distance  
Expansion Slave  
BUS  
Expansion  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
I/O Rack  
Rack  
Rack  
system system  
@@3 @@2  
1 unit  
number’s  
words  
*
Not  
required  
1
2
1
2
Yes Yes  
Yes Yes  
Yes Yes  
Yes Yes  
No  
No  
No  
No  
Yes  
Yes  
Yes  
No  
0.26  
0.32  
0.26  
0.32  
0.13 CS1W-V680C11  
V680-series  
RFID system  
ID Sensor  
Units  
2 unit  
numbers’  
words  
24 VDC  
Yes Yes  
Yes  
Yes  
Yes  
No  
No  
No  
---  
CS1W-V680C12  
CS1  
Special  
I/O Unit  
UC, CE  
1 unit  
number’s  
words  
Not  
required  
Yes  
Yes  
0.12 CS1W-V600C11  
V600-series  
RFID system  
2 unit  
numbers’  
24 VDC  
Yes Yes  
---  
CS1W-V600C12  
words  
*The current consumption is 0.28 A when connected to the V680-H01. For details, refer to the V680 Series RFID System Catalog (Cat. No. Q151).  
44  
Programmable Controllers SYSMAC CS1G/H  
GP-IB Interface Unit  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit type Product name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
GP-IB  
Interface Unit  
CS1  
Special  
I/O Unit  
*
*
*
*
1 unit  
number’s  
words  
Master or slave mode  
provided.  
Yes Yes  
No  
Yes Yes  
Yes  
No  
0.33  
---  
CS1W-GPI01  
UC, CE  
*Up to four GP-IP Interface Units can be mounted to the CS1 CPU Backplane (CS1W-BC@@@) and CS1 Expansion Backplanes (CS1W-BI@@@) of one PLC.  
SYSMAC SPU (High-speed Data Storage Unit)  
Mountable Racks  
Current  
CS1  
Expansion  
Rack  
Specifications  
consumption  
(A)  
No. of  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
CS1W-BI  
Ethernet  
5 V  
26 V  
PC Card slot  
LAN port  
system system  
@@  
3
@@  
2
@@  
3
@@2  
SYSMAC SPU  
(High-speed  
Data Storage  
Unit)  
1 port  
(10/100  
BASE-TX)  
0.56  
0.70  
---  
---  
CS1W-SPU01-V2  
CS1W-SPU02-V2  
1 PC Card Type II  
slot Insert an  
OMRON  
HMC-EF@@@ to  
use the Memory  
Card.  
1 unit  
number’s  
words  
Yes Yes  
No  
Yes Yes  
Yes  
No  
UC1, CE  
2 ports  
(10/100  
BASE-TX)  
Functions: Setting the  
High-speed Data Storage Unit's  
unit settings, sampling settings,  
etc. (The software is required to  
make the High-speed Data  
Storage Unit's settings.)  
SPU-  
Console  
Support  
---  
---  
---  
WS02-SPTC1-V2  
WS02-EDMC1-V2  
---  
---  
Software  
*
CS1  
CPU  
Bus Unit  
OS: Windows 2000, XP, or Vista  
Functions: Automatically  
uploads collected data files from  
the SYSMAC SPU to the  
1 license  
SYSMAC  
SPU Data  
Management computer, and can also register  
Middleware the data in a database.  
OS: Windows 2000, XP, or Vista  
WS02-EDMC1-  
V2L05  
5 licenses  
Flash memory:  
128 MB  
---  
---  
---  
---  
---  
---  
---  
---  
HMC-EF183  
HMC-EF283  
HMC-EF583  
HMC-AP001  
Note:  
A memory  
Card is  
required to  
collect  
Memory  
Flash memory:  
256 MB  
Cards  
---  
Flash memory:  
512 MB  
data.  
Memory Card Adapter  
(for a computer’s PCMCIA slot)  
CE  
*SPU-Console version lower than version 2.0 cannot be connected to SYSMAC SPU Units with unit version 2.0 or later.  
Programmable Controllers SYSMAC CS1G/H  
45  
C200H Special I/O Units  
High-density Input Units (Special I/O Units)  
These Units function mainly like I/O Units, but are classified as Special I/O Units.  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
Expansion  
Rack  
No. of  
CPU Rack  
CS1W-BC  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
Unit type  
Product name  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@  
2
@@  
3
@@2  
24 VDC  
32 inputs  
DC Input Unit  
TTL Input Unit  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
No  
No  
Yes  
0.13  
0.13  
0.22  
0.22  
0.18  
---  
---  
---  
---  
---  
C200H-ID215  
C200H-ID501  
C200H-OD215  
C200H-OD501  
C200H-MD501  
5 VDC  
32 inputs  
No  
No  
No  
No  
Yes  
Yes  
Yes  
Yes  
Transistor  
Output Units  
24 VDC  
32 outputs Sinking  
C200HSpecial  
I/O Units  
U, C, N, L,  
CE  
TTL Output  
Units  
5 VDC  
32 inputs Sinking  
1 unit  
number’s  
words  
5 VDC  
16 inputs/outputs Sinking  
TTL I/O Unit  
DC Input/  
Transistor  
Output Units  
24 VDC  
16 inputs/outputs Sinking  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
0.18  
0.18  
---  
---  
C200H-MD215  
DC Input/  
Transistor  
Output Units  
12 VDC  
16 inputs/outputs Sinking  
C200H-MD115 U, C, N, L  
Connectors for High-density I/O Units Classified as Special I/O Units  
Product name  
Connection  
Part name  
FCN-361J024-AU Connector  
FCN-360C024-J2 Connector cover  
Model  
Standards  
C500-CE241  
(Provided with the Unit.)  
Soldered  
FCN-363J024  
FCN-363J-AU  
Housing  
Contact  
Applicable Connectors  
---  
Crimped  
C500-CE242  
FCN-360C024-J2 Connector cover  
Pressure welded  
FCN-367J024-AU/F  
C500-CE243  
Temperature Sensor Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
Signal  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product  
name  
Conver- External  
sion  
Model  
Standards  
I/O  
range Signal  
points selec- range  
tion  
Rack  
distance  
Expansion Slave  
Rack  
BUS  
connec-  
tion  
Expansion  
speed  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
I/O Rack  
Rack  
system system  
@@3 @@2  
4
Thermo-  
4
com- couple  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
0.45  
0.45  
---  
---  
C200H-TS001  
C200H-TS002  
inputs  
mon  
4
com- couple  
mon  
K, J  
Tempera-  
ture  
Sensor  
Units  
Thermo-  
4
No  
No  
Yes  
Yes  
4.8 s  
max.  
(when 4  
inputs  
are used  
per Unit)  
inputs  
Remov-  
able  
termi-  
nal  
block  
K, L  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
Ther-  
mome-  
ter  
U, C  
4
com-  
mon  
4
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
0.45  
0.45  
---  
---  
C200H-TS101  
C200H-TS102  
inputs  
JPt100  
Ther-  
mome-  
ter  
4
com-  
mon  
4
No  
Yes  
inputs  
Pt100  
46  
Programmable Controllers SYSMAC CS1G/H  
Analog Input Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
Sig-  
nal  
range  
selec-  
tion  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
Expansion  
Rack  
Unit Product  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
points  
Signal  
range  
Reso-  
lution  
distance  
Expansion Slave  
Rack Rack  
BUS  
type  
name  
Expansion  
I/O Rack  
speed  
tion  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
1 to 5 V,  
Analog  
Input  
Units  
8
com-  
mon  
2.5 ms/  
1/4000 input  
8
4 to 20 mA,  
0 to 10 V,  
-10 to 10 V  
Con-  
nector  
Yes No  
Yes  
Yes  
Yes No  
Yes No  
No  
Yes  
0.45  
0.10  
---  
C200H-AD002  
inputs  
max.  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
U, C, N, L,  
CE  
Remov-  
able  
termi- Yes No  
1 to 5 V,  
8
com-  
mon  
8
4 to 20 mA,  
0 to 10 V,  
-10 to 10 V  
1 ms/  
1/4000  
No  
Yes  
0.10 C200H-AD003  
inputs  
input  
nal  
block  
Analog Output Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
Expansion  
Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
Unit Product  
Signal  
range  
selection  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
points  
Signal  
range  
Resolu-  
tion  
distance  
Expansion Slave  
Rack Rack  
BUS  
type  
name  
speed  
tion  
CS1W-BC  
@@ @@  
CS1W-BI  
5 V  
26 V  
system system  
3
2
@@3 @@2  
Voltage  
4
inde-  
pendent 10 V  
4 to 20 mA,  
-10 to  
4
1/8190, 2.5 ms/  
Current output  
1/4095  
Analog  
Output  
Units  
Yes No  
Yes  
Yes No  
No  
Yes  
0.60  
---  
C200H-DA002  
outputs  
Remov  
able  
termi-  
nal  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
8
inde-  
1 to 5 V,  
0 to 10 V,  
U, C, N, L,  
8
1 ms/  
1/4000  
Yes No  
Yes No  
Yes  
Yes  
Yes No  
Yes No  
No  
No  
Yes  
Yes  
0.10  
0.10  
0.20 C200H-DA003 CE  
outputs  
output  
pendent -10 to 10 V  
block  
8
inde-  
pendent  
8
1 ms/  
output  
4 to 20 mA 1/4000  
0.25 C200H-DA004  
outputs  
Analog I/O Units  
Specifications  
Resolu-  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
C200HX/  
HG/HE  
Expansion  
I/O Rack  
CS1 Long- SYSMAC  
unit  
Unit Product  
Signal  
Conver- External  
sion connec-  
Model  
Standards  
I/O  
distance  
Expansion Slave  
Rack Rack  
BUS  
type  
name  
numbers  
allocated  
range Signal range  
points  
tion  
selection  
speed  
tion  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@  
2
@@3 @@2  
Analog  
I/O  
Units  
1 to 5 V,  
2 inde- 0 to 10 V,  
inputs pendent -10 to 10 V,  
2
1 ms/  
input  
1/4000  
1/4000  
Remov-  
able  
terminal  
block  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
4 to 20 mA  
U, C, N, L,  
CE  
Yes No  
Yes  
Yes No  
No  
Yes  
0.10  
0.20 C200H-MAD01  
1 to 5 V,  
2 inde- 0 to 10 V,  
outputs pendent -10 to 10 V,  
2
1 ms/  
output  
4 to 20 mA  
Programmable Controllers SYSMAC CS1G/H  
47  
Temperature Control Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
Unit  
type  
Product name  
Model  
Standards  
No. of Temperature  
loops sensor inputs  
distance  
Expansion Slave  
Rack Rack  
BUS  
Control output  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@  
2
@@3 @@2  
Thermocouples Open-collector  
2 loops (R, S, K, J, T, E, NPN outputs  
Yes No  
Yes No  
Yes No  
Yes  
Yes  
Yes  
Yes No  
Yes No  
Yes No  
No  
Yes  
0.33  
0.33  
0.33  
---  
---  
---  
C200H-TC001  
C200H-TC002  
C200H-TC003  
B, N, L, or U)  
(pulses)  
Thermocouples Voltage  
2 loops (R, S, K, J, T, E, outputs  
No  
No  
Yes  
Yes  
B, N, L, or U)  
(pulses)  
Thermocouples Current  
2 loops (R, S, K, J, T, E, outputs  
Temperature  
Control Units  
B, N, L, or U)  
(linear)  
1 unit  
number’s  
words  
Platinum  
resistance  
thermometers outputs  
(JPt00, Pt100) (pulses)  
ON/OFF  
transistor  
U, C, CE  
2 loops  
2 loops  
2 loops  
Yes No  
Yes No  
Yes No  
Yes  
Yes  
Yes  
Yes No  
Yes No  
Yes No  
No  
No  
No  
Yes  
Yes  
Yes  
0.33  
0.33  
0.33  
---  
---  
---  
C200H-TC101  
C200H-TC102  
C200H-TC103  
Platinum  
resistance  
thermometers outputs  
(JPt00, Pt100) (pulses)  
ON/OFF  
voltage  
C200H  
Special  
I/O Unit  
Platinum  
resistance  
thermometers outputs  
ON/OFF  
current  
(JPt00, Pt100) (linear)  
Data  
Setting  
Console  
Monitoring, setting, and changing  
present values, set points, alarm values,  
PID parameters, bank numbers, etc.  
---  
C200H-DSC01 U, C  
Cable length: 2 m  
Cable length: 4 m  
---  
---  
C200H-CN225  
N
C200H-CN425  
Connecting  
Cables  
48  
Programmable Controllers SYSMAC CS1G/H  
Heat/Cool Temperature Control Units  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack  
Expansion  
Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
Unit  
type  
Product name  
Model  
Standards  
No. of Temperature  
loops sensor inputs  
Control  
output  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
@@ @@  
CS1W-BI  
5 V  
26 V  
system system  
3
2
@@3 @@2  
Heating/  
cooling  
outputs:  
Open-collector  
NPN outputs  
(pulses)  
Thermocouples  
2 loops (R, S, K, J, T, E,  
B, N, L, or U)  
Yes No  
Yes  
Yes  
Yes No  
No  
Yes  
0.33  
0.33  
---  
---  
C200H-TV001  
Heating  
output:  
Voltage output  
Thermocouples (pulses),  
2 loops (R, S, K, J, T, E, Cooling  
Yes No  
Yes No  
No  
Yes  
C200H-TV002  
B, N, L, or U)  
output:  
Open-collector  
NPN outputs  
(pulses)  
Heating  
output:  
Current output  
Thermocouples (linear),  
2 loops (R, S, K, J, T, E, Cooling  
Yes No  
Yes No  
Yes No  
Yes  
Yes  
Yes  
Yes No  
Yes No  
Yes No  
No  
No  
No  
Yes  
Yes  
Yes  
0.33  
0.33  
0.33  
---  
---  
---  
C200H-TV003  
C200H-TV101  
C200H-TV102  
Heat/Cool  
Temperature  
Control Units  
B, N, L, or U)  
output:  
Open-collector  
NPN outputs  
(pulses)  
1 unit  
number’s  
words  
U, C, CE  
Heating/  
cooling  
outputs:  
Platinum  
resistance  
2 loops  
thermometers Open-collector  
(JPt00, Pt100) NPN outputs  
(pulses)  
C200H  
Special  
I/O Unit  
Heating  
output:  
Voltage output  
(pulses),  
Platinum  
resistance  
2 loops  
Cooling  
thermometers  
output:  
(JPt00, Pt100)  
Open-collector  
NPN outputs  
(pulses)  
Heating  
output:  
Current output  
(linear),  
Platinum  
resistance  
2 loops  
Cooling  
Yes No  
Yes  
Yes No  
No  
Yes  
0.33  
---  
C200H-TV103  
thermometers  
output:  
(JPt00, Pt100)  
Open-collector  
NPN outputs  
(pulses)  
Data  
Setting  
Console  
Monitoring, setting, and changing  
present values, set points, alarm values,  
PID parameters, bank numbers, etc.  
---  
C200H-DSC01 U, C  
Cable length: 2 m  
Cable length: 4 m  
---  
---  
C200H-CN225  
N
C200H-CN425  
Connecting  
Cables  
Programmable Controllers SYSMAC CS1G/H  
49  
PID Control Units  
Specifications  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
C200HX/  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Product name  
Model  
Standards  
No. of  
loops  
Temperature  
sensor input  
Control  
output  
HG/HE  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
CS1W-BI  
5 V  
26 V  
system system  
@@3  
@@  
2
@@3 @@2  
Voltage input/  
current input  
Open-  
collector  
2 loops (any of 4 to 20 mA, NPN  
Yes No  
Yes No  
Yes No  
Yes  
Yes  
Yes  
Yes No  
Yes No  
Yes No  
No  
Yes  
0.33  
0.33  
0.33  
---  
---  
---  
C200H-PID01  
1 to 5 V, 0 to 5 V,  
or 0 to 10 V)  
outputs  
(pulses)  
PID Control  
Units  
Voltage input/  
current input  
2 loops (4 to 20 mA,  
Voltage  
outputs  
(pulses)  
1 unit  
number’s  
words  
No  
No  
Yes  
Yes  
C200H-PID02 U, C, CE  
1 to 5 V, 0 to 5 V,  
or 0 to 10 V)  
Voltage input/  
current input  
2 loops (4 to 20 mA,  
Current  
outputs  
(linear)  
C200H  
Special  
I/O Unit  
C200H-PID03  
1 to 5 V, 0 to 5 V,  
or 0 to 10 V)  
Data  
Setting  
Console  
Monitoring, setting, and changing present  
values, set points, alarm values, PID  
parameters, bank numbers, etc.  
C200H-  
U, C  
---  
DSC01  
Cable length: 2 m  
Cable length: 4 m  
---  
---  
C200H-CN225  
N
C200H-CN425  
Connecting  
Cables  
High-speed Counter Units  
Mountable Racks  
Specifications  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
Unit  
type  
Number Encoder A and Maximum  
B input, pulse counting  
counters input, Z signal  
Product name  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
numbers  
allocated  
of  
Expansion  
I/O Rack  
speed  
CS1W-BI  
5 V  
26 V  
system system  
@@  
3
@@2  
@@3 @@2  
Voltage input:  
5, 12, or 24 VDC  
1
50 kHz  
75 kHz  
50 kHz  
75 kHz  
Yes No  
Yes No  
Yes  
Yes  
Yes No  
Yes No  
No  
Yes  
C200H-CT001-V1  
C200H-CT002  
0.30  
0.30  
---  
---  
1 unit  
number’s  
words  
High-speed  
Counter Units  
RS-422 line  
driver  
1
No  
No  
Yes  
Yes  
C200H  
Special  
I/O Unit  
U, C, CE  
Voltage input:  
12 or 24 VDC  
1 unit  
number’s  
words  
2
Yes No  
Yes  
Yes No  
C200H-CT021  
0.40  
---  
RS-422 line  
driver  
Cam Positioner Unit  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
Rack  
distance  
Expansion Slave  
Rack  
BUS  
Expansion  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
I/O Rack  
Rack  
system system  
@@3 @@2  
48 cam outputs (external outputs:  
16, internal outputs: 32)  
Control unit: 360 division per  
rotation  
Cam  
Positioner  
Unit  
1 unit  
Resolver response speed:  
800 r/min max.  
Yes  
No  
Yes  
Yes  
No  
No  
Yes  
number’s  
words  
0.30  
---  
C200H-CP114 U, C  
Resolver response time:  
200 µs (sampling frequency:  
5 KHz)  
C200H  
Special  
I/O Unit  
Data Setting  
Console  
Used to set cam data and monitor  
current cam angles.  
---  
C200H-DSC01 U, C  
---  
---  
---  
---  
Cable length: 2 m  
Cable length: 4 m  
C200H-CN225  
N
Connecting  
Cables  
C200H-CN425  
50  
Programmable Controllers SYSMAC CS1G/H  
Position Control Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
Specifications  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
CS1W-BC  
Expansion  
Rack  
Unit  
type  
Product name  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BI  
Controloutput Number  
5 V  
26 V  
interface  
of axes  
@@  
system system  
3
@@  
2
@@3 @@2  
Position Control Units  
1 axis Yes No  
2 axes Yes No  
Yes  
Yes  
Yes No  
No  
Yes  
1 unit  
number’s  
words  
0.30  
0.30  
---  
---  
C200HW-NC113  
C200HW-NC213  
Yes No  
No  
Yes  
Pulse-train,  
open-collector  
outputs  
U, C, CE  
2 unit  
numbers’  
words  
4 axes Yes No  
Yes  
Yes No  
No  
Yees  
0.50  
---  
---  
C200HW-NC413  
SYSMAC-NCT Position  
Control Unit Support  
Software  
Windows 95  
---  
---  
WS01-NCTF1-E  
CS1W-CN226  
Connection  
to  
peripheral  
port on  
Cable length: 2 m  
Cable length: 6 m  
IBM PC/AT or  
compatible  
---  
CS1W-CN626  
CPU Unit  
---  
Con-  
necting  
Cables  
XW2Z-200S-CV  
(NCT V1.11 or later)  
---  
---  
Cable length: 2 m  
Cable length: 5 m  
Connection  
to RS-232C IBM PC/AT or  
port on  
XW2Z-500S-CV  
(NCT V1.11 or later)  
C200H  
Special  
I/O Unit  
compatible  
CPU Unit  
---  
---  
Cable length: 2 m  
Cable length: 5 m  
XW2Z-200S  
XW2Z-500S  
*
*
For use with the  
C200HW-NC1@3  
Number of applicable axes: 1  
Number of applicable axes: 2  
XW2B-20J6-1B  
Relay Unit for Servo  
For use with the  
C200HW-NC2@3/  
NC4@3  
XW2B-40J6-2B  
Connected Servo Drive: OMNUC G  
Series, W Series, U Series, or  
SMARTSTEP 2  
Cable length: 0.5 m  
Cable length: 1 m  
XW2Z-050J-A6  
XW2Z-100J-A6  
For use with  
the C200HW-  
NC113  
Number of applicable  
axes: 1  
---  
Cable length: 0.5 m  
Cable length: 1 m  
Cable length: 0.5 m  
XW2Z-050J-A8  
XW2Z-100J-A8  
XW2Z-050J-A7  
Connected Servo Drive:  
SMARTSTEP Junior or A Series  
Servo Relay Unit  
Connecting Cables (to collector  
Position Control Unit) output  
Open-  
Connected Servo Drive: OMNUC G  
Series, W Series, U Series, or  
SMARTSTEP 2  
For use with  
the C200HW-  
NC213/  
Cable length: 1 m  
XW2Z-100J-A7  
Number of applicable  
axes: 2  
Cable length: 0.5 m  
Cable length: 1 m  
XW2Z-050J-A9  
XW2Z-100J-A9  
Connected Servo Drive:  
SMARTSTEP Junior or A Series  
NC413  
*If the computer has a D-sub 9-pin RS-232C connector, a commercially available 25 pin-to-9 pin adapter must be prepared separately.  
Example: D09-9F25F from Sanwa Supply  
Motion Control Units  
Mountable Racks  
Current  
CS1  
Specifications  
No. of  
unit  
numbers  
allocated  
consumption  
(A)  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product name  
Model  
Standards  
Rack  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
CS1W-BC  
CS1W-BI  
Control output Number  
5 V  
26 V  
I/O Rack  
interface  
of axes  
system system  
@@  
3
@@  
2
@@  
3
@@2  
Motion Control Units  
(G-language  
programming)  
0.65 (0.85  
A when a  
1 unit  
Analog output  
2 axes Yes  
No  
Yes  
Yes  
No  
No  
Yes  
number’s Teaching  
---  
C200H-MC221 U, C, CE  
CVM1-PRO01-V1 CE  
words  
Box is  
connected)  
C200H  
Special  
I/O Unit  
Teaching Box  
---  
---  
---  
Teaching Box  
Connecting Cable  
---  
---  
---  
---  
---  
Cable length: 2 m  
CV500-CN224  
L, CE  
ROM Cassette  
CVM1-MP702-V1 CE  
---  
MC Terminal Block  
Conversion Unit  
For 2 axes  
XW2B-20J6-6  
---  
MC Terminal Block  
Conversion Unit  
Cable  
---  
---  
Cable length: 1 m  
XW2Z-100J-F1  
Programmable Controllers SYSMAC CS1G/H  
51  
DeviceNet Master Unit  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
Expansion  
Rack  
Unit  
type  
Product  
name  
Communications  
functions  
Specifications  
Model  
Standards  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
Remote I/O  
Master  
communications  
(Fixed or  
user-set  
allocation)  
DeviceNet  
Master Unit  
Functions as;  
allows control  
of 4,800  
points max.  
per master.  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
U, C, N, L,  
CE  
Yes  
No  
Yes  
Yes  
No  
No  
No  
0.25  
---  
C200HW-DRM21-V1  
• Message  
communications  
CompoBus/S Master Unit  
Specifications  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
CPU Rack  
Expansion  
Rack  
Unit  
type  
Product  
name  
I/O capacity  
per Master  
Unit  
Model  
Standards  
Communications  
functions  
distance  
Expansion Slave  
Rack Rack  
BUS  
Expansion  
I/O Rack  
CS1W-BC  
CS1W-BI  
5 V  
26 V  
system system  
@@3 @@2  
@@3 @@2  
CompoBus/  
S Master  
Unit  
256 max.  
(128 inputs and  
128 outputs)  
2 unit  
numbers’  
words  
C200H  
Special  
I/O Unit  
Remote I/O  
communications  
U, C, N, L,  
CE  
Yes  
No  
Yes  
Yes  
No  
No  
No  
0.15  
---  
C200HW-SRM21-V1  
128 max.  
1 unit  
(64 inputs and  
64 outputs)  
number’s  
words  
ID Sensor Units  
Mountable Racks  
CS1  
Current  
consumption  
(A)  
No. of  
unit  
numbers  
allocated  
No. of  
connected  
R/W heads supply  
External  
power  
CPU Rack C200HX/  
HG/HE  
Expansion CS1 Long- SYSMAC  
Unit  
type  
Product  
name  
Connected ID  
Systems  
Model  
Standards  
Rack  
distance  
Expansion Slave  
Rack  
BUS  
Expansion  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
I/O Rack  
Rack  
system system  
@@3 @@2  
ID Sensor  
Units  
C200H  
Special  
I/O Unit  
1 unit  
number’s  
words  
RFID System  
V600 Series  
Not  
required  
1
Yes No  
Yes  
Yes No  
No  
Yes  
0.25  
0.12 C200H-IDS01-V1 U, C  
52  
Programmable Controllers SYSMAC CS1G/H  
ASCII Units  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
Expansion  
Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
distance  
Unit  
type  
Product name  
Specifications  
Model  
Standards  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
Rack  
system system  
@@3 @@2  
User memory area: 200 Kbytes  
Shared memory: Provided  
(general-purpose area: 90  
words)  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
Yes  
0.25  
0.30  
---  
---  
C200H-ASC11  
RS-232C x 2 ports  
ASCII Units  
200 Kbytes  
RAM  
RS-232C x 1 port +  
RS-422A/485 x 1 port  
1 unit  
number’s  
words  
U, C, CE  
No  
Yes  
C200H-ASC21  
C200H-ASC31  
C200H  
Special  
I/O Unit  
200 Kbytes  
RAM  
RS-232C x 2 ports +  
RS-232C x 1 port for Terminal  
Yes  
Yes  
No  
No  
Yes  
Yes  
Yes  
Yes  
No  
No  
No  
No  
Yes  
Yes  
0.30  
0.20  
---  
---  
24 Kbytes  
RAM  
RS-232C x 2 ports  
1 unit  
number’s  
words  
C200H-ASC02 N, CE  
Converts RS-232C to RS-422A/  
RS-485 format.  
RS-422A Adapter  
---  
---  
---  
---  
CJ1W-CIF11  
NT-AL001  
UC, N, CE  
RS-232C/RS-422A One RS-232C port  
Link Adapter One RS-422 terminal block  
---  
PC Link Unit  
Mountable Racks  
Current  
consumption  
(A)  
CS1  
No. of  
CPU Rack  
Expansion  
Rack  
C200HX/  
HG/HE  
CS1 Long- SYSMAC  
unit  
distance  
Unit  
Product name  
type  
Specifications  
Model  
Standards  
BUS  
numbers  
allocated  
Expansion  
I/O Rack  
Expansion Slave  
Rack  
CS1W-BC  
CS1W-BI  
@@3 @@2  
5 V  
26 V  
Rack  
system system  
@@3 @@2  
PC Link Unit  
C200H  
Special  
I/O Unit  
Up to 32 PLC Link Units for 1 level,  
16 PLC Link Units for multilevel  
systems  
1 unit  
number’s  
words  
Yes  
No  
Yes  
Yes  
No  
No  
Yes  
0.35  
---  
C200H-LK401 N, L, CE  
Programmable Controllers SYSMAC CS1G/H  
53  
Replacing C200H I/O Units  
This section shows the corresponding CS1 I/O models and notes for replacing C200H I/O Units.  
16-point DC Input Units  
64-point DC Input Units  
Corresponding  
CS1 I/O Unit  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-ID212  
Item  
C200H I/O Unit  
C200H-ID219  
Model number  
Description  
CS1W-ID211  
Model number  
CS1W-ID261  
16-point DC Input Units with terminal blocks  
The terminal arrangement must be changed.  
64-point DC Input Units with connectors. The connectors,  
the pin arrangement, and the input specifications are the  
same.  
Description  
Notes  
The impedance increases (from 3kΩ to 3.3kΩ). Check that  
correct operation is possible in cases where increased  
impedance may influence operation.  
There are 4 commons instead of 2. Connect where  
necessary.  
Notes  
The internal 5-V current consumption increases (from  
120mA to 150mA). Check that the increased current is  
within the range of the power supply.  
The internal 5-V current consumption increases (from  
10mA to 100mA). Check that the increased current is  
within the range of the power supply.  
64-point DC Input Units (cntd.)  
32-point DC Input Units  
Corresponding  
CS1 I/O Unit  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-ID217  
Item  
C200H I/O Unit  
C200H-ID218  
Model number  
CS1W-ID261  
Model number  
CS1W-ID231  
64-point DC Input Units with connectors. The connectors  
and the pin arrangement are the same. The input current  
increases, allowing use with a wider range of devices.  
32-point DC Input Units with connectors. The connectors,  
the pin arrangement, and the input specifications are the  
same.  
Description  
Description  
Notes  
There are 4 commons instead of 2. Connect where  
necessary.  
There are 2 commons instead of 1. Connect where  
necessary.  
The input specifications change (e.g., the impedance  
decreases and the input current increases from 4.1mA to  
6mA.) Check that correct operation is possible in cases  
where changes in input specifications may influence  
operation.  
The internal 5-V current consumption increases (from  
100mA to 150mA). Check that the increased current is  
within the range of the power supply.  
Notes  
32-point DC Input Units (cntd.)  
The internal 5-V current consumption increases (from  
100mA to 150mA). Check that the increased current is  
within the range of the power supply.  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-ID216  
Model number  
CS1W-ID231  
16-point Sinking Transistor Output Units  
32-point DC Input Units with connectors. The connectors  
and the pin arrangement are the same. The input current  
increases, allowing use with a wider range of devices.  
Description  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-OD212  
There are 2 commons instead of 1. Connect where  
necessary.  
Model number  
CS1W-OD211  
16-point Transistor Output (sinking) Units with terminal  
blocks. The output current capacity increases (from 0.3A  
per point and 4.8A per Unit to 0.5A per point and 8A per  
Unit). The rated voltage range also increases (from 24V to  
any voltage in the range 12 to 24V.)  
The input specifications change (e.g., the impedance  
decreases and the input current increases from 4.1mA to  
6mA.) Check that correct operation is possible in cases  
where changes in input specifications may influence  
operation.  
Description  
Notes  
The terminal arrangement must be changed.  
The internal 5-V current consumption increases (from  
100mA to 150mA). Check that the increased current is  
within the range of the power supply.  
The output specifications change. Check that correct  
operation is possible in cases where changes in output  
specifications may influence operation. (Residual voltage  
increases from 0.8V to 1.5V, ON response time increases  
from 0.1ms to 0.5ms, OFF response time increases from  
0.3ms to 1ms.)  
Notes  
54  
Programmable Controllers SYSMAC CS1G/H  
C200H???????????????????  
16-point Sourcing Transistor Output Units  
32-point Sourcing Transistor Output Units  
Corresponding  
CS1 I/O Unit  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-OD21A  
Item  
C200H I/O Unit  
C200H-OD21B  
Model number  
Description  
CS1W-OD212  
Model number  
CS1W-OD232  
16-point Transistor Output (sourcing) Units with terminal  
blocks.  
32-point Transistor Output (sourcing) Units with  
connectors. The connectors and the pin arrangement are  
the same.  
Description  
The terminal arrangement must be changed.  
There are 2 commons instead of 1. Connect where  
necessary.  
The output capacity changes (from 1A per point and 4A  
per Unit to 0.5A per point and 5A per Unit). Check that  
correct operation is possible in cases where changes in  
output capacity may influence operation.  
The output specifications change. Check that correct  
operation is possible in cases where changes in output  
specifications may influence operation. (Residual voltage  
increases from 0.8V to 1.5V, ON response time increases  
from 0.1ms to 0.5ms, OFF response time increases from  
0.3ms to 1ms.)  
The output specifications change. Check that correct  
operation is possible in cases where changes in output  
specifications may influence operation. (Residual voltage  
increases from 0.8V to 1.5V, ON response time increases  
from 0.1ms to 0.5ms, OFF response time increases from  
0.3ms to 1ms.)  
Notes  
Notes  
The internal 5-V current consumption increases (from  
180mA to 270mA). Check that the increased current is  
within the range of the power supply.  
The internal 5-V current consumption increases (from  
160mA to 170mA). The external 24-V power supply  
current also increases (from 35mA to 40mA). Check that  
the increased current is within the range of the power  
supply.  
64-point Sinking Transistor Output Units  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-OD219  
There are no alarm output contacts. Use the alarm bits in  
the Auxiliary Area.  
Model number  
CS1W-OD261  
64-point Transistor Output (sinking) Units with connectors.  
The connectors and the pin arrangement are the same.  
The output current capacity increases (from 100mA to  
0.3A per point, 1.6A per common, and 6.4A per Unit). The  
load voltage range changes from 4.5 to 26.4V to 10.2 to  
26.4V.  
32-point Sinking Transistor Output Units  
Description  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
C200H-OD218  
Model number  
CS1W-OD231  
There are 4 commons instead of 2. Connect where  
necessary.  
32-point Transistor Output (sinking) Units with connectors.  
The connectors and the pin arrangement are the same.  
The output current capacity increases (from 100mA to  
0.5A per point, 2.5A per common, and 5A per Unit). The  
load voltage range changes from 4.5 to 26.4V to 10.2 to  
26.4V.  
The output specifications change. Check that correct  
operation is possible in cases where changes in output  
specifications may influence operation. (Residual voltage  
increases from 0.8V to 1.5V, ON response time increases  
from 0.1ms to 0.5ms, OFF response time increases from  
0.4ms to 1ms.)  
Description  
Notes  
There are 2 commons instead of 1. Connect where  
necessary.  
Replacement is not possible for applications with an output  
load range of 4.5 to 10.2V.  
The output specifications change. Check that correct  
operation is possible in cases where changes in output  
specifications may influence operation. (Residual voltage  
increases from 0.8V to 1.5V, ON response time increases  
from 0.1ms to 0.5ms, OFF response time increases from  
0.4ms to 1ms.)  
The internal 5-V current consumption increases (from  
270mA to 390mA). Check that the increased current is  
within the range of the power supply.  
Notes  
Replacement is not possible for applications with an output  
load range of 4.5 to 10.2V.  
16-point 100-VAC Input Units  
The internal 5-V current consumption increases (from  
180mA to 270mA). Check that the increased current is  
within the range of the power supply.  
Corresponding  
CS1 I/O Unit  
Item  
C200H I/O Unit  
Model number  
Description  
C200H-IA122/122V  
CS1W-IA111  
16-point 100-VAC Input Units with terminal blocks.  
100-VDC input also possible.  
The terminal arrangement must be changed.  
The input specifications change. Check that correct  
operation is possible in cases where changes in input  
specifications may influence operation. (ON voltage  
increases from 60VAC min. to 65VAC min. and the input  
impedance (50Hz) increases from 9.7kΩ to 10kΩ.)  
Notes  
The internal 5-V current consumption increases (from  
10mA to 110mA). Check that the increased current is  
within the range of the power supply.  
Programmable Controllers SYSMAC CS1G/H  
55  
MEMO  
56  
Read and Understand this Catalog  
Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have  
any questions or comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year  
(or other period if specified) from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT,  
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER  
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET  
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR  
IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS  
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON  
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE  
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED,  
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE  
MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the  
product in the customer's application or use of the product.  
Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will  
be used.  
Know and observe all prohibitions of use applicable to this product.  
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT  
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON  
PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR  
SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with  
your OMRON representative at any time to confirm actual specifications of purchased product.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a  
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application  
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability.  
OMRON Corporation  
Tokyo, JAPAN  
Industrial Automation Company  
Authorized Distributor:  
Contact: www.ia.omron.com  
Regional Headquarters  
OMRON EUROPE B.V.  
Wegalaan 67-69-2132 JD Hoofddorp  
The Netherlands  
OMRON ELECTRONICS LLC  
One Commerce Drive Schaumburg,  
IL 60173-5302 U.S.A.  
Tel: (31)2356-81-300/Fax: (31)2356-81-388  
Tel: (1) 847-843-7900/Fax: (1) 847-843-7787  
© OMRON Corporation 2001-2010 All Rights Reserved.  
In the interest of product improvement,  
specifications are subject to change without notice.  
OMRON (CHINA) CO., LTD.  
Room 2211, Bank of China Tower,  
200 Yin Cheng Zhong Road,  
PuDong New Area, Shanghai, 200120, China  
Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200  
OMRON ASIA PACIFIC PTE. LTD.  
No. 438A Alexandra Road # 05-05/08 (Lobby 2),  
Alexandra Technopark,  
Singapore 119967  
Tel: (65) 6835-3011/Fax: (65) 6835-2711  
Printed in Japan  
CSM_1_1_0412  
Cat. No. P047-E1-11  
0910-1101  

相关型号:

SI9130DB

5- and 3.3-V Step-Down Synchronous Converters

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135LG-T1-E3

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9135_11

SMBus Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9136_11

Multi-Output Power-Supply Controller

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130CG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130LG-T1-E3

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9130_11

Pin-Programmable Dual Controller - Portable PCs

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137DB

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications

Warning: Undefined variable $rtag in /www/wwwroot/website_ic37/www.icpdf.com/pdf/pdf/index.php on line 217
-
VISHAY

SI9137LG

Multi-Output, Sequence Selectable Power-Supply Controller for Mobile Applications