1VAP2-6 [OMRON]

Snap Acting/Limit Switch;
1VAP2-6
型号: 1VAP2-6
厂家: OMRON ELECTRONICS LLC    OMRON ELECTRONICS LLC
描述:

Snap Acting/Limit Switch

开关
文件: 总4页 (文件大小:451K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Door Switches  
1ZAP2/1VAP2  
CSM_1ZAP2_1VAP2_DS_E_3_1  
Door Switches with Built-in Basic  
Switches for Long Life  
• Installation in electrical facilities, equipment doors, and other  
openings helps ensure safety by reliably preventing accidents.  
• A Basic Switch if built in to provide a large switching capacity  
and long service life.  
Be sure to read Safety Precautions on page 3 and  
Safety Precautions for All Basic Switches.  
Ordering Information  
Specifications  
Operation  
Item  
Model  
1ZAP2  
Z-15GL42-B  
1VAP2-@  
Built-in Switch  
Model  
Push  
operation  
Pull  
Built-in Switch  
V-15-1B6/V-15-3B6  
operation  
15 A, 125 VAC  
(resistive load)  
15 A, 250 V  
15 A, 125 VAC  
(resistive load)  
15 A, 250 V  
Z-15GL42-B  
V-15-1B6  
1ZAP2  
Rating  
1VAP2-1  
1VAP2-2  
1VAP2-6  
(resistive load)  
(resistive load)  
Self-reset  
Hold  
Ambient operating  
temperature  
25 to 80°C (with no icing or condensation)  
V-15-3B6  
Ambient operating  
humidity  
35% to 85%RH  
Contact Form  
Mechanical 100,000 operations min. 100,000 operations min.  
Electrical 100,000 operations min. 25,000 operations min.  
Durability  
Model  
1ZAP2  
Name  
Contact form  
Degree of protection IP00  
Electric shock  
protection class  
NC  
Class II  
Double-throw  
(SPDT)  
1VAP2-1  
1VAP2-2  
COM  
COM  
NO  
PTI  
175  
(proof tracking index)  
Single-throw  
(SPST-NO)  
Pollution degree  
3 (IEC 947-5-1)  
1VAP2-6  
NO  
Note: 1. The 1VAP2-6 is also available with SPDT contacts. The model number  
is 1VAP2-6 (V-15-1B6).  
2. The built-in switch cannot be replaced.  
1
1ZAP2/1VAP2  
Dimensions  
(Unit: mm)  
1ZAP2  
Operating  
Characteristics  
Model  
1ZAP2  
5
6.4 dia. max.  
21.6 N  
4.7 mm  
3.2 mm  
Operating force OF max.  
Pretravel  
PT max.  
OT min.  
Overtravel  
#832UNC, Depth: 10  
(unified screw thread)  
Free position  
FP max.  
11.1 mm  
78.6  
6.4  
6.35 dia.  
5.5 0.4  
11.1  
34.9  
7.1  
11.1 0.13  
FP  
Four, M4 × 0.7  
7.9  
1
25.4  
0.13  
10.7 0.4  
19.5  
16.7  
0.4  
57.2  
Three, M4x5.5 binding machine screws  
Internal toothed washer  
Separator  
Z-15GL42-B  
1VAP2-1  
46.9 0.3  
31 0.2  
1VAP2-1  
FP  
4.6  
4.9  
4.8 dia.  
6.7 0.3  
17.6 N  
4.4 mm  
2 mm  
OF max.  
PT max.  
OT min.  
20.6 0.15  
0.3  
6.4  
7.4 dia. max.  
6.35 dia.  
10.3 0.3  
33 0.4  
FP max.  
9.5 mm  
5.5 0.2  
(39.8)  
12.7 0.2  
Two, M3.5  
6.8  
Two, M3.5 holes  
40.6  
Separator  
V-15-1B6 Basic Switch  
13.2  
Three, #4-40 UNC  
round machine screws  
1VAP2-2  
46.9 0.3  
31 0.2  
1VAP2-2  
4.9  
OF max.  
PT max.  
OT min.  
17.6 N  
4.4 mm  
2 mm  
4.1  
Three, M3 holes  
12.7  
FP  
4.8 dia.  
7.4 dia. max.  
6.35 dia.  
FP max.  
9.5 mm  
8.7 0.3  
46  
38.1 0.2  
19.1 0.2  
Separator  
Two, M3  
40.6  
6.4  
12.7  
7.9  
V-15-1B6 Basic Switch  
Three, #4-40 UNC  
round machine screws  
1VAP2-6  
Mounting hole  
FP  
1VAP2-6  
8
66 58 45  
8
Cover (steel)  
14.7 N  
6 mm  
3 mm  
OF max.  
PT max.  
OT min.  
12 dia.  
2
15  
FP max.  
21 mm  
6.35 dia.  
P = 1 criss-cross  
knurling  
11  
Stainless steel operation rod  
Two, 9-dia. lead wire  
pullout holes  
4.2 0.2  
1.2  
1
12  
37  
75.4  
V-15-3B6  
Basic Switch  
5
15.2  
10  
20  
Note: 1. The standard 1VAP2-6 has SPST-NO contacts.  
2. The 1VAP2-6 is also available with SPDT contacts. If SPDT contacts are required, order using the following model number. (The built-in switch is the V-15-1B6.)  
1VAP2-6 (V-15-1B6)  
2
1ZAP2/1VAP2  
Safety Precautions  
Refer to Safety Precautions for All Basic Switches.  
Precautions for Correct Use  
Mounting Holes  
Mounting  
direction  
1ZAP2  
1VAP2-1  
1VAP2-2  
1VAP2-6  
Four, M4 or 4.5 0.3dia. holes  
0
Two, 3.5+0.3dia. holes  
0
Two, 4+0.3dia. holes  
Two, 4.5+0.3dia. holes  
0
0
Front mounting  
58 0.3  
38.1 0.3  
25.4 0.3  
20.6 0.3  
37 0.3  
10 dia. min.  
10 dia. min.  
10 dia. min.  
0.3  
8.7  
10.3 0.3  
12.7 0.3  
11.1 0.3  
11.1 0.3  
Side mounting  
(Side mounting is not possible)  
38.1 0.3  
19.1 0.3  
Two, 4.5+0.3dia. holes  
Two, 4+0.3dia. holes  
0
0
Two, 3.5+0.3dia. holes  
0
Wiring  
Tighten the terminal screws to the torque given in the following table.  
1ZAP2  
1VAP2  
0.78 to 1.78 N·m  
0.19 to 0.29 N·m  
Operating Environment  
The Switch does not have a water-resistant structure. Take  
measures to protect the Switch if it is to be used in locations subject  
to splashing or spraying water or other liquids.  
Do not use the Switch where it is continuously subjected to vibration  
or shock. Doing so will result in contact failure, malfunction, or a  
decrease in service life caused by abrasive powder that is  
generated from the internal parts. Subjecting the Switch to  
excessive vibration or shock may cause the contacts to  
malfunction, stick, or become damaged. Make sure to install the  
Switch in locations free of vibration or shock or in a direction where  
resonance will not occur.  
Do not use the Switch in locations subject to corrosive gas, such as  
sulfuric gas (H2S or SO2), ammonium gas (NH3), nitric gas (HNO3),  
or chlorine gas (Cl2), or high temperature and humidity.  
Doing so will result in damage due to contact failure or corrosion.  
If the Switch is used in locations with silicone gas, arc energy may  
cause silicon dioxide (SiO2) to build up on the contacts and contact  
failure may result. If there is silicone oil, silicone sealant, or wire  
covered with silicone close to the Switch, attach a contact  
protective circuit to suppress the arcing of the Switch or eliminate  
the source of silicone gas.  
Use the switch within the specified range for operating temperature  
and humidity. Using the Switch in high temperatures will cause the  
operating characteristics to deviate. Rapid changes in temperature  
will also cause the operating characteristics to deviate. It is  
recommended to install the Switch as far as possible from heat  
sources so that the temperature of the Switch is not affected.  
3
Read and Understand This Catalog  
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or  
comments.  
Warranty and Limitations of Liability  
WARRANTY  
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)  
from date of sale by OMRON.  
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR  
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS  
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER  
WARRANTIES, EXPRESS OR IMPLIED.  
LIMITATIONS OF LIABILITY  
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS  
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT  
LIABILITY.  
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.  
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS  
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT  
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.  
Application Considerations  
SUITABILITY FOR USE  
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's  
application or use of the products.  
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the  
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,  
machine, system, or other application or use.  
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible  
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  
·
·
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.  
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,  
safety equipment, and installations subject to separate industry or government regulations.  
·
Systems, machines, and equipment that could present a risk to life or property.  
Please know and observe all prohibitions of use applicable to the products.  
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE  
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND  
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.  
PROGRAMMABLE PRODUCTS  
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.  
Disclaimers  
CHANGE IN SPECIFICATIONS  
Product specifications and accessories may be changed at any time based on improvements and other reasons.  
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.  
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or  
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual  
specifications of purchased products.  
DIMENSIONS AND WEIGHTS  
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.  
PERFORMANCE DATA  
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the  
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON  
Warranty and Limitations of Liability.  
ERRORS AND OMISSIONS  
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,  
typographical, or proofreading errors, or omissions.  
2009.5  
In the interest of product improvement, specifications are subject to change without notice.  
OMRON Corporation  
Industrial Automation Company  
http://www.ia.omron.com/  
(c)Copyright OMRON Corporation 2009 All Right Reserved.  

相关型号:

1VB

General Purpose RFI Power Line Filters General Purpose for High Impedance Loads at Low Cost
ETC

1VB1

General Purpose RFI Filters for High Impedance Loads at Low Current
TE

1VB3

General Purpose RFI Filters for High Impedance Loads at Low Current
TE

1VDK1

Enhanced Performance K Series RFI Power Line Filters
TE

1VDK1_11

Enhanced Differential Mode Performance K Series RFI Line Filters
TE

1VDK3

Enhanced Differential Mode Performance K Series RFI Line Filters
TE

1VK1

General Purpose RFI Power Line Filters-Ideal for High Impedance Load
TE

1VK1_11

General Purpose RFI Power Line Filters – Ideal for High Impedance Load
TE

1VK3

General Purpose RFI Power Line Filters-Ideal for High Impedance Load
TE

1VKE62(C)A

Transient Voltage Suppressors
FAIRCHILD

1VKE62A

Transient Voltage Suppressors
FAIRCHILD

1VKE62CA

Transient Voltage Suppressors
FAIRCHILD