A3CJ-90E1-24EW [OMRON]
Pushbutton Switch;型号: | A3CJ-90E1-24EW |
厂家: | OMRON ELECTRONICS LLC |
描述: | Pushbutton Switch |
文件: | 总14页 (文件大小:1884K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
A3C
Pushbutton Switch (Lighted/Non-Lighted) (Cylindrical 12-dia.)
CSM_A3C_DS_E_2_1
Pushbutton Switch Series with
Cylindrical 20-mm × 12-dia. Body
• High-intensity uniform surface lighting.
• Round body enables easy hole making.
• Miniature size with excellent feeling of operation.
RoHS Compliant
Refer to Safety Precautions for All Pushbutton Switches and
Safety Precautions on page 12.
List of Models
Appearance
Model
Rectangular
Models
A3CJ
Square
Models
A3CA
A3CT
Round
Models
■ Specifications: Refer to page 8. ■ Dimensions: Refer to page 10. ■ Accessories: Refer to page 7.
■ Precautions for correct use and safety precautions: Refer to page 12.
1
A3C
Model Number Legend.............................................When placing your order, specify the individual component part model numbers of
the Pushbutton, Lamp (lighted models only), and Switch, as listed in the ordering
tables below.
For information on combinations, refer to Ordering Information on page 3.
(1)
(2) (3) (4)
(5)
(6)
A 3 C J - 9 0 A 1 - 2 4 E R
(5) Lighting
Method
LED Lamp-lighted
Models
(3) Switch Specifications
Standard Load
(4) Lighted/Non-
lighted
(6) Color of
Pushbutton
For LED
(1) Shape of
Pushbutton
(2) Terminal Type
Sym-
Type
bol
Sym-
bol
Sym-
Type
bol
Sym-
Shape
bol
Operation
Lamp
0
Solder terminal
A
Momentary
Alternate
0
Non-lighted
Rectan-
gular
Sym- Operating
Sym-
Color
bol
J
1a1b
1a1b
bol
voltage
B
Illumination
only
1
A
T
Square
Round
05E
12E
24E
5 VDC
R
Y
Red
12 VDC
24 VDC
• Colored-illumina-
tion models are
also available.
Yellow
Green
White
Microload
G
W
Sym-
bol
Operation
Momentary
Alternate
Refer to page 4.
E
F
"Colored-illumi-
nation" models
operate in the
way shown be-
low:
For
Incandescent
Lamp
Incandescent
Lamp-lighted
Models
• Standard Load
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
• Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Sym-
Color
bol
Sym-
bol
Operating
voltage
Unlit
Lit
R
Y
Red
Yellow
Green
Blue
White
Color
06
14
28
5 VAC/VDC
12 VAC/VDC
24 VAC/VDC
The built-in LED
is colored.
G
A
Minimum applicable load
1 mA at 5 VDC
W
White
Momentary-action: Self-resetting
Alternate-action: Self-holding
For Non-
lighted
Models
Non-lighted
Models
No symbol
Sym-
bol
Color
R
Red
Yellow
Green
White
Blue
Y
G
W
A
B
Black
2
A3C
Ordering Information
Ordering as a Set ................................ The model numbers used to order sets of Units are given in the following tables. One set comprises
the Pushbutton, Lamp (lighted models only), and Switch.
Round
Models
Rectangular
Models
Square
Models
A3CT
A3CJ
A3CA
Lighted Pushbutton Switches (SPST-NO+SPST-NC Solder Terminals)
Standard load
Operation
Microload
Momentary operation (Self-resetting)
Set
Alternate operation (Self-holding)
Momentary operation (Self-resetting)
Pushbutton
color symbol
(Color)
Shape
Lighting
Set
Set
A3CJ-90A1-05E@
A3CJ-90A1-12E@
A3CJ-90A1-24E@
A3CJ-90A1-06@
A3CJ-90A1-14@
A3CJ-90A1-28@
A3CJ-90A0-@
A3CJ-90B1-05E@
A3CJ-90B1-12E@
A3CJ-90B1-24E@
A3CJ-90E1-05E@
A3CJ-90E1-12E@
A3CJ-90E1-24E@
R: red
Y: yellow
G: green
W: white
LED lamp
Rectangular
(A3CJ)
R: red
---
Y: yellow
G: green
W: white
A: blue
Incandescent
lamp
---
A3CJ-90B1-28@
A3CJ-90B0-@
Non-lighted
LED lamp
A3CJ-90E0-@
B: black *
A3CA-90A1-05E@
A3CA-90A1-12E@
A3CA-90A1-24E@
A3CA-90A1-06@
A3CA-90A1-14@
A3CA-90A1-28@
A3CA-90A0-@
A3CA-90B1-05E@
A3CA-90B1-12E@
A3CA-90B1-24E@
A3CA-90E1-05E@
A3CA-90E1-12E@
A3CA-90E1-24E@
R: red
Y: yellow
G: green
W: white
Square
(A3CA)
R: red
---
Y: yellow
G: green
W: white
A: blue
Incandescent
lamp
---
A3CA-90B1-28@
A3CA-90B0-@
Non-lighted
LED lamp
A3CA-90E0-@
B: black *
A3CT-90A1-05E@
A3CT-90A1-12E@
A3CT-90A1-24E@
A3CT-90A1-06@
A3CT-90A1-14@
A3CT-90A1-28@
A3CT-90A0-@
A3CT-90B1-05E@
A3CT-90B1-12E@
A3CT-90B1-24E@
A3CT-90E1-05E@
A3CT-90E1-12E@
A3CT-90E1-24E@
R: red
Y: yellow
G: green
W: white
Round
(A3CT)
R: red
---
Y: yellow
G: green
W: white
A: blue
Incandescent
lamp
---
A3CT-90B1-28@
A3CT-90B0-@
Non-lighted
A3CT-90E0-@
B: black *
Note: 1. Enter the desired color symbol for the Pushbutton in the @ at the end of the model number.
2. There are also alternate-operation models that can be used for microloads. Refer to the Switch table on page 6.
* Black ("B") Pushbuttons are only available for non-lighted models.
Individual models: Refer to pages 5 to 6.
■ Specifications: Refer to page 8. ■ Dimensions: Refer to page 10.
(The Pushbutton, Lamp, and Switch can be ordered separately.)
■ Accessories: Refer to page 7.
3
A3C
Ordering Information
Illumination-only and Colored-illumination LED Models
"Illumination only" describes LED models for which the screen color is the same whether the LED is lit or not.
Example: Red LED
Not lit
Cap (red)
Red
Pushbutton
Legend plate (milky white)
Reflective plunger
Lit
Red
LED lamp (red) - - - Lamp
"Colored illumination" describes LED models for which the screen color is white when the LED is not lit and changes to the color of the LED lamp
when the LED is lit.
Example: Red LED
Not lit
White cap (semi-transparent)
White
Pushbutton
Legend plate (milky white)
Reflective plunger
Lit
Red
LED lamp (red) - - - Lamp
Ordering: With colored-illumination models, order the Pushbutton, Lamp, and Switch as shown in the following table.
Illuminated color
Pushbutton
Lamp (LED)
Switch
Red
A16-@DR
A16-@DY
A16-@DG
IP40
A3C@-500W
Enter one of the
following symbols in @.
5: 5 VDC
Enter one of the following sym-
bols in @.
Refer to page 6. Make the se-
lection according to the
Yellow
Green
J: Rectangular
A: Square
T: Round
12: 12 VDC
shape of the Pushbutton.
24: 24 VDC
4
A3C
Ordering Information
Ordering Individually ............... Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Ordering: Specify a model number from the following page.
LED Lamp
Non-lighted Models
Operation Unit
Operation Unit
Lamps
LED Lamp
Incandescent Lamp
Switch
Switch
Ordering set combinations: Refer to page 3.
■ Specifications: Refer to page 8. ■ Dimensions: Refer to page 10.
■ Accessories: Refer to page 7.
5
A3C
Ordering Information
Ordering Individually................Pushbuttons, Lamps, and Switches can be ordered separately. Combinations that are not available as
sets can be created using individual Units. Also, store the parts as spares for maintenance and repairs.
Pushbuttons
LED Lamp
Non-lighted Models
Square
Round
Square
Round
Rectangular
Rectangular
Shape
Shape
Button color
Button color
Red
A3CJ-500R
A3CJ-500Y
A3CJ-500GY
A3CJ-500W
A3CA-500R
A3CA-500Y
A3CA-500GY
A3CA-500W
A3CT-500R
A3CT-500Y
A3CT-500GY
A3CT-500W
Red
Yellow
Green
White
Blue
A3CJ-500R
A3CJ-500Y
A3CJ-500G
A3CJ-500W
A3CJ-500A
A3CJ-501B
A3CA-500R
A3CA-500Y
A3CA-500G
A3CA-500W
A3CA-500A
A3CA-501B
A3CT-500R
A3CT-500Y
A3CT-500G
A3CT-500W
A3CT-500A
A3CT-501B
Yellow
Green
White
Note: The red, yellow, and white Pushbuttons listed above can be used with
either LED lamp-lighted models or incandescent lamp-lighted models.
Black
Note: Models other than black can also be used with incandescent lamps.
Incandescent Lamp
Square
Round
Rectangular
Shape
Button color
Red
Yellow
Green
White
Blue
A3CJ-500R
A3CJ-500Y
A3CJ-500G
A3CJ-500W
A3CJ-500A
A3CA-500R
A3CA-500Y
A3CA-500G
A3CA-500W
A3CA-500A
A3CT-500R
A3CT-500Y
A3CT-500G
A3CT-500W
A3CT-500A
Lamps
LED Lamp
Incandescent Lamp
Rated voltage
6 VAC/DC
Model
A16-5
Color
Rated voltage
Red
Yellow
Green
White
5 VDC
A16-5DR
A16-12DR
A16-24DR
A16-5DY
A16-12DY
A16-24DY
A16-5DG
A16-12DG
A16-24DG
A16-5DW
A16-12DW
A16-24DW
14 VAC/DC
28 VAC/DC
A16-12
A16-24
12 VDC
24 VDC
Switches
Sealing
Degree of protection: IP40
Square
Rectangular
Round
Shape
Contact type
Switch action
Terminal
Momentary
Alternate
A3CJ-7011
A3CJ-7021
A3CJ-7111
A3CJ-7121
A3CA-7011
A3CA-7021
A3CA-7111
A3CA-7121
A3CT-7011
A3CT-7021
A3CT-7111
A3CT-7121
Standard load
Solder
Solder
SPST-NO+
SPST NC
Momentary
Alternate
Microload
Ordering set combinations: Refer to page 3.
■
Specifications: Refer to page 8. ■ Dimensions: Refer to page 10.
■ Accessories: Refer to page 7.
6
A3C
Ordering Information
Accessories, Replacements, and Tools
Accessories
Name
Appearance
Classification
Model
Remarks
Wire-wrap terminal
A3C-4101
PCB terminal
A3C-4102
A3C-4103
Socket
Cannot be used with Insulation Cover.
Solder terminal
Insulation Cover
Switch Guard
Dust Cover
---
A3C-3002
Cannot be used with Socket.
For rectangular models
For square, round models
A3CJ-5050
A3CA-5050
Cannot be used with Dust Cover.
Cannot be used with Switch Guard.
Can be used with Dust Cover attached.
For rectangular models
A3CJ-5060
Tools
Name
Appearance
Classification
Model
Remarks
Tightening Tool
Extractor
---
A3C-3004
The tightening torque is 0.20 to 0.39 N·m.
---
A3PJ-5080
---
Replacements
Name
Appearance
Classification
Model
Remarks
For rectangular models
A3CJ-5201
One Legend Plate (milk-white) is supplied per
standard Switch.
For square models
For round models
A3CA-5201
A3CT-5201
Legend Plate
■ Specifications: Refer to page 8. ■ Dimensions: Refer to page 10.
7
A3C
Approved Standard Ratings
Characteristics
UL (File No. E41515), CSA (File No. LR45258)
Momentary-action models: 120 operations/minute max.
Alternate-action models: 60 operations/minute max. *1
Operat-
ing fre-
quency
Mechanical
Standard Load:
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Electrical
20 operations/minute max.
Standard load
50mΩ max.
Contact
Resis-
tance
Microload:
0.1 A at 125 VAC
0.1 A at 30 VDC
Microload
100mΩ max.
Note: Certification has been obtained for the Switch Unit.
For detailed information on individual products that have received
certification, consult your supplier.
Insulation resistance
100 MΩ min. (at 500 VDC)
Between terminals
1,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
2,000 VAC, 50/60 Hz for 1 min
1,000 VAC, 50/60 Hz for 1 min *2
of same polarity
CCC (GB14048.5)
Standard Load:
Microload:
Between terminals
of different polarity
0.5 A at 250 VAC
0.1 A at 250 VAC
Dielectric
strength
Between each
terminal and ground
Ratings
Between lamp
terminals
Model
Item
AC resistive load
DC resistive load
1 A at 30 VDC
0.5 A at 250 VAC
1 A at 125 VAC
Vibration
resis-
tance
Standard load
Microload *
Malfunction
10 to 55 Hz, 1.5-mm double amplitude *3
0.1 A at 125 VAC
0.1 A at 30 VDC
Shock
resis-
tance
Destruction
Malfunction
500 m/s2
Note: The above ratings are for testing under the following conditions:
1) Load: Resistive load
2) Mounting conditions: No vibrations or shock
3) Temperature: 20°C ± 2°C
4) Operation frequency: 20 operations/minute
* The minimum permissible load is 1 mA, 5 VDC.
150 m/s2 *3
Momentary-operation models: 1,000,000 operations min.
Alternate-operation models: 100,000 operations min. *1
Mechanical
Electrical
Durability
100,000 operations min.
LED Lamp
Approx. 5 g <The weight indicated here applies
to the lighted models (SPST-NO+SPST-NC).>
Weight
Operating
voltage
Internal limiting
resistance
Rated voltage
Rated current
Ambient operating temperature
−10°C to +55°C (with no icing or condensation)
5 VDC
12 VDC
24 VDC
30 mA
15 mA
10 mA
5 VDC ± ±5%
12 VDC ± ±5%
24 VDC ± ±5%
33 Ω
270 Ω
1,600 Ω
Ambient operating humidity 35% to 85%RH
Ambient storage temperature
Degree of protection
−25°C to +65°C (with no icing or condensation)
IP40
Electric shock protection class
Class II
Incandescent Lamp
PTI (proof tracking index) 175
Rated voltage
6 VAC/DC
Rated current
Operating voltage
5 VAC/DC
Pollution degree
3 (IEC60947-5-1)
60 mA
40 mA
24 mA
14 VAC/DC
28 VAC/DC
12 VAC/DC
*1. With alternate-operation models, one operation cycle consists of set and
reset operations.
*2. The figure given above for the dielectric strength between lamp terminals is
for when there is no LED lamp or incandescent lamp mounted.
*3. No malfunction for more than 1s.
24 VAC/DC
Operating Characteristics
Operating force
Releasing force
Total travel
OF max.
RF min.
TT
2.45 N {250 gf}
0.29 N {30 gf}
Approx. 3.5 mm
0.5 mm
Lock travel alternate LTA min. *
Pretravel PT max.
2.5 mm
* Alternate operation models only.
Contact Form
Contact name
Contact form
NO
NC
NO
NC
SPDT
8
A3C
Nomenclature
Model Structure
Display Unit Structure
Color cap
(1) Shape of Pushbutton
(2) Color of Pushbutton
Legend Plate
Pushbutton
Lamp
Reflective
plunger
(3) Type of Lamp
(4) Switch Specifications
Switch
Note: The A3CJ model is shown here as a representative example.
Type
Shape of Pushbutton
Rectangular Square
(A3CJ) (A3CA)
Specifications
Round
(A3CT)
(1)
(2)
------
LED lamp-lighted Models:
Red, Yellow, Green, White
Incandescent lamp-lighted Models:
Red, Yellow, Green, White, Blue
Non-lighted Models:
------
Red, Yellow, Green, White, Blue, Black
LED Lamp
(3)
(4)
Incandescent Lamp
0.5 A at 250 VAC
1 A at 125 VAC
1 A at 30 VDC
Standard load
Microload
0.1 A at 125 VAC
0.1 A at 30 VDC
Minimum applicable load: 1 mA at 5 VDC
9
A3C
Dimensions
(Unit: mm)
Rectangular Models/A3CJ
Square Models/A3CA
Round Models/A3CT
9.5
6
20
20
9.5
20
9.5
9.5
1
6
9.5
6
9.5
0.6
0.6
0.6
M12 × 1
M12 × 1
M12 × 1
14 11.8
14 dia.11.8 dia.
14 11.8
11.8
14
26.5
26.5
15.7
18
26.5
Terminal Connections
Terminal
SPST-NO + SPST-NC Lighted and non-lighted models
Terminal Arrangement
(BOTTOM VIEW)
0.6
6.5
t0.4
1.6
Lamp terminal
t0.3
NC
NC
NO
NO
L+
L-
Solder terminal
Terminal hole
2
0.8
0.8
Panel Cutout (Top View)
Accessories used
Rectangular/A3CJ
Square/A3CA, Round/A3CT
7.5 0.1
+0.2
12 dia.
19 min.
2 dia. (Lock hole)
5.5 0.1
0
15 min.
12 dia.+0.2
0
Switch only
15 min.
Note: Recommended panel thickness: 1.0 to 3.2 mm.
Note: Recommended panel thickness: 1.0 to 3.2 mm.
7.5 0.1
+0.2
+0.2
12 dia.
0
12 dia.
22.5 min.
2 dia.
0
19 min.
5.5 0.1
With Switch Guard
19 min.
19 min.
7.5 0.1
+0.2
0
2 dia.
12 dia.
23.5 min.
5.5 0.1
With Dust Cover
----------
19.5 min.
• If the panel is to be finished (e.g., coated), make sure that the panel meets the specified dimensions after the coating.
10
A3C
Dimensions
(Unit: mm)
Accessory Mounting Dimensions
Dimensions with Socket Mounted (The diagrams below show the external dimensions for rectangular models as representative models.)
Wire-wrap Terminal/A3C-4101
PCB Terminal/A3C-4102
Solder Terminal/A3C-4103
1
33.6
33.6
15.8
3.5
33.6
5
16.7
16.7
16.7
1
0.6 1.6
3.2
1.6
3.55
13.9 dia.
13.9 dia.
13.9 dia.
3.55
3.2
0.3
1
0.3
4.7
7
3.55
7
PCB Cutout
(BOTTOM VIEW)
Terminal Hole Dimensions
9.7 0.1
Six, 0.8 dia.
2
0.5
5.1 0.1 7.4 0.1
0.8
Switch Guard
Rectangular
A3CJ-5050
Square/Round
A3CA-5050
24.5
18
13.5
24.5
18
1
13.5
Holder (black)
Guard (transparent)
Holder (black)
Guard (transparent)
9
9
18
18
21.5
Torsion spring
18
Torsion spring
Dust Cover
A3CJ-5060
Legend Plate
Insulation Cover
A3C-3002
Rectangular Square
Round
24.5
18
13.8
0.8
33.6
18
9.6
10.1
10.1
13.9 dia.
10.1
14
10.1 dia.
Note: 1. The thickness is 0.8 mm.
2. Since the Legend Plate is made of
Cover A (black)
Cover B (transparent)
polycarbonate, use alcohol-based paints
such as melanin, phthalic acid, or acrylic
paint when marking the legend.
18.5
1
22.5
11
A3C
Safety Precautions
Refer to Safety Precautions for All Pushbutton Switches.
CAUTION
Do not apply a voltage higher than the maximum
rated operating voltage between the lamp terminals,
as there is a risk that the incandescent lamp or LED
lamp will be damaged, and the Pushbutton will be
ejected.
Using Microloads
• Using a standard load switch for opening and closing a microload
circuit may cause wear on the contacts. Use the switch within the
operating range. (Refer to the diagram below.) Even when using
microload models within the operating range shown below, if inrush
current occurs when the contact is opened or closed, it may cause
the contact surface to become rough, and so decrease life
expectancy. Therefore, insert a contact protection circuit where
necessary. The minimum applicable load is the N-level reference
value. This value indicates the malfunction reference level for the
reliability level of 60% (λ 60) (conforming to JIS C5003). The
equation, λ 60 = 0.5 x 10−6/times indicates that the estimated
malfunction rate is less than 1/2,000,000 with a reliability level of
60%.
When replacing the incandescent lamp, first turn OFF
the power supply, and then wait 10 minutes before
performing replacement, as the lamp is still hot
immediately after the power is turned OFF, so there
is a risk of burns.
Precautions for Correct Use
Mounting
• To prevent electric shock or a fire, always make sure that the power
is turned OFF before mounting, removing, or wiring the Switch, or
performing maintenance.
100mA
0.15mA
26mA
30
24
•
Do not tighten the mounting ring excessively using pliers or a similar
tool. Excessive tightening may damage the mounting ring.
Standard
load area
Microload
area
(Tightening torque: 0.20 to 0.39 N·m {20 gf to 40 gf})
Wiring
• When wiring, use wires of a size appropriate for the applied voltage
and carry current. Perform soldering correctly under the conditions
given below. Using the Switch with the wires soldered incorrectly
may cause the terminals to become abnormally hot and cause a
fire.
1. Soldering iron tip temperature: 350°C max. within 3 seconds.
2. Dip soldering: At 350°C within 3 seconds.
12
Invalid
area
5
0
100mA 150mA
1mA
1
0.1
10
100
1,000
Current (mA)
Wait for one minute after soldering before exerting any external
force on the solder.
LED
• Use a non-corrosive rosin liquid for the flux.
• Perform wiring so that the wire sheaths do not come into contact
with the Switch. If this is unavoidable, use wires that can withstand
temperatures of 100°C min.
• After wiring to the Switch has been completed, ensure an
appropriate insulation distance.
• Resistance to limit the LED current is provided internally and so an
external resistance is not required.
Rated voltage
5 VDC
Internal limiting resistance
33 Ω
270 Ω
1,600 Ω
12 VDC
Operating Environment
24 VDC
• Do not use in locations that are subject to dust, oil, or metal filings
as these may penetrate the interior of the Switch and cause
malfunction.
12
A3C
Application
Mounting and Replacing the Pushbutton
(1) Mounting Direction for the Pushbutton/Display and Lamp
Lighted Pushbutton Switch
• Insert the Lamp (incandescent lamp or LED lamp) into the
Pushbutton so that the lamp guide fits into the wider gap between
the projections on the Pushbutton.
Panel Mounting
• Insert the Switch from the front of the panel. Mount the mounting
nut from the terminal end of the Switch and tighten it.
• There are projections on the terminal end of the Switch which may,
depending on the orientation, block the nut. In this case, turn the nut
until it is possible to mount it. Tighten the nut to a torque between
0.20 and 0.39 N·m.
• If soldering is used, mount the mounting nut first. Lead wires and
mounds of solder may make it impossible to mount the nut after
soldering.
Projections
LED/lamp guide
LED/lamp guide
Mounting nut
Panel
Indicator
• With Indicators, the Lamp is inserted facing the opposite direction
(i.e., at 180°) to that for Lighted Pushbutton Switches.
LED/lamp guide
Socket Mounting
• After securing the Switch to the panel using the mounting nut, insert
the Socket into the Switch.
Groove of the Display
• Align the positioning holes of the Socket with the projections of the
Switch before inserting the Socket.
Projection of the LED/lamp
Note: Push the projections on the Lamp into the grooves on the Pushbutton/
Panel
Display.
The Lamp for Lighted Pushbutton Switches moves, but the Lamp for
Indicators is fixed.
Projection
of the Switch
(2) Mounting Direction for the Pushbutton/Display and Switch
• Insert the Pushbutton/Display into the Switch so that the lamp guide
is aligned with the non-projecting part of the Switch.
• Apply a pressure between 9.8 and 24.5 N.
Positioning
hole of the Socket
Projection
of the Switch
Mounting the Insulation Cover
• After securing the Switch to the panel using the mounting nut, pass
the lead wires through the holes in the Insulation Cover and then
perform wiring. Hold the Insulation Cover so that the cylindrical hole
is facing the Switch, and insert the lead wires from the end with the
barriers.
Note: 1. The mounting direction for Indicators is 180° to that for Lighted
Pushbutton Switches. Be sure to insert the Legend Plate and other
parts with the correct orientation.
2. If the terminals of the Lamp become bent, it may be impossible to fit
them into the lamp terminal holes. Ensure that the terminals are
straight when they are inserted.
• After wiring is completed, mount the Insulation Cover by pushing it
into the Switch.
3. Take particular care about the mounting direction with the round
models (A3CT).
Insulation Cover attached to Switch
Switch terminal
(3) Removing the Pushbutton/Display
Hold the recessed portions on the cap of the Pushbutton and pull.
Recess
Note: Do not use tools such as pliers to remove the Pushbutton as this may
damage the cap.
13
A3C
Mounting the Dust Cover
1. The Dust Cover separates into 2 parts: the cap and the mounting
frame.
2. Insert the Switch into the mounting frame. (Align the lock
projection with the recess on the mounting frame.)
3. Insert the Switch in the state described in step 2 into the panel.
(Align the lock protrusion on the mounting frame with the hole in
the panel.)
4. Mount the mounting nut from the back of the panel and tighten it.
5. Insert the cap into the mounting frame. Ensure that the entire
perimeter of the cap is properly inserted into the mounting frame
by pressing down on the cap from different directions.
Mounting nut
Cap (transparent)
Mounting frame
Panel
Switch
Lock protrusions
Mounting the Switch Guard
1. Insert the Switch into the Switch Guard.
2. Insert the Switch into the panel in the state described in step 1.
3. Mount the mounting nut from the back of the panel and tighten it.
Mounting nut
Panel
Holder (black)
Guard (transparent)
•±Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. A030-E1-05
0812(0207)(O)
14
相关型号:
A3CT-90A0-B
Pushbutton Switch, SPDT, Momentary, 1A, 30VDC, Solder Terminal, Panel Mount-threaded
OMRON
A3CT-90A1-05EG
Pushbutton Switch, SPDT, Momentary, 1A, 30VDC, Solder Terminal, Panel Mount-threaded
OMRON
A3CT-90A1-05ER
Pushbutton Switch, SPDT, Momentary, 1A, 30VDC, Solder Terminal, Panel Mount-threaded,
OMRON
©2020 ICPDF网 联系我们和版权申明