S Series Multifunction DAQ  
16-Bit, 250 kS/s/Channel, 8 Analog Inputs  
NI 6143  
• 8 differential 16-bit analog inputs  
• 250 kS/s per channel analog input  
• Simultaneous sampling  
• 8 digital I/O lines  
Recommended Software  
• LabVIEW 7.x or higher  
• LabWindows/CVI 7.x or higher  
• Measurement Studio 7.x or higher  
• SignalExpress 1.x or higher  
(5 V TTL/CMOS);  
two 24-bit counter/timers  
• Digital triggering  
Other Compatible Software  
• VI Logger 2.x or higher  
• Visual Studio .NET  
5 V analog input signal range  
• Measurement services that simplify  
configuration and measurements  
• Visual Basic, C/C++, and C#  
Measurement Services  
Software (included)1  
Operating Systems  
• Windows 2000/NT/XP  
• Mac OS X  
• NI-DAQmx driver  
• Measurement & Automation  
Explorer configuration utility  
• VI Logger Lite data-logging software  
1Mac OS X and Linux applications  
must use NI-DAQmx Base driver software.  
• Linux  
Calibration Certificate Available  
Family  
NI 6143  
Bus  
PCI, PXI  
Analog Inputs  
Input Resolution  
Sampling Rate  
250 kS/s per channel  
Input Range  
Digital I/O  
Counter/ Timers  
2, 24-bit  
Trigger  
Digital  
8
16 bits  
5 ꢀ  
8
Table 1. Channel, Speed, and Resolution Specifications  
Overview and Applications  
Better Dynamic Specifications – Because each channel has a  
National Instruments 6143 devices combine the latest in PC dedicated ADC, there is less concern with settling time and the noise  
technologies to deliver simultaneous sampling for high-channel- and error caused by switching input channels. You can tune the  
count applications at a low cost. Use these devices in a variety of analog input path for both accurate DC and dynamic measurements.  
applications, including:  
Traditional data acquisition devices are ideal for DC measurements,  
but are not always the best solution for dynamic measurements.  
• High-energy physics  
• Ultrasonic and sonar testing  
• Ballistics and highly transient signals  
• Multiaxis control  
Low-Cost – The decrease in price of ADCs over time has made a  
dedicated ADC per channel architecture cost-effective.  
Features  
These devices fall into the NI S Series product family. The S stands for  
simultaneous sampling, the most evident benefit of the dedicated  
analog-to-digital converter (ADC) per channel architecture. However,  
the architecture has a few less obvious but very important advantages.  
Ordering Information  
NI PCI-6143 ..................................................................778913-01  
NI PXI-6143 ..................................................................779063-01  
Includes data acquisition driver software.  
BUY NOW!  
Dedicated ADCs per Channel – This architecture offers a much  
higher sampling rate per channel. Traditional data acquisition  
devices share the sampling rate among the number of active  
channels. The overall data throughput stays the same. With S Series  
devices, the aggregate throughput increases with the number of  
active channels.  
For complete product specifications, pricing, and accessory  
information, call (800) 813 3693 (U.S. only) or go to  
ni.com/dataacquisition.  
S Series Multifunction DAQ  
16-Bit, 250 kS/s/Channel, 8 Analog Inputs  
Multichannel Control  
NI Spectral Measurements Toolkit  
For applications that require multichannel simultaneous control, This toolkit includes all of the analysis and presentation tools to  
such as multiaxis control systems, an NI 6143 paired with an convert your S Series device into a full-featured spectrum analyzer.  
NI 6733 analog output device is a low-cost, high-performance The toolkit includes:  
control solution. When coupled together with LabVIEW Real-Time, • Measurements such as in-band power and adjacent-channel power  
these devices are capable of deterministic performance at speeds • 3D spectrogram  
exceeding 20 kHz for eight parallel PID loops. This control system • Analog modulation and demodulation  
architecture effectively meets today’s demands but also grows with • I-Q data for digital demodulation  
future requirements. As your control algorithms change, you can • Highly optimized FFT processing  
implement simple to advanced control strategies in LabVIEW Real-  
Time without breaking the connection to your I/O. Furthermore, as  
your system I/O requirements change, simply add more I/O to the  
existing system without significantly modifying your control code.  
Professional Analysis and  
Presentation Toolkits  
There are several analysis and presentation add-on toolkits available  
from National Instruments that help make you more productive  
when developing custom applications with your S Series devices.  
Turn your S Series device into a transient recorder, spectrum analyzer,  
or one of several other instruments with these toolkits.  
NI LabVIEW Sound and Vibration Toolkit  
This toolkit includes a full set of frequency-domain analysis and  
presentation tools required for sound and vibration applications.  
Figure 1. Sound and Vibration Toolkit  
These tools include:  
• Distortion, gain, phase, cross-talk, and dynamic range measurements  
• Octave analysis  
High-Performance Data Throughput  
Using NI-DAQmx driver software and S Series, you can take full  
advantage of your PC’s throughput potential, which is useful in many  
applications including transient recording.  
• Swept-sine analysis  
• Linear, exponential and peak hold measurements  
• Baseband and zoom FFT, power, FFT, power spectral density (PSD)  
• Limit testing  
• Short-time Fourier transform and shock response spectrum  
Weighting filters  
Flexible Data Transfer  
With NI-DAQmx, you can choose where to accumulate data – on the  
onboard memory, PC RAM memory, or PC hard drive memory.  
Thus, you can balance your PC application requirements and  
stream-to-disk/memory capabilities. In any case, NI-DAQmx  
optimizes data transfers by using DMA (direct memory access) and  
• System calibration  
Waterfall/colormap display  
NI LabVIEW Signal Processing Toolkit  
This toolkit is a suite of software tools, example programs, and transferring large chunks of data, while ensuring no data loss. You  
utilities for time-frequency analysis and digital filter design. The can also choose the format of your data, further optimizing  
toolkit includes:  
throughput. Choices include raw (binary), scaled, or the high-level  
waveform data type. Using these techniques, you can achieve rates of  
more than 40 MS/s sustained over the PCI/PXI bus to hard drive  
(depending on the PC).  
Wavelet and filter-bank design  
• Digital filter design of FIR and IIR filters  
• Joint time-frequency analysis (JTFA) with the Gabor spectrograph  
• High-frequency resolution model-based spectral estimation for  
small datasets  
2
National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com  
S Series Multifunction DAQ  
16-Bit, 250 kS/s/Channel, 8 Analog Inputs  
Cleaner Code Development – Basic and advanced software  
Data Compaction  
With the release of NI-DAQmx 7.4 or later, data compaction functions have been combined into one easy-to-use yet powerful  
is available for stream-to-disk applications. The NI-DAQmx set to help you build cleaner code and move from basic to advanced  
compaction feature strips unused or unwanted bits of data from applications without replacing functions.  
each sample taken from your S Series device before it is permanently  
recorded to hard disk. This is helpful because hard drives are High-Performance Driver Engine – NI-DAQ delivers maximum I/O  
typically the throughput bottleneck compared to the PCI/PXI bus system throughput with a multithreaded driver.  
and PC RAM memory read/write speed. Using data compression,  
users with standard hard drives can see up to 20 percent higher Test Panels – With the Measurement & Automation Explorer  
throughput when streaming-to-disk.  
configuration utility, you can test all of your device functionality  
before you begin development.  
Signal Conditioning  
With the release of NI-DAQmx 7.4 or later, all S Series devices are Scaled Channels – Easily scale your voltage data into the proper  
compatible with parallel-mode SCXI modules.  
engineering units using the NI-DAQ Measurement Ready virtual  
channels by choosing from a list of common sensors and signals or  
creating your own custom scale.  
Model  
Description  
Channels  
SCXI-1520  
SCXI-1125  
SCXI-1141/2/3  
Universal Strain Gage Input  
Isolation Amplifier  
8-Pole Lowpass Filters  
8
8
8
Data-Logging Software – VI Logger Lite is configuration-based  
Table 2. Most Popular Parallel-Mode SCXI Modules  
software designed specifically for data logging. Features include  
SCXI is limited to 100 kS/s for 16-bit accuracy and 333 kS/s for easy logging and viewing of data, data extraction to Microsoft  
12-bit accuracy when used in multiplexed mode. However, in Excel, and code generation in LabVIEW.  
parallel mode, the sample rate is limited by the maximum scan rate  
of the data acquisition device. When SCXI is used in parallel mode LabVIEW Integration – All NI-DAQ functions create the waveform  
with S Series, all channels are simultaneously sampled and the data type, which carries acquired data and timing information  
sample rate is limited by the S Series device, from 250 kS/s per directly into more than 400 LabVIEW built-in analysis routines for  
channel to 10 MS/s per channel.  
display of results in engineering units on a graph.  
Measurement Services Software  
NI-DAQmx Base Driver  
National Instruments measurement services software, built NI-DAQmx Base (available at ni.com/downloads) offers Mac OS X  
around NI-DAQmx driver software, includes intuitive application and Linux users a programming interface similar to NI-DAQmx. It  
programming interfaces, configuration tools, I/O assistants, and includes ready-to-use LabVIEW VIs and C function features similar  
other tools designed to reduce system setup, configuration, and to those included in NI-DAQmx driver software.  
development time. This software is included with your data  
acquisition purchase. Helpful features include:  
Automatic Code Generation – DAQ Assistant is an interactive  
guide that helps you navigate through configuring, testing,  
and programming measurement tasks and generates the  
necessary code automatically for LabVIEW, LabWindows/CVI, or  
Measurement Studio.  
National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com 3  
S Series Multifunction DAQ  
16-Bit, 250 kS/s/Channel, 8 Analog Inputs  
CAL  
Mux  
Address/Data  
DustMITE  
AI 0  
16-Bit  
ADC  
Control  
AI 0  
AI 1  
AI 2  
AI 3  
AI 4  
AI 5  
AI 6  
AI 7  
AI 0 -  
AI 1 +  
AI 1 GND  
AI 2 -  
AI 3 +  
AI 3 GND  
AI 4 +  
AI 4 GND  
AI 5 -  
AI 6 +  
AI 6 GND  
AI 7 -  
NC  
NC  
NC  
P0.4  
D GND  
P0.1  
P0.6  
D GND  
34 68  
33 67  
32 66  
31 65  
30 64  
29 63  
28 62  
27 61  
26 60  
25 59  
24 58  
23 57  
22 56  
21 55  
20 54  
19 53  
18 52  
17 51  
16 50  
15 49  
14 48  
13 47  
12 46  
11 45  
10 44  
AI 0 +  
AI 0 GND  
AI 1 -  
AI 2 +  
AI 2 GND  
AI 3 -  
NC  
AI 4 -  
AI 5 +  
AI 5 GND  
AI 6 -  
AI 7 +  
AI 7 GND  
NC  
NC  
D GND  
P0.0  
P0.5  
D GND  
P0.2  
PGIA  
PGIA  
PGIA  
PGIA  
PGIA  
PGIA  
PGIA  
PGIA  
Address (14)  
Data (32)  
AI 1  
16-Bit  
ADC  
CPLD  
Flash  
AI 2  
16-Bit  
ADC  
AI 3  
16-Bit  
ADC  
FPGA  
AI 4  
16-Bit  
ADC  
STCA  
DMA/IRQ  
+5 V OUTPUT  
D GND  
P0.7  
P0.3  
AI 5  
16-Bit  
ADC  
Analog  
Analog  
Input  
Timing/ Interface  
Control  
Bus  
Output  
Timing/  
Control  
D GND  
AI HOLD COMP  
EXTSTROBE*  
D GND  
PFI 2/AI CONV CLK*  
PFI 3/CTR 1 SOURCE  
PFI 4/CTR 1 GATE  
CTR 1 OUT  
D GND  
PFI 0/AI START TRIG  
PFI 1/AI REF TRIG  
D GND  
DMA/  
DAQ-  
Tigger  
Interface  
Interrupt  
STC  
AI 6  
16-Bit  
ADC  
Interface  
9
8
7
6
5
4
3
2
1
43  
42  
41  
40  
39  
38  
37  
36  
35  
+5 V OUTPUT  
D GND  
Counter/  
Timing  
I/O  
RTSI Bus  
Digital I/O  
Interface  
PFI 5  
PFI 6  
D GND  
AI 7  
16-Bit  
ADC  
PFI 7/AI SAMP CLK  
PFI 8/CTR 0 SOURCE  
D GND  
PFI 9/CTR 0 GATE  
CTR 0 OUT  
FREQ OUT  
RTSI Bus  
PFI/Trigger  
Timing  
D GND  
Digital I/O  
STC DIO  
NC = No Connect  
Figure 2. Block Diagram  
Figure 3. I/O Connector  
4
National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com  
S Series Multifunction DAQ  
Specifications  
The following specifications are typical at 25 °C unless otherwise noted.  
Timing I/O  
Counter/Timers  
Analog Input  
Input Characteristics  
Number of channels......................................... 8 differential  
ADC resolution ................................................. 16 bits, 1 in 65,536  
Sampling rate  
Number of channels .................................. 2 up/down counter/timers  
Resolution.................................................. 24 bits  
Compatibility.............................................. TTL/CMOS  
Digital Trigger  
Maximum................................................... 250 kS/s  
Minimum.................................................... 0 S/s  
Input coupling................................................... DC  
Input range ....................................................... 5 ꢀ  
Input FIFO size .................................................. 2,046 samples  
Data transfers .................................................. DMA, interrupts, programmed I/O  
DMA mode ....................................................... Scatter-gather  
Purpose ............................................................ Start, reference, and pause trigger; sample clock  
External sources............................................... PFI <0..9>, RTSI <0..6>  
Compatibility .................................................... TTL  
Response.......................................................... Rising or falling edge  
Pulse width....................................................... 10 ns min  
RTSI Bus (PCI only)  
Trigger lines <0..6>...........................................  
RTSI clock.........................................................  
7
1
Digital I/O  
Number of channels......................................... 8 input/output  
Compatibility .................................................... TTL/CMOS  
Power-on state ................................................. Input (high-impedance)  
Data transfers .................................................. DMA, interrupts, programmed I/O  
PXI Trigger Bus (PXI only)  
Trigger lines <0..5>...........................................  
Star trigger .......................................................  
Clock.................................................................  
6
1
1
Physical  
Dimensions (not including connectors) ........... 15.5 by 10.6 cm  
(6.10 by 4.17 in.)  
I/O connector.................................................... 68-pin ꢀHDCI  
National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com 5  
S Series Multifunction DAQ  
Cables and Accessories  
Recommended Configurations  
I/O Configuration  
Shielded Option  
Unshielded Option  
BNC Option  
Accessory  
Cable  
SCB-68 (776844-01)  
CB-68LPR (777145-02)  
BNC-2110 (777643-01)  
SHC68-68-EP (186838-01)  
RC68-68 (187252-01)  
SHC68-68-EP (186838-01)  
SHC68-68-EP Noise-Rejecting, Shielded Cable  
This cable connects the NI 6143 devices directly to 68-pin accessories. Latching screws  
secure the shielded connector to the NI 6143. The SHC68-68-EP is a shielded  
68-conductor cable terminated with a VHDCI 68-pin male connector at one end and a  
68-pin female 0.050 series D-type connector at the other.  
SHC68-68-EP Noise-Rejecting, Shielded Cable  
SHC68-68-EP  
0.5 m ..............................................................................................................186838-0R5  
1 m ....................................................................................................................186838-01  
RC68-68 Low-Cost Ribbon Cable  
The RC68-68 cable connects the NI 6143 devices directly to 68-pin accessories.  
0.25 m ..........................................................................................................187252-0R25  
1 m ....................................................................................................................187252-01  
RC68-68 Low-Cost Ribbon Cable  
SCB-68 Noise-Rejecting, Shielded I/O Connector Block  
The SCB-68 is a shielded I/O connector block for rugged, very-low-noise signal  
termination for connecting 68-pin S Series DAQ devices, such as NI 6143. Silk-screened  
component locations provide an easy addition of simple signal-conditioning circuitry for  
your analog input channels. It also includes a general-purpose breadboard area as well as  
an IC temperature sensor for cold-junction compensation in temperature measurements.  
SCB-68 ..............................................................................................................776844-01  
Dimensions – 19.5 by 15.2 by 4.5 cm (7.7 by 6.0 by 1.8 in.)  
CB-68LP and CB-68LPR Low-Cost I/O Connector Blocks  
SCB-68 Noise-Rejecting, Shielded I/O Connector Block  
The CB-68LP and CB-68LPR are low-cost termination accessories with 68 screw  
terminals for easy connection of field I/O signals to 68-pin DAQ devices, such as  
NI 6143. They include one 68-pin male connector for direct connection to 68-pin  
cables. The connector blocks include standoffs for use on a desktop or for mounting  
in a custom panel. The CB-68LP has a vertical-mounted 68-pin connector. The  
CB-68LPR has a right-angle mounted connector, and it is used with the CA-1000.  
CB-68LP............................................................................................................777145-01  
Dimensions – 14.35 by 10.74 cm (5.65 by 4.23 in.)  
CB-68LPR ........................................................................................................777145-02  
Dimensions – 7.62 by 16.19 cm (3.00 by 6.36 in.)  
CB-68LP and CB-68LPR Low-Cost I/O Connector Blocks  
BNC-2110 Noise-Rejecting BNC I/O Connector Block  
The BNC-2110 is a shielded connector block with signal-labeled BNC connectors for  
easy connectivity of your analog input, digital I/O, and counter/timer signals.  
BNC-2110 ........................................................................................................777643-01  
Dimensions – 20.3 by 11.2 by 5.5 cm (8.0 by 4.4 by 2.2 in.)  
BNC-2110 I/O Connector Block  
6
National Instruments • Tel: (800) 813 3693 • info@ni.com • ni.com  
NI Services and Support  
NI has the services and support to meet your  
needs around the globe and through the  
application life cycle – from planning  
and development through deployment  
Local Sales and Technical Support  
In offices worldwide, our staff is local to the country, giving you  
access to engineers who speak your language. NI delivers industry-  
leading technical support through online knowledge bases, our  
applications engineers, and access to 14,000 measurement and  
automation professionals within NI Developer Exchange forums.  
Find immediate answers to your questions at ni.com/support.  
We also offer service programs that provide automatic upgrades to  
your application development environment and higher levels of  
technical support. Visit ni.com/ssp.  
and ongoing maintenance. We offer  
services and service levels to meet  
customer requirements in research,  
design, validation, and manufacturing.  
Visit ni.com/services.  
SERVICE  
NEEDS  
Training and Certification  
NI training is the fastest, most certain route to productivity with our Hardware Services  
products. NI training can shorten your learning curve, save NI Factory Installation Services  
development time, and reduce maintenance costs over the NI Factory Installation Services (FIS) is the fastest and easiest way to  
application life cycle. We schedule instructor-led courses in cities use your PXI or PXI/SCXI combination systems right out of the box.  
worldwide, or we can hold a course at your facility. We also offer a Trained NI technicians install the software and hardware and  
professional certification program that identifies individuals who configure the system to your specifications. NI extends the standard  
have high levels of skill and knowledge on using NI products. warranty by one year on hardware components (controllers, chassis,  
Visit ni.com/training.  
modules) purchased with FIS. To use FIS, simply configure your  
system online with ni.com/pxiadvisor.  
Professional Services  
Our Professional Services Team is comprised of NI applications Calibration Services  
engineers, NI Consulting Services, and a worldwide National Instruments NI recognizes the need to maintain properly calibrated devices for  
Alliance Partner program of more than 600 independent consultants high-accuracy measurements. We provide manual calibration  
and integrators. Services procedures, services to recalibrate your products, and automated  
range from start-up assistance calibration software specifically designed for use by metrology  
to turnkey system integration. laboratories. Visit ni.com/calibration.  
Visit ni.com/alliance.  
Repair and Extended Warranty  
OEM Support  
NI provides complete repair services for our products. Express repair  
We offer design-in consulting and product integration assistance and advance replacement services are also available. We offer  
if you want to use our products for OEM applications. For extended warranties to help you meet project life-cycle requirements.  
information about special pricing and services for OEM customers, Visit ni.com/services.  
visit ni.com/oem.  
ni.com • (800) 813 3693  
National Instruments • info@ni.com  
© 2005 National Instruments Corporation. All rights reserved. CVI, DAQ-STC, LabVIEW, Measurement Ready, Measurement Studio, MITE, National Instruments, National Instruments  
Alliance Partner, NI, ni.com, NI-DAQ, RTSI, SCXI, and SignalExpress are trademarks of National Instruments. Other product and company names listed are trademarks or trade names  
of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.  

相关型号:

779086-006

SUMMENZAEHLER 24VDC
ETC

779087-0M

200 MS/s, 16-Bit Arbitrary Waveform Generator
NI

779096-001

************GESTRICHEN************
ETC

779096-002

SUMMENZAEHLER 230VAC
ETC

779096-007

SUMMENZAEHLER 12VDC
ETC

779096-201

************GESTRICHEN************
ETC

779096-202

SUMMENZAEHLER 230VAC
ETC

779096-206

SUMMENZAEHLER 24VDC
ETC

779096-207

SUMMENZAEHLER 12VDC
ETC

779131-01

24-Bit, 204.8 kS/s Dynamic Signal Acquisition and Generation
NI

779132-01

24-Bit, 204.8 kS/s Dynamic Signal Acquisition and Generation
NI

779145

Telecom IC
IDT