A9TS11-0012 [OMRON]

Ultra subminiature Toggle Switch;
A9TS11-0012
型号: A9TS11-0012
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Ultra subminiature Toggle Switch

文件: 总4页 (文件大小:700K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Ultra subminiature Toggle Switch  
Ultra subminiature size.  
A9TS  
Gold-plated clip contact ensure high reliability.  
The sealed bottom prevents flux penetration.  
Washable, equivalent to IP64 (IEC-60529).  
A9TS is smaller than A9T.  
Height: A9T 17mm A9TS 11mm (35% smaller than A9T)  
RoHS Compliant  
Typical Applications  
Security Control Boards  
Electric Power Instrumentation  
Program Controllers  
List of Models  
Actuator Shape  
Standard  
Terminal Shape  
DIP Terminal  
Right Angle Terminal  
Vertical Mount Terminal  
Switching Functions  
SPDT  
DPDT  
SPDT  
DPDT  
SPDT  
DPDT  
ON  
ON  
OFF  
ON  
ON  
A9TS11-0011 A9TS21-0011 A9TS11-0012 A9TS21-0012 A9TS11-0013 A9TS21-0013  
A9TS12-0011 A9TS22-0011 A9TS12-0012 A9TS22-0012 A9TS12-0013 A9TS22-0013  
Quantity per tray  
100  
25  
50  
Note: 1. Lever do not stop at "-" position.  
2. Switching Functions show the view from the side of Type and Brand name marking.  
Ratings/Characteristics  
Rating (resistive load)  
14 mA at 28 VAC/DC, 0.1 μA (minimum current) at 20 mVAC/DC  
20 °C to +80 °C 60% RH max. (with no icing or condensation)  
45 to 85% RH (at +5 to +35 °C)  
500 MΩ min. (at 500 VDC with insulation tester)  
80 mΩ max.  
Ambient operating temperature  
Ambient operating humidity  
Insulation resistance  
Contact resistance (initial value)  
Dielectric strength  
500 VAC for 1min between terminals, between terminals and ground  
Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude  
500 m/s2 min.  
50,000 operations min.  
50,000 operations min.  
IEC IP64  
Shock resistance  
Durability  
Malfunction  
Mechanical  
Electrical  
Degree of protection  
Washing  
Possible  
Operating forcse  
Weight  
4.9 N max.  
0.3 g  
1
A9TS  
A9TS  
Dimensions (Unit: mm)  
DIP Terminal Models  
11  
3.8  
1.6  
2.5±  
0.3  
(5.6)  
1.7 dia.  
0.±5  
0.2  
(6)  
(±)  
(3)  
(2)  
(1)  
(6)  
(5)  
(±)  
(3)  
(2)  
(1)  
2.5±  
2.5±  
±±°  
28°  
7
Marking Side  
Double Pole Type  
Single Pole Type  
Note: NO.(4) and (6) terminals in the SPDT models are dummys to support the Switch case.  
Right Angle Terminal Models  
11  
3.8  
(5.6)  
1.6  
0.±5  
1.7 dia.  
0.2  
(3)  
(2)  
(1)  
(6)  
(5)  
(±)  
(3)  
(2)  
(1)  
2.5±  
2.5±  
±±°  
28°  
7
Double Pole Type  
Marking Side  
Single Pole Type  
0.3  
2.6  
3.1  
2.5±  
5.08  
Vertical Mount Terminal Models  
11  
3.8  
1.6  
2.5±  
0.3  
(5.6)  
1.7 dia.  
(3)  
(2)  
(1)  
(6)  
(5)  
(±)  
(3)  
(2)  
(1)  
±±°  
28°  
7
Marking Side  
0.±5  
2.5±  
5.08  
Double Pole Type  
Single Pole Type  
2.5±  
Note: Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.  
2
A9TS  
A9TS  
PCB Dimensions (Top View)  
DIP Terminal Models  
Right Angle Terminal Models  
2.54  
Five-0.6+0.1dia.  
2.54  
Six-0.6 +0.1dia.  
5.08  
2.54  
Five-0.6+0.1dia.  
5.08  
Eight-0.6+0.1dia.  
0
0
0
0
(4)  
(5)  
(6)  
(4)  
(6)  
(3)  
(1)  
(2)  
(1)  
(2)  
(3)  
(6)  
(5)  
5.08  
5.08  
5.08  
5.08  
(2)  
(2)  
(1)  
(3)  
(3)  
(1)  
(4)  
Single Pole Type  
Double Pole Type  
Single Pole Type  
Double Pole Type  
Vertical Mount Terminal Models  
2.54  
2.54  
5.08  
5.08  
(4)  
(1)  
(1)  
(2)  
(3)  
(5)  
(6)  
(2)  
5.08  
5.08  
(3)  
Eight-0.6+0.1dia.  
Five-0.6+0.1dia.  
0
0
Single Pole Type  
Double Pole Type  
Switching Function / Internal Connections  
Switching Functions  
ON  
ON  
ON  
ON  
3
3
1
2
SPDT Models  
DPDT Models  
2
3
1
1
OFF  
2
ON  
ON  
ON  
ON  
3
3
2
2
5
1
6
1
6
3
2
5
5
4
4
1
6
4
OFF  
Note: Lever do not stop at "" position.  
3
A9TS  
A9TS  
Safety Precautions  
Be sure to read the Safety precautions common to all PCB-mount Manual Switch for correct use.  
Cautions  
Using Flux  
Use the switch within the rated voltage and current ranges,  
otherwise the Switch may have a shortened life expectancy,  
radiate heat,or burn out. This particularly applies to the  
instantaneous voltages and currents when switching.  
Making mistakes in the type of flux or in the amount or method in  
which it is applied can cause flux to enter the interior of the  
Switch, with adverse effects on Switch performance. Assess the  
proper flux, conditions,and methods prior to using it.  
Hardling  
RoHS Compliant  
Do not apply excessive operating force to the Switch. Otherwise  
The "RoHS Compliant" designation indicates that the listed  
the Switch may be damaged or deformed, and the switch  
mechanism may malfunction as a result. Apply an operating force  
not exceeding 9.8N {1,000gf}. Apply the operating load from the  
top of the actuator. Do not apply a load from angle or from side  
the actuator. Doing so may deform the Switch contact.  
models do not contain the six hazardous substances covered by  
the RoHS Directive.  
Reference: The following standards are used to determine  
compliance for the six substances.  
• Lead:  
• Mercury:  
• Cadmium:  
1,000 ppm max.  
1,000 ppm max.  
100 ppm max.  
Soldering  
Observe the following conditions when soldering the Switch.  
Automatic Soldering Bath  
• Hexavalent chromium: 1,000 ppm max.  
• PBB:  
• PBDF:  
1,000 ppm max.  
1,000 ppm max.  
Soldering temperature: 260  
Soldering time: 5s max.  
Manual Soldering  
°C max. (Preheating: 100 °C 120s max.)  
Environment for Storage and Use  
To prevent discoloration of the terminals and other problems  
during storage, do not store the Switch in locations subject to the  
following conditions.  
1. High temperature or humidity  
2. Corrosive gases  
Soldering temperature: 350 °C at the tip of the soldering iron.  
Soldering time: 3s max.  
Washing  
Apply alcohol based solvents to clean.  
Do not clean the Switch immediately after soldering. Wait for at  
least five minutes after soldering before cleaning.  
Ultrasonic cleaning is not available dip into Switch washing  
agents for two minutes maximum.  
3. Direct sunlight  
Also, the Switch is not waterproof or splash-resistance.  
Do not use the Switch in locations that are subject to contact with  
water. Do not subject the Switch to freezing or condensation.  
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.  
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad  
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious  
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or  
equipment, and be sure to provide the system or equipment with double safety mechanisms.  
Note: Do not use this document to operate the Unit.  
OMRON Corporation  
Electronic and Mechanical Components Company  
Contact: www.omron.com/ecb  
Cat. No. A199-E1-04  
1014(0207)(O)  

相关型号:

A9TS11-0013

Ultra subminiature Toggle Switch
OMRON

A9TS12-0011

Ultra subminiature Toggle Switch
OMRON

A9TS12-0012

Ultra subminiature Toggle Switch
OMRON

A9TS12-0013

Ultra subminiature Toggle Switch
OMRON

A9TS21-0011

Ultra subminiature Toggle Switch
OMRON

A9TS21-0012

Ultra subminiature Toggle Switch
OMRON

A9TS21-0013

Ultra subminiature Toggle Switch
OMRON

A9TS22-0011

Ultra subminiature Toggle Switch
OMRON

A9TS22-0012

Ultra subminiature Toggle Switch
OMRON

A9TS22-0013

Ultra subminiature Toggle Switch
OMRON

A9V11363

Equipment Leakage Circuit Breaker,
SCHNEIDER

A9V51263

Equipment Leakage Circuit Breaker,
SCHNEIDER