P89C51RD2HBA [NXP]

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM; 80C51的8位闪存微控制器系列16KB / 32KB / 64KB ISP / IAP闪存与512B / 512B / 1KB RAM
P89C51RD2HBA
型号: P89C51RD2HBA
厂家: NXP    NXP
描述:

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM
80C51的8位闪存微控制器系列16KB / 32KB / 64KB ISP / IAP闪存与512B / 512B / 1KB RAM

闪存 微控制器
文件: 总52页 (文件大小:292K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
INTEGRATED CIRCUITS  
89C51RB2/89C51RC2/89C51RD2  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
Preliminary specification  
IC28 Data Handbook  
1999 Sep 23  
Philips  
Semiconductors  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
DESCRIPTION  
FEATURES  
The 89C51RB2/RC2/RD2 device contains a non-volatile  
16kB/32kB/64kB Flash program memory that is both parallel  
programmable and serial In-System and In-Application  
Programmable. In-System Programming (ISP) allows the user to  
download new code while the microcontroller sits in the application.  
In-Application Programming (IAP) means that the microcontroller  
fetches new program code and reprograms itself while in the  
system. This allows for remote programming over a modem link.  
A default serial loader (boot loader) program in ROM allows serial  
In-System programming of the Flash memory via the UART without  
the need for a loader in the Flash code. For In-Application  
Programming, the user program erases and reprograms the Flash  
memory by use of standard routines contained in ROM.  
80C51 Central Processing Unit  
On-chip Flash Program Memory with In-System Programming  
(ISP) and In-Application Programming (IAP) capability  
Boot ROM contains low level Flash programming routines for  
downloading via the UART  
Can be programmed by the end-user application (IAP)  
6 clocks per machine cycle operation (standard)  
12 clocks per machine cycle operation (optional)  
Speed up to 20 MHz with 6 clock cycles per machine cycle  
(40 MHz equivalent performance); up to 33 MHz with 12 clocks  
per machine cycle  
This device executes one machine cycle in 6 clock cycles, hence  
providing twice the speed of a conventional 80C51. An OTP  
configuration bit lets the user select conventional 12 clock timing  
if desired.  
Fully static operation  
RAM expandable externally to 64 kB  
4 level priority interrupt  
8 interrupt sources  
This device is a Single-Chip 8-Bit Microcontroller manufactured in  
advanced CMOS process and is a derivative of the 80C51  
microcontroller family. The instruction set is 100% compatible with  
the 80C51 instruction set.  
Four 8-bit I/O ports  
The device also has four 8-bit I/O ports, three 16-bit timer/event  
counters, a multi-source, four-priority-level, nested interrupt structure,  
an enhanced UART and on-chip oscillator and timing circuits.  
Full-duplex enhanced UART  
Framing error detection  
Automatic address recognition  
The added features of the P89C51RB2/RC2/RD2 makes it a  
powerful microcontroller for applications that require pulse width  
modulation, high-speed I/O and up/down counting capabilities such  
as motor control.  
Power control modes  
Clock can be stopped and resumed  
Idle mode  
Power down mode  
Programmable clock out  
Second DPTR register  
Asynchronous port reset  
Low EMI (inhibit ALE)  
Programmable Counter Array (PCA)  
PWM  
Capture/compare  
2
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
ORDERING INFORMATION  
PHILIPS  
(EXCEPT NORTH  
AMERICA)  
PART ORDER  
NUMBER  
PART MARKING  
PHILIPS  
NORTH  
AMERICA  
PART ORDER  
NUMBER  
MEMORY  
FREQUENCY (MHz)  
TEMPERATURE  
RANGE (°C)  
AND PACKAGE  
VOLTAGE  
RANGE  
DWG #  
FLASH RAM  
6 CLOCK  
MODE  
12 CLOCK  
MODE  
1
2
P89C51RB2HBP  
P89C51RB2HFP  
P89C51RB2HBA  
P89C51RB2HFA  
P89C51RB2HBB  
P89C51RB2HFB  
P89C51RC2HBP  
P89C51RC2HFP  
P89C51RC2HBA  
P89C51RC2HFA  
P89C51RC2HBB  
P89C51RC2HFB  
P89C51RD2HBP  
P89C51RD2HFP  
P89C51RD2HBA  
P89C51RD2HFA  
P89C51RD2HBB  
P89C51RD2HFB  
P89C51RB2BP  
P89C51RB2FP  
P89C51RB2BA  
P89C51RB2FA  
P89C51RB2BB  
P89C51RB2FB  
P89C51RC2BP  
P89C51RC2FP  
P89C51RC2BA  
P89C51RC2FA  
P89C51RC2BB  
P89C51RC2FB  
P89C51RD2BP  
P89C51RD2FP  
P89C51RD2BA  
P89C51RD2FA  
P89C51RD2BB  
P89C51RD2FB  
16 kB 512 B  
16 kB 512 B  
16 kB 512 B  
0 to +70, PDIP  
–40 to +85, PDIP  
0 to +70, PLCC  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT129-1  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT187-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
4.5–5.5 V 0 to 20 MHz 0 to 33 MHz SOT307-2  
3
4
16 kB 512 B –40 to +85, PLCC  
16 kB 512 B 0 to +70, PQFP  
16 kB 512 B –40 to +85, PQFP  
5
6
7
32 kB 512 B  
32 kB 512 B  
32 kB 512 B  
0 to +70, PDIP  
–40 to +85, PDIP  
0 to +70, PLCC  
8
9
10  
11  
12  
13  
14  
15  
16  
17  
32 kB 512 B –40 to +85, PLCC  
32 kB 512 B 0 to +70, PQFP  
32 kB 512 B –40 to +85, PQFP  
64 kB  
64 kB  
64 kB  
64 kB  
64 kB  
64 kB  
1 kB  
1 kB  
1 kB  
1 kB  
1 kB  
1 kB  
0 to +70, PDIP  
–40 to +85, PDIP  
0 to +70, PLCC  
–40 to +85, PLCC  
0 to +70, PQFP  
–40 to +85, PQFP  
18  
3
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
BLOCK DIAGRAM  
P0.0–P0.7  
P2.0–P2.7  
PORT 0  
DRIVERS  
PORT 2  
DRIVERS  
V
V
CC  
SS  
RAM ADDR  
REGISTER  
PORT 0  
LATCH  
PORT 2  
LATCH  
FLASH  
RAM  
8
B
STACK  
POINTER  
ACC  
REGISTER  
PROGRAM  
ADDRESS  
REGISTER  
TMP1  
TMP2  
BUFFER  
ALU  
SFRs  
TIMERS  
P.C.A.  
PC  
INCRE-  
MENTER  
PSW  
8
16  
PROGRAM  
COUNTER  
PSEN  
ALE  
DPTR’S  
MULTIPLE  
TIMING  
AND  
CONTROL  
EAV  
PP  
RST  
PORT 1  
LATCH  
PORT 3  
LATCH  
PD  
OSCILLATOR  
PORT 1  
DRIVERS  
PORT 3  
DRIVERS  
XTAL1  
XTAL2  
P1.0–P1.7  
P3.0–P3.7  
SU01065  
4
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
LOGIC SYMBOL  
Plastic Leaded Chip Carrier  
6
1
40  
V
V
SS  
CC  
XTAL1  
7
39  
ADDRESS AND  
DATA BUS  
LCC  
XTAL2  
RST  
17  
29  
T2  
T2EX  
18  
28  
EA/V  
PP  
Pin Function  
Pin Function  
Pin Function  
PSEN  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
NIC*  
P1.0/T2  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
P3.4/T0  
P3.5/T1  
P3.6/WR  
P3.7/RD  
XTAL2  
XTAL1  
V
SS  
NIC*  
P2.0/A8  
P2.1/A9  
P2.2/A10  
P2.3/A11  
P2.4/A12  
P2.5/A13  
P2.6/A14  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
P2.7/A15  
PSEN  
ALE/PROG  
NIC*  
ALE/PROG  
RxD  
P1.1/T2EX  
P1.2/ECI  
P1.3/CEX0  
P1.4/CEX1  
P1.5/CEX2  
P1.6/CEX3  
P1.7/CEX4  
RST  
P3.0/RxD  
NIC*  
P3.1/TxD  
P3.2/INT0  
P3.3/INT1  
TxD  
INT0  
EA/V  
PP  
INT1  
T0  
T1  
WR  
RD  
P0.7/AD7  
P0.6/AD6  
P0.5/AD5  
P0.4/AD4  
P0.3/AD3  
P0.2/AD2  
P0.1/AD1  
P0.0/AD0  
ADDRESS BUS  
SU01302  
V
CC  
* NO INTERNAL CONNECTION  
PINNING  
Plastic Dual In-Line Package  
SU00023  
Plastic Quad Flat Pack  
T2/P1.0  
40  
39  
V
CC  
1
2
3
44  
34  
T2EX/P1.1  
P0.0/AD0  
ECI/P1.2  
38 P0.1/AD1  
37 P0.2/AD2  
1
33  
23  
CEX0/P1.3  
CEX1/P1.4  
4
5
36  
P0.3/AD3  
35 P0.4/AD4  
34  
PQFP  
CEX2/P1.5  
CEX3/P1.6  
CEX4/P1.7  
RST  
6
7
8
9
11  
P0.5/AD5  
33 P0.6/AD6  
32  
12  
Pin Function  
22  
P0.7/AD7  
Pin Function  
Pin Function  
DUAL  
IN-LINE  
PACKAGE  
31 EA/V  
RxD/P3.0 10  
TxD/P3.1 11  
INT0/P3.2 12  
PP  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
P1.5/CEX2  
P1.6/CEX3  
P1.7/CEX4  
RST  
P3.0/RxD  
NIC*  
P3.1/TxD  
P3.2/INT0  
P3.3/INT1  
P3.4/T0  
P3.5/T1  
P3.6/WR  
P3.7/RD  
XTAL2  
16  
17  
18  
19  
20  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
V
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
42  
43  
44  
P0.6/AD6  
P0.5/AD5  
P0.4/AD4  
P0.3/AD3  
P0.2/AD2  
P0.1/AD1  
P0.0/AD0  
SS  
30  
NIC*  
ALE/PROG  
P2.0/A8  
P2.1/A9  
P2.2/A10  
P2.3/A11  
P2.4/A12  
P2.5/A13  
P2.6/A14  
P2.7/A15  
PSEN  
29 PSEN  
28  
13  
INT1/P3.3  
P2.7/A15  
27 P2.6/A14  
26  
T0/P3.4 14  
T1/P3.5 15  
WR/P3.6 16  
RD/P3.7 17  
XTAL2 18  
XTAL1 19  
V
CC  
P2.5/A13  
NIC*  
P1.0/T2  
P1.1/T2EX  
P1.2/ECI  
P1.3/CEX0  
P1.4/CEX1  
25 P2.4/A12  
24 P2.3/A11  
ALE/PROG  
NIC*  
EA/V  
PP  
23  
22  
P2.2/A10  
P2.1/A9  
P2.0/A8  
XTAL1  
P0.7/AD7  
SU00024  
* NO INTERNAL CONNECTION  
21  
V
20  
SS  
SU00021  
5
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
PIN DESCRIPTIONS  
PIN NUMBER  
MNEMONIC  
TYPE  
NAME AND FUNCTION  
PDIP  
20  
PLCC  
22  
PQFP  
16  
V
SS  
I
I
Ground: 0 V reference.  
V
CC  
40  
44  
38  
Power Supply: This is the power supply voltage for normal, idle, and power-down  
operation.  
P0.0–0.7  
39–32  
1–8  
43–36  
2–9  
37–30  
I/O  
Port 0: Port 0 is an open-drain, bidirectional I/O port. Port 0 pins that have 1s  
written to them float and can be used as high-impedance inputs. Port 0 is also the  
multiplexed low-order address and data bus during accesses to external program  
and data memory. In this application, it uses strong internal pull-ups when emitting 1s.  
P1.0–P1.7  
40–44,  
1–3  
I/O  
Port 1: Port 1 is an 8-bit bidirectional I/O port with internal pull-ups on all pins  
except P1.6 and P1.7 which are open drain. Port 1 pins that have 1s written to them  
are pulled high by the internal pull-ups and can be used as inputs. As inputs, port 1  
pins that are externally pulled low will source current because of the internal  
pull-ups. (See DC Electrical Characteristics: I ).  
IL  
Alternate functions for 89C51RB2/RC2/RD2 Port 1 include:  
1
2
40  
I/O  
T2 (P1.0): Timer/Counter 2 external count input/Clockout (see Programmable  
Clock-Out)  
2
3
4
5
6
7
8
3
4
5
6
7
8
9
41  
42  
43  
44  
1
I
T2EX (P1.1): Timer/Counter 2 Reload/Capture/Direction Control  
ECI (P1.2): External Clock Input to the PCA  
I
I/O  
I/O  
I/O  
I/O  
I/O  
CEX0 (P1.3): Capture/Compare External I/O for PCA module 0  
CEX1 (P1.4): Capture/Compare External I/O for PCA module 1  
CEX2 (P1.5): Capture/Compare External I/O for PCA module 2  
CEX3 (P1.6): Capture/Compare External I/O for PCA module 3  
CEX4 (P1.7): Capture/Compare External I/O for PCA module 4  
2
3
P2.0–P2.7  
21–28  
24–31  
18–25  
I/O  
Port 2: Port 2 is an 8-bit bidirectional I/O port with internal pull-ups. Port 2 pins that  
have 1s written to them are pulled high by the internal pull-ups and can be used as  
inputs. As inputs, port 2 pins that are externally being pulled low will source current  
because of the internal pull-ups. (See DC Electrical Characteristics: I ). Port 2  
IL  
emits the high-order address byte during fetches from external program memory  
and during accesses to external data memory that use 16-bit addresses (MOVX  
@DPTR). In this application, it uses strong internal pull-ups when emitting 1s.  
During accesses to external data memory that use 8-bit addresses (MOV @Ri),  
port 2 emits the contents of the P2 special function register.  
P3.0–P3.7  
10–17  
11,  
13–19  
5, 7–13  
I/O  
Port 3: Port 3 is an 8-bit bidirectional I/O port with internal pull-ups. Port 3 pins that  
have 1s written to them are pulled high by the internal pull-ups and can be used as  
inputs. As inputs, port 3 pins that are externally being pulled low will source current  
because of the pull-ups. (See DC Electrical Characteristics: I ). Port 3 also serves  
IL  
the special features of the 89C51RB2/RC2/RD2, as listed below:  
10  
11  
12  
13  
14  
15  
16  
17  
11  
13  
14  
15  
16  
17  
18  
19  
5
7
I
O
I
RxD (P3.0): Serial input port  
TxD (P3.1): Serial output port  
8
INT0 (P3.2): External interrupt  
9
I
INT1 (P3.3): External interrupt  
10  
11  
12  
13  
I
T0 (P3.4): Timer 0 external input  
I
T1 (P3.5): Timer 1 external input  
O
O
WR (P3.6): External data memory write strobe  
RD (P3.7): External data memory read strobe  
RST  
ALE  
9
10  
4
I
Reset: A high on this pin for two machine cycles while the oscillator is running,  
resets the device. An internal diffused resistor to V permits a power-on reset  
SS  
using only an external capacitor to V  
.
CC  
30  
33  
27  
O
Address Latch Enable: Output pulse for latching the low byte of the address  
during an access to external memory. In normal operation, ALE is emitted twice  
every machine cycle, and can be used for external timing or clocking. Note that one  
ALE pulse is skipped during each access to external data memory. ALE can be  
disabled by setting SFR auxiliary.0. With this bit set, ALE will be active only during a  
MOVX instruction.  
6
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
PIN NUMBER  
MNEMONIC  
TYPE  
NAME AND FUNCTION  
PDIP  
PLCC  
PQFP  
PSEN  
29  
32  
26  
O
Program Store Enable: The read strobe to external program memory. When  
executing code from the external program memory, PSEN is activated twice each  
machine cycle, except that two PSEN activations are skipped during each access  
to external data memory. PSEN is not activated during fetches from internal  
program memory.  
EA/V  
31  
35  
29  
I
External Access Enable/Programming Supply Voltage: EA must be externally  
held low to enable the device to fetch code from external program memory  
locations. If EA is held high, the device executes from internal program memory.  
The value on the EA pin is latched when RST is released and any subsequent  
changes have no effect. This pin also receives the programming supply voltage  
PP  
(V ) during Flash programming.  
PP  
XTAL1  
19  
18  
21  
20  
15  
14  
I
Crystal 1: Input to the inverting oscillator amplifier and input to the internal clock  
generator circuits.  
XTAL2  
O
Crystal 2: Output from the inverting oscillator amplifier.  
NOTE:  
To avoid “latch-up” effect at power-on, the voltage on any pin (other than V ) must not be higher than V + 0.5 V or less than V – 0.5 V.  
PP  
CC  
SS  
7
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Table 1. Special Function Registers  
DIRECT  
ADDRESS  
BIT ADDRESS, SYMBOL, OR ALTERNATIVE PORT FUNCTION  
RESET  
VALUE  
SYMBOL  
DESCRIPTION  
MSB  
E7  
LSB  
E0  
ACC*  
AUXR#  
AUXR1#  
B*  
Accumulator  
E0H  
8EH  
A2H  
F0H  
E6  
E5  
E4  
E3  
E2  
E1  
00H  
EXTRAM  
Auxiliary  
AO  
xxxxxx10B  
xxxxxxx0B  
00H  
ENBOOT  
Auxiliary 1  
B register  
GF2  
F3  
0
DPS  
F0  
F7  
F6  
F5  
F4  
F2  
F1  
CCAP0H# Module 0 Capture High  
CCAP1H# Module 1 Capture High  
CCAP2H# Module 2 Capture High  
CCAP3H# Module 3 Capture High  
CCAP4H# Module 4 Capture High  
CCAP0L# Module 0 Capture Low  
CCAP1L# Module 1 Capture Low  
CCAP2L# Module 2 Capture Low  
CCAP3L# Module 3 Capture Low  
CCAP4L# Module 4 Capture Low  
FAH  
FBH  
FCH  
FDH  
FEH  
EAH  
EBH  
ECH  
EDH  
EEH  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
xxxxxxxxB  
CCAPM0# Module 0 Mode  
CCAPM1# Module 1 Mode  
CCAPM2# Module 2 Mode  
CCAPM3# Module 3 Mode  
CCAPM4# Module 4 Mode  
DAH  
DBH  
DCH  
DDH  
DEH  
ECOM CAPP  
ECOM CAPP  
ECOM CAPP  
ECOM CAPP  
ECOM CAPP  
CAPN  
CAPN  
CAPN  
CAPN  
CAPN  
MAT  
MAT  
MAT  
MAT  
MAT  
TOG  
TOG  
TOG  
TOG  
TOG  
PWM  
PWM  
PWM  
PWM  
PWM  
ECCF  
ECCF  
ECCF  
ECCF  
ECCF  
x0000000B  
x0000000B  
x0000000B  
x0000000B  
x0000000B  
DF  
CF  
DE  
CR  
DD  
DC  
DB  
DA  
D9  
D8  
CCON*#  
CH#  
CL#  
PCA Counter Control  
PCA Counter High  
PCA Counter Low  
D8H  
F9H  
E9H  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
00x00000B  
00H  
00H  
CMOD#  
PCA Counter Mode  
D9H  
CIDL  
WDTE  
CPS1  
CPS0  
ECF  
00xxx000B  
DPTR:  
DPH  
DPL  
Data Pointer (2 bytes)  
Data Pointer High  
Data Pointer Low  
83H  
82H  
00H  
00H  
AF  
EA  
BF  
AE  
EC  
AD  
ET2  
BD  
AC  
ES  
AB  
ET1  
BB  
AA  
EX1  
BA  
A9  
ET0  
B9  
A8  
EX0  
B8  
IE*  
Interrupt Enable 0  
Interrupt Priority  
A8H  
B8H  
B7H  
00H  
BE  
BC  
PS  
IP*  
PPC  
B6  
PT2  
B5  
PT1  
B3  
PX1  
B2  
PT0  
B1  
PX0  
B0  
x0000000B  
x0000000B  
B7  
B4  
IPH#  
Interrupt Priority High  
PPCH  
PT2H  
PSH  
PT1H  
PX1H  
PT0H  
PX0H  
87  
AD7  
97  
86  
AD6  
96  
85  
AD5  
95  
84  
AD4  
94  
83  
AD3  
93  
82  
AD2  
92  
81  
AD1  
91  
80  
AD0  
90  
P0*  
P1*  
P2*  
P3*  
Port 0  
Port 1  
Port 2  
80H  
90H  
A0H  
FFH  
FFH  
FFH  
CEX4  
A7  
CEX3  
A6  
CEX2  
A5  
CEX1  
A4  
CEX0  
A3  
ECI  
A2  
T2EX  
A1  
T2  
A0  
AD15  
B7  
AD14  
B6  
AD13  
B5  
AD12  
B4  
AD11  
B3  
AD10  
B2  
AD9  
B1  
AD8  
B0  
Port 3  
B0H  
87H  
RD  
WR  
T1  
T0  
INT1  
INT0  
TxD  
RxD  
FFH  
1
PCON#  
Power Control  
SMOD1 SMOD0  
GF1  
GF0  
PD  
IDL  
00xxx000B  
*
SFRs are bit addressable.  
#
SFRs are modified from or added to the 80C51 SFRs.  
Reserved bits.  
1. Reset value depends on reset source.  
8
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Table 1. Special Function Registers (Continued)  
BIT ADDRESS, SYMBOL, OR ALTERNATIVE PORT FUNCTION  
DIRECT  
ADDRESS  
RESET  
VALUE  
SYMBOL  
DESCRIPTION  
MSB  
LSB  
D7  
CY  
D6  
AC  
D5  
F0  
D4  
D3  
D2  
D1  
F1  
D0  
P
PSW*  
Program Status Word  
D0H  
RS1  
RS0  
OV  
00000000B  
RCAP2H#  
RCAP2L#  
Timer 2 Capture High  
Timer 2 Capture Low  
CBH  
CAH  
00H  
00H  
SADDR# Slave Address  
SADEN# Slave Address Mask  
A9H  
B9H  
00H  
00H  
SBUF  
Serial Data Buffer  
99H  
xxxxxxxxB  
9F  
9E  
9D  
9C  
9B  
9A  
99  
TI  
98  
RI  
SM0/FE  
SCON*  
SP  
Serial Control  
Stack Pointer  
98H  
81H  
SM1  
SM2  
REN  
TB8  
RB8  
00H  
07H  
8F  
8E  
8D  
8C  
8B  
8A  
89  
88  
TCON*  
Timer Control  
88H  
TF1  
TR1  
TF0  
TR0  
IE1  
IT1  
IE0  
IT0  
00H  
CF  
TF2  
CE  
EXF2  
CD  
RCLK  
CC  
TCLK  
CB  
EXEN2  
CA  
TR2  
C9  
C8  
T2CON*  
Timer 2 Control  
C8H  
C9H  
C/T2  
T2OE  
CP/RL2 00H  
DCEN xxxxxx00B  
T2MOD# Timer 2 Mode Control  
TH0  
TH1  
TH2#  
TL0  
TL1  
TL2#  
Timer High 0  
Timer High 1  
Timer High 2  
Timer Low 0  
Timer Low 1  
Timer Low 2  
8CH  
8DH  
CDH  
8AH  
8BH  
CCH  
00H  
00H  
00H  
00H  
00H  
00H  
TMOD  
Timer Mode  
89H  
A6H  
GATE  
C/T  
M1  
M0  
GATE  
C/T  
M1  
M0  
00H  
WDTRST Watchdog Timer Reset  
*
SFRs are bit addressable.  
#
SFRs are modified from or added to the 80C51 SFRs.  
Reserved bits.  
OSCILLATOR CHARACTERISTICS  
RESET  
XTAL1 and XTAL2 are the input and output, respectively, of an  
inverting amplifier. The pins can be configured for use as an  
on-chip oscillator.  
A reset is accomplished by holding the RST pin high for at least two  
machine cycles (12 oscillator periods in 6 clock mode, or 24 oscillator  
periods in 12 clock mode), while the oscillator is running. To ensure a  
good power-on reset, the RST pin must be high long enough to allow  
the oscillator time to start up (normally a few milliseconds) plus two  
To drive the device from an external clock source, XTAL1 should be  
driven while XTAL2 is left unconnected. Minimum and maximum  
high and low times specified in the data sheet must be observed.  
machine cycles. At power-on, the voltage on V and RST must  
CC  
come up at the same time for a proper start-up. Ports 1, 2, and 3 will  
asynchronously be driven to their reset condition when a voltage  
This device is configured at the factory to operate using 6 clock  
periods per machine cycle, referred to in this datasheet as “6 clock  
mode”. (This yields performance equivalent to twice that of standard  
80C51 family devices). It may be optionally configured on  
commercially-available EPROM programming equipment to operate  
at 12 clocks per machine cycle, referred to in this datasheet as  
“12 clock mode”. Once 12 clock mode has been configured, it  
cannot be changed back to 6 clock mode.  
above V  
(min.) is applied to RESET.  
IH1  
The value on the EA pin is latched when RST is deasserted and has  
no further effect.  
9
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
LOW POWER MODES  
Stop Clock Mode  
Design Consideration  
The static design enables the clock speed to be reduced down to  
0 MHz (stopped). When the oscillator is stopped, the RAM and  
Special Function Registers retain their values. This mode allows  
step-by-step utilization and permits reduced system power  
consumption by lowering the clock frequency down to any value. For  
lowest power consumption the Power Down mode is suggested.  
When the idle mode is terminated by a hardware reset, the device  
normally resumes program execution, from where it left off, up to  
two machine cycles before the internal reset algorithm takes  
control. On-chip hardware inhibits access to internal RAM in this  
event, but access to the port pins is not inhibited. To eliminate the  
possibility of an unexpected write when Idle is terminated by reset,  
the instruction following the one that invokes Idle should not be  
one that writes to a port pin or to external memory.  
Idle Mode  
In the idle mode (see Table 2), the CPU puts itself to sleep while all  
of the on-chip peripherals stay active. The instruction to invoke the  
idle mode is the last instruction executed in the normal operating  
mode before the idle mode is activated. The CPU contents, the  
on-chip RAM, and all of the special function registers remain intact  
during this mode. The idle mode can be terminated either by any  
enabled interrupt (at which time the process is picked up at the  
interrupt service routine and continued), or by a hardware reset  
which starts the processor in the same manner as a power-on reset.  
ONCE Mode  
The ONCE (“On-Circuit Emulation”) Mode facilitates testing and  
debugging of systems without the device having to be removed from  
the circuit. The ONCE Mode is invoked by:  
1. Pull ALE low while the device is in reset and PSEN is high;  
2. Hold ALE low as RST is deactivated.  
While the device is in ONCE Mode, the Port 0 pins go into a float  
state, and the other port pins and ALE and PSEN are weakly pulled  
high. The oscillator circuit remains active. While the device is in this  
mode, an emulator or test CPU can be used to drive the circuit.  
Normal operation is restored when a normal reset is applied.  
Power-Down Mode  
To save even more power, a Power Down mode (see Table 2) can  
be invoked by software. In this mode, the oscillator is stopped and  
the instruction that invoked Power Down is the last instruction  
executed. The on-chip RAM and Special Function Registers retain  
Programmable Clock-Out  
A 50% duty cycle clock can be programmed to come out on P1.0.  
This pin, besides being a regular I/O pin, has two alternate  
functions. It can be programmed:  
their values down to 2.0 V and care must be taken to return V to  
CC  
the minimum specified operating voltages before the Power Down  
Mode is terminated.  
1. to input the external clock for Timer/Counter 2, or  
Either a hardware reset or external interrupt can be used to exit from  
Power Down. Reset redefines all the SFRs but does not change the  
on-chip RAM. An external interrupt allows both the SFRs and the  
on-chip RAM to retain their values.  
2. to output a 50% duty cycle clock ranging from 122 Hz to 8 MHz at  
a 16 MHz operating frequency (61 Hz to 4 MHz in 12 clock mode).  
To configure the Timer/Counter 2 as a clock generator, bit C/T2 (in  
T2CON) must be cleared and bit T20E in T2MOD must be set. Bit  
TR2 (T2CON.2) also must be set to start the timer.  
To properly terminate Power Down, the reset or external interrupt  
should not be executed before V is restored to its normal  
CC  
operating level and must be held active long enough for the  
oscillator to restart and stabilize (normally less than 10 ms).  
The Clock-Out frequency depends on the oscillator frequency and  
the reload value of Timer 2 capture registers (RCAP2H, RCAP2L)  
as shown in this equation:  
With an external interrupt, INT0 and INT1 must be enabled and  
configured as level-sensitive. Holding the pin low restarts the oscillator  
but bringing the pin back high completes the exit. Once the interrupt  
is serviced, the next instruction to be executed after RETI will be the  
one following the instruction that put the device into Power Down.  
Oscillator Frequency  
n   (65536 * RCAP2H, RCAP2L)  
n =  
2 in 6 clock mode  
4 in 12 clock mode  
POWER OFF FLAG  
The Power Off Flag (POF) is set by on-chip circuitry when the V  
Where (RCAP2H,RCAP2L) = the content of RCAP2H and RCAP2L  
taken as a 16-bit unsigned integer.  
CC  
level on the 89C51RB2/RC2/RD2 rises from 0 to 5 V. The POF bit  
can be set or cleared by software allowing a user to determine if the  
reset is the result of a power-on or a warm start after powerdown.  
In the Clock-Out mode Timer 2 roll-overs will not generate an  
interrupt. This is similar to when it is used as a baud-rate generator.  
It is possible to use Timer 2 as a baud-rate generator and a clock  
generator simultaneously. Note, however, that the baud-rate and the  
Clock-Out frequency will be the same.  
The V level must remain above 3 V for the POF to remain  
CC  
unaffected by the V level.  
CC  
Table 2. External Pin Status During Idle and Power-Down Mode  
MODE  
PROGRAM MEMORY  
Internal  
ALE  
PSEN  
PORT 0  
Data  
PORT 1  
Data  
PORT 2  
Data  
PORT 3  
Data  
Idle  
Idle  
1
1
0
0
1
1
0
0
External  
Float  
Data  
Address  
Data  
Data  
Power-down  
Power-down  
Internal  
Data  
Data  
Data  
External  
Float  
Data  
Data  
Data  
10  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Counter Enable) which is located in the T2MOD register (see  
Figure 3). When reset is applied the DCEN=0 which means Timer 2  
will default to counting up. If DCEN bit is set, Timer 2 can count up  
or down depending on the value of the T2EX pin.  
TIMER 2 OPERATION  
Timer 2  
Timer 2 is a 16-bit Timer/Counter which can operate as either an  
event timer or an event counter, as selected by C/T2* in the special  
function register T2CON (see Figure 1). Timer 2 has three operating  
modes: Capture, Auto-reload (up or down counting), and Baud Rate  
Generator, which are selected by bits in the T2CON as shown in  
Table 3.  
Figure 4 shows Timer 2 which will count up automatically since  
DCEN=0. In this mode there are two options selected by bit EXEN2  
in T2CON register. If EXEN2=0, then Timer 2 counts up to 0FFFFH  
and sets the TF2 (Overflow Flag) bit upon overflow. This causes the  
Timer 2 registers to be reloaded with the 16-bit value in RCAP2L  
and RCAP2H. The values in RCAP2L and RCAP2H are preset by  
software means.  
Capture Mode  
In the capture mode there are two options which are selected by bit  
EXEN2 in T2CON. If EXEN2=0, then timer 2 is a 16-bit timer or  
counter (as selected by C/T2* in T2CON) which, upon overflowing  
sets bit TF2, the timer 2 overflow bit. This bit can be used to  
generate an interrupt (by enabling the Timer 2 interrupt bit in the  
IE register). If EXEN2= 1, Timer 2 operates as described above, but  
with the added feature that a 1- to -0 transition at external input  
T2EX causes the current value in the Timer 2 registers, TL2 and  
TH2, to be captured into registers RCAP2L and RCAP2H,  
respectively. In addition, the transition at T2EX causes bit EXF2 in  
T2CON to be set, and EXF2 like TF2 can generate an interrupt  
(which vectors to the same location as Timer 2 overflow interrupt.  
The Timer 2 interrupt service routine can interrogate TF2 and EXF2  
to determine which event caused the interrupt). The capture mode is  
illustrated in Figure 2 (There is no reload value for TL2 and TH2 in  
this mode. Even when a capture event occurs from T2EX, the  
counter keeps on counting T2EX pin transitions or osc/6 pulses  
(osc/12 in 12 clock mode).).  
If EXEN2=1, then a 16-bit reload can be triggered either by an  
overflow or by a 1-to-0 transition at input T2EX. This transition also  
sets the EXF2 bit. The Timer 2 interrupt, if enabled, can be  
generated when either TF2 or EXF2 are 1.  
In Figure 5 DCEN=1 which enables Timer 2 to count up or down.  
This mode allows pin T2EX to control the direction of count. When a  
logic 1 is applied at pin T2EX Timer 2 will count up. Timer 2 will  
overflow at 0FFFFH and set the TF2 flag, which can then generate  
an interrupt, if the interrupt is enabled. This timer overflow also  
causes the 16-bit value in RCAP2L and RCAP2H to be reloaded  
into the timer registers TL2 and TH2.  
When a logic 0 is applied at pin T2EX this causes Timer 2 to count  
down. The timer will underflow when TL2 and TH2 become equal to  
the value stored in RCAP2L and RCAP2H. Timer 2 underflow sets  
the TF2 flag and causes 0FFFFH to be reloaded into the timer  
registers TL2 and TH2.  
Auto-Reload Mode (Up or Down Counter)  
The external flag EXF2 toggles when Timer 2 underflows or overflows.  
This EXF2 bit can be used as a 17th bit of resolution if needed. The  
EXF2 flag does not generate an interrupt in this mode of operation.  
In the 16-bit auto-reload mode, Timer 2 can be configured (as either  
a timer or counter [C/T2* in T2CON]) then programmed to count up  
or down. The counting direction is determined by bit DCEN (Down  
(MSB)  
(LSB)  
TF2  
EXF2  
RCLK  
TCLK  
EXEN2  
TR2  
C/T2  
CP/RL2  
Symbol  
Position  
Name and Significance  
TF2  
T2CON.7  
T2CON.6  
Timer 2 overflow flag set by a Timer 2 overflow and must be cleared by software. TF2 will not be set  
when either RCLK or TCLK = 1.  
EXF2  
Timer 2 external flag set when either a capture or reload is caused by a negative transition on T2EX and  
EXEN2 = 1. When Timer 2 interrupt is enabled, EXF2 = 1 will cause the CPU to vector to the Timer 2  
interrupt routine. EXF2 must be cleared by software. EXF2 does not cause an interrupt in up/down  
counter mode (DCEN = 1).  
RCLK  
TCLK  
T2CON.5  
T2CON.4  
T2CON.3  
Receive clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its receive clock  
in modes 1 and 3. RCLK = 0 causes Timer 1 overflow to be used for the receive clock.  
Transmit clock flag. When set, causes the serial port to use Timer 2 overflow pulses for its transmit clock  
in modes 1 and 3. TCLK = 0 causes Timer 1 overflows to be used for the transmit clock.  
EXEN2  
Timer 2 external enable flag. When set, allows a capture or reload to occur as a result of a negative  
transition on T2EX if Timer 2 is not being used to clock the serial port. EXEN2 = 0 causes Timer 2 to  
ignore events at T2EX.  
TR2  
T2CON.2  
T2CON.1  
Start/stop control for Timer 2. A logic 1 starts the timer.  
C/T2  
Timer or counter select. (Timer 2)  
0 = Internal timer (OSC/6 in 6 clock mode or OSC/12 in 12 clock mode)  
1 = External event counter (falling edge triggered).  
CP/RL2  
T2CON.0  
Capture/Reload flag. When set, captures will occur on negative transitions at T2EX if EXEN2 = 1. When  
cleared, auto-reloads will occur either with Timer 2 overflows or negative transitions at T2EX when  
EXEN2 = 1. When either RCLK = 1 or TCLK = 1, this bit is ignored and the timer is forced to auto-reload  
on Timer 2 overflow.  
SU01251  
Figure 1. Timer/Counter 2 (T2CON) Control Register  
11  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Table 3. Timer 2 Operating Modes  
RCLK + TCLK  
CP/RL2  
TR2  
1
MODE  
0
0
1
X
0
1
16-bit Auto-reload  
1
16-bit Capture  
Baud rate generator  
(off)  
X
X
1
0
OSC  
÷ n*  
C/T2 = 0  
TL2  
(8-bits)  
TH2  
(8-bits)  
TF2  
C/T2 = 1  
T2 Pin  
Control  
TR2  
Capture  
Transition  
Detector  
Timer 2  
Interrupt  
RCAP2L  
RCAP2H  
T2EX Pin  
EXF2  
Control  
EXEN2  
SU01252  
* n = 6 in 6 clock mode, or 12 in 12 clock mode.  
Figure 2. Timer 2 in Capture Mode  
T2MOD  
Address = 0C9H  
Not Bit Addressable  
Reset Value = XXXX XX00B  
6
5
4
3
2
T2OE  
1
DCEN  
0
Bit  
7
Symbol  
Function  
Not implemented, reserved for future use.*  
Timer 2 Output Enable bit.  
T2OE  
DCEN  
Down Count Enable bit. When set, this allows Timer 2 to be configured as an up/down counter.  
*
User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features.  
In that case, the reset or inactive value of the new bit will be 0, and its active value will be 1. The value read from a reserved bit is  
indeterminate.  
SU00729  
Figure 3. Timer 2 Mode (T2MOD) Control Register  
12  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
OSC  
÷ n*  
C/T2 = 0  
TL2  
(8-BITS)  
TH2  
(8-BITS)  
C/T2 = 1  
T2 PIN  
CONTROL  
TR2  
RELOAD  
TRANSITION  
DETECTOR  
RCAP2L  
RCAP2H  
TF2  
TIMER 2  
INTERRUPT  
T2EX PIN  
EXF2  
CONTROL  
EXEN2  
SU01253  
* n = 6 in 6 clock mode, or 12 in 12 clock mode.  
Figure 4. Timer 2 in Auto-Reload Mode (DCEN = 0)  
(DOWN COUNTING RELOAD VALUE)  
FFH  
FFH  
TOGGLE  
EXF2  
÷ n*  
OSC  
C/T2 = 0  
C/T2 = 1  
OVERFLOW  
TL2  
TH2  
TF2  
INTERRUPT  
T2 PIN  
CONTROL  
TR2  
COUNT  
DIRECTION  
1 = UP  
0 = DOWN  
RCAP2L  
RCAP2H  
(UP COUNTING RELOAD VALUE)  
T2EX PIN  
* n = 6 in 6 clock mode, or 12 in 12 clock mode.  
SU01254  
Figure 5. Timer 2 Auto Reload Mode (DCEN = 1)  
13  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Timer 1  
Overflow  
÷ 2  
“0”  
“0”  
“1”  
OSC  
C/T2 = 0  
SMOD  
RCLK  
“1”  
TL2  
(8-bits)  
TH2  
(8-bits)  
C/T2 = 1  
T2 Pin  
Control  
RX Clock  
÷ 16  
÷ 16  
“1”  
“0”  
TR2  
Reload  
TCLK  
Transition  
Detector  
RCAP2L  
RCAP2H  
TX Clock  
Timer 2  
Interrupt  
T2EX Pin  
EXF2  
Control  
EXEN2  
Note availability of additional external interrupt.  
SU01213  
Figure 6. Timer 2 in Baud Rate Generator Mode  
The baud rates in modes 1 and 3 are determined by Timer 2’s  
overflow rate given below:  
Table 4. Timer 2 Generated Commonly Used  
Baud Rates  
Timer 2 Overflow Rate  
Modes 1 and 3 Baud Rates +  
Baud Rate  
Timer 2  
16  
Osc Freq  
12 clock  
mode  
6 clock  
mode  
The timer can be configured for either “timer” or “counter” operation.  
In many applications, it is configured for “timer” operation (C/T2*=0).  
Timer operation is different for Timer 2 when it is being used as a  
baud rate generator.  
RCAP2H  
RCAP2L  
375 k  
9.6 k  
2.8 k  
2.4 k  
1.2 k  
300  
110  
300  
110  
750 k  
19.2 k  
5.6 k  
4.8 k  
2.4 k  
600  
220  
600  
220  
12 MHz  
12 MHz  
12 MHz  
12 MHz  
12 MHz  
12 MHz  
12 MHz  
6 MHz  
FF  
FF  
FF  
FF  
FE  
FB  
F2  
FD  
F9  
FF  
D9  
B2  
64  
C8  
1E  
AF  
8F  
57  
Usually, as a timer it would increment every machine cycle (i.e.,  
1
1
/ the oscillator frequency in 6 clock mode, / the oscillator  
6
12  
frequency in 12 clock mode). As a baud rate generator, it increments  
OSC  
at the oscillator frequency in 6 clock mode (  
Thus the baud rate formula is as follows:  
/ in 12 clock mode).  
2
Modes 1 and 3 Baud Rates =  
Oscillator Frequency  
6 MHz  
[ n *   [65536 * (RCAP2H, RCAP2L)]]  
Baud Rate Generator Mode  
* n =  
16 in 6 clock mode  
32 in 12 clock mode  
Bits TCLK and/or RCLK in T2CON (Table 4) allow the serial port  
transmit and receive baud rates to be derived from either Timer 1 or  
Timer 2. When TCLK= 0, Timer 1 is used as the serial port transmit  
baud rate generator. When TCLK= 1, Timer 2 is used as the serial  
port transmit baud rate generator. RCLK has the same effect for the  
serial port receive baud rate. With these two bits, the serial port can  
have different receive and transmit baud rates – one generated by  
Timer 1, the other by Timer 2.  
Where: (RCAP2H, RCAP2L)= The content of RCAP2H and  
RCAP2L taken as a 16-bit unsigned integer.  
The Timer 2 as a baud rate generator mode shown in Figure 6, is  
valid only if RCLK and/or TCLK = 1 in T2CON register. Note that a  
rollover in TH2 does not set TF2, and will not generate an interrupt.  
Thus, the Timer 2 interrupt does not have to be disabled when  
Timer 2 is in the baud rate generator mode. Also if the EXEN2  
(T2 external enable flag) is set, a 1-to-0 transition in T2EX  
(Timer/counter 2 trigger input) will set EXF2 (T2 external flag) but  
will not cause a reload from (RCAP2H, RCAP2L) to (TH2,TL2).  
Therefore when Timer 2 is in use as a baud rate generator, T2EX  
can be used as an additional external interrupt, if needed.  
Figure 6 shows the Timer 2 in baud rate generation mode. The baud  
rate generation mode is like the auto-reload mode,in that a rollover in  
TH2 causes the Timer 2 registers to be reloaded with the 16-bit value  
in registers RCAP2H and RCAP2L, which are preset by software.  
14  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
When Timer 2 is in the baud rate generator mode, one should not try  
to read or write TH2 and TL2. As a baud rate generator, Timer 2 is  
incremented every state time (osc/2) or asynchronously from pin T2;  
under these conditions, a read or write of TH2 or TL2 may not be  
accurate. The RCAP2 registers may be read, but should not be  
written to, because a write might overlap a reload and cause write  
and/or reload errors. The timer should be turned off (clear TR2)  
before accessing the Timer 2 or RCAP2 registers.  
If Timer 2 is being clocked internally, the baud rate is:  
fOSC  
Baud Rate +  
[ n *   [65536 * (RCAP2H, RCAP2L)]]  
* n =  
16 in 6 clock mode  
32 in 12 clock mode  
Where f  
= Oscillator Frequency  
OSC  
To obtain the reload value for RCAP2H and RCAP2L, the above  
equation can be rewritten as:  
Table 4 shows commonly used baud rates and how they can be  
obtained from Timer 2.  
fOSC  
Summary of Baud Rate Equations  
Timer 2 is in baud rate generating mode. If Timer 2 is being clocked  
through pin T2(P1.0) the baud rate is:  
RCAP2H, RCAP2L + 65536 * ǒ  
Ǔ
n *   Baud Rate  
Timer/Counter 2 Set-up  
Timer 2 Overflow Rate  
Baud Rate +  
Except for the baud rate generator mode, the values given for T2CON  
do not include the setting of the TR2 bit. Therefore, bit TR2 must be  
set, separately, to turn the timer on. see Table 5 for set-up of Timer 2  
as a timer. Also see Table 6 for set-up of Timer 2 as a counter.  
16  
Table 5. Timer 2 as a Timer  
T2CON  
MODE  
INTERNAL CONTROL  
(Note 1)  
EXTERNAL CONTROL  
(Note 2)  
16-bit Auto-Reload  
00H  
01H  
34H  
24H  
14H  
08H  
09H  
36H  
26H  
16H  
16-bit Capture  
Baud rate generator receive and transmit same baud rate  
Receive only  
Transmit only  
Table 6. Timer 2 as a Counter  
TMOD  
MODE  
INTERNAL CONTROL  
(Note 1)  
EXTERNAL CONTROL  
(Note 2)  
16-bit  
02H  
03H  
0AH  
0BH  
Auto-Reload  
NOTES:  
1. Capture/reload occurs only on timer/counter overflow.  
2. Capture/reload occurs on timer/counter overflow and a 1-to-0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate  
generator mode.  
15  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Slave 1  
SADDR  
SADEN  
Given  
=
=
=
1100 0000  
1111 1110  
1100 000X  
Enhanced UART  
The UART operates in all of the usual modes that are described in  
the first section of Data Handbook IC20, 80C51-Based 8-Bit  
Microcontrollers. In addition the UART can perform framing error  
In the above example SADDR is the same and the SADEN data is  
used to differentiate between the two slaves. Slave 0 requires a 0 in  
bit 0 and it ignores bit 1. Slave 1 requires a 0 in bit 1 and bit 0 is  
ignored. A unique address for Slave 0 would be 1100 0010 since  
slave 1 requires a 0 in bit 1. A unique address for slave 1 would be  
1100 0001 since a 1 in bit 0 will exclude slave 0. Both slaves can be  
selected at the same time by an address which has bit 0 = 0 (for  
slave 0) and bit 1 = 0 (for slave 1). Thus, both could be addressed  
with 1100 0000.  
detect by looking for missing stop bits, and automatic address  
recognition. The UART also fully supports multiprocessor  
communication as does the standard 80C51 UART.  
When used for framing error detect the UART looks for missing stop  
bits in the communication. A missing bit will set the FE bit in the  
SCON register. The FE bit shares the SCON.7 bit with SM0 and the  
function of SCON.7 is determined by PCON.6 (SMOD0) (see  
Figure 7). If SMOD0 is set then SCON.7 functions as FE. SCON.7  
functions as SM0 when SMOD0 is cleared. When used as FE  
SCON.7 can only be cleared by software. Refer to Figure 8.  
In a more complex system the following could be used to select  
slaves 1 and 2 while excluding slave 0:  
Automatic Address Recognition  
Slave 0  
Slave 1  
Slave 2  
SADDR  
SADEN  
Given  
=
=
=
1100 0000  
1111 1001  
1100 0XX0  
Automatic Address Recognition is a feature which allows the UART  
to recognize certain addresses in the serial bit stream by using  
hardware to make the comparisons. This feature saves a great deal  
of software overhead by eliminating the need for the software to  
examine every serial address which passes by the serial port. This  
feature is enabled by setting the SM2 bit in SCON. In the 9 bit UART  
modes, mode 2 and mode 3, the Receive Interrupt flag (RI) will be  
automatically set when the received byte contains either the “Given”  
address or the “Broadcast” address. The 9-bit mode requires that  
the 9th information bit is a 1 to indicate that the received information  
is an address and not data. Automatic address recognition is shown  
in Figure 9.  
SADDR  
SADEN  
Given  
=
=
=
1110 0000  
1111 1010  
1110 0X0X  
SADDR  
SADEN  
Given  
=
=
=
1110 0000  
1111 1100  
1110 00XX  
In the above example the differentiation among the 3 slaves is in the  
lower 3 address bits. Slave 0 requires that bit 0 = 0 and it can be  
uniquely addressed by 1110 0110. Slave 1 requires that bit 1 = 0 and  
it can be uniquely addressed by 1110 and 0101. Slave 2 requires  
that bit 2 = 0 and its unique address is 1110 0011. To select Slaves 0  
and 1 and exclude Slave 2 use address 1110 0100, since it is  
necessary to make bit 2 = 1 to exclude slave 2.  
The 8 bit mode is called Mode 1. In this mode the RI flag will be set  
if SM2 is enabled and the information received has a valid stop bit  
following the 8 address bits and the information is either a Given or  
Broadcast address.  
Mode 0 is the Shift Register mode and SM2 is ignored.  
The Broadcast Address for each slave is created by taking the  
logical OR of SADDR and SADEN. Zeros in this result are trended  
as don’t-cares. In most cases, interpreting the don’t-cares as ones,  
the broadcast address will be FF hexadecimal.  
Using the Automatic Address Recognition feature allows a master to  
selectively communicate with one or more slaves by invoking the  
Given slave address or addresses. All of the slaves may be  
contacted by using the Broadcast address. Two special Function  
Registers are used to define the slave’s address, SADDR, and the  
address mask, SADEN. SADEN is used to define which bits in the  
SADDR are to b used and which bits are “don’t care”. The SADEN  
mask can be logically ANDed with the SADDR to create the “Given”  
address which the master will use for addressing each of the slaves.  
Use of the Given address allows multiple slaves to be recognized  
while excluding others. The following examples will help to show the  
versatility of this scheme:  
Upon reset SADDR (SFR address 0A9H) and SADEN (SFR  
address 0B9H) are leaded with 0s. This produces a given address  
of all “don’t cares” as well as a Broadcast address of all “don’t  
cares”. This effectively disables the Automatic Addressing mode and  
allows the microcontroller to use standard 80C51 type UART drivers  
which do not make use of this feature.  
Slave 0  
SADDR  
SADEN  
Given  
=
=
=
1100 0000  
1111 1101  
1100 00X0  
16  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
SCON Address = 98H  
Reset Value = 0000 0000B  
Bit Addressable  
SM0/FE  
SM1  
SM2  
REN  
TB8  
RB8  
Tl  
Rl  
Bit:  
7
6
5
4
3
2
1
0
(SMOD0 = 0/1)*  
Symbol  
FE  
Function  
Framing Error bit. This bit is set by the receiver when an invalid stop bit is detected. The FE bit is not cleared by valid  
frames but should be cleared by software. The SMOD0 bit must be set to enable access to the FE bit.  
SM0  
SM1  
Serial Port Mode Bit 0, (SMOD0 must = 0 to access bit SM0)  
Serial Port Mode Bit 1  
SM0  
SM1  
Mode  
Description  
Baud Rate**  
0
0
1
0
1
0
0
1
2
shift register  
8-bit UART  
9-bit UART  
f
/6 (6 clock mode) or f  
/12 (12 clock mode)  
OSC  
OSC  
variable  
f
f
/32 or f  
/64 or f  
/16 (6 clock mode) or  
/32 (12 clock mode)  
OSC  
OSC  
OSC  
OSC  
1
1
3
9-bit UART  
variable  
SM2  
Enables the Automatic Address Recognition feature in Modes 2 or 3. If SM2 = 1 then Rl will not be set unless the  
received 9th data bit (RB8) is 1, indicating an address, and the received byte is a Given or Broadcast Address.  
In Mode 1, if SM2 = 1 then Rl will not be activated unless a valid stop bit was received, and the received byte is a  
Given or Broadcast Address. In Mode 0, SM2 should be 0.  
REN  
TB8  
RB8  
Enables serial reception. Set by software to enable reception. Clear by software to disable reception.  
The 9th data bit that will be transmitted in Modes 2 and 3. Set or clear by software as desired.  
In modes 2 and 3, the 9th data bit that was received. In Mode 1, if SM2 = 0, RB8 is the stop bit that was received.  
In Mode 0, RB8 is not used.  
Tl  
Transmit interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or at the beginning of the stop bit in the  
other modes, in any serial transmission. Must be cleared by software.  
Rl  
Receive interrupt flag. Set by hardware at the end of the 8th bit time in Mode 0, or halfway through the stop bit time in  
the other modes, in any serial reception (except see SM2). Must be cleared by software.  
NOTE:  
*SMOD0 is located at PCON6.  
**f = oscillator frequency  
OSC  
SU01255  
Figure 7. SCON: Serial Port Control Register  
17  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
START  
BIT  
DATA BYTE  
ONLY IN  
MODE 2, 3  
STOP  
BIT  
SET FE BIT IF STOP BIT IS 0 (FRAMING ERROR)  
SM0 TO UART MODE CONTROL  
SCON  
(98H)  
SM0 / FE  
SMOD1  
SM1  
SM2  
REN  
POF  
TB8  
LVF  
RB8  
GF0  
TI  
RI  
PCON  
(87H)  
SMOD0  
GF1  
IDL  
0 : SCON.7 = SM0  
1 : SCON.7 = FE  
SU00044  
Figure 8. UART Framing Error Detection  
D0  
D1  
D2  
D3  
D4  
D5  
D6  
D7  
D8  
SCON  
(98H)  
SM0  
SM1  
SM2  
REN  
1
TB8  
X
RB8  
TI  
RI  
1
1
1
0
1
RECEIVED ADDRESS D0 TO D7  
PROGRAMMED ADDRESS  
COMPARATOR  
IN UART MODE 2 OR MODE 3 AND SM2 = 1:  
INTERRUPT IF REN=1, RB8=1 AND “RECEIVED ADDRESS” = “PROGRAMMED ADDRESS”  
– WHEN OWN ADDRESS RECEIVED, CLEAR SM2 TO RECEIVE DATA BYTES  
– WHEN ALL DATA BYTES HAVE BEEN RECEIVED: SET SM2 TO WAIT FOR NEXT ADDRESS.  
SU00045  
Figure 9. UART Multiprocessor Communication, Automatic Address Recognition  
18  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
The priority scheme for servicing the interrupts is the same as that  
for the 80C51, except there are four interrupt levels rather than two  
as on the 80C51. An interrupt will be serviced as long as an interrupt  
of equal or higher priority is not already being serviced. If an  
interrupt of equal or higher level priority is being serviced, the new  
interrupt will wait until it is finished before being serviced. If a lower  
priority level interrupt is being serviced, it will be stopped and the  
new interrupt serviced. When the new interrupt is finished, the lower  
priority level interrupt that was stopped will be completed.  
Interrupt Priority Structure  
The 89C51RB2/RC2/RD2 has an 8 source four-level interrupt  
structure (see Table 7).  
There are 3 SFRs associated with the four-level interrupt. They are  
the IE, IP, and IPH. (See Figures 10, 11, and 12.) The IPH (Interrupt  
Priority High) register makes the four-level interrupt structure  
possible. The IPH is located at SFR address B7H. The structure of  
the IPH register and a description of its bits is shown in Figure 12.  
The function of the IPH SFR is simple and when combined with the  
IP SFR determines the priority of each interrupt. The priority of each  
interrupt is determined as shown in the following table:  
PRIORITY BITS  
INTERRUPT PRIORITY LEVEL  
IPH.x  
IP.x  
0
0
0
1
1
Level 0 (lowest priority)  
Level 1  
1
0
Level 2  
1
Level 3 (highest priority)  
Table 7.  
Interrupt Table  
SOURCE  
POLLING PRIORITY  
REQUEST BITS  
HARDWARE CLEAR?  
VECTOR ADDRESS  
1
2
X0  
T0  
1
2
3
4
5
IE0  
TP0  
IE1  
N (L) Y (T)  
03H  
0BH  
13H  
1BH  
33H  
Y
X1  
N (L) Y (T)  
T1  
TF1  
Y
N
PCA  
CF, CCFn  
n = 0–4  
SP  
T2  
6
7
RI, TI  
N
N
23H  
2BH  
TF2, EXF2  
NOTES:  
1. L = Level activated  
2. T = Transition activated  
7
6
5
4
3
2
1
0
IE (0A8H)  
EA  
EC  
ET2  
ES  
ET1  
EX1  
ET0  
EX0  
Enable Bit = 1 enables the interrupt.  
Enable Bit = 0 disables it.  
BIT  
SYMBOL FUNCTION  
IE.7  
EA  
Global disable bit. If EA = 0, all interrupts are disabled. If EA = 1, each interrupt can be individually  
enabled or disabled by setting or clearing its enable bit.  
PCA interrupt enable bit  
Timer 2 interrupt enable bit.  
Serial Port interrupt enable bit.  
Timer 1 interrupt enable bit.  
External interrupt 1 enable bit.  
Timer 0 interrupt enable bit.  
IE.6  
IE.5  
IE.4  
IE.3  
IE.2  
IE.1  
IE.0  
EC  
ET2  
ES  
ET1  
EX1  
ET0  
EX0  
External interrupt 0 enable bit.  
SU01290  
Figure 10. IE Registers  
19  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
7
6
5
4
3
2
1
0
IP (0B8H)  
PPC  
PT2  
PS  
PT1  
PX1  
PT0  
PX0  
Priority Bit = 1 assigns high priority  
Priority Bit = 0 assigns low priority  
BIT  
IP.7  
IP.6  
IP.5  
IP.4  
IP.3  
IP.2  
IP.1  
IP.0  
SYMBOL FUNCTION  
PPC  
PT2  
PS  
PT1  
PX1  
PT0  
PX0  
PCA interrupt priority bit  
Timer 2 interrupt priority bit.  
Serial Port interrupt priority bit.  
Timer 1 interrupt priority bit.  
External interrupt 1 priority bit.  
Timer 0 interrupt priority bit.  
External interrupt 0 priority bit.  
SU01291  
Figure 11. IP Registers  
7
6
5
4
3
2
1
0
IPH (B7H)  
PPCH  
PT2H  
PSH  
PT1H  
PX1H  
PT0H  
PX0H  
Priority Bit = 1 assigns higher priority  
Priority Bit = 0 assigns lower priority  
BIT  
SYMBOL FUNCTION  
IPH.7  
IPH.6  
IPH.5  
IPH.4  
IPH.3  
IPH.2  
IPH.1  
IPH.0  
PPCH  
PT2H  
PSH  
PT1H  
PX1H  
PT0H  
PX0H  
PCA interrupt priority bit  
Timer 2 interrupt priority bit high.  
Serial Port interrupt priority bit high.  
Timer 1 interrupt priority bit high.  
External interrupt 1 priority bit high.  
Timer 0 interrupt priority bit high.  
External interrupt 0 priority bit high.  
SU01292  
Figure 12. IPH Registers  
20  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
be quickly toggled simply by executing an INC AUXR1 instruction  
without affecting the GF2 bit.  
Reduced EMI Mode  
The AO bit (AUXR.0) in the AUXR register when set disables the  
ALE output.  
The ENBOOT bit determines whether the BOOTROM is enabled  
or disabled. This bit will automatically be set if the status byte is  
non zero during reset or PSEN is pulled low, ALE floats high, and  
Reduced EMI Mode  
EA > V on the falling edge of reset. Otherwise, this bit will be  
cleared during reset.  
IH  
AUXR (8EH)  
7
6
5
4
3
2
1
0
EXTRAM  
AO  
AUXR.1  
AUXR.0  
EXTRAM  
AO  
DPS  
BIT0  
Turns off ALE output.  
AUXR1  
DPTR1  
DPTR0  
Dual DPTR  
DPH  
DPL  
The dual DPTR structure (see Figure 13) is a way by which the chip  
will specify the address of an external data memory location. There  
are two 16-bit DPTR registers that address the external memory,  
and a single bit called DPS = AUXR1/bit0 that allows the program  
code to switch between them.  
(83H)  
(82H)  
EXTERNAL  
DATA  
MEMORY  
SU00745A  
Figure 13.  
New Register Name: AUXR1#  
SFR Address: A2H  
DPTR Instructions  
Reset Value: xxxxxxx0B  
The instructions that refer to DPTR refer to the data pointer that is  
currently selected using the AUXR1/bit 0 register. The six  
instructions that use the DPTR are as follows:  
AUXR1 (A2H)  
7
6
5
4
3
2
0
1
0
INC DPTR  
Increments the data pointer by 1  
ENBOOT  
GF2  
DPS  
MOV DPTR, #data16 Loads the DPTR with a 16-bit constant  
Where:  
DPS = AUXR1/bit0 = Switches between DPTR0 and DPTR1.  
MOV A, @ A+DPTR  
MOVX A, @ DPTR  
Move code byte relative to DPTR to ACC  
Move external RAM (16-bit address) to  
ACC  
Select Reg  
DPS  
DPTR0  
DPTR1  
0
1
MOVX @ DPTR , A  
JMP @ A + DPTR  
Move ACC to external RAM (16-bit  
address)  
Jump indirect relative to DPTR  
The DPS bit status should be saved by software when switching  
between DPTR0 and DPTR1.  
The data pointer can be accessed on a byte-by-byte basis by  
specifying the low or high byte in an instruction which accesses the  
SFRs. See Application Note AN458 for more details.  
The GF2 bit is a general purpose user-defined flag. Note that bit 2 is  
not writable and is always read as a zero. This allows the DPS bit to  
21  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
the PCA counter overflows and an interrupt will be generated if the  
ECF bit in the CMOD register is set, The CF bit can only be cleared  
by software. Bits 0 through 4 of the CCON register are the flags for  
the modules (bit 0 for module 0, bit 1 for module 1, etc.) and are set  
by hardware when either a match or a capture occurs. These flags  
also can only be cleared by software. The PCA interrupt system  
shown in Figure 16.  
Programmable Counter Array (PCA)  
The Programmable Counter Array available on the  
89C51RB2/RC2/RD2 is a special 16-bit Timer that has five 16-bit  
capture/compare modules associated with it. Each of the modules  
can be programmed to operate in one of four modes: rising and/or  
falling edge capture, software timer, high-speed output, or pulse  
width modulator. Each module has a pin associated with it in port 1.  
Module 0 is connected to P1.3(CEX0), module 1 to P1.4(CEX1), etc.  
The basic PCA configuration is shown in Figure 14.  
Each module in the PCA has a special function register associated  
with it. These registers are: CCAPM0 for module 0, CCAPM1 for  
module 1, etc. (see Figure 19). The registers contain the bits that  
control the mode that each module will operate in. The ECCF bit  
(CCAPMn.0 where n=0, 1, 2, 3, or 4 depending on the module)  
enables the CCF flag in the CCON SFR to generate an interrupt  
when a match or compare occurs in the associated module. PWM  
(CCAPMn.1) enables the pulse width modulation mode. The TOG  
bit (CCAPMn.2) when set causes the CEX output associated with  
the module to toggle when there is a match between the PCA  
counter and the module’s capture/compare register. The match bit  
MAT (CCAPMn.3) when set will cause the CCFn bit in the CCON  
register to be set when there is a match between the PCA counter  
and the module’s capture/compare register.  
The PCA timer is a common time base for all five modules and can  
be programmed to run at: 1/6 the oscillator frequency, 1/2 the  
oscillator frequency, the Timer 0 overflow, or the input on the ECI pin  
(P1.2). The timer count source is determined from the CPS1 and  
CPS0 bits in the CMOD SFR as follows (see Figure 17):  
CPS1 CPS0 PCA Timer Count Source  
0
0
1/6 oscillator frequency (6 clock mode);  
1/12 oscillator frequency (12 clock mode)  
1/2 oscillator frequency (6 clock mode);  
1/4 oscillator frequency (12 clock mode)  
Timer 0 overflow  
0
1
1
1
0
1
External Input at ECI pin  
The next two bits CAPN (CCAPMn.4) and CAPP (CCAPMn.5)  
determine the edge that a capture input will be active on. The CAPN  
bit enables the negative edge, and the CAPP bit enables the positive  
edge. If both bits are set both edges will be enabled and a capture will  
occur for either transition. The last bit in the register ECOM  
(CCAPMn.6) when set enables the comparator function. Figure 20  
shows the CCAPMn settings for the various PCA functions.  
In the CMOD SFR are three additional bits associated with the PCA.  
They are CIDL which allows the PCA to stop during idle mode,  
WDTE which enables or disables the watchdog function on  
module 4, and ECF which when set causes an interrupt and the  
PCA overflow flag CF (in the CCON SFR) to be set when the PCA  
timer overflows. These functions are shown in Figure 15.  
The watchdog timer function is implemented in module 4 (see  
Figure 24).  
There are two additional registers associated with each of the PCA  
modules. They are CCAPnH and CCAPnL and these are the  
registers that store the 16-bit count when a capture occurs or a  
compare should occur. When a module is used in the PWM mode  
these registers are used to control the duty cycle of the output.  
The CCON SFR contains the run control bit for the PCA and the  
flags for the PCA timer (CF) and each module (refer to Figure 18).  
To run the PCA the CR bit (CCON.6) must be set by software. The  
PCA is shut off by clearing this bit. The CF bit (CCON.7) is set when  
16 BITS  
P1.3/CEX0  
P1.4/CEX1  
P1.5/CEX2  
P1.6/CEX3  
MODULE 0  
MODULE 1  
MODULE 2  
MODULE 3  
MODULE 4  
16 BITS  
PCA TIMER/COUNTER  
TIME BASE FOR PCA MODULES  
MODULE FUNCTIONS:  
16-BIT CAPTURE  
16-BIT TIMER  
P1.7/CEX4  
SU00032  
16-BIT HIGH SPEED OUTPUT  
8-BIT PWM  
WATCHDOG TIMER (MODULE 4 ONLY)  
Figure 14. Programmable Counter Array (PCA)  
22  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
TO PCA  
MODULES  
OSC/6 (6 CLOCK MODE)  
OR  
OSC/12 (12 CLOCK MODE)  
OSC/2 (6 CLOCK MODE)  
OR  
OSC/4 (12 CLOCK MODE)  
OVERFLOW  
INTERRUPT  
CH  
CL  
16–BIT UP COUNTER  
TIMER 0 OVERFLOW  
EXTERNAL INPUT  
(P1.2/ECI)  
00  
01  
10  
11  
DECODE  
IDLE  
CMOD  
(C1H)  
CIDL  
CF  
WDTE  
––  
––  
––  
––  
CPS1  
CCF2  
CPS0  
ECF  
CCON  
(C0H)  
CR  
CCF4  
CCF3  
CCF1  
CCF0  
SU01256  
Figure 15. PCA Timer/Counter  
CCON  
(C0H)  
CF  
CR  
––  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
PCA TIMER/COUNTER  
MODULE 0  
IE.7  
EA  
IE.6  
EC  
TO  
MODULE 1  
MODULE 2  
INTERRUPT  
PRIORITY  
DECODER  
MODULE 3  
MODULE 4  
CCAPMn.0  
ECCFn  
CMOD.0  
ECF  
SU01097  
Figure 16. PCA Interrupt System  
23  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
CMOD Address = C1H  
Reset Value = 00XX X000B  
CIDL  
WDTE  
CPS1  
CPS0  
ECF  
Bit:  
Function  
7
6
5
4
3
2
1
0
Symbol  
CIDL  
Counter Idle control: CIDL = 0 programs the PCA Counter to continue functioning during idle Mode. CIDL = 1 programs  
it to be gated off during idle.  
WDTE  
Watchdog Timer Enable: WDTE = 0 disables Watchdog Timer function on PCA Module 4. WDTE = 1 enables it.  
Not implemented, reserved for future use.*  
CPS1  
CPS0  
PCA Count Pulse Select bit 1.  
PCA Count Pulse Select bit 0.  
CPS1  
CPS0  
Selected PCA Input**  
0
0
1
1
0
1
0
1
0
1
2
3
Internal clock, f  
/6 in 6 clock mode (f  
/2 in 6 clock mode (f  
/12 in 12 clock mode)  
/4 in 12 clock mode)  
OSC  
OSC  
OSC  
Internal clock, f  
OSC  
Timer 0 overflow  
External clock at ECI/P1.2 pin  
(max. rate = f /4 in 6 clock mode, f  
/8 in 12 clock mode)  
OCS  
OSC  
ECF  
PCA Enable Counter Overflow interrupt: ECF = 1 enables CF bit in CCON to generate an interrupt. ECF = 0 disables  
that function of CF.  
NOTE:  
*
User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the  
new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate.  
**  
f
= oscillator frequency  
OSC  
SU01257  
Figure 17. CMOD: PCA Counter Mode Register  
CCON Address = 0C0H  
Reset Value = 00X0 0000B  
Bit Addressable  
CF  
CR  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
Bit:  
7
6
5
4
3
2
1
0
Symbol  
CF  
Function  
PCA Counter Overflow flag. Set by hardware when the counter rolls over. CF flags an interrupt if bit ECF in CMOD is  
set. CF may be set by either hardware or software but can only be cleared by software.  
CR  
PCA Counter Run control bit. Set by software to turn the PCA counter on. Must be cleared by software to turn the PCA  
counter off.  
Not implemented, reserved for future use*.  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
PCA Module 4 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software.  
PCA Module 3 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software.  
PCA Module 2 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software.  
PCA Module 1 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software.  
PCA Module 0 interrupt flag. Set by hardware when a match or capture occurs. Must be cleared by software.  
NOTE:  
*
User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the  
new bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate.  
SU01099  
Figure 18. CCON: PCA Counter Control Register  
24  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
CCAPMn Address  
CCAPM0  
CCAPM1  
CCAPM2  
CCAPM3  
CCAPM4  
0C2H  
0C3H  
0C4H  
0C5H  
0C6H  
Reset Value = X000 0000B  
Not Bit Addressable  
ECOMn CAPPn  
CAPNn  
MATn  
TOGn  
PWMn  
ECCFn  
Bit:  
7
6
5
4
3
2
1
0
Symbol  
Function  
Not implemented, reserved for future use*.  
ECOMn  
CAPPn  
CAPNn  
MATn  
Enable Comparator. ECOMn = 1 enables the comparator function.  
Capture Positive, CAPPn = 1 enables positive edge capture.  
Capture Negative, CAPNn = 1 enables negative edge capture.  
Match. When MATn = 1, a match of the PCA counter with this module’s compare/capture register causes the CCFn bit  
in CCON to be set, flagging an interrupt.  
TOGn  
Toggle. When TOGn = 1, a match of the PCA counter with this module’s compare/capture register causes the CEXn  
pin to toggle.  
PWMn  
ECCFn  
Pulse Width Modulation Mode. PWMn = 1 enables the CEXn pin to be used as a pulse width modulated output.  
Enable CCF interrupt. Enables compare/capture flag CCFn in the CCON register to generate an interrupt.  
NOTE:  
*User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new  
bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate.  
SU01100  
Figure 19. CCAPMn: PCA Modules Compare/Capture Registers  
X
X
X
X
X
X
X
X
ECOMn CAPPn CAPNn  
MATn  
TOGn  
PWMn  
ECCFn  
MODULE FUNCTION  
0
X
X
X
1
1
1
1
0
1
0
1
0
0
0
0
0
0
1
1
0
0
0
0
0
0
0
0
1
1
0
1
0
0
0
0
0
1
0
X
0
0
0
0
0
0
1
0
0
X
X
X
X
X
0
No operation  
16-bit capture by a positive-edge trigger on CEXn  
16-bit capture by a negative trigger on CEXn  
16-bit capture by a transition on CEXn  
16-bit Software Timer  
16-bit High Speed Output  
8-bit PWM  
X
Watchdog Timer  
Figure 20. PCA Module Modes (CCAPMn Register)  
PCA Capture Mode  
counter and the module’s capture registers. To activate this mode  
the TOG, MAT, and ECOM bits in the module’s CCAPMn SFR must  
be set (see Figure 23).  
To use one of the PCA modules in the capture mode either one or  
both of the CCAPM bits CAPN and CAPP for that module must be  
set. The external CEX input for the module (on port 1) is sampled for  
a transition. When a valid transition occurs the PCA hardware loads  
the value of the PCA counter registers (CH and CL) into the  
module’s capture registers (CCAPnL and CCAPnH). If the CCFn bit  
for the module in the CCON SFR and the ECCFn bit in the CCAPMn  
SFR are set then an interrupt will be generated. Refer to Figure 21.  
Pulse Width Modulator Mode  
All of the PCA modules can be used as PWM outputs. Figure 24  
shows the PWM function. The frequency of the output depends on  
the source for the PCA timer. All of the modules will have the same  
frequency of output because they all share the PCA timer. The duty  
cycle of each module is independently variable using the module’s  
capture register CCAPLn. When the value of the PCA CL SFR is  
less than the value in the module’s CCAPLn SFR the output will be  
low, when it is equal to or greater than the output will be high. When  
CL overflows from FF to 00, CCAPLn is reloaded with the value in  
CCAPHn. the allows updating the PWM without glitches. The PWM  
and ECOM bits in the module’s CCAPMn register must be set to  
enable the PWM mode.  
16-bit Software Timer Mode  
The PCA modules can be used as software timers by setting both  
the ECOM and MAT bits in the modules CCAPMn register. The PCA  
timer will be compared to the module’s capture registers and when a  
match occurs an interrupt will occur if the CCFn (CCON SFR) and  
the ECCFn (CCAPMn SFR) bits for the module are both set (see  
Figure 22).  
High Speed Output Mode  
In this mode the CEX output (on port 1) associated with the PCA  
module will toggle each time a match occurs between the PCA  
25  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
CCON  
(0C0H)  
CF  
CR  
––  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
PCA INTERRUPT  
(TO CCFn)  
PCA TIMER/COUNTER  
CH  
CL  
CAPTURE  
CEXn  
CCAPnH  
CCAPnL  
CCAPMn, n= 0 to 4  
(C2H – C6H)  
––  
ECOMn  
0
CAPPn  
CAPNn  
MATn  
0
TOGn  
0
PWMn  
ECCFn  
0
SU01101  
Figure 21. PCA Capture Mode  
CCON  
(C0H)  
CF  
CR  
––  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
WRITE TO  
CCAPnH  
RESET  
PCA INTERRUPT  
CCAPnH  
CCAPnL  
WRITE TO  
CCAPnL  
(TO CCFn)  
0
1
ENABLE  
MATCH  
16–BIT COMPARATOR  
CH  
CL  
PCA TIMER/COUNTER  
CCAPMn, n= 0 to 4  
(C2H – C6H)  
––  
ECOMn  
CAPPn  
0
CAPNn  
0
MATn  
TOGn  
0
PWMn  
0
ECCFn  
SU01102  
Figure 22. PCA Compare Mode  
26  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
CCON  
(C0H)  
CF  
CR  
––  
CCF4  
CCF3  
CCF2  
CCF1  
CCF0  
WRITE TO  
CCAPnH  
RESET  
PCA INTERRUPT  
CCAPnH  
CCAPnL  
WRITE TO  
CCAPnL  
(TO CCFn)  
0
1
MATCH  
ENABLE  
16–BIT COMPARATOR  
TOGGLE  
CEXn  
CH  
CL  
PCA TIMER/COUNTER  
CCAPMn, n: 0..4  
(C2H – C6H)  
––  
ECOMn  
CAPPn  
0
CAPNn  
0
MATn  
TOGn  
PWMn  
0
ECCFn  
1
SU01103  
Figure 23. PCA High Speed Output Mode  
CCAPnH  
CCAPnL  
0
CL < CCAPnL  
ENABLE  
8–BIT  
CEXn  
COMPARATOR  
CL >= CCAPnL  
1
CL  
OVERFLOW  
PCA TIMER/COUNTER  
CCAPMn, n: 0..4  
(C2H – C6H)  
––  
ECOMn  
CAPPn  
0
CAPNn  
MATn  
0
TOGn  
0
PWMn  
ECCFn  
0
0
SU01104  
Figure 24. PCA PWM Mode  
27  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
CMOD  
(C1H)  
CIDL  
WDTE  
––  
––  
MODULE 4  
MATCH  
––  
CPS1  
CPS0  
ECF  
WRITE TO  
CCAP4L  
RESET  
CCAP4H  
CCAP4L  
WRITE TO  
CCAP4H  
1
0
ENABLE  
16–BIT COMPARATOR  
RESET  
CH  
CL  
PCA TIMER/COUNTER  
CCAPM4  
(C6H)  
––  
ECOMn  
CAPPn  
0
CAPNn  
0
MATn  
1
TOGn  
X
PWMn  
0
ECCFn  
X
SU01105  
Figure 25. PCA Watchdog Timer m(Module 4 only)  
PCA Watchdog Timer  
The first two options are more reliable because the watchdog  
timer is never disabled as in option #3. If the program counter ever  
goes astray, a match will eventually occur and cause an internal  
reset. The second option is also not recommended if other PCA  
modules are being used. Remember, the PCA timer is the time  
base for all modules; changing the time base for other modules  
would not be a good idea. Thus, in most applications the first  
solution is the best option.  
An on-board watchdog timer is available with the PCA to improve the  
reliability of the system without increasing chip count. Watchdog  
timers are useful for systems that are susceptible to noise, power  
glitches, or electrostatic discharge. Module 4 is the only PCA module  
that can be programmed as a watchdog. However, this module can  
still be used for other modes if the watchdog is not needed.  
Figure 25 shows a diagram of how the watchdog works. The user  
pre-loads a 16-bit value in the compare registers. Just like the other  
compare modes, this 16-bit value is compared to the PCA timer  
value. If a match is allowed to occur, an internal reset will be  
generated. This will not cause the RST pin to be driven high.  
Figure 26 shows the code for initializing the watchdog timer.  
Module 4 can be configured in either compare mode, and the WDTE  
bit in CMOD must also be set. The user’s software then must  
periodically change (CCAP4H,CCAP4L) to keep a match from  
occurring with the PCA timer (CH,CL). This code is given in the  
WATCHDOG routine in Figure 26.  
In order to hold off the reset, the user has three options:  
1. periodically change the compare value so it will never match the  
PCA timer,  
This routine should not be part of an interrupt service routine,  
because if the program counter goes astray and gets stuck in an  
infinite loop, interrupts will still be serviced and the watchdog will  
keep getting reset. Thus, the purpose of the watchdog would be  
2. periodically change the PCA timer value so it will never match  
the compare values, or  
3. disable the watchdog by clearing the WDTE bit before a match  
occurs and then re-enable it.  
defeated. Instead, call this subroutine from the main program within  
16  
2
count of the PCA timer.  
28  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
INIT_WATCHDOG:  
MOV CCAPM4, #4CH  
MOV CCAP4L, #0FFH  
MOV CCAP4H, #0FFH  
; Module 4 in compare mode  
; Write to low byte first  
; Before PCA timer counts up to  
; FFFF Hex, these compare values  
; must be changed  
ORL CMOD, #40H  
; Set the WDTE bit to enable the  
; watchdog timer without changing  
; the other bits in CMOD  
;
;********************************************************************  
;
; Main program goes here, but CALL WATCHDOG periodically.  
;
;********************************************************************  
;
WATCHDOG:  
CLR EA  
; Hold off interrupts  
MOV CCAP4L, #00  
MOV CCAP4H, CH  
SETB EA  
; Next compare value is within  
; 255 counts of the current PCA  
; timer value  
RET  
Figure 26. PCA Watchdog Timer Initialization Code  
29  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
For example:  
MOV @R0,#data  
Expanded Data RAM Addressing  
The 89C51RB2/RC2/RD2 has internal data memory that is mapped  
into four separate segments: the lower 128 bytes of RAM, upper 128  
bytes of RAM, 128 bytes Special Function Register (SFR), and  
256 bytes expanded RAM (ERAM) (768 bytes for the RD2).  
where R0 contains 0A0H, accesses the data byte at address 0A0H,  
rather than P2 (whose address is 0A0H).  
The ERAM can be accessed by indirect addressing, with EXTRAM  
bit cleared and MOVX instructions. This part of memory is physically  
located on-chip, logically occupies the first 7936-bytes of external  
data memory.  
The four segments are:  
1. The Lower 128 bytes of RAM (addresses 00H to 7FH) are  
directly and indirectly addressable.  
2. The Upper 128 bytes of RAM (addresses 80H to FFH) are  
indirectly addressable only.  
With EXTRAM = 0, the ERAM is indirectly addressed, using the  
MOVX instruction in combination with any of the registers R0, R1 of  
the selected bank or DPTR. An access to ERAM will not affect ports  
P0, P3.6 (WR#) and P3.7 (RD#). P2 SFR is output during external  
addressing. For example, with EXTRAM = 0,  
3. The Special Function Registers, SFRs, (addresses 80H to FFH)  
are directly addressable only.  
4. The 256/768-bytes expanded RAM (ERAM, 00H – 1FFH/2FFH)  
are indirectly accessed by move external instruction, MOVX, and  
with the EXTRAM bit cleared, see Figure 27.  
MOVX @R0,#data  
where R0 contains 0A0H, access the ERAM at address 0A0H rather  
than external memory. An access to external data memory locations  
higher than the ERAM will be performed with the MOVX DPTR  
instructions in the same way as in the standard 80C51, so with P0  
and P2 as data/address bus, and P3.6 and P3.7 as write and read  
timing signals. Refer to Figure 28.  
The Lower 128 bytes can be accessed by either direct or indirect  
addressing. The Upper 128 bytes can be accessed by indirect  
addressing only. The Upper 128 bytes occupy the same address  
space as the SFR. That means they have the same address, but are  
physically separate from SFR space.  
With EXTRAM = 1, MOVX @Ri and MOVX @DPTR will be similar  
to the standard 80C51. MOVX @ Ri will provide an 8-bit address  
multiplexed with data on Port 0 and any output port pins can be  
used to output higher order address bits. This is to provide the  
external paging capability. MOVX @DPTR will generate a 16-bit  
address. Port 2 outputs the high-order eight address bits (the  
contents of DPH) while Port 0 multiplexes the low-order eight  
address bits (DPL) with data. MOVX @Ri and MOVX @DPTR will  
generate either read or write signals on P3.6 (WR) and P3.7 (RD).  
When an instruction accesses an internal location above address  
7FH, the CPU knows whether the access is to the upper 128 bytes  
of data RAM or to SFR space by the addressing mode used in the  
instruction. Instructions that use direct addressing access SFR  
space. For example:  
MOV 0A0H,#data  
accesses the SFR at location 0A0H (which is P2). Instructions that  
use indirect addressing access the Upper 128 bytes of data RAM.  
The stack pointer (SP) may be located anywhere in the 256 bytes  
RAM (lower and upper RAM) internal data memory. The stack may  
not be located in the ERAM.  
AUXR  
Address = 8EH  
Reset Value = xxxx xx00B  
Not Bit Addressable  
6
5
4
3
2
EXTRAM  
AO  
Bit:  
Function  
Disable/Enable ALE  
7
1
0
Symbol  
AO  
AO  
0
Operating Mode  
1
1
ALE is emitted at a constant rate of / the oscillator frequency (6 clock mode; / f  
in 12 clock mode).  
3
6
OSC  
1
ALE is active only during a MOVX or MOVC instruction.  
EXTRAM  
Internal/External RAM access using MOVX @Ri/@DPTR  
EXTRAM  
Operating Mode  
0
1
Internal ERAM access using MOVX @Ri/@DPTR  
External data memory access.  
Not implemented, reserved for future use*.  
NOTE:  
*User software should not write 1s to reserved bits. These bits may be used in future 8051 family products to invoke new features. In that case, the reset or inactive value of the new  
bit will be 0, and its active value will be 1. The value read from a reserved bit is indeterminate.  
SU01258  
Figure 27. AUXR: Auxiliary Register  
30  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
FF  
FF  
FFFF  
UPPER  
128 BYTES  
INTERNAL RAM  
SPECIAL  
FUNCTION  
REGISTER  
EXTERNAL  
DATA  
MEMORY  
80  
80  
ERAM  
256 or 768 BYTES  
LOWER  
128 BYTES  
INTERNAL RAM  
100  
00  
00  
0000  
SU01293  
Figure 28. Internal and External Data Memory Address Space with EXTRAM = 0  
HARDWARE WATCHDOG TIMER (ONE-TIME ENABLED WITH RESET-OUT FOR 89C51RB2/RC2/RD2)  
The WDT is intended as a recovery method in situations where the CPU may be subjected to software upset. The WDT consists of a 14-bit  
counter and the WatchDog Timer reset (WDTRST) SFR. The WDT is disabled at reset. To enable the WDT, user must write 01EH and 0E1H in  
sequence to the WDTRST, SFR location 0A6H. When WDT is enabled, it will increment every machine cycle while the oscillator is running and  
there is no way to disable the WDT except through reset (either hardware reset or WDT overflow reset). When WDT overflows, it will drive an  
output reset HIGH pulse at the RST-pin (see the note below).  
Using the WDT  
To enable the WDT, user must write 01EH and 0E1H in sequence to the WDTRST, SFR location 0A6H. When WDT is enabled, the user needs to  
service it by writing to 01EH and 0E1H to WDTRST to avoid WDT overflow. The 14-bit counter overflows when it reaches 16383 (3FFFH) and this  
will reset the device. When WDT is enabled, it will increment every machine cycle while the oscillator is running. This means the user must reset  
the WDT at least every 16383 machine cycles. To reset the WDT, the user must write 01EH and 0E1H to WDTRST. WDTRST is a write only  
register. The WDT counter cannot be read or written. When WDT overflows, it will generate an output RESET pulse at the reset pin (see note  
below). The RESET pulse duration is 98 × T  
(6 clock mode; 196 in 12 clock mode), where T  
= 1/f . To make the best use of the WDT, it  
OSC  
OSC  
OSC  
should be serviced in those sections of code that will periodically be executed within the time required to prevent a WDT reset.  
1, 2, 3  
ABSOLUTE MAXIMUM RATINGS  
PARAMETER  
RATING  
0 to +70 or –40 to +85  
–65 to +150  
0 to +13.0  
–0.5 to +6.5  
15  
UNIT  
°C  
°C  
V
Operating temperature under bias  
Storage temperature range  
Voltage on EA/V pin to V  
PP  
SS  
Voltage on any other pin to V  
V
SS  
Maximum I per I/O pin  
mA  
W
OL  
Power dissipation (based on package heat transfer limitations, not device power consumption)  
1.5  
NOTES:  
1. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only and  
functional operation of the device at these or any conditions other than those described in the AC and DC Electrical Characteristics section  
of this specification is not implied.  
2. This product includes circuitry specifically designed for the protection of its internal devices from the damaging effects of excessive static  
charge. Nonetheless, it is suggested that conventional precautions be taken to avoid applying greater than the rated maximum.  
3. Parameters are valid over operating temperature range unless otherwise specified. All voltages are with respect to V unless otherwise noted.  
SS  
4. Programming is guaranteed from 0°C to T  
for all devices.  
max  
31  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
DC ELECTRICAL CHARACTERISTICS  
T
amb  
= 0°C to +70°C or –40°C to +85°C; 5 V ±10%; V = 0 V  
SS  
LIMITS  
TEST  
CONDITIONS  
SYMBOL  
PARAMETER  
UNIT  
1
MIN  
TYP  
MAX  
0.2V –0.1  
V
V
V
Input low voltage  
4.5 V < V < 5.5 V  
–0.5  
V
V
V
IL  
CC  
CC  
Input high voltage (ports 0, 1, 2, 3, EA)  
Input high voltage, XTAL1, RST  
0.2V +0.9  
V
CC  
V
CC  
+0.5  
+0.5  
IH  
CC  
0.7V  
IH1  
CC  
V
OL  
= 4.5 V  
= 1.6 mA  
CC  
8
V
V
V
V
Output low voltage, ports 1, 2, 3  
0.4  
V
V
V
OL  
2
I
I
V
CC  
= 4.5 V  
7, 8  
Output low voltage, port 0, ALE, PSEN  
0.4  
OL1  
OH  
2
= 3.2 mA  
OL  
V
CC  
= 4.5 V  
= –30 µA  
3
Output high voltage, ports 1, 2, 3  
V
V
– 0.7  
– 0.7  
CC  
I
OH  
Output high voltage (port 0 in external bus mode),  
V
CC  
= 4.5 V  
= –3.2 mA  
V
OH1  
CC  
9
3
ALE , PSEN  
I
OH  
I
I
Logical 0 input current, ports 1, 2, 3  
Logical 1-to-0 transition current, ports 1, 2, 3  
Input leakage current, port 0  
V
V
= 0.4 V  
= 2.0 V  
–1  
–75  
–650  
±10  
µA  
µA  
µA  
IL  
IN  
IN  
6
TL  
See Note 4  
I
I
0.45 < V < V – 0.3  
LI  
IN  
CC  
Power supply current (see Figure 36):  
Active mode (see Note 5)  
See Note 5  
CC  
Idle mode (see Note 5)  
Power-down mode or clock stopped (see  
Figure 42 for conditions)  
T
= 0°C to 70°C  
= –40°C to +85°C  
< 1  
40  
50  
µA  
µA  
amb  
T
amb  
R
C
Internal reset pull-down resistor  
40  
225  
15  
kΩ  
RST  
IO  
10  
Pin capacitance (except EA)  
pF  
NOTES:  
1. Typical ratings are not guaranteed. The values listed are at room temperature, 5 V.  
2. Capacitive loading on ports 0 and 2 may cause spurious noise to be superimposed on the V s of ALE and ports 1 and 3. The noise is due  
OL  
to external bus capacitance discharging into the port 0 and port 2 pins when these pins make 1-to-0 transitions during bus operations. In the  
worst cases (capacitive loading > 100 pF), the noise pulse on the ALE pin may exceed 0.8 V. In such cases, it may be desirable to qualify  
ALE with a Schmitt Trigger, or use an address latch with a Schmitt Trigger STROBE input. I can exceed these conditions provided that no  
OL  
single output sinks more than 5 mA and no more than two outputs exceed the test conditions.  
3. Capacitive loading on ports 0 and 2 may cause the V on ALE and PSEN to momentarily fall below the V –0.7 specification when the  
OH  
CC  
address bits are stabilizing.  
4. Pins of ports 1, 2 and 3 source a transition current when they are being externally driven from 1 to 0. The transition current reaches its  
maximum value when V is approximately 2 V.  
IN  
5. See Figures 39 through 42 for I test conditions and Figure 36 for I vs Freq.  
CC  
CC  
Active mode:  
Idle mode:  
6. This value applies to T  
I
I
= (1.8 × FREQ. + 20)mA for all devices, in 6 clock mode; (0.9 × FREQ. + 20)mA in 12 clock mode.  
= (0.7 × FREQ. +1.0)mA in 6 clock mode; (0.35 × FREQ. +1.0)mA in 12 clock mode.  
= 0°C to +70°C.  
CC(MAX)  
CC(MAX)  
amb  
7. Load capacitance for port 0, ALE, and PSEN = 100 pF, load capacitance for all other outputs = 80 pF.  
8. Under steady state (non-transient) conditions, I must be externally limited as follows:  
OL  
Maximum I per port pin:  
15 mA (*NOTE: This is 85°C specification.)  
OL  
Maximum I per 8-bit port:  
26 mA  
71 mA  
OL  
Maximum total I for all outputs:  
OL  
If I exceeds the test condition, V may exceed the related specification. Pins are not guaranteed to sink current greater than the listed  
OL  
OL  
test conditions.  
9. ALE is tested to V  
, except when ALE is off then V is the voltage specification.  
OH  
OH1  
10.Pin capacitance is characterized but not tested. Pin capacitance is less than 25 pF. Pin capacitance of ceramic package is less than 15 pF  
(except EA is 25 pF).  
11. Programming is guaranteed from 0°C to T  
for all devices.  
max  
32  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
AC ELECTRICAL CHARACTERISTICS (6 CLOCK MODE)  
1, 2, 3  
T
amb  
= 0°C to +70°C or –40°C to +85°C, V = 5 V ±10%, V = 0V  
CC SS  
4
4
VARIABLE CLOCK  
20 MHz CLOCK  
SYMBOL FIGURE  
PARAMETER  
MIN  
MAX  
MIN  
0
MAX  
UNIT  
MHz  
ns  
1/t  
CLCL  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
Oscillator frequency  
ALE pulse width  
0
20  
20  
t
t
t
t
t
t
t
t
t
t
t
t
–40  
10  
5
LHLL  
CLCL  
Address valid to ALE low  
Address hold after ALE low  
ALE low to valid instruction in  
ALE low to PSEN low  
0.5t  
0.5t  
–20  
–20  
ns  
AVLL  
LLAX  
LLIV  
CLCL  
5
ns  
CLCL  
2t  
–65  
35  
15  
ns  
CLCL  
0.5t  
1.5t  
–20  
–45  
5
ns  
LLPL  
PLPH  
PLIV  
PXIX  
PXIZ  
AVIV  
PLAZ  
CLCL  
PSEN pulse width  
30  
ns  
CLCL  
PSEN low to valid instruction in  
Input instruction hold after PSEN  
Input instruction float after PSEN  
Address to valid instruction in  
PSEN low to address float  
1.5t  
–60  
ns  
CLCL  
0
0
ns  
0.5t  
2.5t  
–20  
–80  
5
ns  
CLCL  
45  
10  
ns  
CLCL  
10  
ns  
Data Memory  
t
t
t
t
t
t
t
t
t
t
t
t
t
t
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
31  
RD pulse width  
3t  
3t  
–100  
–100  
50  
50  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
RLRH  
WLWH  
RLDV  
RHDX  
RHDZ  
LLDV  
CLCL  
WR pulse width  
CLCL  
RD low to valid data in  
Data hold after RD  
Data float after RD  
ALE low to valid data in  
Address to valid data in  
ALE low to RD or WR low  
2.5t  
–90  
35  
CLCL  
0
0
t
–20  
5
CLCL  
4t  
CLCL  
–150  
–165  
50  
4.5t  
60  
AVDV  
LLWL  
CLCL  
1.5t  
–50 1.5t  
+50  
25  
25  
0
125  
CLCL  
CLCL  
Address valid to WR low or RD low  
Data valid to WR transition  
Data hold after WR  
2t  
–75  
AVWL  
QVWX  
WHQX  
QVWH  
RLAZ  
WHLH  
CLCL  
0.5t  
0.5t  
–25  
–20  
CLCL  
5
CLCL  
Data valid to WR high  
3.5t  
–130  
CLCL  
45  
30, 31  
30, 31  
RD low to address float  
RD or WR high to ALE high  
0
0
0.5t  
–20 0.5t  
+20  
5
45  
CLCL  
CLCL  
External Clock  
t
t
t
t
33  
33  
33  
33  
High time  
Low time  
Rise time  
Fall time  
20  
20  
t
–t  
ns  
ns  
ns  
ns  
CHCX  
CLCX  
CLCH  
CHCL  
CLCL CLCX  
t
–t  
CLCL CHCX  
5
5
Shift Register  
t
t
t
t
t
32  
32  
32  
32  
32  
Serial port clock cycle time  
6t  
300  
117  
20  
ns  
ns  
ns  
ns  
ns  
XLXL  
CLCL  
Output data setup to clock rising edge  
Output data hold after clock rising edge  
Input data hold after clock rising edge  
Clock rising edge to input data valid  
5t  
–133  
CLCL  
QVXH  
XHQX  
XHDX  
XHDV  
t
–30  
CLCL  
0
0
5t  
CLCL  
–133  
117  
NOTES:  
1. Parameters are valid over operating temperature range unless otherwise specified.  
2. Load capacitance for port 0, ALE, and PSEN = 100 pF, load capacitance for all other outputs = 80 pF.  
3. Interfacing the microcontroller to devices with float times up to 45 ns is permitted. This limited bus contention will not cause damage to  
Port 0 drivers.  
4. Parts are tested to 2 MHz, but are guaranteed to operate down to 0 Hz.  
33  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
AC ELECTRICAL CHARACTERISTICS (12 CLOCK MODE)  
1, 2, 3  
T
amb  
= 0°C to +70°C or –40°C to +85°C, V = 5 V ±10%, V = 0 V  
CC SS  
4
4
VARIABLE CLOCK  
33 MHz CLOCK  
SYMBOL FIGURE  
PARAMETER  
MIN  
MAX  
MIN  
0
MAX  
UNIT  
MHz  
ns  
1/t  
CLCL  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
29  
Oscillator frequency  
ALE pulse width  
0
33  
33  
t
t
t
t
t
t
t
t
t
t
t
2t  
–40  
21  
5
LHLL  
CLCL  
Address valid to ALE low  
Address hold after ALE low  
ALE low to valid instruction in  
ALE low to PSEN low  
t
t
–25  
ns  
AVLL  
LLAX  
LLIV  
CLCL  
CLCL  
–25  
5
ns  
4t  
3t  
–65  
–60  
55  
30  
ns  
CLCL  
t
–25  
5
ns  
LLPL  
PLPH  
PLIV  
PXIX  
PXIZ  
AVIV  
PLAZ  
CLCL  
PSEN pulse width  
3t  
–45  
45  
ns  
CLCL  
PSEN low to valid instruction in  
Input instruction hold after PSEN  
Input instruction float after PSEN  
Address to valid instruction in  
PSEN low to address float  
ns  
CLCL  
0
0
ns  
t
–25  
5
ns  
CLCL  
5t  
–80  
70  
10  
ns  
CLCL  
10  
ns  
Data Memory  
t
t
t
t
t
t
t
t
t
t
t
t
t
t
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
30, 31  
31  
RD pulse width  
6t  
–100  
–100  
82  
82  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
ns  
RLRH  
WLWH  
RLDV  
RHDX  
RHDZ  
LLDV  
CLCL  
WR pulse width  
6t  
CLCL  
RD low to valid data in  
Data hold after RD  
Data float after RD  
ALE low to valid data in  
Address to valid data in  
ALE low to RD or WR low  
5t  
2t  
–90  
–28  
60  
CLCL  
0
0
32  
90  
CLCL  
8t  
–150  
–165  
CLCL  
CLCL  
9t  
105  
140  
AVDV  
LLWL  
3t  
–50  
–75  
3t  
CLCL  
+50  
40  
45  
0
CLCL  
Address valid to WR low or RD low  
Data valid to WR transition  
Data hold after WR  
4t  
AVWL  
QVWX  
WHQX  
QVWH  
RLAZ  
WHLH  
CLCL  
t
t
–30  
–25  
CLCL  
CLCL  
5
Data valid to WR high  
7t  
–130  
80  
CLCL  
30, 31  
30, 31  
RD low to address float  
RD or WR high to ALE high  
0
0
t
–25  
t
+25  
5
55  
CLCL  
CLCL  
External Clock  
t
t
t
t
33  
33  
33  
33  
High time  
Low time  
Rise time  
Fall time  
17  
17  
t
–t  
ns  
ns  
ns  
ns  
CHCX  
CLCX  
CLCH  
CHCL  
CLCL CLCX  
t
–t  
CLCL CHCX  
5
5
Shift Register  
t
t
t
t
t
32  
32  
32  
32  
32  
Serial port clock cycle time  
12t  
360  
167  
50  
ns  
ns  
ns  
ns  
ns  
XLXL  
CLCL  
Output data setup to clock rising edge  
Output data hold after clock rising edge  
Input data hold after clock rising edge  
Clock rising edge to input data valid  
10t –133  
CLCL  
QVXH  
XHQX  
XHDX  
XHDV  
2t  
CLCL  
–80  
0
0
10t  
–133  
167  
CLCL  
NOTES:  
1. Parameters are valid over operating temperature range unless otherwise specified.  
2. Load capacitance for port 0, ALE, and PSEN = 100 pF, load capacitance for all other outputs = 80 pF.  
3. Interfacing the microcontroller to devices with float times up to 45 ns is permitted. This limited bus contention will not cause damage to  
Port 0 drivers.  
4. Parts are tested to 3.5 MHz, but guaranteed to operate down to 0 Hz.  
34  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
EXPLANATION OF THE AC SYMBOLS  
Each timing symbol has five characters. The first character is always  
P – PSEN  
‘t’ (= time). The other characters, depending on their positions,  
indicate the name of a signal or the logical status of that signal. The  
designations are:  
Q – Output data  
R – RD signal  
t – Time  
A – Address  
V – Valid  
C – Clock  
W– WR signal  
D – Input data  
X – No longer a valid logic level  
Z – Float  
H – Logic level high  
I – Instruction (program memory contents)  
L – Logic level low, or ALE  
Examples: t  
= Time for address valid to ALE low.  
= Time for ALE low to PSEN low.  
AVLL  
LLPL  
t
t
LHLL  
ALE  
t
t
LLPL  
AVLL  
t
PLPH  
t
LLIV  
t
PLIV  
PSEN  
t
LLAX  
t
PXIZ  
t
PLAZ  
t
PXIX  
A0–A7  
INSTR IN  
A0–A7  
PORT 0  
PORT 2  
t
AVIV  
A0–A15  
A8–A15  
SU00006  
Figure 29. External Program Memory Read Cycle  
ALE  
PSEN  
RD  
t
WHLH  
t
LLDV  
t
t
LLWL  
RLRH  
t
RHDZ  
t
LLAX  
t
t
RLDV  
AVLL  
t
RLAZ  
t
RHDX  
A0–A7  
FROM RI OR DPL  
PORT 0  
PORT 2  
DATA IN  
A0–A7 FROM PCL  
INSTR IN  
t
AVWL  
t
AVDV  
P2.0–P2.7 OR A8–A15 FROM DPF  
A0–A15 FROM PCH  
SU00025  
Figure 30. External Data Memory Read Cycle  
35  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
ALE  
t
WHLH  
PSEN  
t
t
WLWH  
LLWL  
WR  
t
LLAX  
t
t
WHQX  
t
AVLL  
QVWX  
t
QVWH  
A0–A7  
FROM RI OR DPL  
PORT 0  
PORT 2  
DATA OUT  
A0–A7 FROM PCL  
INSTR IN  
t
AVWL  
P2.0–P2.7 OR A8–A15 FROM DPF  
A0–A15 FROM PCH  
SU00026  
Figure 31. External Data Memory Write Cycle  
INSTRUCTION  
ALE  
0
1
2
3
4
5
6
7
8
t
XLXL  
CLOCK  
t
XHQX  
t
QVXH  
OUTPUT DATA  
0
1
2
3
4
5
6
7
WRITE TO SBUF  
t
XHDX  
t
SET TI  
VALID  
XHDV  
INPUT DATA  
CLEAR RI  
VALID  
VALID  
VALID  
VALID  
VALID  
VALID  
VALID  
SET RI  
SU00027  
Figure 32. Shift Register Mode Timing  
V
–0.5  
CC  
0.7V  
CC  
CC  
0.45V  
0.2V  
–0.1  
t
CHCX  
t
t
t
CHCL  
CLCX  
CLCH  
t
CLCL  
SU00009  
Figure 33. External Clock Drive  
36  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
V
–0.5  
CC  
V
V
+0.1V  
LOAD  
V
V
–0.1V  
TIMING  
REFERENCE  
POINTS  
OH  
0.2V  
0.2V  
+0.9  
–0.1  
CC  
V
LOAD  
CC  
–0.1V  
LOAD  
+0.1V  
OL  
0.45V  
NOTE:  
NOTE:  
For timing purposes, a port is no longer floating when a 100mV change from  
load voltage occurs, and begins to float when a 100mV change from the loaded  
AC inputs during testing are driven at V –0.5 for a logic ‘1’ and 0.45V for a logic ‘0’.  
Timing measurements are made at V min for a logic ‘1’ and V max for a logic ‘0’.  
CC  
IH  
IL  
V
/V level occurs. I /I ≥ ±20mA.  
OH OL  
OH OL  
SU00717  
SU00718  
Figure 34. AC Testing Input/Output  
Figure 35. Float Waveform  
60  
50  
I
(mA)  
CC  
40  
89C51RB2/RC2/RD2  
MAXIMUM ACTIVE I  
CC  
30  
20  
TYPICAL ACTIVE I  
CC  
10  
MAXIMUM IDLE  
TYPICAL IDLE  
2
4
6
8
10  
12  
14  
16  
18  
Frequency at XTAL1 (MHz, 6 clock mode)  
SU01300  
Figure 36. I vs. FREQ  
CC  
Valid only within frequency specifications of the device under test  
V
–0.5  
CC  
0.2V  
0.2V  
+0.9  
–0.1  
CC  
CC  
0.45V  
NOTE:  
AC inputs during testing are driven at V –0.5 for a logic ‘1’ and 0.45V for a logic ‘0’.  
CC  
Timing measurements are made at V min for a logic ‘1’ and V max for a logic ‘0’.  
IH  
IL  
SU00010  
Figure 37. AC Testing Input/Output  
37  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
V
V
+0.1V  
LOAD  
V
V
–0.1V  
TIMING  
REFERENCE  
POINTS  
OH  
V
LOAD  
–0.1V  
LOAD  
+0.1V  
OL  
NOTE:  
For timing purposes, a port is no longer floating when a 100mV change from load voltage occurs,  
and begins to float when a 100mV change from the loaded V /V level occurs. I /I ≥ ±20mA.  
OH OL  
OH OL  
SU00011  
Figure 38. Float Waveform  
V
V
–0.5  
CC  
CC  
CC  
0.5V  
I
CC  
t
CHCX  
t
t
t
CHCL  
CLCX  
CLCH  
V
CC  
P0  
V
V
CC  
t
CLCL  
89C51RB2  
89C51RC2  
89C51RD2  
RST  
SU01297  
EA  
Figure 41. Clock Signal Waveform for I Tests in Active  
(NC)  
XTAL2  
XTAL1  
CC  
and Idle Modes.  
CLOCK SIGNAL  
t
= t  
= 10 ns  
CHCL  
CLCL  
V
SS  
V
CC  
CC  
SU01294  
I
CC  
Figure 39. I Test Condition, Active Mode.  
CC  
V
CC  
All other pins are disconnected  
RST  
EA  
V
P0  
89C51RB2  
89C51RC2  
89C51RD2  
V
CC  
I
CC  
(NC)  
XTAL2  
XTAL1  
V
CC  
P0  
RST  
EA  
V
CC  
V
SS  
89C51RB2  
89C51RC2  
89C51RD2  
SU01296  
(NC)  
XTAL2  
XTAL1  
Figure 42. I Test Condition, Power Down Mode.  
CC  
CLOCK SIGNAL  
All other pins are disconnected; V = 2V to 5.5V  
CC  
V
SS  
SU01295  
Figure 40. I Test Condition, Idle Mode.  
CC  
All other pins are disconnected  
38  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
FLASH EPROM MEMORY  
CAPABILITIES OF THE PHILIPS 89C51  
FLASH-BASED MICROCONTROLLERS  
GENERAL DESCRIPTION  
Flash organization  
The 89C51RB2/RC2/RD2 Flash memory augments EPROM  
functionality with in-circuit electrical erasure and programming. The  
Flash can be read and written as bytes. The Chip Erase operation will  
erase the entire program memory. The Block Erase function can  
erase any Flash block. In-system programming and standard parallel  
programming are both available. On-chip erase and write timing  
generation contribute to a user friendly programming interface.  
The 89C51RB2/RC2/RD2 contains 16KB/32KB/64Kbytes of Flash  
program memory. This memory is organized as 5 separate blocks.  
The first two blocks are 8 kB in size, filling the program memory  
space from address 0 through 3FFF hex. The final three blocks are  
16 kB in size and occupy addresses from 4000 through FFFF hex.  
Figure 43 depicts the Flash memory configurations.  
The 89C51RB2/RC2/RD2 Flash reliably stores memory contents  
even after 1000 erase and program cycles. The cell is designed to  
optimize the erase and programming mechanisms. In addition, the  
combination of advanced tunnel oxide processing and low internal  
electric fields for erase and programming operations produces  
Flash Programming and Erasure  
There are three methods of erasing or programming of the Flash  
memory that may be used. First, the Flash may be programmed or  
erased in the end-user application by calling low-level routines  
through a common entry point in the Boot ROM. The end-user  
application, though, must be executing code from a different block  
than the block that is being erased or programmed. Second, the  
on-chip ISP boot loader may be invoked. This ISP boot loader will, in  
turn, call low-level routines through the same common entry point in  
the Boot ROM that can be used by the end-user application. Third,  
the Flash may be programmed or erased using the parallel method  
by using a commercially available EPROM programmer. The parallel  
programming method used by these devices is similar to that used  
by EPROM 87C51, but it is not identical, and the commercially  
available programmer will need to have support for these devices.  
reliable cycling. The 89C51RB2/RC2/RD2 uses a +5 V V supply  
PP  
to perform the Program/Erase algorithms.  
FEATURES  
Flash EPROM internal program memory with Block Erase.  
Internal 1 kB fixed boot ROM, containing low-level in-system  
programming routines and a default serial loader. User program  
can call these routines to perform In-Application Programming  
(IAP). The Boot ROM can be turned off to provide access to the  
full 64 kB Flash memory.  
Boot ROM  
When the microcontroller programs its own Flash memory, all of the  
low level details are handled by code that is permanently contained  
in a 1 kB Boot ROM that is separate from the Flash memory. A user  
program simply calls the common entry point with appropriate  
parameters in the Boot ROM to accomplish the desired operation.  
Boot ROM operations include things like: erase block, program byte,  
verify byte, program security lock bit, etc. The Boot ROM overlays  
the program memory space at the top of the address space from  
FC00 to FFFF hex, when it is enabled. The Boot ROM may be  
turned off so that the upper 1 kB of Flash program memory are  
accessible for execution.  
Boot vector allows user provided Flash loader code to reside  
anywhere in the Flash memory space. This configuration provides  
flexibility to the user.  
Default loader in Boot ROM allows programming via the serial port  
without the need for a user provided loader.  
Up to 64 kB external program memory if the internal program  
memory is disabled (EA = 0).  
Programming and erase voltage +5 V or +12 V.  
Read/Programming/Erase:  
Byte-wise read (100 ns access time).  
Byte Programming (20 ms).  
Typical erase times:  
Block Erase (8 kB or 16 kB) in 3 seconds.  
Full Erase (64 kB) in 3 seconds.  
Parallel programming with 87C51 compatible hardware interface  
to programmer.  
In-system programming.  
Programmable security for the code in the Flash.  
1000 minimum erase/program cycles for each byte.  
10-year minimum data retention.  
39  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
FFFF  
FFFF  
BOOT ROM  
(1 kB)  
FC00  
BLOCK 4  
16 kB  
89C51RD2  
C000  
BLOCK 3  
16 kB  
PROGRAM  
ADDRESS  
8000  
BLOCK 2  
16 kB  
89C51RC2  
4000  
BLOCK 1  
8 kB  
2000  
89C51RB2  
BLOCK 0  
8 kB  
0000  
SU01298  
Figure 43. Flash Memory Configurations  
Power-On Reset Code Execution  
Hardware Activation of the Boot Loader  
The 89C51RB2/RC2/RD2 contains two special Flash registers: the  
BOOT VECTOR and the STATUS BYTE. At the falling edge of reset,  
the 89C51RB2/RC2/RD2 examines the contents of the Status Byte.  
If the Status Byte is set to zero, power-up execution starts at  
location 0000H, which is the normal start address of the user’s  
application code. When the Status Byte is set to a value other than  
zero, the contents of the Boot Vector is used as the high byte of the  
execution address and the low byte is set to 00H. The factory  
default setting is 0FCH, corresponds to the address 0FC00H for the  
factory masked-ROM ISP boot loader. A custom boot loader can be  
written with the Boot Vector set to the custom boot loader.  
The boot loader can also be executed by holding PSEN LOW,  
EA greater than V (such as +5 V), and ALE HIGH (or not connected)  
IH  
at the falling edge of RESET. This is the same effect as having a  
non-zero status byte. This allows an application to be built that will  
normally execute the end user’s code but can be manually forced  
into ISP operation.  
If the factory default setting for the Boot Vector (0FCH) is changed, it  
will no longer point to the ISP masked-ROM boot loader code. If this  
happens, the only way it is possible to change the contents of the  
Boot Vector is through the parallel programming method, provided  
that the end user application does not contain a customized loader  
that provides for erasing and reprogramming of the Boot Vector and  
Status Byte.  
NOTE: When erasing the Status Byte or Boot Vector,  
both bytes are erased at the same time. It is necessary  
to reprogram the Boot Vector after erasing and  
updating the Status Byte.  
After programming the Flash, the status byte should be programmed  
to zero in order to allow execution of the user’s application code  
beginning at address 0000H.  
40  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
V
CC  
V
+12 V OR + 5 V  
PP  
RST  
V
+5 V  
TxD  
RxD  
CC  
TxD  
RxD  
XTAL2  
V
89C51RB2  
89C51RC2  
89C51RD2  
SS  
XTAL1  
V
SS  
SU01299  
Figure 44. In-System Programming with a Minimum of Pins  
first byte in the record. If there are zero bytes in the record, this field  
In-System Programming (ISP)  
is often set to 0000. The “RR” string indicates the record type. A  
record type of “00” is a data record. A record type of “01” indicates  
the end-of-file mark. In this application, additional record types will  
be added to indicate either commands or data for the ISP facility.  
The maximum number of data bytes in a record is limited to 16  
(decimal). ISP commands are summarized in Table 8.  
The In-System Programming (ISP) is performed without removing  
the microcontroller from the system. The In-System Programming  
(ISP) facility consists of a series of internal hardware resources  
coupled with internal firmware to facilitate remote programming of  
the 89C51RB2/RC2/RD2 through the serial port. This firmware is  
provided by Philips and embedded within each  
89C51RB2/RC2/RD2 device.  
As a record is received by the 89C51RB2/RC2/RD2, the information  
in the record is stored internally and a checksum calculation is  
performed. The operation indicated by the record type is not  
performed until the entire record has been received. Should an error  
occur in the checksum, the 89C51RB2/RC2/RD2 will send an “X”  
out the serial port indicating a checksum error. If the checksum  
calculation is found to match the checksum in the record, then the  
command will be executed. In most cases, successful reception of  
the record will be indicated by transmitting a “.” character out the  
serial port (displaying the contents of the internal program memory  
is an exception).  
The Philips In-System Programming (ISP) facility has made in-circuit  
programming in an embedded application possible with a minimum  
of additional expense in components and circuit board area.  
The ISP function uses five pins: TxD, RxD, V , V , and V (see  
Figure 44). Only a small connector needs to be available to interface  
your application to an external circuit in order to use this feature.  
SS  
CC  
PP  
The V supply should be adequately decoupled and V not  
PP  
PP  
allowed to exceed datasheet limits.  
Using the In-System Programming (ISP)  
In the case of a Data Record (record type 00), an additional check is  
made. A “.” character will NOT be sent unless the record checksum  
matched the calculated checksum and all of the bytes in the record  
were successfully programmed. For a data record, an “X” indicates  
that the checksum failed to match, and an “R” character indicates  
that one of the bytes did not properly program. It is necessary to  
send a type 02 record (specify oscillator frequency) to the  
89C51RB2/RC2/RD2 before programming data.  
The ISP feature allows for a wide range of baud rates to be used in  
your application, independent of the oscillator frequency. It is also  
adaptable to a wide range of oscillator frequencies. This is  
accomplished by measuring the bit-time of a single bit in a received  
character. This information is then used to program the baud rate in  
terms of timer counts based on the oscillator frequency. The ISP  
feature requires that an initial character (an uppercase U) be sent to  
the 89C51RB2/RC2/RD2 to establish the baud rate. The ISP  
firmware provides auto-echo of received characters.  
The ISP facility was designed to that specific crystal frequencies  
were not required in order to generate baud rates or time the  
programming pulses. The user thus needs to provide the  
89C51RB2/RC2/RD2 with information required to generate the  
proper timing. Record type 02 is provided for this purpose.  
Once baud rate initialization has been performed, the ISP firmware  
will only accept Intel Hex-type records. Intel Hex records consist of  
ASCII characters used to represent hexadecimal values and are  
summarized below:  
WinISP, a software utility to implement ISP programming with a PC,  
is available from Philips. Commercial serial ISP programmers are  
available from third parties. Please check the Philips web site  
(www.semiconductors.philips.com) for additional information.  
:NNAAAARRDD..DDCC<crlf>  
In the Intel Hex record, the “NN” represents the number of data  
bytes in the record. The 89C51RB2/RC2/RD2 will accept up to 16  
(10H) data bytes. The “AAAA” string represents the address of the  
41  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Table 8. Intel-Hex Records Used by In-System Programming  
RECORD TYPE  
COMMAND/DATA FUNCTION  
00  
Program Data  
:nnaaaa00dd....ddcc  
Where:  
Nn  
Aaaa  
= number of bytes (hex) in record  
= memory address of first byte in record  
dd....dd = data bytes  
cc  
= checksum  
Example:  
:10008000AF5F67F0602703E0322CFA92007780C3FD  
01  
02  
End of File (EOF), no operation  
:xxxxxx01cc  
Where:  
xxxxxx  
cc  
= required field, but value is a “don’t care”  
= checksum  
Example:  
:00000001FF  
Specify Oscillator Frequency  
:01xxxx02ddcc  
Where:  
xxxx  
dd  
cc  
= required field, but value is a “don’t care”  
= integer oscillator frequency rounded down to nearest MHz  
= checksum  
Example:  
:0100000210ED  
(dd = 10h = 16, used for 16.0–16.9 MHz)  
42  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
RECORD TYPE  
COMMAND/DATA FUNCTION  
03  
Miscellaneous Write Functions  
:nnxxxx03ffssddcc  
Where:  
nn  
xxxx  
03  
= number of bytes (hex) in record  
= required field, but value is a “don’t care”  
= Write Function  
ff  
ss  
= subfunction code  
= selection code  
dd  
cc  
= data input (as needed)  
= checksum  
Subfunction Code = 01 (Erase Blocks)  
ff = 01  
ss = block code as shown below:  
block 0, 0k to 8k, 00H  
block 1, 8k to 16k, 20H  
block 2, 16k to 32k, 40H  
block 3, 32k to 48k, 80H  
block 4, 48k to 64k, C0H  
Example:  
:0200000301C03A erase block 4  
Subfunction Code = 04 (Erase Boot Vector and Status Byte)  
ff = 04  
ss = don’t care  
dd = don’t care  
Example:  
:020000030400F7 erase boot vector and status byte  
Subfunction Code = 05 (Program Security Bits)  
ff = 05  
ss = 00 program security bit 1 (inhibit writing to Flash)  
01 program security bit 2 (inhibit Flash verify)  
02 program security bit 3 (disable eternal memory)  
Example:  
:020000030501F5 program security bit 2  
Subfunction Code = 06 (Program Status Byte or Boot Vector)  
ff = 06  
ss = 00 program status byte  
01 program boot vector  
Example:  
:030000030601FCF7 program boot vector with 0FCH  
Subfunction Code = 07 (Full Chip Erase)  
Erases all blocks, security bits, and sets status and boot vector to default values  
ff = 07  
ss = don’t care  
dd = don’t care  
Example:  
:0100000307F5 full chip erase  
04  
Display Device Data or Blank Check – Record type 04 causes the contents of the entire Flash array to be sent out  
the serial port in a formatted display. This display consists of an address and the contents of 16 bytes starting with that  
address. No display of the device contents will occur if security bit 2 has been programmed. The dumping of the device  
data to the serial port is terminated by the reception of any character.  
General Format of Function 04  
:05xxxx04sssseeeeffcc  
Where:  
05  
xxxx  
04  
ssss  
eeee  
ff  
= number of bytes (hex) in record  
= required field, but value is a “don’t care”  
= “Display Device Data or Blank Check” function code  
= starting address  
= ending address  
= subfunction  
00 = display data  
01 = blank check  
= checksum  
cc  
Example:  
:0500000440004FFF0069 display 4000–4FFF  
43  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
RECORD TYPE  
COMMAND/DATA FUNCTION  
05  
Miscellaneous Read Functions  
General Format of Function 05  
:02xxxx05ffsscc  
Where:  
02  
xxxx  
05  
=
=
=
=
number of bytes (hex) in record  
required field, but value is a “don’t care”  
“Miscellaneous Read” function code  
ffss  
subfunction and selection code  
0000 = read signature byte – manufacturer id (15H)  
0001 = read signature byte – device id # 1  
0002 = read signature byte – device id # 2  
(C2H)  
0700 = read security bits  
0701 = read status byte  
0702 = read boot vector  
cc  
= checksum  
Example:  
:020000050001F8 read signature byte – device id # 1  
06  
Direct Load of Baud Rate  
General Format of Function 06  
:02xxxx06hhllcc  
Where:  
02  
xxxx  
06  
hh  
ll  
=
=
=
=
=
=
number of bytes (hex) in record  
required field, but value is a “don’t care”  
”Direct Load of Baud Rate” function code  
high byte of Timer 2  
low byte of Timer 2  
checksum  
cc  
Example:  
:02000006F50003  
44  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
the microcontroller’s registers before making a call to PGM_MTP at  
FFF0H. The oscillator frequency is an integer number rounded down  
to the nearest megahertz. For example, set R0 to 11 for 11.0592 MHz.  
Results are returned in the registers. The API calls are shown in  
Table 9.  
In Application Programming Method  
Several In Application Programming (IAP) calls are available for use by  
an application program to permit selective erasing and programming of  
Flash sectors. All calls are made through a common interface,  
PGM_MTP. The programming functions are selected by setting up  
Table 9. IAP calls  
IAP CALL  
PARAMETER  
PROGRAM DATA BYTE  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 02h  
DPTR = address of byte to program  
ACC = byte to program  
Return Parameter  
ACC = 00 if pass, !00 if fail  
ERASE BLOCK  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 01h  
DPH = block code as shown below:  
block 0, 0k to 8k, 00H  
block 1, 8k to 16k, 20H  
block 2, 16k to 32k, 40H  
block 3, 32k to 48k, 80H  
block 4, 48k to 64k, C0H  
DPL = 00h  
Return Parameter  
none  
ERASE BOOT VECTOR  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 04h  
DPH = 00h  
DPL = don’t care  
Return Parameter  
none  
PROGRAM SECURITY BIT  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 05h  
DPH = 00h  
DPL = 00h – security bit # 1 (inhibit writing to Flash)  
01h – security bit # 2 (inhibit Flash verify)  
02h – security bit # 3 (disable external memory)  
Return Parameter  
none  
PROGRAM STATUS BYTE  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 06h  
DPH = 00h  
DPL = 00h – program status byte  
ACC = status byte  
Return Parameter  
ACC = status byte  
PROGRAM BOOT VECTOR  
Input Parameters:  
R0 = osc freq (interger)  
R1 = 06h  
DPH = 00h  
DPL = 01h – program boot vector  
ACC = boot vector  
Return Parameter  
ACC = boot vector  
READ DEVICE DATA  
Input Parameters:  
R1 = 03h  
DPTR = address of byte to read  
Return Parameter  
ACC = value of byte read  
45  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
IAP CALL  
PARAMETER  
READ MANUFACTURER ID  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 00h  
DPH = 00h  
DPL = 00h (manufacturer ID)  
Return Parameter  
ACC = value of byte read  
READ DEVICE ID # 1  
READ DEVICE ID # 2  
READ SECURITY BITS  
READ STATUS BYTE  
READ BOOT VECTOR  
FULL CHIP ERASE  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 00h  
DPH = 00h  
DPL = 01h (device ID # 1)  
Return Parameter  
ACC = value of byte read  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 00h  
DPH = 00h  
DPL = 02h (device ID # 2)  
Return Parameter  
ACC = value of byte read  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 07h  
DPH = 00h  
DPL = 00h (security bits)  
Return Parameter  
ACC = value of byte read  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 07h  
DPH = 00h  
DPL = 01h (status byte)  
Return Parameter  
ACC = value of byte read  
Input Parameters:  
R0 = osc freq (integer)  
R1 = 07h  
DPH = 00h  
DPL = 02h (boot vector)  
Return Parameter  
ACC = value of byte read  
Input Parameters:  
R0 = osc frequency  
R1 = 08h  
DPH = don’t care  
DPL = don’t care  
Return Parameter  
none  
46  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Security  
The security feature protects against software piracy and prevents  
the contents of the Flash from being read. The Security Lock bits  
are located in Flash. The 89C51RB2/RC2/RD2 has 3 programmable  
security lock bits that will provide different levels of protection for the  
on-chip code and data (see Table 10).  
Table 10.  
1
SECURITY LOCK BITS  
PROTECTION DESCRIPTION  
LB1  
LB2  
LB3  
X
X
X
MOVC instructions executed from external program memory are disabled from fetching code bytes  
from internal memory.  
1
X
X
X
1
X
X
1
Block erase is disabled. Erase or programming of the status byte or boot vector is disabled.  
Verify of code memory is disabled.  
X
External execution is disabled.  
NOTE:  
1. Security bits are independent of each other. Full-chip erase may be performed regardless of the state of the security bits.  
47  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
DIP40: plastic dual in-line package; 40 leads (600 mil)  
SOT129-1  
48  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
PLCC44: plastic leaded chip carrier; 44 leads  
SOT187-2  
49  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
QFP44: plastic quad flat package; 44 leads (lead length 1.3 mm); body 10 x 10 x 1.75 mm  
SOT307-2  
50  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
NOTES  
51  
1999 Sep 23  
Philips Semiconductors  
Preliminary specification  
80C51 8-bit Flash microcontroller family  
16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM  
89C51RB2/89C51RC2/  
89C51RD2  
Data sheet status  
[1]  
Data sheet  
status  
Product  
status  
Definition  
Objective  
specification  
Development  
This data sheet contains the design target or goal specifications for product development.  
Specification may change in any manner without notice.  
Preliminary  
specification  
Qualification  
This data sheet contains preliminary data, and supplementary data will be published at a later date.  
Philips Semiconductors reserves the right to make changes at any time without notice in order to  
improve design and supply the best possible product.  
Product  
specification  
Production  
This data sheet contains final specifications. Philips Semiconductors reserves the right to make  
changes at any time without notice in order to improve design and supply the best possible product.  
[1] Please consult the most recently issued datasheet before initiating or completing a design.  
Definitions  
Short-form specification — The data in a short-form specification is extracted from a full data sheet with the same type number and title. For  
detailed information see the relevant data sheet or data handbook.  
Limiting values definition — Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one  
or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or  
at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended  
periods may affect device reliability.  
Application information — Applications that are described herein for any of these products are for illustrative purposes only. Philips  
Semiconductors make no representation or warranty that such applications will be suitable for the specified use without further testing or  
modification.  
Disclaimers  
Life support — These products are not designed for use in life support appliances, devices or systems where malfunction of these products can  
reasonably be expected to result in personal injury. Philips Semiconductors customers using or selling these products for use in such applications  
do so at their own risk and agree to fully indemnify Philips Semiconductors for any damages resulting from such application.  
RighttomakechangesPhilipsSemiconductorsreservestherighttomakechanges, withoutnotice, intheproducts, includingcircuits,standard  
cells, and/or software, described or contained herein in order to improve design and/or performance. Philips Semiconductors assumes no  
responsibility or liability for the use of any of these products, conveys no license or title under any patent, copyright, or mask work right to these  
products, and makes no representations or warranties that these products are free from patent, copyright, or mask work right infringement, unless  
otherwise specified.  
Philips Semiconductors  
811 East Arques Avenue  
P.O. Box 3409  
Copyright Philips Electronics North America Corporation 1999  
All rights reserved. Printed in U.S.A.  
Sunnyvale, California 94088–3409  
Telephone 800-234-7381  
Date of release: 09-99  
Document order number:  
9397–750–06427  
Philips  
Semiconductors  

相关型号:

P89C51RD2HBA/00

IC 8-BIT, FLASH, 33 MHz, MICROCONTROLLER, PQCC44, PLASTIC, LCC-44, Microcontroller
NXP

P89C51RD2HBB

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM
NXP

P89C51RD2HBBD

80C51 8-bit Flash microcontroller family
NXP

P89C51RD2HBP

80C51 8-bit Flash microcontroller family
NXP

P89C51RD2HBP/00

IC 8-BIT, FLASH, 33 MHz, MICROCONTROLLER, PDIP40, PLASTIC, DIP-40, Microcontroller
NXP

P89C51RD2HFA

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM
NXP

P89C51RD2HFB

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM
NXP

P89C51RD2HFP

80C51 8-bit Flash microcontroller family 16KB/32KB/64KB ISP/IAP Flash with 512B/512B/1KB RAM
NXP

P89C51RD2HXX

80C51 8-bit Flash microcontroller family
NXP

P89C51UBAA

80C51 8-bit microcontroller family 4K/8K/16K/32K Flash
NXP

P89C51UBAA-T

Microcontroller, 8-Bit, FLASH, 8051 CPU, 33MHz, CMOS, PQCC44,
PHILIPS

P89C51UBBB

80C51 8-bit microcontroller family 4K/8K/16K/32K Flash
NXP