HS13Z-D [NKK]

Rotary Switch, 4 Positions, SP4T, Latched, 5A, 30VDC, Solder Terminal, D Flat Shaft Type Actuator, Panel Mount-threaded;
HS13Z-D
型号: HS13Z-D
厂家: NIHON KAIHEIKI INDUSTRY CO. LTD.    NIHON KAIHEIKI INDUSTRY CO. LTD.
描述:

Rotary Switch, 4 Positions, SP4T, Latched, 5A, 30VDC, Solder Terminal, D Flat Shaft Type Actuator, Panel Mount-threaded

开关
文件: 总5页 (文件大小:247K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Standard Size Rotaries Series HS TS PS  
GENERAL SPECIFICATIONS  
Electrical Capacity  
Other Ratings  
Resistive Load: HS13: 6A @ 125V AC, 3A @ 250V AC, or 5A @ 30V DC  
HS16: 12A @ 125V AC or 6A @ 250V AC  
TS: 6A @ 125/250V AC  
PS: 30A @ 125/250V AC  
Contact Resistance: 10 milliohms maximum  
Insulation Resistance: 200 megohms minimum @ 500V DC  
Dielectric Strength: 1,500V AC minimum for 1 minute minimum  
Mechanical Life: HS: 15,000 operations minimum  
TS: 30,000 operations minimum  
PS: 10,000 operations minimum  
Electrical Life: HS: 7,500 operations minimum  
TS: 10,000 operations minimum  
PS: 5,000 operations minimum  
Indexing: 30° for HS16, TS & PS; 45° for HS13  
Contact Timing: Nonshorting HS13; Shorting & Nonshorting HS16; Nonshorting TS; Nonshorting PS  
Range of Operating Torque: HS16: 0.54 ~ 0.64Nm for first pole & 0.05Nm for each additional pole  
HS13: 0.15 ~ 0.24Nm  
TS: 0.09Nm for first pole & (0.07Nm x total number of poles) + 0.13Nm for additional poles  
PS: 0.14Nm for each pole  
Materials & Finishes  
Knob: Phenolic resin  
Shaft: HS13: brass; HS16, TS, & PS: brass with nickel plating  
Bushing: HS13: brass; HS16, TS, & PS: brass with nickel plating  
Case: Phenolic resin  
Movable Contacts: HS13, HS16, & TS phosphor bronze; PS silver alloy  
Stationary Contacts: HS13, HS16, & PS: brass with silver plating; TS: phosphor bronze  
Terminals: HS: phosphor bronze; TS & PS: copper with silver plating  
Environmental Data  
Operating Temp Range:  
–10°C through +70°C (+14°F through +158°F)  
Humidity: 90 ~ 98% humidity for 96 hours @ 40°C (104°F)  
Vibration: 10 ~ 55 Hz with peak-to-peak amplitude of 1.5mm traversing the frequency range  
& returning in 1 minute; 3 right angled directions for 2 hours  
2
Shock: 50G (490m/s ) acceleration (tested in 3 right angled directions, with 3 shocks in each direction)  
Installation  
Mounting Torque:  
2.94Nm (26 lbin)  
Maximum Panel Thickness: Shown with panel cutouts in following drawings  
Soldering Time & Temperature: Manual Soldering (HS series only): See Profile A in Supplement section.  
Standards & Certifications  
UL Recognized: HS16 models 1– through 6–pole are recognized at 12A @ 125V AC & 6A @ 250V AC  
See Supplement section to find UL rating details. UL File No. WOYR2.E44145  
Add “/U” to end of part number to order UL mark on switch.  
C-UL Recognized: HS16 models 1– through 6–pole are recognized at 12A @ 125V AC & 6A @ 250V AC  
R
See Supplement section to find C-UL rating details. UL File No. WOYR8.E44145  
Add “/C-UL” to end of part number to order UL mark on switch.  
3-07  
www.nikkaiswitches.com • Nihon Kaiheiki • Phone 81-44-813-8008 • Fax 81-44-813-8038  
Standard Size Rotaries Series HS  
6 AMP SINGLE POLE/NONSHORTING/45° INDEXING  
Schematics  
Round  
Shaft  
D-flat  
Shaft  
Number of  
Positions  
Stopper  
Settings  
Number of  
Terminals  
Load  
Terminals  
C
of Keyway  
C
of Keyway  
C of Keyway  
L
L
L
HS13X  
HS13Y  
HS13Z  
3
3
HS13X  
HS13Y  
HS13Z  
HS13X-D  
HS13Y-D  
HS13Z-D  
2
3
4
Fixed  
Fixed  
Fixed  
1 COM, 2 LOAD  
1 COM, 3 LOAD  
1 COM, 4 LOAD  
1 & 2  
2
2
2
4
1, 2, & 3  
1, 2, 3, & 4  
1
1
1
C
1
C
1
C
1
Switch is viewed from shaft end and shown in position 1. Terminal numbers are not on switch. Standard Hardware shown on last page of this section.  
(0.7) Typ  
.028  
M10 P0.75  
Keyway  
4
(10.3) Dia  
.406  
3
(10.5) Dia  
.413  
(6.0) Dia  
.236  
(9.5)  
.374  
2
(9.0)  
.354  
(1.5)  
.059  
1
(3.0) Dia  
.118  
(0.3)  
.012  
(16.0)  
.630  
(5.7) Typ  
.224  
COM  
Maximum Effective Panel Thickness  
With Locking Ring  
(10.0) (10.0)  
.394 .394  
(4.8) Typ  
.189  
.150” (3.8mm)  
Without Locking Ring  
.189” (4.8mm)  
(40.0)  
1.575  
(2.6) Dia Typ  
.102  
(34.0) Dia  
1.339  
HS13X  
12 AMP/SHORTING & NONSHORTING/30° INDEXING  
Knurled Shaft  
D-flat Shaft  
Number of  
Positions  
Stopper  
Settings  
Number of  
Terminals  
Nonshorting  
Shorting  
HS16-1S  
HS16-2S  
HS16-3S  
HS16-4S  
HS16-5S  
HS16-6S  
Nonshorting  
HS16-1N  
HS16-2N  
HS16-3N  
HS16-4N  
HS16-5N  
HS16-6N  
Shorting  
Pole  
1P  
2P  
3P  
4P  
5P  
6P  
Schematic  
C
HS16-1  
HS16-2  
HS16-3  
HS16-4  
HS16-5  
HS16-6  
HS16-1SN  
HS16-2SN  
HS16-3SN  
HS16-4SN  
HS16-5SN  
HS16-6SN  
2-11  
2-11  
2-11  
2-11  
2-11  
2-11  
2, 3, 4 . . . 11 1 COM, 11 LOAD  
2, 3, 4 . . . 11 2 COM, 22 LOAD  
2, 3, 4 . . . 11 3 COM, 33 LOAD  
2, 3, 4 . . . 11 4 COM, 44 LOAD  
2, 3, 4 . . . 11 5 COM, 55 LOAD  
2, 3, 4 . . . 11 6 COM, 66 LOAD  
1
1
11  
2
10  
9
3
C
of Keyway  
L
4
5
8
6
7
Keyway  
M10 P0.75  
(6.0) Dia  
.236  
(65.0)  
2.559  
(8.0) Typ  
.315  
(4.4)  
.173  
(10.0)  
.394  
(24.5)  
.965  
(34.5)  
1.358  
(0.84) Typ  
.033  
(55.0)  
2.165  
(44.5)  
1.752  
(2.6) Dia Typ  
.102  
(6.24) Typ  
.246  
(54.5)  
2.146  
(64.5)  
2.539  
(10.3) Dia  
.406  
(15.0) (14.0)  
.591  
.551  
(74.5)  
2.933  
(7.0) Max  
.276  
(10.5) Dia  
.413  
(9.5)  
.374  
(9.0)  
.354  
• On each deck of multipole devices common and load terminals  
are in the same positions as shown in the schematic above.  
(1.5)  
.059  
(3.0) Dia  
.118  
• Switch is viewed from the shaft end and shown in position 1.  
Maximum Effective Panel Thickness  
With Locking Ring  
Terminal numbers are on the switch bottom. Stopper positions  
are molded on the top of the switch.  
.189” (4.8mm)  
Without Locking Ring  
.228” (5.8mm)  
• Standard Hardware shown on last page of this section.  
HS16-2N  
3-07  
www.nikkaiswitches.com • Nihon Kaiheiki • Phone 81-44-813-8008 • Fax 81-44-813-8038  
Standard Size Rotaries Series TS  
6 AMP/NONSHORTING/ADJUSTABLE STOP/30° INDEXING  
Number of  
Positions  
Stopper  
Settings  
Number of  
Terminals  
Shaft  
Type  
Model  
TS1N  
Pole  
Schematic  
C
of Keyway  
L
C
1
1
1P  
2-11  
2-11  
2-11  
2-11  
2-11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
1 COM, 11 LOAD  
2 COM, 22 LOAD  
3 COM, 33 LOAD  
4 COM, 44 LOAD  
5 COM, 55 LOAD  
D Flat  
D Flat  
D Flat  
D Flat  
D Flat  
2
11  
3
4
10  
9
TS2N  
TS3N  
TS4N  
TS5N  
2P  
3P  
4P  
5P  
5
8
6
7
On each deck of multipole devices common  
& load terminals are in the same positions  
as shown in this schematic.  
Switch is viewed from the shaft end and  
shown in position 1.  
Terminal numbers are on the switch bottom.  
Stopper positions are molded on the top of  
the switch.  
• Standard Hardware shown on last page of this section.  
Top  
Bottom  
Panel Cutouts  
Keyway  
(10.3) Dia  
.406  
(10.5) Dia  
.413  
(9.5)  
.374  
(9.0)  
.354  
(1.5)  
.059  
(4.4)  
.173  
(3.0) Dia  
.118  
Maximum Effective Panel Thickness  
With Locking Ring  
.189” (4.8mm)  
Without Locking Ring  
.228” (5.8mm)  
(42.0) Dia  
1.654  
(44.0) Dia  
1.732  
M3 x 4 Typ  
M10 P0.75  
(6.0) Dia  
.236  
(22.0)  
.866  
(13.0)  
.512  
(34.0)  
1.339  
(46.0)  
1.811  
(58.0)  
2.283  
(15.6)  
.614  
(14.0)  
.551  
(70.0)  
2.756  
TS5N  
3-07  
www.nikkaiswitches.com • Nihon Kaiheiki • Phone 81-44-813-8008 • Fax 81-44-813-8038  
Standard Size Rotaries Series PS  
30 AMP/NONSHORTING/ADJUSTABLE STOP/30° INDEXING  
Number of  
Positions  
Stopper  
Settings  
Number of  
Terminals  
Knurled  
Shaft  
D Flat  
Shaft  
Pole  
Schematic  
C
of Keyway  
1
L
PS1  
PS2  
PS3  
PS4  
PS5  
PS1N  
PS2N  
PS3N  
PS4N  
PS5N  
1P  
2-11  
2-11  
2-11  
2-11  
2-11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
2, 3, 4 . . . 11  
1 COM, 11 LOAD  
2 COM, 22 LOAD  
3 COM, 33 LOAD  
4 COM, 44 LOAD  
5 COM, 55 LOAD  
C
1
2P  
3P  
4P  
5P  
2
11  
3
4
10  
9
5
8
6
7
On each deck of multipole devices common & load terminals are in the same positions as shown in this schematic. Switch is viewed from  
the shaft end and shown in position 1. Terminal numbers are on switch bottom. Stopper positions are molded on the top of the switch.  
• Standard Hardware shown on last page of this section.  
Panel Cutout  
Top  
Bottom  
(4.4)  
.173  
(4.5) Dia Typ  
.177  
(10.5) Dia  
.413  
(9.0)  
.354  
(3.0) Dia  
.118  
(20.0) R  
.787  
(40.0) Dia  
1.575  
Maximum Effective Panel Thickness  
Without Locking Ring  
M4  
.189” (4.8mm)  
(76.0) Dia  
2.992  
(70.0) Dia  
2.756  
M4 x 5 Typ  
M10 P0.75  
Keyway  
(6.0) Dia  
.236  
(10.0)  
.394  
(7.0)  
.276  
(24.5)  
.965  
(42.0)  
1.654  
(59.5)  
2.343  
(15.0)  
.591  
(77.0)  
3.031  
(29.0)  
1.142  
(94.5)  
3.720  
(15.0) Max  
.591  
PS4N  
3-07  
www.nikkaiswitches.com • Nihon Kaiheiki • Phone 81-44-813-8008 • Fax 81-44-813-8038  
Standard Size Rotaries Series HS TS PS  
SHAFT TYPES  
D Flat Shaft  
Knurled Shaft  
(6.0) Dia  
.236  
(6.0) Dia  
.236  
For use with  
AT431 and AT432  
Not for use with  
AT431 or AT432  
(4.4)  
.173  
(13.0)  
.512  
(20.0)  
.787  
(15.0)  
.591  
OPTIONAL KNOBS FOR D FLAT SHAFTS  
AT431  
Large Knob  
AT432  
Small Knob  
Knob Orientation  
The rotary  
knobs used  
on the D-flat  
shafts can  
be oriented  
on the switch  
to suit the  
customers  
particular  
front panel  
needs simply  
by sliding the  
knob over  
Phenolic Resin  
Phenolic Resin  
Assembly Screw  
(19.5)  
.768  
(15.6)  
.614  
Black only  
with white  
indicator  
Black only  
with white  
indicator  
(21.0)  
.827  
(24.0)  
.945  
line  
line  
(57.0)  
2.244  
(41.0)  
1.614  
(25.0) Dia  
.984  
(30.0) Dia  
1.181  
Set Screw  
Adaptor  
Shaft  
(5.5)  
.217  
(5.5)  
.217  
(24.0)  
.945  
(21.0)  
.827  
the square  
adaptor at  
the preferred  
orientation.  
(9.0)  
.354  
(9.0)  
.354  
(29.0)  
1.142  
(28.0)  
1.102  
(21.0)  
.827  
(20.0)  
.787  
M2.3 x 0.4 x 0.8  
M2.3 x 0.4 x 0.8  
STOPPER SETTING  
For HS16, TS, & PS Models  
AT526  
AT518  
The HS16, TS, and PS switches are supplied with the stopper plate set for the  
maximum number of positions allowed for that model. Prior to installation,  
the desired stopper setting should be made:  
AT520  
AT526  
1. Be sure the shaft is turned counterclockwise to the extreme left. If the  
shaft is not turned counterclockwise to the extreme left, proper setting  
cannot be achieved.  
AT526  
2. Loosen the nut far enough to allow raising the stopper plate for resetting.  
3. Insert the stopper in the numbered hole for the desired stopper setting.  
Satisfactory switch functioning cannot be assured if the stopper plate is  
not properly positioned.  
4. Tighten the nut firmly against the stopped plate.  
Standard Hardware Supplied with HS, TS, and PS:  
AT526 Hex Mounting Nut (quantity 3)  
AT518 Locking Ring (quantity 1)  
AT520 Split Lockwasher (quantity 1)  
Use of mounting supports on PS is optional; screws are not provided.  
3-07  
www.nikkaiswitches.com • Nihon Kaiheiki • Phone 81-44-813-8008 • Fax 81-44-813-8038  

相关型号:

HS14

HIGH EFFICIENCY RECTIFIERS(1.0A,50-400V)
MOSPEC

HS14

14 pin Dual-in-line Sine Wave Clock Oscillators
EUROQUARTZ

HS14

HIGH RELIABILITY FOR LOW COST
PETERMANN

HS1400-200MHZ

Peripheral IC
ETC

HS1400-63MHZ

Peripheral IC
ETC

HS1400-SERIES

Peripheral IC
ETC

HS1401-200MHZ

Peripheral IC
ETC

HS1401-63MHZ

Peripheral IC
ETC

HS1401-SERIES

Peripheral IC
ETC

HS1402-200MHZ

Peripheral IC
ETC

HS1402-63MHZ

Peripheral IC
ETC

HS1402-SERIES

Peripheral IC
ETC